Home

MOBILE CALL GSM Alarm System

image

Contents

1. Auto dial NSN Alarm System K MOBILE CALL GSM Alarm System For a better understanding of this product please read this user manual thoroughly before using it uto dia IW panto Ae ERa A NA CONTENTS l Function Instruction 0seeeeeesenssenssesseessseessesssesseesssessersseeesee 1 Il Alarm Host Diagram ss pnenssrasendacencaiaatnnernneannrmmiemonnieienaneimienwen 2 Alarm Panel front schematic GiaQram cscccccseeecceeeceeseseceeees 2 BD AS AW so se cena da E AAT 2 Alarm Panel back schematic GiaQram ccsecsscccesecssceeeeeeeeeneees 3 Wired terminal DIOCK cccccscescceseccesceeeccesscesecseecscesecessceeces 3 IN DOOPF SONS OF 6 cdssssssscscusesssenesanntearisenssedsvorntasssesesdeesseusteonesesiebvenrenie 4 IV Wireless PIR detector c ccc ccccccsecccseeeeseceeeeeeeseeaeceaeeees 5 V Function Settings 0 0 0 0 cccccceseccccceesseeccceeeeececeeaeseeccesaneeseeees 5 C MNAZaUO N eses nai EEI E 5 2L EMO oG UNIS eei EE EA 5 SA Exit Settings recoin eee eee ene ene ree 6 Ay AF CNR ROS Erie saossacoteacee E E 6 5 Coding OF Remote COMI Olle i ic icccsscynesseiarpacctaxeascessvasyracksenperderecnevss 6 6 Delete Remote Controller cc ceccccccesssseecccesseccceceeeescceseeasees T 7 COdING of Defense ZONE yncocssccceoawieciexsedereaciaanscaveiessGacaeisnessiesnsderees T 8 Delete Defense ZONE cccccccsssccccsseccceessccc
2. 3 Exit Settings Press and buttons the main unit emits a long beep and exits settings The SET indicator goes out and the system returns to disarm state Operating method gt 4 Factory Reset In disarm status use keypad to input 95175308246 and press to confirm all the LED indicators will be on for 2 seconds and you will hear a long beep The main unit gets all its settings cleared and restores to its factory settings successfully Operating method 95175308246 5 Coding of Remote Controller Extra remote controller has to be code to the alarm host in order to perform normally The one in the standard package has been coded In setup state use keypad to input 20 input the remote controller number 1 8 and then press to confirm The main unit emits a long beep and you will hear remote control coding The indicator is on without flashing press any button on the wireless remote controller the main unit makes a long beep and you will hear coding completed indicator goes out indicating the remote controller succeeds in coding Functions Settings Operating method 20 gt A gt A indicates 1 8 remote controllers number You can add maximum 8 remote controllers LCD display gt Heeg i 6 Delete Remote Controller The remote controller can t control the main unit after it s deleted In setup st
3. Technical Parameters List 1 Input Voltage DC12V 1A Alarming Current lt 450mA Wireless Frequency 315 433MHz PT2262 EV1527 4 7MQ GSM Frequency 850 900 1800 1900MHz Back up Battery LI DC7 4V Siren Volume 110dB CC Way 4 Care and Maintenance List 2 pee e ee e invalid Door alarm alarm Te e Zonee 6 effective effective realtime time Gasalarm alarm Emergency effective effective real time Emergency button alarm Zones 6 effective effective realtime time Gasalarm Gasalarm alarm me Nee ened invalid real time Emergency zone 94 99 alain Program Password eas Remote control Components List Main panel TDC Remote controller 2 pcs Siren 1 pc PIR sensor 1 pc Door sensor 1 pc Power adapter 1 pc User manual 1 pc Care and Maintenance ser A en ID lcs ee gp ea a AA year BB month CC date oa ange ea System Time Setting op hour EE minute FF second 33 35 AA 3 groups of auto arm time BB nine en AA hour BB minute 36 38 AA 3 groups of auto disarm time BB Timey Disarm AA hour BB minute Timing Control turn 39 0 1 on off the function of timely arm disarm Wireless a Transmission Control OEE IAUN Wireless Siren i D4 y 01 99 Coding Encryption Siren coding number 01 99 44 01 I 2 Lies fae ne Default 6 0seconds 45 01 99
4. 27 Voice Prompt for All SettingS ceesseecccessescceceeeeeeeeeees 17 20 NA CS CIM Oe scters neces nesncdcnnvretsneatneudcssa e E LESNE 18 Vi Operation INStructions cece csecccsscceeeeceeeeeceeeeeees 18 1 System status There are 4 status as following 006 18 2 Remote Controller Operation cccccecccseecescceeeeceeceeeceeeees 18 STIOMC Alesanana rina NENEN 18 OUA e e E T E E EE 19 SD E a EE E E AAEE E AA AE A A E E 19 6 Answer Alarm Call ccccccccsssccccesesecccceeescceeeescccseeeeeceeseeeseees 20 T ROMO CONTO eriei N E E T 21 MOTOS ICO ccscnnsaesaprecentecisipisineraraiaaarainaitentecarwaucnnntes 21 9 System Dialing FUNCTION cccccessscceeeessecenceeeeeesscescesees 21 10 Alarming Record Che ckinng cccsccesccceeessecescceeeeasscesees 21 1LGOGSM Signal CHECKING vaicicuicticcacscreiesateeerurctssaandenipsarecencieestidoass 22 Vil Technical Parameters ccccccccceecssecesceeeeeeseeeeeneees 23 VIII Components LiSt cece ccceceseecceeeeeseceesaeeeeeeeeeeees 24 IVV Care and Maintenance ccccccceecce eee seeceeceeeeeeeeees 27 Features Function Instruction x x Ww la a5 au X X lt lt go GE GE 6 wired and 99 wireless defense zones LCD screen with time clock display Voice prompt for all operations 3 groups of timely arm and disarm Can store 6 phone numbers when
5. Alarm Delay Time Setting Default no delay Melt enone Alarm Number 6 groups of alarming user number number Setting ere g Care and Maintenance 51 56 number S7 59 60 AA B C D 61 01 12 0 1 57 59 Phone SMS Receiving Number Setting 3 groups of SMS receiving number Delete SMS Receiving Number Defense Zone Programming Home Arm Defense Zone Setting AA Defense zone number 01 99 B Defense zone type 1 real time 2 40 seconds delay 3 24 hours 4 bypass C Defense zone location 1 SOS Alarm 2 Fire Alarm 3 Gas Leak Alarm 4 Door Alarm 5 Hall Alarm 6 Window Alarm 7 Balcony Alarm 8 Boundary Alarm D Siren ON OFF 0 OFF 1 ON Defense zone number 01 12 0 Home arm but not alarm 1 Home arm and alarm 75 0 1 0 off default 1 on mem fee Voice P tf 84 01 A Settings 0 off 1 on default 0 Alarming Record Checking Press 2 upturn Press 8 downturn Press Exit Care and Maintenance Dial telephone System Dialing number Function sor oil Factory Reset Use with caution operation password ey SMS Default operation password 1234 operation password 2 Disarm by SMS Default operation password 1234 operation Alarm Record password 3 Checking by SMS Default operation password 1234 N
6. Emergency Help mode 1 siren on in Emergency Help mode System default 0 siren off 26 Arm Disarm Voice Prompt This product has this function when you arm disarm it it will give voice prompt system armed disarmed You can deactivate it if you do not need In setting status first input 83 then 0 1 and finally press to confirm voice prompts setting completed please enter instruction Operating method 83 gt A gt A indicates 1 activate voice prompt for arm disarm factory default 0 deactivate voice prompt for arm disarm 27 Voice Prompt for All Settings For above settings you could hear the voice prompt such as setting completed please enter instruction delete completed You can deactivate the voice if you do not need them In setting status first input 84 then 0 1 and finally press to confirm voice prompts setting completed please enter instruction Operating method 84 gt A gt A indicates 1 activate voice prompt for arm disarm factory default 0 deactivate voice prompt for arm disarm Note after you deactivate this function all the voice including arm disarm voice would not work CC Way 4 Operating Instructions 28 IMEI Checking In setting status first input 88 and then press to confirm The 15 digit IMEI code will be displayed on the screen It will display 4 digits each time Operation Instructions 1
7. Power Indicator CallOut 2 222 228 Ojo Out Arm cmenueny r a Home Arm Speaker _ z e Mic LCD display E XO EBBY panang Fire Alarm Gas Laka Window Alarm Door Alarm A SOS Hall Alarm Balcony Alarm Boundary Alarm Iai Installation Installation Alarm Panel back schematic diagram Put SIM card in this card slot Plug in siren connector SIM Slot Connect to the extemal power supply Ss 4 Switch Switch for backup battery Tum it on after power on Note 1 LB and LB are to connect external speaker If you think the internal speaker is not loud enough please contact us for professional speakers 2 Connect one cable of the wired sensor to GND and the other to Z1 Z2 Z3 1Z0 3 Please pay attention to the siren connection Do not mix the two cables together when connecting Otherwise it will ired terminal block damage the transistor in the main panel LBs LB 12V GNO Z 22 Z3 24 Z5 26 Battery Slot Door sensor Door sensors are used for detecting the status of open and close of windows and doors It will detect it and send the signal to main panel z E OW FOL OCTONS OPOrOY x Tear apart the double side adhesive tape on the magnet LB LB 12V GND Z1 Z2 Z3 Z4 Z5 Z 12V Output Port et x and the transmitter Then Siren Port Negative Wired Zone 1 6 Sir
8. real time defense zone 2 40 seconds delay defense zone 3 24 hours defense zone 4 bypass defense zone C alarm type 1 SOS Alarm 2 Fire Alarm 3 Gas Leak Alarm 4 Door Alarm 5 Hall Alarm 6 Window Alarm 7 Balcony Alarm 8 Boundary Alarm After setting the alarm type the corresponding alarm type icon will be shown on the LCD screen when alarming And you will hear the alarm type voice prompt when answering the alarm call D siren ON OFF 0 OFF 1 ON For example set defense zone 12 to be 24 hour fire alarm and siren on Operating method 60 12 3 2 1 i 22 Home Arm Defense Zone Setting Home arm defense sometimes for example when you are at home you want some of the sensors work while some do not you can do this setting In setup state use keypad to input 61 then choose the corresponding defense zone number 01 99 then choose Home Arm and then choose whether alarm 0 1 button and finally press to confirm The main unit will make a long beep and a voice prompt setting completed Operating method 61 XX A f XX indicates 01 99 is defense zone 1 to defense zone 99 A indicates 0 no alarm under home arm status even the sensor is triggered 1 alarm under home arm status Example set sensor in defense zone 10 make alarm under home arm status Functions Settings Operation 61 gt 10 gt 1 gt After this setting when you home arm the system sensor in d
9. as the first voice call number Operating method 51 gt gt 13811111111 gt gt LCD display a 3 SHAR C J 17 Delete Phone Number In setup state input 51 56 and then press to confirm the main unit will make a long beep and the Signal indicator will flicker once and you will hear delete completed which indicate the alarming user number is deleted successfully Operating method XX gt XX indicates the 1 6 alarming user number 51 56 For example Delete the third alarming user number from the system Operating method 53 c gt LCD display z 7 a S ee 18 SMS Receiving Number Setting SMS Receiving number means when system is alarming it will only send SMS to this mobile number You can set maximum 3 SMS numbers In setup state input 57 59 then input the SMS receiving number and then press button to confirm The main unit will make a beep the Signal indicator will flicker once and you will hear setting completed which indicate setup successfully Operating method XX YY YY WC Wan 4 Functions Settings XX indicates address codes of message receiving numbers from the first group to the third group 57 59 YY YY indicates the SMS receiving number For example setup 13822222222 as the first SMS receiving number Operating method 57 gt 138222222 gt 19 Delete SMS Receiving Number
10. completed Operating method 43 gt A gt A indicates the code number 01 99 For example set the wireless coding number as 10 Operating method 43 gt 10 gt LCD display 5 SS 3 aza C E 14 Time Setting of Out Arm Delay Default 60 sec In setup state input the command 44 XX XX indicates the delay time of out arm XX 01 99 1 sec to 99 sec Note The setting is effective only with the panel keyboard operation The operation by remote controller or SMS is immediate arm without delay 15 Time Setting of Alarm Delay Default 40 sec In setup state input the command 45 XX XX indicates the delay time of alarm XX 01 99 1 sec to 99 sec Note The setting is effective only when a zone is set as Alarm Delay Zone Note Before the system enters arm or alarm status it will emit a Di sound per second 16 Alarm Number Setting In setup state input 51 56 then input the voice alarm receiving number mobile number or telephone number and then press to confirm The main unit will make a long beep the Signal indicator will flicker once and you will hear setting completed which indicate voice alarm receiving number is set successfully Functions Settings Operating method XX gt YY YY gt XX indicates the 1 6 alarming user number 51 56 YY YY indicates voice alarm receiving phone number For example set 13811111111
11. system can alarm normally 2 Check all detectors batteries to see if it s in low voltage 3 Check whether wireless detectors can send signal to the main unit normally Check the SIM card 1 Check the use of SIM card such as network signal balance etc 2 Make sure the PIN code verification of the SIM card is closed 3 Please keep the password and SIM card number safe in case that other people remote control the system illegally Since the alarm system is continuously in operation or standby mode the supply adaptor of the control panel shall be connected to a safe and reliable socket x Do not place the system near your bedroom or office table because the siren will make high loudness sound in the case of alarm which may adversely affect your rest or work wif the alarm system will not be used for a long time please disconnect the system from the power supply Please do not disassemble repair or alter the products without x permission or it may cause accidents and faults Do not drop this product on the ground or on hard objects as it may yx lead to massive impact to cause faults and damages Without approval and consent of relevant authorities please do not yx set 110 119 or the alarm phone number of police station for this main unit x Please read the suggestions above carefully and follow the instructions herein If any of the equipment does not work properly please send it to the dealer or authorized se
12. In setup state use keypad to input 57 59 and then press button to confirm The main unit will make a beep the Signal indicator will flicker once and you will hear delete completed which indicate SMS number is deleted successfully Operating method XX gt XX indicates address codes of message receiving numbers from the first group to the third group 57 59 For example delete the first SMS user number from the system Operating method 57 gt 20 SMS Notification for Arm Disarm Default OFF In setup state input the command 77 1 0 1 ON 0 OFF After starting this function the system can send SMS to three SMS receiving numbers 57 59 as mentioned above when the system enters arm disarm status through wireless remote controllers or its panel keyboard operation 21 Defense Zone Programming If you want to change the alarm attribute of defense zone such as turn off the siren when system alarms you can do it by defense zone programming In setup state first input 60 then the defense zone number 01 99 then input defense zone type 1 4 then input alarm type 1 8 and then select siren on off 0 1 at last press to confirm You will hear the main unit emit a long beep and a voice prompt setting completed Operating method 60 AA B C D Functions Settings AA defense zone number 01 99 means zone 1 to zone 99 B defense zone type 1
13. System status There are 4 status as following x Arm defense zone 1 99 will alarm when detectors are triggered x Home Arm in arm status the defense zone which is set as Home Arm will alarm when detectors are triggered x Disarm defense zone 1 99 will not alarm when detector triggered except 24 hours defense zone yx System setup status In this status all defense zones will not alarm when detectors are triggered 2 Remote Controller Operation Users can use remote controller to set system as Out Arm Home Arm Emergency Alarm Real time Disarm and etc yr Out Arm Press button x Disarm Press af button yx Home Arm Press 4 button x Emergency Alarm Press A button system will alarm at once 3 Home Arm It means for the safety while somebody is at home you need to enable the peripheral door window balcony and boundary detectors of the alarm system while prevent from triggering the indoor detectors which may cause improper warning then you shall select Arm at Home let just part of the detectors work and disable the other parts Main Unit Operation Press At Home button on keypad Remote Control Operation Press 4 button on remote controller Operating Instructions LCD display O OOOO 3AN LUUN sf ut U 4 0ut Arm It means to guard all around your house while everyone is going out all the detectors of the host are always working when the detector is trigg
14. alarming system will make alarm call to these numbers automatically Can store 3 SMS numbers when alarming system will send alarming SMS automatically 10 second automatic message recording Built in artificial intelligent digital voice announcer Built in artificial intelligent English message Users can make calls by using keypad on alarm panel just like a telephone One key control function Out Arm Home Arm Remote Arm Arm disarm by SMS or call remotely SOS fire gas door hall window balcony and boundary places alarm Real time delay 24 hours bypass defense zones programming function Wireless coding easy to add additional wireless accessories Remote control Arm Disarm Monitor and Intercom by phone SMS alert for power failure or recovery Built in LI rechargeable battery make alarm when power off Installation Alarm Host Diagram In order to make the main unit get the wireless signal well for all wireless accessories please put the alarm host at the central place of your defense area Make sure it s away from large metal objects and household appliances which may cause high frequency interference as well as barriers such as reinforced concrete wall or fire door etc Alarm Panel front schematic diagram n n LCD Screen gt Alarm Indicator Home Arm Indicator Away Arm Indicator SEE oie ko ee Signal Indicator Setting Indicator BE n w
15. ate use keypad to input 21 then input the remote controller number 1 8 and then press to confirm The main unit emits a long beep and the Signal indicator flickers once You will hear a voice prompt delete completed Operating method 21 c gt A gt A indicates 1 8 remote controllers number 7 Coding of Defense Zone Wireless detectors have to be coded to the main unit in order to trigger it alarm The wireless PIR and door sensor in the standard package have been coded In setup state use keypad to input 23 input the defense zone number you want to code 01 99 and then input to confirm The main unit emits a long beep and the corresponding defense zone is displayed on the screen You will hear a voice prompt detector coding Then trigger a wireless detector to emit a wireless signal after receiving the signal the main unit makes a long beep and you will hear coding completed the indicator goes out at the same time Operating method 23 XX gt XX indicates 01 99 defense zones number LCD display rn E a AaAaRaAS M Functions Settings 8 Delete Defense Zone The wireless detector can t control the main unit after it s deleted In setup state use keypad to input 24 then input the defense zone number you want to delete 01 99 and then input to confirm The main unit emits a long beep and the defense zone indicator flickers once You w
16. atus use keypad to input 36 38 then input the hour AA and minute BB of the time you want to set to disarm and finally input to confirm You will hear a long beep and a voice prompt setting completed Operating method XX gt gt AA gt gt BB gt gt XX indicates the address code 36 37 38 of the timely disarming AA indicates the hour of the setting time BB indicates the minute of the setting time For example set the arm time as 55 7am Operating method 33 gt 22 gt gt 45 gt gt LCD display i hennan 3 Timing Control In setup status use keypad to input 39 then input the number indicating turning on timely arm disarm 1 0 and then input to confirm You will hear a long beep and a voice prompt setting completed The factory default is off Operating method 39 0 1 0 turn off the function of timely arm disarm 1 turn on the function of timely arm disarm For example turn on the function of timely arm disarm Operating method 39 gt 1 gt gt Functions Settings 12 Wireless Transmission Control This function is optional We can make the control panel with built in transmitter so that it would be more convenient to work with wireless siren Only the panel with built in transmitter has this function In setup status use keypad to input 41 then input the number 1 0 and then input to confirm You w
17. e the 7th alarming alarming time 2 10 August 1st 2008 LCD display for one second 1 a array ree ean 7 ECHAN You can also check the alarm records by SMS Max Latest 9 records SMS Check Command Remote Control Password Default 1234 3 Reply SMS Eg Alarm record NO1 Zone 05 TIME 11 06 25 11 37 It indicates the first record wireless zone 5 alarm time NO9 Zone 19 Time 11 06 25 11 45 It indicates the first record wireless zone 19 alarm time 11 GSM Signal Checking Before installing the main unit you should check the signal of the installing place in order to ensure the unit can perform well In setup state input 81 gt the main unit will make a long beep and display 00 XX XX indicates the intensity of the signal And the intensity should be within the range of 07 31 if its less than 07 you should change place This icon fall indicates the signal intensity When the intensity number is 0 7 this icon will not be shown when it s 8 15 this icon will be flashing when the number is larger than 16 this icon will be on the screen without flash For example if the signal intensity is 12 it will display as Care and Maintenance Only under Out Arm status the system has the function of sending SMS alert for power failure power recovery While in Disarm or Home Arm status it does not The SMS content Power failure Power charger off Power recovery Power charger on
18. efense zone 10 will work normally Example set sensor in defense zone 55 not make alarm even when it s triggered under home arm status Operation 61 gt 55 gt 0 gt After this setting when you home arm the system sensor in defense zone 55 will not work 23 Voice Recording In setup state use keypad to input 701 and then press to confirm The main unit will emit a beep and the Cx indicator is on and after 10 seconds countdown recording starts record at 30cm away from the main unit with moderate tone 10 seconds later the main unit will make a beep indicating the recording stops and the recorded voice will replay Operating method 701 gt gt LCD display a Hieied ee J 24 Arm Disarm Siren Sound Setting After you activate this function when you arm the system the external siren will sound one short beep and when you disarm it there will be two short beeps In setting status use keypad to input 75 then 0 1 and finally press to confirm voice prompts setting completed please enter instruction LCD diena Operating Instructions 25 Siren Setting in Emergency Help mode In setup state use keypad to input 76 and then 1 0 finally press to confirm The main unit will make a long beep and a voice prompt setting completed Operating method 76 gt A gt gt A indicates 0 siren off in
19. en Port Positive adhere them to the appropriate Positive of speaker red cable position Negative of speaker black cable Magnet should be near to the eee side of transmitter with indicator 4 GND coma S Wired sensor 1 support both NO and NC The two should align with eachother and the distance should not 6 Zone2 Wired sensor 2 support both NO and NC exceed 10mm Wred sesor 3 support both NO and NU Please plug out the antenna for better signal 8 Zone4 Wired sensor 4 support both NO and NC If the r indicator is on pl hanae the batte 9 Zone5 Wired sensor 5 support both NO and NC SAA PEE nee tea pee re Pe egress i Wired sensor 6 support both NO and NC Less than 10mm X X X X Installation Wireless PIR detector PIR detectors are used to detect the movement within a certain range x Fix the adjustment bracket on TRER 10 30 the wall with the provided screws and attach the Xx detector to the bracket It is recommended to mount it at a height of 2 2 2m above the floor door Effect of the PIR detection is best when the detection direction is in Xx 90 angle with the walking direction of the intruder Choose the most suitable installation place and angle according to actual situation and X taking the following installation diagram as reference to ensure the detection effect is best Please do not fix it under direct sunlight or other strong lights and also keep
20. ered by detecting source anti theft fire prevention gas leak etc the alarm system will sound the alarm Press Out Home button on keypad system will make a beep per second and totally 60 beeps The OUT ARM indicator will be on without flashing It means Out Arm is set successfully Arm Operation Press Out Home button the system will enter arm status 60seconds later LCD display a Ian LUL Sale UU You can also set out arm by SMS remotely The SMS command is Remote Control Password Default 1234 1 After the setting the host makes a Di sound ARM LED is on and you will receive a SMS System armed 5 Disarm It means to stop the alarm when the main unit sounds the alarm or make the alarm system in the state of non warning After disarming even if you trigger the detector the main unit would not sound alarm excluding 24 hour defense areas Use keypad to input system password then press button Out Home or At Home lights will be off It means disarm setting successful Remote Control Operation Press button on remote controller Main Unit Operation input system password CC w A Components List ooa LCD display 2 EI You can also set disarm by SMS remotely The SMS command is Remote Control Password Default 1234 2 After the setting the host makes Di Di sound ARM LED is off and you will receive a SMS System disarmed Note I
21. eusecccseseeccseusecessaess 8 9 Change PASSWOMT ccccsecccssccesseceeeceensceeececesceeeeseasesenscseeseees 8 TO CICK SE 111 9 6 Deen anme ert ne e meer re Ren a 9 TA FAG SO MAGS E A E EE E talekeauans 9 12 Wireless Transmission COntrol cccccssseececeeesseccceeeeseeeeeeeees 11 13 Wireless Siren Coding Encryption ccccccssssccesseceeeneeeeees 11 14 Time Setting of Out Arm Delay cc ecccccsseeccceeseceeeeseeeees 12 15 Time Setting of Alarm Delay ccccccccssseccesseceeesecceeeeeceneeees 12 16 Alarm Number SEMIN G jcc iscensssncectvnstoaursteviactivetoiecsnesenGnedtesaneies 12 17 Delete Phone NUMDET ccccseeccsscccessccesesceeescceasecenscseees 13 CONTENTS 18 SMS Receiving Number Setting cccssscccceeseeeeenseeeees 13 19 Delete SMS Receiving NUMDET sccceseeceeeeeceseeeeeees 14 20 SMS Notification for Arm DiSarm cseccsceeeeeeseesseeeeee 14 21 Defense Zone PrograMmMing cccssssecccccssssecccceesssecceseenees 14 22 Home Arm Defense Zone Setting cccccsecccseeecsceeeeeees 15 29 VOICE Recording sssesseesseeseessessesssessesseesersseeseessesseessessees 16 24 Arm Disarm Siren Sound Setting ccccceecccsssceesssceeeeees 16 25 Siren Setting in Emergency Help mode ccceeeee 17 26 Arm Disarm Voice Prompt ccccccssccecesecccceeseceeeeeeeeeenecees 17
22. f you send arm or disarm SMS by the mobile phone number stored in the system before refer to SMS Receiving Number Setting you will receive two arm disarm SMS 6 Answer Alarm Call When the main unit sounds alarm it will dial the preset numbers If no one answers the call the system will call the next user number automatically The system will call each preset numbers for 3 times in order If you answer the call you will hear the pre record voice You can set system via your telephone or mobile phone keypad If you hang up directly without answering the call the system will call each preset number for 3 times circularly Press Read the alarm information Press 1 Main unit stops alarming and Arm it stops calling users Press 2 Main unit stops alarming and Disarm it stops calling users Press 3 Siren off and monitors the scene for 30 seconds for continued monitoring press 3 again to monitor for another 30 seconds Press 4 Main unit starts a 30 second two way intercom It cannot be controlled by the mobile during the time of intercom Care and Maintenance 7 Remote Control Dial the number associated to the alarm main unit by phone mobile phone and after one ringing cycle you can hear a voice prompt Please enter password If the password is right you will here Press 1 to arm Press 2 to disarm Press 3 to Monitor Press 4 to Intercom If the password is wrong y
23. gits AA of the present year the two digits BB of the month the two digits CC of the date the two digits DD of the hour 24 hour system the two digits EE of the minute the two digits FF of the second and finally enter to confirm You will hear a long beep and a voice prompt setting completed Operating method 32 JAA CBB gt CC c gt DD EE FF col AA indicates the last 2 digits of the present year BB indicates the 2 digits of the present month CC indicates the 2 digits of the present date DD indicates the 2 digits of the present hour EE indicates the 2 digits of the present minute FF indicates the 2 digits of the present second For example set the time as 15 35 40 Oct 1st 2009 Operating method 32 c gt 09 gt 10 01 15 35 40 11 Timing Settings 1 Timely Arm In setup status use keypad to input 33 35 then input the hour AA and minute BB of the time you want to set to arm and finally input to confirm You will hear a long beep and a voice prompt setting completed Operating method XX AA BB CC w 4 g Functions Settings XX indicates the address code 33 34 35 of the timely arming AA indicates the hour of the setting time BB indicates the minute of the setting time For example set the arm time as 45 10pm Operating method 33 c gt 22 c gt 45 gt LCD display J _ E ee ee ee ee ce ee a _ 2 Timely Disarm In setup st
24. ill hear a long beep and a voice prompt setting completed The factory default is off Operating method 41 S gt 0 1 gt 0 turn off the function of wireless transmission 1 turn on the function of wireless transmission For example turn on the function of wireless transmission Operating method 41 gt gt 1 gt LCD display C _ E Hoy Meee a e es ee a e Note after activating this function do as follows to set the wireless siren with the alarm panel Input 411 and then make the siren you want to set into coding status finally press 0 on the panel Pressing 0 means the panel will make coding signal to the siren this signal will last for 3 seconds So please make sure the siren is in coding status during this 3 second period 13 Wireless Siren Coding Encryption Only the panel with built in transmitter has this function The signal used to code with the wireless siren is sent from the internal transmitter of the main panel The signal codes of this product from our company are the same If you and your neighbor both are using this product the alarm signal from your neighbor may cause your siren sound CATU N A y Functions Settings So it is recommended to encrypt the wireless siren to avoid the interference In setup status use keypad to input 43 then input the number 01 99 and then input to confirm You will hear a long beep and a voice prompt setting
25. ill hear a voice prompt delete completed Operating method 24 c gt XX gt XX indicates 01 99 defense zones number 9 Change Password 1 Change Operation Password Operation password is the password used to disarm or remote control In setup status use keypad to input 30 then input the 4 digit new password and then press to confirm The main unit will make a long beep and you will hear a voice prompt setting completed Operating method 30 gt XXXX gt XXXX indicates the new 4 digit password For example change the system password to 1012 Operating method 30 gt 1012 lt gt LCD display 5 as 7 Ao C D 2 Change Program Password Program password is the password you should input in order to setup the system In setup status use keypad to input 31 then input the 4 digit new password and then press to confirm The main unit will make a long beep and you will hear a voice prompt setting completed Operating method 31 gt XXXX gt XXXX indicates the new 4 digit password For example change the system password to 2846 Functions Settings Operating method 31 gt 2846 c gt LCD display 5 ee E E e ee ee eee ee ee _J Note the operation password and the programming password can not be set as the same number 10 Clock Setting In setup status use keypad to input 32 then input the last 2 di
26. it away from places with frequent strong air stream If the low power indicator is on please change the battery MMA Function Settings 1 Initialization Please insert SIM card and plug in power adaptor and then power on the system all the LED lights will be on for 2 seconds and you will hear a long beep the system comes into initialization After the time clock displays on the LCD screen the GSM starts flashing and the main unit starts to detect the GSM network until a long beep Then the GSM indicator goes out indicating the system comes into disarm status Finally turn on the backup battery switch 2 Enter Settings In the state of disarm input 4 digit password by the keypad on the main unit and press button to confirm You will hear a voice prompt please enter instruction At the same time SET indicator is on without flashing and 0000 displays on the screen indicating the system enters setting status You can perform different settings repeatedly as CC Way 4 Functions Settings long as the system keeps in setting status The system will exit setting mode and return to disarm status if you don t press any keypad button for 40 seconds Note In setting status press can delete the numbers input The system default password is 8888 Operating method XXXX gt X indicates the new 4 digit password LCD display j SS E S ee es ee
27. ote the last three functions could be realized only when the GSM signal intensity reaches 20 Care and Maintenance The alarm system has excellent design and uses advanced technologies It shall be used with care The following suggestions are required to maintain your obligations under the warranty terms and for prolonging the service life of the system x Place the control panel and all parts and accessories out of children s reach Xx Keep the alarm system dry Rain humidity and various fluids or moisture all will corrupt the electronic circuit x Do not use or place the alarm system in dirty locations otherwise the electronic elements will be damaged x Do no place the system in excessively hot locations High temperature will shorten the service life of electronic equipment damage batteries deform or even melt some plastic parts x Do not place the system in excessively cold locations Otherwise condensation many occur and damage the circuit board of the alarm system X It is recommended that you check and test the alarm system periodically Check the main unit every three months 1 Whether it can arm disarm normally 2 Whether it can dial the number for alarm normally 3 Whether it can receive wireless detectors signal normally 4 Whether the back up battery can work normally CC Way 4 Care and Maintenance Check the wireless detectors once a month 1 Trigger wireless detectors to see if
28. ou will hear a prompt voice wrong password please re enter Press 1 arm if finished successfully you will hear a voice prompt System armed Press 2 disarm if finished successfully you will hear a voice prompt System disarmed Press 3 monitoring for 30 seconds to continue monitoring press 3 again to monitor for another 30 seconds Press 4 two way intercom for 30 seconds You can t operate the main unit during this time 8 Emergency Help Press Emergency button on keypad or iA button on remote controller or wireless panic button the main unit will alarm and make call to the preset user numbers 9 System Dialing Function In disarm status you can use the main unit to make any call just like a land line telephone Dial telephone number on keypad press button the main unit will make a beep and the Signal indicator will be flashing After the call press button again the main unit will be in disarm status 10 Alarming Record Checking In disarm state input 0 then the main unit will make a long beep and enters the state of alarm record checking After displaying the alarm and defense zone number indicator the LCD screen will display the exact alarming time of this defense zone Press 2 you can upturn to check the previous alarming record press 8 downturn to check and press to exit checking CU Wa A Care and Maintenance For example the 51st defense zon
29. rvice point for repair We will try our best to solve the problem for you as soon as possible Care and Maintenance Signal booster Wireless Keypad Wireless Outdoor Flash Siren wd Door sensor Panic Button Remote controls kaca i N aN j e 7 Smoke Detector Gas Detector PIR detector Optional sensors detectors are packed separately You can choose according to your specific requirements Typical house configuration External Sirens irre

Download Pdf Manuals

image

Related Search

Related Contents

Règlement jeu-concours M6 MOBILE BY ORANGE Jeu Jean  User`s Manual TN960 テレサート標準ソフト 取扱説明書  BT-001 - acadalus  Micro Hi-Fi System  General Warning  - NEC Display Solutions Europe  User Manual – v3.0  Classic Accessories 10-012-251001-00 Instructions / Assembly  OPERATING INSTRUCTIONS MANUAL FOR “HMS MF  CTK6000_WK6500 - Support  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.