Home

user manual optima-rack 1k – 3kva - xmart-ups

image

Contents

1. Charging Voltage Voltaje Cargador 120Vac Model 120V 80Vac 150Vac Model 220V 160Vac 300Vac Model 120V 50Vac 150Vac Model 220V 110Vac 300Vac 45 Hz 65Hz gt 0 99 lt 7 Q 100 load Model 120V 110 115 120 127Vac Model 220V 208 220 230 240Vac 1 N3 50 Hz 0 2Hz 60Hz 0 2 Hz 3 1 lt 2 Linear Load Carga Lineal lt 6 Non Linear Load Carga NO Lineal 0 ms Pure Sinewave Sinusoidal Pura gt 93 gt 93 gt 86 gt 88 Sealed Lead Acid VRLA AGM Sellada de Libre Mantenimiento VRLA AGM 12V 7AH x 3 pcs 12V 9AH x 3 pcs 12V 7AH x6 pcs 12V 9AH x 6 pcs 41 0 VDC 1 41 0 VDC 1 82 1 VDC 1 82 1 VDC 1 12V 9AH x 2 pcs 12V 9AH x 3 pcs 12V 9AH x 4 pcs 12V 9AH x 6 pcs Capacity Qty Capacidad Cantidad 220Vac 274 WDC 1 41 0 VDC 1 54 8 VDC 1 82 1 VDC 1 Charging Voltage Voltaje Cargador 220Vac Typical Recharge Time T de Recarga Charging Amps Corriente de Carga INDICATORS INDICADORES LCD Pantalla de Cristal Liquido LCD PHYSICAL FISICAS UPS RACK Type Model 120Vac Total Power Outlets T otal Salidas D X W XH Prof X Ancho X Altura Net Weight Peso Neto kgs UPS RACK Type Model 220Vac Total Power Outlets T otal Salidas 220Vac D X WXH Prof X Ancho X Altura Net Weight Peso Neto kgs External Battery Cabinet Tower Batt Capacity Qty Capacidad Cantidad Bater as OPERATING CONDICIONES DE OPERACI N Operation Humidity
2. Humedad de Operaci n Operating Temperature Temp de Operaci n Noise Level Ruido Producido COMMUNICATION COMUNICACION Smart RS 232 4 USB Intelligent Port 120217_EN OPTIMA RACK 1K 3K 4 Hours for 90 capacity 4 Horas para recuperar el 90 de carga 1 0 A Max UPS Mode Load level Battery Input Output Discharge timer amp Fault messages NEMA15x4 NEMA15x4 NEMA15x8 NEMA 20x 4 480x438x88mm 2U 480x438x88mm 2U 600x438x88mm 2U 600x438x88mm 2U 18 4 18 5 25 7 29 CEE 7 4 Schuko x 2 CEE 7 4 Schuko x 2 380x438x88mm 2U 480x438x88mm 2U 480x438x88mm 2U 600x438x88mm 2U 13 2 18 5 20 6 29 480x438x88mm 2U 600x438x88mm 2U 12V 9AH x 6 12V 9Ah x 12 lt 95 RH non condensing no condensante 0 40 C lt 45dBA 1m Win 98 SE ME NT 4 x 2000 2003 XP Vista 2008 Win Linux Unix Mac OS LAN Card SNMP type optional Comunicaci n con LAN mediante SNMP opcional AS400 Interface optional comm Card Interfazcon AS400 tarjeta opcional 26
3. INSTRUCTIONS TO CONNECT EXTERNAL BATTERIES 1 Place EX BATT case close to UPS Only XMART approved EX BATT can be connected to UPS EX series 2 Check DC breakers are in OFF position circuit OPEN 3 Connect UPS to first EX BATT using XMART approved DC cable 4 If more than one EX BATT will be connected then connect first EX BATT to second EX BATT and so on in that way to other EX BATT 5 After all EX BATT are connected switch to ON position all DC breakers located in EX BATT Important Note It is not recommendable to connect more than 3 external battery packs to the UPS since recharging time could be too long External Battery Cabinet Characteristics Model EX BAT R3 Total Batteries 12 pieces per cabinet 2 internal packs of 6 batteries 12V 9AH Voltage DC 82 1Vdc 1 Application OPTIMA Rack 3K EX 4 CONFIGURABLE PARAMETERS Any configuration modification must be applied with UPS connected to AC line but in OFF or STAND BY mode This UPS can be configured to work under some different modes Some important functions can also be configured in CONFIGURATION MODE a Normal Mode Also known as AC MODE Under this mode UPS works as ONLINE UPS UPS outlets are supplied by AC power generated by UPS inverter circuit offering a clean power to your devices b ECO Mode Under this mode UPS works as OFF LINE UPS UPS outlets are supplied by AC input source UPS supervises input source to switch to ONLINE mode only when in
4. OP Indicates time in battery mode H hours M minutes S seconds Failure Messages Indicates failure detected lt A A Indicates number code for detected failure Error or Failure codes are listed in this manual Indicates MUTE function is active Under this mode beeper is disabled OUTPUT Information m 7 Vac Indicates output values related to AC voltage output frequency it m 0 ee Vac Volts AC Vde Volti DC Hz frequency units a py zZ OUTPUT 120217_EN OPTIMA RACK 1K 3K 12 USER MANUAL Optima Rack 1 3K Power consumption connected to UPS outlets uy Indicates power output supplied by UPS R 0 25 26 50 51 75 y 76 100 Indicates overload at UPS output Devices connected in UPS outlets load UPS above UPS capacity Indicates short circuit at UPS output Indicates programmable function is activated Indicates UPS is in BYPASS mode Indicates ECO Mode is active Indicates UPS inverter is running Indicates UPS outlets are powered Battery Information A Indicates battery charging level i 0 25 26 50 TE 51 75 y i 76 100 i ac iF E un LOW BATT Indicates low battery level Input Information ocd Vac Indicates input voltage input frequency and DC battery voltage a Wad Mi OO y Vac Input voltage Vdc battery voltage Hz input frequency INPUT 12 120217_EN OPTIMA RACK 1K 3K 13 USER MANUAL 0 mare Optima Rack 1 3K BEEP
5. UPS overloaded Intermittent OVER LOAD 2 beeps per second UPS overloaded UPS has Disconnect devices from UPS Intermittent J OVER LOAD changed to BYPASS mode to outlets until solving overload 2 beeps per second avoid internal damage By Pass activated After repetitive small overloads Disconnect devices from UPS UPS has changed to BYPASS outlets until solving overload mode Then power off UPS and re star again Code 43 UPS has been automatically Disconnect devices from UPS powered off because overload outlets until solving overload Active OVER LOAD Then power ON Continuous beep UPS has been automatically Check short circuit problem in Active SHORT on LCD powered off because short devices connected to UPS Continuous beep circuit detected at output Disconnect devices from UPS outlets until solving overload 120217_EN OPTIMA RACK 1K 3K 20 USER MANUAL Optima Rack 1 3K Any of following codes indicated on Internal Ups failure detected Call service support LCD UPS working in any of following 1 2 3 4 11 12 13 0 41 modes Continuous beep 1 UPS output powered in BYPASS mode 2 UPS outlets powered off Very short backup time Batteries can be discharged Let UPS recharge batteries because recent use during 6 hours before check backup time again Battery can be degraded Batteries must be replaced by because long lifetime new batteries m FANSs bl
6. same time 09 Programmable Outlets Timer setting UPS is OFF 0 999 to configure timer limit in minutes for powering off No power in UPS outlets programmable outlets STAND BY Input AC source is OK Batteries are been charged 9 LCD screens depending of Operation Mode Operation Mode 10 ERROR FAILURE CODES ON LCD FAILURE ERROR CODE UPS ON Input AC source OK UPS output generated by inverter ONLINE UPS in ON ECO mode activated Input AC source is OK 2 3 g vee 3 O vac Inverter output short circuit 14 UPS output feed from AC input to save MES pai ee I Battery Very High Voltage el energy UPS in ON ECO mode activated Input AC source out of acceptable range UPS output generated by inverter CF function enable to generate output FREQUENCY frequency as selected CONVERTER FUNCTION When AC input source is out of range yi TWO Ups goes to battery mode to supply Zz E JE BATTERY MODE output from taking energy from batteries Be Teg gi g 3 u jj 120217_EN OPTIMA RACK 1K 3K 17 120217_EN OPTIMA RACK 1K 3K 18 USER MANUAL Optima Rack 1 3K 11 ALARMS ON LCD ALARM Description ICON on LCD Beep Alarm Low batter 1 s LOW BATT Overload hi power consumption detected at 2 s UPS output A q UE Ts Batteries overcharged Input Cable failure FAN failure RA Battery charger problem CHA Input out of range in bypass mode I
7. will be safe when your PC related equipment is connected to OPTIMA series UPS Power output is sine wave type same as supplied by AC main source Depending of AC input source this UPS can work under one of two following modes Normal AC Mode lt is the default mode when AC input source is OK Under this mode power output is generated by UPS inverter Inverter takes power from AC DC converter feed by AC input source AC input source is only used under this mode to recharging batteries when necessary Battery Mode Also known as Inverter Mode It is the mode when AC input source is out of range or black out is detected by the UPS Under this mode power output is generated by UPS inverter that takes power from batteries There is no dead time transition time is ZERO ms related to switching from normal mode to battery mode since load is always powered from inverter This is main characteristic of an ONLINE UPS ECO Mode This UPS also offer a third operation mode name ECO MODE Under this mode selectable by LCD configuration menu UPS works as OFF LINE UPS Load is powered from AC input and UPS only switch to battery mode when input is out of range or in black out status Transition time from ECO mode to Battery mode is not zero Typically is about 4ms that is why ECO Mode is not recommended for critical applications 120217_EN OPTIMA RACK 1K 3K 11 USER MANUAL Optima Rack 1 3K 6 FRONT LCD PANEL ermer j N S n A lca ipa
8. 4 USER MANUAL Optima Rack 1 3K 2 B PRODUCT DESCRIPTION REAR PANEL 120V AMERICA NEMA Outlets Programmable Outlets Standard Outlets AC Input Input Breaker Protected LAN network jacks EPO Emergency Power Off USB port RS 232 port Intelligent Slot for SNMP LAN cards Connector for External batteries EX models Output Breakers e dl oe OPTIMA RACK 1KVA 1 5KVA 6 7 2 1 4 a Tn 10 8 9 3 OPTIMA RACK 2KVA 7 6 1 5 A 10 8 9 2 3 OPTIMA RACK 3KVA 6 1 3 5 gol 10 8 9 11 2 120217_EN OPTIMA RACK 1K 3K 5 USER MANUAL Optima Rack 1 3K FRONT PANEL PUSH BUTTON FUNCTIONS SELECT OFFERTER 7 i ON MUTE a POWER ON Keep selected during 2 seconds or longer b BEEP MUTE In battery mode Keep selected during 5 seconds or longer to Mute acoustic alarm beep Some alarms cannot be muted as Bypass Warning or ERROR alarms c AUTO TEST In normal mode Keep selected during 5 seconds or longer to activate Auot Test function OFF ENTER a POWER OFF UPSAPAGADO DEL UPS Keep selected during 2 seconds to power off UPS b ENTER Enter function works under configuration mode only lt works as confirmation or selection key for accepting current option on LCD SELECT a TO SHOW UPS PARAMETERS AND VALUES It is used to show on LCD UPS input and output values as AC Input DC battery voltage Input Frequency UPS output output frequency etc b TO ACTIVATE CONFIGUR
9. ACK 1K 3K 8 USER MANUAL Optima Rack 1 3K mart First Time CHARGE BATTERIES FOR 6 HOURS BEFORE CONNECTING YOUR EQUIPMENTS TO UPS e This product leaves factory with battery fully charged however during transportation and storage it may loose a non determined part of its charge therefore we recommend plugging it to Power Line for 6 hours before using the UPS e Install this unit in any protected environment with a dust free air flow Also corrosive vapours and conductive contaminants must be avoided Do not use UPS outdoors or where either temperature or humidity exceeds tech specs Install UPS at least 10 inches away from your monitor to avoid magnetic interference 1 Plug input AC power cord to an appropriate power outlet with Line Neutral Ground contacts e Some models come with input power cord with appropriate plug for your country e 3KVA in 120V could come with input terminal block For 3KVA 120V models input cable to be connected to input Terminal Block must be AWG12 or wider for lengths shorter than 50 feet 15m Wire size is strongly affected by length and temperature Input wire must be selected and installed by qualified personnel according to local regulations 2 First time leave UPS recharging batteries during 6 hours before connecting your devices to the UPS to let batteries recover charging level to offer full battery backup time 3 Connect your devices to be protected to UPS outlets Take care to not o
10. ALARM Battery Mode 1 Beep every 4 seconds Battery Low 1 Beep per second Output Overload 2 Beeps per second UPS Failure Continuous Beep By Pass Mode 1 Beep every 10 seconds 7 LCD TEXT MESSAGES ENA EIA Enable Habilitado High Limit for Baypass Limite Alto para Bypass Low Limit for Baypass Limite Bajo para Bypass Converter Convertidor de Frecuencia EPO Emergency Power Off Temperature Temperatura cH Charger Cargador de Baterias 120217_EN OPTIMA RACK 1K 3K 14 USER MANUAL Optima Rack 1 3K 8 UPS CONFIGURATION me lt N i ree YA i iy Ha q O e t Tea Ta q ae os gt ae a oot Configuration menu is activated by selecting SELECT push button at front panel during 5 seconds or longer UPS must be connected to input AC source but in stand by mode powered off OFF Enter button is used as confirmation key Enter ON Mute is used to select upper option in menu SELECT is used to select bottom option in menu Configuration Menu 00 Initial Menu Quit option 01 Output Voltage 02 CF Frequency Conversion Mode to able or disable 03 CF for configuring frequency value in Hz 04 ECO to Able or Disable ECO Mode 05 ECO To configure acceptable input voltage range in ECO mode 06 By Pass To able or disable by pass functio
11. ATION Keep selected during 5 seconds or longer ON MUTE SELECT TO ACTIVATE BY PASS MODE Under normal mode by selecting these 2 keys at the same time during 5 seconds or longer UPS changes from normal mode to bypass mode 120217_EN OPTIMA RACK 1K 3K 6 USER MANUAL mart Optima Rack 1 3K 3 INSTALATION 3 1 INTERNAL BATTERIES CONNECTION BEFORE INSTALLING Before installing this product internal batteries must be connected This product is delivered with internal batteries disconnected to avoid battery damage during long storage times Step 1 Open and remove front cover Step 3 Close front panel 120217_EN OPTIMA RACK 1K 3K 7 USER MANUAL Mart Optima Rack 1 3K 3 2 RACK UPS INSTALLATION Rack UPS must be installed using L Shape type guides for supporting UPS weight Usually this kind of supports is provided with rack cabinets If not XMART can provide telescopic guides as optional accessory Small black handles included with the UPS are only for locking purposes UPS cannot be supported only by these handles Figure 1 Rack cabinet must include L shape guide to support UPS Figure 2 UPS must be installed on L shape guides Figure 3 Handles included with UPS are only for locking UPS to the cabinet but not for supporting UPS weight Figure 4 XMART offers telescopic guides as optional accessory if it is required Figure 1 Figure 2 Figure 3 Figure 4 120217_EN OPTIMA R
12. N BYPASS 12 TROUBLESHOOTING TABLE Problem Description Probable Root Cause Suggested Action Input power cord is not Check input power cord LCD does not show input voltage value connected connection AC input failure alarm active 1 beep 4s however AC input source is Input power cord is connected Check input power cord into UPS outlet connection UPS cannot be powered on even AC EPO function is active Re establish emergency power input is OK off switch and set UPS in normal Beep alarm is active 1 beep s amp LCD mode shows A EP 120217 _EN OPTIMA RACK 1K 3K 19 USER MANUAL Optima Rack 1 3K UPS cannot be powered on even AC ON push button is not been Push ON button during 2 input is OK selected properly seconds or longer 1 beep s alarm is active and LCD Input Line and Neutral are Rotate UPS plug at wall socket shows swapped to allow correct line neutral connection This suggestion is only valid for Schuko power plug type 1 beep s alarm is active and LCD Internal or external batteries are Check battery connection shows not properly connected Code 27 Very high voltage at batteries or Batteries and charger must be BATT FAULT charger failure inspected by qualified personnel Active Continuous beep Code 28 Very low voltage at batteries or Batteries and charger must be BATT FAULT charger failure inspected by qualified personnel Active Continuous beep
13. USER MANUAL Optima Rack 1 3K ENGLISH USER MANUAL OPTIMA RACK 1K 3KVA ONLINE DOUBLE CONVERSION UPS User Manual e 220V Europe Schuko Zone e 110V America NEMA Zone Xna Optima 120217_EN OPTIMA RACK 1K 3K 1 w USER MANUAL Optima Rack 1 3K 1 SAFETY AND USE WARNING This product has been designed to operate safely and reliably for years Nevertheless as it is an electrical device it is required to read and understand this manual Keep manuals as references for future consults WARNING This product has been designed to be used indoors protected of water direct sun light and extreme temperatures This device must not be used outdoors close to moisture of heat sources WARNING Do not set objects on this UPS Handle with care Do not block UPS ventilation WARNING Make sure to connect this unit to proper power line according to selected model The UPS Technical Specs sticker shows power rating information DO NOT connect this UPS to any of its own power outlets WARNING UPS must be installed following instruction from this manual The manufacturer is not liable for any damage that might rise from misusing this unit or defective installation WARNING Only computer related equipment can be connected to this UPS DO NOT connect medical equipments life support equipments microwave ovens vacuum cleaners refrigerators or any other appliance to this UPS WARNING UPS must be checked repaired and
14. epaired or replaced product will be warranted for the remaining time of the original warranty or for 90 days from date of repair or replacement whichever is longer 5 XMART or their distribution service partners reserve the right to charge handling fee if returned product is free of failure or out of warranty period because any of the reasons described in this warranty 6 If product is out of warranty a reparation or replacement proposal will be sent to the user for his approval If customer does not approve reparation product will be available to be picked up during 60 days After this period product would be disposed by service center and user will not be able to rises any claim 7 Rechargeable batteries will definitively wear out even under normal operation and conditions This is not a defect or failure so that it is not covered by this warranty 8 Warranty does not cover product failures caused by improper storage or longer than 6 months storage without required recharging inadequate installation or maintenance misuse accidents fire or floods In these cases warranty will be considered void 9 This warranty does not cover product failures caused by installations modifications or repair or opening of the product performed by non authorized person 10 This product can include protection devices like input fuse or input breaker Activation of this kind of devices is not a failure it is caused by an improper product installation Inpu
15. maintained by qualified personnel only This product is locked by Screws WARNING ELECTRIC SHOCK RISK Inside the UPS there are dangerous high voltages even when disconnected of power line due to internal batteries WARNING In case of emergency turn off the UPS pressing Power Button unplug it and call technical support DO NOT connect laser printers scanners or copiers to this UPS High power devices may damage this UPS Disposal We strongly recommend disposing this UPS according to regulations in your country to prevent possible environmental damages besides some parts might be recycled BATTERY WARNING DO NOT dispose batteries in fire as it might explode DO NOT try to open batteries there are dangerous liquids inside 120217_EN OPTIMA RACK 1K 3K 2 USER MANUAL Optima Rack 1 3K Safety Standards OPTIMA amp OPTIMA RACK 1KVA 1 5KVA Low Voltage Directive EN62040 1 1 2003 An Uninterruptible Power Systems UPS Part 1 1 General and Safety Requirement for UPS use operator access areas EMC Directives EN62040 2 2006 An Uninterruptible Power Systems UPS Part 2 Electromagnetic compatibility Class 2 EMC IEC 61000 4 2 2001 Electrostatic discharge immunity test IEC 61000 4 3 2006 Radiated radio frequency electromagnetic field immunity test IEC 61000 4 4 2004 Electrical fast transients Burst immunity test IEC 61000 4 5 2005 Surge immunity test IEC 61000 2 2 2002 Compatibility levels for low frequenc
16. n 07 By Pass To configure acceptable input voltage range 08 Programmable Outlets To able or disable programmable outlets function 09 Programmable To configure timer value in minutes for programmable outlets 120217_EN OPTIMA RACK 1K 3K 15 USER MANUAL Optima Rack 1 3K 120217_EN OPTIMA RACK 1K 3K Output voltage value can be selected from 4 available values CF ENA CF function enable CF DIS CF function disable Output frequency can be configured for battery mode BAT 50 50Hz BAT 60 60Hz If CF function is enable output frequency can be set in normal mode CF 50 50Hz CF 60 60Hz ENA ECO enable ON DIS ECO disable OFF By Selecting UP DOWN on mute y select keys for selecting hi limit HLS and low limit LLS of input range in ECO mode ENA Bypass enable DIS Bypass disable By Selecting UP DOWN on mute y select keys for selecting hi limit HLS and low limit LLS of input range in By Pass mode 16 USER MANUAL De USER MANUAL Optima Rack 1 3K Optima Rack 1 3K If UPS is overloaded by big consuming 08 Programmable Outlets Enable or Disable load connected at UPS output UPS S amp S Ngu ENA to enable programmable function changes to BYPASS mode feeding En DIS to disable programmable function BYPASS outlets from input AC source This mode gt i can be set also by front panel by selecting ON MUTE SELECT at mo l gt
17. ocked or damaged Check FANs and call service Intermittent A iF A support if problem cannot be 1 beep per second solved 13 CONTROL SOFTWARE Our control software offers huge capabilities to monitor your UPS and configure key shutdown parameters Also event and data log are available in software options Main software features are e Friendly human interface to UPS e Controlled files saving and OS shutdown when blackout is detected e Configurable scheduled shutdown and Auto tests Some UPS models include software CD inside the box Others allow software downloaded from our website www xmart ups com 120217_EN OPTIMA RACK 1K 3K 21 y USER MANUAL Optima Rack 1 3K 14 WARRANTY AND SUPPORT Support When a failure or problem is detected please check troubleshooting table in this manual If problem cannot be solved please contact authorized service center or authorized dealer Batteries Rechargeable batteries can be charged and discharged hundreds of times However they will eventually wear out This is not a defect or failure so that batteries wear out is not covered by warranty Battery lifetime will depend of operative conditions like working temperature and type and frequency of discharging cycles Higher the temperature shorter will be the lifetime Frequent and deep discharging cycles also will short lifetime For critical applications batteries should be revised and replaced periodically Long storage without required
18. put source is out of range This is not a recommendable mode for those critical applications that require ONLINE UPS Default mode set as factory is NORMAL MODE Online UPS c Output Voltage It can be configured to any of 4 available values In 120Vac Models 110Vac 115Vac 120Vac 127Vac In 220Vac Models 208Vac 220Vac 230Vac 240Vac d Output Frequency It can be selected to 50Hz or 60Hz Default configuration allows auto selection to match with frequency of input AC source NOTE When conversion frequency mode is activated UPS power capacity can be reduced e Programmable Outputs There are 2 group of outlets e Standard Outlets They works as expected in any UPS This kind of outlets under battery keep powered until batteries reach very low level or up to UPS receives power off command from software e Programmable Outlets If programmable outlets function is configured programmable outlets can be powered off by internal timer before UPS detects very low battery level Most common application for programmable outlets is for connecting non critical devices to them so that backup time can be longer for those critical devices connected in standard outlets 120217_EN OPTIMA RACK 1K 3K 10 USER MANUAL Optima Rack 1 3K 5 OPERATION This is UPS is ONLINE DOUBLE CONVERSION type and it has been designed to offer the most clear power without switching transitions or dead times In that way your hardware but also your valuable data
19. r Products 15 BATTERIES MAINTENANCE NAD REPLACEMENT Step 5 Reconnect battery kit to UPS Step 6 Close front cover 15 1 Battery Care When battery backup time is noticeable shorter it is time to replace batteries To get longer lifetime we recommend applying a deep discharge every 3 months Operation temperature should be below 25 C When UPS is storage periodic recharge must be performed as indicated in below table Storage Temperature Recharge Frequency Recharge Time 6hours 25 C to 30 C 6 hours 30 C to 45 C 15 2 Batteries Replacement This UPS has been designed to allow easy and safety battery replacement 15 3 Battery Assembly Instructions Si 1 Remove front cover and disconnect internal Step 2 Take out battery kit from UPS Battery quantity depends of UPS model Check specification table to know battery quantity and type for your UPS atteries 3 Batteries Kit 1 Remove batteries from plastic assembly 2 Connect new batteries in series as indicated below Step 3 Replace old batteries using equivalent batteries with same voltage and capacity in AH Follow instructions of 15 3 5 Using a DVM check battery assembly DC voltage is closet o 37 5 Vdc 3 x 12 5Vdc each If measured voltage is not correct probably there is a wrong connection Check correct and confirm 120217_EN OPTIMA RACK 1K 3K 23 120217_EN OPTIMA RACK 1K 3K 24 USER MANUAL mart Optima Rack 1 3K Quali
20. recharging will wear out batteries This situation is not covered by this limited warranty since this is not considered as a defect Check recharging instructions on user manual Conditions Limited Warranty Xmart PRO11 1 Subject to the conditions of this limited warranty this product is warranted to be free from defects in materials and workmanship at the time of its original purchase by end user and for subsequent period of 1 year on electronic parts and 1 year on batteries This standard warranty time could be extended depending on the country region or as an option Please check warranty times by country region in our web www xmart ups com 2 If during the warranty period this product fails to operate under normal use and service due to defects in materials or workmanship authorized distributor or service center will at their option either repair or replace the product in accordance with terms and conditions stipulated herein Transportation expenses are not covered by this limited warranty 3 Warranty is valid only if the original purchasing document issued to original purchaser by authorized distributor or dealer specifying date of purchase serial number and name of the dealer is presented with the product to be revised XMART and authorized partners reserve the right to refuse warranty service if any of this information has been removed changed or missing in original purchasing document 4 If product is repaired or replaced r
21. t fuse or breaker can be easily reset or replaced by user 11 This warranty does not cover damages produced during transportation from user to technical service caused by improper packing of the product by user 12 Warranty time could be extended depending on market or products Contact your authorized dealer for additional information 13 Warranty terms and conditions cannot be modified or extended by third parties without written approval of XMART Limited Warranty Xmart PRO11 If hardware product fail to work as warranted above the maximum liability of XMART under this limited warranty is expressly limited to the lesser of the price you have paid for the product or the cost of repairing or replacement of any hardware components that malfunction in conditions of normal use In no event will XMART be liable for any damages caused by the product or the failure of the product to perform including any lost profits or savings or special incidental or consequential damages XMART is not liable for any claim made by a third party or made by you for a third party XMART does not warrant that the operation of this product will be uninterrupted or error free XMART is not responsible for damage that occurs as a result of your failure to follow the instructions intended for this hardware product 120217_EN OPTIMA RACK 1K 3K 22 USER MANUAL USER MANUAL mart Optima Rack 1 3K mart Optima Rack 1 3K Quality Power Products Quality Powe
22. ty Power Products 4 Batteries Kit 2 Connect new batteries in series as indicated below 1 Remove batteries from plastic assembly 5 Using a DVM check battery assembly DC voltage is closet o 50 Vdc 4 x 12 5Vdc each If measured voltage is not correct probably there is a wrong connection Check correct and confirm 6 Batteries Kit 2 Connect new batteries in series as indicated below e 1 Remove batteries from plastic assembly voltage is not correct probably there is a wrong connection Check correct and confirm 120217_EN OPTIMA RACK 1K 3K 25 mart USER MANUAL Quality Power Products Optima Rack 1 3K 16 SPECIFICATIONS TABLE For Models 120Vac and 220Vac OPTIMA RACK UPS 1KVA 1 5KVA 2KVA 3KVA Capacity Capacidad 1100VA 800W 1700VA 1200W 2250VA 1600W 3400VA 2400W INPUT ENTRADA Range Rango Vac 100 load Range Rango Vac 50 load Frequency Range Rango de Frecuencia Power Factor Factor de Potencia Input Current T HDi T HDi de Corriente de Entrada OUTPUT SALIDA Voltage Output Voltaje de Salida AC Output Regulation Rango de Salida Frequency Frecuencia Batt Mode Current Crest Ratio Factor de Cresta Harmonic Distortion Dist Arm nica THD AC to Inverter Tiempo de AC a Inversor Waveform Forma de Onda EFFICIENCY EFICIENCIA ECO Mode AC Mode Modo AC BATTERIES BATERIAS Type Tipo Capacity Qty Capacidad Cantidad 120Vac
23. verload UPS output by connecting devices with higher power ratings than UPS power capacity Laser printers scanners and copiers frequently have two different power ratings in stand by power ratings are very low compared with consumption rating during operation If this kind of products will be connected to the UPS operation power rating must be considering to size total power consumption to be connected to UPS 4 EPO Function Emergency Power Off function allows to power off UPS outlets when EPO input is open When EPO port is closed EPO function is disable When EPO function is activated UPS will perform following actions Power Off all outlets Switch to STAND BY mode Acoustic alarm is activated as continuous beep d Warning message N 20 is indicated on LCD To disable EPO mode and recovering normal mode contact switch or jumper in EPO port must be closed and UPS must be powered On by selecting ON push button a b C EXTERNAL BATTERIES OPTION OPTIMA models with EX mark like OPTIMA 3K EX or OPTIMA RACK 3K EX are able to be connected to external battery cabinets EX BATT to offer longer backup times This kind of models has internal batteries as other OPTIMA models but they can also be connected at any moment to EX BATT supplied by XMART Special cables to connect EX BATT to UPS are supplied inside the box of EX BATT 120217_EN OPTIMA RACK 1K 3K 9 USER MANUAL mart Optima Rack 1 3K Quality Power Products 3 3
24. y conducted disturbances and signaling in public low voltage power supply systems EN 61000 4 6 2006 EN 61000 4 8 2001 EN 61000 4 11 2004 OPTIMA amp OPTIMA RACK 2KVA 3KVA Low Voltage Directive EN62040 1 1 2003 An Uninterruptible Power Systems UPS Part 1 1 General and Safety Requirement for UPS use operator access areas EMC Directives EN62040 2 2006 An Uninterruptible Power Systems UPS Part 2 Electromagnetic compatibility Class 2 EMC IEC 61000 4 2 2001 Electrostatic discharge immunity test IEC 61000 4 3 2006 Radiated radio frequency electromagnetic field immunity test IEC 61000 4 4 2004 Electrical fast transients Burst immunity test IEC 61000 4 5 2005 Surge immunity test IEC 61000 2 2 2002 Compatibility levels for low frequency conducted disturbances and signaling in public low voltage power supply systems EN 61000 4 6 2006 EN 61000 4 8 2001 EN 61000 4 11 2004 120217_EN OPTIMA RACK 1K 3K 3 USER MANUAL Optima Rack 1 3K 2 A PRODUCT DESCRIPTION REAR PANEL 220V EUROPE SCHUKO Outlets Programmable Outlets Standard Outlets AC Input Input Breaker Protected LAN network jacks EPO Emergency Power Off USB port RS 232 port Intelligent Slot for SNMP LAN cards Connector for External batteries EX models E e oa D OPTIMA RACK 1KVA 1 5K 2KVA 6 OD GID E 5 Eo Ao 3 10 8 4 OPTIMA RACK 3KVA 7 6 1 2 5 fe l 3 10 8 9 4 120217_EN OPTIMA RACK 1K 3K