1. Attention All operations which require the opening of the casing cables connection programming etc must be carried out by expert personnel during installation For any further operation which requires the casing to be re opened re programming repair or installation amendments contact the after sales assistance STATEUROP declares that the products WiWeather 443 868 are in compliance with the specifics of R amp TTE 99 5 EC EMC 2004 108 EC LVD 2006 95 EC Directives CE RAIN MONITOR SUN MONITOR WIND MONITOR CODE MONITOR C YRI SUN REG TX EM SUN SENSOR Rev 1 0 20 02 09
2. D flashing option selected LED Reference LED Off LED On 2 SPEED Wind Safety 25 Km h Pgm Wind Safety 3 WIND Wind Safety OFF Wind Safety ON 4 SUN Sun Sensor OFF Sun Sensor ON 5 RAIN Rain Sensor OFF Rain Sensor ON 6 TEST Test Sensors OFF Test Sensors ON 1 CODE Send RFID OFF Send RFID ON 1 CODE Sending of Radio Identifier The coupling of the Wireless Sensor to a control unit must be carried out as follows activate the Wireless Sensor program ming procedure on the control unit See control unit technical manual with the SEL key position yourself on the flashing of the CODE LED and press the SET key for about 1 2 seconds at the same time the Sensor will send an identifying code sig nalled by the flickering of the CODE MONITOR LED Check that in the coupled control unit there is confirmation of the occurred Sensor programming see control unit technical manual In this way the Wireless Sensor is coupled to the control unit and it will send to the same controls dependant upon the meteorological conditions Repeat the operation in case the same Sensor is to be pro grammed on other control units 2 SPEED Programming of Wind Safety threshold Display of the programmed Wind threshold The display of the wind Safety threshold selection is carried out as follows with the SEL key position yourself on SPEED LED the LED will start to double flash for the number of times equal to the wind Safety threshol
3. WiWeather Wireless Sensor Wind Sun and Rain Wireless Sensor to be coupled with STATEUROP electronic control units for the automation of rolling window shutters and sun blinds Mod WiWeather 433 Mod WiWeather 868 433 92 MHz 868 3 MHz TecunicaL DATA Power supply 230V 50 60Hz 3W max Working temperature 10 55 C Working frequency see model Sensitivity Anemometer 5 40 Km h Sun Sensor Sensitivity 5 40 Klux 240x185x110 mm PC UL94V 0 IP54 Packaging dimensions Container CoNNECTIONS OF THE CN1 TERMINAL BOARD 1 230V Line input Phase 2 230V Line input Neutral IniTIAL FUNCTIONING CONDITION The device can only work in conjunction with one or more STATEUROP electronic control units prearranged for radio re ception of information relating to the state of the sensors For the functioning it will be necessary to carry out the program ming operation of the Wireless Sensor on the control unit to which it will be coupled see par CODE Sending of Radio Identifier In the default factory setting each Wireless Sensor example produced has a different identifier Wino Sensor FUNCTIONING The device will send to the control unit to which it has been coupled a closing control every time the set Wind threshold is exceeded Sun Sensor FUNCTIONING The device will send to the control unit to which it has been coupled a d
4. d in the memory to every double flash of the SPEED LED corresponds an increase of 5 Km h example 5 flashes of SPEED LED 25 Km h Selection of the wind Safety threshold from 5 to 40 Km h The sensor is supplied with the wind Safety intervention threshold equal to 25 Km h SPEED OFF LED The programming of the wind Safety threshold selection is car ried out as follows with the SEL key position yourself on SPEED LED and press the SET key to start the programming procedure at the same time the SPEED LED will start to double flash every double flash of the SPEED LED corres ponds to an increase of 5 Km h once the desired threshold has been reached press the SET key the selected value will be memorised at the same time and the SPEED LED will re main on example 5 double flashes of SPEED LED 25_ Km h It is possible to repeat the operation in case of an incorrect pro gramming Rev 1 0 20 02 09 3 WIND Wind Sensor ON OFF Deactivation of the Wind Sensor The device is supplied with the Wind Sensor enabled WIND ON LED The deactivation of the Wind Sensor can be carried out as fol lows with the SEL key position yourself on the flashing of the WIND LED and press the SET key for an instant at the same time the WIND LED will switch off and the Wind Sensor deac tivation will be complete It is possible to repeat the operation to activate the Wind Sensor 4 SUN Sun Sensor ON OFF Enabling the Sun Sensor The
5. device is supplied with the Sun Sensor disabled SUN OFF LED The enabling of the Sun Sensor can be carried out as follows with the SEL key position yourself on the flashing of the SUN LED and press the SET key for an instant at the same time the SUN LED will remain on and the Sun Sensor enabling will be complete It is possible to repeat the operation to disable the Sun Sensor 5 RAIN Rain Sensor ON OFF Deactivation of the Rain Sensor The device is supplied with the Rain Sensor enabled RAIN ON LED The deactivation of the Rain Sensor can be carried out as fol lows with the SEL key position yourself on the flashing of the RAIN LED and press the SET key for an instant at the same time the RAIN LED will switch off and the Rain Sensor deactiv ation will be complete It is possible to repeat the operation to activate the Rain Sensor 6 TEST Test Sensors ON OFF The device is supplied with the Wind Sun Rain Test Sensors disabled TEST OFF LED The activation of the Wind Sun Rain Test Sensors can be carried out as follows with the SEL key position yourself on the flashing of the TEST LED and press the SET key for an instant at the same time the TEST LED will switch on and the activa tion of the Wind Sun Rain Test Sensors will be complete It is possible to repeat the operation to disable the Test Sensors Anemometer Test manually rotate the Anemometer blades and at the same time the WIND MONITOR LED will
6. f the in formation relating to each sensor LED Reference CODE MONITOR LED Off Info OFF Info OFF Info OFF Info OFF LED On Info ON Info ON Info ON Info ON WIND MONITOR SUN MONITOR RAIN MONITOR RESET In case it is necessary to reset the control unit default factory configuration press the SEL and SET keys together so that all indicator LED switch on and off at the same time Rev 1 0 20 02 09 IMPORTANT FOR THE INSTALLER The device must be permanently connected to the power supply network and not have any type of sectioning device of the 230Vac electric line it will therefore be under the care of the installer to provide the plant with a sectioning device It is necessary to install a single phase switch with over voltage category III It must be positioned so as to be protected against accidental closures For connections power supply use flexible cables under in sulating sheath in harmonised polychloroprene HOSRN F with minimum section of the conductors equal to 0 75 mm The connection cables must be fixed by assembling cable clamps supplied with the product The device at the time of installing must be carefully man aged ensuring to have assembled the composing parts correctly Pay particular attention to the ceramic plate and to the connecting flat When re closing the box the latter must fold on itself in an orderly manner Itis very importa
7. nt to establish the exact location so that the product is exposed to the same atmospheric agents as when it is controlled Ensure that the device remains inclined at about 45 de grees fixing area at top round extremity of the box at bot tom Do not paint or varnish the sensitive surface of the control unit The dirt which builds up on the rain sensor surface limits the sensitivity it is therefore recommended to clean it once or twice a year with a damp cloth after having disconnected the automation For a correct functioning it is recommended to always use only one device for one or more control units installed in an action range of 20 meters Always carry out the tests of the sensors to ensure the cor rect functioning of the installed system TEST RAIN si SUN S WIND zo SPEED CODE le SEL SET IMPORTANT FOR THE INSTALLER The device must never be used by children or persons with reduced physical psychological abilities unless supervised or trained on the functioning and the use modalities Do not allow children to play with the device ATTENTION keep this instruction manual and respect the important safety prescriptions contained herein The non com pliance with the prescriptions may cause damages and seri ous accidents Frequently examine the plant to detect any signs of dam aging Do not use the device if a repair intervention is neces sary
8. ownward control after 10 minutes of brightness higher to the threshold selected by means of the VR1 trimmer and displayed through the switching on of the SUN MONITOR LED it will send an upward control after 10 minutes of bright ness lower than the selected threshold Regulation of sensitivity to the Sun 5 40 Klux The device allows to regulate the intervention threshold due to brightness by means of the VR1 trimmer The switching on of the SUN MONITOR LED on the device indicates that the Sun intensity exceeds the selected intervention threshold in this way we will have a reference to the current light conditions to establish the desired one Rain SENSOR FUNCTIONING The device will send to the control unit to which it has been coupled an upward control as soon as the sensitive part of the rain sensor is wet by water signalled through the switching on of the RAIN MONITOR LED PRocGramminG Keys AND Inpicaror LED SEL Key selects the type of function to memorise the choice is indicated by the flashing of the LED By repeatedly pressing the key it is possible to position oneself on the desired func tion The selection remains active for 15 seconds displayed by the flashing LED after which the control unit returns to the ori ginal status SET Key carries out the programming of the function chosen with the SEL key Indicator LED LED on option memorised LED off option not memorised LE
9. switch on signalling the radio sending of the necessary information to the previously configured coupled control unit signalled by the flickering of the CODE MONITOR LED controlling the ascent for 5 sec Sun Sensor Test rotate VR1 trimmer as far as possible clock wise in position and at the same time the SUN MONITOR LED will switch on signalling the radio sending of the neces sary information to the previously configured coupled control unit signalled by the flickering of the CODE MONITOR LED controlling the descent for 5 sec Rotate the VR1 trimmer VR1 anti clockwise in position and at the same time the SUN MONITOR LED will switch off signalling the radio sending of the necessary information to the previously configured coupled control unit signalled by the flickering of the CODE MONITOR LED controlling the ascent for 5 sec Rain Sensor Test wet the sensitive part of the Rain Sensor and at the same time the RAIN MONITOR LED will switch on signalling the radio sending of the necessary information to the previously configured coupled control unit signalled by the flickering of the CODE MONITOR LED controlling the ascent for 5 sec Completed the test ensure to have dried the sensitive part of the rain sensor before using the control unit in the normal func tioning SENSORS MONITOR The control unit presents four monitor indicator LED with which it is possible to display the radio transmission o