Cycle sensor quick start

image

Contents

1. WET Labs Cycle sensor quick start Set up sensor Refer to user manual section 2 1 for details Caution The waste solution from the cartridges is Hazardous Waste Follow the applicable regulations to discard the solution Wear Personal Protective Equipment PPE to work with cartridges Remove the sensor and the spare parts kit from the plastic case Remove the three cartridges from the fiberboard box Put the sensor on its side and remove the seven Phillips screws that attach the protective sleeve to the sensor Slide the protective sleeve off the sensor Keep the screws and the sleeve Push on the stainless steel tab of the fluid couplet to make sure that it s unlocked Set the blue cartridge on the guide pins at location S and push down until it clicks into place Install the yellow cartridge and then the red cartridge The cartridges are correctly installed if they can t be pulled off of their bases unless the stainless steel tab is pushed Install software Refer to user manual section 2 2 for details l 2 3 4 eee 7 8 9 Make sure that the host PC has the latest Java version installed Install the host software from the CD that comes with the sensor Extract the whole zip file and double click on exe Use the cable from the spare parts kit to connect the sensor to the host PC serial port and a 12 V power supply Start the host software Select the host PC COM port t
2. ane section 3 3 PUREE er Rare gi emo 03 15 16 17 18 19 20 03 15 16 17 18 19 2 2 17 Attach the sensor to its deployment mounting un naan zn n in mx x 7 x 18 Connect the sensor to the deployment cable peli 19 Make sure the outlet tubing flows has no blockages or kinks aa ee 20 Attach a safety rope to one of the eye bolts sions Sample terval 1 0 0 21 Make sure the supplied power is sufficient for deployment section 3 2 Te 22 Take the red reagent cartridge back to the laboratory to flush and send back to the manufacturer section 6 8 Prime Start Time 09 30 Sample Start Time 10 00 Cycle Field Service Checklist Revision B 20 Jan 2014
3. hat the Cycle is connected to Use the PC s Device Manager or the USB serial adapter s software to determine the COM port Supply power to the sensor Go to the Tools menu of the host software and select the Deployment Wizard Ctrl D Select Autonomous or Synchronous file mode SDI 12 then push Next Select the priming start date and time and the sampling start date and time Set the sample interval Put a value in the Number of Samples area Do not leave it blank Make sure the Skip Prime Cycle checkbox is not selected Set the Cal Frequency value A value of less than 2 can reduce the number of samples per set of cartridges to less than 1000 Push Send Settings to Cycle then OK to make a settings report Save the report 10 Push Finish then Yes to make a results report then push Yes to add it to the previous report Prepare sensor for deployment Refer to user manual section 2 7 for details 5 Deploy the sensor refer to user manual section 3 3 for details Caution The contents of the syringe after pulling a vacuum are considered Hazardous Waste Dispose of properly Prime the sensor with a vacuum attach the supplied syringe with a 1 16 barb to the outlet tube of R1 Pull the plunger to 10 mL At the Settings tab set the pump to operate for 100 cycles Do this step again for the R2 and Cal cartridges Make sure the reagent tubing that connects the cartridges and the inlet barbs does not have any air bubbles Fill the su
4. he host PC and power supply section 2 1 5 Use a2 cleaning solution of Micro 90 to clean the sensor section 6 1 Pull the tubing straight off the hose barb Unwrap the exhaust tubing from the top of the sensor and put one end into a beaker Connect a syringe to a 25 cm length of 1 8 ID Tygon tubing Use the syringe to fill the tubing Connect the other end of the tubing to the S barb Disconnect the syringe and put the old tubing it was connected to into the bottle of cleaning solution Go to the Settings tab of the host software and push Flush Let the solution soak in the sensor for 2 to 1 hour moaocge eo 6 Change the reagent cartridges section 6 2 7 Change the filters and screens section 6 3 ae 8 Clean sensor of macro fouling section 6 4 a 9 Flush the Micro 90 from the sensor section 6 5 Broken pin 10 Use the vacuum prime procedure to reduce bubbles from cartridge ar installation section 6 6 11 Clean and lubricate the bulkhead connectors section 6 7 13 Fill the filters with DI water section 2 7 14 Wrap the tubing around the eye hooks 15 Install the protective sleeve again section 6 5 15 Use the host software deployment wizard to set up the sensor for Cycle Deployment Wizard deployment section 2 7 Priming Start Date and Time Sampling Start Date and Time 16 Make sure that the sensor is in sleep mode then disconnect the host cable Eas oe
5. pplied syringe with DI water and attach it to the 1 8 Tygon tubing from the sample hose barb Push water to drip out of the bottom of the filters Pinch the tubing and carefully connect it to the sample inlet barb again Try not to let air into the tubing Make sure that the tubing is wound around the eyebolts for transport Install the blue protective outer sleeve again Align the indentions on the outer sleeve with the eye bolts and screw holes Make sure that the sensor is in sleep mode then disconnect the host cable Put the sensor in a bucket in approximately 20 cm of water Take the sensor to the deployment site Status Sleeping 6 Connect the sensor to the power source then submerge the sensor in the bucket at the mooring Cycle Quick Start Guide Revision B 20 Jan 2014 WETO Labs Cycle sensor field service checklist Caution The waste solution from the cartridges is Hazardous Waste Follow the applicable regulations to discard the solution Wear Personal Protective Equipment PPE to work with cartridges Refer to the sections below in the user manual for details about these steps 1 Make sure the sensor is not on Select Stop or Stop Now if the sensor is in low power sleep mode or Stop and Flush if the sensor is in operation 2 Remove the sensor from its deployment be careful to keep air out of the sensor section 3 4 3 Remove the protective sleeve section 5 4 Connect the sensor to t

Download Pdf Manuals

image

Related Search

Related Contents

MANUAL DE INSTRUCCIONES CAVA CLIMATIZADA  CDA TC57CH faucet  Télécharger - Ville de Grand Quevilly  AS - 200 - AVOLITES  MANUAL DE INSTRUCCIONES  Speaker Installation  V2 Installation & User Guide A5.pages  ADSS Server Release Notes  View/Open - ESIRC - Emporia State University  LevelOne Wireless P/T Network Camera  