Home
User Manual - partirentournee
Contents
1. 1 5 Lamp Specifications ccsveessesesiesvsscenssasssseevtcseccorenssecorsneseaseevseooeveus cad aeisedeedanteass 1 5 Cabling and Terminator Specifications 1 5 Optional Accessories ist ins nr ne ee 1 6 Chapter 2 Setup and Configuration Unpacking th Products sienien nore e ddl a entente lente teste 2 1 Installing a Power Cord Cap 2 1 Installing a Line Cord Cap U K Only 2 2 Vatic Fitter Heads Information Danmark 2 2 Installing the Lamp in ColorCommand ss 2 2 NAAA an REER nee er ue so 2 4 Linking the 10 22 5000 SIG 2 4 Setting up the link Mn nn nero a on 2 6 Mounting the Fixtures E E E OD SSR Sa serende s 2 6 Powering On the Fixture irena ae RTS aaa 2 8 Connecting ColorCommand to Power 2 8 Homing Coloreomm nd u en ein ri 2 9 Assigning a DMX Start Channel ss 2 9 Assigning a DMX Start Channel to ColorPower ss 2 9 Manually Assigning a DMX Start Channel 2 10 Automatically Assigning a DMX Start Channel 2 11 Verifying and Uploading ColorPower Software 2 12 Fixture Maintenance anne 2 13 Cleaning the ColorCommand Lens 2 13 Replacing the ColorCommand Lamp eee nere erne rn sn er nnnnnee 2 13 Maintenance MOd6 2 13 ColorPower User Manual ix Chapter 3 Fixture Operation Accessing the Menu System nsen nennen 3 1 Basic Navigation sanere edru nr Mere ren sten 3 1 MEHWOPLONS MH engeren drain sonne needs een eder 3 2
2. so the color you create during rehearsals is the same color you will see a week month or year later There are no gel scrolls to burn out or replace and ColorCommand can be used anywhere you would currently use a PAR can Fresnel or PC ColorCommand Features e Philips Halogen Biplanar 750W or 800W lamp e 87 13 adjustable beam angle e 18 32 field angle e 270 tilt e 1 meter minimum focus distance e Lamp relay to automatically shut off the lamp if the power is disconnected or the cable is removed Compact and lightweight similar in size to a PAR can e Efficient optics with high output Fat output beam 8 inches 200 mm in diameter e Smooth color mixing including pastel and saturated colors e Fully dichroic colors that never fade Full control over color mixing from smooth stepless movement allowing slow imperceptible color fades to rapid snap color changes Quiet performance even during snap color changes Even soft edged wash with good beam distribution for easy blending ColorPower User Manual Features and Specifications 1 3 e Live color fading from one color to another at any speed with no strange intermediate colors Integral fully variable beam angle Incandescent lamp allowing color temperature 3200K matches with other incandescent fixtures e Very little light spill e Fits accessories such as barn doors top hats and snoots e Operates on 4 DMX channels Yellow Magenta
3. 58h 5Fh Home Unit 3 96 103 38 40 60h 67h 1 CONTROL Home Unit 4 104 111 41 44 68h 6Fh Home Unit 5 112 119 44 47 70h 77h Home Unit 6 120 127 47 50 78h 7Fh Home Unit 7 128 135 50 53 80h 87h Home Unit 8 136 143 53 56 88h 8Fh Home Unit 9 144 151 57 60 90h 97h Home Unit A 152 159 60 62 98h 9Fh Home Unit B 160 167 63 66 AOh A7h Home Unit C 168 175 66 69 A8h AFh Home Unit D 176 183 69 72 BOh B7h Home Unit E 184 191 72 75 B8h BFh Home Unit F 192 199 75 78 COh C7h Reserved 200 255 78 100 C8h FFh ColorCommand DMX Protocol Table Chan Parameter Description i 7 a 1 Cyan Cyan 0 open 255 fully saturated 0 255 0 100 00 FF 2 Magenta Magenta 0 open 255 fully saturated 0 255 0 100 00 FF 3 Yellow Yellow 0 open 255 fully saturated 0 255 0 100 00 FF 4 Beam Angle Beam Angle 0 narrow 255 wide 0 255 0 100 00 FF ColorPower User Manual Fixture Operation 3 5 3 6 Fixture Operation ColorPower User Manual Appendix A Important Safety Information Warning For Continued Protection Against Fire 1 This equipment ColorCommand M is designed for use with a Philips 134205 750W 134213 800W lamp only Use of any other type lamp may be hazardous and may void the warranty Do not mount on a flammable surface Maintain minimum distance of 3 meter 0 98 foot from combustible materials Replace fuses only with the specified type and rating This equipm
4. DMX Mets ol MALE MON A eE a e dt te metre 3 2 Information INFO Menu een orata 3 2 Display the Software Version VERS 3 2 Display the Unit Information UNIT ss 3 2 Control CTRL Menti asian RER ERI ai 3 3 Reset and Home RST 3 3 ColorP wer Menu Map riniciia ila la iaia la se nn Hs 3 3 DMX is cd s stects css is cds 3 4 Basics of DMX 00 3 4 DM 010001008 3 4 Homing the Fixture Using a DMX Controller 3 4 ColorPower DMX Protocol Table ss 3 5 ColorCommand DMX Protocol Table 3 5 Appendix A Important Safety Information List of Figures ColorPower Physical Dimensions nan naranncnnnas 1 2 ColorCommand Physical Dimensions i 1 4 Removing thelamp ni Ip po Does 2 3 Installing the lampe Be RSR nad 2 3 Rotary Sswilch 0 2 4 Sample rotary switch settings on a link 2 4 Dichroic Theatre Series linking diagram ss 2 5 ColorPower menu navigation buttons ss 2 10 Sample manual assignment of DMX start channels 2 11 Sample automatic assignment of DMX start channels 2 12 ColorPower Menu display panel 3 1 x ColorPower User Manual Chapter 1 Features and Specifications Overview This manual includes information for the ColorPower power supply and the ColorCommand fixture These are the first o
5. Up gt and lt Down gt arrow buttons scroll to the C7AL menu and press the lt Enter gt button to select 3 Using the lt Up gt and lt Down gt arrow buttons scroll to the AST option and press the lt Enter gt button to select ColorPower will reset and home all connected units ColorPower Menu Map Level 1 Level 2 Level 3 Level 4 Level 5 Options Description Set DMX Start channel number for Color ADDR 1 512 Power hub 001 512 AUTO DONE Sets automatic start channel selection for DMX attached modules MODE 1XX Sets manual start channel selection for MANU UNIT 12xx 11 512 attached modules DISC DONE Maintenance mode VERS V R H Displays version Major Minor Build INFO UNIT 1XX Displays rotary switch setting and type of 12XX unit connected to the fixture link Resets ColorPower and homes all CTRL RST connected units ColorPower User Manual Fixture Operation 3 3 DMX Programming Basics of DMX Control A Parameter is a fixture attribute that can be controlled to modify the light beam in terms of color beam quality and pattern intensity or focus position DMX programming assigns a DMX value to each of the fixture s parameters A Cue sometimes referred to as a look or a scene is one combination of parameter settings Cues are combined and timing is added to create shows DMX Protocol Programming a fixture for a DMX link requires each p
6. and tighten the thumbscrews Caution Improperly installed lamps cause premature lamp failure and socket problems Make sure the lamp socket wires are not wrapped around the lamp or trapped while reinserting the lamp assembly ColorPower User Manual Setup and Configuration 2 3 Unit Addressing A rotary switch is located on the back of each ColorCommand fixture see Figure 2 3 You must select a rotary switch setting for each fixture in the link The fixture s rotary switch setting determines the fixture s unit address which identifies the fixture s unique position in the link The rotary switch allows up to 16 possible settings 0 9 de Figure 2 3 Rotary switch Warning You must set the rotary switch to a unique number for each fixture on a fixture link For example if you have 12 fixtures on a link you might set the rotary switch on the first fixture to 0 the second fixture to 1 the tenth fixture to 9 the eleventh fixture to A and so on You can choose any order for fixtures on a link and any rotary switch setting for a fixture as long as each fixture in the link is assigned a unique number see Figure 2 4 DMX Control Desk Rotary Switch Settings Figure 2 4 Sample Rotary switch settings Linking the Fixtures A single ColorPower can control up to 12 ColorCommand fixtures six fixtures per output ColorPower Connection to any other manufacturer s power 1 Caution Color
7. gesch tzt werden Servicearbeiten sollten nur von Fachpersonal ausgef hrt werden Das Ger t enth lt keine wartungsbed rftigen Teile Dieses Ger t geh rt zur Klasse I Dieses Ger t mu geerdet werden Warnung Zum Schutz Gegen berm ssige Ultraviolett UV Bestrahlung 1 3 Benutzen Sie dieses Ger t nur wenn das komplette Lampengeh use fest eingebaut ist ebenfalls d rfen keine der Schutzabdeckungen Linsen oder der UV Schutz Besch digungen aufweisen Die Schutzabdeckungen Linsen und der UV Schutz m ssen ausgewechselt werden wenn sie sichtlich derma en besch digt sind da sie ihre Wirksamkeit einb en z B infolge von Rissen oder tiefen Kratzern Nie direkt in die eingeschaltete Lampe schauen Warnung Zum Schutz Vor Verletzungen 1 2 Verwenden Sie bei der Installation des Beleuchtungsk rpers ein zus tzliches Sicherheitskabel VORSICHT Bei einer hei e Lampe besteht Explosionsgefahr Nach dem Abschalten der Netzspannung sollten Sie etwa 5 Minuten warten bevor Sie das Lampengeh use ffnen Sch tzen Sie beim Auswechseln der Lampen Ihre H nde und tragen Sie eine Schutzbrille Die Oberfl chen des Ger tes k nnen Temperaturen bis zu 100 C erreichen Vor dem Anfassen stets 5 Minuten lang abk hlen lassen Falls die Lampe besch digt oder durch W rmeeinwirkung verformt ist mu sie ausgewechselt werden ColorPower User Manual Important Safety Information A 3 Ap ndice A Informaci
8. is damage notify both the shipping agent and the sales agent immediately Save the shipping carton and packing materials The carton and packing materials are specifically designed to protect the product during transport High End Systems assumes no responsibility for products that are damaged during transport Return a product for repair in its original shipping carton and packing materials Before returning anything to the factory call your High End Systems dealer distributor for a Return Material Authorization RMA number The factory cannot accept any goods shipped without an RMA number Installing a Power Cord Cap ColorPower ships with a power cord with a Standard NEMA 5 15 cord cap ColorCommand ships with a power cord without a cord cap Different locations even within the same country may require a different power cord cap to connect the fixture to a power outlet Because of the variety of power cord caps used worldwide High End Systems Inc cannot make specific recommendations for the power cord cap ColorPower User Manual Setup and Configuration 2 1 Contact a local authority for the type of power cord cap needed When installing the power cord cap note that the cores in the mains lead are colored in accordance with the following code e green and yellow earth blue neutral brown live AN Warning Class 1 equipment This equipment must be earthed Installing a Line Cord Cap U K Only In the Unite
9. n Importante De Seguridad Advertencia Para Protecci n Continua Contra Incendios 1 He Co BO Este equipo ColorCommand est dise ado para utilizarse nicamente con la l mpara Philips 134205 750W 134213 800W El uso de cualquier otro tipo de l mpara pued resultar peligroso y pued anular la garant a No monte el equipo sobre una superficie inflamable Mantenga una distancia m nima de materiales combustibles de 0 3 metro Cambie los fusibles nicamente por otros que sean del tipo y la clasificaci n especificadas Este equipo debe conectarse a un circuito que tenga una protecci n m xima contra una sobrecargas de 20 A Advertencia Para La Protecci n Continua Contra Electrocuciones 1 4 5 Si se recibi este equipo sin el conector de alimentacion monte usted el conector correcto seg n ia clave siguente e moreno vivo e azul neutral e verde amarillo tierra Desconecte el suministro de energia antes de cambiar l mparas o prestar servicio de reparaci n Este equipo esta disenado para usarce en lugares secos no lo exponga a la lluvia o humedad Derive el servicio de reparaci n de este equipo al personal calificado El interior no contiene repuestos que puedan ser reparados por el usuario Equipo de Clase I Este equipo debe conectarse a tierra Advertencia Para Protecci n Continua Contra La Exposici n A Radiaci n Ultravioleta UV Excesiva 1 2 3 No opere este eq
10. of the outer holes on the yoke Use two locking washers per clamp when attaching the clamp to the yoke Use two people to mount each fixture one person to hold the fixture while it is being secured in place and one person to secure the fixture to its support and to attach clamps and safety cables ColorPower User Manual Setup and Configuration 2 7 Always stand on a firm stable surface when mounting a fixture to its support The fixture should be at a height where you can comfortably work on it and should either be resting on a stable surface or held in a stable manner e Tighten the clamp s firmly to the yoke and to the support Loop one or more suitable safety cables around the support and the yoke Caution After mounting the fixtures inspect all connected cables to ensure that the cables are properly routed away from any hot surface Do not mount ColorPower above or next to a hot fixture closer than I ft 3 m Powering On the Fixture A Caution Do not power on the fixture until verifying that the line cord cap is suitable for the power source in your location Warning This equipment for connection to a branch circuit having a maximum overload protection of 20 A Before powering on ColorPower or ColorCommand fixtures connected to ColorPower complete the following e Make sure the lamp is installed as described in Installing the Lamp in ColorCommand on page 2 2 Make sure the appropriate power c
11. or ultraviolet screens if they have become visibly damaged to such an extent that their effectiveness is impaired for example by cracks or deep scratches 3 Never look directly at the lamp while lamp is on Warning For Continued Protection Against Injury To Persons 1 Use secondary safety cable when mounting this fixture 2 Caution hot lamp may be an explosion hazard Do not open for 5 minutes after switching off Wear eye and hand protection when re lamping 3 Equipment surfaces may reach temperatures up to 100 C 212 F Allow 5 minutes for cooling before handling 4 Change the lamp if it becomes damaged or thermally deformed SU OD ColorPower User Manual Important Safety Information A 1 Appendice A Importantes Informations Sur La S curit Mise En Garde Pour Une Protection Permanente Contre Les Incendies 1 Cet appareil ColorCcommand est con u uniquement pour une lampe Philips 134205 750W 134213 800W Son utilisation avec tout autre type de lampe peut tre dangereuse et annuler la garantie 2 Ne pas monter les lampes sur une surface inflammable 3 Maintenir une distance minimum de 0 3 m tre de mati res inflammables 4 Ne remplacer les fusibles qu avec des mod les et valeurs assign es recommand s 5 Cet appareil de connection au circuit comporte une protection contre les surcharges de 20 A M 1 ise En Garde Pour Une Protection Permanente Contre Les Chocs Electriques Si cet
12. quipement est livr sans prise de cable veuillez connecter la prise de cable correcte selon le code suivant marron phase e bleu neutre e vert jaune terre 2 D brancher le courant avant de changer les lampes ou d effectuer des r parations 3 Cet quipement doit tre uniquement utilis dans des endroits secs Ne pas l exposer la pluie ou l humidit 4 l int rieur de l quipement il n y a pas de pi ces rempla ables par l utilisateur Confiez l entretien un personnel qualifi 5 Equipement de Classe I Cet quipement doit tre mis la terre Mise En Garde Pour Une Protection Permanente Contre Des Expositions Excessives an Rayons Ultra Violets UV Ne pas utiliser cet appareil si le bo tier de la lampe n est pas compl tement fix ou si les blindages lentilles ou crans ultraviolets sont endommag s 2 Changer les blindages ou les crans ultraviolets s ils sont visiblement endommag s au point que leur efficacit aient t alt r e par exemple par des fissures ou de profondes gratignures 3 Ne jamais regarder directement la lampe quand celle ci est allum e Mise En Garde Pour Une Protection Permanente Contre Les Blessures Corporelles 1 Lors de l assemblage utiliser un c ble de s curit secondaire 2 AVERTISSEMENT les lampes chaudes comportent un risque d explosion Apr s l avoir teinte attendre 5 minutes avant de la d gager Lors du remplacement de la lampe une protection des
13. to a control desk using DMX 512 5 Pin XLR RS 485 data cable only Fixtures must be linked to ColorPower using a 4 Pin XLR DATAPLEX Color Changer cable only For more information see Optional Accessories on page 1 6 Maximum total color changer cable length per ColorPower supply should not exceed 300 ft 91 m terminators to terminate both ends of ColorPower s fixture link Because you can connect two links with six fixtures per link on ColorPower this means that if you use only one link you must terminate the unused link on ColorPower as well as the last fixture in the used link If you use both fixture links you must terminate the last fixture on both links Warning ColorPower ships with two terminators You must use these 1 2 Features and Specifications ColorPower User Manual ColorCommand ColorCommand is a highly versatile color mixing PAR washlight that uses a simple compact incandescent lamp and an innovative patented dichroic color mixing system Because ColorCommand colors the whole beam simultaneously it ensures a smooth even field and allows you complete freedom when color mixing and adjusting beam size ColorCommand produces a huge range of colors from subtle pastels to deep saturates and everything in between ColorCommand can snap between one color and another in less than 1 3 second or make slow controlled fades ColorCommand uses dichroic borosilicate glass which will not fade or change color
14. yeux et des mains est requise 3 Les surfaces de l appareil peuvent atteindre des temp ratures de 100 C Laisser refroidir pendant 5 minutes avant la manipulation 4 Changer la lampe si elle est endommag e ou thermiquement d form e A 2 Important Safety Information ColorPower User Manual Anhang A Wichtige Hinweise F r Ihre Sicherheit Warnung Zum Schutz Vor Brandgefahr 1 PON Dieses Ger t ColorCommandTM ist nur f r den Gebrauch mit einer Philips 134205 750W 134213 800W Lampe Der Gebrauch irgend eines anderen Lampentyps k nnte Sie gef hrden und Ihre Garantie au er Kraft setzen Das Ger t nie auf einer feuergef hrlichen Fl che montieren Stets einen Mindestabstand von 0 3 Meter zu brennbaren Materialien einhalten Zum Ersatz nur Sicherungen verwenden die dem vorgeschriebenen Typ und Nennwert entsprechen Dieses Ger t darf nur an eine Zweigleitung mit einem berlastungsschutz von h chstens 20 A angeschlossen werden Warnung Zum Schutz Gegen Gef hrliche K rperstr me 1 3 4 5 Wenn dieses Ger t ohne einen Netzkabelstecker erhalten wurde ist der entsprechende Netzkabelstecker entsprechend dem folgenden Code anzubringen Braun Unter Spannung stehend e Blau Neutral e Grun Gelb Erde Vor dem Austauschen von Lampen oder vor Wartungsarbeiten stets den Netzstecker ziehen Diese Ger te sind nur zum Einbau in trockenen Lagen bestimmt und m ssen vor Regen A und Feuchtigkeit
15. Command must be operated with the High End Systems supply could damage the ColorCommand fixture Disconnect mains power from ColorPower before linking color changer cables to fixtures 2 4 Setup and Configuration ColorPower User Manual ColorPower has two output links that can supply 40VDC and data to the Dichroic Theatre Series fixtures The fixtures can be combined and linked in any configuration as long as there are no more than six 6 fixtures per output link Because ColorPower has two output links you can connect a maximum of twelve 12 fixtures for each ColorPower see Figure 2 5 Note Maximum total color changer cable length per ColorPower supply should not exceed 300 ft 91 m You can link one or more ColorPower units to a DMX Control desk using 5 pin DMX data cables Use Belden 9842 or equivalent meets specifications for EIA RS 485 applications data cables with the following characteristics e Two twisted pairs 4 conductors plus a shield Maximum capacitance between conductors lt 15 pF ft e Maximum capacitance between conductor and shield 55 pF ft Maximum resistance 20 Q 1000 ft Nominal impedance 120 Q DMX Control Desk ColorCommand a ColorPower 0400 6 maximum per link Figure 2 5 Dichroic Theatre Series linking diagram To connect ColorPower to ColorCommand fixtures you must use 4 pin XLR DATAPLEX Color Changer cabl
16. Cyan and Beam Angle Adjust ColorCommand Specifications Mechanical Height with yoke attached 445 mm 17 5 in Width with yoke attached 400 mm 15 8 in Depth with yoke attached 350 mm 13 8 in Weight 9 1 kg 20 Ib Figure 1 2 ColorCommand Physical Dimensions 1 4 Features and Specifications ColorPower User Manual Electrical Power Consumption 800 watts max Fuse 125V 2 5A Slow Blow SMF Power Input Ratings 115V 50 60Hz 7A 230V 50 60Hz 3 5A Environmental Specifications Max ambient temperature Ta 40 C 104 F Max exterior surface temperature T max 200 C 392 F Min distance to flammable objects 1 meter 3 28 ft Min distance to lighted object 1 meter 3 28 ft Lamp Specifications Lamp Philips Halogen Biplanar Lamp Type Lamp Life Color Temperature 750W G9 5 115V 300 hours 3200K 800W G9 5 230V 400 hours 3100K Typical Field Lumens 5000 Cabling and Terminator Specifications Fixtures must be linked using 4 Pin XLR DATAPLEX Color Changer Cable only For more information see Optional Accessories on page 1 6 A terminating plug provided with ColorPower must be installed in the last fixture in a fixture link ColorPower User Manual Features and Specifications 1 5 Optional Accessories The following accessories are available from High End Systems Part Description Part Number Ph
17. Systems Inc 2217 West Braker Lane Austin TX 78758 USA voice 512 836 2242 fax 512 837 5290 High End Systems Inc 2227 West Braker Lane Austin TX 78758 USA voice 800 890 8989 24 hour fax 512 834 9195 24 hour voice mail 512 837 3063 or 800 890 8989 High End Systems Inc New York 311 W 43rd Street Ste 400 New York NY 10036 voice 210 957 6840 fax 212 957 4466 High End Systems Inc 8200 Haskell Avenue Van Nuys CA 91406 US voice 818 947 0550 fax 818 908 8975 voice 352 241 8567 High End Systems Europe LTD 53 Northfield Road London W13 voice 44 20 8579 5665 fax 44 20 8579 8469 High End Systems Singapore Pte Ltd 1 Tannery Road 06 05 Cencon 1 Singapore 1334 voice 65 6742 8266 FAX 65 6743 9322 http www highend com ColorPower User Manual Declaration of Conformity according to ISO IEC Guide 22 and EN45104 Manufacturer s name High End Systems Inc Distributor s name High End Systems Inc Distributor s address 2217 West Braker Lane Austin Texas 78758 USA Declares that the product Product Name ColorPower Product Number All Product Options All conforms to the following EEC directives 73 23 EEC as amended by 93 68 EEC 89 336 EEC as amended by 92 31 EEC and 93 68 EEC Equipment referred to in this declaration of conformity was first manufactured in compliance with the following standards in 2003 Safety EN60950 2000 EMC EN55022 1998 Class A I
18. T PROFITS SUSTAINED OR INCURRED IN CONNECTION WITH ANY PRODUCT OR CAUSED BY PRODUCT DEFECTS OR THE PARTIAL OR TOTAL FAILURE OF ANY PRODUCT REGARDLESS OF THE FORM OF ACTION WHETHER IN CONTRACT TORT INCLUDING NEGLIGENCE STRICT LIABILITY OR OTHERWISE AND WHETHER OR NOT SUCH DAMAGE WAS FORESEEN OR UNFORESEEN Warranty is void if the Product is misused damaged modified in any way or for unauthorized repairs or parts This warranty gives you specific legal rights and you may also have other rights which vary from state to state ColorPower User Manual vii ColorPower User Manual Table of Contents Contacting High End Systems i ii Product Modification Warning nan na erne ener ennen nerne iv FCC Informations er M RS pe T A RS EE nt iv Important Safety Information e v SYMDOIS u sn nassen Rio vi Warranty Information sisi tte tentent nenn vii Chapter 1 Features and Specifications 0 1 1 COLOTPOWET NS 1 1 ColorPower Features 1 1 ColorPower Specifications ii 1 2 Mechanical sciita 1 2 IRA 1 2 Environmental Specifications i 1 2 Cabling and Terminator Specifications 1 2 1 3 ColorCommanrd Features nn Rasse 1 3 ColorCommand Specifications 1 4 Mechanical Electrical aree Loria lo RS Environmental Specifications
19. TE EN61000 3 2 EN61000 3 3 EN55024 1998 EN61000 4 2 Level 3 Class 2 EN61000 4 3 1995 Level 2 3V m EN61000 4 4 1995 Level 2 1 5kV EN61000 4 5 1995 Level 3 2 1kV EN61000 4 6 1965 Level 2 Vrms EN61000 4 11 1994 USA Monday August 04 2003 Kenneth Stuart Hansen Compliance Engineer ColorPower User Manual Product Modification Warning High End Systems products are designed and manufactured to meet the requirements of United States and International safety regulations Modifications to the product could affect safety and render the product non compliant to relevant safety standards Mise En Garde Contre La Modification Du Produit Les produits High End Systems sont con us et fabriqu s conform ment aux exigences des r glements internationaux de s curit Toute modification du produit peut entra ner sa non conformit aux normes de s curit en vigueur Produktmodifikationswarnung Design und Herstellung von High End Systems entsprechen den Anforderungen der U S Amerikanischen und internationalen Sicherheitsvorschriften Ab nderungen dieses Produktes k nnen dessen Sicherheit beeintr chtigen und unter Umst nden gegen die diesbez glichen Sicherheitsnormen versto en Avvertenza Sulla Modifica Del Prodotto I prodotti di High End Systems sono stati progettati e fabbricati per soddisfare i requisiti delle normative di sicurezza statunitensi ed internazionali Qualsiasi modifica al prodotto potrebbe pregiudic
20. and Configuration 2 9 Note For more information regarding the display and using the menu system see Chapter 3 Alphanumeric LED display 6 lt UP gt arrow button scrolls to the previous menu item or option Q lt DOWN gt arrow button scrolls to the next menu item or option O O MENU ENTER lt MENU gt button moves back to lt ENTER gt button selects a menu option the previous menu level Press and hold to enter the menu system Figure 2 6 ColorPower menu navigation buttons Press and hold lt Menu gt until d MX appears on the LED display Press lt Enter gt Use the arrow buttons to scroll to AddP Press and hold lt Enter gt until the display begins flashing Use the arrow buttons to scroll to the desired DMX start channel COO 7 C509 7 Press and hold lt Enter gt until the display stops flashing o mwN Manually Assigning a DMX Start Channel Manually assigning a DMX start channel to a fixture enables you to control which consecutive block of DMX channels are assigned to each fixture in a link For example you might choose to assign channels 150 153 to a ColorCommand that is identified as the first fixture in the link see Figure 2 7 Note A fixture is identified by its rotary switch setting which specifies its unit number To Address a fixture by manually assigning the start channel 1 Using ColorPower s menu system see Figure 2 6 on page 2 10 press and hold the l
21. arameter be assigned to a specific DMX channel in the fixture s channel range Channel assignments are based on the DMX protocol used ColorCommand uses a 4 channel protocol Parameters for each channel are described in the ColorPower Protocol Table on the following pages DMX values are given in decimal percentage and hexadecimal units Homing the Fixture Using a DMX Controller ColorPower and all connected units automatically home when power is initially applied You can rehome a fixture at anytime from the menu system see Reset and Home RST on page 3 3 You can also home the units using a DMX controller with the following procedure 1 Setthe ColorPower DMX channel to the appropriate value for the desired unit s see ColorPower DMX Protocol Table on page 3 5 and hold the value static for at least one second 2 Return the ColorPower DMX channel to 0 Safe The specified unit s will home 3 4 Fixture Operation ColorPower User Manual ColorPower DMX Protocol Table Chan Parameter Description ve 0 di Safe 0 15 0 6 00h OFh Display OFF 16 23 6 9 10h 17h Display DIM 24 31 9 12 18h 1Fh Display BRIGHT 32 39 13 15 20h 27h Reserved 40 47 16 18 28h 2Fh Reserved 48 63 19 25 30h 3Fh Home All 64 71 25 28 40h 47h Home Unit 0 72 79 28 31 48h 4Fh Home Unit 1 80 87 31 34 50h 57h Home Unit 2 88 95 35 37
22. are la sicurezza e rendere il prodotto non conforme agli standard di sicurezza pertinenti Advertencia De Modificaci n Del Producto Los productos de High End Systems est n dise ados y fabricados para cumplir los requisitos de las reglamentaciones de seguridad de los Estados Unidos e internacionales Las modificaciones al producto podrian afectar la seguridad y dejar al producto fuera de conformidad con las normas de seguridad relevantes FCC Information This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 ofthe FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense iv ColorPower User Manual Important Safety Information Instructions pertaining to continued protection against fire electric shock exposure to excessive ultraviolet UV radiation and injury to persons are found in Appendix A Please read all instructions prior to assembling mounting and operating this equipment Important In
23. before making any changes to fixture configuration on the fixture link ColorPower ships with two terminators You must use these terminators to terminate both ends of ColorPower s fixture link Because you can connect two links with six fixtures per link on ColorPower this means that if you use only one link you must terminate the unused link on ColorPower as well as the last fixture in the used link If you use both fixture links you must terminate the last fixture on both links Mounting the Fixtures You can mount ColorPower in any orientation suspended from a support system such as a truss Before mounting the fixture heed the warnings below to guard against personal injury and damage to the fixture 2 6 Setup and Configuration ColorPower User Manual Warning This equipment for connection to a branch circuit having a A maximum overload protection of 20 A Class I Equipment This fixture must be earthed Mount the fixtures and controllers in a location that is away from direct heat and protected from moisture Do not mount on a flammable surface For pluggable equipment the socket outlet shall be installed near the equipment and shall be easily accessible Use a secondary safety cable when mounting this fixture Caution Do not remove top cover of ColorPower or attempt to service while ColorPower is attached to rigging or truss When mounting ColorPower on a truss or another type of support do all of the fo
24. d Kingdom the colours of the cores in the mains lead of this equipment may not correspond with the colored markings identifying the terminals in the fixture s plug Therefore install a line cord cap according to the following code e The core which is coloured green and yellow must be connected to the plug terminal which is marked with the letter E or by the earth symbol or coloured green or green and yellow The core which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black The core which is coloured brown must be connected to the terminal which is marked with the letter E or coloured red A Warning Class 1 equipment This equipment must be earthed Vatic Fitter Heads Information Danmark Advarsel Beskyttelse mod elektrisk chock Vigtigt Lederne med gul groen isolation maa kun tilsluttes en klemme maerket D eller Installing the Lamp in ColorCommand The ColorCommand fixture ships without a lamp Use the following procedure to install a lamp in a new fixture or to replace a lamp Warnings Disconnect power before lamping relamping or servicing Replace the lamp if it becomes damaged or thermally deformed An operating unshielded lamp emits ultraviolet and visible UV vis radiation which could damage eyes and skin Whenever you J are working on or near an exposed lamp wear protective eye gear Never look directly at the lamp while the la
25. dure do not automatically change if a unit fails or is disconnected Verifying and Uploading ColorPower Software 1 Use the menu system to identify the current version of software running on ColorPower See Chapter 3 2 Verify that the version displayed by ColorPower is the latest available The latest software is available in the support section of the High End Systems website www highend com 3 If a software upgrade is required attach a High End Systems Upload Dongle to the computer and upload the software to ColorPower A High End Systems Upload Dongle requires a 386 based or faster computer MS DOS version 3 3 or later or Windows 95 98 ME and one MB of free disk space To obtain an Upload Dongle with installation and operation instructions contact your High End Systems dealer distributor see Contacting High End Systems on page ii Note ColorCommand is controlled using the software stored in ColorPower Therefore you only need to upload ColorPower software when applicable 2 12 Setup and Configuration ColorPower User Manual Fixture Maintenance ColorPower and ColorCommand have no user serviceable parts inside If your fixture requires maintenance contact customer support see Contacting High End Systems on page ii Cleaning the ColorCommand Lens Den Disconnect power and turn power switch off before servicing Equipment surfaces may reach temperatures up to 67 C 153 F A
26. ent for connection to branch circuit having a maximum overload protection of 20 A Warning For Continued Protection Against Electric Shock 1 If this equipment was received without a line cord plug attach the appropriate line cord plug according to the following code e brown live e blue neutral green yellow earth 2 Asthe colours of the cores in the mains lead of this equipment may not correspond with the coloured markings identifying the terminals in your plug proceed as follows e the core which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol O or coloured green or green and yellow e the core which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black e The core which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red 3 Class I equipment This equipment must be earthed 4 Equipment suitable for dry locations only Do not expose this equipment to rain or moisture 5 Disconnect power before re lamping or servicing 6 Refer servicing to qualified personnel no user serviceable parts inside Warning For Continued Protection Against Exposure To Excessive Ultraviolet UV Radiation 1 Do not operate this equipment without complete lamp enclosure in place or if shields lenses or ultraviolet screens are damaged 2 Change shields lenses
27. es Although these cables do not ship with ColorPower High End Systems offers them as optional accessories see Optional Accessories on page 1 6 ColorPower User Manual Setup and Configuration 2 5 The 4 pin XLR DATAPLEX Color Changer pin designation is as follows e Pin 1 Black 14 40VDC e Pin 2 Red 22 Data e Pin 3 Green 22 Data e Pin 4 White 14 40 VDC DMX protocol varies according to the number of fixtures in the link ColorPower requires one DMX channel ColorCommand fixtures require 4 DMX channels For more information see Chapter 3 Setting up the Link Complete the following to link one or more fixtures as shown in Figure 2 5 1 Connect the male XLR connector of a 5 pin DMX data cable to your DMX controller s DMX Data Out connector 2 Connect the female XLR connector of the 5 pin DMX data cable to a ColorPower Connect the male XLR connector of a 4 pin XLR DATAPLEX Color Changer cable to ColorPower s Data Out connector 4 Connect the female XLR connector of the 4 pin XLR DATAPLEX Color Changer cable to the first fixture on the fixture link 5 Continue linking the remaining ColorCommand fixtures together by connecting a 4 pin XLR DATAPLEX Color Changer cable from the Data Out connector of each fixture to the Data In connector of the next fixture on the link 6 Connect a male terminator to the Data Out connector of the last fixture in the link Warning Unplug power from ColorPower
28. f the new Dichroic Theatre series product family from High End Systems Features and specifications for each product in the series are listed below ColorPower ColorPower is a power supply unit designed for the ColorCommand fixtures that can provide DMX data to 12 color mixing units You can either manually assign a DMX start address for each unit linked to ColorPower or allow ColorPower to assign the DMX start addresses automatically The front panel on ColorPower has a LED Light Emitting Diode display that enables you to access the menu system to configure linked Dichroic Theatre Series fixtures and assign DMX start channels ColorPower Features e Provides DMX data for 1 12 Color mixing fixtures Menu system for easy DMX addressing of ColorCommand fixtures e Lightweight and easy to mount ColorPower User Manual Features and Specifications 1 1 ColorPower Specifications Mechanical Height 137 mm 5 4 in Width 311 mm 12 3 in Depth 309 mm 12 2 in Weight 5 9 kg 13 Ib Electrical Power Output Ratings 40VDC 750mA Power Input Ratings 120V 230V 50 60Hz 3A 1 5A Environmental Specifications Max ambient temperature Ta 40 C 104 F Max exterior surface temperature T max 100 C 212 F z Figure 1 1 ColorPower Physical Dimensions Min distance to flammable objects 3 meter 12 in Cabling and Terminator Specifications ColorPower must be connected
29. formations De S curit Les instructions se rapportant la protection permanente contre les incendies P lectrocution l exposition un rayonnement ultraviolet UV excessif et aux blessures corporelles se trouvent dans l Annexe A Veuillez lire toutes les instructions avant d assembler de monter ou d utiliser cet quipement Wichtige Sicherheitshinweise Sicherheitsanleitungen zum Schutz gegen Feuer elektrischen Schlag berm ige UV Strahlung und Verletzung von Personen finden Sie in Anhang A Vor der Montage dem Zusammenbau und der Intbetriebnahme dieses Ger ts alle Anleitungen sorgf ltig durchlesen Informazioni Importanti Di Sicurezza Le istruzioni sulla protezione da incendi folgorazione esposizione eccessiva a raggi ultravioletti UV e infortuni sono contenute nell appendice A Si prega di leggere tutte le istruzioni prima di assemblare montare e azionare l apparecchiatura Informacion Importante De Seguridad En el Ap ndice A se encuentran instrucciones sobre protecci n continua contra incendios descarga el ctrica exposici n excesiva a radiaci n ultravioleta UV y lesiones personales Lea por favor todas las instrucciones antes del ensamblaje montaje y operaci n de este equipo ColorPower User Manual v Symbols The following international caution and warning symbols appear in margins throughout this manual to highlight messages A PN di 4 af N gt Caut
30. g the lt Up gt and lt Down gt arrow buttons scroll to the VERS option and press the lt Enter gt button to select The current ColorPower software version number will be displayed Check with the High End Systems website www highend com to verify that this is the latest version If you need to install new software see Verifying and Uploading ColorPower Software on page 2 12 Display the Unit Information UNIT To view unit information for each fixture on the link 1 If you are not already in the Menu system press and hold the lt Menu gt button until DMX appears on the LED display 2 Usingthe lt Up gt and lt Down gt arrow buttons scroll to the NFO menu and press the lt Enter gt button to select 3 Usingthe lt Up gt and lt Down gt arrow buttons scroll to the U V 7 option and press the lt Enter gt button to select The available data for the fixtures connected to the fixture link displays For example 1 CC means that a ColorCommand fixture is connected to the link and its rotary switch is set to 1 3 2 Fixture Operation ColorPower User Manual Control CTRL Menu Use this Menu option to reset ColorPower and home all ColorCommand fixtures connected to the fixture link Reset and Home RST To view the Software version currently running on the fixture 1 If you are not already in the Menu system press and hold the lt Menu gt button until DMX appears on the LED display 2 Using the lt
31. i 0 3 metri 0 98 piedi di distanza dai materiali combustibili Sostituire i fusibili usando soltanto quelli del tipo e della taratura adatta Questa apparecchiatura e da collegarsi ad un circuito con una protezione da sovraccarico massima di 20 ampere Avvertenza Per Prevenire Le Scosse Elettriche 1 Se questa apparecchiatura stata consegnata senza una spina del cavo di alimentazione collegare la spina appropriata del cavo di alimentazione in base ai seguenti codici e marrone fase e blu neutro verde giallo terra 2 Disconnettere la corrente prima di cambiare la lampada o prima di eseguire qualsiasi riparazione 3 Questo apparecchio deve essere utilizzato in ambienti secchi Non deve essere esposto a pioggia o montato in luoghi umidi 4 Per qualsiasi riparazione rivolgersi al personale specializzato L utente non deve riparare nessuna parte dentro l unita 5 Aparecchio di Classe I Questa apparecchiatura deve essere messa a terra Avvertenza Protezione Contro Le Radiazioni Dei Raggi Ultravioletti Non usare questa apparecchiatura se il sistema di chiusura della lampada non e completo o se gli schermi le lenti o gli schermi ultravioletti si sono visibilmente danneggiati di maniera tale che la loro efficacia sia stata ridotta ad esempio se vi sono visibili spaccature o graffi profondi Mai guardare direttamente verso la lampada quando sia accesa Avvertenza Per Non Ferire Ad Altre Persone 1 Montare quest
32. ilips Halogen Biplanar lamp 750W G9 5 115V 55030064 Philips Halogen Biplanar lamp 800W G9 5 230V 55030065 Additional Terminator plug 80470215 4 pin XLR DATAPLEX Color Changer cable 6 65040001 4 pin XLR DATAPLEX Color Changer cable 10 65040002 4 pin XLR DATAPLEX Color Changer cable 25 65040003 4 pin XLR DATAPLEX Color Changer cable 50 65040004 5 pin XLR DMX Data Cable Heavy Duty 10 55050017 5 pin XLR DMX Data Cable Heavy Duty 25 55050018 5 pin XLR DMX Data Cable Heavy Duty 50 55050019 5 pin XLR DMX Data Cable Heavy Duty 100 55050020 Whole Hog Ill Lighting Console 61020001 DMX Upload dongle 26040002 Safety cable 90701349 Cheeseborough truss clamp 55040014 Note Call High End Systems for information on optical module replacement see Contacting High End Systems on page ii 1 6 Features and Specifications ColorPower User Manual Chapter 2 Setup and Configuration ColorPower ships with the following items e ColorPower supply e User manual e Two 2 terminator plugs One power cord plug molded for US e Safety cable ColorCommand ships with the following items e ColorCommand fixture with attached yoke One power cord without a cord cap e Declaration of Conformity e Safety cable Unpacking the Products Unpack your products and verify that they are undamaged If there is no damage continue with the rest of the setup procedure described in this chapter If there
33. ing a DMX Start Channel When automatically assigning DMX start channels to fixtures on a link ColorPower allocates the DMX addresses in the order of each fixture s unit number specified by the rotary switch setting on each fixture see Figure 2 8 To Address a fixture by automatically assigning the start channel 1 Using ColorPower s menu system see Figure 2 6 on page 2 10 press and hold the lt Menu gt button until dMX appears on the LED display 2 Press lt Enter gt 3 Using the lt Up gt and lt Down gt arrow buttons scroll to the MOdE menu and press the lt Enter gt button to select 4 Using the lt Up gt and lt Down gt arrow buttons scroll to the AUtO menu and press the lt Enter gt button to select 5 Press the lt Enter gt button until DONE displays ColorPower User Manual Setup and Configuration 2 11 Unit 3 DMX Start channel 10 Unit 2 Channel range 10 11 12 13 DMX Start channel 6 Channel range 9 ColorPower DMX channel 1 Unit 1 DMX Start channel 2 Channel range 2 3 4 5 Unit 4 DMX Start channel 14 Channel range 15 16 17 Figure 2 8 Sample automatic assignment of DMX start channels IMPORTANT You must complete this procedure after all fixtures have been added to the fixture link ColorPower only assigns start channels automatically after all steps in this procedure are completed In other words the start channels assigned using this proce
34. ion This symbol appears adjacent to Caution messages Not heeding these messages could result in personal injury and or damage to equipment Warning This symbol appears adjacent to high voltage warning messages Not heeding these messages could result in serious personal injury This symbol indicates that a fire hazard is present Not heeding these messages could result in serious personal injury This symbol indicates that eye protection is required This symbol indicates an explosion hazard This symbol indicates the minimum distance to a lighted object which in this case is 1 meter This symbol indicates a hot surface This symbol indicates that an object not be mounted on a flammable surface ColorPower User Manual Warranty Information Limited Warranty Unless otherwise stated your Product unit is covered by a one year parts and labor limited warranty Dichroic filters are not guaranteed against breakage or scratches to coating It is the owner s responsibility to furnish receipts or invoices for verification of purchase date and dealer or distributor If purchase date cannot be provided date of manufacture will be used to determine warranty period Returning an Item Under Warranty for Repair It is necessary to obtain a Return Material Authorization RMA number from your dealer or point of purchase BEFORE any units are returned for repair The manufacturer will make the final determination as to whether or n
35. llow the fixture to cool before handling Clean the front ColorCommand lens using a mild glass cleaner containing no ammonia and a soft lint free cotton cloth Replacing the ColorCommand Lamp For information on replacing the lamp in a ColorCommand fixture see Installing the Lamp in ColorCommand on page 2 2 Maintenance Mode When performing maintenance you can set all fixtures in a link to maintenance mode This enables ColorPower to automatically locate or discover each fixture on the link and assign it a DMX start channel To place all fixtures in a link in maintenance mode 1 Using ColorPower s menu system see Figure 2 6 on page 2 10 press and hold the lt Menu gt button until dMX appears on the LED display 2 Press lt Enter gt 3 Using the lt Up gt and lt Down gt arrow buttons scroll to the MOdE menu and press the lt Enter gt button to select 4 Using the lt Up gt and lt Down gt arrow buttons scroll to the D SC menu and press the lt Enter gt button to select 5 Press the lt Enter gt button until DONE displays IMPORTANT After performing any maintenance you must return all fixtures to either Manual MANU mode or Automatic AUTO mode for operation For more information see Manually Assigning a DMX Start Channel on page 1 10 or Automatically Assigning a DMX Start Channel on page 1 11 ColorPower User Manual Setup and Configuration 2 13 2 14 Setup and Configura
36. llowing e Verify the truss or support will handle the combined weight of all the devices on the truss Each ColorPower fixture weighs 5 9 kg 13 lb Each ColorCommand fixture weighs 9 1 kg 20 Ib High End Systems strongly recommends using safety cables to attach any of its fixtures to a truss Safety cables are provided with ColorPower and ColorCommand fixtures If necessary you can order additional safety cables from your High End Systems dealer distributor see Optional Accessories on page 1 6 e You must supply your own clamps to attach the fixture to the support Verify that the clamp s you use are capable of supporting the weight of the fixture You can order cheeseboroughs for a two inch truss from your High End Systems dealer distributor see Optional Accessories on page 1 6 Make sure the fixture cannot be rotated all the way around 360 Allowing the fixture to rotate 360 could loosen the clamp mounting bolts Note Because of the variety of conceivable lighting designs you should consider the procedure below as a suggested guideline only High End Systems Inc cannot make specific recommendations for your particular lighting design or venue To mount the fixture to a truss or another type of support Attach a suitable clamp through one of the holes on top of the yoke If you are attaching one clamp use the middle hole on the yoke If you are attaching 2 clamps per fixture attach one clamp to each
37. mp is on al Hot lamp Let the lamp cool before replacing 2 2 Setup and Configuration ColorPower User Manual Biplanar lamp only Using any other type lamp may be hazardous f Caution This equipment is designed for use with a Philips Halogen and will void the warranty To install a lamp in a new fixture or replace a lamp in an existing fixture 1 Perform this procedure before you connect the fixture to power 2 Put on protective eye wear and gloves 3 Access the lamp cap on the rear lamp socket housing and loosen the two thumbscrews 4 Gently remove the socket housing from the reflector mount exposing the lamp as shown in Figure 2 1 5 Remove the lamp from the socket housing 6 The lamp assembly is Figure 2 1 Removing the lamp connected to the fixture by lamp socket wires Support the lamp assembly while inserting the lamp Do not allow the lamp socket wires to support the weight of the lamp assembly 7 Remove all packaging materials from the new Philips 800W max lamp 8 Holding the new lamp by its base gently press the two base pins straight into the lamp socket until the lamp is firmly seated as shown in Figure 2 2 Note To avoid premature lamp failure do not touch the lamp glass If you touch the glass clean the lamp glass carefully with rubbing alcohol and a clean lint free cloth Figure 2 2 Installing the lamp 9 Gently replace the lamp socket housing on the reflector mount
38. nnel range ColorPower requires one channel ColorCommand fixtures require 4 consecutive channels on the link The DMX start channel assigned to a particular fixture is the first channel available to a fixture in its channel range The fixture s channel range must not overlap any other device s channel range on the link When two devices on the same DMX link have overlapping channel ranges one or both devices will be disabled or behave erratically Remember the following criteria when determining a valid start channel e The Start channel is the number of the first channel in a consecutive block of channels assigned to an individual fixture e A fixture can be assigned the second block of DMX channels on a link without physically being the second fixture on the link e To avoid overlapping channels place the start channel at the beginning of a range of available channels large enough to accommodate that fixture type e Every channel in the link does not need to be assigned e The channel range required for a fixture differs depending on the fixture type You can assign a DMX start channel to a fixture either manually or automatically using ColorPower Assigning a DMX Start Channel to ColorPower To set the ColorPower Address for the single DMX channel it uses 1 Access ColorPower s menu system via the LED display and four menu navigation buttons to assign a Start channel to ColorPower ColorPower User Manual Setup
39. o apparecchio utilizzando il cavo secondario di sicurezza 2 Avvertenza la lampada calda potrebbe esplodere Spegnerla per 5 minuti prima di aprirla Usare protezioni per le mani e per gli occhi prima di cambiare la lampada 3 Le superfici della apparecchiatura possono arrivare a temperature di 100 gradi centrigradi 212 gradi f Aspettare 5 minuti prima di maneggiare 4 Cambiare la lampada se si e danneggia o se si e deformata dal calore ar ColorPower User Manual Important Safety Information A 5 Vigtig Sikkerhedsinformation Advarsel Beskyttelse mod elektrisk chock VIGTIGT LEDEREN MED GUL GROEN ISOLATION MAA KUN TILSLUTTES KLEMME MAERKET amp ELLER A 6 Important Safety Information ColorPower User Manual
40. olorPower User Manual High End Systems Inc 2003 All Rights Reserved Information and specifications in this document are subject to change without notice High End Systems Inc assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual Trademarks used in this text High End Systems WholeHog III H and LithoPatterns are registered trademarks and ColorCommand and ColorPower the High End Systems globe logo Hog and the Hog logo are trademarks of High End Systems Inc or High End Systems Europe Ltd High End Systems is fully responsible for the ColorPower and ColorCommand products ColorCommand covered by patents 6 502 961 6 142 652 and 6 048 081 Belden is a registered trademark of Belden Inc Philips is a registered trademark of Philips Lighting Company ETL and C ETL are registered trademarks of Intertek Testing Services Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products High End Systems disclaims any proprietary interest in trademarks and trade names owned by others ColorPower User Manual P N 60600229 Version 1 1 August 2003 olorCommand ColorPower User Manual i Contacting US and the Americas Sales Department Customer Service U S New York U S Los Angeles Orlando Europe Headquarters Singapore World Wide Web High End Systems High End
41. ord cap is installed as described in Installing a Power Cord Cap on page 2 1 Make sure the rotary switch on all fixtures has been set as described in Unit Addressing on page 2 4 Make sure ColorPower is linked appropriately to all fixtures in the fixture link as described in Installing the Lamp in ColorCommand on page 2 2 At this point it is safe to connect ColorPower to an appropriately rated power source which turns ColorPower on Note ColorCommand fixtures use a thermal protection relay A ColorCommand fixture must have a 4 pin XLR Color Changer cable connected or the lamp will not turn on Connecting ColorCommand to Power Connect the ColorCommand lamp cable to mains power or a suitable dimmer 2 8 Setup and Configuration ColorPower User Manual Homing ColorCommand When ColorCommand fixtures are connected to ColorPower they automatically begin a homing procedure to verify that the major functions of the fixture are oriented properly ColorPower s menu system provides an option for re homing the fixtures See Chapter 3 for instructions on using the Menu system and locating the Home function Assigning a DMX Start Channel The DMX start channel identifies each fixture on a link for the DMX controller There are 512 available channels on each DMX link These 512 channels are divided among allthe devices on a particular link The number of channels a fixture requires is called the fixture s cha
42. ot the unit is covered by warranty Lamps are covered by the lamp manufacturer s warranty Any Product unit or parts returned to High End Systems must be packaged in a suitable manner to ensure the protection of such Product unit or parts and such package shall be clearly and prominently marked to indicate that the package contains returned Product units or parts and with an RMA number Accompany all returned Product units or parts with a written explanation of the alleged problem or malfunction Ship returned Product units or parts to 2209B Rutland Suite 110 Austin TX 78758 USA Note Freight Damage Claims are invalid for fixtures shipped in non factory boxes and packing materials Freight All shipping will be paid by the purchaser Items under warranty shall have return shipping paid by the manufacturer only in the Continental United States Under no circumstances will freight collect shipments be accepted Prepaid shipping does not include rush expediting such as air freight Air freight can be sent customer collect in the Continental United States REPAIR OR REPLACEMENT AS PROVIDED FOR UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER HIGH END SYSTEMS INC MAKES NO WARRANTIES EXPRESS OR IMPLIED WITH RESPECT TO ANY PRODUCT AND HIGH END SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE HIGH END SHALL NOT BE LIABLE FOR ANY INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGE INCLUDING LOS
43. t Menu gt button until dMX appears on the LED display Press lt Enter gt Using the lt Up gt and lt Down gt arrow buttons scroll to the MOdE menu and press the lt Enter gt button to select 4 Using the lt Up gt and lt Down gt arrow buttons scroll to the MAnU menu and press the lt Enter gt button to select 2 10 Setup and Configuration ColorPower User Manual Unit 3 DMX Start channel 101 Channel range 101 102 103 104 Unit 1 DMX Start channel 300 Channel range 300 301 302 303 ColorPower DMX channel 100 00040 Unit 2 DMX Start channel 150 Channel range 150 151 152 153 Unit 4 DMX Start channel 200 Channel range 200 201 202 203 Figure 2 7 Sample manual assignment of DMX start channels 5 Using the lt Up gt and lt Down gt arrow buttons scroll to the UN t menu and press the lt Enter gt button to select 6 Using the lt Up gt and lt Down gt arrow buttons scroll to the desired fixture unit number and press the lt Enter gt button to select the desired unit For example 1 CC means a ColorCommand unit with a rotary switch setting of 1 7 Using the lt Up gt and lt Down gt arrow buttons scroll to the desired DMX start channel C001 C570 and press the lt Enter gt button to select Note The last valid Start channel for a ColorCommand 4 channel protocol fixture on a 512 channel DMX link is Channel 509 Automatically Assign
44. tion ColorPower User Manual Chapter 3 Fixture Operation This chapter contains information on using the ColorPower menu system and DMX programming to operate and control the fixture Use the Menu Map on page 3 3 for a quick reference on menu options Accessing the Menu System To access the menu system press and hold the lt Menu gt key until DMX appears on the LED display The menu system is protected against inadvertent menu changes by requiring the lt Menu gt button to be held for a few seconds before allowing entry to the menus To exit the menu system you must keep pressing the lt Menu gt button to back out of each menu level until you reach the top menu level After approximately 2 minutes the display will revert to the fixture s currently assigned DMX start channel Basic Navigation The navigation buttons on the fixture s display panel allow you to navigate through the onboard menu system As you navigate the menu system the alphanumeric display will show the menu items you select from the menu map e Press the lt Up gt and lt Down gt arrow buttons to move to the Menus and options The alphanumeric display will flash when a new option is selected and will stop flashing when a new option is stored by pressing the lt Enter gt button Note If you do not press the lt Enter gt button the new option you selected will not be stored Alphanumeric LED display j gt lt UP gt arrow button scrolls
45. to the previous menu item or option Q lt DOWN gt arrow button scrolls to the next menu item or option SES MENU ENTER lt MENU gt button moves back to lt ENTER gt button selects a menu option the previous menu level Press and hold to enter the menu system Figure 3 1 ColorPower Menu display panel ColorPower User Manual Fixture Operation 3 1 e Ifyou have not pressed lt Enter gt pressing the lt Menu gt button returns you to the previous menu without changing the value of an option Menu Options The following sections describe the information and operations available under each of the Level 1 Menus and include option selection examples DMX Menu Use this Menu option to set the Start channel for ColorPower supply and ColorCommand fixtures For more information on setting a DMX start channel see Assigning a DMX Start Channel to ColorPower on page 2 9 For information on the maintenance mode see Maintenance Mode on page 2 13 Information INFO Menu Use this Menu option to display information on software versions and connected units Display the Software Version VERS To view the Software version currently running on the fixture 1 If you are not already in the Menu system press and hold the lt Menu gt button until DMX appears on the LED display 2 Using the lt Up gt and lt Down gt arrow buttons scroll to the NFO menu and press the lt Enter gt button to select 3 Usin
46. uipo sin tener colocada en su lugar la caja protectora completa de la l mpara o bien si el blindaje los lentes o las pantallas ultravioletas est n da adas Cambie el blindaje los lentes o las pantallas ultravioleta si nota una aver a visible a tal grado que su eficacia se vea comprometida Por ejemplo en el caso de grietas o rayaduras profundas Jam s mire directamente a la l mpara mientras sta est encendida Advertencia Para Protecci n Continua Contra Lesiones Corporales 1 Almontareste sparato ulilize un cable de seguridad secundario 2 Precauci n una l mpara caliente puede constituir un peligro de explosi n No la habra por 5 minutos luego de haberla apagado Lleve puestos un protector ocular y guantes al cambiar l l mparas 3 Las superficies del equipo pueden alcanzar temperaturas m ximas de 100 grados cent grados Deje que se enfr en por 5 minutos antes de tocarlas 4 Cambie la l mpara si sta se aver a o deformada por acci n t rmica A 4 Important Safety Information ColorPower User Manual Appendice A Importanti Informazioni Di Sicurezza Avvertenza Per Prevenire Incendi 1 Questa apparecchiatura ColorCommandTM stata progettata per l uso esclusivo con lampada Philips 134205 750W 134213 800W L uso di qualsiasi altro tipo di lampada pu essere pericoloso e pu annullare la garanzia 2 Da non montare sopra una superficie infiammabile 3 Mantenere l apparecchio a un minimo d
Download Pdf Manuals
Related Search
Related Contents
SUJET N° 1 - CRDP de Montpellier EVGA 02G-P4-2661-KR NVIDIA GeForce GTX 660 2GB graphics card Focoltone ICCS Installation & User Manual Copyright © All rights reserved.
Failed to retrieve file