Home
PJ Network Manager for Windows
Contents
1. 15 Setting commands batch processing for multiple targets 15 Setting timer for targets 16 Setting up default setting 17 Customizing the status list 19 Viewing the alert information 22 Viewing the event log 23 Description of Event Type Warning column Warning value 24 About event treatment 26 Viewing the command history 27 Storing the management file 28 Information saved to the registry
2. 28 Registering the target information from the defined file at once 29 Format of the defined file 30 Example of the defined file 30 Login to the target equipment 31 Contents 3 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Introducing This PJ Network Manager is a SNMP manager software for the network equipment which supports the private MIB Management Information Base By installing the PJ Network Manager to the computer you can monitor the equipment simply such as the projector the projection monitor and the flat display monitor connect ed to the network The PJ Network Manager can handle our products which has a SNMP agent function SNMP SNMP is an abbreviation for Simple Network Management Protocol On the TCP IP network it is the protocol to monitor and control the equipment connected to the network SNMP realizes the management function by reading and changing the management infor mation called MIB with SNMP protocol between the manager management equipment and agent controlled equipment which are connected wi
3. 11 Editing the target 11 Deletion of the target 11 Setting up the warning value 12 Starting target monitoring 12 When happens the alert on the target 13 When happens the trap event on the target 13 What s Trap 13 Stopping monitoring the target 14 Displaying all the status information of the target 14 Setting the target group 14 Setting up the password of Telnet
4. Information of the input source RGB VIDEO S VIDEO NETWORK etc Network status Condition of the network mode Off line Network Viewer Network Capture Audio system Displays audio system mode NORMAL PERSONAL MUSIC TALK Volume Sound Volume of the network equipment Treble Sound treble of the network equipment Bass Sound bass of the network equipment Balance Sound balance of the network equipment Mute Sound mute status of the network equipment ON OFF Power management Power management status of the network equipment OFF READY SHUTDOWN Monitor out Monitor out status of the network equipment ON OFF Shutter No show Shutter status of the network equipment OFF High Contrast Normal Shutter management Shutter management status of the network equipment Shutdown Fan control Fan control status of the network equipment Normal Maximum OFF On1 etc Inside Temperature A Displays inside temperature A of the equipment in Centigrade or Fahrenheit Inside Temperature B Displays inside temperature B of the equipment in Centigrade or Fahrenhe
5. 5 PJ Network Manager installation 6 PJ Network Manager un installation 6 Chapter 3 Basic Operation 7 Launching and quitting PJ Network Manager 8 Name of status window 8 Quitting PJ Network Manager 9 Menu tree 9 What s Target 9 Name of the button on the tool bar 10 Icon display for the target 10 Addition of the target
6. Type of the Event See table on the next page Warning column Warning column of the Event See table on the next page Warning value Warning value of the Event See table on the next page Unit Displays unit of the warning value Event log information items The listed items are fixed The order of the event log list can be changed temporarily by clicking the column name which you want to sort It switches ascending or descending order by clicking the column name each time Column width can be changed by dragging the right edge of the column The column order can be changed with drag and drop the column Column cannot be deleted Viewing the event log 24 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Chapter 3 Basic Operation 1 When PJ Network Manager could not send mail or acquire the memory no message is displayed in Warning column and Warning value For further details of each warning column and value refer to the next page Description of Event Type Warning column Warning value Event Type Warning Column Warning Value Description ALERT ON Abnormality has happened OFF Abnormality has been cleared Connect Un connected Connected Acquisition error Refer to the next page Power status PowerFailure TemperatureError Normal AfterTempError RS232CFailure Power management Shutter management LampFailure Normal Standby Normal
7. Shanghai ph 86 21 6278 7708 Beijing ph 86 10 6561 0240 Korea ph 82 2 702 1601 Japan ph 81 3 3599 7481 Corporate offi ces Worldwide offi ces
8. To remove the PJ Network Manager software from your computer perform it with Add amp Remove Programs on the control panel In case of Windows Vista or Windows 7 use Programs and Features from the control panel PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 7 Chapter 3 Basic Operation 3 8 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Chapter 3 Basic Operation Launching and quitting PJ Network Manager To launch PJ Network Manager take one of the following Select PJ Network Manager from the menu Start All programs Double click a management file 1 Tool bar Menu Status list Status bar Polling times indication Event indication Items Description Menu Executes a command with menu selection Tool bar Executes a command assigned to a button Target Network equipment for monitoring Status bar Indicates the status of PJ Network Manager and explaining the command selected with cursor Status list Indicates the status of targets monitoring When some errors are detected the target name icon and error items are indicated with red Status column Column of status list Polling times indication Indicates the times of polling during the monitoring Event indication Indicates the event ALERT T
9. The listed items are fixed Column width can be changed by dragging the right edge of the column The column order can be changed with drag and drop the column Column cannot be deleted Up to 1000 of events can be stored If it exceeds 1000 events the oldest event is deleted and the latest event is added Command history Items Description Executed date time Executed date and time of the command Target name Name of the network equipment IP address IP address of the network equipment Command Type of the Command Detailed data Contents of the Command Result Results of the Command About event treatment 28 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Chapter 3 Basic Operation Information saved to the registry Following application setting information is saved to the registry of your computer So the setting condition is memorized even after quitting the application Items Description Status window information Display position and size of the status list window Status list information Display status column column width and column order Event log list information Column width and order of the event log list Font set up Font setting value Type face size and style Storing the management file When you monitor the network equipment with the PJ Network Manager you can save the regis
10. OnStartingUp Normal OnCoolingDown Normal PowerOn TemperatureError OnCoolingDown Power management OnCoolingDown Shutter management OnCoolingDown LampFailure OnCoolingDown Input status SignalsInterrupted SignalsInputted Inside Temperature status A to C External Temperature status Abnormal Lamp status 1 to 4 Failure Replace Lamp time 1 to 4 setting time Filter status Clogged Warning Filter time setting time TRAP LampFailure Lamp status 1 to 4 Failure LampReplace Replace PowerOFF PowreFailure PowerManagement ShutterManagement Power status Normal Standby Normal OnCoolingDown PowerFailure Power management Power management OnCoolingDown ShutterManagement ShutterManagement OnCoolingDown TemperatureError Inside Temperature status A to C External Temperature status Abnormal SignalIsInterrupted Input status SignalIsInterrupted LampReplacementTime Lamp time 1 4 lamp time FilterReplacementTime Filter time filter time CloggedFilterWarning Filter status Clogged Warning AutoPlayError n a Error WarningOnConstantModeForBr ightness n a n a SYSERR Mail Transfer MemoryError n a 1 n a 1 25 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 The column order and width of the event log window are saved to the registry of the computer Up to 1000 of events can be stored If it exceeds 1000 events the oldest event is deleted and the latest e
11. Rev 1 01 2011 Login to the target equipment After double clicking the target name on the status list the computer launches web browser and displays the login window of the target equipment You can control and set up the projector remotely by using the web browser For the fur ther information of instruction see the separated network owner s manual Login by dou ble clicking An example of the login page Login to the target equipment PJ Network Manager for Windows PM KH2K Canada Christie Digital Systems Canada Inc 809 Wellington St N Kitchener Ontario N2G 4Y7 PH 519 744 8005 FX 519 749 3321 Customer Service 1 800 265 2171 sales canada christiedigital com USA Christie Digital Systems USA Inc 10550 Camden Drive Cypress CA 90630 PH 714 236 8610 FX 714 503 3375 Customer Service 1 866 880 4462 sales us christiedigital com United Kingdom Branch Office Christie Digital Systems Canada Inc ViewPoint 200 Ashville Way Wokingham Berkshire U K RG41 2PL PH 44 0 118 977 8000 FX 44 0 118 977 8100 sales europe christiedigital com Chile Representative Office Christie Digital Systems USA Inc Av Pedro Fontova 7619 of 60 Santiago PH 56 2 721 11 75 Mobile 5699 436 6555 France Representative Office Christie Digital Systems Canada Inc B timent D Hall 4 Parc Louis Roche 96 114 Avenue Louis Roche F 92230 Gennevilliers France PH 33 0 1 41 21 44 04 FX 33 0 1 41 21 00 36 sales france
12. Un connected Drive time Accumulated use time of the equipment Power status Power status of the equipment Normal Power on Normal Standby Power Management Power failure lamp failure etc Input status Input signal status Signal No signal Signal interrupted Inside Temperature A status Status of inside temperature A Normal Warning Error Inside Temperature B status Status of inside temperature B Normal Warning Error Inside Temperature C status Status of inside temperature C Normal Error External Temperature status Status of external temperature Normal Warning Error Lamp1 status Status of Lamp1 Off On Error Replace Lamp2 status Status of Lamp2 Off On Error Replace Lamp3 status Status of Lamp3 Off On Error Replace Lamp4 status Status of Lamp4 Off On Error Replace Lamp1 time Used time of Lamp1 Lamp2 time Used time of Lamp2 Lamp3 time Used time of Lamp3 Lamp4 time Used time of Lamp4 Filter status Status of airfilter Normal Clogg
13. christiedigital com Germany Representative Office Christie Digital Systems Canada Inc Willicher Damm 129 D 41066 M nchengladbach PH 49 2161 664540 FX 49 2161 664546 sales germany christiedigital com Eastern Europe Representative Office Christie Digital Systems Canada Inc Regus Bank Centre Szabadsag ter 7 H 1054 Budapest Hungary PH 36 0 1 47 48 100 FX 36 0 1 47 48 452 sales europe christiedigital com Middle East Representative Office Christie Digital Systems Canada Inc C O Emirates Group Security Building C Block Room 207 208 209 Airport Free Zone PO Box 293762 Dubai UAE PH 971 0 4 299 7575 FX 971 0 4 299 8077 Spain Christie Authorized Reseller Antonio Abad Pol gono Industrial Ventorro Del Cano Esquina C Aldea del Fresno 3 3 Puerta Izqda 28925 Alcorc n Madrid PH 34 91 633 9990 FX 34 91 633 9991 Italy Christie Authorized Reseller Angelo Tacca Via Garibaldi 88 20024 Garbagnate Milanese MI PH 39 02 9902 1161 FX 39 02 9902 2641 Africa Representative Office Christie Digital Systems Canada Inc 4 Patricia Road Gillitts KwaZulu Natal 3610 Republic of South Africa PH 27 0 317 671 347 FX 27 0 317 671 347 MB 27 0 823 045 442 Singapore Branch Office Christie Digital Systems USA Inc 627A Aljunied Road 05 02 Biz Tech Centre Singapore 389842 PH 65 6877 8737 FX 65 6877 8747 sales singapore christiedigital com China Beijing Represent
14. column name each time Sort by clicking Drag to move column Drag to change column width Customizing the status list 22 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Chapter 3 Basic Operation Viewing the alert information 1 Click button on the tool bar The alert display window appears and the alert informa tion of all the targets which are having an alert is listed on this window as the below 2 To export the alert information as text file CSV file click Export button Column width can be changed with dragging the right edge of the column The column order can be changed with drag and drop the column Column can not be deleted 23 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Viewing the event log 1 Click button on the tool bar The event log display window appears and the events which have been happened on the targets are listed on this window as the below 2 To export these events as text file CSV file click Export button 3 To delete the event log select the accrual date item you intend to delete by clicking and then click Delete button On the confirmation dialog click Yes to execute deletion Items Description Accrual date Accrual date of the event Target name Name of the network equipment IP address IP address of the network equipment Event Type of the Event ALERT TRAP SYSERR See table on the next page Type
15. manual is Windows XP Professional and Internet Explorer 6 0 In case of another OS or Web browser some instruc tion procedures may differ from the actual operation depending on your computer envi ronment Use of this manual This manual does not provide the description of basic operation and functions for comput er web browser projector and network For instructions about each piece of equipment or application software please refer to the respective manual PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 5 Chapter 2 Set up 2 6 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Chapter 2 Set up PJ Network Manager installation 1 Set the supplied CD ROM into the CD ROM drive of your computer Double click SetupTool exe icon in the PJ Network Manager folder in the CD ROM 2 Select English United States from the pull down menu on the Choose Setup Language window and click OK button to start installing and then follow the installation wizards As the Software License Agreement will appear read contents carefully and click Yes button if you agree with the license agree ment to proceed with installing Note To install the software into the computer with Windows 2000 Windows XP Windows Vista or Windows 7 you should logon as administrator Before installation make sure that the other applications are closed otherwise proper installation cannot be made PJ Network Manager un installation
16. time The available setting items use time are depend ing on the target equipment 1 Select a target on the status list with right click When setting multiple targets together select targets with pressing Shift or Control key 2 Select Warning value setting on the popup menu The setting window will appear as the right figure 3 Check Warning time check box The setting items are activated Select a setting item and click Edit button Another setting window appears 4 Enter the threshold value of selected item and then click OK button The setting window will dis appear 5 Set up warning value for remaining items if avail able and then click OK button The setting win dow will disappear To disable the warning value clear Warning time check box When selecting multiple targets the value set to the lowest target on the status list is displayed as the current setting time Up to 99 999 hours can be set for the use time The warning value is stored in the management file Starting target monitoring 1 Click button on the tool bar to start monitoring the target 2 PJ Network Manager starts polling the target in a sequential from the top of the status list and displays the results on the status list Example of the set up window 13 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 What s Trap Trap is the event predefined by the SNMP agent If the predefined event When PJ lamp is off When internal PJ powe
17. ALERT Type ON Warning column Power status Warning value Power failure Sound warning alarm If the PJ Network Manager receives an event the computer beeps an alarm sound The alarm sound is depending on your computer sound setting The alarm sound is not made when your computer does not provide any speaker or the sound vol ume is muted Send e mail Following example message is sent to the e mail address you set up as the destination mail address Notes on using Windows XP Service Pack 2 SP2 Windows Vista Windows 7 Windows Firewall is turned on by default in Windows XP SP2 Windows Vista and Windows 7 Due to this Windows Firewall the send e mail function is not available When using this mail func tion you need to cancel the block for PJ Network Manager application For the further details of Windows Firewall see Windows help on your computer 27 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Display warning dialog Following dialog window appears on the screen if event occurs Viewing the command history 1 Click button on the tool bar Command history window appears and the command history is listed on the window as shown below 2 To export the command history as text file CSV file click Export button 3 To delete the command history select the item of Executed date time which you want to delete and then click Delete button On the confirmation dialog box click Yes button to execute deletion
18. Click Reference button and select a defined file to import the target information The imported target information will be listed on the target batch registration window If there is an error in the imported defined file the error information will be indicated on the Result column Retry importing after correcting the defined file 3 Click OK button to execute the registration Registering the target information from the defined file at once Target batch registration is not available during Target monitoring 30 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Chapter 3 Basic Operation Format of the defined file The defined file is a CSV data file created by the spreadsheet application and is defined as follows Column Description example Target name Name of target equipment Proj_01 Proj_03 PDP_01 etc IP address IP address 192 168 0 1 etc Community Name of SNMP community Default value of our network products is public Example of the defined file The table below shows the example of the defined file provided with the target informa tion Save this file as the CSV file Proj_01 192 168 0 1 public Proj_02 192 168 0 2 public Proj_03 192 168 0 3 public Proj_04 192 168 0 6 public Proj_05 192 168 0 7 public PDP_01 192 168 0 8 public FPD_10 192 168 0 9 public IP address Target name Community 31 PJ Network Manager for Windows 020 000366 01
19. LWU505 SNMP Manager Software U S E R M A N U A L 020 000366 01 PJ Network Manager for Windows This is the manual for the PJ Network Manager software This software is Windows compliant but non Mac compliant Read this manual thoroughly to operate the PJ Network Manager software First read the user s manual of the projector to understand the basic operation of the projector and the safety instructions The safety instructions in the user s manuals should be followed strictly User Manual SNMP Manager Software 2 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Contents 2 Chapter 1 Introducing 3 Introducing 3 SNMP 3 Trademarks 3 Operating Environment 4 Chapter 2 Set up
20. RAP SYSERR when the event happened Name of status window Status column 1 The file in which the Monitor target information and event log information are stored Refer to item Storing the management file p 28 for further details With double clicking the target name the web browser is launching and displays login window of the target p 31 Target 9 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Quitting PJ Network Manager To quit the PJ Network Manager click the close box on top right of the status window or select Exit from the File menu Note The PJ Network Manager cannot open multiple status windows at the same time Menu tree Menu Sub menu Operation File New Creates a new management file Open Opens an existing management file Save Saves the active management file Save As Saves the active management file with a new file name Exit Quits the application Target Target monitoring Starts or stops target monitoring Target addition Adds a new target Target information window will appear Target editing Edits selected target information Target deletion Deletes the selected target Group setting Groups the selected targets Warning value setting Sets up the warning value of the selected target Telnet setting Sets up the password of telnet Commands batch processing Sets commands batch processing for multiple selected targets Timer setting Sets up the timer for the sele
21. ative Office Christie Digital Systems USA Inc 7B15 Hanwei Plaza Guanghua Road Chaoyang District Beijing 100004 PH 86 10 6561 0240 FX 86 10 6561 0546 sales china christiedigital com China Shanghai Representative Office Christie Digital Systems USA Inc Room 1109 1116 Shartex Plaza No 88 Zun Yi South Road Shanghai 200336 PH 86 21 6278 7708 FX 86 21 6278 5816 sales china christiedigital com Japan Representative Office Christie Digital Systems USA Inc A bldg 2nd Floor Ariake Frontier Building 3 1 25 Ariake Koto ku Tokyo 135 0063 PH 81 3 3599 7481 FX 81 3 3599 7482 sales japan christiedigital com South Korea Representative Office Christie Digital Systems USA Inc 6F ILSIN Building 15 15 Yeouido dong Yeongdeungpo gu Seoul 150 872 South Korea PH 82 2 702 1601 FX 82 2 702 1602 India Representative Office Christie Digital Systems USA Inc Unit No 03 Navigator Building International Technology Park Whitefield Road Bangalore 560 066 India PH 080 41468941 48 FX 080 41468949 Americas Europe Middle East amp Africa Asia Pacific For the most current technical documentation please visit www christiedigital com USA Cypress ph 714 236 8610 Canada Kitchener ph 519 744 8005 United Kingdom ph 44 118 977 8000 Germany ph 49 2161 664540 France ph 33 0 1 41 21 44 04 Hungary Eastern Europe ph 36 0 1 47 48 100 Singapore ph 65 6877 8737
22. cted target System Target batch registration Imports target information defined with the external file System default setting Sets up the default setting monitoring information e mail informa tion Column selection Selects display items on the status list Font setting Sets up display font type and size on the status list Display Update Updates the information on the status list display Target display Displays selected target information Alert display Displays all of alert information on the status list Event log display Displays all the event logs Command history display Displays all of command history Tool bar Switches tool bar on or off Help Version information Displays version of software What s Target Target indicates the network equipment which provides an SNMP agent function Quitting PJ Network Manager 10 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Chapter 3 Basic Operation Name of the button on the tool bar The following commands are assigned to the buttons on the tool bar Button Operation New Creates a new management file Open Opens an existing management file Save Saves the active management file Target monitoring Starts or stops target monitoring Target display Displays selected target
23. e mail address of administrator Destination mail address Sets up the destination mail address when the event ALERT TRAP SYSERR happens on the target The mail address entering window appears when clicking Add button E mail information If Send e mail check box of Event reception process on Monitoring information is un checked the alert e mail will not be sent even if you set up the e mail address Up to 10 addresses can be set up for the destination mail address For the contents of the mail refer to item About event treatment p 26 19 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Customizing the status list Changing the status column indication 1 Select Column selection from System menu The col umn selection window will appear 2 On the window check the column name to be indi cated on the status list The mark next to the column name indicates alert item 3 To change the order of the display column on the status list select a column you intend to change the order and click To up or To down button 4 Click OK to close setting When specifying the column width by numeric value enter number 0 to 9999 onto Column width text box Column Description Target name Name of the network equipment Group Group name Connect Status of connection to the network Connected
24. ed Option Box filter status Status of option box filter Normal Error Clogged Filter time Use time of airfilter Option Box filter time Use time of option box filter The values in parentheses are typical value and they differ depending on the connected equipment The next to the column name indicates alert items Customizing the status list Specifies col umn width 20 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Chapter 3 Basic Operation Column Description Error info Error information Not available for the projector IP address IP address of the network equipment Community Community name of the network equipment public Introduction date 1 Date of the network equipment installed Timer Timer information Product info Name of the network equipment System name System name of the network equipment Proj_05 Contact Contact information of the network equipment Location Installed location of the network equipment Input signal Information of the input mode Input1 Input2 etc Input select
25. ems Description Execution date Sets up the Timer execution date everyday or a day Execution time Sets up the Timer execution time hh mm ss Action Sets up the events 17 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Setting up default setting The monitoring information and e mail information can be set up by the procedure below 1 Select System default setting from System menu The setting window will appear 2 Switch by clicking Monitoring information or E mail information tab for each setting Monitoring information Items Description Monitoring interval Sets up the interval of the polling in minute unit 1 to 99 minutes can be set Temperature unit Sets up the display temperature unit Centigrade or Fahrenheit Event reception process Sets up the treatment when the event ALERT TRAP SYSERR happens on the target For further information refer to the item About event treatment p 26 Sound warning alarm Send e mail Display warning dialog Monitoring information Setting up default setting 18 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Chapter 3 Basic Operation E mail information Items Description SMTP server Sets up the IP address of SMTP mail server or server host name Administrator s mail address Sets up the
26. ger for Windows 020 000366 01 Rev 1 01 2011 Chapter 3 Basic Operation Displaying all the status information of the target Select a target and click button on the tool bar The following status window appears and displays all the available status information of the target The target name and item which have an abnormality or connection error happen ing are indicated with red When PJ Network Manager cannot acquire the value of column information is displayed Stopping monitoring the target To stop monitoring the target click button again on the tool bar The projectors setting different network passwords cannot be set to the same group It is necessary for the projectors in the same group to set to the same password The above procedure can perform by selecting Target display from Display menu Setting the target group The target group can be set up by the procedure below When you set a command in the same group you set it 1 Select targets which you want to set from the status list Select Group setting from Target menu the dialog box will appear as the below figure 2 Select a group and then click OK button will not set the group 15 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Setting up the password of Telnet The password of telnet can be set up by the procedure below It is necessary to make a he password of telnet can be set up by the procedure below It is necessary to make a pass
27. information Alert display Displays all of alert information on the status list Event log display Displays all the event logs Command history display Displays all of the command history To switch the tool bar display on or off select Tool bar from Display menu New Save Target display Event log display Target monitoring Start Stop Open Alert display Icon display for the target Displays icon according to the target condition Icon Condition Flat display type Projector type Normal Abnormal condition One of the abnormalities Alert Trap or System error is happening on the target Connection error Target has been disconnected from the network Acquisition error Target has been disconnected from the network or does not provide SNMP function Unknown Target monitoring is not operating Command history display 11 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Addition of the target 1 Select Target Addition from Target menu The target information registering window appears 2 Enter target setup information and click Update button The information set on the target equipment are dis played on the system information items When the target equipment is not operating or it is not the monitoring equipment the error dialog Cannot obtain infor mation will appear 3 Click OK to close the window Repeat the above steps to register for o
28. it Inside Temperature C Displays inside temperature C of the equipment in Centigrade or Fahrenheit External Temperature Displays external temperature of the equipment in Centigrade or Fahrenheit Lamp mode Displays lamp mode 1 1 lamp mode 2 2 lamp mode 4 4 lamp mode etc Lamp control Displays lamp control mode Auto Normal Eco etc Model name Model name of the network equipment 1 Set up the installed date when the PJ Network Manager is newly introduced There are some un available columns depending on the products The value of un available col umn is displayed in blank or with 21 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Changing font Select Font setting from System menu The font setup window will appear Select your desired type face style and size on the window Customized font property is applied to all the windows of the setting To change order or width of the column Drag the status column name you want to change the order and move it on a new place and drop it To change column width set a mouse cursor onto the right edge of the col umn to change drag the mouse on it and adjust the column width Sorting the status list The order of the targets on the status list can be changed by clicking the column name which you want to sort It switches ascending or descending order by clicking the
29. put and Source Selects Input and Source Screen Sets up the screen size Resizes the picture screen Background Sets up the background Selects the background screen for when no input signal is Selects the background screen for when no input signal is detected Display Sets up the Display Decides whether to display On Screen Displays or not Shutter No show Sets up the Shutter No show Sets black out the image Lamp control Sets up the Lamp control Changes brightness of the screen Changes brightness of the screen Fan control Sets up the Fan control Chooses the running speed of cooling fans Setting timer for targets The timer information for targets can be set up by the procedure below 1 Choose a target which you want to set the timer Choose a target which you want to set the timer 2 Select Timer setting from Target menu Timer selection dialog box will appear as the as the below figure Check in a check box of an event to carry out 3 When you want to add events When you want to add events click Add button Input timer informations in Timer set ting dialog box and click OK button 4 Click OK button of Timer selection dialog box timers are set to the selected target When selecting multiple targets timers are set to all the selected targets Timer It
30. r circuit is failed etc happens target sends trap information to the SNMP manager When happens the alert on the target When happens the alert on the target If the abnormality or connection error happens on the target PJ Network Manager indi cates target name icon and status column item with red color to let you know the abnor mality When PJ Network Manager cannot acquire the MIB information of the target equipment it indi cates as Connection Error The interval of target monitoring is according to the setting of Monitoring interval on System default setting from System menu p 17 For the way to give notice of the alert information refer to Event reception process on System default setting from System menu p 17 When happens the trap event on the target During the target monitoring if the predefined event trap happens on the target equip ment the target sends the trap information to PJ Network Manager This trap information is displayed on the status list The trap information is set up in the SNMP setting items of the target equipment Projector has items such as When PJ lamp is off When the life span of lamp is reached When internal PJ power circuit is failed etc For further trap information refer to SNMP setting in the separated network owner s manual For the way to give notice of the trap information refer to Event reception process on System default setting from System menu p 17 14 PJ Network Mana
31. temperature was abnormally high Lamp status ON Failure Replace When the lamp is on When the lamp failed to ignite It reached lamp replacing time Lamp time lamp time It reached user setting lamp replacing time Filter status Clogged Warning Filter has been clogged Filter is close to clogging Filter time filter time It reached user setting filter time It reached user setting filter time Auto play error n a The error occurred during the auto image display WarningOnConstantModeFor Brightness n a The brightness Current value continuously goes down a cer tain rate from the value in Constant mode 26 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Chapter 3 Basic Operation About event treatment If the PJ Network Manager receives an event it executes following event treatment items which are selected in the system default setting Sound warning alarm Send e mail Display warning dialog For the further information of event type warning column and warning value see the item Viewing the event log p 23 The setting of event treatment refer to item Setting up default setting p 17 From Test1 lt admin abc xxx com gt management file name Date 2004 10 29 21 30 To user abc xxx com Subject Alert message Alert has occurred Accrual date 2004 10 29 21 13 42 Target name Proj_10 IP address 192 168 1 101 Event
32. tered target information system setting and event log information into the man agement file with a free file name It is useful if you manage multiple equipment in the net work Click button on the tool bar and save it with free file name The extension is pnm The management file contains following information Items Description Header Management file section file version System default setting Default value of the system setting Monitoring interval Event reception process Temperature unit E mail information Target information Information of the registered target Target information target name IP address Community Introduction date target MIB information Warning value set up Event log information Event log information ALERT TRAP SYSERR The maximum volume of a management file is required about 1MB Number of registrable targets is 200 number of events is 1000 29 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Registering the target information from the defined file at once The PJ Network Manager provides a function to import the target information from the defined file at once Prepare the defined file CSV data format in which the target informa tion is written along the format shown below 1 Select Target batch registration from System menu The target batch registration win dow appears 2
33. th TCP IP network Trademarks Microsoft Windows Windows 2000 Windows XP Windows Vista and Windows 7 are reg istered trademarks of Microsoft Corporation Macintosh is a registered trademark of Apple Inc in the USA and other countries Other products or brand names in this manual are reg istered trademarks or trademarks of their respective owners Unauthorized use of a part or whole of the contents in this manual is prohibited The contents of this manual are subject to change without notice Chapter 1 Introducing PJ1 PC6 PC4 PJ2 PJ3 PC5 SNMP Manager Trap Trap You received a trap PJ4 4 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Operating Environment Item Minimum Recommended CPU Pentium III 400MHz or higher Pentium 4 2 0GHz or higher for Windows XP Pentium 4 3 0GHz or higher for Windows Vista and Windows 7 Memory 128MB or higher 256MB or higher for Windows XP 1GB or higher for Windows Vista and Windows 7 HDD More than 20MB of free disk space Screen resolution SVGA 16 colors or more XGA True color or more LAN 10Mbps or more 100Mbps or more OS Windows 2000 Windows XP Windows Vista Windows 7 Windows XP Professional Windows Vista 32bit version Windows 7 32bit version Limited condition The number of agents monitored is up to 200 Chapter 1 Introducing Expression Abbreviation The OS of the computer and the Web browser described in this
34. ther equipment which is to be managed Editing the target 1 Select a target name to edit on the status list with right click 2 Select Target editing on the popup menu The target information window will appear and edit the contents then click OK button The system information cannot be edited Target editing can be executed by selecting Target editing from Target menu Deletion of the target 1 Select a target name to delete on the status list with right click 2 Select Target deletion on the popup menu The confirmation dialog will appear and click Yes button to execute deleting Target deletion can be executed by selecting Target deletion from Target menu It cannot perform the target addition editing and deletion during the target monitoring Up to 200 targets can be registered Up to 255 characters can be used for target name and community Items Description Name Enter a management name of the target equipment IP address Enter IP address of the target equipment Community Enter a community name in the network Default name is public System information Displays information set on the network equipment Addition of the target 12 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Chapter 3 Basic Operation Setting up the warning value PJ Network Manager provides a function to display the alert when the use time of the set ting item reaches a specified setting
35. vent is added The event log can be saved to the management file This Warning column is not available for some projector s model types Description of warning value The warning value with in the above table shows the event when the alert has cleared alert type is OFF Description of Event Type Warning column Warning value Warning Column Warning Value Description Connect Un connected Connected Acquisition error Projector has been disconnected from the network Projector has been connected to the network PJ Network Manager could not acquire the MIB information from the equipment Power status Power failure Projector turned off due to the power failure of the projector TemperatureError The projector turned off due to temperature error occurred Normal AfterTempError Normal after temperature error occurred RS232CFailure The RS 232C communication error occurred Power management The power management function turned projector lamp off Shutter management The shutter management function turned projector lamp off LampFailure The lamp failure occurred Normal Standby Projector turned into standby normally Normal OnCoolingDown On cooling down normally due to projector turned off Input signal status SignalsInterrupted SignalsInputted The signal was interrupted The signal was inputted again Inside Temperature status A to C External Temperature status Abnormal The projector turned off when the
36. word same as the network password 1 Select a target which you want to set up the password of telnet from the status list You can select multiple targets 2 Select Telnet setting from Target menu Telnet setting dialog box will appear as the below figure Set a password and click OK button When multiple targets are selected all the selected targets are set as the same password Setting up the password of Telnet The initial setting is 0000 Setting commands batch processing for multiple targets The commands batch processing for multiple targets can be set up by the procedure below 1 Select a target belonging to the batch processing group which you want to set and select Commands batch processing from Target menu Commands batch processing dialog box will appear as the below figure 2 Select a command which you want to set click Edit button Parameter editing dia log box will appear Select a parameter and then click OK button The check box of Commands batch processing dialog box will be checked 3 Click OK button The commands are carried out to all the targets of the same group The commands also work for the target which is not set to a group 16 PJ Network Manager for Windows 020 000366 01 Rev 1 01 2011 Chapter 3 Basic Operation Commands batch processing Available Command Items Description Power ON OFF Sets up the Power ON or Power OFF Input Source Sets up the In