Home
6150RF - GEOARM Security
Contents
1. Two 6150RFs are needed for this application one assigned to partition 1 and one assigned to partition 2 If using an RF keypad on only one partition the 6150RF s partition assignment in panel programming must match the partition If set for Local on a partition control the 6150RF s partition assignment must match the one programmed in the BD device An example of an installation using two 6150RF Keypad Transceivers with 2 Way Wireless Devices e g 5828V on Two Partitions is shown below 6150RF 1 CONTROL PANEL 2 6150RF Settings 6150RF 1 6150RF 2 Keypad Must be assigned to Must be assigned to Partition 1 in the Partition 2 in the control panel control panel House ID Match Partition 1 Match House ID in House ID in the Wireless Device control panel and House ID in Wireless Device House ID System Local Source Receiver On Off Enable Transmitter On On Enable PROGRAMMING THE 6150RF The 6150RF is shipped with pre programmed default values Later in these instructions are diagrams showing the wireless keys loops and their default functions Regardless of which wireless key you use even if it is one not shown loops 1 4 are defaulted for all eight devices as shown These values may be changed to suit the installation Entering Program Mode Press the 1 and 3 keys simultaneously for a few s
2. 3 in the Programming for an Installation Without Local Wireless Keys section TROUBLESHOOTING The following error messages cause the 6150RF to produce rapid beeps for 5 seconds The table below describes the error messages and the corrective actions Display Probable Cause Corrective Action Lb Low battery in the wireless 1 Replace the battery if the wireless key has a replaceable battery key 2 Replace the transmitter if the wireless key does not have a replaceable battery oc Open circuit Verify that the Data Out wire is connected properly 1C Incompatible connection Verify that the control panel is not a First Alert type control panel Check 09 OR 1 6150RF Receiver is not 1 Verify that the Data In wire is connected properly Check 100 RF communicating Receiver OR 2 Another device on the 2 Verify the wiring connections between the control and all other devices Check 10n RF keypad terminals is not Receiver communicating to the control panel E8 Too many RF zones Verify the number of transmitters programmed into the control panel programmed n receiver address programmed in VISTA control panel SPECIFICATIONS Physical 6 1 4 H x 4 7 8 Wx 1 D Voltage 158 75mm x 123 8mm x 25 4mm Current Wiring Refer to Wiring Table on page 2 Range 200 nominal Frequency 345 MHz Relay Sounder 12VDC Standby 80mA Backlighting on and Sounder on 105mA Normally Open 1A 28VDC Piezo electric fire alar
3. s not having a manufacturer s date stamp for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period in which case the shorter period shall apply Seller s obligation shall be limited to repairing or replacing at its option free of charge for materials or labor any product s which is proved not in compliance with Seller s specifications or proves defective in materials or workmanship under normal use and service Seller shall have no obligation under this Limited Warranty or otherwise if the product s is altered or improperly repaired or serviced by anyone other than Honeywell factory service Connection of any device s to a communicating bus of a Honeywell security system e g keypad bus polling loop other than those manufactured or approved by Honeywell shall void this warranty For warranty service return product s transportation prepaid to Honeywell Factory Service 165 Eileen Way Syosset New York 11791 THERE ARE NO WARRANTIES EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Seller does not represent that the p
4. that has its serial number programmed in the 6150RF already To delete the serial number press gt then press 9 and press again To exit without deleting the serial number press the key Press the key to continue Step Action Display 1 Enter the Program mode by pressing the 1 and 3 keys Alternately flashes oo and two dashes simultaneously for a few seconds within 30 seconds after applying power 2 Enter 5 Wireless Key Editing Enter the device number for the Flashes the device number and a hyphen Once the device number is entered alternately flashes d with the device number and the serial number Step Action Display To change any of the programming for the wireless key perform one of the following steps in the Programming for an Installation WITH Local Wireless Keys section e For the user code perform step 5 e For the loop functions perform steps 6 and 7 e For the on board relay assignment perform steps 8 to 10 Alternately flashes d with the device number and 4 When you have completed editing the wireless keys press the key twice to exit the Program mode The keypad will display the last number that was enrolled i e d3 Note Upon exiting the Program mode the 6150RF alternately flashes Ad the 2 digit keypad address and the 2 digit receiver address If either of these is incorrect repeat steps 1 through
5. Honeywell K4460 1V6 2 06 Rev B ADEMCO 6150RF Keypad Transceiver INSTALLATION AND SETUP GUIDE GENERAL INFORMATION The 6150RF Keypad Transceiver is a combination unit incorporating a normally open relay output and the functions of e 6150 Fixed Addressable Keypad e 5881M RF Receiver e 5800TM Transmitter Module The 6150RF Keypad Transceiver may be used on any control panel that supports the 6150 Keypad Wireless Features The 6150RF supports the following e 5828 5828V wireless keypads e Up to eight wireless keys locally programmed directly into 6150RF without occupying any zones supported by the control panel e Button type transmitters e g 5804 5804BD for local operation e A maximum of 16 transmitters programmed into any 5800 Series supported control panel e Wireless keys with high security e g 5804E e RF jam detection when the receiver is enabled e Low battery indications for the local wireless keys e A nominal range of 200 for the RF transmitters some transmitters have a shorter range e Wireless keys for control panels that do not support RF themselves such as 4110DL e Sends status signals Armed Ready etc to bi directional units such as 5804BDV and 5828 5828V UL The 5802 5802MN 5802MN2 5804 5804BD 5804BDV 5804E 5814 5816TEMP 5819 5819BRS 5819WHS 5828 5828V and 5850 transmitters are not intended for UL installations Programming Features e Auto Enroll mode for programm
6. all or electrical gang box 4 Connect the power and data wires from the control panel to the terminals on the 6150RF as indicated in the wiring table adjacent to Figure 2 5 Connect the wires for the relay output if used to the terminals on the 6150RF s PC board 6 Reattach the keypad to its case back Note Upon power up or exit of the Program Mode the 6150RF alternately flashes Ad and the 2 digit keypad address and the 2 digit receiver address on the display Press any key to display the system status NOTE TO REMOVE CASE BACK PUSH IN THE TWO MOUNTING SNAPS LOCATED ALONG THE BOTTOM OF THE KEYPAD AND LIFT UP LOCKING TAB Figure 1 Removing the 6150RF Case Back RETAINING SNAPS 6150 006 VO WIRING TABLE Keypad Control Panel Wire Color AG Data In Green Aux Pwr GND Black Aux Pwr Red yy Data Out Yellow Note NO normally Open and C common are the VY GANOC connections for the relay output 0 Co 6150RF 003 V2 Figure 2 6150RF Wiring Connections APPLICATION GUIDELINES Use the following guidelines when planning an installation e Local wireless keys wireless keys programmed directly into the 6150RF may be used regardless of whether the RF receiver in the 6150RF is enabled or disabled e If using bi directional devices be sure to enable the transmitter modu
7. econds within 30 seconds after applying power The keypad beeps three 3 times and two dashes and two zeroes flash alternately in the upper left hand corner of the display If any other numbers or letters flash in the display press the PK key Note The keypad will not enter programming mode if the system has been armed before the 6150RF was powered up or down AY Programming Operations Once you have entered the Program mode you may move to any program address simply by entering the program address number The 6150RF will automatically exit the Program mode if no keys are pressed for 90 seconds While in the Program mode Pressing the 1 and 8 keys 30 seconds or more after applying power allows you to enter the User mode This mode allows you to enable and disable individual local wireless keys useful if e g a user accidentally loses a wireless key Refer to the User Guide for instructions e Pressing the key stores the information displayed then moves you to the next prompt and the keypad beeps twice e Pressing the key erases the current information and moves you back so you may enter the correct information Enter a program address e g press 1 for Keypad Address 2 for Receiver Address to set the parameters in the 6150RF The following chart lists the program addresses the keypad display and the choices Para Description Display Ch
8. ed in control panel 99 7 VISTA 10SE VIA 30PSE 7 n VISTA 10P VISTA 15P VISTA 20P VISTA 20SE HW Manually Start a Relay Action 8 VISTA 10SE VIA 30PSE 8 n VISTA 10P VISTA 15P VISTA 20P VISTA 20SE HW Manually Stop a Relay Action Activate Relay as Programmed in Control 71 VISTA 40 VISTA 5OP VISTA 128B Activate Relay as Programmed in Control 72 VISTA 40 VISTA 5OP VISTA 128B Activate Access Control Relay for 0 VISTA 40 VISTA 50P VISTA Partition 128B n Device Number programmed in panel to be controlled Press the K key Default Loop Functions Loop 4 Arm STAY Disarm Loop 1 Close on board relay for 2 seconds Loop 2 Disarm Loop 4 Arm STAY Loop 1 Close on board relay for 2 seconds Loop 3 Arm AWAY SET HOUSE CODE 5804BD 5804BDV NOTE If the loop is defaulted with a function e g Arm Disarm and also is assigned to activate the on board relay the system performs BOTH functions Repeat step 6 for the rest of the loops of the wireless key To program a button on the wireless key to control the on board relay enter 5 On Board Relay Assignment Flashes o Enter the loop number of the wireless key 1 4 Enter the relay action 0 no action 1 relay off 2 relay on 3 relay toggles on and off 4 relay closes for 2 seconds Note The relay action must be 0 for UL i
9. flashes the device number and a hyphen If you accept the serial number the 6150RF beeps two times If you If you reject the serial number the display reject the serial number the 6150RF beeps once and returns to the flashes d with the device number followed by enroll serial number prompt _ four times Note A maximum of 8 wireless keys may be enrolled into the 6150RF These wireless keys DO NOT occupy any zones supported by the control If you are finished programming for now press to exit Otherwise continue with step 5 5 Enter 2 User Code Enter the 4 digit user code for the wireless Flashes u4 Once the 4 digit user code is key entered the display flashes u4 the first two Note The user code must be a valid code that is programmed in the digits and then the last two digits of the user control panel code Press the x key to accept the user code If you are finished programming for now press to exit Otherwise continue with step 6 6 Enter 4 Loop Functions Enter the loop number 1 4 Flashes Ln Once the loop number is entered alternately flashes L with the loop number and the present function Step Action Display 6 Cont d Wireless Key Function Chart Function Entry Disarming Arming Away Arming Stay Arming Maximum Away Instant N BR OO PO Arming Instant Panic Alarm Produces type of alarm amp programm
10. ing wireless keys e Provides a method for deleting a serial number and re enrolling a new one in its place e Provides default settings for the wireless key functions Additional Features e Operates the on board relay in conjunction with the receiver e g to trip a garage door opener UL This feature is not intended for UL installations e Activates relays programmed into the control panel e Provides an End User mode to enable disable local wireless keys e g if a user accidentally loses a wireless key Refer to the 6150RF User Guide for this procedure INSTALLING THE 6150RF Locate the 6150RF in an area and at a height where it is convenient for user operation The 6150RF must be at least 10 feet from the control panel to ensure proper operation of the RF receiver Perform the following steps to install the 6150RF 1 Push the two case release snaps at the bottom of the keypad with the blade of a medium screwdriver this will push in the release snap then pull that side of the case back away Insert the screwdriver in the side of the keypad between the front and back case and gently twist to release the side locking tab Repeat for the other side Refer to Figure 1 for location of the case back release snaps and locking tabs 2 Route the wiring from the control panel through the opening in the case back See the control panel s instructions for proper wire run lengths 3 Mount the case back directly to a w
11. le in the 6150RF e If transmitters are programmed into the control panel be sure to enable the receiver Make sure you do not exceed the number of receivers supported by the control panel e Ifa local wireless key is programmed to arm disarm or to trigger a relay on the control panel a user code must be entered into the 6150RF This user code must also be programmed into the control panel e You must set the House ID only if you are using RF keypads and or bi directional devices AND the House ID Source is the 6150RF Local 6150RF Application Guide The following guide outlines how to program the wireless keys RF receiver and the House ID in the 6150RF for your installation Are you using RF keys RF receivers RF keypads and or _ Program System Control Panel beyond beyond Bi directional Wireless Keys system s system s devices on more Into Receiver House ID capacity capacity than 1 partition Enable Source 4110DL 4110XM 4140XMP 6150RF Local 0 VISTA 20OHWSE VISTA 10P VISTA 10SE VISTA System System 1 15 VISTA 15P VIA 30PSE 6150RF System 1 6150RF Local 0 VISTA 20SE VISTA 20P System ON 1 System 1 6150RF ON 1 System 1 6150RF OFF 0 Local 0 System OFF 0 Local 0 6150RF OFF 0 Local 0 VISTA 40 VISTA 5OP VISTA System ON 1 System 1 128B VISTA 128BP 6150RF ON 1 System 1 6150RF OFF 0 Local 0 System OFF 0 Local 0 6150RF OFF 0 Local 0 6150RF Programming Options
12. m is loud pulsing tone burglary audible panic alarm is two tone sound FOR DETAILS ON THE LIMITATIONS OF THE ENTIRE ALARM SYSTEM REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FEDERAL COMMUNICATIONS COMMISSION FCC Part 15 STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use The FCC requires the following statement for your information This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manu facturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correc
13. nstallations Press the key Flashing o and the loop number Once the action is entered displays o and alternately flashes the loop number and the relay action 10 Repeat step 9 for the rest of the loops 11 When all loops have been programmed for the wireless key press the key Flashes d followed by the device number 12 The 6150RF automatically displays the next available device number one that does not have a serial number If you want to program additional wireless keys repeat steps 3 through 10 Otherwise press the key This takes you back to the main display which alternately flashes oo and 13 Enter 0 High Security Mode To put the system into High Security mode enter 1 Enter 0 to disable Flashes En and 0 alternately OR En and 1 if the keypad is in high security mode 14 Press x to exit the 6150RF Program mode Note Upon exiting the Program mode the 6150RF alternately flashes Ad the 2 digit keypad address and the 2 digit receiver address If either of these is incorrect repeat steps 1 through 3 in the Programming for an Installation Without Local Wireless Keys section Deleting Replacing or Editing Wireless Keys Use the following procedure to delete replace or change any of the programming for a wireless key wireless key you want to edit This must be a device
14. oices Default 1 Keypad Address cA 01 31 31 2 Receiver Address rA 00 30 00 3 House ID HI 01 31 10 4 House ID Source hs 1 System 1 System 0 Local 5 Wireless Key Editing d Enter Existing Device Number 6 Receiver Enable rE 1 On 0 Off 1 Enable 7 Transmitter Module Enable tE 1 On 0 Off 1 Enable 8 Wireless Key Auto Enroll d Enter Serial Number 8 then 2 Wireless Key User Code u4 Enter 4 Digit User Code 8 then 4 Wireless Key Loop Function Ln Enter Loop Number then Function Loop 2 1 Disarm See Wireless Key Function Chart Loop3 2 Arm Away Loop 4 3 Arm Stay 8 then 5 Wireless Key On Board Relay O Enter Loop Number then Relay Loop 1 Close for 2 Seconds Assignment Action 9 Restore Defaults EE 1 Restores Defaults Any Other Key Does Not Restore Defaults 0 High Security Modet En 1 Enable 0 Disable 0 Disable The keypad will display the next number that can be enrolled i e d3 Jf t When operating the system in High Security mode non encrypted wireless keys will not function Defaulting the 6150RF To restore the 6150RF to the default values perform the following steps Step Action 1 Enter the Program mode by pressing the 1 and 3 keys simultaneously for a few seconds within 30 seconds after applying power The keypad alternately flashes oo and two dashes Press the 9 key The display flashes EE Press the 1 key to restore the default values or press any other key to exit with
15. out restoring the default values If you pressed 1 the keypad beeps three 3 times and returns to alternately flashing oo and two dashes If you pressed any other key the keypad will beep two 2 times and return to alternately flashing oo and two dashes 4 Press to exit the 6150RF Program mode Programming Procedure This section is divided into two parts e Programming for an installation WITHOUT local wireless keys e Programming for an installation WITH local wireless keys Using the programming procedure WITH local wireless keys is necessary only if you plan to use wireless keys beyond the control panel s capacity or on a system that does not support 5800 Series wireless Refer to the 6150RF Application Guide on page 1 for installations that require these settings Note See the control panel s installation instructions for the acceptable keypad and receiver addresses iy f If you are using a wireless key in High Security mode 5804E in the control panel it will occupy one of the devices in the 6150RF A Programming for an Installation WITHOUT Local Wireless Keys To program the 6150RF for an installation without any local wireless keys perform the following steps Step Action Display I Enter the Program mode by pressing the 1 and 3 keys Alternately flashes oo and two dashes simultaneously for a few seconds within 30 seconds after applying power or within 30 seconds afte
16. r removing the case back 2 Enter 1 Keypad Address Enter the 2 digit keypad address 01 31 Alternately flashes cA and the 2 digit keypad Press the x key to continue address 3 Enter 2 Receiver Address Enter the 2 digit receiver address 00 30 Alternately flashes rA and the 2 digit receiver Press the x key to continue address 4 Enter 4 House ID Source Enter 1 System to use the House ID Alternately flashes hS and either 1 or 0 programmed into the control panel if RF keypad s and or bi directional device s e Are used on the control panel OR e Neither is used Enter 0 Local to use the House ID programmed into the 6150RF Program Address 3 Note If the House ID Source is e System 1 RF keypad and bi directional units MUST match the House ID programmed into the control panel e Local 0 RF keypad and bi directional units MUST match the House ID programmed into the 6150RF Press the key to continue 5 Enter 6 Receiver Enable Enter 1 to enable or 0 to disable Alternately flashes rE and either 1 or 0 Enable the receiver if RF transmitters or wireless keypads are programmed into the control Note Make sure the number of receivers set for Enable 1 does not exceed the capacity of the control panel Press the key to continue 6 Enter 7 Transmitter Module Enable Enter 1 to enable or 0 to Alternately flashes tE and ei
17. roduct s it sells may not be compromised or circumvented that the product s will prevent any personal injury or property loss by burglary robbery fire or otherwise or that the product s will in all cases provide adequate warning or protection Customer understands that a properly installed and maintained alarm system may only reduce the risk of a burglary robbery fire or other events occurring without providing an alarm but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result CONSEQUENTLY SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THAT THE PRODUCT S FAILED TO GIVE WARNING HOWEVER IF SELLER IS HELD LIABLE WHETHER DIRECTLY OR INDIRECTLY FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE REGARDLESS OF CAUSE OR ORIGIN SELLER S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT S WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER This warranty replaces any previous warranties and is the only warranty made by Seller on this product s No increase or alteration written or verbal of the obligations of this Limited Warranty is authorized 165 Eileen Way Syosset New York 11791 WAIANAE FORME WEN cr otis rerersei menarane K4460 1V6 2 06 RevB www honeywell com security
18. t the interference by one or more of the following measures If using an indoor antenna have a quality outdoor antenna installed Reorient the receiving antenna until interference is reduced or eliminated Move the radio or television receiver away from the receiver control Move the antenna leads away from any wire runs to the receiver control Plug the receiver control into a different outlet so that it and the radio or television receiver are on different branch circuits If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user or installer may find the following booklet prepared by the Federal Communications Commission helpful Interference Handbook This booklet is available from the U S Government Printing Office Washington DC 20402 The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the equipment LIMITED WARRANTY Honeywell International Inc acting through its Security amp Custom Electronics business Seller 165 Eileen Way Syosset New York 11791 warrants its product s to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the product s or for product
19. ther 1 or 0 disable Enter 1 if bi directional devices are being used Note If the House ID Source is System and more than one 6150RF is used make sure each of the keypads have the Transmitter Module enabled See Note under House ID Source step 4 Press the key sAn Step Action Display Enter 0 High Security Mode To put the system into High Security mode enter 1 Enter 0 to disable En 8 Press the x key to exit the 6150RF Program mode READY or NOT READY Note This is all the 6150RF programming necessary for this application Upon exiting the Program mode the 6150RF alternately flashes Ad the 2 digit keypad address and the 2 digit receiver address If either of these is incorrect repeat steps 1 through 3 Programming for an Installation WITH Local Wireless Keys y A f e The 6150RF is supplied with default settings for the functions of the wireless keys See page 3 e If during the programming of the wireless keys you make a wrong entry and want to reprogram a wireless key simply press the key then enter the correct information Perform steps 1 6 in the Programming for an Installation Without Local Wireless Keys section Then perform the following steps Note The 6150RF is shipped with the loop functions pre programmed Perform steps 6 through 10 only if it is necessary to change any of the loop func
20. tions Loop 1 Close the 6150RF On Board Relay for 2 sec Loop 2 1 Disarm Loop 3 2 Arm Away Loop 4 3 Arm Stay See the Wireless Key Function Chart below for the choices Entering a number other than the one specified may give unpredictable results Step Action Display 1 Enter 3 House ID Enter the 2 digit House ID for the 6150RF 01 Alternately flashes hl and a 2 digit number 31 Note The House ID is needed only if RF keypads and or bi directional units are used and House ID source is set for Local The House ID entered here MUST match the House ID programmed in the RF keypad and the bi directional unit Press the key to continue 2 Enter 8 Wireless Key Auto Enroll The 6150RF automatically Flashes d with the next available device advances to first available device number number followed by four times and then Note If all 8 devices have been enrolled the 6150RF beeps three times repeats the sequence and continues to alternately flash oo and 3 Press any button on the wireless key to enroll the serial number The Alternately flashes d with the device number keypad will beep three times and the serial number Note If enrolling a wireless key 6804E in high security mode press all four buttons on the wireless key simultaneously 4 Press the key to accept the serial number OR press the key to If you accept the serial number the display reject the serial number
Download Pdf Manuals
Related Search
Related Contents
Formatage PDF SERVICE MANUAL Panamax M4LT-EX surge protector SCD エクスプレス Manual de Instrucciones Product details Statistical Viewer: a tool to upload and integrate linkage and Copyright © All rights reserved.
Failed to retrieve file