User Manual - ADFWeb.com
Contents
1. Lo Shi Hi V OV E dl a d irs E dl Connector2 J1939 port Isolated port Dip Switch C Dipi 11939 Termination Resistor Dip2 Not used Hi High wire Shl Shield to Isolated Ground V Positive wire Lo Low wire V AC min 8V max 24V iV DC min 12V max 35V Open Figure 2 Connection scheme for HD67215 A1 ADFweb com S r l User Manual 31939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 6 of 29 Industrial Electronic Devices Dip Switch A Dip Switch C Dip1 Must be at ON Dip1 J1939 Termination Resistor Dip2 Functioning mode Dip2 Not used Connector2 311939 port Isolated port Hi High wire Shl Shield to Isolated Ground Lo Low wire See www ADFweb com HD67215 B2 31939 Modbus TCP slave Converter 100 i 31939 port Dip Switeh A Dip 5witeh c Lo Gr Hi o00000000e9Q Connector1 Power Supply port OV Ground V Positive wire V AC min 8V max 24V DC min 12V max 35V Figure 3 Connection scheme for HD67215 B2 ADFweb com S r l User Manual J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 7 of 29 AL Industrial Electronic Devices CHARACTERISTICS The HD67215 A1 and HD67215 B2 are J1939 Modbus TCP slave Converters They have the following characteristics Triple isolation between J1939 Power Supply J1939 Modbus TCP Modbus TCP Power Supply Two directional
2. List of Receive 11933 Frames List of Modbus Registers Create Modify a Modbus Register In the field List of Receive J1939 Frames there is FGN SA Relative to the PGN Selected Index of Modbus Register the list of frames J1939 who you inserted in Receive OxFECA i114 Byte I Byte T 314 a E cuum Uo DANS MEC Pepe nner In the field List of Modbus Registers there is the 0x02BA 117 Byte 7 Byte 8 AE tue Eye tec Parm the Fe list of Modbus registers you have defined for the selected J1939 frame gt In the field Index of Modbus Register insert a Select the Byte to Put in the Low value for the Modbus register Part of the Modbus Register In the field Selecet the Byte to put in the High Byte2 Part of Modbus Register insert which byte of the J1939 frame you want to save in the high part of Modbus register Inthe field Selecet the Byte to put in the Low Part of Modbus Register insert which byte of the J1939 frame you want to save in the low part of Modbus register E Part of the Modbus Register For example Figure 5 Define Receive J1939 window Select one of the J1939 frames you have defined insert a valid address in the field Index of Modbus Register select the byte position Byte 1 in high MODBUS byte and Byte 2 in low MODBUS byte press the Create button In the field List of Modbus Registers appears the modbus register you have defined Note With some Modbus master ther
3. 8 32 64bit When launching the SW67215 the window below appears Fig 2 Note It is necessary to have installed Net Framework 4 5W67 215 31939 Modbus TCP Slave Converter A Opened Configuration of the Converter Begin Examplei Step 1 i New Configuration Open Configuration Step 2 gt Set Communication Step 3 B Receive 31939 E Define 11939 Step 4 B Transmit 11838 B Define J1939 Step 5 3 Update Device www ADFweb com Figure 2 Main window for SW67215 ADFweb com S r l AL User Manual 31939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 14 of 29 Industrial Electronic Devices NEW CONFIGURATION OPEN CONFIGURATION The New Configuration button creates the folder which contains the entire device s configuration SW67215 Create New Configuration Name of the new Configuration A device s configuration can also be imported or exported To clone the configurations of a programmable J1939 Modbus TCP slave Converter in order to configure another device in the same manner it is necessary SW6 72 1 5 to maintain the folder and all its contents Open cm ee ee To clone a project in order to obtain a different version of the project it is sufficient List of Avaliable Configurations to duplicate the project folder with another name and open the new folder with the CAT12M46DF button Open Configuration configurazione 11939 64 71 EngineSimul
4. Phone 39 0438 30 91 31 Fax 39 0438 49 20 99 www adfweb com ADFweb com S r l
5. A1 OLED Ethernet ink EARS HK ES ES D jenen Qn C e Ec CS 07 T CO Ds x awans EH Date Code 31 14 saw wWoHs OO EE ow eo ji t a b o 120 mm 23 mm 4 72 inch 0 9 inch co Housing PVC EE Weight 200g Approx RR e HD67215 B2 31939 Modbus TCP slave Converter 100 Figure 11 Mechanical dimensions scheme for HD67215 A1 iaa 31939 port Dip Switeh A Dip Switeh Lo Gnd Hi oO0o0O0000009Q Q 71 mm 60 mm 2 79 inch 2 36 inch l Housing PVC Figure 12 Mechanical dimensions scheme for HD67215 B2 Weight 200g Approx ADFweb com S r l User Manual J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 27 of 29 AL Industrial Electronic Devices ORDERING INFORMATIONS The ordering part number is formed by a valid combination of the following HD67215 x x L Connectors Type 1 Removable 5mm Screw Terminal 2 Fixed 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting B 4M 35mm DIN Rail mounting Device Family HD67215 J1939 Modbus TCP slave Converter Order Code HD67215 A1 J1939 Modbus TCP slave Converter Order Code HD67215 B2 J1939 Modbus TCP slave Converter ACCESSORIES Order Code AC34001 35mm Rail DIN Power Supply 220 240V AC 50 60Hz 12V AC Order Code AC34002 35mm Rail DIN Power Supply 110V AC 50 60Hz 12 V AC ADFweb com S r l User Manual J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 28
6. A1 or HD67215 B2 device Warning A If Fig 9 appears when you try to do the Update try these points before seeking assistance Try to repeat the operations for the update Try with another PC Try to restart the PC INIT PROTECTION pains If you are using the program inside a Virtual Machine try to use it in the main Operating System If you are using Windows Seven or Vista or 8 make sure that you have the or eee administrator privileges Pay attention to the Firewall lock Check the LAN settings FIRMWARE PROTECTION Figure 9 Protection window A In the case of HD67215 A1 or HD67215 B2 you have to use the software SW67215 www adfweb com download filefold SW677215 zip ADFweb com S r l AL User Manual 391939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 25 of 29 Industrial Electronic Devices UPDATE DEVICE ONLY FOR OLD HW WITH JUMPER By pressing the Update Device button it is possible to load the created configuration into the device and also the Firmware if is necessary This by using the RS232 port Note With this type of update is possible to update only the hardware with jumpers old version no longer sold In order to load the parameters or update the firmware in the device follow these instructions Turn off the Device Connect the RS232 Null Modem cable form your PC to the Converter Insert the Jumper like in the label o
7. Fig 3 In the section Select Device is possible to select the type of device in possess Device from May 2014 with Dip Switch Lal Device till April 2014 with Jumper If is selected Device from May 2014 with Dip Switch the meanings of the fields of J1939 is F F In the fields Baudrate the velocity of J1939 is defined In the field TimeOut Data s insert a time when this time is elapsed the data isn t reliable and in the Modbus register you can read FFFF The field Modbus Reg TimeOut insert a number of register in this register you can visualize if the data is reliable if 1 the data is ok if O the data is oldest of the time inserted in the TimeOut Data field If the field Enable Peer to Peer is cheked the converter accept any ID that have the PGN inserted in the section Receive J1939 In the field Device ID J1939 the J1939 address of the converter is defined If the field Filter FECA ms is checked when the FECA PGN arrives the converter puts the values in Standby If the time expressed in milliseconds and written at the right side of Filter FECA ms is elapsed and there aren t arrived the frames of Transport Protocol the converter put the data of FECA into Modbus Registers Otherwise if the Transport Protocol arrives before the time is elapsed the gateway put his data into Modbus Registers discarding the data of FECA When this field is checked th
8. INDEX INDEX UPDATED DOCUMENTATION REVISION LIST WARNING TRADEMARKS SECURITY ALERT EXAMPLE OF CONNECTION CONNECTION SCHEME CHARACTERISTICS CONFIGURATION POWER SUPPLY FUNCTION MODES LEDS J1939 MODBUS TCP USE OF COMPOSITOR SW67215 NEW CONFIGURATION OPEN CONFIGURATION SOFTWARE OPTIONS SET COMMUNICATION RECIVE J1939 DEFINE RECEIVE J1939 TRANSMIT J1939 DEFINE TRANSMIT J1939 ENABLE REMOTE REQUEST RTR UPDATE DEVICE UPDATE DEVICE ONLY FOR OLD HW WITH JUMPERS MECHANICAL DIMENSIONS ORDERING INFORMATIONS ACCESSORIES DISCLAIMER OTHER REGULATIONS AND STANDARDS WARRANTIES AND TECHNICAL SUPPORT RETURN POLICY ADFweb com S r l OMNNUARAWNNNNNG Oo NNNNKNNKNPKNPKNP SMNPKMSNMNK NN Hd dp pH m HH dH OWODONNUNADAUNUWNKFOUWUADUAWNEHFO User Manual J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 2 of 29 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to web page www adfweb com download and search for the corresponding code on the page Click on the proper Document Code and download the updates REVISION LIST Revision Date Author Chapter Descrip
9. Timer In the field Mnemonic the description for the frame is defined f Note e If is selected Device till April 2014 with Jumper the fields On Request Data Change On Timer and Time ms are not available ADFweb com S r l AL Industrial Electronic Devices DEFINE TRANSMIT 31939 User Manual J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 21 of 29 By pressing the Define 31939 button near Transmit J1939 from the main window of SW67215 Fig 2 the window Define Transmit J1939 appears Fig 7 The meaning of the fields of the table are In the field List of Receive J1939 Frames there is the list of frames J1939 who you inserted in Transmit J1939 Section In the field List of Modbus Registers there is the list of Modbus registers you have defined for the selected J1939 frame In the field Index of Modbus Register insert a value for the Modbus register In the field Selecet the Byte to put in the High Part of Modbus Register select which byte of the J1939 frame you want to save in the high part of Modbus register In the field Selecet the Byte to put in the Low Part of Modbus Register select which byte of the J1939 frame you want to save in the low part of Modbus register In the field Send J1939 frame on Modbus Write is possible to decide if the 31939 frame is sent when the related Modbus register is written by the Modbus master For
10. example Define Modbus Registers for Transmit 11939 Frames List of Transmit 11839 Frames List of Modbus Registers Create Modify a Modbus Register PRIOR DP FGN Relative to the PGN Selected Index of Modbus Register 201 203 Byte Fie Byte 8 Select the Byte to Put in the High Part of the Modbus Register Byte 3 Select the Byte to Put in the Low Part of the Modbus Register wy Delete E Copy Figure 7 Define Transmit J1939 window Select one of the J1939 frames you have defined insert a valid address in the field Index of Modbus Register select the byte position Byte 1 in high MODBUS byte and Byte 2 in low MODBUS byte press the Create button In the field List of Modbus Registers appears the modbus register you have defined ADFweb com S r l User Manual J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 22 of 29 AL Industrial Electronic Devices ENABLE REMOTE REQUEST RTR If the field Enable Remote Request RTR that is present in the section Set Communication is checked you need to define the Modbus registers that are used to compose the Remote Request In the Priority and Destination RTR register you have to indicate the Priority of the request in the high byte of the register usually this value is equal to 6 and the Address of the Destination Device in the low byte of register In the first left PGN RTR register you have to indicate t
11. insert the byte which you would start read this field is enable only when the field Transport Protocol is checked In the field Num Bytes insert the number of byte you would read for example your Start Byte is 20 an Num Bytes is 10 you can read the byte from 20 to 30 If the field On Request is checked the converter send the request frame to the related PGN in order to receive the frame with the data Inthe field Time ms is possible to insert the interval used to send the frame On Request If the field Cancel Data is checked and the Modbus Register in the section set communication is O the gateway when the data is oldest of the time inserted in the time out data you visualize FFFF in the Modbus registers of this PGN In the field Mnemonic the description for the frame is defined p Note TA If is selected Device till April 2014 with Jumper the fields On Request and Time ms are not available ADFweb com S r l User Manual J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 19 of 29 AL Industrial Electronic Devices DEFINE RECEIVE J1939 By pressing the Define 31939 button near Receive J1939 from the main window of SW67215 Fig 2 the window Define Receive J1939 appears Fig 5 SW6 7 2 1 5 Define Modbus Registers for Receive 11939 Frames The meaning of the fields of the table are
12. of 29 AL Industrial Electronic Devices DISCLAIMER All technical content within this document can be modified without notice The content of the document is a under continual renewal For losses due to fire earthquake third party access or other accidents or intentional or accidental abuse misuse or use under abnormal conditions repairs are charged to the user ADFweb com S r l will not be liable for accidental loss of use or inability to use this product such as loss of business income ADFweb com S r l shall not be liable for consequences of improper use OTHER REGULATIONS AND STANDARDS WEEE INFORMATION Disposal of old electrical and electronic equipment as in the European Union and other European countries with separate collection systems um his symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of human health which could otherwise be caused by inappropriate disposal The recycling of materials will help to conserve natural resources For more information about recycling this product please contact your local city office your household waste disposal service or the shop where you purchased the product RESTRICTION OF HAZARDOUS S
13. parameters Impedance 120 Ohm m Delay 5 ns m Length Baud Rate bps Length MAX m 10 K 5000 20K 2500 50 K 1000 100 K 650 125 K 500 250 K 250 500 K 100 800 K 50 1000 K 25 Here some codes of cable Belden p n 3105A 1x 22WG stranded twisted pairs conductor foil shield braid shield ADFweb com S r l User Manual J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 12 of 29 AL Industrial Electronic Devices MODBUS TCP The MODBUS TCP connection must be made using Connector3 HD67215 A1 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC PLC other is recommended the use of a cross cable Connector3 ro Ethernet Port oe RJ45 Plug ADFweb com S r l User Manual 31939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 13 of 29 AL Industrial Electronic Devices USE OF COMPOSITOR SW67215 To configure the Converter use the available software that runs with Windows called SW67215 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on our web site The software works with MSWindows XP Vista Seven
14. Converter Inthe fields SUBNET Mask insert the SubNet Mask In the fields GATEWAY insert the default gateway that you want to use This feature can be enabled or disabled pressing the Check Box field This feature is used for going out of the net In the field Port the port number used for Modbus communication is defined If is selected Device till April 2014 with Jumper there are three other fields and their meanings is If the field Enable write J1939 on request is checked the field Write J1939 frame in Transmit J1939 frame info is enabled If this field is not checked the device send a J1939 frame for every written register Otherwise it is possible to select when to send the J1939 frame If the field Enable Fun 1 2 5 and 15 is checked the Modbus function for the status are enabled It is possible to use the status bit to read or write the data of J1939 The definition of the register are fixed and start from 1 or 2 if the Master Modbus has the offset for the number of byte that you use per 8 If the field Write Modbus Registers also in read mode is checked is possible to read the registers that are been created into the section Define Transmit J1939 ADFweb com S r l J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 17 of 29 SW67215 Set Communication Setting Select Device Device till April 2014 with Jumper 11939 Baudrate 250K TimeOu
15. UBSTANCES DIRECTIVE 4 The device respects the 2002 95 EC Directive on the restriction of the use of certain hazardous substances in electrical OHS and electronic equipment commonly referred to as Restriction of Hazardous Substances Directive or ROHS 2002 95 EC CE MARKING C The product conforms with the essential requirements of the applicable EC directives ADFweb com S r l User Manual J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 29 of 29 AL Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT For fast and easy technical support for your ADFweb com SRL products consult our internet support at www adfweb com Otherwise contact us at the address support adfweb com RETURN POLICY If while using your product you have any problem and you wish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exchanged and returned within three weeks If the product is no longer under warranty you will receive a repair estimate ADFweb com S r l Via Strada Nuova 17 IT 31010 Mareno di Piave TREVISO Italy
16. User Manual J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 1 of 29 Industrial Electronic Devices User Manual Revision 2 000 English 31939 Modbus TCP slave Converter Order Code HD67215 A1 HD67215 B2 For Website information www adfweb com Product HD67215 For Price information www adfweb com Price HD67215 A1 For others Gateways Bridges www adfweb com Price HD67215 B2 J1939 to Modbus See also the following links Benefits and Main Features www adfweb com Product HD67212 Modbus RTU 4 amp Very easy to configure CANopen to Modbus See also the following links www adfweb com Product HD67001 Modbus RTU Master r3 Temperature range 40 C 85 C 40 F 185 F www adfweb com Product HD67002 Modbus RTU Slave www adfweb com Product HD67004 Modbus TCP Master www adfweb com Product HD67005 Modbus TCP Slave 4 Triple Electrical isolation For others Gateways Bridges For CAN bus 2 0A and or CAN bus 2 0B to Modbus See also the following links www adfweb com Product HD67011 Modbus RTU Slave www adfweb com Product HD67012 Modbus RTU Master www adfweb com Product HD67014 Modbus TCP Slave www adfweb com Product HD67015 Modbus TCP Master Do you have your customer protocol Then go to www adfweb com Product HD67003 Do you need to choose a device Do you want help www adfweb com Cmd helpme User Manual ADFweb com S r l Industrial Electronic Devices
17. as got two function modes depending on the position of the Dip2 of Dip Switch A The first with Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for uploading the Project and or Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specific functions see LEDS section Dip Switch A Dipi Must be at ON Dip2 Functioning mode H I H Normal H Boot i Dip Switch A Dipi Must be at ON Dip2 Functioning mode n Warning Dip1 of Dip Switch A must be at ON position to work even if the Ethernet cable is not inserted ADFweb com S r l User Manual J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 10 of 29 AL Industrial Electronic Devices LEDS The device has got four five LEDs that are used to give information about the functioning status The various meanings of the LEDs are described in the table below LED Normal Mode Boot Mode a l Blinks quickly Boot state 1 J1939 communication Blinks when arrive J1939 frames Blinks very slowly 0 5Hz update in progress ON Ethernet cable connected Blinks quickly Boot state OFF Ethernet cable disconnected Blinks very slowly 0 5Hz update in progress E l l Blinks quickly Boot sta
18. ator Example FREMM CR EDC7 REVO FREMM CR EDC7 REVI FREMM CR EDC7 REV1 FirstCorr FREMM CR EDC REV2 FREMM CR EDC REV4 McDonald ADFweb com S r l User Manual 391939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 15 of 29 AL Industrial Electronic Devices SOFTWARE OPTIONS By pressing the Settings gt button there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software SW 6 2 1 5 Software Options Language Connection Options Selected Language English English SW67215 Software Options Enable Internet Connection Check Software Update at Start of Program Check Available Update In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67215 check automatically if there are updatings when it is launched ADFweb com S r l AL User Manual Document code MN67215 ENG Industrial Electronic Devices SET COMMUNICATION This section define the fundamental communication parameters of two buses BACnet and Modbus TCP By Pressing the Set Communication button from the main window of SW67714 Fig 2 the window Set Communication appears
19. e is the necessity to insert an offset of 1 from what is defined in the Compositor and what you request i e if in the Compositor you have defined register 114 you have to require the 115 ADFweb com S r l AL User Manual 31939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 20 of 29 Industrial Electronic Devices TRANSMIT J1939 By pressing the Transmit J1939 button from the main window of SW67215 Fig 2 the window Transmit J1939 Frames appears Fig 6 The meaning of the fields of the table are In the field Priority insert the priority of the frame in J1939 protocol is a SW672 1 D number among 0 1 2 3 4 5 6 7 The Transmit 31939 Frames number O is the highest priority and 7 is the lowest In the field Data Page insert the data page in the J1939 protocol is O or 1 In the field PGN insert the PGN of the data you would to write from modbus to J1939 in the J1939 protocol the PGN is In the field Source Address you insert the ID of device that send the Figure 6 Transmit J1939 Frames window frame If the field On Request is checked the frame is sent when the converter receives the On Request command If the field Data Change is checked the frame is sent when the data changes If the field On Timer is cheched the frame is send cyclically In the field Time ms insert the interval used to send the frame with the option On
20. e values aren t updated when the FECA frame arrive but there is an offset of xx ms You can use this function if there is only one J1939 device in the network J1939 Modbus TCP slave Revision 2 000 Page 16 of 29 SW67215 Set Communication Setting Select Device Device from May 2014 with Dip Switch v 31939 Baudrate 250K TimeOut Data s 2 Modbus Reg TimeOut 99 Enable Peer to Peer Device ID J1939 Filter FECA ms Modbus TCP Slave IP ADDRESS 192 166 SUBNET Mask 250 200 GATEWAY 192 158 Port 302 Figure 3 Set Communication window ADFweb com S r l User Manual AL Industrial Electronic Devices If is selected Device till April 2014 with Jumper there are two more fields the meaning of them is If the field Enable Remote Request RTR is checked it is possible to use the Remote Request To use this is necessary to insert in the four fields under the four Modbus Registers used see ENABLE REMOTE REQUEST RTR section If Send Frame Every ms is checked the converter sends the J1939 frames defined in Transmit J1939 section every xx ms Otherwise a frame is sent in J1939 when a modbus register is written into the gateway The field Device ID J1939 is not present withthis type of device The meaning of the fields of Modbus TCP Slave is Inthe fields IP ADDRESS insert the IP address that you want to give to the
21. en all the operations are OK turn off the Device Put Dip2 of Dip Switch A in OFF position Turn on the device SW672 1 At this point the configuration firmware on the device is correctly updated Update Device from Ethernet UDP Update Device Options Firmware Read Firmware when finish Project Read Project when finish ut Execute update firmware INIT Waiting Ver 1 001 FIRMWARE Waiting PROJECT Waiting Figure 8 Update Device windows ADFweb com S r l iV User Manual J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 24 of 29 Industrial Electronic Devices If you know the actual IP address of the device you have to use this procedure Turn on the Device with the Ethernet cable inserted Insert the actual IP of the Converter Press the Ping button must appear Device Found Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK the device automatically goes at Normal Mode At this point the configuration firmware on the device is correctly update J Note A When you install a new version of the software if it is the first time it is better you do the update of the Firmware in the HD67215 A1 or HD67215 B2 device J Note TA When you receive the device for the first time you also have to update the Firmware in the HD67215
22. f the converter Select the COM port and press the Connect button Turn on the device Check the Device state Led It must blink quickly see LEDS section Press the Next button Select which operations you want to do Press the Execute Update Firmware button to start the upload When all the operations are OK turn off the device Remove the Jumper Disconnect the RS232 cable Turn on the device At this point the configuration firmware on the device is correctly updated D Ver 2 001 IMIT Waiting FIRMWARE Waiting PROJECT Waiting Figure 10 Update Device by Serial windows p ADFweb com S r l SW67215 Update Device Using the Serial Port Follow these steps to update from RS232 1 Turn OFF the Device 2 Use the Dip Switch to set the Boot Mode 3 Select the COM Port for the Update 4 Turn ON the Device SW67215 Update Device Using the Serial Port Update Device Options Firmware Read Firmware After Write Configuration Read Configuration After Write a Execute Update Firmware User Manual J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 26 of 29 AL Industrial Electronic Devices MECHANICAL DIMENSIONS am ee o O LED4 Device state Lo Grd Hi V OV e C LED3 Modbus communication 31939 port Power Supply Dip Switch C 8 24V AC dig 31939 Modbus TCP slave Converter 100 28 HD67215
23. he first two byte of the PGN while in the second right PGN RTR register you have to indicate in the high byte of register the third byte of the PGN In the Source Address RTR register you have to indicate the Source Address of the request in the high part of the register Only when you write the Souce Address register the request will be send to the J1939 network For example if you want to request the PGN OxOOFEES5 at device with address 5 you have to write 1st reg 0x0605 2nd reg OxE5FE 3rd reg 0x0000 4th reg 0x0100 ADFweb com S r l User Manual 31939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 23 of 29 AL Industrial Electronic Devices UPDATE DEVICE By pressing the Update Device button it is possible to load the created Configuration into the device and also the Firmware if necessary If you don t know the actual IP address of the device you have to use this procedure Turn off the Device Put Dip2 of Dip Switch A in ON position SW672 1 5 Update Device from Ethernet UDP Turn on the device Connect the Ethernet cable Insert the IP Address of HD67434 Insert the IP 192 168 2 205 iss 2 205 Press the Ping button Device Found must appear Check the Connechon the device Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload Wh
24. information between Modbus TCP bus and J1939 bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F 4 4 4 CONFIGURATION You need Compositor SW67215 software on your PC in order to perform the following Define the parameters of J1939 line Define the parameters of Modbus TCP line Define the J1939 frames that contains the data that are readable by a Modbus TCP master Define the J1939 frames that are sent with the data that arrives from a Modbus TCP master Update the device ADFweb com S r l AL User Manual J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 8 of 29 Industrial Electronic Devices POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below Consumption at 24V DC Bevce Consumption W VA HD67215 B2 3 5 V M Positive Wins B ona l l V AC min 8V max 24V cepe V DC min 12V max 35V aiii Caution Do not reverse the polarity power AA HD67215 A1 HD67215 B2 Connector1 Power Supply port OV Ground tV Positive wire V AC min 8V max 24V V DC min 12V max 35V ADFweb com S r l User Manual J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 9 of 29 AL Industrial Electronic Devices FUNCTION MODES The device h
25. rd if they are inappropriately installed and operated by untrained personnel These instructions refer to residual risks with the following symbol This symbol indicates that non observance of the safety instructions is a danger for people that could lead to serious injury or A death and or the possibility of damage CE CONFORMITY The declaration is made by our company You can send an email to support adfweb com or give us a call if you need it ADFweb com S r l iV User Manual 31939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 4 of 29 Industrial Electronic Devices EXAMPLE OF CONNECTION Modbus TCP network J1939 network bea LI SIE ECCE NE EA f pee 22b P m J1939 devices Modbus TCP Client HD67215 A1 ADFweb com S r l User Manual J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 5 of 29 AL Industrial Electronic Devices CONNECTION SCHEME Dip Switch A Dipi Must be at ON Dip2 Functioning mode E am a C LEDA Device state E Lo Grd Hi V OV O LEDA Modbus communication E J1939 port Power Supply Dip Switch C B 24 AC ar it 35W DC J1939 Modbus TCP slave Converter 100 HD67215 A1 ELED Ethernet Link i Esca www ADFweb com E Ethernet Q n o C Dip Switch A Bail DTI LEDI 31939 z cs B185 MAC 10 64 E2 07 38 3C Rail DIN a communicaticn d Date Code 31 14 Serial Nr C3468 WoHS Clamp
26. t Data 5 2 Modbus Reg TimeOut 99 Enable Peer to Peer Enable Remote Request RTR Priority and Destination RTR O PGN RTR o o Source Address RTR D Filter FECA ms 50 Send Frame Every ms Modbus TCP Slave IP ADDRESS 192 168 SUBNET Mask C GATEWAY 192 168 Port 502 Enable write 11939 on request Enable Modbus Fun 1 2 5 and 15 C Write Modbus Registers also in read mode User Manual J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 18 of 29 AL Industrial Electronic Devices RECEIVE J1939 By pressing the Receive 31939 button from the main window of SW67215 Fig 2 the window Receive J1939 Frames appears Fig 4 The meaning of the fields of the table are In the field Data Page SW67215 Receive J1939 Frames insert the data page the value is O or 1 usually is ne pataPage pcu Source Address Transport Protocol 0 1 o OxFECA 0x01 25 1000 l In the field PGN insert OxFEEE 0x01 O s the PGN of the data you OxFEBA 0x01 would to read from modbus Ox028A 0x01 to J1939 in the J1939 protocol the PGN is an identifier In the field Source Address insert the Figure 4 Receive J1939 Frames window address of the device that send the frame If the field Transport Protocol is checked the frame use Transport Protocol functions In the field Start Byte
27. te 3 Modbus communication Blinks when arrive Modbus TCP requests Blinks very slowly 0 5Hz update in progress Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Ethernet Link 4 Device state Blinks slowly 1Hz 5 Not used present only on Blinks quickly Boot state Not used HD67215 B2 Blinks very slowly 0 5Hz update in progress Led4 Yellow Device state communication 60 G Power Supply MAC LOE O amp Ov aV Serial Miri C2559 12 35V DE Fe oan d NE Y a a Sh if E z wwe ADP webcam HD67215 B2 31939 Modbus TCP slave Converter 100 on 1939 port communication Dip Switch A pip mwiteh c Lo Gnd Hi Led5 Yellow OOOoOO0o0o000009Q Not used ADFweb com S r l User Manual J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 11 of 29 AL Industrial Electronic Devices 31939 To terminate the J1939 line with a 120 resistor it is necessary that the Dip1 of Dip Switch C is at ON position Dip Switch C Dipl J1939 Termination Resistor Dip2 Not used _ Connector2 Dip Switch C 31939 port Isolated port Dipi J1939 Termination Resistor Dip2 Not used Hi High wire Shl Shield to Isolated Ground Lo Low wire J1939 port Isolated port i Hi High wire HT Shl Shield to Isolated Ground Hi Shl Lo Lo Low wire Cable characteristics DC parameter Impedance 70 Ohm m AC
28. tion 17 01 2011 Dp AI Software changed 1 014 12 02 2013 Added new chapters 1 015 14 03 2013 Dp All Software changed 2 000 29 07 2014 WARNING ADFweb com reserves the right to change information in this manual about our product without warning ADFweb com is not responsible for any error this manual may contain TRADEMARKS All trademarks mentioned in this document belong to their respective owners AL User Manual J1939 Modbus TCP slave Document code MN67215 ENG Revision 2 000 Page 3 of 29 Industrial Electronic Devices SECURITY ALERT GENERAL INFORMATION To ensure safe operation the device must be operated according to the instructions in the manual When using the device legal and Safety regulation are required for each individual application The same applies also when using accessories INTENDED USE Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator i e independent limit switches mechanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a potential haza