1. ver 1 3 DIGITAL THERMOSTAT USER MANUAL Temporary temperature override To temporary override the current set temperature 1 Press Ay or Lv button once the set temperature starts flashing 2 Press Aj or v button again to adjust the set temperature 3 Wait for 5 seconds to confirm the setting with OVERRIDE shown on LCD Now your thermostat will maintain the new set temperature until the next setpoint To cancel the override setting press and hold button for 5 seconds until OVERRIDE disappear Vacation mode To set vacation mode press and hold the aj button for 3 seconds until E3 appears Use same procedure to exit this mode Vacation mode will maintain a set temperature default 10 C all the time Press A or Lv button to change the set point and wait for 5 seconds to accept and exit STEP 1 Carefully separate the front half STEP 2 of the thermostat from the back plate by placing a small flat head terminal driver into the slots on the bottom face of the thermostat Carefully unplug the ribbon connector which is plugged in to the front half of the thermostat STEP 3 Place the thermostat front half STEP 4 screw the thermostat back plate somewhere safe Terminate the on to the back box thermostat as shown in the diagrams below Wiring Diagram STEP 5 Re connect the thermostat ribbon ca
2. R AF AF model only This gives option to choose to show air temperature floor temperature or A to show air temperature F to show floor TR Temperature readout to show both floor amp air in interval temperature A F to show both in 5 second intervals Please Note It is faster to program the same schedule for the entire week and then to adjust the exceptional days To erase program 2 and 3 for Saturday and Sunday see below In step 1 select Saturday or Sunday 07 MAXFT set maximum This is to protect the floor surface 40 degree default In step 4 instead of using up or down button using button s will erase the time HOOP TEIN IMAP MONEY In step 6 instead of using up or down button using button ko will erase the time 08 Clock format This is to set the backlight turning on time User can also set the backlight 30 seconds default On always on OFF always off always on or off Set the Time and Day 09 TF temperature format This alows users to select between C or F C or F This thermostat is fitted with a real time clock It is essential that the clock time and day are set accurately if you require your programmed events to start on time Follow the easy steps on the next page 10 Clock 12 24 hour clock system selection 24 default 12 hour or 24 hour clock system Step 1 Press the button B and the time will flash Step 3 Press button E3 again the day of the week will flash 1 FP Frost protection This is to avoi
3. ble and clip the two FEED halves together AINAN IIRA Floor Sensor Dimensions _ Somm 7 os g 3 CS H This product should be U gt j H oo A installed by a qualified N 2 1 electrician 86mm Warm 01268 567019 ver 1 3 DIGITAL THERMOSTAT A USER MANUAL A Symbols Optional Remote Controller Buttons Description Optional Remote Controller Turning on off the thermostat Remote control model only een 2 1 The buttons are locked 1 Turn on off thermostat 2 Confirm setting oc B VENU 3 4 5 3 Program button Heating is turned on 4 Lock or unlock buttons 9 5 Menu in OFF mode pav TIME 6 ie 8 HEARS 6 Set Day Room temperature Sse p 8 Auto Manual selection FT E CD 9 View floor temp AF model only FT Floor temperature 10 Cancel override 3 10 1 11 Vacation mode 12 Decrease the set value gv A AUTO Automatic mode executes the 13 Increase the set value 12 13 programmed schedules Decrease a Temporary temperature override zx Ti Program The program number Comfort temperature mode Economy temperature mode Vacation temperature mode Frost protection activated Increase b a B O e E A Press Oj buttton to Turn on off the thermostat When thermostat is turned off the LCD will only display current temperature reading When the thermostat is turned off pre
4. d room temperature goes below 5 C on activated off deactivated Step 2 Use up or down button to change the time Step 4 Use up or down button to change the day of the week 12 SC setpoint configuration This allows user to select between 2 sets of default programmed set points 4 means the 4 programmes will have 4 independent set Hold up or down button to change by 15 minutes each time Se Auto Manual Mode Please Note one of the following error messages will appear if one of these problems occur LO This error means that the room or floor temperature is below 0 C HI This error means that the room or floor temperature is greater than 50 C If the floor sensor is short circuit or broken the LCD will display ERR and the thermostat will cut off output This product should be installed by a qualified electrician temperatures Each set temperature can be different to the others program 3 set temperature in program 2 equals the set temperature in program 4 If set temp in program 1 is changed set temp in program 3temp in program 2 is changed set temp in program 4 will be changed will be changed automatically to the same set temp as program 1 If set automatically to the same set temp as program 2 Press button M to select Auto Manual mode In Manual mode the thermostat maintains a constant set temperature manually set by the user In Auto mode the thermostat executes the pre programmed schedules To adjust these sc
5. hedules follow the easy steps below Warm 01268 567019 Step 5 Press button E3 again to accept and exit Resetting factory defaults Your thermostat has the ability to reset all settings to the factory defaults If you are certain you want to do this In standby mode when thermostat is turned off press and hold button M and E3 for 5 seconds until RESET is shown for 5 seconds on LCD Lock the buttons To lock the buttons press and hold the aj and Lv buttons for 3 seconds until you see a lock icon E appearing to unlock repeat the steps above View floor temperature If thermostat is set in AF model and set to show air temperature only press and hold the down button for 3 seconds floor temperature will show and it will automatically revert back to air temperature in 5 seconds Warm 01268 567019
6. ss and hold button M for 3 seconds to bring up a configuration menu In this mode press button M to select different features setting General Settings For a more in depth description of the menu features please see overleaf Warm 01268 567019 ver 1 3 DIGITAL THERMOSTAT USER MANUAL ver 1 3 DIGITAL THERMOSTAT A USER MANUAL Menu 01 Features description Model Model Selection Features Explanation This thermostat is a combination model allowing you to choose between 3 different models A AF and F model A model air only with built in sensor AF model air amp floor with both built in and remote sensor F Adjustment press up or down button to adjust A AF F Program your thermostat le Press and hold button M for 5 seconds until PROG is shown with the Day flashing Use up or down button adjust the day hold up or down button for 5 seconds to set all days the same Press button M to bring up the program 1 E Use up or 6 Press button M to bring up the program 3 Ee Use up or down button to set the start time default 16 30 Hold up or down button to change by 15 minutes each time fa model floor only with remote sensor l d down button to set the start time default 07 00 Hold up or Press button M again and use up or down button to set the desired temperature to be maintained for program 3 02 Sd switching differential The numbers of degree difference before s
7. witching The default is 1 C 1 1 degree default 2 2 degrees down button to change by 15 minutes each time default 22 C ue which means the thermostat will switch the heating on 0 5 C below the 3 Press button M again and use up or down button to set the i o g Program ET AE desid temperature t0 be maintained for program 1 3 Press buton M to bring up the program 4 EE Use upor and will switch off 1 C above the set temperature default 22 C down button to set the start time default 22 30 Hold up or down button to change by 15 minutes each time _ l l l 4 Press button M to bring up the program 2 Ee Use up 03 ATC air temp calibrate This is to calibrate air temperature if required 1 decrease 1 degree 1 increase 1 degree or down button to set the start time default 09 30 Hold up 9 Press button M again and use up or down button to set the Bo l or down button to change by 15 minutes each time desired temperature to be maintained for program 4 default 04 FTC floor temp calibrate This is to calibrate floor temperature if required 1 decrease 1 degree 1 increase 1 degree 16 C 5 Press button M again and use up or down button to set the 05 Maximum floor temperature This is to protect the floor surface by limit the floor temp AF model only 9S 10s 15s 20s default 25s 30s desired temperature to be maintained for program 2 10 Press button M to accept and exit _ default 16 C 06 T

Download Pdf Manuals

image

Related Search

Related Contents

MultiRAE MX User`s Guide  Origin Storage DELL-1000SH/5-NB62 hard disk drive  WARNING CAUTION - Pajero 4WD Club of Victoria Public Forum  BTP-R180II User`s Manual V1.0  Mercedes Benz R230 User's Manual  Instruction Manual  Toastmaster T2000W User's Manual  TP-LINK TL-SG1008D + TG-5269 network switch  Logical Expressions: Analyzing, Generalizing, Rewriting  Panduit pdf LS3E User`s Manual  