Home

SNR-CI-M Series

image

Contents

1. 15 SNR CI M Series I Important Safeguards 1 All the safety and operating instructions should be read before the units is operated 2 This unit should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power supply you plan to use consult your appliance dealer or local power company For units intended to operate from battery power or other sources refer to operating instructions 3 During the course of transportation storage and installation the product should be avoided from incorrect operations such as heavy pressing strong vibration etc which can cause damage of product as there are sophisticated optical and electronic devices inside the machine 4 Do not attempt to disassemble the camera In order to prevent electric shock do not remove screws or covers There are no user serviceable parts inside LO ae y 47 gt 5 Always follow all electrical standards for safety when it is in operation Adopt the particular power supply which is provided with the unit RS 485 and video signal should keep enough distance with high voltage equipments and cables when they are in transmission Precautions for anti lightning and anti surging should be taken if necessary 6 Do not operate it in case temperature humidity and power supply are beyond the limited stipulations 7 Do not let the camera aim at the sun or the object with extreme light
2. 2 6 2 AUTO PAN END POS set end position of auto scan between two points To move the holder by joystick after entering and to return by CLOSE button 2 6 3 RUN AUTO PAN Auto scan function between two points First of all you must set the start position and the end position of auto scan If the start position is just the end position it means 360 scan The speed of auto scan has six grades FAST NORMAL SLOW FAST NORMAL SLOW in which the first three grades are scan less than 180 while the later three grades larger than PROGRAM 180 Adjust speed by PAN LEFT PAN RIGHT and operate and exit by OPEN button AUTO PAN START POS The start position and the end position of auto AUTO PAN END POS scan are set by options 1 and 2 in this RUH AUTOCEAN SLOV submenu SET TITLE 61 SET PATROL H1 RUH PATROL B1 2 6 4 SET TITLE to edit titles of preset position Only previous 63 preset points have their titles RECORD PATTERN Select no of preset point by PAN LEFT PAN RUN PATTERN RETURH SNR CI M Series RIGHT enter into edit by OPEN button and exit edit by CLOSE button Operations under edit state can be seen later 2 6 5 SET PATROL to edit data for multi points patrol Select no of patrol by PAN LEFT PAN RIGHT enter into edit by OPEN button and exit edit by CLOSE button Operations under edit state can be seen later 2 6 6 RUN PATROL to run multi points patrol function Select no of patrol by PAN LEFT PAN RIGH
3. 2 Kg Weight 4 Kg with aluminum alloy ball Opposite Humidity 10 75 Environment Temperature 0 C 40 C Scan System 15 625 KHz H 50Hz V Horizontal 480 Horizontal amera Signal to Noise gt 48 db Function Shutter 1 3 1 10000 sec Sensitivity 0 01 1 lux F1 6 Zoom Rate 18 X Optical and 12 X Digital Lens Iris Auto Manual Parameter Focus Auto Manual Dome Pan Speed 0 300 s Function Tilt Speed 0 120 s SNR CI M Series Network IP Cameras User Manual Preset 128 presets max Auto Cruise At best 6 cruises Pattern 40 sec Troubleshooting Software part in software manual Problems Possible Causes Remedies Power supply fault Replace Ng aahon when Bad connection of the power is switched Correct power on Transformer damaged Replace Abnormal Mechanical failure Repair self check s Images with Camera inclined Reinstall TONS Power supply not enough Replace Video signal fault Reinstall Normal self check but no Bad connection of the video Press to connect well images Camera damaged Replace RS485 bus bad connection Check ine Jede connection Normal self check but out Dome ID setup is wrong Reselect of control Protocol setup is wrong Reset and Switch ON again Bad connection of the video Press to connect well Vague image Power supply not enough Replace Self check error Switch ON
4. M Series Figure 4 3 b Ceiling Figure 5 Red Black Power Supply Audio In GND Audio Out GND Alarm Out GND GND 2 channel Alarm In Figure 6 Dome down lead Notice SNR CI M Series Network IP Cameras User Manual will be made by client s order 4 To Ensure a Smooth and Successful Installation You Should 1 Have electrical work to comply with latest national electrical code national fire code and all applicable local codes and ordinances 2 4 Coordinate with other trades to avoid interference nag The lines of the POWER SUPPLY and the LAN is the default other down leads 3 Verify existing conditions on the site and coordinate with owner side to ensure necessary utilities available D 4 Copy all related plans specifications shop drawings and attachments to schedule and coordinate related work 5 Thoroughly review the project to ensure that all jobs should meet or exceed the above requirements Contact with the CCTV Project Coordinator to draw attention in case alleged discrepancies occur VI Technical data table Image Inductor 1 4 Color CCD Pixels 752H X582 V 440000 pixels PAL In Phase System In Phase Inside Video Output 1 0 Vp p 75 Q White Balance Auto Manual Specificatio Power Supply 24V 10 1 25A with fan heater 30 VA with fan heater ns Power Consumption 15 VA indoor
5. 16 139 42 SNR CI M Series Network IP Cameras User Manual nag 140 20 6 32 9 51 15 129 39 150 18 5 30 9 47 14 120 36 160 17 5 28 8 44 13 113 34 170 16 4 26 7 42 12 106 32 180 15 4 25 7 39 11 100 30 190 14 4 23 7 37 11 95 28 200 14 4 22 6 35 10 90 27 APPENDIX III Wire Gauge Conversion Chart Bare wire diameter metric Bare wire cross sectional size nihi iin MM a Approximate Approximate un 0 050 43 47 0 00196 0 060 42 46 0 00283 0 070 41 45 0 00385 0 080 40 44 0 00503 0 090 39 43 0 00636 0 100 38 42 0 00785 0 110 37 41 0 00950 0 130 36 39 0 01327 0 140 35 0 01539 0 160 34 37 0 02011 0 180 33 0 02545 0 200 32 35 0 03142 0 230 31 0 04115 SNR CI M Series Network IP Cameras User Manual 0 250 30 33 0 04909 0 290 29 31 0 06605 0 330 28 30 0 08553 0 350 27 29 0 09621 0 400 26 28 0 1237 0 450 25 0 1602 0 560 24 24 0 2463 0 600 23 23 0 2827 0 710 22 22 0 3958 0 750 21 0 4417 0 800 20 21 0 5027 0 900 19 20 0 6362 1 000 18 19 0 7854 1 250 16 18 1 2266 1 500 15 1 7665 2 000 12 14 3 1420 2 500 4 9080 3 000 7 0683 18
6. OP L ON H1 LINE ON point is called The modification of title of preset point is set on PROGRAM option TITLE POS Line 10 Line 1 is at the top of screen to set the display position of title of preset point from Line 1 to CAM DISPLAY when it is set at ON the camera screen will be opened RETURN to return to MAIN MENU CAMERA SETUP SLOW SHUTTER frame accumulation with two options Manual Automatic When camera screen is opened under automatic state ASS displays on screen BACK LIGHT ON OFF ICR SHOT low shooting ON AUTO IRIS setup of automatic iris AUTO MANU D ZOOM setup of digital zooming ON OFF FOCUS backlight compensation SO Gos CM ok setup of automatic focusing AUTO MANU SLOWSHUTTER BACK LIGHT ICR SHOT IRIS b 200H FOCUS WB SET OF CAM RETURH CAMERA SETUP AUTO DFF AUTO AUTO ON AUTO ATW WB SET setup of white balance ATW INDOOR OUTDOOR ONEPUSH AUTO MANU MENU CAM blank RETURN return to MAIN MENU 2 4 CONTROL SETUP CONTROL SETUP nag to enter the submenu of display of the screen by which AUTO FILP ALARH PRESET PIC HOHE OPTION RETURN OM OM HOVE SNR CI M Series 2 4 1 AUTO FLIP 180 automatic flip of dome camera ON OFF 24 2 ALARM blank 2 4 3 PRESET PIC if image is followed when calling preset point or making tour FREEZE when switching scene to freeze image and to recover otherwi
7. SNR CI M Series NETWORK HIGHSPEED DOME MANUAL Please read the operation manual carefully before installing and using this unit SNR CI M Series SAFETY PRECAUTIONS RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRICAL SHOCK DO DOT OPEN COVERS NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL The lighting flash with a arrowhead symbol in an equilateral triangle is intended to alert the user There is uninsulated dangerous voltage presence near by the product s enclosure which may be risk of to persons The exclamation point within an equilateral triangle is intended to alert the user to reference of the important operating and maintenance servicing instructions SNR CI M Series THE PRODUCT CODE MARKED ON THE BOTTOM COVER PLEASE FILL THE CODE IN THE FOLLOWING BLANK PLEASE SAVING THIS SPECIFICATION CAREFULLY SO THAT CHECKING MODEL PRODUCT CODE SNR CI M Series INDEX Important Safeguards vs a ca ds a a oa Oe ee See a AR tae 5 Lle Description of Functions ar a eae ge 6 III Setup of the Menu of the Dome 7 IV Setup of the Dome 11 V The Installation of the 11 Vi Technical data Table asar A A ea 14 VII Troubleshooting Software part in software manual
8. T run and exit by OPEN button 2 6 7 RECORD PATTERN This pattern can consist of any standard pan and tilt or lens command Presets flip digital zoom proportional pan and turbo are not allowed in a pattern The pattern length is 40 seconds in maximum To return when 40 seconds expire or by push CLOSE button 2 6 8 RUN PATTERN to self learn loci of tour To exit the menu after running or to stop running by joystick 2 6 9 RETURN return to Main Menu 3 Appendix to the Menu 3 1 Operation of Edit State of Multi Points Patrol When entering into edit state the screen displays as follows NO serial No of patrol position NO POS SP TM POS SP TH POS No of preset position SP leaving speed TM dwelling time After entering into edit area screen shows as follows Edit Area data of 2 patrol position appears on one line SEQ 01 It means the set No 1 patrol SEQ 81 CLOSE EXIT CLOSE EXIT Push CLOSE to exit edit state Both top and bottom lines display prompt and information of each patrol is displayed on the middle of the screen Data of 2 Patrol points appears on one line Move cursor by PAN LEFT RIGHT and modify data by TILT UPIDOWN Press buttons for one second to speed up operation Press CLOSE button to exit edit state and store modifications The program will search the position of the first of POS store dada before it and regard data after it as invalid In above figure the program store
9. again Dome camera out of control Bad connection of control Press to connect well Bad control of matrix Switch ON again nag SNR CI M Series Network IP Cameras User Manual nag Appendix l The Cleaning of Clear Down Cover To obtain constant clear videos user should clean the down cover periodically e cautious when cleaning Hold the down cover ring only to avoid direct touch to the acrylic down cover The acid sweat mark of fingerprint will corrode the coating of down cover and scratch on down cover will cause vague images e Use soft dry cloth or the substitute to clean the inner and outer surfaces e For hard contamination use neutral detergent Any cleanser for high grade furniture is applicable Appendix II Wire Diameter and Transmission Distance Comparison Chart Wire diameter mm Transmission dons 0 8000 1 000 1 250 2 000 Power VA 10 283 86 451 13D 716 218 1811 551 20 141 42 225 68 358 109 905 275 30 94 28 150 45 238 72 603 183 40 70 21 112 34 179 54 452 137 50 56 17 90 27 143 43 362 110 60 47 14 75 22 119 36 301 91 70 40 12 64 19 102 31 258 78 80 35 10 56 17 89 27 226 68 90 31 9 50 15 79 24 201 61 100 28 8 45 43 71 QD 181 55 110 25 7 41 12 65 19 164 49 120 23 7 37 11 59 17 150 45 130 21 6 34 10 55
10. ation e Description of Electronic Shutter it is fixed on 1 50 sec after initialization when the camera is switched on and the digital 50 appears on the screen f Setup of Image Effect the camera works on OFF state under normal condition and no image effect symbol appears on the screen When B amp W appears on the screen it means the camera is on black and white state AE Mode setup of Manual Automatic Zero Illuminance It is used only when the external brightness is extremely low Normally the camera works on the automatic state In case the external brightness is lower than 1Lux the camera can be switch to the Zero P Us Illuminance state automatically and icon appears on the screen You can also set the Zero Illuminance state manually Setup of the Menu of the Dome Camera 1 Basic Operation of the Menu Encl Software manual 1 1 The main menu will be opened when Call Preset 64 or Call Preset 1 twice in 4 minutes 1 2 When the menu is displayed on the screen operate UP DOWN to move the cursor to the option to be set operate LEFT RIGHT to modify the content or the order to enter this option 1 3 Keep the joystick in one direction for over 1 second to speed up operation 1 4 All setups on the menu couldn t be lost even power failure happens 1 5 Special utilizations can be seen on the descriptions of functions of the menu in detail 2 Se
11. iable PAN TILT a Turning 360 horizontally and continuously with unlimited positions and an adjustable speed from 0 2 300 rad s turning 0 90 vertically with a speed up to 120 rad s b Running stably at low speed with super lower noise Pictures have no shaking c Automatic 180 flip and panoramic monitoring without blind point the location precision up to 0 1 2 High Intelligent Degree a As much as 128 preset positions can be preset with powerless memory b The camera can scan horizontally between two points and scan speed can be modified The positions of linear scan are optional and the dome camera can scan the range larger or smaller than 180 between any two points with adjustable speed c Six sets of programmable tour locus with 16 position each set The running speed and the detention time are adjustable respectively d The dome camera can simulate the PTZ route operated by you in 40 seconds by the self learning function of the locus with powerless memory e Character Overlapping The humane structure of the menu makes all setups and programming of the dome camera more convenient and easy f Proportional pan function The speed dome will depend on the amount of zoom At telephoto zoom settings the pan and tilt speeds will be slower for a given amount of joystick deflection than at wide zoom settings This keeps the image from moving too fast on the monitor when there is a large amount of zoom This slowing d
12. oes not happen when going to a preset but does occur in turbo mode when high zoom is selected The minimum pan and tilt speeds are 0 1 degree per second at full zoom g The Integrated Multi Protocol Multiple communication protocols are integrated inside the dome camera with selectable baud rate from 2400 bps to 9200 bps 3 Functions of the Camera icons can be displayed on the screen when the option 6 SNR CI M Series DISPLAY of the camera is ON a Description of the Focus Control Mode user can adjust the focus of the camera manually When the camera is on near focus the icon 37 appears on the screen when on the nearest state the icon amp appears while on the far focus the icon appears b Description of Backlight Compensation when the object to be shot is dark and looks dim the user can open the backlight compensation according to actual need and the icon appears on the screen c Description of White Balance when the image has color distort on the screen the user can set different modes by a There are 6modes for options D Indoor Mode amp 2 Outdoor Mode 3 Touch Mode EX Automatic Trace of White Balance ATW Manual WB MAN Automatic Mode d Description of ZOOM Control user can pull near or push far the lens according to actual conditions and the symbol W LE T appears on the screen in which the front part means optical multiplication while the rear part means digital multiplic
13. s previous four points with settable range from 1 to 63 and from 65 to 128 When of POS appears the tour range is ended The settable range of SP is from 0 to 8 0 and 1 are the same with fastest speed while 8 has the lowest speed The settable range of TM is from 0 to 99 seconds 3 2 Operation of Title of Preset Point in Edit State When entering into edit state the screen displays as follows In the figure we find the preset point is No 1 with title of NO TITLE Move cursor by PAN LEFT RIGHT and modify data by TILT PRESET 81 UP DOWN Press buttons for one second to TITLE NO TITLE CLOSE ERIT SNR CI M Series speed up operation Press CLOSE button to exit edit state and store modifications The title of preset point has 8 characters in maximum such as 0 9 A Z and space Note the first character should be 0 9 or A Z otherwise it means to delete the title of the preset point and when preset point is adjusted only NO XXX spears without title to be displayed IV Setup of the Dome Camera 1 System connection 1 The system map of the dome SWITCH BOARD INTERNET V The Installation of the System 1 Installation manner a Hanging SNR CI M Series 1 Open the packing take out the dome and the accessories 2 Fix the dome with the bracket well as Figure 4 1 amp 4 2 3 Fix the bracket on the wall as Figure 4 3 TT TA i Figure 4 2 SNR CI
14. se MOVE when switching scene no image frozen 2 44 HOME OPTION enter the submenu of automatic home function HOME OPTION 2 4 4 1 AUTO HOME when it is set at ON home E function is available namely the dome eee ee y 2 HOME POS 81 camera will return HOME if user has no 3_DWELL TIME 85 HIN action in a period of time The dome camera amp RETURH shall not return HOME if it is on tour state If no HOME is needed when the dome camera is stopped set the option at OFF 2 4 4 2 HOME POS HOME means return home For example to set one scene as HOME call the scene first and set it as preset point then call out the menu to enter into this submenu change figures after HOME POS into 5 If automatic HOME function is needed do not forget to set AUTO HOME at ON The preset points of HOME POS are from 1 to 63 and 65 to 128 2 4 4 3 DWELL TIME to set the time of automatic HOME which means the camera shall return HOME if it is not controlled in a period of time which can be from 1 to 99 minutes 2 4 4 4 RETURN return to the menu one level higher 2 4 5 RETURN return to MAIN MENU 2 5 CAMERA MASK SET CAMERA MASK SET 2 5 1 MASK PRIVACY blank Asi EE TUNI EE 2 5 2 MASK SHADE blank HASE SHADE BLACK 2 5 4 RETURN return to Main Menu RETURH 2 6 PROGRAM Options 2 6 1 AUTO PAN START POS To set start position of auto scan between two points To move the dome camera by joystick after entering and to return by CLOSE button
15. tup of the Menu 2 1 MAIN MENU SNR CI M Series Network IP Cameras User Manual 2 1 1 2 1 7 2 1 8 2 1 9 DISPLAY SETUP ID display title display of preset point and display of camera screen can be set CAMERA SETUP to enter the submenu of setup of normal data of camera CONTROL SETUP to enter the submenu of setup of control data over the dome camera CAMERA MASK SET to enter the submenu of setup of mask function of camera PROGRAM to enter the setup of enhanced function of dome camera PAL CAMERA PAL NTSC switching to suit the camera CAM DEFAULT SET DOME RESET to reset the dome camera EXIT to quit the main menu 2 2 DISPLAY SETUP 2 2 1 2 2 2 223 2 2 4 2 2 5 2 2 6 2 3 2 3 1 2 3 2 2 3 3 2 3 4 235 2 3 6 2 3 7 2 3 8 2 3 9 ID DISPLAY when it is set at ON address of dome camera appears on the screen such as CAM 001 The default setting is ON ID POS to set the display position of address on one of following corners TOP L TOP R BOTT R and BOTT L TITLE DIS when it is set at ON the title of preset point appears on the left of screen such as NO 001 ABCDEFGH when the preset MATH HEHU DISPLAY SETUP CAHERA SETUP CONTROL SETUP CAHERA MASK SET PROGRAM PAL CAMERA CAH DEFAULT SET DOHE RESET EXIT SO Goo AAA to reset default setup of camera DISPLAY SETUP ID ID TITLE DIS TITLE POS CAH DISPLAY RETURH DISPLAY POS ON T
16. whatsoever it is switched on or not Do not let the camera aim at or monitor bright and standstill object for a long time 8 Do not use aggressive detergent to clean the main body of the camera Wipe dirt with dry cloth If needed mild detergent can be used suitably 9 Operate the intelligent speed dome camera with great care to avoid shock or vibration It operate incorrectly the Speed Dome could be damaged 10 Do not place this unit on an unstable stand tripod bracket or mount The unit may fall causing serious injury to a person and serious damage to the unit Use only with a stand tripod bracket or O fax lt mount recommended by the manufacturer or sold with the product Any mounting of the unit should follow the manufacturer s instructions and should use mounting accessory recommended by manufacturer 11 If necessary use a commercial lens cleaning paper to clear the lens windows Gently wipe the lens window until clean SNR CI M Series II Description of Functions The network dome camera is a high tech surveillance product which integrated network transmission high definition color camera P T decoder CPU and memory chip Fast installation construction more easy to install enhanced the reliability of the system Also it is easy to service The network dome camera achieves the long distance control by network and it 1s suitable for various situation 1 Integrated Speed Var