User`s Manual Earth Ground Resistance Tester
Contents
1. 382252 EU EN V1 2 1 12 Maintenance Battery Replacement When the low battery icon appears on the LCD the meter s batteries must be changed Remove power and disconnect the test leads from the meter Remove the tilt stand from the rear of the meter Remove the 4 battery compartment screws with a Phillips head screwdriver Remove the battery compartment cover and replace the six 1 5V AA batteries Affix compartment cover and tighten screw Reattach the tilt stand You as the end user are legally bound Battery ordinance to return all used batteries and accumulators disposal in the household garbage is prohibited You can hand over your used batteries accumulators at collection points in your community or wherever batteries accumulators are sold E Disposal Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle oa fF wn gt Cleaning and Storage Periodically wipe the meter s case with a damp cloth and mild detergent do not use abrasives or solvents If the meter is not to be used for a period longer than 60 days remove the batteries and store them separately Specifications General Specifications Measurements Display Sampling Time Test lead length Over range indication Power supply Low battery indication Auto Power Off Safety Weight Dimensions Supplied accessories Operating Conditions Storage Conditions Eart
2. N V1 2 1 12 Meter Description 1 Digital Display See Display Description below HOLD key Freezes measurement value on display carr gA g 0 ADJ control Adjusts Zero value on display Backlight key Turns on Backlight TEST key Enables Earth Resistance and Earth Voltage Tests ow ON 6 Function Selector switch Selects desired range and function Top View 1 VQ C Input 2 P Input 3 COM E Input Display Description 12 3 1 Test status Icon 1 2 2 Battery Charge indicator 3 Voltage Unit indicator ane KIE ae 9 ULL 4 Audible Signal Icon g 220 HoLb 3 pe Ty ay V tn 7 IUUIU 5 Q kQ Units Indicators las Van Va D 4 6 Measurement Value Li 7 AC DC Voltage Indicators 8 Low Battery Icon 9 HOLD Icon 3 Model 382252 EU EN V1 2 1 12 Operation 0 Adjustment 1 Connect the test leads to the meter as follows a Green lead to the E terminal b Yellow lead to the P terminal c Red lead to the C terminal Set the function selector switch to the desired measurement range Short the 3 test leads together Press the TEST key Use the 0 Adjust knob to adjust the displayed reading to 0Q eS ao FY DN Press to TEST key again to end the 0 adjustment process Test Connection Diagram 1 382252 Meter Green Test Lead Yellow Test Lead Red Test Lead Existing Ground P1 Auxiliary Earth Bar C1 Auxiliary Earth Ba
3. User s Manual EXT INSTRUMENTS A FLIR COMPANY Earth Ground Resistance Tester Kit Model 382252 Introduction Congratulations on your purchase of the Extech 382252 Earth Ground Resistance Tester Kit This device can measure Earth Ground Resistance in 3 ranges Earth Voltage and Resistance up to 200kQ and AC and DC voltage This device was designed to meet EN61010 1 safety standards Careful care and use of this meter will provide years of reliable service Safety Please read the following safety information carefully before attempting to operate the meter and use the meter only as specified in this manual Environmental safety information e Do not use meter outdoors when precipitation is likely e Installation Category III e Pollution degree 2 e Altitude 2000 meters max e Ambient conditions 32 to 104 F 0 to 40 C RH 80 max e Observe the following international safety warning symbols Safety Symbols Caution Refer to this manual before using this meter A Dangerous Voltages O Meter is protected throughout by double or reinforced insulation Organizations that provide rules and guidelines for proper grounding e The National Electrical Code NEC e Underwriters Laboratories UL e National Fire Protection Association NFPA e American National Standards Institute ANSI e Occupational Safety Health Administration OSHA e Telecommunications Industry Standard TIA 2 Model 382252 EU E
4. ected note the value and take appropriate steps to correct the ground connection if necessary Press to TEST key to end the test 6 Readings of 1 are typical when the test leads are not connected to the meter HOLD Function The Hold function freezes the latest measurement reading on the LCD 1 Press the HOLD key to freeze the reading on the LCD 2 Press the HOLD key again to exit the HOLD function 3 The HOLD function does not retain measurement data if the meter is turned off Backlight 1 Press the key to turn on the backlight 2 The backlight will turn off after approximately 15 seconds 200kQ Resistance Measurement 1 Connect the red test lead to the VQ connector and the black test lead to the COM connector 2 Set the function selector switch to the 200kQ position 3 Connect the test probes to the circuit or component under test 4 Note the displayed Resistance value AC Voltage Measurement Connect the red test lead to the VO connector and the black test lead to the COM connector Set the function selector switch to the 750V AC position Connect the test probes to the circuit under test ON Note the displayed Voltage value DC Voltage Measurement Connect the red test lead to the VO connector and the black test lead to the COM connector Set the function selector switch to the 1000V DC position Connect the test probes to the circuit under test Pe NS Note the displayed Voltage value 5 Model
5. h Ground Resistance in 3 ranges Earth Voltage AC Voltage to 750V and DC Voltage to 1000V Large LCD with dual display 2 5 times per second Red lead 50 15m Yellow 33 10m Green 16 5m 1 displayed as most significant digit Six 1 5V AA batteries included LCD displays icon After approximately 15minutes of use EN 61010 1 category III 700g 24 70z with batteries 200 x 92 x 50 mm 7 9 x 3 62 x 2 Multimeter Test leads 2 Earth Ground test leads 3 auxiliary earth bars 2 six AA batteries and carrying case 0 C to 40 C 32 F to 104 F with lt 80 RH 10 C to 60 C 14 F to 140 F with lt 70 RH 6 Model 382252 EU EN V1 2 1 12 Measurement Specifications 0 010 2 reading 10 digits Resistance 20a Resistance 2 reading 3 digits 20002 19 Earth Voltage 0 to 200VAC Frequency 40 to 0 1V 3 reading 3digits 500Hz 0 to 200kQ 0 1kQ 1 reading 2 digits Resistance Overload Protection 250 Vrms AC Voltage 0 to 750V 1 2 reading 10 digits 40 Hz to 400Hz Overload Protection 750 Vrms Input Impedance 10MQ 0 to 1000V 0 8 reading 3 digits DC Voltage Overload Protection 1000 Vrms Input Impedance 10MQ TEquipment An Interworld Highway LLC Company 7 Model 382252 EU EN V1 2 1 12
6. r EN OY ON Be ON Test Preparation and Setup 1 Connect the test leads to the meter 1 as follows Green lead 2 to the E terminal e Yellow lead 3 to the P terminal e Red lead 4 to the C terminal 2 Drive the Auxiliary Earth Bars P1 6 amp C1 7 into the ground Align the bars equidistant to the existing Earth ground connection and in a straight line as shown in the diagram above If the auxiliary bars are placed in close proximity to the ground stake measurement inaccuracies will result 3 Connect the clamp ends of the test leads to the Earth bars and existing ground connection as shown above Green lead 2 to the existing ground 5 e Yellow lead 3 to Earth Bar P1 6 Red lead 4 to the Earth Bar C1 7 4 Model 382252 EU EN V1 2 1 12 Earth Voltage Test 1 Set the function on the selector s switch to the EARTH VOLATAGE position 2 Confirm that the voltage measurement is less than 10V AC otherwise accurate Earth resistance measurements cannot be made If voltage is present higher than 10V AC the source of the voltage must be found and corrected before testing can continue 3 Press to TEST key to end the test Note the LCD reading Earth Resistance Test 1 Set the meter s function switch to the desired resistance range 2 Press the TEST button The f icon will flash and the audible signal will sound 3 Note the displayed reading 4 lf high resistance is det
Download Pdf Manuals
Related Search
Related Contents
Plus qu`un simple Salon un média à grand impact ! Plus utile M55_6 ECU deutsch V2-7 - NEWA Ltl Acorn Ltl-SUN - Ltl Acorn AUSTRALIA Samsung SGH-M919RWATMB User's Manual Strategi user guide: D05300_05 Manual 3D V.11 DE Betriebsanleitung Niederdruckpumpen EVGA 256-P2-N753-BR NVIDIA GeForce 8600 GT 0.25GB graphics card Copyright © All rights reserved.