KIMO User manual MP 200 Manometer

image

Contents

1. V General informations Maintenance KIMO performs calibration adjustment and maintenance of all your instruments to guarantee a constant level of quality of your measurements In regards of Quality insurance norms we recommend that the instruments are checked once a year KIMO Instruments have 1 year guarantee for any manufacturing defect return to our After Sales Service required for appraisal SEN Ruggh lzli 2 Tel 41 0 56 222 38 18 mailbox sentronic com MENTRONIC ac Produkte Support und Service CH 5453 Busslingen Fax 41 0 56 222 10 12 www sentronic com
2. 2 Tel 41 0 56 222 38 18 MENTRONIC ac Produkte Support und Service CH 5453 Busslingen Fax 41 0 56 222 10 12 mailbox sentronic com www sentronic com IV Menus 10 e Point point average This function allows to calculate the average value of various points that you can select Numbers of selected points and parameter for which calculation is carried out are displayed For adding a new measuring point to this calculation press OK to confirm If you click on average icon max and min values standard deviation average of each channel and e numbers of measuring points will be displayed If you want to see all values select Visu and scroll with A and V e Automatic average This function allows to calculate an average value that the device measured in an interval chosen time Timer is displayed Select Start with access key for launching measurement If you click on average icon max and min values standard deviation average of each channel and time chosen will be displayed e Automatic point point average This function allows to calculate the average value of various points calculated themselves on a duration beforehand defined You must enter duration click on the Period icon Select minutes or seconds with arrow buttons A and V Scroll digits with and V Confirm with OK The numbers of points is displayed Press Ok for launching measurement If you click on average icon max and min values standard deviation aver
3. A and V Confirm wih OK Parameters e Language Click on OK or to enter and a list of languages available appears Select language with arrow keys A and W and Confirm wih OK e Date time Click on OK or to enter into sub function Enter the day with A and V then move to the next digit with Repeat this operation for the month year hour and minute Confirm wih OK e Beep This sub function allows to enable or disable the keypad beep Click on OK or P to enter into the sub function Select respectively ON or OFF with A and V inorder to enable or disable the beep Confirm wih OK e Extinction This sub function allows to enable the automatic shut off and to select the delay in minute Click on OK or to enter into the sub function Select with A and V OFF in order to disable the automatic shut off or enter the delay from 15 to 120 minutes Confirm wih OK SEN Ruggh lzli 2 Tel 41 0 56 222 38 18 mailbox sentronic com MENTRONIC ac Produkte Support und Service CH 5453 Busslingen Fax 41 0 56 222 10 12 www sentronic com IV Menus e RF logging This sub function allows to enable or disable the RF Logging Click on OK or gt to enter into the sub function Select respectively ON or OFF with A and V inorder to enable or disable this function Confirm wih OK e Contrast This sub function allows to modify the contast Click on OK or to enter Select your contrast level from 0 to 9 or AUTO with A a
4. ac Produkte Support und Service CH 5453 Busslingen Fax 41 0 56 222 10 12 www sentronic com IV Menus e K2 factor Press or OK to enter into the K2 factor sub function Select respectively ON or OFF with A and W in order to enable or disable this function Confirm with OK e Units To select the unit press OK or P Select mm or in with arrow buttons A and VW Confirm with OK COmax The CO mode is available when a CO Temperature probe is connected You can access this function selecting COmax with the access key The CO is measured on an adjustable period the maximum value measured in this period is called CO max When CO peak is selected the period is diplayed 30 seconds by default Press Valid to launch the measurement When the countdown is finished the CO max is displayed To modify the period press Period with the access key Modify time with arrows keys A and V Confirm with OK or gt Gas e Connect the gas leak detection probe to the the AMI310 then turn on the AMI310 e Press button If the probe is connected for more than 1 minute measurement screen appears and indicates the concentration and places it on a bargraph If the probe has been just connected the screen indicates the remaining time of warm up then the measurement screen appears indicates the concentration and places it on a bargraph Several actions are possible during the measurement e Press to fix the mea
5. composed of several dated measuring points The operator can choose an automatic or a manual dataset with an instant value or an average This datasets can t be set using Datalogger 10 Software 1 1 Manual dataset Select name A manual dataset is composed of measuring points selected by the operator a Click on OK or to enter into sub function b Select Manual with A and V Confirm wih OK xf c Select Name with A and V Confirm wih OK or Enter dataset name with arrow keys PB and ay T A S J A V Confirm wih OK d For measurement launching click on OK with the access key The number of points selected and the parameter are displayed e To save your dataset click on Save with the access key 1 2 Automatic dataset An automatic dataset is composed of measuring points with interval of time a Click on OK or to enter sub function b Select Auto with A and W Confirm wih OK c Select Name with A and V Confirm wih OK or Enter dataset name with the arrow keys gt and A V Confirm wih OK d Enter dataset time and interval of time between 2 measurements by selecting Period with access key Select Duration or Interval with A and V Confirm wih OK Enter minutes and seconds with arrow keys amp and V from 1 minutes to 24 hours for the duration and from 5 seconds to 10 minutes for the interval Confirm with OK e Select Start for dataset launching Automatic dataset 2 Launch
6. ppm K From 200 to 1 300 C J From 100 to 750 C T From 200 to 400 C From 20 to 80 C From 0 to 200 ppm From 200 to 500 ppm 1 1 C or 0 4 Reading value 0 1 C 0 8 C or 0 4 Reading value 0 1 C 0 5 C or 0 4 Reading value 0 1 C 0 3 of reading 0 25 C 3 ppm 1 5 of reading 0 1 C 0 1 ppm ppm LEL VOL From 0 to 10 000 ppm 1 ppm GPL 0 1800 From 0 to 20 LEL From 0 to 1 VOL 20 of full scale at 20 C 65 HR 5 HR Di 0 01 LEL 0 001 VOL Al accuracies indicated in this document were stated in laboratory conditions and can be guaranteed for measurements carried out in the same conditions or carried out with required compensation The accuracy is expressed either by a deviation in C or by a percentage of the value concerned Only the bigger value is considered SENTRONIC 1c Ruggh lzli 2 CH 5453 Busslingen Tel 41 0 56 222 38 18 Fax 41 0 56 222 10 12 mailbox sentronic com E www sentronic com Il Introduction Top view Module connection mini Din C2 mini Din C1 connector connector Side view Power supply connection USB port for KIMO cable Elastomer grip Keypad Access keys for circular menu Browsing joystick e 4 directions e Validation Escape key On Off key SEN Ruggh lzli 2 Tel 41 0 56 222 38
7. use to obtain more precise results Click on OK or to enter into the sub function Select or signs with A and V with A and W then pass on the first digit with Enter the first digit then move to the next one with Confirm with OK e Select pressure system only available for Air velocity and Airflow functions Click on OK or to enter into sub function a list of pressure systems available appears Pitot tube L S Debimo or Other Select your system with A and V Confirm with OK If Other is selected you must enter a value Click on OK or to enter into sub function With A and enter the first digit then move to the next one with Confirm with OK e Solenoid valve available with the 500 Pa module Click on OK or to enter into the sub function Select respectively ON or OFF with A and W in order to enable or disable the solenoid valve function Confirm wih OK or When the solenoid valve is enabled it runs every minute SEN Ruggh lzli 2 Tel 41 0 56 222 38 18 mailbox sentronic com SENTRONIC ac Produkte Support und Service CH 5453 Busslingen Fax 41 0 56 222 10 12 www sentronic com IV Menus Recording The Recording menu allows a measurement dataset You can choose between a planned or a continuous dataset Memory capacity of the instrument is up to 8 000 points or 50 datasets 1 Create or launch a continuous dataset Select dataset A continuous dataset can be carried out using MP200 and is
8. 10 Iva El mse E E ie NPE oN SP ete een ener erent rene eee eee eee 10 Pressure system ans en 10 Solenoid Valve ee ee 10 Klee le DE 11 EE Dee 12 Be Ee enirar aeaa E a SEAE ee een 12 Fe Uu eee ee em ae 12 BEN ae ee ee 12 EEN 12 lg te e ln an fcc acc cnc ee ee 13 Contrast ee ec eer ar ee een 13 BR EE 13 tt 13 IR TEE 13 DOWNIOSGIHG Balkan nn ee ae nee 12 V General information 20000220000000n00000nnnnnnnunnnnnnnnnnnnnnnnnnnnnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnn 13 INTO agli eer ee 13 Vull null 14 ae Lg ne EE 14 SEN Ruggh lzli 2 Tel 41 0 56 222 38 18 mailbox sentronic com SENTRONIC ac Produkte Support und Service CH 5453 Busslingen Fax 41 0 56 222 10 12 www sentronic com A a Technical specifications Pressure module Technical features Piezoresistive sensor Overpressure allowed 500 Pa 250 mbar Overpressure allowed 2 500 Pa 500 mbar Overpressure allowed 10 000 Pa 1 200 mbar Overpressure allowed 500 mBar 2 bar Overpressure allowed 2 000 mBar 6 bar MP200 Connection See p 6 Housing ABS shock proof IP54 Keypad Metal coated 5 keypads 1 joystick Conformity Electromagnetic compatibility as per NF EN 61326 1 Power supply 4 alcalines batteries 1 5V LR6 Display Graphic display 128x128 pixels Dim 50 x 54 mm blue blacklit Ambient Neutra
9. 18 mailbox sentronic com MENTRONIC ac Produkte Support und Service CH 5453 Busslingen Fax 41 0 56 222 10 12 www sentronic com Il Introduction Connections amp D Interchangeable measurement module Interchangeable modules with Smart plus system are automatically recognized when connected to the instrument 1 Current Voltage module 3 Air velocity with Pitot tube Pressure module Pitot tupe optionnal It allows current or voltage measurements on V A1 or VA 2 channels with current voltage input cables or ammeter clamps Static Static PIE pressure PS PT 2 Pressure module Dynamic pressure PT PS It allows differential pressure air velocity or airflow measurements with Pitot tube or Debimo on two pressure inputs and and thermocouple temperature measurement on Tel channel with wire thermocouple probes equipped with a miniature male connector SS Wire probes with Smart plus system Wire probes with Smart plus system are automatically recognized when connected to the instrument CO temp probe is connected Sc on min DIN connectors C1 and or C2 mini Din C2 mini Din C1 connector connector Secured Mini Din Connector Retractable cable Ig 450 mm up to 2 4 m SEN Ruggh lzli 2 Tel 41 0 56 222 38 18 mailbox sentronic com MENTRONIC ac Produkte Support und Service CH 5453 Busslingen Fax 41 0 56 222 10 12 www sentronic com lll Browsing
10. D _ Power up 7 7 ________ Enter code 0000 Homepage display ton je Probe Leen Y Probe connection Probe display T 22222222222 Return to previous screen ios j Messung Garam Measurement PRESSURE Displa AIRFLOW display Enter key code with directional pad if the locking is activated lt gt ad AV Select asub menu with access keys or with arrow keys lt gt Select a connection with right and left keys lt gt Connections can be activated or deactivated with A or V Select a sub function with access keys or with arrow keys lt gt Select a sub function with access keys or with arrow keys lt gt Rec e Probe Hold 4 ConfigsAutoZ t Alarms 4 ParamesmAirflows Veloci Avg en Hold 4 Config AutoZ Rec Probe Hold Cong AZ Alarms Params Veloci lt Pressl lt Area Alarms Params Airflow Presse Avg i Communication interrupted Ruggh lzli 2 CH 5453 Busslingen SENTRONIC 1c Tel 41 0 56 222 38 18 Fax 41 0 56 222 10 12 Check probes connection mailbox sentronic com www sentronic com IV Menus Probe menu Wire probes and modules with Smart plus system are automatically recognized from first connecti
11. KIMO INSTRUMENTS Pressure Temperature Humidity Air velocity Airflow Sound level MP 200 Manometer Supplied Wserzliiejgzinieia K certificate MP 200 SEN Ruggh lzli 2 Tel 41 0 56 222 38 18 mailbox sentronic com VYENTRONIC ac Produkte Support und Service CH 5453 Busslingen Fax 41 0 56 222 10 12 www sentronic com SEN Ruggh lzli 2 Tel 41 0 56 222 38 18 mailbox sentronic com SENTRONIC ac Produkte Support und Service CH 5453 Busslingen Fax 41 0 56 222 10 12 www sentronic com Table of contents Technical specifications u 2u420220202002020220000nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 4 TECHNICAL TEA Ur ES ern 4 BWP ITN AGN EE 4 Tei ei ee ei ee e DEE 5 RI e de E d Connec ONS eee 6 IER ie Cu DEE 7 IV TE TT ee aaa arena E 8 PTODE rn in 1 EE S F NEEIONS urn ns e saz se teencaepennecsceneese tay esce cue edecnscesoceseasuxnseoasguscesacvsscesausaseaeessentaasasnxnaescaeeeeusanaseseespeaeeeseaanes S PS Kl acacia ssc es accross toc ee S ANHO ee ee een S PES E 8 RU 8 TEE 8 REIF TE 9 Ru ee ON ne nO ee Te eo Ta a nT eNO ne en 9 EN E D ET 9 Ar le CIGN nee 9 Fold NID MaX on eee 9 AVETE ee ee ee ee 9 Point point average een eu 10 Automatic average anne 10 Automatic point point average 10 Connor ratia sin E a eee eee eee eee 10 ThermocaupleWVpe nenne ee 10 RI e ee ee E E een 10 GU E REINER BIER cee cleantech nee A cee 10 uge 0 E
12. a planned dataset A planned dataset is composed of several locations For each location the operator can enter a theorical value and a tolerance for the parameter to be controlled Planification must be made via the software a Click on OK or to enter into sub function b Select Planned with A and W Confirm wih OK c Choose dataset name with A and V Confirm wih OK d Select the location with A and W Confirm wih OK SEN Ruggh lzli 2 Tel 41 0 56 222 38 18 mailbox sentronic com MENTRONIC ac Produkte Support und Service CH 5453 Busslingen Fax 41 0 56 222 10 12 www sentronic com IV Menus 3 Preview of tables of points of datasets Dataset summary You can display tables of points of datasets performed on the device a Go to Recording menu b Select Display Click on OK to validate c Select dataset name with arrow keys A et V Click on OK to validate Summary screen of selected dataset is displayed From this screen you can e Select other dataset using arrow keys lt and P e Display data of other channels using arrow keys A and V d Click on Mesure to display values table of selected dataset Dataset table From this screen you can 2 Ee SC e Browse values table of points of the same channel pressing Prev or Next e e Change of channel with arrow keys lt and gt e Back to dataset summary screen pressing Visu 4 Delete all datasets Select Delete with
13. age of each channel and numbers of measuring points will be displayed You can view each measuring points if you click on Visu Configuration A If you use thermocouple probes you must enter type into the Configuration sub function Configuration sub function allows to e Select thermocouple type Click on OK or to enter into sub function a list of thermocouple available K J or T type appears Select type with A and V Confirm with OK e Select display Use the arrow key or click on OK to enter into sub function Select channel using A and W then confirm with OK Use A or W to select ON displayed or OFF not displayed then confirm with OK e Select units Click on OK or to enter into sub function a list of units available appears Select unit required with A and V Confirm with OK Click on Esc to return to previous screen e Select integration The coefficient of integration allows to smooth the measure to avoid variations Click on OK or to enter into sub function a list of coefficient From 0 to 9 appears Select coefficient required with A and V Confirm with OK Coefficient 0 no integration important fluctuation in the shown measure Select compensation It is possible to modify the value of the compensation in temperature Indeed the velocity and the airflow with Pitot s tube and with Debimo blades are calculated from a temperature of use in 20 C It is thus necessary to enter the real temperature of
14. calibration is performed by disconnecting the two pressure inlets of the sensor then by pressing Autoz key AIRFLOW Access Airflow function by means of Airflow key With Airflow function you can access to following sub functions Hold see Air velocity Area Config Configuration see Air velocity Params Parameters see Air velocity Avg Average see Air velocity Rec Recording see Air velocity AIRFLOW display Area e Duct type To select vent Type press OK or P Rec Probe Hold w Config Autoz Select Lx W or Diam or K factor with arrow buttons A and V Confirm with OK If K factor is s Alarms4 Params Veloci Pressa Areas selected you must enter value You can choose a K factor already registered by selecting with 4 and V Confirm with OK This factor can be modified by selecting with A and V then confirm with OK or Select Modify with OK or Enter factor by means of arrow keys A and V Confirm with OK or gt e Sizes Press or OK to enter into sizes sub function You can choose an air vent already registered by selecting it with arrow keys A and V Confirm with OK or This air vent can be modified by selecting it with arrows keys A and W then Confirm with OK or Select Modify with OK or Enter sizes by means of arrow keys A and W Confirm with OK or P SEN Ruggh lzli 2 Tel 41 0 56 222 38 18 mailbox sentronic com MENTRONIC
15. l gas Operating temp from 0 to 50 C Storage temp from 20 to 80 C Auto shut off adjustable from 0 to 120 min Weigpht 340g Languages French english Display of 6 measurements including 4 simultaneously lt Measuring units Measuring range Pa mmH O In WG mbar hPa mmHg DaPa kPa bar PSI From 0 to 500 Pa From 0 to 2 500 Pa From 0 to 10 000 Pa From 0 to 500 mbar From 0 to 2 000 mbar Accuracy Resolutions 100 Pa 0 2 of reading 0 8Pa 0 1 Pa from 100 to 100 Pa beyond 0 2 of reading 1 5Pa 1 Pa beyond 0 2 of reading 2Pa 1Pa 0 2 of reading 10Pa 1Pa 0 2 of reading 0 5mbar 0 1mbar 0 2 of reading 2mbar imbar PITOT TUBE Air velocity m s fpm Km h mph From 2 to 5 m s 0 3 m s 0 1 m s From 5 1 to 100 m s 0 5 of reading 0 2m s 0 1 m s N Airflow m h cfm I s m s From 0 to 99 999m h 0 2 of reading 1 PE 1 m h DEBIMO BLADES s ot et Air velocity m s fom Km h mph Airflow m h cfm Us m3 s From 4 to 20 m s From 21 to 100 m s From 0 to 99 999m h 0 3 m s 0 1 m s 1 of reading 0 1m s 0 1 m s 0 2 of reading 1 PE 1 m h CURRENT VOLTAGE V mA From 0 to 2 5 V From 0 to 10 V From 0 to 4 20 mA 2mV 0 001 V 10mV 0 01 V 0 01mA 0 01 mA THERMOCOUPLE See related datasheet C OI e er d CO Temperature Temp Se F GE CO
16. nd V Confirm wih OK e Backlit This sub function allows to modify the backlit Click on OK or to enter Select your backlit level from 0 to 9 or AUTO with A and V Confirm wih OK If you select AUTO the MP200 adjuts automatically the backlit according to the room brightness e Key locking This sub function allows to enable or disable the key lock Click on OK or to enter into sub function Select respectively ON or OFF with A and V inorder to enable or disable this function Confirm wih OK If the locking is enabled the code menu appears e Code This sub function allows to enter the security code Click on OK or and the code appears Enter the first digit of the code with A and V then move to the next one with Confirm wih OK Downloading data see DataLogger 10 user manual chapter Ill Read device page 6 V General informations Info menu This menu allows to view the serial number of instrument and firmware version When battery indicator flashes it is recommended to change the batteries 1 Remove the front part at the back of the instrument 2 Remove batteries 3 Insert new batteries AA LR6 1 5V in accordance with proprer polarity drew inside the housing 4 Replace the front SEN Ruggh lzli 2 Tel 41 0 56 222 38 18 mailbox sentronic com VYENTRONIC ac Produkte Support und Service CH 5453 Busslingen Fax 41 0 56 222 10 12 www sentronic com
17. on The Probe menu only appears when probes or module are connected This menu allows to view probe Probe display information plugged to C2 Module C1 or wireless connections See Connections p 6 for more information about connections Available information are e Sensor type Serial number Date of last calibration or adjustement Probes Status enabled ou disabled On enabled mode the probe is connected the measurement is carried out and the value is displayed On disabled mode the probe is connected the measurement is not carried out and the value is not displayed ORERE Pressure Access Pressure function by means of key With Pressure function you can access to following sub functions Hold see Air velocity Config Configuration see Air velocity Params Parameters see Air velocity Avg Average see Air velocity Rec Recording see Air velocity Rec Probe Hold Config AutoZ Alarms gt ParamAirflow Veloci Avg AutoZ This sub function allows to compensate for any long term drifts of the sensing element by a manual adjustment of the zero For the 500 Pa measurement module self calibration is performed by the solenoid valve Once pressing Autoz key the zero is readjusted This function can also be automatically performed by using the solenoid valve function For others measurement modules self
18. surement When the measurement is fixed press to access to maximum and minimum values of the measurement From this screen press to back to measurement e Press to modify alarm threshold Use the arrows to modifiy the threshold value then press to validate alarm threshold and back to measurement screen Alarm threshold corresponds to the right value on the bargraph The beep repetition frequency will increase accordong to the increase of detected gas concentration and the display will blink at the same frequency e During the measurement follow the path of the gas pipe to controle placing the probe on the pipe Air velocity GAS DISPLAY Alarm threshold Access Air velocity function by means of key With Air velocity function you can access to following sub functions Hold Config Configuration Params Parameters Avg Average Rec Recording Hold Min Max Press 1x in order to select HOLD function measurement holding on display Press 2x in order to select Min Max function display of minimum and maximum values Press 3x back to the continuous measurement Average Display AIR VELOCITY Rec Probe sp Hold ConfigAutoZ Alarme tParamgetAirfiow jk Press3 Avg Press or OK to enter Average sub function With A and V you can select point point average auto point point automatic Confirm with OK or SEN Ruggh lzli

Download Pdf Manuals

image

Related Search

Related Contents

Owner`s Manual & Safety Instructions  Z-Wave Aeon Labs Inline Smart Energy - Iluminator  Nokia 808 PureView Bedienungsanleitung  Lb. per sq. ft = abrév. de pound per square  PLASTER / MORTAR MIXERS  DIRETORIA DE PATENTES - Revista da Propriedade Industrial  EtherCAT Feldbusknoten NA9286  SortMeRNA User Manual - Bioinformatics Software Server    