Contents
1. other equipment Environment All System Components Transport Storage Operating 20 C 49 C 95 R H Max 500hPa 1060hPa Altitude 10 C 40 C 95 R H Max 500hPa 1060hPa Altitude The CE mark on this product indicates it has been tested to and conforms with the provisions noted in the 93 42 EEC C Medical Device Directive Authorized European Representative European Regulatory Manager Welch Allyn Ltd Navan Business Park Dublin Road Navan County Meath Republic of Ireland Telephone 353 46 67700 Fax 353 46 27128 SERVICE AND WARRANTY Service Information Other than battery replacement this equipment contains no user servicable parts Return to a Welch Allyn authorized service center for service For Technical Support or to obtain return instructions please contact your nearest Welch Allyn service center listed below Welch Allyn Inc 4341 State Street Road skaneateles Falls NY 13153 0220 Telephone 800 535 6663 Fax 315 685 4653 Welch Allyn Ltd UK Cublington Road Aston Abbotts Buckinghamshire England HP22 4ND Telephone 011 0207 365 6780 Fax 011 0207 365 9694 Welch Allyn LTD Singapore 300 Beach Road The Concourse 25 08 singapore 199555 Telephone 011 656 291 08872 Fax 011 656 291 5780 Welch Allyn Ltd Australia The Metro Centre Unit 5 38 46 South Street Rydalmere NSW 2116 Australia Telephone 011 612 9638 3000 Fax 011 612 9638 3500 Welch Allyn
2. Ltd Canada 160 Matheson Blvd E Unit 2 Mississauga Canada L4Z 1V4 Telephone 905 890 0004 Fax 905 890 0008 Welch Allyn GmbH PSC Zollerstrasse 2 4 D72417 Juningen Germany Telephone 011 49 7477 927186 Fax 011 49 7477 927293 Welch Allyn China Service Center Room 708 Central Plaza No 277 Huang Pi Bei Rd Huang Pu District shanghai 20003 China Telephone 011 86 21 63279631 FAX 011 86 21 63279632 Warranty The 719 series Power Handle is guaranteed by Welch Allyn against all manufacturing defects Welch Allyn will repair or replace free of charge any parts of its own manufacture proven to be defective through causes other than misuse neglect damage in shipment Or normal wear Welch Allyn warrants that the Welch Allyn 71960 Battery Section will perform to original specifications during the two years from the date of manufacture when used with the Welch Allyn 719 series Power Handle This warranty does not apply to the use of the 71960 battery in other products A defective battery will be replaced if it fails within two years of the date of manufacture 719209 3 FAX
3. S aaa Light Intensity Rheostat Section Chrome Ring 1 Connect instrument head to the handle Control Ring a 2 Depress On Off Button on Rheostat Section On Off spiel ection and rotate the Light Intensity Control Ring Button clockwise CW To intensify light continue to rotate until stop is reached Figure 1 3 To turn off rotate counter clockwise CCW Figure 1 Button will click when fully off Turn fully off after each use to ensure maximum on time from the battery CHARGING INSTRUCTIONS 7114x Universal Charger 1 Insert the handle into the Well Charge for 24 continuous hours to charge a dead battery less to top off Low Battery Indicator 2 Fully charged handles may remain in the Charger if desired 3 Charging the Battery after partial discharge does not negatively affect overall battery memory unlike Ni Cad cells 71110 Desk Charger obsolete and Ophthalmic Stands see well adapter instructions for installing well adapter s Once adapters are installed follow charging procedures indicated under the 7114x Universal Charger NOTE The Battery Section is not shipped fully charged For maximum performance charge the Battery Section for 24 hours when new or after a long period of inactivity LOW BATTERY INDICATOR 1 The Low Battery Indicator will illuminate several minutes before handle shuts off depending on the age of the battery Figure 1 2 Once the battery is fully discharged the Low Battery Indic
4. WelchAllyn 719 Series Lithium lon Handle INTRODUCTION Thank you for purchasing the Welch Allyn 719 Series Lithium lon Power Handle The handle is intended for use as a power source for all Welch Allyn standard instrument heads The 719 series represents a new generation of handles from Welch Allyn Taking advantage of new battery technology the 719 series provides you double the on time in a smaller and lighter weight package smarter battery technology means that memory is no longer an issue What s more the 719 reminds you to recharge with its low battery indicator The soft rheostat section provides a sure grip and the overall design is ergonomically sound This handle is chargeable in the Welch Allyn Universal Charger It is also chargeable in the Welch Allyn 7111x obsolete Desk Charger and most standard 120V ophthalmic stands with the use of a Welch Allyn Well Adapter see 71980 90 Well Adapter User Manual for manufacturer model chart Before using this product please read the following warnings and instructions SAFETY AND WARNINGS Attention Read Operating Manual for Cautions and instructions for use e POSSIBLE EXPLOSION HAZARD Equipment not suitable for use in the presence of a flammable anesthetic e Use the 719 Series Handle only with Welch Allyn approved products and chargers eWelch Allyn p n 71960 Battery Section is only suitable for use with the 719 series handle e Do not disassemble or modify the battery pa
5. ator may flicker INSTALLING 71980 WELL ADAPTERS INTO THE 71110 DESK CHARGER 1 Insert the Well Adapter into one of the Handle Receptacles in the Desk Charger Be sure to insert the Adapter until it is fully seated Once the Well Adapter has been installed it does not need to be removed Figure 2 2 One or two Well Adapters may be used with the Desk Charger BATTERY REPLACEMENT Removing the old Battery Section 1 Hold the instrument handle firmly by the Battery Section 2 Turn the Rheostat Section Counterclockwise until it detaches from the Battery Section see figure 2 Installing A New Battery Section CCW 1 Insert the Rheostat Section into the new Battery Section Figure 2 2 To connect the two sections turn the Rheostat Section clockwise until tight see figure 2 3 Verify the Rheostat Section is secure on the Battery Section of the instrument handle CLEANING The cleaning of all Welch Allyn power handles and chargers is easily accomplished by wiping the external surface with a cloth dampened with a mild detergent and water solution 70 isopropyl alcohol or a 10 bleach solution by volume Do not immerse NOTE Excess solution entering the assembly could damage internal components Use caution to ensure cloth is not saturated with solution Do not sterilize the 719 Series Power Handle or Well Adapter Battery Recycling Welch Allyn now employs the services of an agency which can disassemble and recycle all compo
6. ck There are no serviceable parts inside e Do not attempt to directly solder to the battery pack e Do not attempt to connect the positive and negative terminals to each other nor to any other device e Do not charge battery pack in any environment where the temperature may exceed 40 C 104 F or fall below 0 C 32 F e Do not dispose of the battery section in fire or water Do not puncture incinerate or subject to strong impact or shock e Do not immerse the battery pack in any liquid e Do not strike or throw the battery pack e Do not use a battery pack which appears deformed leaking corroded or is otherwise irregular e Handle a damaged or leaking battery with extreme care If you come into contact with the electrolyte wash the exposed area with soap and water If it contacts the eye flush the eye with water for 15 minutes Seek medical attention immediately eWhen discarding a battery pack contact your local waste disposal service provider regarding local restrictions on the disposal or recycling of batteries e o avoid the risk of fire burns or damage to your battery pack or lamp do not allow a metal object to touch across the battery contacts FOR BEST PERFORMANCE e Do not expose battery pack to storage temperatures above 50 C 122 F or below 20 C 4 F e Do not discharge battery pack if the ambient temperature is above 60 C 140 F or below 20 C 4 F Parts List Instrument Head OPERATING INSTRUCTION
7. nents of rechargeable batteries so that nothing gets landfilled or incinerated Should you wish to dispose of your expended Welch Allyn rechargeable battery via recycling in the U S and Canada only please send to Welch Allyn Welch Allyn Canada RECYCLE BATTERY RECYCLE BATTERY 4341 State Street Road 160 Matheson Blvd East skaneateles Falls NY Mississauga Ontario 13153 0220 CANADA L4Z 1V4 For locations outside the U S and Canada consult your local recycling authority for correct disposal of batteries SPECIFICATIONS Specifications and design may change without notice Handle Model Number 71911 Dimensions 5 4 Long x 1 125 Diameter Max 137mm x 28 6 mm Weight 4 5 oz 128 g Typical Charge Time 24 hours fully discharged Typical Discharge Time 110 minutes for new battery Approvals Complies with IEC 60601 1 CAN CSA 22 2 No 125 and UL544 CY When used with 71980 Well Adapter and 711 series Desk Charger Equipment Classification TYPE BF Equipment Equipment Classification All Charger Model Numbers E Double Insulation Equipment Classification All System Components IXPO Equipment not protected against the ingress of water Operating Mode Continuous Operation NOTE This product complies with current required standards for electromagnetic interference and should not present problems to other equipment or is affected by other devices As a precaution avoid using this device in close proximity to