Home

FPR-207 Fingerprint Reader User Manual

image

Contents

1. Chapter II Setting Short list of menu options Power on Hold key for 3s in standby interface authenticate administrator fingerprint in Verity Master interface if any administrator is registered and then enter management menu 0 9 are for setting key is for return and key is for confirmation 1 Finger fingerprint Notice ID number of 1 5 will be deemed as administrators by the system in default 1 Enroll FP _ input ID 1 Normal normal finger 2 Alarm alarm finger 2 Delete FP _ input ID 3 Browse C xxxxx number of fingerprints M xxxxx capacity of fingerprints FP xxxxxxxxxx browse fingerprint use UP and DOWN keys to change page and press Confirm to confirm operation 1 Enroll FP xxxxxxxxxx_ input ID 1 Normal normal finger 2 Alarm alarm finger 2 Delete FP xxxxxxxxxx_ input ID 4 Clear clear DEL ALL Fingers 2 Config configure 1 Number device number Number xxx 1 255 default 001 press Confirm to modify 2 Logic authenticating logic 1 ID FP ID card or fingerprint 2 ID FP ID card plus fingerprint 3 WG FMT Wiegand format 1 26 bit Wiegand 26 2 34 bit Wiegand 34 4 1 Tamper frequency of anti tamper Some model does not supply menu but the line function provides this Tamper Xxx 0 255 default 0 press Enter to modify 4 9 BUZ IN buzzer input Some model does not supply menu but the line function provides this 1 No 2 Yes User Manu
2. ID card fingerprint authentication ID card authentication fingerprint 4 3 Wiegand format setting WG FMT Select 3 WG FMT Press key and the screen hints as follows Select 1 26 bit to set the scanner to work under Wiegand 26 mode Select 2 34 bit to set the scanner to work under Wiegand 34 mode Note Explanation of standard WG26 WG34 definitions the maximum user ID is 16777216 under WG26 format and the maximum user ID is 4294967296 under WG34 format Please pay attention when the device is used with door access controller dd User Manual of FPR 207 Fingerprint Reader 4 4 1 Tamper freguency of anti tamper Some models do not supply this menu Tamper Xxx 0 255 default 0 press Enter to modify The purpose is to prevent against illegal tryout and comparison When illegal tryout reaches the set freguency 0 255 press Enter to set it is suggested to set to 20 in the device the device will suspend for 180s In this period the screen shows timing All the operations with the panel will not be available except for the exit button function 4 4 2 Buzzer input setting BUZ IN Some model does not supply menu but the line function provides this Enter the subdirectory and select 4 BUZ IN shown as follows Select 1 No which means no buzzer input Select 2 Yes which means buzzer input 4 5 Alarm ID setting ALM ID Select 5 ALM ID for alarm ID setting shown as follows ID 00000 00110 Enter
3. Please understand the minimum ID number of the door access controller connected when setting up user ID If the minimum allowable user ID is 100 for a certain door access controller the user ID registered at the scanner shall begin from 101 For example enter user ID 101 and then press To register a user with the authentication of ID card fingerprint the user shall first set the device to the mode ID FP See Clause 4 2 authenticating logic Logic for detail After setting to the mode ID FP 9 User Manual of FPR 207 Fingerprint Reader use ID card in the interface of entering ID number for registered user At this moment the ID card number is the ID of the current fingerprint user Press Select 1 Normal Press to register Normal finger According to above operating procedures put the desired finger evenly on the fingerprint scanner The scanner indicator flickers for 2 times Two short sounds dip dip and one long sound dip indicate the fingerprint is registered successfully and then the system returns to user registration interface automatically To register more than one fingerprints for one user ID a user shall press again to continue registration Put the desired finger on fingerprint scanner for data collection The method of registration is same to registration for the first finger The user shall repeat this operation for registration of several fingerprints under a same ID P
4. the user ID for alarm purpose the alarm ID is user defined an ID cannot be used as regular user ID when it is selected as an alarm ID Press to confirm The administrator IDs is 1 5 Users with ID number of 1 5 will be deemed as administrators by the system in default when any administrator is registered it is required to hold key for 3s and the administrator must use the fingerprint to enter the menu For example set the alarm ID of a scanner to 110 and press to confirm In standby status of the scanner the user presses the registered alarm fingerprint see aforesaid Clause 3 1 on user registration for the procedure of registering an alarm finger The scanner outputs the ID 110 to door access controller which then sends the signal to management software The management software has defined the ID 110 as the alarm user The management personnel of the surveillance software at this moment could deal with the alarm event immediately Case of alarm finger application When fingerprint scanner is in use in some important circumstances vault financial room warehouse etc and a user is threatened by someone to put the finger on the scanner to open a door the user could use the registered alarm finger Then the door will open normally and the scanner outputs automatically preset alarm ID 110 to the management software The management personnel is notified on threatening of door unlocking and then take immed
5. 0 User Manual of FPR 207 Fingerprint Reader FP xxxxxxxxxx browse fingerprint users press 9 0 to turn pages If FP xxxxxxxxxx is displayed S indicates the beginning figure and E indicates the ending figure 3 4 Clear user Clear Select 4 Clear Press key and the screen hints as follows Press to clear all the users Press to return without clearing IV System configuration Select 4 Config in main menu Press and six options are shown 1 Number device number 2 Logic authenticating logic 3 WG FMT Wiegand format 4 Temper sensor delay or 4 BUZ IN buzzer input 5 ALM ID alarm ID 6 CP MOD fingerprint collection mode 4 1 Setting of device number Number Select 1 Number Press key and the screen hints as follows Press to change the door reader device number The scope is 001 255 Type the device number and press to confirm User must set different device numbers and the default is 001 when door reader devices are in networking by RS485 4 2 Setting of authenticating logic Logic Select 2 Logic Press key and the screen hints as follows Select 1 ID FP Press to confirm The door reader device may operate under ID card mode or fingerprint mode Select 2 ID FP Press to confirm The door reader device may only operate under ID card fingerprint mode Use ID card under ID card fingerprint mode first Then scan the finger corresponding to the ID card to unlock the door
6. FPR 207 Fingerprint Reader User Manual Technological innovation originating from your desire Contents Chapter Product Introduction sesse ese cee cee ees ee eee EE cee ER EER EE ER EER AE AE cee Ill User authentication and signal characteristics reserve see X Notice on use of fingerprint registration ere eee Eer testes eee Ee Short list of menu options ET Ee IG Description of menu options oe cee cee ee cer Oe cen cee cee cee cee ee cee ree cee eee cee ee cee OE cen nee cee its Pay sh seg EER EA EE EE Il Standby image tree se ees ee EER EE see EE EE ER GE ane EER cee EER EER Re ER GE neces cee EER cee cee ee Ill Fingerprint user management Coe cee cc cece TT IT ces cne cee nee cee ces ces 3 1 Register user amp administrators Enroll tt tees se ee see see EE Gee ee EE Gee Ke eae EER Gee see ees 3 2 Delete user amp administrators Delete seers tere s EER Ee ER EE ER EE EE EER SEE ER EE Ke EE ee es 3 3 Browse user Browse ers ee EE ER EE ER EER ER EER ER GEE ER scenes EER ER cee ER Ee EER see es 3 4 Clear user Clear ee ees soe see ccc ee cee EE cee ces coe cee cee eee eee eee ees eee ees cee OER eee cee cee cesses cee IV Card management oe cee cee ee ccc OE cee cee cee cee ree cee cee ee wee cee wee ree wee ree ee wee ee cee cee ese 4 1 Register card user tese ees see ee EE Ge Ke EER EE Gee Ee EER GER GEE Re EER Gee Ke ER Gee Ke ane ee see see 4 2 Delete ID card precaution te tese Ee EER E
7. R 207 Fingerprint Reader 8 3 Screw mounting drawing a ia Pa 8 1 Hanging plate 8 2 Installation 8 4 Lower sealing plate er Installation of silica gel strip IX Assembling diagram FPR 207 fingerprint scanner is compatible to all kinds of door access controllers made in China abroad The interfaces with controller include WG26 and WG34 WG26 or WG34 is optional on the scanner 485 interface communication is supported for online operation of multiple fingerprint scanners The addition of user deletion copying of user data etc for different scanners are supported by the management tools The installation diagram for networking of the devices is shown as follows F17 F17 Fingerprint Fingerprint Reader Reader gt 5 Remote 5 RS 485 Controller c Communication Module Oo ii Door Access Controller Door Access Controller Communication l Electronic Module Electronic Control Control Lock Lock Exit Button Exit Button Figure 9 1 Online communication diagram of FPR 207 fingerprint reader 6 User Manual of FPR 207 Fingerprint Reader X Notice on use of fingerprint registration 1 To register a fingerprint put a finger on the center of the prism do no move freely to any direction 2 Put a finger on the device with force just like pressing a door bell 3 Moist the finger properly If the weather is dry the user may breathe on the finger or wipe the finger on his forehead 4 Excessiv
8. Wiegand output as follows 2 Inductive card authentication Use the card in the keyboard zone under standby status and the card s Wiegand number will be output 3 ID card fingerprint authentication Use the card and then fingerprint when the authentication logic is set to ID fingerprint When Card fingerprint function is in use set the scanner first to the mode of Card fingerprint Use the card when typing FPID during registration The card number inputted is the FPID 4 The format of Wiegand includes 26 digit and 34 digit The inductive card authentication outputs directly the Wiegand card number of the current ID card of which the format is fully compatible to that of other Wiegand inductive card readers This facilitates mixed use or upgrade of traditional and new door access systems IV Functions Professional use US dual core Blackfin and SM amp MTA door access fingerprint identification technology scratch resistant static resistant diamond crystal high resolution fingerprint scanner Extra large capacity Registration of 5 administrators 3 500 users 3 500 fingerprints Each user may register more than one fingerprint The number of fingerprints for each user is controlled by administrator ID card direct output ID card signal is directly converted to Wiegand signal for output when inductive card is used It is fully compatible to the door access system High level of security Grade 9 for fingerprint identif
9. al of FPR 207 Fingerprint Reader 5 ALM ID alarm ID ID xxxxxxxxxx press confirm to change 6 CP MOD fingerprint collection mode 1 Normal normal 2 Auto automatic collection Description of menu options I Start Connect DC12V 2V 2A power supply that meets safety requirements to the power line of the device The startup mode is entered II Standby image The standby status is entered after 1 second when the power supply is connected III Fingerprint user management Hold key for 3s to enter menu management the administrator must use fingerprint if any administrator is registered The main function menu consists of four options 1 Finger fingerprint user management 2 Config system configuration 3 1 Register user Finger Notice ID number of 1 5 will be deemed as administrators by the system in default Enter the subdirectory of the menu Select 1 Finger Press key to enter fingerprint user management which contains 1 Enroll register user 2 Delete delete user 3 Browse browse user 4 Clear clear user Select 1 Enroll Press key to enter the menu of user administrator fingerprint registration Enter user ID The administrator IDs is 1 5 Users with ID number of 1 5 will be deemed as administrators by the system in default when any administrator is registered it is required to hold key for 3s and the administrator must use the fingerprint to enter the menu Note
10. e ER EER GEE RR EE Ge RR EE Gee Ke EE Gee Ke ees ee see A5 Browse ID card eie eiee E reisi eo era EL ES KEE CEEE a aE aate nen da iaei E 4 4 1 Tamper frequency of anti tamper ts ses EE ee ee EE EE EE RE Re RR Ee ees 4 4 2 Buzzer input setting BUZ IN tees EE EE ee GEE EE ER EER ER Ge Ge Ke ee Ee 4 5 Alarm ID setting ALM ID oe see coe coe ee coe cee vee coe coe coe coe cee coe coe cee one cee vee cee cee vee 4 6 Setting of fingerprint collection mode CP MOD crrcerccrsse see see cesses cee coe cee eve V Frequently used interface sterre ree se EE FEE cee EER EE EE RE EER GER GEE see EER ee cee EER es ees N oan amp k BR OO N User Manual of FPR 207 Fingerprint Reader Foreword Respected user Thank you for choosing our product Before installing and using the product please read this manual and the enclosed CD ROM carefully and understand the basic construction performance function and basic knowledge about its installation use maintenance and system management For inguiry service and technical support please contact the dealer for guick response Statement and notice Nobody shall disassemble or copy the design of the device including parts and components circuit function and construction without prior written authorization of our company Do not install and use the product in any area with inflammable or explosive substances and any sensitive areas that may cause danger to electronic electrical devices Pl
11. e water on finger or sweating may conceal lines on fingerprint failing the scanning Please wipe the finger to dry properly 5 Severe desquamation of finger may affect use of the system Please change a finger without desquamation and then register again 6 It may be difficult for a user with a finger to register of which the fingerprint is too closely distributed that almost no fingerprint could be identified In this circumstance user may register a few fingerprints with relatively larger fingers with force 7 The fingerprint cannot be read accurately if there is any dirt or other foreign matters on the prism surface of the fingerprint scanner Clean the prism surface of fingerprint scanner regularly so as to keep the system operating under optimum status 8 In particular fingerprint scanning may fail if the finger is dirty seriously Therefore please keep the finger clean as possible during registration and use of the system The correct method of registering a fingerprint is shown in following Figure 10 1 10 1 Correct posture to press a fingerprint The incorrect method of registering a fingerprint is shown in following Figures 10 2 10 5 A dad a RE i v a mi va i t 10 2 Finger not placed evenly 10 3 Horizontal direction departing from the center mn ooo LL E o j 10 4 Finger too oblique 10 5 Vertical direction departing from the center 7s User Manual of FPR 207 Fingerprint Reader
12. ease determine a correct location for installation and install the power controller higher than DC12V 2A and prepare for connecting wires for the lock Do not use the device in any places with luminous intensity over 2000 Lux direct sunshine exposure rain vibration and oscillation with acidic gas or gas corrosive to metals with the temperature lower than 10 C or higher than 55 C with the humidity less than 20 or over 90 etc The application system does not contain any software and copyrights of Microsoft and other software and copyrights that require authorization or licensed use User shall understand and acknowledge user may be required to purchase or supplement the expenses of the copyright licensing or use of the software when applying the product with system software about which no copyright has been granted or which is not yet authorized to use by the copyright owner The product provider is not responsible for any losses because of improper use of the product including software and peripheral accessories Regular control and maintenance by designated personnel will further bring into play the reliability and superiority of our product The user manual may be supplied with some mistakes in editing typesetting and printing The company reserves the right to change any contents and parameters of this manual without further notice because of changes in construction and technological upgrade Please contact your dealer for any furt
13. f relevant parameters editing of user information in the software 3 V Performance indicators User Manual of FPR 207 Fingerprint Reader Item Technical parameters Fingerprint ID technology US BlackfinTM Dual core and SM amp MTA technology optical design high scratch resistance static resistance FRR lt 0 01 FAR lt 0 0001 Registered number of fingerprint 3 500 fingerprints 1 ID supports more than one fingerprint the unit may also be expanded to 6 000 16 000 fingerprints upon customer request Max capacity of registration 3 500 fingerprints direct inductive card operationWiegand output based on door access Control system configuration Mode of analysis 1 N 1 1 Speed lt 1 second Type of inductive card EM card or compatible ID card Reading distance 25cm Reading speed lt 0 5s Output Direct output after use of inductive card output after fingerprint authentication output of inductive card fingerprint Output format Wiegand 26 34 Alarm function Tamper alarm low level output Confinement against wrong input Optional number of tryouts of 0 255 times 180s confinement status after tryouts Communication RS 485 supporting 255 frames online maximum Display 640 matrix 2x8 dots character matrix LCD display Ambient temperature 10 C 55 C Ambient humidity 20 80 RH External power su
14. her information as well as selection of menu options Press key to cancel the operation or return Press key to confirm operation 0 and 9 keys also function to turn up and down pages in menu operation 3 Fingerprint scanner Collection and comparison for user fingerprints The lit red indicator of fingerprint scanner indicates it is waiting for the user to put the finger on it The red indicator of the scanner is constantly lit under automatic collection mode refer to the collection mode setting in the management menu 4 Buzzer Key hinting and operating status and result hinting One short sound indicates successful key operation or authentication one long sound indicates successful operation three sounds indicate authentication or Dee User Manual of FPR 207 Fingerprint Reader operation failure Two sounds indicate successful previous operation and the start of second stage operation This hints the user to press the finger again during the process of fingerprint registration II User authentication and signal characteristics The user authentication consists of three types fingerprint authentication inductive card authentication and conductive card fingerprint indication 1 Fingerprint authentication Under automatic collection mode put a finger on the fingerprint scanner so as to start the 1 N type of authentication Wiegand signal consisting of the user ID will be outputted upon fingerprint authentication see the format of
15. her inquiries Statement about human rights and privacy 1 The civil purpose fingerprint identification device only collects and saves feature points numerical value of fingerprint other than fingerprint image so this does not relate to reservation of privacy The fingerprint image shown by the software is collected on site and only for the purpose of observing fingerprint quality 2 As an equipment provider we are not responsible for any consequence as a result of use our equipment directly or indirectly 3 If you should have any disputes about our equipment s relationship with human rights or privacy or any other issues please contact your employer or provider directly User Manual of FPR 207 Fingerprint Reader Chapter I Product Introduction I Brief introduction Nowadays in light of high technology intelligent information processing has become a most effective way for improving efficiency standardizing administration and carrying out accurate identification especially in the field of enterprise and public undertaking management Door access control system entry and exit control and management system is now an important component of security protection system In developed nations door access system is making progress rapidly with a growth rate much higher than that of other security protection products The fundamental reason for fingerprint door access system to overcome other door access systems is that it changes the pas
16. iate measures Note Please understand the minimum ID number of the door access controller connected when setting up user ID If the minimum allowable user ID is 100 for a certain door access controller the user ID registered at the scanner shall begin from 101 4 6 Setting of fingerprint collection mode CP MOD Select 6 CP MOD Press and the screen hints as follows Two modes are available 1 Normal normal mode 2 Auto automatic mode 12 User Manual of FPR 207 Fingerprint Reader Under normal mode the reader s indicator light is off for standby status To analyze fingerprint press key and the indicator is lit Put a finger on the fingerprint scanner for analysis Under auto mode the reader s indicator light is lit for standby status To analyze fingerprint put a finger directly on the scanner for analysis it is recommended the device is used under auto mode for convenience of use V Frequently used interface Standby interface Administrator Tamper alarm Identification ready authentication Card comparison passed Sensor closed Identification failure Verification failure Invalid card ID card fingerprint ID card fingerprint 180s anti tamper authentication authentication confinement 43
17. ication security FRR lt 0 0001 false rate Identification speed High speed of identification fingerprint identification S 1s inductive card identification S 0 5s Authentication Three modes of authentication include fingerprint inductive card and inductive card fingerprint facilitating system upgrade of existing and new door access control Output format Standard Wiegand26 or Wiegand34 output format compatible to door access controllers made in China and abroad similarity of the mode of connection by the scanner to ordinary inductive card reader with full compatibility and easy installation Human machine interface Human machine interface with voice function and character LCD display visual and convenient Tamper alarm Tamper alarm function on site alarm and level output provision of external alarm or connection to 110 network Duress alarm Designated alarm ID could be outputted in case of fingerprint unlocking during duress alarm Confinement against wrong input Options for 0 255 times against tryout 180s confinement status after tryouts Off line operation Mode of fingerprint identification access for administrator based on disconnection to PC supporting direct registration modification deletion setting etc on the local frame Network communication 485 online communication reading and writing with dedicated software in the attached CD ROM for fingerprint scanner backup copying of fingerprint information setting o
18. ignal positive White 9 GND numerical same to power supply grounding Black 10 NC reserved normally close contact switch of alarm output relay Blue 11 NO reserved normally open contact switch of alarm output relay Gray 12 COM reserved common contact switch of alarm output relay Orange JP2 OFF close field alarm NO open field alarm Toggle switch KEY Temper switch loosen for alarm press to cancel Pressure switch VIII Installation procedures 1 Locate 4 mounting holes with mounting hanging plate at a proper height about 130cm above ground and then dismount the hanging plate Drill the holes with O6 chopping bit and then mount the plastic expansion screws attached in the accessories until the screw heads are even with the wall surface Connect all necessary wires and then mount the mounting hanging plate Finally fasten with drywall screws 2 Insert the connecting plug to the mainframe socket Connect to power supply to test the various functions Then press the mainframe on the mounting hanging plate downward and fasten with attached 3x6 flat head screw Finally cover with the attached lower sealing cover plate and insert silica gel joint strip Mounting plate width 6 1CM Actual device width 6 7CM TT Screw hole distance 4 6 cm Screw hole distance 8 9 cm Mounting plate height 13 7cm Actual device height 14 3cm Installation dimensions of FPR 207 door reader 5 User Manual of FP
19. pply power DC10 15V lt 3 W Volume weight 143mmx67mmx50mm 255g VI Packaging list No Equipment Unit Quantity 1 Fingerprint reader Set 1 2 CD ROM of application management software Piece 1 3 Dedicated connecting wire Packaget 1 4 Instruction manual electronic form in the CD ROM Piece 1 5 Silica gel fillet Piece 1 6 Drywall screw Plastic expansion screw Pair 4 7 Flat head screw Piece 3 8 Connecting accessories Piece Several 9 Bottom mounting cover plate Piece 1 10 Certificate of conformity and quality assurance Copy 1 Please check completion of above accessories If there exists any discrepancy please contact your distributor immediately User Manual of FPR 207 Fingerprint Reader VII Interfaces The hardware interfaces including power input RS485 communication port relay port etc The feet are defined in the following table on the rear side of the fingerprint reader from left to right Socket foot position Item Color position 1 12V DC10 12V input Red 2 GND power supply grounding Black 3 BUZ_IN buzzer signal input low level buzzer sound Green i WG INT Wiegand delay output low level indicating that Wiegand White signal is being outputted 5 WG DO Wiegand signal DO Brown 6 WG DI1 Wiegand signal D1 Yellow 7 485B 485 communication signal negative Purple 8 485A 485 communication s
20. ress and then change a finger for registration The number of fingerprints to register under a same ID is not limited and the user has the free choice for registration To delete a user with several fingerprints registered it is required to delete the ID only and then all the fingerprints data under this ID will be deleted Note 1 Normal means Normal finger To register a fingerprint for normal unlocking user needs only to select 1 Normal for registration 2 Alarm means Alarm finger duress alarm fingerprint When an alarm fingerprint is registered user may press the alarm finger in an emergency condition and the scanner unlocks the door normally and a group of present alarm ID numbers is transmitted to door access controller The signal is also transmitted to the management software for alarming and hinting the management personnel Please refer to the following item 4 5 on alarm ID setting for the details of setting up alarm ID 3 2 Delete user Delete Notice ID number of 1 5 will be deemed as administrators by the system in default Select 2 Delete Press key and the screen hints as follows to input the user ID to delete Press to delete the user precaution Press to return 3 3 Browse user Browse Select 3 Browse Press key and the screen hints as follows C xxxxx number of fingerprints M xxxxx capacity of fingerprints Press to browse registered user IDs shown as follows 1
21. sive protection mode of previous products that identifies article other than people preventing unauthorized personnel from entering regular channels FPR 207 fingerprint and inductive card reader is capable of outputting Wiegand 26 34 standard signal and supports online communication by RS485 It is compatible to traditional and new door access control system readers so as to upgrade the system to fingerprint and inductive card door access control system This product is characteristic of universality reliability innovative design pleasant configuration and the ease of installation The product belongs to the fingerprint identification device with the widest application in the field of door access system It adopts wall hanging installation and features the ease of operation innovative structural design and pleasing exterior design The product is suitable for modern application environment To upgrade the system to the all purpose door access control system will add to the satisfactory building environment II Construction LCD display Functional Inductive area keys of ID card Fingerprint scanner The human device interface consists of display keys fingerprint scanner and beeper Their functions are described as follows 1 Display Indicating user s authentication status and result management menu etc 2 Keys 12 keys altogether including numerical keys 0 9 key and key Numerical keys are used for typing ID and ot

Download Pdf Manuals

image

Related Search

Related Contents

Extra Receiver for Guardian® Underground Fence®  Cables Direct Display Port - VGA m/f  Visiolite ® Visiolite ®  Document  Emerson SDU DIN Rail AC UPS Specifications  Moen T9321BN User's Manual  Split Type Air Conditioner ENGINEERING DATA  Sony KDL-46EX711 46" Full HD Black  1. 化学物質等および会社情報 2. 危険有害性の要約  