Home

User manual

image

Contents

1. only on F models only on DMX models only on F and DMX models FL 75 XT 2 B FandC Halogen light generator gt Colour or twinkle wheel on off o gt Code wheel FL Lamp Colour wheel Dimmer wheel for Roblon Fiber Optics exterior lighting systems FL 75 XT 2 B F and C User Manual Introduction Your Roblon Fiber Optics halogen light generator type FL 75 XT 2 is intended for outdoor use in fiber optic lighting systems using either glass or PMMA fibers The halogen light generator has been developed to meet the requirements of a Roblon fiber optic lighting system where the light output intensity and efficiency is optimized in order to ensure the best performance and safety This manual should serve as a guideline how the system is operated in the safest way Following the recommendations in this guideline all contributes to o Enhanced functionality o Extended lifetime of components o Uninterrupted system illumination Contents Product overview and packing list Technical information Installation instructions Control feature for FL 75 XT 2 F Mount the light generator Mount the light generator on a wall Mount the light generator on a mounting bracket Remember Air flow in tube Change the lamp
2. The light generator has to get the heat away from the lamp Do not place two light generators on top of each other Make sure that the hot air from one light generator does not blow directly into the air intake of the light generator next to it FL 75 XT 2 B F and C User Manual Airflowintube Light generators needs to get fresh air to keep cool In small rooms it will be necessary to separate air intake and air exhaust It can be done with a tube The following shows how tube is mounted on the exhaust pipe Use a flex tube with a 70 75 mm internal opening Max tube length 4 m Required air flow is 30 m h per light generator N Air intake _ Air Exhaust Remove the 3 screws from the box Remove the box and replace the screws Place the tube and tighten screw clamp FL 75 XT 2 B F and C User Manual Change the lamp Turn off the light generator Open the door Release the lamp plug Remove the lamp The new lamp is installed in reverse order Turn off the light generator Open the door and take out the fuse holder Change the fuse _ Mount the fuse holder SEE ILLUSTRATION ON PAGE 2 FL 75 XT 2 B F and C User Manual Change the fan 10 Turn off the light generator Release the fan plug oa Jre Loosen screw Tip the bracket plate in the bottom and remove the fan from the light generator Remov
3. 016 2 Set the DMX control feature When the DMX channel is set on the code wheel it is possible to set the three channels on a DMX control feature like the Linebacker or Alcorn McBride Control 1 channel 5 sec delay on all functions 13 FL 75 XT 2 B F and C User Manual Control feature for DMX models 201 205 Frames 1 000 200 100 133 through 6 at Dimming wheel 3 channel Frames 1 000 200 033 067 100 133 167 through 6 at 14 FL 75 XT 2 B F and C User Manual Control features for synchronized models Controlling can be done by a master or a control unit Key features e Selection of full colour e Selection of colour wheel rotation speed and direction Connect the synchron light generators into the line of light generators via a shielded twisted pair type DMX cable Slave Slave Slave Slave Master Slave Slave Slave Control uni t iT ai i a TT m mi Set the light generator as Master by setting the code wheel 3 to 9 Set all the connected Slave light generators to channel 800 and they will be synchronized with your choise of program on the Master light generator or control unit that should be set according to next page Master Slave Wneel 2 a O Q So ollo C TOCIL Site ES A SA a A 99081038 8 built in standard programs for colour changing are available 15 FL 75 XT 2 B C a
4. 99082045 rev 2 0 FL 75 XT 2 B F and C Halogen light generator for Roblon Fiber Optics exterior lighting systems EU 01510350 01510351 01510356 01510353 01510355 01510352 01510354 US 01510250 01510251 01510256 01510253 01510255 01510252 01510254 This user manual describes the installation and service of the following products Product FL 75 XT 2 B FL 75 XT 2 F Colour Wheel FL 75 XT 2 F Twinkle Wheel FL 75 XT 2 C Synchron FL 75 XT 2 C DMX Dual Wheel FL 75 XT 2 C DMX Colour Wheel FL 75 XT 2 C DMX Dimmer Wheel Roblon Fuse 230 V in g E age lo EU model 120 V in US model DMXin DMX out Connection board Hole for locking light generator on bracket or wall Fan 4b Pg
5. Change the fuse Change the fan O O ON NO ODO oO BR BA ek eek Stand alone mode for DMX models NO Connecting for DMX models oO Control features for DMX models Ol Control features for synchronized models N Trouble shooting 00 Spare parts FL 75 XT 2 B F and C User Manual Product overview and packing list Contents of this box 1 light generator FL 75 XT 2 series 1 key 1 Allen key 4 mounting fittings 1 user manual Screws for wall mounting Technical information Light port size O9 O28 mm Fiber type PMMA Glass Supply voltage EU 230 V nominal 50 60 Hz US 120 V 60 Hz Fan noise level 28 5 db A Ambient temperature Lamp colour temperature Material Steel electro galvanised and powder coated Dimensions L x W x H 250 x 355 x 165 mm rs Safety approvals CE EMC comply FCC comply CB CSA Degree of protection IP 45 FL 75 XT 2 B F and C User Manual Installation instructions Unpack the unit and make sure that the grounded power supply cord is suitable for your country Use the key to open the door Insert the fiber harness commond end fully into the output port of the light generator Tighten the grille screw with the supllied Allen key and mount the plug in the hole Control feature for FL 75 XT 2 F Not for US Colour or Twinkle wheel ON OFF SEE ILLUSTRATION ON PAGE 2 Extern ON OFF wiring Blue N Brown L1
6. a DMX controller to the IN connection on the light generators DMX connection board SEE ILLUSTRATION Mount the DMX cable in the first light generators OUT connection to the light next generators IN connection See Fig 1 In the last light generator there has to be a line termination in the OUT connection factory mounted See Fia 2 Pin2 Pin3 Pin2 Pin3 Pin2 Pin3 data data data data data data In Shield Out In Shield Line Termination FL 75 XT 2 B F and C User Manual Control features for DMX models 1 Setting the DMX channel on the light generator The light generator is normally using 3 DMX channels The first is set with the code wheels 1 2 3 between 001 and 512 The next two will automatic be the two following DMX channels Example If the code wheels are set to 016 then the two next will be 017 and 018 Example The DMX channel is set to
7. e the screws Install a new fan in reverse order Note the arrow showing the air flow through the fan The arrow must point out of the light generator After installing the fan check the air flow The air has to blow out at the side where the fan is placed FL 75 XT 2 B F and C User Manual Stand alone mode for DMX models Six built in programs for colour changing and choosing are available Code Wheel 1 9 The light generator is in stand alone mode Code Wheel 2 Varies the pauses between the changes 0 is the shortest and 9 is the longest Code Wheel 3 Smooth colour change between green and orange Colours change at 50 dimming on models with dimming wheel Colours change at 50 dimming on models with dimming wheel 5 Smooth colour change between green orange blue red yellow and backwards Colours change at 50 dimming on models with dimming wheel Smooth colour change between blue and red Full colour Use code wheel 2 to change colour 1 White 2 Green 3 Orange 4 Blue 5 Red and 6 Yellow 11 FL 75 XT 2 B F and C User Manual Connecting for DMX models Connections with screw terminals Max signal cable length of the whole installation is 120 meters and max 30 DMX units Control unit eT TT ou TOD mi If there is more than one light generator they must be connected in a daisy chain connection Mount DMX the cable from
8. en DMX and Synchron light generators 9903 0055 DMX and Synchron Please state required length Cable Cable between DMX Synchron control unit and light generators 9903 0060 Please state required length 18 Roblon accepts no responsibility for possible errors in printed and electronic material Roblon reserves the right to alter or discontinue products without notice 2012 Roblon A S Roblon Roblon Lighting Nordhavnsvej 1 9900 Frederikshavn Denmark Tel 45 9620 3300 Fax 45 9620 3399 info roblon com www roblon com
9. lamp fan Black L2 motor Yellow green FL 75 XT 2 B F and C User Manual Mount the light generator Important Mount the light generator on a wall place it on a mounting bracket or lie it on the back side of the light generator Not IP 45 when pla ced on the back side Mount the light generator on a wall Mark two holes with 130 mm in between Drill O8 mm holes ARRNK OAKEN KA Use rawplugs to mount the pins on the wall To lock the light generator to the wall mark through the hole in the bottom Remove the light generator and drill 6 mm hole Mount rawplugs in the hole SEE ILLUSTRATION ON PAGE 2 Place the light generator on the pins and mount the screw H Mount the plug FL 75 XT 2 B F and C User Manual Mount the light generator on a mounting bracket Place the mounting bracket Mount the light generator on the two pins Mount the screw M4 x 20 to secure the light generator The space between the light generator and larger items must be more than 150 mm
10. nd F User Manual Control feature for synchronized models Programs are set with the code wheel 1 Program 0 and 7 Not used white light Program 1 and 2 1 Fast 0 2 sec colour change between all the colours of the wheel 2 Smooth 5 sec colour change between all the colours of the wheel Pauses in program 1 and 2 Program 3 4 and 5 3 Slow colour change between green and orange 4 Slow colour change between blue and red 5 Slow colour change between green orange blue red yellow and backwards Pauses in program 3 4 and 5 Godewheet2nen o 1 2 3 4 s o 7 elo 15 Pause in sec Lo en ON es I Tears 20 225i 7228 2S 30 Program 6 Colours in program 6 Codewheet2pos 0 1 2 s 4 5 6 ffel Program 8 and 9 Constant rotation clockwise Constant rotation counter clockwise In programs 8 and 9 the speeds are equivalent to RPM sO 0 2 0 4 0 6 0 8 10 12 15 201 3 0 16 FL 75 XT 2 B C and F User Manual Trouble shooting Symptom Cause Solution Is the power ON Turn ON the power Is the supply fuse intact Replace the fuse Is the power cord properly Reinsert the power cord connected No light Check with the installation instructions Let it cool off for approx 15 minutes and try again Is the lamp blown Replace the lamp No light Is the light generator too hot while Check with the installation fan running operating instructions Is the light generator too hot I
11. s the fan blocked Clear the airways Light switches Is the fan mal functioning Replace the fan ON and OFF Is the lamp old Replace the lamp Is the lamp old Replace the lamp Clean the filters with a damp Are the filters dirty cloth Finish by wiping off The light output with a dry lint free cloth has diminished Clean the harness common Is the fiber harness common end end with a damp cloth dirty Finish by wiping off with a dry lint free cloth Warning Only a properly trained person should undertake the work of servicing other than the above mentioned 17 FL 75 XT 2 B F and C User Manual Spare parts Model designation Roblon item no Philios 12 V 75 W 3000 K 6512 7595 Sunon KDE 1208PTB3 6 6408 0124 7800 0140 7800 0141 7800 0142 7800 0143 CTC filter 1200K 7800 0148 CTC filter 900K 7800 0149 CTC filter 500K 7800 0147 Colour wheel Standard colour wheel 5100 0085 Dimmer wheel Standard dimmer wheel 5100 0086 ei Galvanized steel 0160 0365 Bracket Electronic ballast EU 230 240 V 6815 0020 US 120 11 8V 6810 5042 Dichroic colour filter mounted in bracket CTC filter with bracket Effect motor for DMX models Gear motor for Stepper motor 1 8 6400 4000 EU 1 rom 230 VAC 6400 1220 US 1 2 rom 110 VAC 6400 1215 DMX 512 LineBacker 0160 0300 control units Alcorn McBride 0160 0301 DMX 512 Splitter Y distributor in a DMX system 0160 0310 5 outputs en 0160 0325 control unit Cable betwe