Home

Installing the Driver Kit

image

Contents

1. INITRD MODULES mptscsih jbd ext3 lpfc e For a system with Red Hat Enterprise Linux 4 with or without updates add the following line to the etc modprobe conf file if it does not already exist alias scsi hostadapter lt n gt lpfc where lt n gt is a number that is not used in any other scsi_hostadapter lines in the file Driver for Linux Installation Section Page 10 7 Execute the Ipfc install script with the createramdisk option tmp lpfc install createramdisk 8 If prompted reboot the system Uninstalling a Previous Application Helper Module Stand Alone Kit Note You must run the uninstall script that shipped with the version of the Application Helper Module you want to remove If the uninstall script resides in the usr src directory be sure to copy it to a temporary directory before you run it To completely remove the Emulex Application Helper Module Log on as root 2 If possible exit all applications that use Fibre Channel attached drives then unmount the drives If you cannot exit all applications that use Fibre Channel attached drives the uninstall will work properly but you must reboot after the uninstallation is complete 3 Stop HBAnyware Type cd usr src hbanyware stop hbanyware The script is located in the usr sbin hbanyware directory 4 Copy the ioctl install script to the temporary directory For example cp usr src lpfcdfc ioctl install tmp 5 Execute the ioctl inst
2. elx_mes0128 Xmit ELS ACC response tag lt ulploTag gt DESCRIPTION An ELS accept response for the specified IO tag has been sent DATA 1 ulpContext 2 nlp DID 3 nlp_flag 4 nlp_state 5 nlp_rpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0129 Xmit ELS RJT lt rejectError gt response tag lt ulploTag gt DESCRIPTION An ELS reject response with the specified error for the specified IO tag has been sent DATA 1 ulpContext 2 nlp DID 3 nlp_flag 4 nlp_state 5 nip_rpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0130 Xmit ADISC ACC response tag lt ulploTag gt DESCRIPTION An ADISC ACC response for the specified IO tag has been sent DATA 1 ulpContext 2 nlp_DID 3 nlp_flag 4 nlp_state 5 nip_rpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0131 Xmit PRLI ACC response tag lt ulploTag gt DESCRIPTION A PRLI ACC response for the specified IO tag has been sent DATA 1 ulpContext 2 nlp DID 3 nlp_flag 4 nlp_state 5 nip_rpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Driver for Linux Troubleshooting Section Page 26 elx mes0132 Xmit RNID ACC response tag lt ulploTag gt DESCRIPTION A RNID ACC response for the specified IO tag has been sent DATA 1 ulpContext SEVERITY Information LOG LOG_ELS
3. nlp rpi SEVERITY Information LOG LOG DISCOVERY LOG FCP verbose ACTION No action needed informational elx mes0217 Unknown Identifier in RSCN payload DESCRIPTION Typically the identifier in the RSCN payload specifies a domain area or a specific NportlD If neither of these are specified a warning will be recorded DATA 1 un word SEVERITY Error LOG Always ACTION Potential problem with Fabric Check with Fabric vendor elx_mes0218 FDMI Request DESCRIPTION The driver is sending an FDMI request to the fabric DATA 1 fe flag 2 hba_state 3 cmdcode SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0220 FDMI rsp failed DESCRIPTION An error response was received to FDMI request DATA 1 SWAP_DATA16 fdmi_cmd SEVERITY Information LOG LOG_DISCOVERY verbose ACTION The fabric does not support FDMI check fabric configuration elx_mes0221 FAN timeout DESCRIPTION A link up event was received without the login bit set so the driver waits E_D_TOV for the Fabric to send a FAN If no FAN if received a FLOGI will be sent after the timeout DATA None SEVERITY Warning LOG LOG_DISCOVERY verbose ACTION None required The driver recovers from this condition by issuing a FLOGI to the fabric elx_mes0222 Initial FLOGI timeout DESCRIPTION The driver sent the initial FLOGI to fabric and never got a response back DATA None SEVERITY Error LOG
4. 08 49 Irwxrwxrwx 1 root root 9 Mar 3 21 11 32000000c5005d6e4 gt sdb Irwxrwxrwx 1 root root 9 Mar 3 21 11 32000000c5005df9d gt sdc Irwxrwxrwx 1 root root 9 Mar 3 21 11 32000000c5005dfae gt sdd Irwxrwxrwx 1 root root 10 Mar 3 21 33 32000000c5005dfaet gt sdd1 Irwxrwxrwx 1 root root 10 Mar 3 21 33 32000000c5005dfae2 gt sdd2 In this example only the third disk sdd has partitions As partitions are added and removed udev creates and deletes the corresponding soft links RHEL 4 udev can be configured to create persistent names on RHEL 4 To do this first create a file called 20 local rules in the etc udev rules d directory containing just the following line KERNEL sd BUS scsi PROGRAM sbin scsi id SYMLINK disk c n The exact name of the file is not important but it must start with a number lower than 50 to override the default rules file Enable scsi id For RHEL only SLES does not require this step The scsi id utility generates unique identifiers for SCSI devices udev uses these identifiers to create a persistent name for devices under dev By default scsi_id is disabled Method 1 enable scsi_id for all devices Driver for Linux Configuration Section Page 19 You can enable scsi id by making the following changes to etc scsi id conf Change options b To HH options b And change options g To options g Method 2 enable scsi_id for particular
5. 1 hba_state 2 sli_flag 3 flag SEVERITY Information LOG LOG MBOX verbose LOG SLI verbose ACTION No action needed informational Driver for Linux Troubleshooting Section Page 37 elx mes0310 Mailbox command lt mbxcommand gt timeout DESCRIPTION A mailbox command was posted to the adapter and did not complete within 30 seconds DATA 1 hba state 2 sli flag 3 mbox active SEVERITY Error LOG Always ACTION This error could indicate a software driver or firmware problem If no I O is going through the adapter reboot the system If the problem persists report the error to Technical Support elx mes0311 Mailbox command lt mbxcommand gt cannot issue DESCRIPTION The driver is in the wrong state to issue the specified command DATA 1 hba state 2 sli flag 3 flag SEVERITY Information LOG LOG MBOX verbose LOG SLI verbose ACTION No action needed informational elx_mes0312 Ring lt ringno gt handler portRspPut lt portRspPut gt is bigger then rsp ring lt portR spMax gt DESCRIPTION The port rsp ring put index is larger than the size of the rsp ring DATA None SEVERITY Error LOG Always ACTION This error could indicate a software driver firmware or hardware problem Report these errors to Technical Support elx mes0313 Ring lt ringno gt handler unexpected Rctl lt Rctl gt Type lt Type gt received DESCRIPTION The Rctl Type of a received frame did not match any for the configured
6. 2 4096 SEVERITY Information LOG LOG_LIBDFC verbose ACTION Modify the user application issuing a CT request to allow for a larger response buffer Link Events 1300 1399 elx_mes1300 Re establishing Link timer expired DESCRIPTION The driver detected a condition where it had to re initialize the link DATA 1 fc flag 2 hba_state SEVERITY Error LOG Always ACTION If numerous link events are occurring check the physical connections to the Fibre Channel network Driver for Linux Troubleshooting Section Page 50 elx mes1301 Re establishing Link DESCRIPTION The driver detected a condition in which it had to re initialize the link DATA 1 status 2 status1 3 status2 SEVERITY Information LOG LOG LINK EVENT verbose ACTION If numerous link events are occurring check the physical connections to the Fibre Channel network elx_mes1302 Invalid speed for this board Reset link speed to auto lt cfg_link_speed gt DESCRIPTION The driver is reinitializing the link speed to auto detect DATA None SEVERITY Warning LOG LOG_LINK_EVENT verbose ACTION None required elx_mes1303 Link Up Event lt eventTag gt received DESCRIPTION A link up event was received It is also possible for multiple link events to be received together DATA 1 fc eventTag 2 granted AL PA 3 UlnkSpeed 4 alpa map 0 Detail If link events received log 1 last event number received 2 ALPA granted 3 Link speed
7. 3 lpfc_arg2 4 lpfc_outsz SEVERITY Information LOG LOG LIBDFC verbose ACTION None required elx mes1601 libdfc debug exit DESCRIPTION The exit point for processing diagnostic ioctl DATA 1 rc 2 Ipfc outsz 3 lpfc_dataout SEVERITY Information LOG LOG_LIBDFC verbose ACTION None required elx_mes1602 libdfc hbaapi entry DESCRIPTION The entry point for processing HBAAPI ioctl DATA 1 Ipfc cmd 2 lpfc_arg1 3 lpfc_arg2 4 lpfc_outsz SEVERITY Information LOG LOG_LIBDFC verbose ACTION None required elx_mes1603 libdfc hbaapi exit DESCRIPTION The exit point for processing HBAAPI ioctl DATA 1 rc 2 Ipfc outsz 3 lpfc_dataout SEVERITY Information LOG LOG LIBDFC verbose ACTION None required elx mes1604 libdfc error DESCRIPTION An error occurred in the Ipfcdfc ioctl module DATA 1 error number index SEVERITY Error LOG Always ACTION Reduce the application program s SCSI send request buffer size to less then 320K bytes elx mes1606 libdfc error DESCRIPTION An error occurred in the Ipfcdfc ioctl module DATA 1 error number index SEVERITY Error LOG Always ACTION Reduce the application program s SCSI send request buffer size to less than 320K bytes Driver for Linux Troubleshooting Section Page 52 elx mes1607 libdfc util exit DESCRIPTION The exit point for processing util ioctl DATA 1 rc 2 Ipfc outsz 3 lpfc_dataout SEVERITY Information LOG
8. DATA 1 nlp_flag 2 fc flag 3 fe_rscn_id_cnt SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0239 Skip lt Did gt NameServer Rsp DESCRIPTION The driver received a NameServer response DATA 1 size 2 fe flag 3 fe_rscn_id_cnt SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0240 NameServer Rsp Error DESCRIPTION The driver received a NameServer response containing a status error DATA 1 CommandResponse bits CmdRsp 2 ReasonCode 3 Explanation 4 fc flag SEVERITY Information LOG LOG_DISCOVERY verbose ACTION Check the fabric configuration The driver recovers from this and continues with device discovery elx_mes0241 NameServer rsp error DESCRIPTION The driver received a NameServer response containing a status error DATA 1 CommandResponse bits CmdRsp 2 ReasonCode 3 Explanation 4 fc flag SEVERITY Information LOG LOG_DISCOVERY verbose ACTION Check the fabric configuration The driver recovers from this and continues with device discovery Driver for Linux Troubleshooting Section Page 33 elx mes0244 Issue FDMI request failed DESCRIPTION Cannot issue an FDMI request to the HBA DATA 1 cmdcode SEVERITY Information LOG LOG Discovery verbose ACTION No action needed informational elx mes0245 ALPA based bind method used on an HBA which is in a nonloop topology DESCRIPTION
9. DID gt DESCRIPTION A remote NPort that was discovered by the driver disappeared for more than ELX NODEV TMO seconds DATA 1 nlp flag 2 nlp state 3 nlp rpi SEVERITY Error LOG Always ACTION If the device generating this message is not a target to which the HBA is connected this error will not affect the data integrity of the I O between the HBA and the attached storage and can be ignored elx_mes0204 Create SCSI Target lt tgt gt DESCRIPTION A mapped FCP target was discovered and the driver has allocated resources for it DATA None SEVERITY Information LOG LOG_DISCOVERY LOG_FCP verbose ACTION No action needed informational elx_mes0205 Abort Outstanding I O on Nport lt nlp_DID gt DESCRIPTION An outstanding I O on a remote Nport was aborted DATA 1 nlp_flag 2 nlp_state 3 nlp_rpi SEVERITY Information LOG LOG_DISCOVERY LOG_FCP verbose ACTION No action needed informational elx_mes0206 Nodev timeout on NPort lt nlp DID gt DESCRIPTION Mapped target has disappeared for longer than the timeout period DATA 1 nlp_flag 2 nlp_state 3 nlp_rpi SEVERITY Information LOG LOG_DISCOVERY verbose ACTION Check entries in proc scsi Ipfc to see if WWPNs exist for all targets If all targets are seen by the adapter but one or more targets are inaccessible by the system run the lun_scan script See the Linux tools link on the Linux section of the Emulex Web site to remap LUNs to scsi d
10. Emulex HBA Ipfec lun queue depth 30 1 128 Default max commands Yes sent to a single logical unit disk Ipfc topology 0 0x0 loop Fibre Channel link topology Yes then P2P defaults to loop if it fails 0x2 P2P only attempts point to point 0x4 loop only mode 0x6 P2P then loop Driver for Linux Configuration Section Page 17 Table 3 Ipfc Static Parameters Requires a driver reload to change Continued Variable Default Min Visible using sysfs Comments Ipfc_fcp_bind_method Specifies method of binding Yes each port Values 1 WWNN binding 2 WWPN binding 3 D ID binding 4 ALPA binding Ipfc fdmi on False 0 if disabled 1 or Yes 2 if enabled depending on type of support needed Ipfc scan down 0 Off 1 On Select method for scanning Yes ALPA to assign a SCSI ID Ipfc_max_luns 256 32768 Specifies the maximum Yes number of LUNs per target A value of 20 means LUNs from 0 to 19 are valid Ipfc multi ring support e Determines the number of No primary SLI rings over which to spread IOCB entries All Ipfc dynamic parameters are read write using sysfs Table 4 Ipfc Dynamic Parameters Do not require a driver reload to change Variable Default Min Max Comments Ipfc discovery min wait 3 0 60 The minimum number of seconds the driver waits for the dis
11. LOG_LIBDFC verbose ACTION None required elx_mes1608 libdfc get rev DESCRIPTION An application has requested the version of the ioctl module DATA 1 dfe major rev 2 dfc_minor_rev SEVERITY Warning LOG Always ACTION Only if applications report version mismatch failures verify Ipfc Ipfcdfc and libdfc are all compatible versions Driver for Linux Troubleshooting Section Page 53
12. informational elx_mes0111 Dropping received ELS cmd DESCRIPTION The driver decided to drop an ELS Response ring entry DATA 1 ulpStatus 2 ulpWord 4 SEVERITY Error LOG Always ACTION This error could indicate a software driver or firmware problem If problems persist report these errors to Technical Support Driver for Linux Troubleshooting Section Page 24 elx mes0112 ELS command lt elsCmd gt received from NPORT lt did gt DESCRIPTION Received the specific ELS command from a remote NPort DATA 1 hba_state SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0113 An FLOGI ELS command lt elsCmd gt was received from DID lt did gt in Loop Mode DESCRIPTION While in Loop Mode an unknown or unsupported ELS command was received DATA None SEVERITY Error LOG Always ACTION Check device DID elx mes0114 PLOGI chkparm OK DESCRIPTION Received a PLOGI from a remote NPORT and its Fibre Channel service parameters match this HBA Request can be accepted DATA 1 nlp_DID 2 nlp_state 3 nlp_flag 4 nlp_Rpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0115 Unknown ELS command lt elsCmd gt received from NPORT lt did gt DESCRIPTION Received an unsupported ELS command from a remote NPORT DATA None SEVERITY Error LOG Always ACTION Check remote NPORT for potential problem elx_mes0116 Xmit ELS
13. the Driver on Unsupported Linux Distributions eee 5 Upgrading the Kernel or Applying a Distribution Service Pack or Update 6 Installing the Driver Kit into an Upgraded Kernel ereenn 6 Installing the Utilities and the Application Helper Module 7 Prerequisk es nu oniknne danseren 7 Procedu eiiiai anenee AA AAAA RANEREN ENEAN EARANN a eae aes 7 Utilities Directory Structure rmananrnnnnvrrrrnnnnnnnnnnnnnrrnnnnnnenrrnnnnrrrnnnnenesennnnnnn 8 Installing the HBAnyware Utility with Web Launch eee 8 Prerequiskes russuseriemessndndndmen bunnen ddetttdtetet 8 Procedu OE A A 8 Installing the HBAnyware Security Configurator rnnrrrnnnnnnnnnnnnnvrrrnnnnnnnnrrrrnnnn 9 Prer quisites nnrnnnnnnnnknnnknnnknnnnnnnkannkannkannnnnnnnntueunuedddadeseeeddeeedededeeeeedete 9 ProCA O n A Anan E E EEEE TEENS 9 Installing HBAnyware and the Application Helper Module using the Upgrade Kernel ODIOM ena EAEE EEEE E SAER 9 Prorcgui oS roin ann na a E E G ES 9 Procedito La 9 Uninstalling the Driver Kit uuaannnnnnnnnnnnnnnnnnvnnnnvrnvnrrvnvrvevrrerrerrerrrrrrrrrrrrererrrrerenn 10 Uninstalling a Previous Application Helper Module Stand Alone Kit La 200 ites ies ceasaten A de 11 Uninstalling the Utilities 000 E 12 Uninstalling the HBAnyware Security Configurator ccccceeeceeteeeeeeeeeees 12 Uninstalling HBAnyware Web Launch Only ccccccceceeeeeeeeeeeeeeeeeeeeeeeteeetenees 12 Uninstalling HBAnywar
14. verbose ACTION No action needed informational elx_mes0133 FARP RSP received from DID lt did gt DESCRIPTION A FARP RSP has been received from the specified node DATA none SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0134 FARP REQ received from DID lt did gt DESCRIPTION A FARP REQ has been received from the specified node DATA none SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Link Discovery Events 0200 0299 elx_mes0200 CONFIG_LINK bad hba state lt hba state gt DESCRIPTION A CONFIG LINK mbox command completed and the driver was not in the right state DATA None SEVERITY Error LOG Always ACTION Software driver error If this problem persists report these errors to Technical Support elx mes0201 Abort outstanding I O on NPort lt Fabric DID gt DESCRIPTION All outstanding I Os are cleaned up on the specified remote NPort DATA None SEVERITY Information LOG LOG DISCOVERY verbose ACTION No action needed informational elx mes0202 Start Discovery hba state lt hba state gt DESCRIPTION Device discovery rediscovery after FLOGI FAN or RSCN has started DATA 1 fe flag 2 fo plogi cent 3 fo adisc cnt SEVERITY Information LOG LOG DISCOVERY verbose ACTION No action needed informational Driver for Linux Troubleshooting Section Page 27 elx mes0203 Nodev timeout on NPort lt nlp
15. 4 number of entries in the loop init LILP ALPA map An ALPA map message is also recorded if LINK EVENT verbose mode is set Each ALPA map message contains 16 ALPAs SEVERITY Error LOG Always ACTION If numerous link events are occurring check the physical connections to the Fibre Channel network elx mes1304 Link Up Event ALPA map DESCRIPTION A link up event was received DATA 1 wd1 2 wd2 3 wd3 4 wd4 SEVERITY Warning LOG LOG LINK EVENT verbose ACTION If numerous link events are occurring check the physical connections to the Fibre Channel network elx_mes1305 Link Down Event lt eventTag gt received DESCRIPTION A link down event was received DATA 1 fc eventTag 2 hba_state 3 fc_flag SEVERITY Error LOG Always ACTION If numerous link events are occurring check the physical connections to the Fibre Channel network elx_mes1307 READ_LA mbox error lt mbxStatus gt state lt hba_state gt DESCRIPTION The driver cannot determine what type of link event occurred DATA None SEVERITY Information LOG LOG_LINK_EVENT verbose ACTION If numerous link events are occurring check the physical connections to the Fibre Channel network May indicate a possible hardware or firmware problem Driver for Linux Troubleshooting Section Page 51 IOCTL Events 1600 1699 elx mes1600 libdfc debug entry DESCRIPTION The entry point for processing diagnostic ioctl DATA 1 Ipfc cmd 2 Ipfc arg1
16. ALPA based bind method used on an HBA which is not in a loop topology DATA 1 fe topology SEVERITY Warning LOG LOG DISCOVERY verbose ACTION Change the bind method configuration parameter of the HBA to 1 WWNN or 2 WWPN or 3 DID elx mes0246 RegLogin failed DESCRIPTION The firmware returned a failure for the specified RegLogin DATA Did mbxStatus hbaState SEVERITY Error LOG Always ACTION This message indicates that the firmware could not do RegLogin for the specified Did There may be a limitation on how many nodes an HBA can see elx mes0247 Start Discovery Timer state lt hba state gt DESCRIPTION Start the device discovery RSCN rescue timer DATA 1 tmo 2 fe_disctmo 3 fc_plogi_cnt 4 fc adisc cent SEVERITY Information LOG LOG DISCOVERY verbose ACTION No action needed informational elx_mes0248 Cancel Discovery Timer state lt hba_state gt DESCRIPTION Cancel the device discovery RSCN rescue timer DATA 1 fe flag 2 fc_plogi_cnt 3 fo adisc cnt SEVERITY Information LOG LOG DISCOVERY verbose ACTION No action needed informational elx_mes0249 All d target ids in use Bind creation failed DESCRIPTION The driver has used all available target ids Target to node binding has failed DATA 1 Maximum number of supported targets SEVERITY Error LOG Always ACTION Check the SAN configuration Driver for Linux Troubleshooting Section Page 34 elx mes0252 Rescanning
17. Always ACTION Check Fabric configuration The driver recovers from this and continues with device discovery Driver for Linux Troubleshooting Section Page 30 elx mes0223 Timeout while waiting for NameServer login DESCRIPTION Our login request to the NameServer was not acknowledged within RATOV DATA None SEVERITY Error LOG Always ACTION Check the fabric configuration The driver recovers from this and continues with device discovery elx_mes0224 NameServer Query timeout DESCRIPTION Node authentication timeout node Discovery timeout A NameServer Query to the Fabric or discovery of reported remote NPorts is not acknowledged within R_A_TOV DATA 1 fe ns retry 2 fc max ns retry SEVERITY Error LOG Always ACTION Check Fabric configuration The driver recovers from this and continues with device discovery elx mes0225 Device Discovery completes DESCRIPTION This indicates successful completion of device re discovery after a link up DATA None SEVERITY Information LOG LOG DISCOVERY verbose ACTION No action needed informational elx_mes0226 Device discovery completion error DESCRIPTION This indicates that an uncorrectable error was encountered during device re discovery after a link up Fibre Channel devices will not be accessible if this message is displayed DATA None SEVERITY Error LOG Always ACTION Reboot the system If the problem persists report the error to Technical Support Run w
18. Application Helper Module using the Upgrade Kernel Option If you wish you can install the Applications Kit on an upgraded kernel The Applications Kit contains HBAnyware and the Application Helper Module Prerequisites The Ipfc driver must be part of the target kernel distribution e The utilities package was previously installed on the current kernel Procedure To install the Applications Kit on an upgraded kernel Boot to the new kernel Log on as root Change use the cd command to the directory containing the unpacked Applications Kit Run the install upgrade kernel script Type pe eo install upgradekernel Driver for Linux Installation Section Page 9 Uninstalling the Driver Kit Note Driver parameter changes made using HBAnyware or etc modprobe conf persist if the driver is uninstalled To return to the default settings you must modify the settings in etc modprobe conf Note You must run the uninstall script that shipped with the version of the driver kit you want to remove If the uninstall script resides in the usr src directory be sure to copy it to a temporary directory before you run it This section describes how to uninstall a previous version of the Emulex 8 x driver for Linux The uninstall procedure automatically restores the archived Ipfc driver To uninstall the Ipfc driver Log on as root 2 If possible exit all applications that use Fibre Channel attached drives t
19. EVERITY Error LOG Always ACTION This is a software driver error If this problem persists report these errors to Technical Support FCP Traffic History 0700 0799 elx mes701 Issue Abort Task Set to TGT lt num gt LUN lt num gt DESCRIPTION The SCSI layer detected that it needs to abort all I O to a specific device This causes the FCP Task Management command to abort the I O in progress DATA 1 rpi 2 flags SEVERITY Information LOG LOG_FCP verbose ACTION Check the state of the device in question elx mes0702 Issue Target Reset to TGT lt num gt DESCRIPTION The SCSI layer detected that it needs to abort all I O to a specific target This results in an FCP Task Management command to abort the I O in progress DATA 1 rpi 2 flags SEVERITY Information LOG LOG FCP verbose ACTION Check the state of the target in question elx mes0703 Issue LUN Reset to TGT lt num gt LUN lt num gt DESCRIPTION The SCSI layer detected that it must abort all I O to a specific device This results in an FCP Task Management command to abort the I O in progress DATA 1 rpi 2 flags SEVERITY Information LOG LOG_FCP verbose ACTION Check the state of the device in question elx_mes0710 lodone lt target gt lt lun gt cmd lt cmd gt error lt result gt SNS lt Ip gt lt Ip3 gt DESCRIPTION This error indicates that the Fibre Channel driver is returning a SCSI command to the SCSI layer in error or with sen
20. ITY Warning LOG LOG_FCP verbose ACTION If the problem persists please check the targets for errors elx_mes0729 FCP cmd lt cmnd gt failed lt target gt lt lun gt status lt status gt result lt result gt DESCRIPTION The specifed device failed an FCP command DATA 1 ulpContext 2 iotag SEVERITY Warning LOG LOG_FCP verbose ACTION Check the state of the target in question elx_mes0730 FCP command failed RSP DESCRIPTION The FCP command failed with a response error DATA 1 resp info 2 scsi_status 3 Resld 4 SnsLen 5 RspLen 6 rspinfo3 SEVERITY Warning LOG LOG_FCP verbose ACTION Check the state of the target in question elx_mes0734 FCP read check error DESCRIPTION The issued FCP command returned a read check error DATA 1 fcpDI 2 rspResld 3 fcpi parm 4 cmd 0 SEVERITY Warning LOG LOG_FCP verbose ACTION Check the state of the target in question elx_mes0748 Abort handler timed out waiting for abort to complete DESCRIPTION The abort handler timed out waiting for abort to complete DATA 1 ret 2 id 3 lun 4 snum SEVERITY Error LOG Always ACTION None required elx_mes0749 SCSI layer issued abort device DESCRIPTION The SCSI layer aborted a device DATA 1 ret 2 id 3 lun 4 snum SEVERITY Warning LOG LOG_FCP verbose ACTION None required Driver for Linux Troubleshooting Section Page 47 Node Table Events 0900 0999 elx_mes0900 Clea
21. Machine is processing an event DATA 1 nlp_flag SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0212 DSM out state lt rc gt on NPort lt nlp_DID gt DESCRIPTION The driver Discovery State Machine completed processing an event DATA 1 nlp_flag SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0213 Reassign scsi id lt nlp_sid gt to NPort lt nlp_DID gt DESCRIPTION A previously bound FCP Target has been rediscovered and reassigned a scsi id DATA 1 nlp_bind_type 2 nlp_flag 3 nlp_state 4 nlp_rpi SEVERITY Information LOG LOG_DISCOVERY LOG_FCP verbose ACTION No action needed informational elx_mes0214 RSCN received DESCRIPTION An RSCN ELS command was received from a fabric DATA 1 fe flag 2 payload len 3 Ip 4 fe_rscn_id_cnt SEVERITY Information LOG LOG DISCOVERY verbose ACTION No action needed informational elx mes0215 RSCN processed DESCRIPTION An RSCN ELS command was received from a fabric and processed DATA 1 fe flag 2 cnt 3 fe_rscn_id_cnt 4 hba_state SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Driver for Linux Troubleshooting Section Page 29 elx_mes0216 Assign scsi id lt nIp sid gt to NPort lt nlp DID gt DESCRIPTION A scsi id is assigned due to BIND ALPA DATA 1 nlp bind type 2 nlp flag 3 nlp state 4
22. ON None required Driver for Linux Troubleshooting Section Page 48 elx mes0910 FIND node DID unmapped DESCRIPTION The driver is searching for a node table entry on the unmapped node list based on the SCSI ID DATA 1 ndlp 2 nlp DID 3 nlp flag 4 data1 SEVERITY Information LOG LOG NODE verbose ACTION None required elx mes0911 FIND node DID unmapped DESCRIPTION The driver is searching for a node table entry on the unmapped node list based on DID DATA 1 ndlp 2 nlp DID 3 nlp flag 4 data1 SEVERITY Information LOG LOG NODE verbose ACTION None required elx mes0929 FIND node DID unmapped DESCRIPTION The driver is searching for a node table entry on the unmapped node list based on DID DATA 1 ndlp 2 nlp DID 3 nlp flag 4 data1 SEVERITY Information LOG LOG NODE verbose ACTION None required elx mes0930 FIND node DID mapped DESCRIPTION The driver is searching for a node table entry on the mapped node list based on DID DATA 1 ndlp 2 nlp DID 3 nlp flag 4 data1 SEVERITY Information LOG LOG NODE verbose ACTION None required elx mes0931 FIND node DID adisc DESCRIPTION The driver is searching for a node table entry on the binding list based on DID DATA 1 ndlp 2 nlp DID 3 nlp flag 4 data1 SEVERITY Information LOG LOG NODE verbose ACTION None required elx mes0932 FIND node did lt did gt NOT FOUND DESCRIPTION The driver was searchin
23. RIPTION An I O tag cannot be assigned because none are available The maximum number of allowed I Os are currently outstanding DATA None SEVERITY Error LOG Always ACTION This message indicates the adapter HBA I O queue is full Typically this happens when heavy I O is running on a low end 3 digit adapter We suggest you upgrade to a higher end adapter elx_mes0319 READ_SPARAM mbxStatus error lt mbxStatus gt hba state lt hba_state gt DESCRIPTION The driver issued a READ SPARAM mbox command to the HBA that failed DATA None SEVERITY Error LOG Always ACTION This error could indicate a firmware or hardware problem Report these errors to Technical Support elx_mes0320 CLEAR_LA mbxStatus error lt mbxStatus gt hba state lt hba_state gt DESCRIPTION The driver issued a CLEAR_LA mbox command to the HBA that failed DATA None SEVERITY Error LOG Always ACTION This error could indicate a firmware or hardware problem Report these errors to Technical Support elx_mes0321 Unknown IOCB command DESCRIPTION Received an unknown IOCB command completion DATA 1 ulpCommand 2 ulpStatus 3 ulploTag 4 ulpContext SEVERITY Error LOG Always ACTION This error could indicate a software driver or firmware problem If these problems persist report these errors to Technical Support elx_mes0322 Ring lt ringno gt handler unexpected completion loTag lt loTag gt DESCRIPTION The driver could not find a
24. RIPTION Device discovery is in progress DATA 1 fe plogi cnt 2 fc flag 3 phba gt hba state SEVERITY Information LOG LOG DISCOVERY verbose ACTION No action needed informational elx_mes0234 ReDiscovery RSCN DESCRIPTION The number type of RSCNs has forced the driver to go to the nameserver and re discover all NPORTs DATA 1 fc rscn id cnt 2 fc_flag 3 hba_state SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0235 Deferred RSCN DESCRIPTION The driver has received multiple RSCNs and has deferred the processing of the most recent RSCN DATA 1 fc rscn id cnt 2 fc_flag 3 hba_state SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Driver for Linux Troubleshooting Section Page 32 elx mes0236 NameServer req DESCRIPTION The driver is issuing a NameServer request to the fabric DATA 1 cmdcode 2 fc flag 3 fe rscn id cnt SEVERITY Information LOG LOG DISCOVERY verbose ACTION No action needed informational elx_mes0237 Pending Link Event during Discovery State lt hba_state gt DESCRIPTION Received link event during discovery Causes discovery restart DATA None SEVERITY Warning LOG LOG_DISCOVERY verbose ACTION None required unless problem persists If persistent check cabling elx_mes0238 Process lt Did gt NameServer Rsp DESCRIPTION The driver received a NameServer response
25. X EMULEX Emulex Driver for Linux Version 8 0 16 34 User Manual Last updated October 24 2007 Copyright 2007 Emulex Corporation All rights reserved worldwide No part of this document may be reproduced by any means nor translated to any electronic medium without the written consent of Emulex Corporation Information furnished by Emulex Corporation is believed to be accurate and reliable However no responsibility is assumed by Emulex Corporation for its use or for any infringements of patents or other rights of third parties which may result from its use No license is granted by implication or otherwise under any patent or patent rights of Emulex Corporation Emulex AutoPilot Installer BlockGuard cLAN FabricStream FibreSpy Giganet HBAnyware InSpeed IntraLink LightPulse MultiPulse SAN Insite SBOD and Vixel are registered trademarks and AutoPilot Manager EZPilot SLI and VMPilot are trademarks of Emulex Corporation All other brand or product names referenced herein are trademarks or registered trademarks of their respective companies or organizations Emulex provides this manual as is without any warranty of any kind either expressed or implied including but not limited to the implied warranties of merchantability or fitness for a particular purpose Emulex Corporation may make improvements and changes to the product described in this manual at any time and without any notice Emulex Corporation assumes no responsibilit
26. ad the driver kit from the Emulex web site or copy it to the system from the installation CD 6 Log on as root to a terminal and unpack the tarball with the following command tar xzf lpfc 2 6 driver kit lt driver version gt tar gz 7 Change to the directory that is extracted cd lpfc 2 6 driver kit lt driver version gt 8 Execute the Ipfc install script with no options to install the new driver kit Type lpfc install 9 Reboot the system to complete re installation of the Emulex driver Driver for Linux Installation Section Page 6 Installing the Utilities and the Application Helper Module Follow these instructions to install the HBAnyware configuration utility and the Application Helper Module on your system For ease of installation HBAnyware and the Application Helper Module are bundled together The elxIpfc init script is also installed and configured to start and stop the Ipfcdfc driver during system startup and shutdown Prerequisites The Ipfc driver must be installed e Previous versions of the Application Helper Module must be uninstalled Note You must run the uninstall script that shipped with the version of the Application Helper Module you want to remove If the uninstall script resides in the usr src directory be sure to copy it to a temporary directory before you run it Procedure To install HBAnyware and the Application Helper Module Log on as root 2 Download the utilit
27. alization failed when issuing a CFG_RING mailbox command DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support Driver for Linux Troubleshooting Section Page 42 EMULEX elx_mes0447 Adapter failed init moxCmd lt mbxCommand gt CONFIG_LINK mbxStatus lt mbxStatus gt DESCRIPTION Adapter initialization failed when issuing a CONFIG_LINK mailbox command DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0448 Adapter failed to init moxCmd lt mbxCommand gt READ_SPARM mbxStatus lt mbxStatus gt DESCRIPTION Adapter initialization failed when issuing a READ_SPARM mailbox command DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0449 lpfc_ attr attribute cannot be initialized to d allowed range is min max DESCRIPTION Sysfs attribute value written exceeds attribute range DATA 1 attribute name 2 value written 3 minimum value 3 maximum value SEVERITY Error LOG Always ACTION Write a value within the supported range elx_mes0450 Ipfc attr attribute cannot be set to d allowed range is min max DESCRIPTION Sysfs attribute v
28. all script with the uninstall option Type tmp ioctl install uninstall 6 If prompted reboot the system Driver for Linux Installation Section Page 11 Uninstalling the Utilities Follow these instructions to uninstall the utility and the Application Helper Module Note If the HBAnyware Security Configurator is installed it must be uninstalled before uninstalling HBAnyware Uninstalling the HBAnyware Security Configurator Note You must run the uninstall script that shipped with the version of HBAnyware Security Configurator you want to remove If the uninstall script resides in the usr src directory be sure to copy it to a temporary directory before you run it To install the HBAnyware Security Configurator 1 Logon as root 2 Change use cd command to the directory to which you copied the tar file during installation 3 Run the uninstall script with the ssc parameter specified Type uninstall ssc Uninstalling HBAnyware Web Launch only Note If you installed HBAnyware Web Launch you must uninstall it before uninstalling HBAnyware To uninstall HBAnyware Web Launch only 1 Logon as root 2 Execute the following script usr sbin hbanyware wsuninstall This script stops the HBAnyware Web Launch Service daemons if they are running and removes all Web Launch related files from the host Uninstalling HBAnyware and the Application Helper Module Note You must run the
29. alue written exceeds attribute range DATA 1 attribute name 2 value written 3 minimum value 3 maximum value SEVERITY Error LOG Always ACTION Write a value within the supported range elx_mes0451 Enable interrupt handler failed DESCRIPTION The driver attempted to register the HBA interrupt service routine with the host operating system but failed DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or driver problem If the problem persists report the error to Technical Support elx_mes0452 Waiting for discovery to stop Data x x x x x x x x DESCRIPTION The driver has configured the HBA succesfully and is waiting for FC discovery to complete Message repeats every 30 seconds DATA 1 Current HBA state 2 Current HBA flags 3 Current SLI flags 4 Number of outstanding PRLIs SEVERITY Error LOG Always ACTION May be a storage device issue or switch issue Check your SAN configuration Driver for Linux Troubleshooting Section Page 43 elx_mes0453 Adapter failed to init moxCmd lt mbxCommand gt READ CONFIG mbxStatus lt mbxStatus gt DESCRIPTION Adapter initialization failed when issuing a READ_CONFIG mailbox command DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0454 Adapter failed to init moxCmd lt mbxCommand gt INIT LINK mbxSta
30. bose ACTION If the problem persists check the targets If the targets are okay report the error to Technical Support elx_mes0327 Waited lt msecs gt mSecs for high priority IOCB lt iocb gt giving up DESCRIPTION A high priority IOCB such as a target reset or lun reset was issued and did not complete in the required amount of time DATA None SEVERITY Error LOG Always ACTION This message indicates a reset could not complete in the expected amount of time If problems persist report these errors to Technical Support elx_mes0328 Restart HBA Data x x x x DESCRIPTION A board reset is getting issued to the HBA DATA 1 Current HBA state 2 Current SLI state SEVERITY Information LOG LOG_SLI verbose ACTION None General information Driver for Linux Troubleshooting Section Page 40 elx mes0329 Kill HBA Data x x x x DESCRIPTION A kill board command is getting sent to the HBA DATA 1 Current HBA state 2 Current SLI state SEVERITY Information LOG LOG_SLI verbose ACTION None General information Initialization Events 0400 0499 elx_mes0405 Service Level Interface SLI 2 selected DESCRIPTION A CONFIG_PORT SLI2 mailbox command was issued DATA None SEVERITY Information LOG LOG_INIT verbose ACTION No action needed informational elx_mes0410 Cannot find virtual addr for mapped buf on ring lt ringno gt DESCRIPTION The driver cannot find the specified buffer in its mapping tabl
31. c driver on an unsupported distribution of Linux refer to the distribution s Web site or http kernel org Driver for Linux Installation Section Page 5 Upgrading the Kernel or Applying a Distribution Service Pack or Update You can install the driver kit into an upgraded kernel The installation of a Red Hat Enterprise Linux update or SuSE Linux Enterprise Server service pack generally involves updating the kernel Note Some distribution service packs or updates contain an Emulex driver If the driver version contained in the distribution or service pack is the same version or newer than the currently installed driver kit re installation of the driver kit may not be necessary Note The Ipfc install script does not support custom kernels For example kernels with Version_Release strings that do not match those of the original distribution kernel Note Follow these steps before installing a new Update CD to a Red Hat Enterprise Linux distribution or applying a service pack to a SuSE Linux Enterprise Server distribution Installing the Driver Kit into an Upgraded Kernel To install the driver kit into an upgraded kernel 1 Copy the Ipfc install script to the temporary directory For example cp usr src lpfc lpfc install tmp 2 Execute the Ipfc install script with the uninstall option Type tmp lpfc install uninstall 3 Upgrade the kernel and or distribution Reboot the system with the new kernel Downlo
32. command lt elsCmd gt to remote NPORT lt did gt DESCRIPTION Xmit ELS command to remote NPORT DATA 1 icmd gt ulploTag 2 hba_state SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0117 Xmit ELS response lt elsCmd gt to remote NPORT lt did gt DESCRIPTION Xmit ELS response to remote NPORT DATA 1 icmd gt ulploTag 2 size SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0119 Issue GEN REQ IOCB for NPORT lt ulpWord 5 gt DESCRIPTION Issue a GEN REQ IOCB for remote NPORT These are typically used for CT request DATA 1 ulploTag 2 hba_state SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Driver for Linux Troubleshooting Section Page 25 elx mes0121 PLOGI chkparm OK DESCRIPTION Received a PLOGI from a remote NPORT and its Fibre Channel service parameters match this HBA Request can be accepted DATA 1 nlp_DID 2 nlp_state 3 nlp_flag 4 nlp_Rpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0127 ELS timeout DESCRIPTION An ELS IOCB command was posted to a ring and did not complete within ULP timeout seconds DATA 1 elscmd 2 remote id 3 ulpcommand 4 ulploTag SEVERITY Error LOG Always ACTION If no ELS command is going through the adapter reboot the system If problem persists contact Technical Support
33. covery to complete Ipfc discovery wait limit 600 0 600 The maximum number of seconds the special driver waits for the discovery to value complete meaning no limit Ipfc_linkup_wait_limit 15 0 60 The number of seconds the driver waits for the link to come up Ipfc log verbose 0x0 0x0 Oxffff bit mask Extra activity logging Ipfc nodev tmo 30 0 255 Seconds to hold I O err if device disappears Ipfc use adisc 0 0 Off 1 On Send ADISC instead of PLOGI for device discovery or RSCN Driver for Linux Configuration Section Page 18 Table 5 Ipfedfc Static Parameters Variable Default Min Max Comments Ipfc_scsi_req_tmo 30 0 255 Time out value in seconds for SCSI request sent through Ipfcdfc module Not available using the HBAnyware GUI HBACMD Command line only Using udev for Persistent Naming The udev tool is included in RHEL 4 and SLES 9 SP1 and can be configured to provide persistent names for SCSI drives SLES 9 On SLES 9 SP1 udev is configured by default to create persistent device names for each disk and partition in the dev disk by id directory These names are symbolic links to the current dev sd block device The names are derived from information retrieved from the disk itself and will therefore follow the disk even if it s dev sd name changes For example sles9 Is dev disk by id total 8 drwxr xr x 2 root root 4096 Mar 3 21 33 drwxr xr x 4 root root 4096 Feb 10
34. d reboot the system for the changes to take effect Table 3 Ipfc Static Parameters Requires a driver reload to change Visible Variable Default Min Max Comments using sysfs Ipfc_ackO 0 0 Off 1 On Use ACKO for class 2 Yes Ipfc cr count 1 1 255 This parameter determines No the values for I O coalescing for cr delay msec or cr count outstanding commands Driver for Linux Configuration Section Page 16 Table 3 Ipfc Static Parameters Requires a driver reload to change Continued Visible Variable Default Min Max Comments using sysfs Ipfc cr delay 0 0 63 This parameter determines No the values for I O coalescing for cr_delay msec or cr_count outstanding commands Ipfc discovery threads 32 1 64 Specifies the maximum No number of ELS commands that can be outstanding for a discovery Note The discovery threads parameter will default to a value of 64 for private loop topologies regardless of the configured value If there are multiple ports configured on the host the value of 64 will only be used for those ports that are connected in a private loop topology The configured value will be used for all other ports Ipfc fep class 3 2 3 Fibre Channel class for Yes FCP data transmission Ipfc link speed 0 0 auto select Sets link speed Yes 1 1G 2 2G 4 4G Ipfec hba queue depth 8192 32 8192 Maximum number of FCP Yes commands that can queue to an
35. devices such as all disks made by Seagate by adding this line to etc scsi_id vendor SEAGATE options g Then load or reload the Ipfc driver udev creates symbolic links for each SCSI disk and its partitions For example rhel4 Is I dev disk Irwxrwxrwx 1 root root 3 Mar 7 00 06 dev disk 32000000c507985c4 gt sdb Irwxrwxrwx 1 root root 3 Mar 7 00 06 dev disk 32000000c50797d92 gt sdc Irwxrwxrwx 1 root root 4 Mar 7 00 06 dev disk 32000000c50797d921 gt sdc1 Irwxrwxrwx 1 root root 3 Mar 7 00 06 dev disk 32000000c507985bb gt sdd Irwxrwxrwx 1 root root 4 Mar 7 00 06 dev disk 32000000c507985bb1 gt sdd1 Irwxrwxrwx 1 root root 4 Mar 7 00 06 dev disk 32000000c507985bb2 gt sdd2 For further information about udev consult the following resources udev Web Page http www kernel org pub linux utils kernel hotplug udev htmi Kernel Korner udev Persistent Device Naming in User Space Linux Journal article by Greg Kroah Hartman http www linuxjournal com article php sid 7316 Writing udev rules by Daniel Drake http www reactivated net writing_udev_rules html Driver for Linux Configuration Section Page 20 Troubleshooting Introduction This section describes log messages which can be useful when troubleshooting the Emulx driver for Linux Log messages are organized into logical groups based on code functionality within the Fibre Channel driver Each group consists of a block of 100 log message numbers Most gr
36. disk image will be needed See Creating a New Ramdisk Image on page 15 to learn how The driver parameters are specified in etc modprobe conf via the options command For example the following sets the verbose flag options lpfc lpfc log verbose 0xffff If the same option is specified in both the etc modprobe conf and on the modprobe command line the option setting in the etc modprobe conf file takes precedence Temporary Driver Configuration by Read Write to sysfs Sysfs is a virtual filesystem that exposes the structure of the system to the user It also includes interfaces to driver parameters through which the driver parameters can be viewed and modified Since these interfaces are available only after driver load only those parameters that can be modified dynamically can be changed in this manner Nevertheless all driver parameters can be read through sysfs It is important to note that sysfs changes exist only for the lifetime of the driver load and are lost on driver unload or reboot The sysfs filesystem is mounted and available as sys We must first identify the scsi host which represents the HBA for which we wish to modify the driver parameters All scsi hosts bound to the Ipfc driver can be viewed with the following command ls d sys bus pci drivers lpfc host Assuming we are interested in HBA scsi_host 7 we can list the driver parameters for this particular HBA as ls 1 sys class scsi_host host7 lpfc An
37. e DESCRIPTION An ELS FLOGI command that was sent to the fabric failed DATA 1 ulpStatus 2 ulpWord 4 SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0101 FLOGI completes successfully DESCRIPTION An ELS FLOGI command that was sent to the fabric succeeded DATA 1 ulpWord 4 2 e_d_tov 3 r_a_tov 4 edtovResolution SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0102 PLOGI completes to NPort lt nlp DID gt DESCRIPTION The HBA performed a PLOGI into a remote NPort DATA 1 ulpStatus 2 ulpWord 4 3 disc 4 num_disc_nodes SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0103 PRLI completes to NPort lt nlp DID gt DESCRIPTION The HBA performed a PRLI into a remote NPort DATA 1 ulpStatus 2 ulpWord 4 3 num_disc_nodes SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0104 ADISC completes to NPort lt nlp DID gt DESCRIPTION The HBA performed a ADISC into a remote NPort DATA 1 ulpStatus 2 ulpWord 4 3 disc 4 num_disc_nodes SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0105 LOGO completes to NPort lt nlp_DID gt DESCRIPTION The HBA performed a LOGO to a remote NPort DATA 1 ulpStatus 2 ulpWord 4 3 num_disc_nodes SEVERITY Information LOG LOG_ELS verb
38. e Thus it cannot find the virtual address needed to access the data DATA 1 phys 2 next 3 prev 4 postbufq cnt SEVERITY Error LOG Always ACTION This error could indicate a software driver or firmware problem If problems persist report these errors to Technical Support elx_mes0436 Adapter failed to init timeout status reg lt status gt DESCRIPTION The adapter failed during powerup diagnostics after it was reset DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0437 Adapter failed to init chipset status reg lt status gt DESCRIPTION The adapter failed during powerup diagnostics after it was reset DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0438 Adapter failed to init chipset status reg lt status gt DESCRIPTION The adapter failed during powerup diagnostics after it was reset DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support Driver for Linux Troubleshooting Section Page 41 elx_mes0439 Adapter failed to init moxCmd lt mbxCommand gt READ REV mbxStatus lt mbxStatus gt DESCRIPTION Adapter initialization fail
39. e and the Application Helper Module 008 12 Configuration sueasesaedoebeene nnmnnn nnmnnn 13 Driver Configuration Methods Using modprobe and et modprobe6 conf ce ee ee e RRR 13 Temporary Configuration Method uuarrrnnnvrrrnnnnnnnrnnnnrrrnnnnnnnnrnnnnnrrnnnnnnenn 13 Persistent Configuration Method rrrnnnnnnnnnnnvrrnnnnnnnnnnnnnrrrnenennnnrnnnnnrrnnnn 14 Temporary Driver Configuration by Read Write to sysfs ccceeeeeeeeeeeeees 14 Creating a New Ramdisk Image rrnnnnvrrrnnnnnnvnnnnnvrrrnnnnnnnrnnnnnrrrnnnnnnnrnnnnnnrnnnnn 15 For Installed Ipfc Driver Kits mmrrnrrnrrvrrvrrrvrrrvvrvvrrrerrrrrrrrrrrrrrrrrrerrrrrrreree 15 For Distribution In Box Ipfc Drivers rvvrvrvrrvrrrvvnnnrrvrrrrrrrrrrrrrerrrrrerrereer 15 Dynamically Adding LUNs and TargetS snnnnnnnonnnnnnnnvnvnvnnnrvnnnrnvrvrnvrrrrrrrrrererenr 15 Driver Parameters Reference Table uunnnnnnnnnnnnnnnnnnnvvnvnnnnnvnnnnnrnrrrnrrrrrrrrrererenr 16 Using udev for Persistent Naming evvvvnnnnnnnnvvnvvnnvnvnvnrrrrerrrrrrrrrrrrrererrrrereernr 19 Driver for Linux User Manual Page iii SPES eee ct aeasee a cc cs ce ee ot case ce cece nek cae cee eco ee ot cae esterases 19 RHEL 4 oun cece eeccccecee cece ee eeeeecaeee eee eeeeeeceaaaeeeeeeeeeeecaaaeeeeeeeecgecccaeeeeeeeeseeeenaaees 19 Enable sosi cies pesneteneeeeeteateanetentheniheathansheaguanehentiaastaaatasatanass 19 TFOUDIESHOOUNGuunsoenssmneinnakneiskndenaaskdeniekanb
40. eature in RHEL 4 Driver for Linux Installation Section Page 2 Known Issues Some Web browsers attempt to continually reload the HBAnyware online help rendering it unusable In this case disable the Web browser s JavaScript capability Refer to the Web browser s documentation for instructions Driver for Linux Installation Section Page 3 Installing the Driver Kit The Ipfc install script installs the Ipfcdriver 2 6 RPM The RPM Installs the driver sources to the usr src lpfc directory Builds the driver for the currently running kernel Installs the driver to the proper directory for the currently running kernel Once the RPM is installed the Ipfc install script creates a new ramdisk for the currently running kernel so that the Ipfc driver is loaded when the kernel is initialized during system startup Note You must uninstall any previous Ipfc driver kits and or Application Helper Modules that were installed from the Emulex CD or downloaded from the Emulex Web site i e not part of a distribution before installing this driver kit This installation will fail if a previous version of the Ipfc driver or the Application Helper Module is detected Refer to Uninstalling the Driver Kit on page 10 Uninstalling a Previous Application Helper Module Stand Alone Kit on page 11 and Uninstalling the Utilities on page 12 for more information When invoked without options the pfc install script a
41. ed when issuing a READ_REV mailbox command DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0440 Adapter failed to init moxCmd lt mbxCommand gt READ REV detected outdated firmware DESCRIPTION Outdated firmware was detected during initialization DATA 1 read_rev_reset SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem Update the firmware If the problem persists report the error to Technical Support elx_mes0441 VPD not present on adapter mbxCmd lt mbxCommand gt DUMP VPD mbxStatus lt mbxStatus gt DESCRIPTION The DUMP_VPD mailbox command failed DATA None SEVERITY Information LOG LOG_INIT verbose ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0442 Adapter failed to init moxCmd lt mbxCommand gt CONFIG_PORT mbxStatus lt mbxStatus gt DESCRIPTION Adapter initialization failed when issuing a CONFIG_PORT mailbox command DATA 1 hbainit SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0446 Adapter failed to init moxCmd lt mbxCommand gt CFG_RING mbxStatus lt mbxStatus gt ring lt num gt DESCRIPTION Adapter initi
42. ede takke kennnnkk ne hdd Gen 21 Taie eii et e a EEE 21 Severity Codes rrrnnnnnanannnnnnrrnnnnnnannnnnnnrrrnnnnensnnnnnnnrrnnnnnessnnnnnnnrrnnnensennnnnnnnnnene 21 Message Group Masks rrrnnnnnnnnnnnnnrrrnnnnnnnrnnnnnrrnnnnnnnnrnnnnnrrnnnnensnrnnnrnneenesrnnnnnnn 21 Message Log Example ccccccccccceccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 22 ELS Events 0100 0199 nirien a AATE TEA 23 Link Discovery Events 0200 0299 rrrnnnnnnnnnvvnvvnnvvvvvrvrvrvnnnvnrnvnnnnnnnnrnnnnnnseer 27 Mailbox Events 0300 0399 rrnnnnnnnnnnnnnnnnnvnnrrrrrrrrrrrrrrrrerrerrrerrrrrrrrererererereeen 36 Initialization Events 0400 0499 ueeennnnnnnnnnnnvrvrnvnvnvrvrrrrrrrrrrrrrrrrrrrrerererrrererene 41 FCP Traffic History 0700 0799 rnnnnnnnnnvrrnnnnnnnnrnnnnnrrrnnnnnnnrnnnnnrrrnnnnnnnernnnnnen 45 Node Table Events 0900 0999 urrnnnnnnnnnnnnnnvvrrererrerrrererrrrrrrrrrrrrrrererrrrrereren 48 Miscellaneous Events 1200 1299 000 i ii eee 50 Link Events 1300 1399 ccs ce cae tic cece kel ketene 50 IOCTL Events 1600 T699 irsinin aaiae 52 Driver for Linux User Manual Page iv Installation Driver Information Supported Features e Topology support Fibre Channel Arbitrated Loop FC AL point to point fabric with auto topology negotiation e Supports 1 2 and 4 gigabit Gb with auto rate negotiation e Protocols SCSI FCP FCP 2 FC Tape profile including use of ADISC instead of PLOGI FC i
43. efinition LOG_ELS ELx 0100 0199 0x1 ELS events LOG_DISCOVERY DIx 0200 0299 0x2 Link discovery events Driver for Linux Troubleshooting Section Page 21 Table 7 Message Log Table Continued LOG Message Preamble p Verbose Mask String From To de Verbose Description eens it Definition LOG_MBOX MBx 0300 0399 0x4 Mailbox events LOG INIT INx 0400 0499 0x8 Initialization events Future 0500 0599 LOG_FCP FPx 0700 0799 0x40 FCP traffic history Future 0800 0899 LOG_NODE NDx 0900 0999 0x80 Node table events Reserved 1000 1099 0x100 LOG_MISC MIx 1200 1299 0x400 Miscellaneous events LOG_LINK_EVENT LKx 1300 1399 0x10 Link events IOCTL_ERROR IOx 1600 1699 0x2000 IOCTL events LOG ALL MSG Ox1 fff Log all messages Message Log Example The following is an example of a LOG message Jul 12 16 30 26 lt node gt kernel completes In the above LOG message e IpfcO identifies the LOG message as coming from EMULEX HBAO 0234 identifies the LOG message number e Dli identifies the LOG message as a DISCOVERY DI INFORMATION i message lpfc0 0234 DIi Device Discovery Note If the word Data is present in a LOG message any information to the right of Data is intended for Emulex technical support engineering use only Driver for Linux Troubleshooting Section Page 22 ELS Events 0100 0199 elx mes0100 FLOGI failur
44. evices in the midlayer If a device has not been rediscovered but other targets are seen by that adapter check the target device If no targets are visible to the adapter check for link on the adapter and that the fabric has not failed elx mes0207 target id d out of range DESCRIPTION The target id is beyond the supported driver range DATA 1 target id SEVERITY Error LOG Always ACTION Check the SAN configuration elx_mes0208 Failmask change on NPort lt nlp_DID gt DESCRIPTION An event was processed that indicates the driver may not be able to communicate with the remote NPort DATA 1 nlp_failMask 2 bitmask 3 flag SEVERITY Information LOG LOG DISCOVERY verbose ACTION No action needed informational Driver for Linux Troubleshooting Section Page 28 elx mes0209 RFT request completes ulpStatus lt ulpStatus gt CmdRsp lt CmdRsp gt DESCRIPTION A RFT request that was sent to the fabric completed DATA None SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0210 Continue discovery with lt num disc nodes gt ADISCs to go DESCRIPTION A device discovery is in progress DATA 1 fe adisc cnt 2 fc_flag 3 phba gt hba_state SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0211 DSM in event lt evt gt on NPort lt nlp_DID gt in state lt cur_state gt DESCRIPTION The driver Discovery State
45. example output is as follows r r r 1 root root 4096 Feb 28 17 03 sys class scsi host host7 Ipfc ackO rw r r 1 root root 4096 Feb 28 17 03 sys class scsi_host host7 lpfc_fcp_bind_method r r r 1 root root 4096 Feb 28 17 03 sys class scsi_host host7 lpfc_fcp_class rw r r 1 root root 4096 Feb 28 17 03 sys class scsi host host7 Ipfc fdmi on r r r 1 root root 4096 Feb 28 17 03 sys class scsi host host7 Ipfc link speed rw r r 1 root root 4096 Feb 28 15 34 sys class scsi host host7 Ipfc log verbose r r r 1 root root 4096 Feb 28 17 03 sys class scsi host host7 Ipfc lun queue depth rw r r 1 root root 4096 Feb 28 17 03 sys class scsi host host7 Ipfc max luns rw r r 1 root root 4096 Feb 28 17 03 sys class scsi host host7 Ipfc nodev tmo rw r r 1 root root 4096 Feb 28 17 03 sys class scsi host host7 Ipfc scan down r r r 1 root root 4096 Feb 28 17 03 sys class scsi host host7 Ipfc topology rw r r 1 root root 4096 Feb 28 17 03 sys class scsi host host7 Ipfc use adisc Notice that the driver parameters are available as files Reading a file displays the current value of a driver parameter If the permissions allow it you can write a value to the file and it will take effect immediately Driver for Linux Configuration Section Page 14 For example root emulex cat sys class scsi host host7 lpfc log verbose 0 Notice that the current value of lpfc_log_verbose is zero To set it to Oxffff root e
46. f other errors are also occurring please report this message to Technical Support elx_mes0716 FCP read underrun expected lt len gt residual lt resid gt DESCRIPTION An FCP device provided less data than was requested DATA 1 fepi_parm 2 cmnd 0 3 underflow SEVERITY Information LOG LOG_FCP verbose ACTION None required elx_mes0717 FCP command lt cmd gt residual underrun converted to error DESCRIPTION The driver converted this underrun condition to an error based on the underflow field in the SCSI command DATA 1 len 2 resid 3 underflow SEVERITY Information LOG LOG_FCP verbose ACTION None required elx mes0718 Unable to dma map single request buffer lt dma_error gt DESCRIPTION An error occurred while sending a command and the command will be retried DATA none SEVERITY Error LOG Always ACTION If the problem persists please report the error to Technical Support Driver for Linux Troubleshooting Section Page 46 elx mes0719 LUN Reset I O flush failure cnt lt cnt gt DESCRIPTION Timed out while waiting during a LUN reset DATA none SEVERITY Information LOG LOG_FCP verbose ACTION If other errors are also occurring please report this message to Technical Support elx_mes0720 FCP command lt cmnd 0 gt residual overrun error DESCRIPTION A residual overrun error has occurred while processing the specified FCP command DATA 1 request_bufflen 2 resid SEVER
47. g for a node table entry based on the DID and the entry was not found DATA 1 order SEVERITY Information LOG LOG NODE verbose ACTION None required Driver for Linux Troubleshooting Section Page 49 elx mes0933 FIND node DID reglogin DESCRIPTION The driver is searching for a node table entry on the reglogin list based on DID DATA 1 ndlp 2 nlp DID 3 nlp flag 4 data1 SEVERITY Information LOG LOG NODE verbose ACTION No action needed informational elx mes0934 FIND node DID prli DESCRIPTION The driver is searching for a node table entry on the prli list based on DID DATA 1 ndlp 2 nlp DID 3 nlp flag 4 data1 SEVERITY Information LOG LOG NODE verbose ACTION No action needed informational elx mes0935 FIND node DID npr DESCRIPTION The driver is searching for a node table entry on the npr list based on DID DATA 1 ndlp 2 nlp DID 3 nlp flag 4 data1 SEVERITY Information LOG LOG NODE verbose ACTION No action needed informational elx_mes0936 FIND node DID unused DESCRIPTION The driver is searching for a node table entry on the unused list based on DID DATA 1 ndlp 2 nlp DID 3 nlp_flag 4 data1 SEVERITY Information LOG LOG_NODE verbose ACTION No action needed informational Miscellaneous Events 1200 1299 elx_mes1209 C_CT request error DESCRIPTION The CT response returned more data than the user buffer could hold DATA 1 outdmp gt flag
48. hen unmount the drives If you cannot exit all applications that use Fibre Channel attached drives the uninstall will work properly but you must reboot after the uninstallation is complete 3 Stop HBAnyware Type cd usr sbin hbanyware stop hbanyware Uninstall the utilities See page 12 for instructions Copy the Ipfc install script to the temporary directory For example cp usr src lpfc lpfc install tmp 6 Execute the Ipfc install script with the uninstall option Type tmp lpfc install uninstall If the machine is configured to boot from a SAN attached disk through an Emulex HBA one of the following tasks is required depending upon your OS version These steps ensure that your system will boot successfully by creating a new ramdisk image containing the Ipfc driver that originally shipped with the distribution e Fora system with SuSE Linux Enterprise Server without a Service Pack or with Service Pack 1 installed edit the INITRD_MODULES string in the etc sysconfig kernel file to include the Ipfcdd driver For example a string that looks like INITRD MODULES mptscsih jbd ext3 should be modified to look like INITRD MODULES mptscsih jbd ext3 lpfcdd e Fora system with SuSE Linux Enterprise Server Service Pack 2 edit the INITRD MODULES string in the etc sysconfig kernel file to include the Ipfc driver For example a string that looks like INITRD MODULES mptscsih jbd ext3 should be modified to look like
49. ies from the Emulex web site or copy them to the system from the installation CD 3 Copy the ElxLinuxApps lt AppsRev gt lt DriverRev gt tar file to a directory on the install machine Change use cd command to the directory to which you copied the tar file 5 Untar the file Type tar xvf ElxLinuxApps lt AppsRev gt lt DriverRev gt tar 6 Uninstall any previously installed versions Type uninstall Note You must run the uninstall script that shipped with the version of the Application Helper Module you want to remove If the uninstall script resides in the src directory be sure to copy it to a temporary directory before you run it 7 Run the install script Type install 8 Enter the type of management you want to use 1 Local Mode HBA s on this Platform can be managed by HBAnyware clients on this Platform Only 2 Managed Mode HBA s on this Platform can be managed by local or remote HBAnyware clients 3 Remote Mode Same as 2 plus HBAnyware clients on this Platform can manage local and remote HBA s 9 You are prompted as to whether or not to allow users to change management mode after installation Enter the letter y for yes or n for no Driver for Linux Installation Section Page 7 Utilities Directory Structure After installation the following directories are created on the system Table 2 Utilities Directory Structure Directory Description lusr sre lpfedfe Application Helpe
50. ion LOG Always ACTION No action needed informational elx_mes0262 Cannot unblock scsi target DESCRIPTION A SCSI target could not be unblocked DATA none SEVERITY Error LOG Always ACTION Please report this issue to Technical Support Driver for Linux Troubleshooting Section Page 35 elx mes0263 Cannot block scsi target target ptr lt targetp gt DESCRIPTION The SCSI target with the specified target pointer could not be blocked DATA none SEVERITY Error LOG Always ACTION Please report this issue to Technical Support elx_mes0264 HotPlug support enabled DESCRIPTION HotPlug support has been enabled DATA Error SEVERITY Information LOG Always ACTION No action needed informational Mailbox Events 0300 0399 elx_mes0300 READ_LA no buffers DESCRIPTION The driver attempted to issue a READ_LA mailbox command to the HBA but there were no buffers available DATA None SEVERITY Warning LOG LOG MBOX verbose ACTION This message indicates 1 Kernel virtual memory is depleted Check that the system meets minimum RAM requirements for the Emulex Fibre Channel adapter Try closing other applications to free some memory 2 A possible driver buffer management problem If this problem persists report the error to Technical Support elx mes0301 READ SPARAM no buffers DESCRIPTION The driver attempted to issue a READ SPARAM mailbox command to the HBA but there were no buffers availab
51. ith verbose mode on for more details elx_mes0227 Node Authentication timeout DESCRIPTION The driver has lost track of what NPORTs are being authenticated DATA None SEVERITY Error LOG Always ACTION None required The driver should recover from this event elx_mes0228 CLEAR LA timeout DESCRIPTION The driver issued a CLEAR_LA that never completed DATA None SEVERITY Error LOG Always ACTION None required The driver should recover from this event Driver for Linux Troubleshooting Section Page 31 elx mes0229 Cannot assign scsi ID lt nlp_sid gt to NPort lt nlp_DID gt DESCRIPTION The driver cannot assign a scsi id to a discovered mapped FCP target DATA 1 nlp_flag 2 nlp_state 3 nlp_rpi SEVERITY Information LOG LOG_DISCOVERY LOG_FCP verbose ACTION No action needed informational elx_mes0230 Cannot assign scsi ID on NPort lt nlp_DID gt DESCRIPTION The driver cannot assign a scsi id to a discovered mapped FCP target DATA 1 nlp_flag 2 nlp_state 3 nlp_rpi SEVERITY Information LOG LOG_DISCOVERY LOG_FCP verbose ACTION Check persistent binding information elx_mes0231 RSCN timeout DESCRIPTION The driver has lost track of what NPORTs have RSCNs pending DATA 1 fe ns retry 2 Ipfc max ns retry SEVERITY Error LOG Always ACTION None required The driver should recover from this event elx_mes0232 Continue discovery with lt num disc nodes gt PLOGIs to go DESC
52. le DATA None SEVERITY Warning LOG LOG MBOX verbose ACTION This message indicates 1 Kernel virtual memory is depleted Check that the system meets minimum RAM requirements for the Emulex Fibre Channel adapter Try closing other applications to free some memory 2 A possible driver buffer management problem If the problem persists report the error to Technical Support elx mes0302 REG LOGIN no buffers DESCRIPTION The driver attempted to issue a REG LOGIN mailbox command to the HBA but there were no buffers available DATA 1 Did 2 flag SEVERITY Warning LOG LOG MBOX verbose ACTION This message indicates 1 Kernel virtual memory is depleted Check that the system meets minimum RAM requirements for the Emulex Fibre Channel adapter Try closing other applications to free some memory 2 A possible driver buffer management problem If the problem persists report the error to Technical Support Driver for Linux Troubleshooting Section Page 36 elx mes0304 Stray mailbox interrupt moxCommand lt mbxcommand gt mbxStatus lt mbxstatus gt DESCRIPTION Received a mailbox completion interrupt and there are no outstanding mailbox commands DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0305 Mbox cmd cmpl error RETRYing DESCRIPTION A mailbox command completed with an error sta
53. masks for the specified ring DATA None SEVERITY Warning LOG LOG_SLI verbose ACTION This error could indicate a software driver firmware or hardware problem Report these errors to Technical Support elx_mes0315 Ring lt ringno gt issue portCmdGet lt local_getidx gt is bigger then cmd ring lt max_cmd_idx gt DESCRIPTION The port cmd ring get index is greater than the size of cmd ring DATA None SEVERITY Error LOG Always ACTION This error could indicate a software driver firmware or hardware problem Report these errors to Technical Support elx_mes0316 Cmd ring lt ringno gt put iotag lt iotag gt greater then configured max lt fast_iotag gt wd0 lt icmd gt DESCRIPTION The assigned I O iotag is greater than the allowed maximum DATA None SEVERITY Error LOG Always ACTION This error could indicate a software driver firmware or hardware problem Report these errors to Technical Support Driver for Linux Troubleshooting Section Page 38 elx mes0317 Rsp ring lt ringno gt get iotag lt iotag gt greater then configured max lt fast iotag gt wd0 lt irsp gt DESCRIPTION The assigned I O iotag is greater than the maximum allowed DATA None SEVERITY Error LOG Always ACTION This error could indicate a software driver firmware or hardware problem Report these errors to Technical Support elx_mes0318 Outstanding I O count for ring lt ringno gt is at max lt fast_iotag gt DESC
54. matching command for the completion received on the specified ring DATA 1 ulpStatus 2 ulpWord 4 3 ulpCommand 4 ulpContext SEVERITY Warning LOG LOG_SLI verbose ACTION This error could indicate a software driver or firmware problem If problems persist report these errors to Technical Support Driver for Linux Troubleshooting Section Page 39 elx mes0323 Unknown Mailbox command lt mbxCommand gt Cmpl DESCRIPTION A unknown mailbox command completed DATA None SEVERITY Error LOG Always ACTION This error could indicate a software driver firmware or hardware problem Report these errors to Technical Support elx_mes0324 Config port initialization error moxCmd lt mbxCommand gt READ_NVPARM mbxStatus lt mbxStatus gt DESCRIPTION A read nvparams mailbox command failed during port configuration DATA None SEVERITY Error LOG Always ACTION This error could indicate a software driver firmware or hardware problem Report these errors to Technical Support elx_mes0325 Reset HBA DESCRIPTION An HBA has been reset DATA 1 hba_state 2 sli_flag SEVERITY Information LOG LOG_SLI verbose ACTION No action needed informational elx_mes0326 Rsp Ring lt ringno gt error IOCB DESCRIPTION An IOCB error has occurred on the specified ring DATA 1 ulpWord 0 2 ulpWord 1 3 ulpWord 2 4 ulpWord 3 5 ulpWord 4 6 ulpWord 5 7 irsp 6 8 irsp 7 SEVERITY Warning LOG LOG_SLI ver
55. modprobe and etc modprobe conf The following sections describe how to set driver parameters using the modprobe command and by manually editing etc modprobe conf Note Emulex recommends using the HBAnyware utility or the hbacmd to change parameters See the HBAnyware User Manual for more information Temporary Configuration Method When you manually load the driver as a module using the modprobe command and change one or more driver parameter values it is a temporary configuration These changes are considered temporary because they are valid for the current session only or until the driver is manually loaded again Using the insmod command requires no editing or saving This temporary configuration method overrides the modprobe conf file for the current session Values can be expressed in hexadecimal or decimal notation Example of Temporary Configuration You want to temporarily set lun_queue_depth to 20 default is 30 for all host bus adapters in your system Load the driver with the following command modprobe lpfc lpfc_lun queue depth 20 Note You cannot override parameters set in modprobe conf Driver for Linux Configuration Section Page 13 Persistent Configuration Method To make the driver parameters persistent across module loads and reboots modify the etc modprobe conf file If driver parameters are modified in etc modprobe conf the driver must be reloaded for the parameters to take effect Also a new ram
56. mulex echo Oxffff gt sys class scsi host host7 lpfc_log verbose root emulex cat sys class scsi host host7 lpfc log verbose Oxf f f Creating a New Ramdisk Image The Ipfc install script creates a ramdisk containing the Ipfc driver for the currently running kernel on systems running Red Hat Enterprise Linux or SuSE Linux Enterprise Server Note You must perform this step whenever the Ipfc options in etc modprobe conf are changed and you want the change to take affect on the next reboot For Installed Ipfc Driver Kits To create a new initial ramdisk image su to root 2 Type cd usr src lpfc 3 Execute the Ipfc install script using the createramdisk option Type lpfc install createramdisk For Distribution In Box Ipfc Drivers To create a new initial ramdisk image e For RHEL4 distributions type mkinitrd allow missing f boot initrd uname r img uname r e For SLES9 PPC64 architecture distributions type mkinitrd k vmlinux i initrd e For SLES9 non PPC64 architecture distributions type mkinitrd k vmlinuz i initrd Dynamically Adding LUNs and Targets The Emulex driver for Linux enables you to dynamically add LUNs and targets without unloading or reloading the Ipfc module and without resetting the adapter To rescan an HBA s targets with sysfs given the HBA s host number in this example 3 type echo gt sys class scsi_host host3 scan Driver for Lin
57. n the install script Type wsinstall 4 When prompted enter the Web server s document root directory For example srv www htdocs Driver for Linux Installation Section Page 8 5 You are provided with the IP address of the host and asked if that is the IP address that is being used by your Web server Answer Y or N as appropriate If you answer N you are prompted for the IP address you wish to use 6 You are asked if your web server listening on the normal default HTTP port 80 Answer Y or N as appropriate If you answer N you are prompted for the port you wish to use You are notified the installation of the HBAnyware Web Launch package has completed Installing the HBAnyware Security Configurator Follow these instructions to install the HBAnyware Security Configurator on your system The install script is located in usr sbin hbanyware directory Prerequisites The Ipfc driver must be installed e Previous versions of the Application Helper Module must be uninstalled e HBAnyware must be installed on all participating systems Procedure To install the HBAnyware Security Configurator utility Log on as root 2 Change use the cd command to the directory to which you copied the tar file See Installing the Utilities and the Application Helper Module on page 7 step 2 for reference 3 Run the install script with the ssc parameter specified Type install ssc Installing HBAnyware and the
58. nitiator mode e Supports up to thirty two host bus adapter HBA ports Supports the latest HBAnyware configuration utility version 3 3 as part of master kit enabling GUl based driver configuration and persistent binding management including inband FC and out of band TCP IP remote SAN management capability diagnostics loopback and diagnostics dump e Supports Common HBA API e Batch firmware download capability e Supports the sysfs interface e PCI hot plug support e Vital Product Data VPD support e The Linux Tools link on the Linux portion of the Emulex Web site visit the link to see the available tools New Features in this Release The Emulex version 8 0 16 34 driver for Linux includes the following enhancements e Supports the latest HBAnyware configuration utility version 3 3 as part of master kit Refer to the HBAnyware 3 3 User Manual for more information Driver for Linux Installation Section Page 1 Prerequisites For the Ipfc Driver Kit To install the Ipfc driver kit the appropriate distribution kernel development packages must be installed for the currently running kernel which include the gcc compiler and the kernel sources The Ipfc driver kit supports the following distributions SuSE Linux Enterprise Server 9 Service Pack 2 or later Intel x86 Intel Itanium2 Intel EM64T AMD64 and PowerPC 64 bit architectures Red Hat Enterprise Linux 4 update 3 or later updates Intel x86 Intel Itani
59. nup node for NPort lt nlp DID gt DESCRIPTION The driver node table entry for a remote NPort was removed DATA 1 nlp flag 2 nlp state 3 nlp_rpi SEVERITY Information LOG LOG NODE verbose ACTION None required elx mes0901 FIND node DID mapped DESCRIPTION The driver is searching for a node table entry on the mapped node list based on the DID DATA 1 ndlp 2 nlp DID 3 nlp flag 4 data1 SEVERITY Information LOG LOG NODE verbose ACTION None required elx mes0902 FIND node DID mapped DESCRIPTION The driver is searching for a node table entry on the mapped node list based on DID DATA 1 ndlp 2 nlp DID 3 nlp_flag 4 data1 SEVERITY Information LOG LOG_NODE verbose ACTION None required elx_mes0903 Add scsiid lt sid gt to BIND list DESCRIPTION The driver is putting the node table entry on the binding list DATA 1 bind_cnt 2 nlp_DID 3 bind type 4 blp SEVERITY Information LOG LOG_NODE verbose ACTION None required elx_mes0904 Add NPort lt did gt to lt list gt list DESCRIPTION The driver is putting the node table entry on the specified list DATA 1 nlp_flag 2 blp SEVERITY Information LOG LOG_NODE verbose ACTION None required elx_mes0908 FIND node DID plogi DESCRIPTION The driver is searching for a node table entry on the plogi list based on DID DATA 1 ndlp 2 nlp DID 3 nlp_flag 4 data1 SEVERITY Information LOG LOG_NODE verbose ACTI
60. ose ACTION No action needed informational Driver for Linux Troubleshooting Section Page 23 elx mes0106 ELS cmd tag lt ulploTag gt completes DESCRIPTION The specific ELS command was completed by the firmware DATA 1 ulpStatus 2 ulpWord 4 SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0107 Retry ELS command lt elsCmd gt to remote NPORT lt did gt DESCRIPTION The driver is retrying the specific ELS command DATA 1 retry 2 delay SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0108 No retry ELS command lt elsCmd gt to remote NPORT lt did gt DESCRIPTION The driver decided not to retry the specific ELS command that failed DATA 1 retry 2 nlp_flag SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0109 ACC to LOGO completes to NPort lt nlp_DID gt DESCRIPTION The driver received a LOGO from a remote NPort and successfully issued an ACC response DATA 1 nlp_flag 2 nlp_state 3 nlp_rpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0110 ELS response tag lt ulploTag gt completes DESCRIPTION The specific ELS response was completed by the firmware DATA 1 ulpStatus 2 ulpWord 4 3 nlp_DID 4 nlp_flag 5 nlp_state 6 nlp rpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed
61. oups require a single block of 100 message numbers however some groups INIT FCP require two blocks The groups and the associated number ranges are defined in the Message Log table below The preamble string shown in the Message Log table is displayed as part of the log message The lower case x of the preamble string defines the severity of the log message The x will be replaced by one of five lower case letters Those letters are defined in the Severity Code table Severity Codes Information and warning messages can be turned ON or OFF by setting resetting the appropriate mask bit s in the variable pfc log verbose located in the driver configuration module Ipfc conf c By default both information and warning messages are disabled Configuration error c error e and panic p messages can not be disabled Table 6 Severity Code Table Code Severity i Information w Warning c Configuration Error e Error p Panic Message Group Masks Table 7 defines the log message groups and the associated number ranges The preamble string shown in this table is displayed as part of the log message The lower case x of the preamble string defines the severity of the log message and represents one of five lower case letters defined in the severity codes table Table 7 Message Log Table LOG Message Preamble Ag Verbose Mask String From To Verbose Verbose Description A Bit D
62. r Module source files usr sbin hbanyware HBAnyware files Installing the HBAnyware Utility with Web Launch Prerequisites Before installing the HBAnyware utility with Web Launch ensure your systems meet the following requirements See page 13 for more information about the HBAnyware utility with Web Launch The system on which you are installing the Web Launch services package the server requires the following The HTTP server must be configured to handle the JNLP MIME file type The following MIME file type file extension must be added to your server configuration MIME type application x java jnlp file File Extension jnlp e The HTTP server must be configured and running e The system on which you are running the browser the client requires the following The Java Runtime Environment JRE 5 0 or later must be installed Below are the spe cific requirements e Sun 32 bit JRE 5 0 or later for Intel based systems x86 and IA64 e IBM 64 bit JRE 5 0 or later for PowerPC e Sun 32 bit JRE 5 0 or later x86 64 Refer to the appropriate vendor documentation for detailed instructions about configuring MIME types configuring and starting the HTTP server and installing the JRE e The HBAnyware utility must be installed before installing HBAnyware with Web Launch Procedure To install HBAnyware with Web Launch Logon as root 2 Navigate to the HBAnyware directory Type cd usr sbin hbanyware 3 Ru
63. r kit lt driver version gt tar gz Change to the directory that is extracted cd lpfc 2 6 driver kit lt driver version gt Driver for Linux Installation Section Page 4 6 Execute the Ipfc install script with no options to install the new driver kit Type lpfc install Once the Ipfc install script has completed successfully the Emulex Ipfc driver is loaded and Fibre Channel disks that are properly connected to the system are accessible Reboot the sys tem now to enable the newly added driver options in the ramdisk You can also reboot the sys tem later if you wish Driver Kit Install Script Options The following options are available for use with the Emulex install script for Linux e createramdisk Creates a new ramdisk image Use this option after you have rebuilt the driver This is done by default during installation h help Prints a help message describing command line parameters e u uninstall Uninstalls the currently installed driver kit Driver Kit Directory Structure After installation the following directory is created on the system Table 1 Driver Kit Directory Structure Directory Description usr sre lpfe Driver source files Installing the Driver on Unsupported Linux Distributions The driver kit supports the Linux distributions listed on page 2 As of Linux kernel 2 6 12 the Ipfc driver is distributed with the Linux kernel sources To install the Emulex Ipf
64. scsi host DESCRIPTION Rescanning a SCSI host because a new target has been found DATA none SEVERITY Error LOG Always ACTION No action needed informational elx mes0253 Illegal State Transition node lt nlp_DID gt event lt evt gt state lt nlp_state gt DESCRIPTION An unexpected response was received from the specified node DATA 1 nlp_rpi 2 nlp flag SEVERITY Error LOG Always ACTION Check connection to fabric and or remove device If problem persists please report the issue to Technical Support elx_mes0258 Unblocking IO to Target scsi id lt scsi_id gt NPort pointer lt pnode gt DESCRIPTION The driver has unblocked IO to the specified SCSI ID on the specified NPort DATA none SEVERITY Information LOG LOG_DISCOVERY LOG_FCP verbose ACTION No action needed informational elx_mes0259 Blocking IO to Target scsi id lt scsi_id gt NPort pointer lt pnode gt DESCRIPTION The driver has blocked IO to the specified SCSI ID on the specified NPort DATA none SEVERITY Information LOG LOG_DISCOVERY LOG_FCP verbose ACTION No action needed informational elx_mes0260 Remove Target scsi id lt scsi_id gt DESCRIPTION The specified SCSI ID has been removed DATA Error SEVERITY Information LOG Always ACTION No action needed informational elx_mes0261 Adding Target scsi id lt scsi_id gt DESCRIPTION The specified SCSI ID has been added DATA Error SEVERITY Informat
65. se data DATA 1 retry 2 resid SEVERITY Information LOG LOG_FCP verbose ACTION None required elx mes0711 detected queue full lun queue depth adjusted to d DESCRIPTION The driver detected a queue full status on a scsi command response New lun queue depth is reported DATA 1 New lun queue depth SEVERITY Warning LOG LOG_FCP verbose ACTION This may indicate an oversubscribed target array Check your SAN configuration and IO workload Driver for Linux Troubleshooting Section Page 45 elx mes0712 Bus Reset on Target lt tgt gt Failed DESCRIPTION A bus reset on the specified target failed DATA None SEVERITY Information LOG LOG FCP verbose ACTION Check the state of the device in question elx_mes0713 SCSI layer issued LUN reset lt target gt lt LUN gt DESCRIPTION The SCSI layer is requesting the driver to abort I O to a specific LUN DATA 1 ret 2 status 3 result SEVERITY Error LOG Always ACTION Check the state of the target in question elx_mes0714 SCSI layer issued bus reset DESCRIPTION The SCSI layer is requesting the driver to abort all I Os to all targets on this HBA DATA 1 ret SEVERITY Error LOG Always ACTION Check the state of the targets in question elx_mes0715 Bus Reset I O flush failure cnt lt cnt gt left lt index gt DESCRIPTION Timed out while waiting during a bus reset DATA none SEVERITY Information LOG LOG_FCP verbose ACTION I
66. tus lt mbxStatus gt DESCRIPTION Adapter initialization failed when issuing an INIT_LINK mailbox command DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0455 Vital Product DESCRIPTION Vital product data VPD contained in the HBA flash DATA 1 vpd 0 2 vpd 1 3 vpd 2 4 vpd 3 SEVERITY Information LOG LOG_INIT verbose ACTION No action needed informational elx_mes0457 Adapter Hardware Error DESCRIPTION The driver received an interrupt indicting a possible hardware problem Data 1 status 2 status1 3 status2 SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0458 Bring adapter online DESCRIPTION The FC driver has received a request to bring the adapter online DATA None SEVERITY Warning LOG LOG_INIT verbose ACTION None required elx_mes0460 Bring adapter offline DESCRIPTION The FC driver has received a request to bring the adapter offline DATA None SEVERITY Warning LOG LOG_INIT verbose ACTION None required elx_mes0462 Too many cmd rsp ring entries in SLI2 SLIM DESCRIPTION The configuration parameter for Scan down is out of range Driver for Linux Troubleshooting Section Page 44 DATA 1 totiocb 2 MAX SLI2 IOCB S
67. tus that causes the driver to reissue the mailbox command DATA 1 mbxCommand 2 mbxStatus 3 un varWords 0 4 hba_state SEVERITY Information LOG LOG MBOX verbose LOG SLI verbose ACTION No action needed informational elx_mes0306 CONFIG_LINK mbxStatus error lt mbxStatus gt HBA state lt hba_state gt DESCRIPTION The driver issued a CONFIG_LINK mbox command to the HBA that failed DATA None SEVERITY Error LOG Always ACTION This error could indicate a firmware or hardware problem Report these errors to Technical Support elx_mes0307 Mailbox cmd lt mbxCommand gt Cmpl lt mbox_cmpl gt DESCRIPTION A mailbox command completed DATA 1 pmbox 2 varWords 0 3 varWords 1 4 varWords 2 5 varWords 3 6 varWords 4 7 varWords 5 8 varWords 6 9 varWords 7 SEVERITY Information LOG LOG MBOX verbose LOG SLI verbose ACTION No action needed informational elx_mes0308 Mbox cmd issue BUSY DESCRIPTION The driver attempted to issue a mailbox command while the mailbox was busy processing the previous command The processing of the new command will be deferred until the mailbox becomes available DATA 1 mbxCommand 2 hba_state 3 sli_flag 4 flag SEVERITY Information LOG LOG MBOX verbose LOG SLI verbose ACTION No action needed informational elx_mes0309 Mailbox cmd lt mbxcommand gt issue DESCRIPTION The driver is in the process of issuing a mailbox command DATA
68. um2 Intel EM64T AMD64 and PowerPC 64 bit architectures Compatibility LPe11000 LPe11002 and LPe1150 minimum firmware version 2 50a4 Firmware version 2 72a2 is recommended for best performance LP11000 LP 11002 and LP1150 minimum firmware version 2 10a7 Firmware version 2 72a2 is recommended for best performance LP1005DC CM2 minimum firmware version 1 90a5 LP10000ExDC and LP1050Ex minimum firmware version 1 91a1 LP10000DC and LP10000 minimum firmware version 1 91a1 LP1050DC and LP1050 minimum firmware version 1 91a1 LP9802DC minimum firmware version 1 91a1 LP9802 minimum firmware version 1 91a1 LP982 minimum firmware version 1 91a1 LP9402DC LP9002DC LP9002L and LP9000 minimum firmware version 3 93a0 LP952L minimum firmware version 3 93a0 LP8000 and LP8000DC e If your HBA has a Dragonfly chip version 2 00 or greater use firmware version 3 93a0 e If your HBA has a Dragonfly chip below version 2 00 use firmware version 3 30a7 Refer to the LP8000 and LP8000DC Firmware Download page on the Emulex Web site to deter mine the Dragonfly chip version in use Things to Know Before You Download You must uninstall any previous Ipfc driver kits and or Application Helper Modules that were installed from the Emulex CD or downloaded from the Emulex Web site i e not part of a distribution before installing this driver kit You must be running RHEL 4 4 kernel 2 6 9 42 EL or above to use the diskdump f
69. uninstall script that shipped with the version of HBAnyware and the Application Helper Module you want to remove If the uninstall script resides in the usr src directory be sure to copy it to a temporary directory before you run it To uninstall HBAnyware and the Application Helper Module 1 Logon as root 2 Change use cd command to the directory to which you copied the tar file during installation 3 Uninstall any previously installed versions Type uninstall Driver for Linux Installation Section Page 12 Configuration You can configure the driver by Setting module parameters using modprobe and etc modprobe conf Using the sysfs interface for parameters which can be changed after loading the driver e Editing the driver properties in the Ipfc conf file See the Driver Parameters Reference Table on page 16 to view the list of configurable driver properties e Using the HBAnyware configuration utility See the HBAnyware 3 3 User Manual for more information Note Driver parameter changes made using modprobe conf or the HBAnyware utility persist if the driver is uninstalled To return to the default settings you must modify the settings in modprobe conf Note The Linux 2 6 kernel only supports setting the log verbose nodev tmo and use adisk driver parameters for individual HBAs You must apply other driver parameters to all HBAs contained in the host Driver Configuration Methods Using
70. utomatically archives any driver that is shipped as part of the distribution s kernel during the installation procedure Old drivers that are archived during installation are then restored when the driver kit is uninstalled Note The HBAnyware configuration utility and the Application Helper Module are bundled together and must be installed separately from the driver Refer to the Installing the Utilities on page 12 for more information Note The Ipfc install script does not support custom kernels For example kernels with Version_Release strings that do not match those of the original distribution kernel To install the Emulex driver for Linux 1 Install a supported Emulex HBA in the system Refer to the HBA s Installation manual for specific hardware installation instructions Remove any previously installed Ipfc driver kits and or Application Helper Modules that were installed from the Emulex CD or downloaded from the Emulex Web site i e not part of a distribution s kernel before proceeding Refer to Uninstalling the Driver Kit on page 10 Uninstalling a Previous Application Helper Module Stand Alone Kit on page 11 and Uninstalling the Utilities on page 12 for more information Download the driver kit from the Emulex web site or copy it to the system from the installation CD Log on as root to a terminal and unpack the tarball with the following command tar xzf lpfc_2 6 drive
71. ux Configuration Section Page 15 To limit the rescan to a particular target given the HBA s host number in this example 3 and the target number in this example 2 type echo 2 gt sys class scsi host host3 scan You can also use the Emulex lun scan script in usr sbin Ipfc Changing Non dynamic Parameter Values To change non dynamic parameter values 1 Navigate to the usr sbin hbanyware directory and run the scripts to stop the HBAnyware utility processes Type stop hbanyware Stop all I O to Ipfc attached devices Unload the Ipfcdfc driver Type rmmod lpfcdfc 4 Unload the Ipfc driver Type rmmod lpfc 5 Reload the driver Type modprobe lpfc modprobe lpfcdfc The HBAnyware utility services will start automatically when you launch the application For these changes to persist after a reboot you must create a new ramdisk image See Creating a New Ramdisk Image on page 15 to learn how Driver Parameters Reference Table The driver parameters determine some aspects of the driver behavior The following tables list the driver parameters Some driver parameters can be modified and take effect only on a driver load while others can be modified dynamically and take effect immediately The tables also list the default minimum and maximum values for these parameters To change driver properties Open the Ipfc conf file in a text editor Change the properties you wish Save the file Sun If require
72. y for its use nor for any infringements of patents or other rights of third parties that may result Periodic changes are made to information contained herein although these changes will be incorporated into new editions of this manual Emulex Corporation disclaims any undertaking to give notice of such changes Driver for Linux User Manual Page ii TE TE sacesiinecenascashannadecsassssnascsnncaeacdauanawenadveusceesauauanaweanadsssndeeseiseanawenes 1 Driver INfOFMATOM ssicccccsctaseccnataeatatetetetetedetetatanatatetatatadatedatecatanatanetatenatatedenatetacatadenac 1 Supported Features ccccccccceeceeeeccceeeee eee eeeeeeccaaeeeeeeeeceegcaaaeeeeeeeeedaeeeeeeeeennee 1 New Features in this RelGaSe ccccccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 1 Prerequisites 2 0 eee eee eee ll ll nnnnnnnnnnnnnnnnnnnnnnnnnnnnunnnnnannnnnnnnnunnnunununnnnnunnn 2 For the Ipfe Driver Kit ccccecccccceeeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 2 Go 191 0 10 01 h EEE NN 2 Things to Know Before You Download aaa 2 KNOWN ISSUCS Li nnennnem ma 3 Installing the Driver Kit cceeceesccececceceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 4 Driver Kit Install Script Options rreennnonnnnnrrrnnnnnnnrrnnnnrrrnnnnnnnrrrnnnrrrnnnnnensrrnnnnnn 5 Driver Kit Directory Structure rreravrrrnnnrrrrnvnvvnnrnnnnrrrnnnnnnnnrnnnnnrrnnneennnrnnnnnrnnnnne 5 Installing