Home
Z-Wave Aeon Labs Inline Smart Energy - Iluminator
Contents
1. Generic Device Class Multilevel Switch Specific Device Class Multilevel Power Switch Routing Yes FLIRS No Firmware Version 1 24 Explanation of Z Wave specific terms e Controller is a Z Wave device with capabilities to manage the network Controllers are typically Gateways Remote Controls or battery operated wall controllers e Slave is a Z Wave device without capabilities to manage the network Slaves can be sensors actuators and even remote controls e Primary Controller is the central organizer of the network It must be a controller There can be only one primary controller in a Z Wave network e Inclusion is the process of bringing new Z Wave devices into a network e Exclusion is the process of removing Z Wave devices from the network e Association is a control relationship between a controlling device and a controlled device e Wakeup Notification is a special wireless message issued by a Z Wave device to announces that is able to communicate e Node Information Frame is a special wireless message issued by a Z Wave device to announce its capabilities and functions Disposal Guidelines The product does not contain hazardous chemicals Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps haza
2. the devices of this network This process is called Inclusion Devices can also leave a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller will be turned into exclusion respective inclusion mode Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode Only if the primary controller is in inclusion or exclusion mode this device can join or leave the network Leaving the network i e being excluded sets the device back to factory default If the device already belongs to a network follow the exclusion process before including it in your network Otherwise inclusion of this device will fail If the controller being included was a primary controller it has to be reset first To include the Aeon Labs Inline Smart Energy Illuminator with your Z Wave controller simple bring it in the inclusion mode and c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany www zwaveeurope com Cawove click the Inclusion Exclusion button at the Aeon Labs Inline Smart Energy Illuminator once If the Aeon Labs Micro Inline Smart Energy Illuminator was successfully included to a Z Wave network the Status Indication LED will either be solid on or off depending on if the switch is on or off after the button was last pressed Operating the device The dimmer is operated by the local switch button or wi
3. the total time the device need to blink The value if set in seconds The MSB defines the on off interval of the blinking The unit is 0 1 s Value Description 0 65535 Configuration Bytes Default 0 Notification on Status Change Parameter Number 80 Parameter Size 1 Defines the automated status notification of an associated device when status changes Disables Function of automated sending of a Report triggered by minimal change of value Parameter Number 90 Parameter Size 1 Value Description 0 Disabled Default 1 Enabled Minimum Change to send Report Watt Parameter Number 91 Parameter Size 2 The value represents the minimum change in Wattage for a Report to be sent Value Description 0 32000 W Default 50 Minimum Change to send Report Parameter Number 92 Parameter Size 1 The value represents the minimum change in Watage Percent for a report to be sent Description Default 10 Report type send in Reporting Group 1 Parameter Number 101 Parameter Size 4 Defines the type of report sent for the Reporting Group 1 Value Description 2 MultiSensor Report 4 Meter Report for Watt 8 Meter Report for kWh Default 4 c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany www zwaveeurope com lowa Report Type send in Reporting Group 2 Parameter Number 102 Parameter Size 4 Defines the type of report sent for the Reporting Group 2 Value Descripti
4. Cawove Ei AEO SEI EU Inline Smart Energy Illuminator Firmware Version 1 24 Quick Start M This is a Z Wave actuator Inclusion and Exclusion are confirmed by a single click on the button If the Aeon Labs Inline Smart Energy Illuminator is not included into any Z Wave network the LED will be blinking continually Please refer to the chapters below for detailed information about all aspects of the products usage What is Z Wave This device is equipped with wireless communication complying to the Z Wave standard Z Wave is the international standard for wireless communication in smart homes and buildings It is using the frequency of 868 42 MHz to realize a very stable and secure communication Each message is reconfirmed two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Controllers are either static mains powered controllers C also referred to as gateways or mobile battery operated remote controls R This results in a number of possible communication patterns within a Z Wave network that are partly or completely supported by a specific device 0 00 N N OS Controllers control actuators Actuators report change of statu
5. ed association In order to control a different device the controlling device needs to maintain a list of devices that will receive controlling commands These lists are called association groups and they are always related to certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will receive a common wireless command Association Groups 1 Status Reports max nodes in group 5 Configuration Parameters Z Wave products are supposed to work out of the box after inclusion however certain configuration can adapt the function better to user needs or unlock further enhanced features IMPORTANT Controllers may only allow configuring signed values In order to set values in the range 128 255 the value sent in the application shall be the desired value minus 256 For example to set a parameter to 200 it may be needed to set a value of 200 minus 256 minus 56 In case of a two byte value the same logic applies Values greater than 32768 may needed to be given as negative values too Type of Sensor Report Parameter Number 1 Parameter Size 1 Defines the value type to be sent as Sensor Report c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany www zwaveeurope com lowe Value Description 0 Power Default 1 Voltage Blinking Behavior Parameter Number 2 Parameter Size 2 This is a double byte value The LSB defines
6. g status Before Device is installed Please read carefully the enclosed user manual before installation of the radio actuator in order to ensure an error free functioning ATTENTION only authorized technicians under consideration of the country specific installation guidelines norms may do works with 230 Volt mains power Prior to the assembly of the product the voltage network has to be switched off and ensured against re switching The product is permitted only for proper use as specified in the user manual Any kind of guarantee claim has to be forfeited if changes modifications or painting are undertaken The product must be checked for damages immediately after unpacking In the case of damages the product must not be operated in any case If a danger free operation of the equipment cannot be assured the voltage supply has to be interrupted immediately and the equipment has to be protected from unintended operation Installation Guidelines Button The Aeon Labs Inline Smart Energy Illuminator can be plugged between every Standard Schuko wall outlet and the electrical appliance with maximum load of 625W To switch the plugged device on or off simply push the local button once or use a Z Wave Controller The status is shown by the status LED at the device Behavior within the Z Wave network On factory default the device does not belong to any Z Wave network The device needs to join an existing wireless network to communicate with
7. on 2 MultiSensor Report 4 Meter Report for Watt 8 Meter Report for kWh Report Type send in Reporting Group 3 Parameter Number 103 Parameter Size 4 Defines the type of report sent for the Reporting Group 3 Value Description 2 MultiSensor Report 4 Meter Report for Watt 8 Meter Report for kWh Send Interval for Reporting Group 1 Parameter Number 111 Parameter Size 4 Defines the time interval when the defined report of Reporting Group 1 is sent out Value Description 0 65535 Interval Default 720 Send Interval for Reporting Group 2 Parameter Number 112 Parameter Size 4 Defines the time interval when the defined report of Reporting Group 2 is sent out Value Description 0 65535 Interval Default 720 Send Interval for Reporting Group 3 Parameter Number 113 Parameter Size 4 Defines the time interval when the defined report of Reporting Group 3 is sent out Value Description 0 32000 Interval Command Classes Supported Command Classes e Basic version 1 e Association version 1 e Multilevel Switch version 1 e All Switch version 1 e Meter version 2 e Configuration version 1 e Multilevel Sensor version 3 e Manufacturer Specific version 1 e Version version 1 c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany www zwaveeurope com lowa Technical Data Explorer Frame Support No SDK 5 02 pl3 Device Type Slave with routing capabilities
8. rdous substances can leak into the groundwater and get into the food chain damaging your health and well being 6 c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany www zwaveeurope com
9. reless via Z Wave A single click switches the device on or off To have the dimming function simple hold the button pushed until your desired level The Aeon Labs Inline Smart Energy Illuminator can report wattage energy usage or kWh energy usage to a Z Wave gateway or controller when requested If this function is supported by the gateway controller the energy consumption will be displayed in the user interface of the gateway controller Please consult the operation manual for these gateways controllers for specific instructions Node Information Frame NIF The Node Information Frame is the business card of a Z Wave device It contains information about the device type and the technical capabilities The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame Beside this it may be needed for certain network operations to send out a Node Information Frame A single click at the Inclusion Exclusion switch sends a Node Information Frame LED Control e The LED on the Micro Smart Energy Illuminator will blink if it is currently not paired into a Z Wave network e If the Aeon Labs Inline Smart Energy Illuminator was successfully included to a Z Wave network the Status Indication LED will either be solid on or off depending on if the switch is on or off after the button was pressed Associations A Z Wave devices control other Z Wave devices The relationship between one device controlling another device is call
10. s back to controller Sensors report change of status of measured values to controller Sensors directly control actuators Actuators control other actuators Remote controls send signals to static controllers to trigger scenes or other actions Remote controls control other actuators NOU BWYN FE There are two different role a controller can have There is always one single primary controller that is managing the network and including excluding devices The controller may have other functions like control buttons as well All other controllers don t manage the network itself but can control other devices They are called secondary controllers The image also shows that its not possible to operate a sensor just from a remote control Sensors only communicate with static controllers c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany www zwaveeurope com lowa Product description The Aeon Labs Inline Smart Energy Illuminator is a Z Wave light dimmer specifically used to enable Z Wave commands and control on off dim a device that is connected to a standard Schuko Wall Outlet It can also report immediate wattage consumption or kWh energy usage over a period of time The wireless module is powered from the mains supply and is a three wire design which requires a neutral connection In the event of power failure non volatile memory retains all programmed information relating to the units operatin
Download Pdf Manuals
Related Search
Related Contents
接続する前に 接続する OCZ Technology Sabre OLED Keyboard グリーンパワー電磁開閉器 自動スターデルタ形 8M3546003 Manuel d`utilisation Insignia NS-PDP42 User's Manual VF-Blaster 2.0 Manuel de maintenance - SMA Solar Technology AG Guia do usuário da impressora a laser Phaser 4510 Star Micronics PW2000-24 User's Manual 耳又扱説明書 - サンケン電気 Copyright © All rights reserved.
Failed to retrieve file