1. 18 Options Guide RX200 S3 Preparation Opening the server 4 2 Opening the server Figure 4 Removing the top cover gt For removing the top cover press the cover button downward 1 gt Slide the cover approx 1 cm towards the rear of the server and lift it off 2 RX200 S3 Options Guide 19 5 Main Memory A CAUTION Please observe the safety information in the chapter Safety Instructions on page 11ff The system board supports up to 32 Gbytes of main memory 8 slots 2 slots form a memory bank are provided for the main memory Each memory bank is equipped with two 512 Mbyte 1 Gbyte 2 Gbyte or 4 Gbyte FBD533 PC2 4200F or FBD667 PC2 5300F Fully Buffered DIMM memory modules ECC with memory scrubbing and with the Single Device Data Correction SDDC Chipkill function is standard 5 1 Population rules Figure 5 Structure of the main memory in memory banks and memory modules The memory modules have to be based on x4 or x8 organised FBD533 PC2 4200F or FBD667 PC2 5300F fully buffered DIMM modules and must be populated in pairs You must only use memory modules released by Fujitsu Siemens Computers Each pair must consist of identical memory modules 2 way interleaved mode RX200 S3 Options Guide 21 Population rules Main Memory The module capacity between pairs can differ e g pair 1A 1B can be populated with two 512 Mbyte modules and pair 2A 2B with two 1 Gbyte modules The tabl
2. gt Close the server plug in the power plugs and switch on the server as described in the chapter Completion on page 41 28 Options Guide RX200 S3 Processors Exchanging the processor 6 2 Exchanging the processor CAUTION You may only use processors of the same type on the system board gt Open the server as described in the chapter Preparation on page 17f gt Lift the air duct up and off Hl LL UN LU NN 1 HAA III UN gt Remove the four screws of the heat sink in diagonally opposite sequence see figure gt Turn the heat sink carefully back and forth to loosen it Then lift it out to remove it gt Remove the residual thermal paste from the underside of the heat sink gt Clean the underside of the heat sink using a lint free cloth RX200 S3 Options Guide 29 Exchanging the processor Processors Figure 14 Removing the old processor gt Release the socket lifter by pressing it sideways and pull it upward as far as it will go 1 Open the cover 2 Lift the installed processor carefully out of the socket 3 Figure 15 Installing the new processor gt 30 Position the new processor over the socket and then carefully press it into the socket 1 T CAUTION The processor can only be installed in one particular direction Note the marking on one of the corners To avoid damaging t
3. 4 2 Opening the server 19 5 Main Memory ra 21 5 1 Population rUlES aerea AAA 21 5 2 Upgrading replacing main memory 23 6 PIOCGSSOIS 6 444 6 2 rra 25 6 1 Installing a second processor 29 6 2 Exchanging the processor 29 6 3 Exchanging the heatsink 32 7 CD DVD DIVE 2 lt 4 ss ass css Ness eed eee ea 33 8 Controllers in Non Hot Plug PCI Slots 37 8 1 Installing controllers 39 9 Completion sis 4458 42 JE be we eee ae ee 41 9 1 Closing the Server 41 9 2 Installing the server in the rack 42 Abbreviations 20205024520 a ade 43 Related publications 49 CK ke Aa AEREA Re Be HO 51 RX200 S3 Options Guide 1 Preface The PRIMERGY RX200 S3 server is an Intel based server for mid size networks and large companies The server is suitable for use as a file server and also as an application information or Internet server 1 1 Overview of the documentation PRIMERGY manuals are available in PDF format on the ServerBooks CD which is supplied as part of the ServerView Suite package for every server system These PDF files can also be downloaded free of charge from the Internet At http manuals fujitsu siemens com you will find an overview page showing the online documentation available on the Internet You can go to the PRIMERGY Server docum
4. Time Clock RTDS Remote Test and Diagnosis System SAF TE SCSI Accessed Fault Tolerance Enclosures SAS Serial Attached SCSI SATA Serial ATA SBE Single Bit Error SCA Single Connector Attachment SCSI Small Computer System Interface SDR Sensor Data Record SDRAM Synchronous Dynamic Random Access Memory SEL System Event Log SMI System Management Interrupt SSU System Setup Utility SVGA Super Video Graphics Adapter USB RX200 S3 Options Guide 47 Abbreviations Universal Serial Bus VGA Video Graphics Adapter ZCR Zero Channel RAID 48 OptionsGuide RX200 S3 Related publications PRIMERGY manuals are available as PDF file on the ServerBooks CD The ServerBooks CD is part of the ServerStart Bundle delivered with each server system The actual version of the necessary manuals can be downloaded free of charge from the Internet The overview page showing the online documentation avail able in the Internet can be found via the URL http manuals fujitsu siemens com choose industry standard servers 1 Safety notes and other important information 2 Ergonomics 3 Warranty 4 System Board D2300 Technical Manual 5 BlOS Setup Reference Manual 6 PRIMERGY RX200 S3 Operating Manual 7 Quick Start Hardware PRIMERGY RX200 S3 Leaflet 8 Quick Start Software PRIMERGY ServerView Suite Leaflet 9 PRIMERGY ServerView Suite ServerStart User Manual 10 Global Arra
5. foreign bodies switch off the device immedi ately remove the power connector from the grounded power outlet and contact your customer service centre Proper operation of the device in accordance with IEC 60950 DIN EN 60950 is only ensured if the casing is completely assembled and the rear covers for the installation openings have been put in place electric shock cooling fire protection interference suppression Install only system extensions that satisfy the requirements and rules governing safety electromagnetic compatibility and telecommunica tions terminal equipment If you install other extensions you may damage the system or violate these safety regulations Information on which system extensions are suitable can be obtained from the customer service centre or your sales outlet The components marked with a warning label e g lightning symbol may only be opened removed or exchanged by authorized qualified personnel The warranty is invalidated if the device is damaged during the instal lation or replacement of system extensions You may set only those resolutions and refresh rates specified in the operating manual for your monitor Otherwise you may damage the monitor If you are in any doubt contact your sales outlet or customer service centre Options Guide 13 Safety Instructions Batteries CAUTION e Incorrect replacement of batteries may lead to risk of explosion The batteries may only be
6. that should be emphasized text which follows this symbol describes activities that must be performed in the order shown CAUTION pay particular attention to text marked with this symbol Failure to observe this warning may endanger your life damage the server or lead to loss of data supplementary information remarks and tips follow this symbol Table 1 Notational conventions 8 Options Guide RX200 S3 2 Procedure CAUTION e The actions described in this manual should only be performed by engineers service personnel or technical specialists e Equipment repairs should only be performed by authorized qualified staff e Any failure to observe the guidelines in this manual and any unautho rized openings and improper repairs could expose the user to risks e g electric shock fire hazards and could also damage the equipment e Please note that any unauthorized opening of the device will result in the invalidation of the warranty and exclusion from all liability First of all please familiarize yourself with the safety instructions in the chapter Safety Instructions on page 11ff Make sure that all required manuals see Additional documentation about the server on page 5 are available printing out the PDF files if necessary You will definitely need the Operating Manual for the server and the Service Supplement for the server the Technical Manual for the system board S
7. 00 S3 Safety Instructions To protect the CD ROM DVD drive and prevent mechanical damage as well as premature wearing of the CDs you should observe the following advice Only insert the CDs in the drive when needed and remove them after use Store the CDs in suitable sleeves Protect the CDs from exposure to heat and direct sunlight Note on the laser The CD ROM DVD drive contains a light emitting diode LED classified according to IEC 825 1 1993 LASER CLASS 1 Modules with electrostatic sensitive devices Electrostatic sensitive components are identified by the following sticker Figure 1 ESD label CAUTION When you handle components fitted with ESDs you must observe the following points under all circumstances e Remove the power plug from the power socket before inserting or removing components containing ESDs e You must always discharge static build up e g by touching a grounded object before working with such components e The equipment and tools you use must be free of static charge e Use a grounding cable designed for this purpose to connect yourself to the system unit as you install components RX200 S3 Options Guide 15 Safety Instructions CAUTION e Always hold components with ESDs at the points marked green touch points e Do not touch any exposed pins or conductors on a component e Place all components on a static free base relevant European or international s
8. 14 onthe laser 15 P PCI board upgrade 39 processor exchange 29 installation 25 26 module 26 upgrade 7 R removal riser card holder 39 server from rack 18 top cover 19 riser card holder installation 40 removal 39 T target group 5 U upgrade CD ROM DVD drive 33 Options Guide 51 Index controller 39 main memory 23 PCI board 39 V ventilation duct installation 28 52 Options Guide RX200 S3 A a ina Fujitsu Siemens Computers GmbH User Documentation 33094 Paderborn Germany Fax 0 700 372 00001 email manuals Ofujitsu siemens com http manuals fujitsu siemens com Submitted by Comments on PRIMERGY RX200 S3 Server System RX200 S3 Comments Suggestions Corrections A a ina Fujitsu Siemens Computers GmbH User Documentation 33094 Paderborn Germany Fax 0 700 372 00001 email manuals Ofujitsu siemens com http manuals fujitsu siemens com Submitted by Comments on PRIMERGY RX200 S3 Server System RX200 S3 Comments Suggestions Corrections ee FUJITSU Information on this document On April 1 2009 Fujitsu became the sole owner of Fujitsu Siemens Compu ters This new subsidiary of Fujitsu has been renamed Fujitsu Technology So lutions This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed Please note that all company references and copyrights in this document have been
9. 24 Installing the cover gt Position the top cover so that it projects approx 1 cm to the rear gt Push the top cover completely forward The housing button will engage automatically RX200 S3 Options Guide 41 Installing the server in the rack Completion 9 2 Installing the server in the rack E 4 a f ac Figure 25 Installing the server in the rack CAUTION At least two people are needed to position the server in the rack gt Push the prepared server into the rails that are attached to the rack until the server rails engage il Ensure that the server is inserted horizontally and is not tilted Press the safety springs in on both sides 2 Gently push the server as far as it will go into the rack 3 Fasten the server to the rack 4 using the two knurled screws front panel vv v NY Plug in all plugs and switch the server on 42 OptionsGuide RX200 S3 Abbreviations AC Alternating Current ANSI American National Standards Institute ASR amp R Automatic Server Reconfiguration and Restart ATA Advanced Technology Attachments BIOS Basic Input Output System BMC Baseboard Management Controller CC Cache Coherency CD Compact Disk CD ROM Compact Disk Read Only Memory CHS Cylinder Head Sector CMOS Complementary Metal Oxide Semiconductor COM Communication CPU Central Processing Unit DC RX200 S3 Options Guide 43 Abbreviations Direct Current DIMM Dual In
10. PRIMERGY RX200 S3 Server Options Guide Edition August 2006 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual Your feedback helps us optimize our documentation to suit your individual needs Fax forms for sending us your comments are included in the back of the manual There you will also find the addresses of the relevant User Documentation Department Certified documentation according to DIN EN ISO 9001 2000 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft fur Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2006 Fujitsu Siemens Computers GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers Contents 1 PR 6 ok we es es Ra di SRG ERS cou 5 1 1 Overview of the documentation 5 1 2 Extensions and conversions 7 13 Notational conventions 8 2 POCOS rar narra ARA an 9 3 Safety Instructions 11 4 Prepad ss ss OHO HESS SES OOK ee vs 17 4 1 Pulling out removing the server 17
11. ains outlet is freely accessible The power switch does not disconnect the device from the mains voltage To completely disconnect it from the mains voltage you must remove the power plug from the power outlet Always connect the device and the attached peripherals to the same power circuit Otherwise you run the risk of losing data if for example a power outage occurs and the central processing unit is still running but the peripheral device e g a storage subsystem has failed Data cables must be adequately shielded to avoid interference For the LAN wiring the requirements according to standards EN 50173 and EN 50174 1 2 apply The minimum requirement is the use of a protected LAN line of category 5 for 10 100 Mbps Ethernet and or of category 5e for Gigabit Ethernet The requirements of the specification ISO IEC 11801 must also be taken into account Route the cables in such a way that they do not form a potential hazard tripping and that they cannot be damaged When connecting the device refer to the relevant notes in the operating manual Do not connect or disconnect any data transmission cables during a thunderstorm lightning hazard OptionsGuide RX200 S3 Safety Instructions CAUTION RX200 S3 Be careful to ensure that no objects e g jewelry paper clips etc or liquids get inside the device electric shock short circuit In emergencies e g damaged casing elements or cables penetration of liquids or
12. e below shows the order in which the memory banks must be equipped Bank 1 Bank 2 Bank 3 Bank 4 module pair module pair module pair module pair 1A 1B 1C 1D 2A 2B 2C 2D Equipped Empty Empty Empty Equipped Equipped Empty Empty Equipped Equipped Equipped Empty Equipped Equipped Equipped Equipped Memory mirroring Either 4 or 4 4 identical memory modules are required for memory mirroring Memory 3 bank Channel 1A 1C 2A 2C module Equipment 4 identical memory modules a E o 4 identical memory modules 4 identical memory modules 22 OptionsGuide RX200 S3 Main Memory Upgrading replacing main memory 5 2 Upgrading replacing main memory gt Open the server as described in the chapter Preparation on page 17f gt In order to make the slots lateral ejector tabs more readily accessible lift the air duct above the processors up and off Figure 6 Removing a memory module gt Flip the ejector tabs on each side of the slot outward 1 This levers an installed memory module out of its slot gt Ifthe slot was already occupied Remove the memory module from the slot 2 RX200 S3 Options Guide 23 Upgrading replacing main memory Main Memory Figure 7 Installing a memory module gt Carefully press the memory module into the slot 1 until the ejector tabs on both sides of it engage 2 gt Reinstall the air duct Ensure that the hooks on the air duct see figure 8 engage on the fan
13. ease note that any unauthorized opening of the device will result in the invalidation of the warranty and exclusion from all liability Before setting up CAUTION e During installation and before operating the device observe the instructions on environmental conditions for you device e Ifthe device is brought in from a cold environment condensation may form both inside and on the outside of the machine Before operating the device wait until it is absolutely dry and has reached approximately the same temperature as the installation site Failure to observe these guidelines can lead to material damage of the device e Transport the device only in its original packaging or in packaging which protects it from knocks and jolts RX200 S3 Options Guide 11 Safety Instructions Installation and operation CAUTION 12 If the rack model is integrated in an installation that receives power from an industrial public power supply network with the IEC309 connector the public power supply protection must comply with the requirements for the non industrial public power supply networks for the type A connector The server automatically adjusts to a mains voltage between 100 V and 240 V Make sure that the local mains voltage is neither above nor below this range This device has safety tested power cables and must only be connected to properly grounded power outlets Make sure that the power socket on the device or the grounded m
14. ed The Service Supplement for PRIMERGY RX200 S3 PDF available on the ServerBooks CD supplied You can order a supplementary ServerBooks CD by sending an e mail to the following address quoting your server data Reklamat PC LOG fujitsu siemens com Further sources of information Technical Manual on the relevant rack Manual on the monitor Manual on ServerView Server Management Manual on RemoteView remote server management Documentation on boards and drives Documentation on your operating system Information files on your operating system see also Related publications on page 49 6 Options Guide RX200 S3 Preface Extensions and conversions 1 2 Extensions and conversions Second processor The system board can be upgraded with a second processor Only processors of the same type may be used on the system board The second processor must have the same clock frequency as the first processor Extension of the main memory The eight slots for the main memory are suitable for FBD533 PC2 4200F or FBD667 PC2 5300F memory modules Their organization in four memory banks allows fast memory access with four way interleaving Memory modules must always be installed in pairs memory bank must always be fully equipped and with the same type of memory modules For further details see chapter Main Memory on page 21 CD DVD drive option The PRIMERGY RX200 S3 Server is equipped w
15. entation by clicking on industry standard servers Concept and target groups This Options Guide shows you how you can expand and upgrade the server Caution The activities described in this manual may only be performed by specialist personnel with technical training How to install remove the hot plug components is described in the Operating Manual for the server Additional documentation about the server The PRIMERGY RX200 S3 documentation comprises the following additional manuals The Security and other important information manual printed copy always supplied with the server and available as a PDF file on the ServerBooks CD supplied The Guarantee manual printed copy always supplied with the server and available as a PDF file on the ServerBooks CD supplied RX200 S3 Options Guide 5 Overview of the documentation Preface The Operating Manual for PRIMERGY RX200 S3 PDF available on the ServerBooks CD supplied The Technical Manual for the system board D2300 PDF available on the ServerBooks CD supplied The BIOS Setup manual PDF available on the ServerBooks CD supplied The Ergonomics manual PDF available on the ServerBooks CD supplied The ServerView Suite manual printed copy always supplied with the server and available as PDF file on the ServerBooks CD supplied The Adaptec HostRAID User s Guide PDF available on the ServerBooks CD suppli
16. er by pressing it sideways and pull it upward as far as it will go 1 gt Open the cover 2 gt Remove the plastic cover 3 26 Options Guide RX200 S3 Processors Installing a second processor Figure 11 Installing the processor gt Position the new processor over the socket and then carefully press it into the socket 1 CAUTION The processor can only be installed in one particular direction Note the marking on one of the corners To avoid damaging the pins or the processor do not force it into the socket gt Close the cover 2 gt Lock the processor in place in the socket by returning the socket lifter to its original position 3 RX200 S3 Options Guide 27 Installing a second processor Processors Installing the heat sink set t yr Aa me a M va Figure 12 Installing the heat sink gt Fit the heat sink on the processor such that the airflow arrow 1 is facing the rear side of the server gt Attach the heat sink with four screws Tighten the screws in diagonally opposite sequence 2 CAUTION Never install a processor without a heat sink The processor is likely to overheat which may cause damage to the processor and the system board Installing the air duct gt Reinstall the air duct Reattach the air duct Ensure that the hooks on the air duct see figure 8 on page 24 engage on the fan s rear panel
17. f If you want to replace components which are not hot pluggable you must proceed as follows gt Exit all applications and shut down the server correctly gt If your operating system has not switched off the sever press the on off switch gt Unplug the power plugs The system board has one PCI X and one PCle x8 slot Because of the server s installation height these can only be used via a riser card Two different types of riser card are available here e Type A Two slots for PCI X controller Slot 1 64 bit 100 MHz low profile max length 175 mm Slot 2 64 bit 133 MHz max length 175 mm Slot 1 Figure 20 Riser card type A 2 PCI X RX200 S3 Options Guide 37 Controllers in Non Hot Plug PCI Slots e Type B One slot each for a PCI X and a PCle controller Slot 1 64 bit 100 MHZ low profile max length 175 mm Slot 2 PCle x8 max length 315 mm Figure 21 Riser card type B 1 PCI X and 1 PCle x8 il Both slots are not hot pluggable 38 OptionsGuide RX200 S3 Controllers in Non Hot Plug PCI Slots Installing controllers 8 1 Installing controllers gt Open the server as described in the f Removing the riser card holder A T e AMO ie d i gt 4 Wy A En tit Lan i AAA IATA eee i j ets T TAL BEN bat Lge sado ad Het Re SS E ZZ N Figure 22 Removing the riser card holder gt Grasp the riser card at the two green points labeled with LIFT UP and pull
18. he pins or the processor do not force it into the socket Close the cover 2 Lock the processor in place in the socket by returning the socket lever to its original position 3 Options Guide RX200 S3 Processors Exchanging the processor gt Apply a small amount of thermal paste to the upper side of the new processor gt Ensure a thin and even distribution of the thermal paste gt Fit the heat sink on the processor such that the airflow arrow labeled is facing the rear side of the server see page 28 gt Fasten the heat sink by tightening the four screws in a crossover pattern gt Reinstall the air duct Ensure that the hooks on the air duct see figure 8 on page 24 engage on the fan s rear panel gt Close the server plug in the power plugs and switch on the server as described in the chapter Completion on page 41 RX200 S3 Options Guide 31 Exchanging the heat sink Processors 6 3 Exchanging the heat sink gt 32 Open the server as described in the chapter Preparation on page 17f Remove the air duct Remove the four screws of the heat sink in diagonally opposite sequence see page 29 Turn the heat sink carefully back and forth to loosen it Then lift it out to remove it Clean the surface of the processor with a lint free cloth Fit the heat sink on the processor such that airflow arrow is facing to the rear side of the server See page 28 Attach the heat sink with fou
19. hut down the server correctly switch it off pull out the power plug and open the server as described in the chapter Preparation on page 17ff gt Extend or upgrade your server as described in the relevant chapter How to install remove the hot plug components is described in the Operating Manual for the server Close the server plug all mains plugs into the power outlets and switch on the server as described in the chapter Completion on page 41ff Startthe operating system and if necessary configure it as required see the Operating Manual RX200 S3 OptionsGuide 9 3 Safety Instructions The following safety instructions can also be found in the manual entitled Safety This device complies with the relevant safety regulations for data processing equipment including electronic office machines for use in an office environment If you have any questions as to whether you can set up the device in your particular environment please contact your sales outlet or our customer service centre CAUTION e The actions described in this manual should only be performed by engineers service personnel or technical specialists e Equipment repairs should only be performed by qualified staff e Any failure to observe the guidelines in this manual and any unautho rized openings and improper repairs could expose the user to risks e g electric shock fire hazards and could also damage the equipment e Pl
20. it up and out Installing a controller Please read the documentation supplied with the controller Plug any necessary cables onto the controller gt Remove the slot cover from the riser card holder Keep the slot cover for future use If you remove the controller you il must reinstall the slot cover to comply with EMC regulations regula tions on electromagnetic compatibility and to satisfy cooling require ments and fire protection measures RX200 S3 OptionsGuide 39 Installing controllers Controllers in Non Hot Plug PCI Slots _ Slot 1 aari i J pal al Le a i m a ne Figure 23 low profile Slot 1 standard height or low profile Slot 2 gt Plug the board into the PCI slot on the riser card that is suitable for the height of the board il Make sure that the slot cover fits into the appropriate recess gt f necessary plug in the cables on the board and other components Reinstalling the riser card holder gt Position the riser card holder on the system board s PCI slots gt Using the green points labeled with PUSH push the riser card carefully into the PCI slots gt Close the server plug in the power plugs and switch on the server as described in the chapter Completion on page 41f 40 OptionsGuide RX200 S3 9 Completion CAUTION Please observe the safety information in the chapter Safety Instructions on page 11ff 9 1 Closing the server Figure
21. ith a slimline bay intended for a CD DVD drive 5 25 x 0 5 inch For further details see chapter CD DVD Drive on page 33 Additional controllers in non hot plug PCI slots The system board has one PCI X and one PCle x8 slot Because of the server s installation height these can only be used via a riser card Two different types of riser card are available here e Type A Two slots for PCI X controller Slot 1 64 bit 100 MHz low profile max length 175 mm Slot 2 64 bit 133 MHz max length 175 mm e Type B One slot each for a PCI X and a PCle controller Slot 1 64 bit 100 MHz low profile max length 175 mm Slot 2 PCle x8 max length 315 mm il Both slots are not hot pluggable For further details see chapter Controllers in Non Hot Plug PCI Slots on page 37 RX200 S3 OptionsGuide 7 Notational conventions Preface Second power supply unit option As an option the power supply can be expanded with an extra power supply unit to create a redundant power supply If a power supply unit fails the redundant configuration assures continued operation The defective power supply unit can be replaced during operation For information on installing the second power supply unit please refer to the operating manual 1 3 Notational conventions The following notational conventions are used in this manual indicate commands menu items or software programs Quotation marks indicate names of chapters and terms
22. legally transferred to Fujitsu Technology Solutions Contact and support addresses will now be offered by Fujitsu Technology So lutions and have the format ts fujitsu com The Internet pages of Fujitsu Technology Solutions are available at http ts fujitsu com and the user documentation at http manuals ts fujitsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu bergegangen Diese neue Tochtergesellschaft von Fujitsu tr gt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor l ngerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion Bitte beachten Sie dass alle Firmenbez ge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions bergegangen sind Kontakt und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form ts fujitsu com Die Internetseiten von Fujitsu Technology Solutions finden Sie unter http de ts fujitsu com und unter http manuals ts fujitsu com finden Sie die Benutzerdokumentation Copyright Fujitsu Technology Solutions 2009
23. line Memory Module DIP Dual Inline Package DMA Direct Memory Access DMI Desktop Management Interface ECC Error Checking and Correcting ECP Extended Capabilities Port EEPROM Electrically Erasable Programmable Read Only Memory EMC ElectroMagnetic Compatibility EMP Emergency Management Port EPP Enhanced Parallel Port ESD Electrostatic Sensitive Devices FPC Front Panel Controller FRU Field Replaceable Unit FSB 44 OptionsGuide RX20053 GAM GUI HDD HSC PC I O ICM IDE IRQ LAN LBA LCD LUN Abbreviations Front Side Bus Global Array Manager Graphical User Interface Hard Disk Drive Hot Swap Controller Inter Integrated Circuit Input Output Intelligent Chassis Management Identification Integrated Drive Electronics Interrupt Request Line Local Area Network Logical Block Address Liquid Crystal Display RX200 S3 Options Guide 45 Abbreviations Logical Unit Number LVD Low Voltage Differential SCSI MMF Multi Mode Fiber MRL Manual Retention Latch NMI Non Maskable Interrupt NVRAM Non Volatile Random Access Memory OS Operating System PCI Peripheral Component Interconnect PDA Prefailure Detection and Analysis POST Power ON Self Test RAID Redundant Arrays of Independent Disks RAM Random Access Memory ROM Read Only Memory RSB Remote Service Board RTC 46 Options Guide RX200 S3 Abbreviations Real
24. r screws Tighten the screws in diagonally opposite sequence see page 28 Reinstall the air duct Ensure that the hooks on the air duct see figure 8 on page 24 engage on the fan s rear panel Close the server plug in the power plugs and switch on the server as described in the chapter Completion on page 41f Options Guide RX200 S3 7 CD DVD Drive CAUTION Please observe the safety information in the ff The PRIMERGY RX200 S3 Server is equipped with a slimline bay intended for a CD DVD drive The mounting slot already contains an empty frame which must be removed for installing the CD DVD drive Figure 16 Removing the CD DVD frame gt Push the green spring button 1 gt With the other hand push the frame out towards the front 2 RX200 S3 Options Guide 33 CD DVD Drive Figure 17 Installing the CD ROM DVD drive _ gt Angle the drive as shown above and install it in the two lateral hooks see circles on the frame Figure 18 Fastening the CD DVD drive Fasten the CD DVD drive using the two screws see circles on the frame 34 Options Guide RX200 S3 CD DVD Drive Figure 19 Inserting the CD DVD drive gt From the outside slide the CD DVD drive into the bay 1 until it engages in the connector 2 RX200 S3 Options Guide 35 8 Controllers in Non Hot Plug PCI Slots CAUTION Please observe the safety information in the chapter Safety Instructions on page 11f
25. replaced with identical batteries or with a type recommended by the manufacturer see the Technical Manual for the system board under Related publications on page 49 e Do not throw batteries into the trash can They must be disposed of in accordance with local regulations concerning special waste e Replace the lithium battery on the system board in accordance with the instructions in the Technical Manual for the system board see Related publications on page 49 e All batteries containing pollutants are marked with a symbol a crossed out garbage can The marking also contains the chemical symbol of the heavy metal that determines the classification as a pollutant Cd Cadmium Hg Mercury Pb Lead Notes on handling CDs in CD ROM DVD drives CAUTION e Use only CDs in proper condition in the CD ROM DVD drive of your server to prevent data loss damage to the device or injuries e Therefore check each CD for damage cracks breakage etc before inserting it in the drive e Please note that any additional labels applied may change the mechanical properties of a CD and cause imbalance e Damaged and imbalanced CDs can break at high drive speeds data loss e Under certain conditions sharp edged pieces of broken CDs can penetrate the cover of the drive cause damage to the device and be thrown out of the device therefore causing injury to uncovered body parts particularly the face or neck 14 Options Guide RX2
26. s rear panel Figure 8 Hooks of the air duct gt Close the server plug in the power plugs and switch on the server as described in the chapter Completion on page 41f 24 Options Guide RX200 S3 6 Processors CAUTION Please observe the safety information in the chapter Safety Instructions on page 11ff Y CAUTION Processors are components which are extremely sensitive to electro static discharge and must be handled with caution When you take a processor out of its protective wrapper or out of a socket place it on an insulated antistatic surface with the smooth side down Never slide a processor over a surface 6 1 Installing a second processor The system board can be upgraded with a second processor CAUTION You may only use processors of the same type The second processor must have the same clock frequency as the first For dual processor mode use a suitable multiprocessor operating system gt Open the server as described in the chapter Preparation on page 17f Removing the air duct gt Lift the air duct up and off RX200 S3 Options Guide 25 Installing a second processor Processors Removing the heat sink dummy wW GOHI one eo ve a Sasa fees E E ICAO e bree ore O m E Fa Figure 9 oma ihe heat sink dummy gt Remove the two screws and lift out the heat sink dummy Installing the processor Figure 10 Opening the socket lever gt Release the socket lev
27. tandards EN 61340 5 1 ANSI ESD 20 20 il You will find a detailed description of handling ESD components in the 16 OptionsGuide RX200 S3 4 Preparation CAUTION Please observe the safety information in the chapter Safety Instructions on page 11ff 4 1 Pulling out removing the server gt Exit all applications and shut down the server correctly gt If your operating system has not switched off the sever press the on off switch gt Unplug the power plugs p p 2 O e PES p D ARRAY Figure 2 Pulling the server out of the rack gt Loosen the knurled screws 1 and pull the server carefully out of the rack 2 as far as possible RX200 S3 Options Guide 17 Pulling out removing the server Preparation If the server is difficult to reach in the rack after you have pulled it out remove it completely from the rack If you do not want to remove the server skip this page CAUTION There is no cable management for the server in the rack Before you remove the server from the rack you must therefore unplug all cables connected to the server from their sockets CAUTION At least two people are needed to lift the server out of the rack Figure 3 Removing the server from the rack gt Press the safety springs 1 on both sides and carefully pull the server forward a little 2 gt Pull the server off the rails and place it on a table or similar surface
28. y Manager Client Software User s Guide 11 Global Array Manager Server Software User s Guide RX200 S3 Options Guide 49 Related publications 12 13 14 15 16 17 18 19 20 21 50 Integrated Mirroring User s Guide PRIMECENTER Rack Technical Manual DataCenter Rack Technical Manual 19 Rack Technical Manual PRIMERGY ServerView Suite ServerView S2 Server management User Manual PRIMERGY ServerView Suite ServerView Server management User Manual PRIMERGY ServerView Suite RemoteView User Manual LSI Logic MegaRAID SAS Software User s Guide LSI Logic MegaRAID SAS Device Driver Installation Integrated SAS for RAID User s Guide OptionsGuide RX200 S3 Index A additional documentation 5 air duct 25 B batteries 14 C CD DVD drive 7 CD ROM DVD drive upgrade 33 controller 7 upgrade 39 cover installation 41 D dual processor mode 25 E EGB label 15 electrostatic sensitive devices 15 ESD 15 ESD label 15 exchange main memory 23 processor 29 H heat sink exchange 32 installation 28 removing the dummy 26 information material 6 installation cover 41 riser card holder 40 ventilation duct 28 RX200 S3 L light emitting diode LED 15 lithium battery exchange 14 M main memory 21 exchange 23 upgrade 7 23 meaning of the symbols 8 multiprocessor operating system 25 N notational conventions 8 notes on handling CDs

Download Pdf Manuals

image

Related Search

Related Contents

Logitech S 520 User's Manual  La parité mode d`emploi  JVC 2B00401C DVD VCR Combo User Manual  comist 72 dspgm comist 122 dspgm comist 180 dspgm  Behringer ADA8200 Quick Start Guide  Mamiya Aptus II User Guide  User manual - Marantz UK  Menu display function: - produktinfo.conrad.com  在庫 2009 取扱説明書  Proyectores de la serie D100  