1. MULTIFUNCTIONAL ELECTRONIC TARGET II USER S MANUAL 8 External Switch 9 Wall Mount 1 Power Mode Button 2 Volume 7 Reserved 6 Signal Port 2 5 Screw Base 4 Dip Switch The number of USB power supplies depends upon the length of wire used in the configuration and the number of targets There are two scenarios D The number of targets is less than 10 1 USB power supply is required for every 15 meters of wire e g for 9 targets each target will use 5 meters of wire In this case you will need 45 meters of wire As one USB power supply is required at every 15 meters you will need 3 USB power supplies Please see figure 1 for more details Less than 10 targets Length 45 meters USB power supplies 3 15m 15m 15m 15m 30m 45m METI o Fig 1 AC USB power adapter USB port of power bank Do not connect the USB port to a computer ATTENTION 3 Signal Port 1 The G amp G second generation MET has increased sensitivity 4 LEDs volume speakers and can be mounted on a wall An independent power source is not required when linked up to multiple units linked units will only require one power source The second generation has 7 game settings previously 4 waiting to be challenged Control Panel 1 Power Mode Power On Off Mode switch Start button 2 Volume Control Up and down 3 Signal Port For connecting other units 4 DIP Switch DIP 1 amp 2 for
2. viode Sensor Abnormality Troubleshooting Guide Status Condition of the MET 1 MET flashes red and blue Tapping the unit is ineffective and the red and blue flashing is frequent 2 MET displays the normal state but sensors are inactive or have decreased sensitivity 3 When turned on and the MET displays red even without firing at it If the above conditions are displayed it indicates that there is sensor abnormality in the MET Please refer to the troubleshooting method below Check the 2nd generation MET Cover the green part of the MET for damages If there are damages and the sensors are unresponsive please replace the MET Cover Remove the skirt cover Remove the MET Cover Remove the small black cap by pulling in the opposite direction from the copper plate and wires as depicted You can then check if the electrostaticity is too strong This is caused by incorrect positioning of the small Styrofoam ball Eu E Y PEN N Otago miele f Time be Remove the small styrofoam ball and store it in a safe place Spray a small amount of Anti Static spray inside the compartment from where the Styrofoam ball was housed Caution Do not over spray Anti Static spray inside the housing or the spray will not dry out fast enough and cause the Styrofoam ball to stick on the housing It is recommended to spray the Anti Static spray with 30cm distance amp Spray a small amount of Anti Stati
3. ady for mode selection 2 Mode selection After powering on quickly press the start button to select the desired modes Mode selection is available 3 seconds after power up For example quickly pressing twice will take you to Mode 2 the red light will flash twice 3 Different power up selections Functionality A Power Source Input DC 5V Operating current 75 600mAMAX Power Bank Output above 2 0A Model G 11 065 gt optional USB Adapter Output above 2 0A Model G 11 068 US type G 11 069 EU type gt optional It is recommended to add more power sources when using additional MET units If the distances between targets is increased some instability may occur adding more power sources is recommended B Visual amp Sound Effects During stand by Ready mode Blue light displayed Once hit Red light displayed When flashing red The battery power is low Mode 4 and mode 6 has different colors DIP switch 3 Blue Red options Reset power on unit again to activate 4 different sounds internal speakers DIP switches 1 amp 2 selects the sound effects no need to reset C 0 3 2J Sensitivity Product sensitivity between 0 3J 2J 10 Meter distance D 360 Covering Angle When MET becomes unstable due to interference from other sources the MET system will shut down automatically to keep the fairness of the game 1 Standard Mode Hold the start button for 2 seconds
4. c Spray on the inside bottom of the small bla When the Anti Static Spray is dry reinstall the small styrofoam ball into the compartment and reinstall the small black cap Make sure the small black cap clicks closed If the cap does not properly cover the compartment then electrostaticity will deform the copper plate causing malfuncitions Repeat Steps 1 8 on the auxiliary MET Targets Reinstall MET Cover and Skirt Align the arrow on the Skirt with the mounting holes
5. re 1 4 20UNC I Operating temperature 5 40 C Trouble Shooting A When the auxiliary targets malfunction after powering on remove the primary target and connect it to a stand alone target Do the same for the other targets B Sensor malfunction may be caused by a misaligned sensor ball the target will flash red and blue or display a constant red light after powering on This can be fixed by tapping the target 2 to 3 times This causes a change in air pressure which may help the sensor ball recalibrate User s Manual G amp G 1986 ARMAMENT WWW GUAY2 COM G1 201312 04 G amp G ARMAMENT AIRSOFT GUNS amp ACCESSORIES User s Man A nn E mode all targets are in stand by mode with on When the first target is hit it will turn targets light will be shut off This mod determine who hit the target first Press the start button again to al reinitiate competition mode a Connection Other than having different lengths there are 2 types of lines cables LELLI ms ee 1 Data cable Connects 2 MET units tT ES 2 Signal line USB electrical line Coupled with a signal line the USB electrical line can support both signals and electricity When the signal line is over 30 meters an extra power source needs to be added If the first MET unit has a 15 meter line and the second MET unit also has a 15 meter line the second MET unit will need to use
6. sound effects DIP3 for colors choices blue red Resetting is not required for changing sound effects however switching color choices requires resetting 5 Screw Base 1 4 20UNC inclusive screw 6 Signal port 2 Used to connect one target to another same functionality as Port 1 7 Reserved No usage 8 External Switch same functionality as Power Mode Model G 11 071 Standard G 11 070 Metal gt optional 9 jWall Mount 3 16 x L25mm wall mount dimensions recommend flat screw philip s HH He He He He He He HK HK He He KH He He eK Re Ke He Re ee ee ee ee mp er er ee ee er er ee er ee er er ee ee ee ee er ae ee ee ae ee ee ee ee ee ae ee ee ae ee ee ee ee ae ee ae ae ae ae ae ae a ee a ea a a a ae nr a ea aaa aaa ee a aa a aaa a aa a aa a a aa a aa a ea aaa a ea ea ae He eK KH Ke KH He Ke He Ke Ke Ke He Ke Ke He eH KH Ke KK 2 The number of targets is more than 10 e g for 11 targets each will use 1 meter of wire You will therefore need 11 meters of wire In fact one additional USB power supply will be required for the eleventh target Please see figure 2 for more details More than 10 targets Length 30 meters USB power supplies 3 10 m 10 m 10m 20m 30m 10m N AC USB power adaptor USB port of power bank 1 Hold button for 2 seconds to turn on off 2 sound effects indicate the unit has been powered on The second sound means you have entered Shooting Mode and are re
7. the USB line as a power source Power Distributions To link 25 units for example use 6 sets of wires signal wire ground wire for the first 7 units Between the 7th and 8th add the USB power wire signal wire USB power wire ground wire and connect the ground wire from the 1st unit to the 8th unit s ground wire only required when signal is unstable AGhallenge Modes vadifferent game modes First turn onithe tangettasiMastermlianget Abnormal Status 1 A misaligned sensor ball will cause the MET to flash red and blue or constantly display red after powered on 2 Ared light flashes when low on power How to link up targets a 2 gt 2 2 gt 2 ex 5 targets 1 Link up targets in lines do not link in a closed loop 2 It is recommended to place the initial target first in line Attention 1 Check batteries wires etc before use 2 The longer the distance the weaker the signals Please take precautions and follow the manufacturer suggested guidelines 3 If the target displays an abnormal status has a loose connection wire and or is low in power etc troubleshoot the problem before use to avoid causing a chain reaction on other targets 4 When not in use please turn off the power and remove power sources to save energy and for safety 5 Warning please use original accessories to avoid unnecessary occurances P B h AS oll Fo u RJ Fh P Fh 2 Rar ad om
8. to turn on off All connected units will flash with the Master unit 2 Challenge Mode turn off on the unit by following the steps in Standard Mode To select a Challenge Game Mode press the start button multiple times number of presses dependant on the mode and hold the button on the last press for more than one second For example to select the Random Game Mode press 4 times and hold the 4th press for 1 second to activate the mode After activation the Master unit will flash 4 times number of flashes dependant on the mode selected with a sound effect other linked units will not flash and then turn off After entering a challenge mode you will only need to press the button once to activate the Random game mode After you have finished the game all units will return to the initial challenge mode except a game in the Time Bomb mode In Challenge Mode you will not be able to select the Competition or Quick Draw games E 1 25 Targets max Multi Targets 25 being Maximum When the distance between units is greater than 15 meters it is recommended to add a power source for every 3 units Normal usages 0 5 meters apart 8 units can share one power source Please refer to the Wiring section for more information F Silicon domes target cover durable for at least 50 000 hits G Wall mounting specifications 3 16 x L25mm recommend flat screw philip s head H Screw dimensions for inbox a