Home

Printed Documentation - Support

image

Contents

1. the orders Vena working with the case QIR Reject option rejects the selected order ds the list La Rarer sere model After you click Accept button the Accept the selected orders form popups 33 Printed Documentation Accept Selected Orders i Accept the selected order s Pass this message back to the dient Order is accepted Accepting the selected orders m The selected order will be marked with the padlock Once you click Accept you get the message Accept the order The sender of the order was not found in your sites list Control panel will be opened and the sender will be automatically added Please make changes if itis required and dose control panel saving the changes Click OK This will automatically open the Control panel Sites form Fill in the information and click Save 34 Ortho Database Orthodontics System Control Panel Site e H o Home Back Save Help Administrative settings Sites Tasks Edit Site Import site s from server Import sites from Excel ID document Site Address 1 Address 2 Zip code Hide inactive items aye Add ae Copy Delete E Move up Y Move down Recycle bin Pa Hramba lee Filling in the Sites information for the order in the Ortho Control panel When you click the Preview button the Order 3D Preview form appears 35 Printed Documentation Preview form
2. Feature 2 fe g ID tag on Component 5 Ortho Database 1 1 Getting Started 1 1 Getting Started This section describes the principles of managing the models in ApplianceDesigner The chapter is divided into three parts the first part is about a new patient entry the second is for working on already created cases and the third is for running an independent session with no patient database attachments 1 1 1 Executing ApplianceDesigner lianceDesigner is started by double clicking the ApplianceDesigner desktop icon or via the Windows Start menu Start gt Programs gt 3Shape gt ApplianceDesigner When the application starts the following screen appears ApplianceDesigner sa Application Models View Help E yO gt Printed Documentation 1 1 2 Creating a New Database Entry 1 1 2 1 New Patient Before starting an analysis session a patient database needs to be created To create a new patient click on the Patient model set E button in the Main toolbar and select the New patient button A New patient info form will appear E Open patient case Ane ea Je Patients Ja Patient Selection New patient info Patient information Patient id Patient external 1d SSM First name Last name Address City Country Clinic 1 2 2 New Model Set The New model set step creates the set for the current patient by allowing you to fill in a i
3. The buttons in the Visualization toolbar are presented in table below View The view buttons allow you to switch between a number of predefined viewpoints Front view Rear view Right side view Left side view Top view Bottom view Ao Zoom all Sets the model to the default view size and position on the screen a leaving its current rotation angle intact Y Additional plane view allows to view the models according to predefined planes Y Cross section Allows to create the 2D cross section of the model at any stage of the workflow Fi Show undercuts Marks the undercuts with the colors according to the set color scheme amp 3D measurements Allows you to perform measurements on the model EL articulator simulates the movements of the model in the articulator Axis locked rotation Locks the rotation to the x y or z axes 40 2 Appliance Designer User Interface cy Pan view When selected right click and drag to pan the view Y zoom view When selected right click and drag to zoom in and out Show material and shadows Marks the cast segments with the corresponding material colors and toggles on and off the function of shadow visualization H show wireframe Shows the triangulation of the virtual casts show as transparent Changes the degree of transparency of the virtual casts gt Show perspective Transforms the model into a realistic 3D object where the distant objects appear
4. After loading model it is possible to 7 Add Align model NS align it Right click it and select the Add Modify model Add Align model option in the popup menu The Registration window appears E Add ID Tag 89 Printed Documentation Follow the instructions at the top of the Registration window Registration The Reference model button opens the list of the available models Identify 3 or more You can select the type of alignment e Surface 1 point Indicate single corresponding points on each model for alignment and optionally select the surface to align with the help of the Selection Tools e Surface 3 point Indicate three corresponding points on each model for alignment and optionally select the surface to align using the Selection Tools e Direct 3 point Indicate three corresponding points on each model for alignment This method does not use the surface information Reference model 2 Model 3 Selection 90 4 Components Tab tools The selection tools can be used in any order and combination They include the following A Unselect all Unselects all selections Reduce selection Reduces the selected area by El excluding the neighboring areas from the selection BB een selection Extends the selected area by E inver the neighboring areas to the current selection na E cas the unselected areas of the surface an selection operation Paint selection Use
5. The central point moves the plane around the model leaving the Slope of the plane unchanged 5 Plane translation the control point located on the blue circle defining the plane T Fe pa dit HE i f p ii 4 E a e H Ei ae FEG SHES H4 i ii min 47 Printed Documentation moves the plane back and forth without changing its slope Adjust the plane position by pulling the Plane offset slider P the Temporary plane window 2 O O Length measurement requires two points Measures length from point to point It is possible to customize the view of the measurement by right clicking it and selecting Properties from the popup menu pe Al a AT Select Color or the measurement set the Line width from the drop down menu and indicate the Value by entering the parameters manually in the appropriate editbox You can move the measurement along the grid by dragging the control point turn when selected It is possible to annotate the control point and the measurement if selected turns Mic Right click the desired object select Annotate from the popup menu and enter the annotation text in the popup window 48 3 Interactive Tools Angle measurement requires three points With angle measurement the second f point becomes a vertex of the angle There are some extra options for Angle s measurement in the Properties option It is
6. 2 Trios orders tree enlists the folders with the currently available orders 3 It is possible to open the list of options duplicating the Operation buttons by right clicking the desired orders in the List of orders Patient ID Patientname Clinic ID Model setID Modelset Model setc 2013 TRIOS LN 2013 06 2 OperatorMax TRIOS ord PS 2013 06 22 Default op 36 2 Appliance Designer User Interface 2 ApplianceDesigner User Interface The user interface comprises of the following four sections as indicated on the image below 1 Main toolbar 2 Functional panel 3 Session window 4 Visualization toolbar ls ApplianceDesigner Prototype not for clinical use CAProgramDatal35hapeOrthoData 2012 1 Beta 2001 1 Appliances 2012 05 21 1 el eS Application Models View Help El x ap ALA FE 3shape gt Actual fra me rate 13 fps Achievable OpenGL frame rate 97 9 fps The following sections describe all the user interface components in details 2 1 Main Toolbar The Main toolbar contains functionality relevant to managing the analysis and the processes of design 37 Printed Documentation A Patient model set Loads previously created patient model sets from the patient Pp database I Templates manages the templates for the program O revua all components allows to rebuild all the loaded components Gee models Opens model s required for i
7. arrow by each button It is possible to observe the changes you perform in colors Activate the Difference map by clicking the appropriate button Open the drop down menu by clicking the black arrow to view the legend and customize its view Faa Attachments Attachments are 3D models that can be added to or subtracted from the surface of any model or simply used as visual guides for the output models or appliances Note attachment should be added to an attachment group through the Ortho Control Panel before they are available in the Appliance Designer Click on the desired area and place the attachment Customize it using the red green and blue control points 95 Printed Documentation Rotates attachment 4 Changes the height of round its axis attachment Moves the attachment in 5 relation to the surface of the appliance Changes the width of attachment Moves the 3 attachment back and forward Note Attachments properties can be edited in the Ortho Control Panel it is for example possible to lock the scaling parameters i e 2 and 4 in the image above so the attachment s geometry cannot be changed during the design process This is particularly useful when attachments are standard physical parts that will be mounted in the designed appliance It is possible to select the Group type of Attachment and Default orientation by choosing them from the corresponding drop down menu in the Attachment s
8. dialog box Click the New model set button to get the New patient model set info window Ortho Database Open patient case DA El 28 Patients BEPERA EF Paa selection Model set ID Status Model set Model set operator Model set comment E 4 Jane Doe E 2 John Doe 2013 Unprepared OperatorMax TRIOS order comme New patient model set info TE Model set information Attach model Patient id 2013 06 26 13 59 TRIOS_LN_001 Model set id Model set external id Comment Operator Model set date ff 4 2013 Scan date ff 4 2013 Scan time 21726 Ph In the section Attach model you can select the new model set intended for import Click Create to save the entered data The description of the fields in the form is provided below Model set ID Corresponds to the ID string that uniquely identifies the model set for a particular patient Comment Any comments related to the order or the model can be added here Operator Fill in the name or the code of the operator performing model set analysis Model set date The date the model was created the default date can be modified Scan date and Scan time The Date and time the scan was taken the default date and time can be modified Note The information specified in New patient and New patient model set appears at the bottom left corner of the session window for reference 1 1 2 3 Open Models for Patient It is possible to open models for p
9. open the Templates window You can Add to the list of the Existing templates Type the Name of the new suit and click OK Use the operation buttons to the right to customize the section It is possible to Export Import by selecting the path of export import y il efault 39 Printed Documentation Note while a template will allow to save and reapply all design parameters and components and features you will still need to define the components e g cutting splines or control points on the new patient s model set 2 2 Visualization Toolbar Finding the right point of view to work on a 3D model most effectively can be difficult and time consuming ApplianceDesigner comes with a set of tools aimed at helping you find the most advantageous visualization The visualization tools are grouped in the Visualization toolbar and allow to e Rotate the 3D view to a preset angle this allows you to view the models from the front back top bottom etc e Set the position of objects on the screen for analytical inspection of the models in relation to each other e Set the visibility of objects visualizing a part of the virtual cast which allows for a more detailed inspection of particular objects on the virtual cast e Set the objects transparency for the current operation to see or hide their internal structure e Switch to custom rotation and panning mode enabling rotation and free movement of objects on the screen
10. see the record of just the patient case specific to the model opened The function is provided in order to open a different model set for the same patient and to compare models while making a complete analysis of a single model set 1 2 Preparation Once you click Prepare model set he option you are taken to the Setup plane ba alignment I step once you get to the Preparation section Printed Documentation Set up occlusion plane Liu Please set landmark 16 Plane alignment section Following the next steps will create the virtual base on the model 1 Place the points indicating the occlusion plane following the instructions in the Plane alignment window Plane alignment cuero ro Set up saggital plane Occlusion plane Occlusion plane is set Please set saggital plane draw line on occlusion plane Indicating occlusion plane 2 Draw a red line on occlusion plane to create the Sagittal plane 24 Ortho Database Occlusion plane Drawing a Sagittal plane 3 The Sagittal plane position can be adjusted manually turns yellow 25 Printed Documentation Occlusien plane 11 21 Move the blue control point 1 to change the position of the plane along the Occlusal plane Drag the red control point 2 to change the angle of the plane Click OK to move to the next step 4 You are taken to the Virtual base step On this step you create the virtual base using such optio
11. smaller than the closer ones Show material and shadows Show as transparent Show perspective 2 3 Additional Plane Views y Click the Additional plane views button on the Visualization toolbar to open the option Select Planes configuration from the drop down menu Planes Click the Add button on the Planes window to create a new plane Give a name to the new plane place three blue arrows on the model to OS _mark the plane area Please enter name of new plane Plane name Plane 1 o ca 41 Printed Documentation The plane is annotated with its name and turns when selected Click OK to save it Direct planel plane view It is possible to select now different views according to the Reverse planel plane view Created plane ___ Planes configuration 42 3 Interactive Tools 3 Interactive Tools Interactive Tools These tools positioned on the Visualization toolbar can be activated at any step of the analysis and planning process Activation In order to avoid conflicts in user input between the open Function and the chosen tool articulator 3d measurements or 2D Cross section and to be able to toggle between them click on the tools window to activate the given tool or on the function window The active feature window is marked in blue as illustrated Yirtual articulation Occlusion 0 00 Laterotrusion 10 00 mm Y Pro fretrusian 0 00 mm E Contact mode Collide de
12. the point to open the pop up menu The linear option creates straight segments only and the control points are positioned between them The free form option resets all the segment to their original states Change to linear Change all to linear Change all to free form 2 Finish Click the Finish A button to finalize the process Select one of the four options enlisted in the section Merge with model upper lower part is available only for the bars created with the fixed on model spline Combine bar with other model Indicate the Remove undercuts retention amount parameters in the edit box for the Substract reference model option Click OK to apply the adjustments and exit the current feature step Click Apply to make the changes but remain on the current step 4 1 3 Combine Models Combine models feature allows you adding or subtracting 2 models geometries To use this option follow the next steps 1 Set the new component properties This step has the same procedure as the one for the Shell setting for more information see the Shell chapter Important the model you want to subtract from should be selected first from the list of the models 2 Combine the selected models 85 Printed Documentation Combine models Type Combine O Subtract Use the Operations tab in the left bottom corner of the Extra Combine screen to select the type of combination M Check and R
13. D Measurements and Custom Analysis i The Measurements and Custom Analysis option allows you to perform and edit the idesired 3D measurements on the model Landmarks Landmarks represent simple red points that define angles occlusion planes cross sections sections for measurements etc thus making up to all the analysis objects enabled by the system The arrow like surface markers help you navigate around the landmarks y Blue arrows define a passive selection t Yellow arrows indicate the selected objects Their positions can be changed by dragging the corresponding marker w The arrow turns when you place the cursor on it 56 3 Interactive Tools Annotate the landmark by right clicking it and selection the appropriate option from the popup menu Enter the name of the annotation and click OK i Customize the view of the landmarks by right clicking a landmark and selecting the color and form of the landmark from the drop down menu Angles are defined by three landmarks and the measurements which are immediately displayed It is possible to customize the view of the measurement by right clicking it and selecting Properties from the pop up menu You can open this pop up menu by right clicking the appropriate measurement in the Custom objects window re Planes 57 Printed Documentation oe ad Set a plane by positioning three landmarks on the model _It is po
14. Its structure allows a maximum of flexibility in the design process e The basic tools can be applied in any sequence e Any model can be exported for production i e either a modified dentition model used as master or the appliance itself Any combination of the active 3D models is supported addition or subtraction STL library items can be applied to any 3D models Predefined profiles and parameters are supported Full export and import of design template are supported to ensure productivity and consistency of designs e Virtual articulation allows appliance design optimized for the patient s specific occlusion Printed Documentation Appliance Designer Glossary e Part a part is an individual element of an appliance it consists of components and features and will typically be manufactured individually For example one appliance can be made of two separate parts one for the upper jaw and one for the lower which will be mounted together e Component a component is a building block for the appliance The 5 main component types are n mE Shell wrap surface with a fixed offset distance Bar a 3D model based gt on a 2D profile allows d to apply predefined parameters and geometries Combine models adding or subtracting 2 models geometries Remove undercuts fills undercuts to simulate e g waxing on models Load model load any STL to use it as visual guide or combine it with the appliance Features in
15. Patients TRIOS EE E Patient Selection Model set ID Status Model set Model set operator Model set comment Model set date E 2 Jane Doe 1 Prepared pre treatment 3 24 2010 E ron R 2 Prepared post treatment 3 24 2010 New model set allows you to create a new patient model set for the selected patient see the chapter New model set Edit patient options allows you to open the existing patient information form of the selected patient for editing Click Change to save changes Export to file allows you to save the selected file in the selected folder Delete patient allows you to remove the selected patient from the list The Export to file option comprises several options xport to file Allows you to export the model to the selected file Export Trios models without Allows you to export Trios models without patched areas patched areas Export to CAMBridge Exports the model to CAMBridge xport to ABO Allows you to export model formatted according to the ABO format 16 Ortho Database When you click the Export button and select the Export to file option you will open the window where you can select the folder where it will be exported to The format for the exported files is 3sz Tel As Js Je ProgramData 35hape OrthoData 2000 9 Se A e a Organize Mew folder Hza sir Favorites Date modified Type E De
16. Printed Documentation Table of Contents MOGUC CHON taa ai obs 1 Appliance Designer GIOSS A Vistas aaa 3 ORO DataSet danna 7 Pe Settna Started aii 7 Tal GOING Sta Teaser AIR 7 khit EXecutma AppllanceDesIiO ner rra A T T 7 1 Creatina a New Database Ent 8 1 1 3 Returning to the Database ENYA 12 12 Preparacion ll oleo 23 ES TRIOS isa 32 2 Appliance Designer User Interface cccooccccccccconnnnnrnrrcnn cnn rr rr rre 37 2 ApplianceDesigner User Interface cccccccccocccccnconnnn rc rr rr 37 2 Mal TODA ei 37 22 VISUAIIZATION TOCA usura INDIAS 40 23 Additional Pane VIEWS AAA 41 Ante racUve TOS ia id 43 3 INteracU Ye MOS Ne 43 Sd EFOSS SEC ON A A trwiaieene sa onee a a T ean Ate 43 342 Remove UNdercutSs aia aaa steer amas eeagun 52 3 3 3D Measurements and Custom AnNalySiS ooocccccccccnnnnnccccnccnnccna normar rar rre 56 SAAC UIO Feria 62 Sd Acuaticas 62 3 4 1 How to Adapt a Parts Design in the Articulator ooocccccccccccccccccccnnnnnnnnnnnnnn nano 70 COMPOST e elo 75 AC OM POMeMeES TaD aaa 75 Aa daa 76 AP Aid 76 A SN iia 76 A Dal S A E A E EE E E E E aa tees pane ad tan Chan E EE E A T 80 Ao A o A E ee 85 Ao Load Model ieir tarea as 88 Features Tabria orie a A AAA AAA AAA AAA AAN 93 VO ET OW WIZI d sees aca epee E ET E T A TA 99 3shape Appliance Designer 2012 User Manual Introduction Appliance Designer is a flexible program designed as a toolbox to create most of the types of orthodontic appliances
17. ab po Create Bar Click the Create Bar button The bar on the model if formed Align it using the control points Hold the right button of the mouse and pull the control point becomes when active to the desired position Use red control points to rotate the bar segments round their axis Green points allow you to squeeze stretch the bar Blue control points move the bar up down in relation to the model surface Purple control points stretch shorten the general length of the bar Double click at the blue control point cuts the bar at the control point for easy inspection 2 To undo the cutting double click the control point once again 1 83 Printed Documentation Click Adjust width to set automatically the bar width to that of the underlying model Select the type of the Bar ending from the drop down menu Flat or Wrap around In case you have selected the Fixed on model spline type mark the Use fixed on model checkbox Fit bar surface to spline if checked automatically aligns the bar to the secondary spline Press Shift to select all the control points Press Ctri to select some points only Right click the selected control point to open the popup menu With this option it is possible to Move to common plane a move all selected control points to a common _ plane Move all to common plane 84 4 Components Tab Once you place a mouse over the green segment a red control point appears Right click
18. atient when e you Create an appliance for the new patient with new model set see previous chapters Printed Documentation B e you select Open Models L button in the Main toolbar becomes active when you click Cancel in the previous case The Open models form appears Please follow the steps described below to open the existing models 1 Choose the models for the form General Select either of the 2 models to automatically locate the Open models complimentary eee ees model and open the model set loaded in three formats stl A ean Show preview Maxillary model Choose a maxillary 100000 t Decimate db models to anges model only to load into the system Maxillary model gt Maxillary model filename Preview mandil Browse Number of tangles Number of vertices gt gt Mandibular model Mandibular Mandibular model filename model Choose a mandibular model only to load into the system Number of triangles Humber of vertices 10 Ortho Database 2 Load the models to the form To browse for a model set in the Orthodontics Control Panel use the Browse buttons under each of the blank fields The default path to the folder with files of the patient database is C Program Files 3Shape OrthoData You may browse exclusively for the maxillary or mandibular models using the Maxillary model or Mandibular model fields of the wind
19. buttons 1 Click on either the upper or lower casts to visualize the green arrows 2 Click on one of the four arrows to set up the ultimate position of the cast Hold the CTRL key to rotate 31 Printed Documentation Occlusion Click the mandibular maxillary model to a Hold the CTRL key ti Modification Trans box Arrow buttons Translation step 0 10 E Rotation step 0 50 8 Collisions Collision Optimizati plimization Transition step sets up the distance for which the cast moves up Set front view and press Opti or down at one click on the arrow get optimal position of arches Rotation step sets up the degree of rotation of the model Optimiz 1 3 TRIOS Appliance Designer can work with the orders scanned with TRIOS Once you have connected Ortho System 2012 1 to Trios find more information on this in the Ortho Control panel manual you can work with the orders 32 rr wactlonts TRIOS a ejes Fatentname Clinic ID TRIOS_LN ID 2013 06 26 13 59 TRIOS LN 001 sme TRIOS_FN_001 TRIOS LN 001 Trios tab Ortho Database loja Model set Modelsetc Model set Model sets OperatorMax TRIOS ord 12 4 2012 12 4 2012 12 17 201 12 17 201 at ID 2013 06 26 13 59 TRIOS LN 001 OperatorMax ent TRIOS order comment 001 12 4 2012 e 145101 PM 1 Operation buttons indicate the actins that can be performed with the selected order
20. ct the Remove button to delete extra material or click the Smooth button The target area circle is marked blue and green respectively Adjust the Radius and Level of the marking circle by pulling the corresponding slide bars It is possible to use the already customized settings from the list of six variants Activate the desired mode by 93 Printed Documentation clicking at its number in the list To change the setting for the mode set the parameters in the Wax knife settings section and click the Save TS button Mark the Show target area checkbox to display the marking circle The Morphing A onc allows to force in and out the curve on the surface You can set the radius of the marking circle by pulling the Radius slidebar Note the green outline indicates that the model s edge will be affected by the morphing process QO The Plane cut option allows to cut the selected parts of the appliance with the plane Draw the red line by holding the left button of the mouse The cut plane is created The green arrow indicates the cutting direction You can move the cutting plane by pulling the blue control point or set the parameters in the Offset edit box You can select the already created plane by choosing it from the Default planes drop down list It is possible to adjust f the size of the cutting plane by marking the Local plane cut checkbox Set the parameters for Smooth radius in the appropriate edit box I
21. dicate the specific design parameters applied to a component Additional features which can be applied to any active 3D model ie not just to components are e Additional Features Modify model a sculpting toolkit to add remove material or smooth the model s surface Attachments allows to place an STL object from the library to the active 3D model Printed Documentation Visual model an attachment setup as visual model will be displayed on the screen but will have no impact on the underlying geometry unless one of the two following options is chosen e Additive models when this option is chosen the attachment geometry will be added to the underlying model s geometry Boolean operation OR e Subtractive models when this option is chosen the attachment geometry will be subtracted from the underlying model s geometry Boolean operation ID tags places a unique ID tag on the active 3d model to distinguish it Workflows sequence of components and features used to create an appliance or part Template a template allows to reapply a given workflow to another patient model set O O Part 1 e g upper jaw Part 2 e g lower jaw Appliance Designer Lexicon Component 1 e g Shell Shell Feature Component 2 e g Bar Component 3 fe g Combine 1 amp 2 Feature 1 pe my ee ef eee a in wt Er L L MLL ee Lak rif My fie il Ly Feature 2 q iO TL attachmenton Component 3
22. epair models oK carcel apv e Combine allows you to combine two models geometry into one new solid model Bar before Combining After Combine e Subtract will carve one model s geometry according to the other selected model 86 4 Components Tab Bar before Subtracting After Subtracting e Extra Combine allows to combine two models while carving the underlying dentition automatically 87 Printed Documentation Shell and Bar before Extra Combine Shell and Bar after Extra Combine For higher results mark the Check and Repair models checkbox Click OK to view the result of the process Click Apply to save the changes 4 1 5 Load Model a ae It is possible to load any STL model to the Components Create Shell a section Contrary to the loaded models Create Bar don t need to be fixed on another 3D model They get their own view slider which allows to view them as design guides without affecting the actual design process Click in the Part section and select Load model in the Load model popup menu The New component properties window is rr see the settings for it in the section In the Select source model section indicate the path a model is loaded from JE Create Combine models Create Remove undercuts 88 4 Components Tab a Apply color It is possible to observe the model preview Mark the Copy file to model set folder checkbox to save the copy of the model
23. ettings window e Prada ID tag ID Tags allow you to add easy identification to any output model for easy sorting in the manufacturing equipment Click at the desired area on the model It is possible adjust the ID tag in the desired position with the help of the blue and purple control points on the joystick 96 Featuresl Changes the angle of ID tag 1 position according the surface Moves the ID You can setad 2 along the surface of appliance 3 Rotates the ID tag round its axis You can customize the look of the Id tag in the ID Tag generation window Type the ID Text and select the drop down menu Detachable or Integrated Indicate the Text Depth and Font Height in the appropriate edit boxes for Integrated ID Tag type Place one control point in the desired area to indicate the detachable ID tag and click OK to view the result 97 Printed Documentation Set Connectors count and Min distance to Model in the corresponding edit boxes for Detachable ID Tag type 98 6 Workflow Wizard Components Features Workfiows Workflows navigation The Workflow wizard section presents the list of actions performed to create the selected part Ce It is possible to navigate the list by using the de or b Bar Mani buttons Click the arrow buttons in the upper right corner of each ae m section to fold unfold it af oeta maie You can select any step from the list and modify it using its speci
24. f marked the Show cut off part shows the section that was cut To select another side of the plane cut click Swap cut direction Click Clear to delete the plane cut The Spline cut option allows to cut off the parts of the appliance using the splines Mark the desired area with the splines It will be circled with green line and the rest of the model will be transparent It is possible to Save parameters for this option or Load the already existing on another model Select the Spline type Set the Fillet radius and Plane offset parameters in the corresponding edit boxes Use the Reverse Direction button to change swap the selected area Mark Additional plane cut checkbox to create the additional plane 94 0 63 mm e a A Spline cut Undo all 1 Fp Y Show bands Y Show legend Featuresl Use the Global transformations gt option to stretch squeeze the appliance to the desired length and height Use the green and red control point to move the appliance Hold the left button of the mouse and pull the control point in the desired direction You see the ruler to view the numerical information on the movements you perform It is possible to rotate the appliance by pulling the red control point Click OK to apply the changes R You can Undo Redo the operation by clicking the appropriate buttons It is possible to view the history of actions performed by clicking the black
25. fic settings displayed in the left bottom corner 4 Modify model 99
26. hange the angle 3 of the articulator position Use the visibility slider Es in the upper right corner of the screen to customize the view of the articulator 3 Use articulator to evaluate and adapt design 66 3 Interactive Tools Yirtual articulation Fy A Click the Li on the Virtual articulator window to open the settings tab Occlusion 0 00 To set Occlusion Laterotrusion and Pro retrusion you can Laterotrusion 0 00 e Edit the parameters in the appropriate edit boxes in the Virtual articulation window O GO e Move the jaws by holding the left button on the mouse e the red control point appears and the parameters are _ Collide designs a updated automatically Record contacts E Pro fretrusion 0 00 mm E free the movement of the required plane Place the cursor over the articulator model and drag it while keeping the mouse button 67 Printed Documentation With the Upper Lower jaw button you can select the jaw you want to move with F when resetting 9 the articulator to the static occlusion Click to lock the modelling position of the articulator To set the articulator in modelling position click E There are three options in the Articulate function e Contact mode on off auto shut AS indicates the position of jaws in relation to their penetration e Collide designs indicates in color the collisions of the jaws The Occlusal compass te button allows to colo
27. ill need to click the Browse button and select your placement file to use The Set as default button saves you current auto placement method to use as the default one for future l orders se Auto placement options EA A The Perform placement button initiates the T Use guide plane auto placements Articulator specific for use with adapter plates process with the chosen options Analyze scans is a selected for the models without Setas default Perform placement Close Adaptor plates You can load predefined planes created in e g OrthoAnalyze r such as the occlusion plane as default position in the articulator by checking the User Guide plane box and selecting the plane from Auto placement method Analyze scans for use without adapter plates Default 5 Use custom placement 64 3 Interactive Tools the drop down list Use custom placement is used when the adaptor plates are included Click the Browse button to set the Placement file path The placement can be adjusted manually by moving the blue plane The plane can be moved up down and rotated with the cursor by the indicated points to find the correct position It is also possible to translate the plane by dragging it You can change the tilt of the plane by dragging its rim 65 Printed Documentation Moves the 1 articulator up and down Rotates the articulator C
28. lar bases ot Neer of the base and the baseless model Allow splines If checked lets the splines be placed outside the out of bounds fit base box 29 Printed Documentation e Create base Once adjustments to the bounding box at the Fit base step are complete click the Next or Create base button to create the virtual base Click OK to close the Virtual base dialog window Your models now appear to have virtual bases The image below shows the virtual base using the included Arch Max and Arch Man bases STL models 5 Sculpt Maxillary Mandibular option is open automatically Here you can trim the results of the previous steps Find more information on Sculpt tools in the Features section 6 Click Finish to end the procedure and save the prepared model You are automatically taken to the Open patient case section Y Occlusion step helps to align the upper and the lower virtual casts 30 Ortho Database Trans box 1 Click on either the upper or lower casts to visualize the corresponding bounding box 2 Drag the purple control points on the ends of the axis arrows turn yellow to set up the ultimate position of the cast Modification Collisions Collision Optimization Set front view and press Opt get optimal position of arches Enter the necessary values for the Maxillary distance and Optimize Mandibular distance to move the upper and the lower casts up and down Arrow
29. llows you to be immediately taken to the Features tab for the selected component Click OK to save the settings Add Attachments Alternatively you can right click at the Add ID Tag desired model and open the drop down menu duplicating the options in the Part tab Create Shell N Create Bar Create Remove undercuts 2 Define a shell on a model You need to indicate the area of the shell on the model Place the control points to create a spline that will define the shell Add point Double click the first control point on the spline to close it It is possible to edit the spline by right clicking at it and selecting the appropriate options Clear spline from the pop up menu Remove point Fast edit spline 78 4 Components Tab From the Shell features it is possible to set the parameters of the Shell in the Settings window Thickness edit box displays the thickness parameters of the shell Remove undercuts if checked removes all the undercuts visible from the set insertion direction to ensure easy insertion of the shell on the underlying model 2D Cross section D Cross section Settings Thickness 1 4mm Remove undercuts Retention amount Omm F Use offset for inside surfar Heel 0 01m Use edges smoothing Smooth factor 0 75 without Remove undercuts with Remove undercuts Reverse spline selected p Retention amount allows you to define a retention factor that will compe
30. n from the Create Combine modek drop down list see the image to the left Create Combine models Create Shell D STA Create Remove undercuts Load model 76 4 Components Tab Indicate the Name of the shell New component properties E Name Image he name of tne e vi Text component vr Apply color corresponds Select source models to the name Color for model of the None Output None It is possible to select source models on which Start now dl the component is to be built OK by pressing the Click Come _ button The All available 4models window pop ups see the image below All available models Note Appliance Designer allows you to build any component on either the tooth model or on any other component created previously Select the model from the list or click Set empty to leave the source model unidentified Fill in the Text that will be displayed on the Shell icon to ST aE the left The last sign in the Shel gt Wtext 2 Name section will be an IF Apply color duplicated in the Text section see the image to the left Apply color if checked allows you to apply the selected color to the image icon 27 Printed Documentation Customize the color of the model click the colored square and select the desired color from the palette To get back to the default color click the Reset to default button Start now if checked a
31. ne Allows you to save the h current plane la View Removes cross section Measure area Allows you to measure distance on the model in the 2D Cross section window E Clear measure Deletes the measures Zoom all Allows you to zoom the model Note You can reuse and apply any custom plane created and saved in OrthoAnalyzer in Appliance Designer by choosing them from the list of Standard planes Once you have selected the Save plane option you get the popup window Choose the Save as new plane option and confirm the action by giving the Name to the new plane and clicking Save 46 3 Interactive Tools You can select any saved plane in Standard planes section Step 2 Move the cross section plane 1 The control point located on the plane corner rotates the plane clockwise and anti clockwise without moving it or changing its slope Thereby you can select the most appropriate position of the plane for making on grid measurements 2 4 Change the slope of the plane along the perpendicular cross section plane which is perpendicular to it To visualize this additional plane activate the blue circle by clicking on it to make it turn yellow When the cursor is positioned on the yellow circle with its own red control point indicating the movement path is displayed While pressing the mouse button drag the control point to change the Slope of the cross section plane 3
32. ns as Define cut Fit Base and Create Base e Define cut 26 Ortho Database Virtual Base Teeth models Select base model Full upper base 1 Step 1 3 Define cut E Fast edit spline Lower Fast edit spline Improved bases auto sizing Define cut option Use the following options to operate through the step Upper Lower base icons toggle the visualization of the corresponding models for better overview Previous Next operations navigation buttons Define cut used to draw the cut br Fit base adjusts the base ee Create base creates a new base Fast edit If checked allows you to place the spline by drawing spline it on the surface instead of placing control points Clear Removes the incorrect splines splines Improved If checked allows to fit the model automatically the bases virtual base auto sizing Decide on the part of the model you wish to leave click the Define cut button if not already at this step and place the spline points over the model curve to define the cut Click the first point of the spline to close it Adjust the spline manually by dragging the points with the cursor to the required position 27 Printed Documentation Add point Remove point Clear spline Fast edit spline Editing spline From the right click menu options of the cursor positioned over the cutting spline you can Add new or Remove indicated spline points Clear spline or use Fas
33. nsate for the removed undercut depending on the material to be used for manufacturing If it is O then all the undercuts are removed The larger the parameter the more retention is provided ok Cancel for in spite of the undercut removal Use offset for inside surface indicates the parameters of the offset inside the shell Offset Allows you to set the offset parameters in the edit box Use edges smoothing If checked sets smoothing for the edges of the shell Smooth factor Allows to indicate the parameters for smoothing in the edit box as a factor of the shell thickness Reverse spline selected part Reverses the splines placement that the opposite area that originally selected will be shelled Click the View insertion direction button to observe the insertion direction indicated with the blue arrow The Set direction window appears 79 Printed Documentation Save as default Show colors Show colors if checked displays the undercuts marked by different colors according to the color scheme in the right bottom This option is generally used for the Remove undercuts step Click Apply to change the insertion direction according to the view on screen 4 1 2 Bar A Bar is a 3D model based on a 2D profile that allows to apply predefined parameters and geometries Note to be able to use Bar component you need to define some 2D profiles of bars in the Ortho Control Panel see the Ortho Co
34. nspection and imports them into the system Fa Save session Saves the current analysis session to default file LA export models as Saves the current analysis session to the selected file Once you have selected the Export models as button the Export models window appears displaying all the models and components select all Select the path for the saved models and click OK It is possible to customize the general application settings Go to Application gt Preferences The Preferences window appears 38 2 Appliance Designer User Interface Preferences m The Preferences window posses three tabs Visualiza In the Feature tree set the parameters for the Features tab in Visualization settings the ApplianceDesigner Anti aliasing Language tab allows you to select Flat shading the language of the program from Material shaders the drop down menu Draw shadows Visualization tab offers a choice of checkboxes to customize the view of the model in the program Click OK to save the settings Patient model set The Models button opens the list of options that duplicate the La functions in the Main toolbar Save session Export models as Auto collapse groups The View button allows you to customize the look of the Components tab Information panel wv View tools Large buttons for components It is possible to operate with templates in the program Click the button to
35. ntrol Panel manual for more information To create a Bar you need follow the procedure 1 Define the new component properties This step is identical to the one from the Shell setting 2 Set a bar on the model a Set the insertion direction 80 4 Components Tab Indicate the insertion direction 2 in the Set insertion direction window 1 and mark the Show colors checkbox to observe the undercuts The Undercut depth color scheme will be displayed in the right corner 3 2 Define spline Click the Define spline i button to move to the next step or click a 1 Central spline tab There are two ways of placing the spline 3D spline on models 81 Printed Documentation Place the spline in the desired area by simply clicking at the surface of the model Click Next to continue 2D spline on models To place the central spline in 2D mode select the plane from the Plane drop down menu you have to create the desired planes before this For more information see the Additional Plane Views section Adjust the plane in the Offset edit box Place the spline of the plane and click Next To redo the spline click Clear spline Otherwise right click the spline to edit it Add point Remove point Clear spline Ls 2 Fixed on model spline This option allows to create a secondary spline to limit the lower part of the bar Click Next to move to the following step 82 4 Components T
36. ow If both parts of a model set are required then it is possible to either select them using the option described above or to browse for any of the two models in the General field The system automatically locates the pair model in the same folder to form a properly occluded double cast for further inspection Open models General de LA Program ata 35 hape DrthoData 2011 1 BET4 200172001 1 F Show preview Decimate db models to 100000 triangles Maxillary model Maxillary model filename LA ProgrambD atas dS hape DrthoDiata 2011 1 BE TAS20015152001_1_F Browse Number of triangles 170204 Number of vertices 85104 Mandibular model Mandibular model filename L ProgramD atas 35 hape DrthoData 2011 1 BETAZO014 12001 1_ Number of trarngles 191604 Number of vertices 75804 3 Check Show preview to see the selections made in the preview boxes to the right of the window 4 Check Decimate db models to triangles to decrease the number of triangles on the model to a predefined value 11 Printed Documentation 5 Click Rotate to set the appropriate rotation angle for the relational positioning of the maxillary and the mandibular models In the new window which pops up immediately after you push the Rotate button move the Rotation degrees sliding bar minimal value being 180 maximal 180 to bring the rotation angle to the necessary value View the changes made in the preview boxes provided to help you to control
37. parameters for the Cut contacts in the appropriate editbox 1 and click the activated now Adapt design button to finish the process 2 73 Printed Documentation 74 4 Components Tab 4 Components Tab Components are the main building blocks used to create an appliance part The main Components are Shell Bar Combine models Remove undercuts and Load model The Components tab la eps presents the section where it is possible to operate with the Create new part appliances for the model It is possible to observe the relation between the two jaws by using the color scheme Select both jaws and right click the model Select the Distance map button o E Workflows 75 Printed Documentation Parts are the main elements of an appliance Using parts allows for more overview in the design process and to create a file that will be exported _ individually For example for an appliance that consists of a maxillary and l mandibular element two parts will be created individually Components Features Workfloy Click the Create new part y button give a name to the part and click OK A Shell is a wrap surface with a fixed offset distance To create a Shell you need to proceed with the following steps 1 Set the new component properties Partl A A f In the newly created part section click the button in the Create Bar Part section and select the Create shell optio
38. possible to select the Revert angle or edit the angle parameters a 1 manually aa Distance to measurement requires one point on the desired measurement and one point on the grid H Spline measurement allows you to measure curved areas with the help of the spline 49 Printed Documentation z Distance along centre line requires two points Measures the distance in relation Fo to the centre line Symmetry points requires one point Automatically places the second point symmetrically to the selected one along the center line 50 3 Interactive Tools The 2D cross section allows to take measurements automatically at the intersection of the chosen plane and 3D model in screen All measuring points snap to the intersection It also allows to take measures of area and perimeter defined by this cross section The measurements placed on the model in the 2D cross section window are automatically mirrored on the model in 3D 51 Printed Documentation 18 09 mim SS rit 294 2 148 2 mm 1 2 The points placed on the cross section are automatically attached to the beige contour of the cross section 3 The system automatically builds the right angled triangle using the selected measurement line as its lateral face 4 The measurements of the other faces of this triangle are also displayed on the cross section ua e To clear the measurements made click the button Click
39. r Appliance date Test ID Test Appliance4 Applance4 gt herbst template 1 3 14 2012 It is possible to select the template from the drop down menu All the templates imported to the programme will be displayed here Enter the Appliance id and the name and click Create to proceed H 2 ID sghrsg m 3 Jane Doe E After creating the new appliance you can observe it in the Open patient form list Right click the Appliance con select Modify appliance info 4 button from the popup menu to edit the appliance information or Delete Appliance button to remove the appliance All of the options described above may also be accessed by right clicking on the active selection label top or image bottom 21 Printed Documentation Edit model set Prepare model set Delete model set New patient New Appliance Refresh previews 3 24 2010 3 24 2010 233 16 PM 2000 2 post treatment The Preview option displays the preview of the selected model Once you click at this option the Order 3D Preview form appears 22 Ortho Database lt Order 3D Preview Form Order 3D Preview form 1 1 3 2 Open Model Set In order to complete this step it is required that there is a patient case created see the chapter New Patient Having opened a patient model set in the session window see the chapter Patient Model Set you can use the Open model set option to
40. r the areas of collision according the color map 2 68 3 Interactive Tools PT Protruston Laterotrusion The legend of the compass Disabled it colors the areas in blue 1 e Record contacts if checked enables the Adapt design section Indicate the Min distance and Adaption radius by setting the parameters in the appropriate edit boxes The operation can be undone with the Undo button 4 Simulate articulation It is possible to imitate the articulation motions by clicking the Wbutton to start the articulation Click D pause the process or 0 stop it To repeat the process click e Click the button to customize the motion sequence 69 Printed Documentation Edit motion sequence LZ Sequence view Begin Laterotrusion round trip Pro retrusion round trip Motion view Occlusion no effect if auto shut is active Laterotrusion Pro retrusion min Pro retrusion max List of sequences Edit buttons Operation buttons Motion 4 view section The List of sequences can be customized with the Operation buttons Add new sequence Move up down the list or Delete from the list 3 4 1 How to Adapt a Parts Design in the Articulator After creating the Appliance it is possible to adapt its design with the help of the Articulator Please follow these steps 1 Open the component you want to adapt Click the Feature tab and select the component you want to wo
41. rk with 70 3 Interactive Tools Current workflow wizard Al EA Grcclusion 2 23 mm Y Laterotrusion 2 64 mm Y Pro retrusion 6 60 mm 16 Contact mode fas Collide designs Record contacts a Adapt designs uk contacts 0 01 mm 2 50 mm M 34 9 gt Adaption radius Shell designer Settings Lak 1 Thickness imm Remove undercuts Retention amount Use offset for inside surface Offset 0 0imm Smooth factor 0 75 Ss Reverse spline selected part e 2 Activate the Modify Model option Select the Modify model option to open the Sculpt 71 Printed Documentation Components Features Workflows FA vu Occlusion o l mm y Laterotrusion 2 64 mm Y Pro fretrusion 6 60 mm 16 Contact mode AS Collide designs Record contacts ce E NO Sculpt toolkit Cut contacts 0 01 mm u7 daption radius E 50 mm Wax knife settings A C HY 90 0 pm SHI Show target area F at wg 1 20 mm a m i Note The active Sculpt option is a must for the further process 3 Articulate Activate the Collide designs and the Occlusial compass to view the problem areas Move the jaws in the articulator by holding the pressed left mouse button and changing the position of the red control point 72 3 Interactive Tools Occlusion 0 34 mm Y Laterotrusion 0 00 mm pa Pro retrusion 3 60 mm e 4 Adapt the appliance Enter the desired
42. shes visualization of the settings changed in the Ortho Control Panel AX Delete model set button removes the selected model set from the list at If the model is not prepared it will be marked with the red exclamation y mark Double clicking at it will automatically open the Preparation step Note There are two preview options available at this stage small previews and large previews The size of the large preview images can be set in the Ortho Control Panel Click on the Views button on the top toolbar to select the most convenient viewing option 19 Printed Documentation 3 Export to file A Import from file ay Export to CAMBridge 49 Delete model set 2 35 16 PM post treatment 3 24 2010 3 24 2010 Throughout advancing to the last node of the selection tree the system assists you in tracing the order selection as well as in managing the active selection with available options There are two sections in the window which perform this task e The dark grey field at the bottom of the window summarizes the information related to the active selection e The top toolbar window modifies its content according to the active selection When you click the New Appliance button the dialogue window appears 20 r New Appliance Ortho Database Appliance information Patient id Model set id Appliance id Appliance name Template name Comment Operato
43. signs Record contacts gt Adapt designs ko Min distance mm Adaption radius 2 50 rm 3 1 Cross section The Cross section button in the Visualization toolbar opens the 2D Cross section wv preview in the bottom right corner It can be accessed at any time during the modeling process to inspect the design 43 Printed Documentation 0 0 Dl ALA SERED Eee ee eee ER ERE RR E eee 0 0 0 0 EE s e i _ oy 7m 1 Measuring buttons 2 Cross section plane 2D Cross section 3 Temporary plane window 44 3 Interactive Tools liz Step 1 Draw the Cross sectio n plane Draw the red line to define the cross sectio n It is also possibl e to define a cross sectio n plane by placin g three 45 Printed Documentation points Use the manipulation buttons on the 2D Cross section Temporary plane window 2 View buttons unfold the number of options that customize the view of the cross section plane Clipping plane Left Hides the right side of the model in relation to the cross section plane Clipping plane Right Hides the left side of the model in relation to the cross section plane Fixed camera allows to fix the plane in one position and move the model instead Grid turns on off the grid of the cross section plane Standard planes Allows you to select Md the plane through which the cross section plane will go 4 Save pla
44. sktop gt 11 2013 5 36 PM File folder mM Downloads 6 26 2013 5 12 PM File folder Recent Places MI Desktop Libraries Es Documents a Music Pictures E Videos File name MI EIA AA IEA Apt Save as type Ortho System import files 35z Hide Folders Exporting to file i y When you select the Export to CAMbridge option from the list the button turns to you can observe the preview of the selected model in the Model preview window 17 Printed Documentation Model preview window Cc WU Unfolding the patient model set tree further and clicking on one of the model IDs e g 2 representing the selected model set will display seven views corresponding to this particular model 18 Ortho Database Open patient case l gt BE x Patients TRIOS TRIOS A Patient Selection st date 12 17 2012 8 50 46 AM scan date 12 17 2012 an time 8 50 46 AM Open model set button produces just the same effect as a double left click on the selected model e it submits the selected model to the analysis process opening it in the session window Edit model set button opens the existing patient case information form and suggests editing the fields which were previously filled in Click Change to save changes a model set allows you to create the virtual base on the model da new Appliance button allows you to create appliance for the selected patient case Refresh previews option refre
45. ssible to customize the iN plane by right clicking its name in the Custom objects an Y window Planel Open Planel in Cross se Annotate Delete Properties Measures Place two landmarks on the surface of the model to make the measurement It is possible to edit it by right clicking the measurement line if place a cursor on it turns __ if selected turns 58 3 Interactive Tools Place two landmarks on the surface of the model to make the measurement It is possible to edit it by right clicking the measurement line if place a cursor on it turns __ if selected turns You can select the Measure type from the drop down menu after right clicking the measurement and select Properties 11 44 Indicate the measurement by two landmarks replicating a physical calliper Customize the measurement by right clicking the landmark and opening the popup menu Distance to line 59 Printed Documentation a J ae a mA 7 i 4 a eer F oni a ae es es ss nm Ls n 7 A Distance to plane To make this measurement create the line gt place the landmark at the area you want to make the measurement from gt click at the selected line To measure the distance to plane create a plane gt place a landmark on the area you want to measure the distance from gt click the green border of the plane or the annotation if there iS i Cus
46. t edit function to correct the spline Please refer to the Ortho Control Panel manual chapter Construction Elements to learn how to add these models to the list Select the arch_man arch_max base models from the drop down menu in the Select base model section e amp 4 Fit base 28 Ortho Database Once maxilla and mandible splines have been placed click the Next or the Fit base buttons to go to the Fit base step You can adjust orientation of the base by dragging the violet points and the base size with the green points of the bounding box Click and hold the mouse button to drag the bounding box to the required position Virtual Base Teeth models Select base model Full upper base 1 Full upper base 1 Step 2 3 Fit base Show Virtual Base Scale s trically Curvature Decimate base to Dist between bases n 7 Allow splines out of bounds offset om y Splines T Upper fast edit spline Lower fast edit spline Show cut off parts of models Fit base The following parameters of the base can be modified salud virtual Toggles visualization of the virtual base Scale Sets whether the bounding box is scaled Symmetrically symmetrically when dragging by the green points Specifies the decimation amount of the base Decimate base to triangles see image below Sets the amount of curvedness for the base model along the sides see image below bases the mandibu
47. t external id SaN o Comment First mame l Operator Last name l Status Address Model set date City Scan date Country Clinic The system has several indications in the main window to help you look for the necessary model sets in the catalogue 13 Printed Documentation a a Clicking on the root of the Patient Selection tree will display patients IDs and names E Open patient case Patients TRIOS Patient Selection The options available at this stage are e patient creates a new patient in the patient database see l the chapter New patient Import from file button permits to import models from other A folders Selecting the Import from file button opens the Import window where you can select the folder the file will be imported from The format for imported files is 3sz 14 Ortho Database Open GG Search 2001 Al Organize Mew folder e Favorites Date modified Type BE Desktop 2 21 2012 248 PM File folder iy Downloads E Recent Places Libraries Documents a Music Pictures a Videos Ma Computer EL Local Disk C Ga Local Disk D File name Importing from file b a Clicking on one of the patient ID name in the catalogue will display the ID operators comments model set dates and scan dates associated with all the model sets for the patient ID selected 15 Printed Documentation Open patient case
48. the Measure Area PA button and place the cursor over the area you want to measure The area becomes colored yellow and its value is calculated automatically Note that the second value is the perimeter of the cross section It is possible to open this function on any stage of your modelling process 3 2 Remove Undercuts Remove undercuts fills undercuts to simulate e g waxing on models To set the Remove undercuts option follow these steps 1 Set the remove undercuts properties 52 3 Interactive Tools F Create Shell Y Create Bar In the newly created part section click the button in the 0 A a Part section and select the Create Remove undercuts W1 Create Combine models option from the drop down list see the image to the left Lo Create Remove undercuts N Load model Indicate the Name of the new component New component properties ES a Important the name e of the Removelnderavts test ds Text t component A r corresponds lv Apply color to the name Select source models of the Color for model Output Click None model 0 It is possible to select 4 Start now source models on which the 0 component is to be built by aes pressing the Click button The All available models window pop ups see the image below 53 Printed Documentation Select the model from the list or click Set empty to leave the source model unidentified Fill in
49. the Text that will be displayed on the Remove undercuts icon to the left The Wrex 2 last sign in the Name section Apply color will be duplicated in the Text section see the image to the left Apply color if checked allows you to apply the selected color to the image 2 Remove undercuts e set the insertion direction 54 3 Interactive Tools Once you get to the Features tab you can customize the parameters for removing undercuts in the Set insertion direction window 1 Save as default if checked allows to set the selected insertion direction as default Show colors indicates the areas on the model according to the Undercut depth color scheme 3 You can observe the areas that will be removed on the model 2 Reset to default allows you to undo the adjustment of the insertion direction back to the default one Set insertion direction For component RemoveUndercuts 2 Save as default Nee colors e remove undercuts tas It is possible to indicate Retention amount in the appropriate edit box on both steps The Cut the model with plane button is activated on this Cut the model with plane step Adjust the position of the cutting plane by dragging it A and click the button It is possible to undo the cutting by clicking the Restore button Retenton amount 0 1mm 55 Printed Documentation Click OK to apply changes Click Apply to save the results 3 3 3
50. the brush tool to paint the model reference surface while keeping the left mouse button pressed Click Apply to perform the changes but remain on the current step Click OK to apply the alignment and exit the current option 91 5 Features Tab Components Featuren Workflows The Features are the parameters of components as sm described in this section But there are also additional features that can be applied to an existing component It is automatically open if you have marked the Start now checkbox while creating the new component It is possible to use the Current workflow wizard operation buttons to customize your steps The Previous button allows you to undo the changes ar Next button allows you to move to the next step yt Done button finalizes the customization process The Add Feature button opens the c drop down menu with additional features oy Add modify model The modify model is a sculpting toolbox that allows you to make local changes to the selected component or model s geometry This option adds the Modify model step to the selected component or model This is applicable when you have created a certain appliance and need to trim it The Sculpt window is open The Wax knife LY option allows you to add or remove surface on the selected area Click the Add button in the Wax knife settings section to add some material to the scan The target area circle is marked red Sele
51. the maxillary mandibular and the occluded modes rotation 6 Click Load to display the selected model s in the session window and start the analysis session 1 1 3 Returning to the Database Entry 1 1 3 1 Patient Model Set P The Patient model set option allows you to start the analysis session You can also start analysis session by opening an existing patient model set by clicking the Patient model set button in the Main toolbar Then the empty Open patient case window pops up suggesting to search for a patient IN Patients TRIOS FAA Search in all fields Search patient name Search patient ID Search patient 55N Search patient address Search clinic ID Search comment Match whole text Open patient case window 12 Ortho Database You can use two options to search the cases in the system Search Use the Search bar in the right corner of the window to view model sets for inspection Click the blue triangle in the corner of the field to apply different criteria for search Click the Search button leaving the Search field blank to see all available model sets configured in the Control panel A list of patients sorted by their IDs will appear under Patient Selection which would offer model set s for further inspection Advanced search Use the Advanced search option for more precise results Patient information Model set information Patient id Model set id Patient external id Model se
52. tom spline 60 Ly To create new distance set ist landmark Measures v Measure undefined Measured EE 4 Planes Saggital plane OrthoAnaly Horizontal plane OrthoAna Anterior posterior plane 0 Cross section Plane 1 Ort Cross section Plane 2 Distances Distancel 5 13 4 Custom splines Custom sorinel undefined 3 Interactive Tools To make this measurement place a few control points that define the spline Double click the last control point to close the spline To hide the measurement click the green tick in front of the measurement plane The selected object is highlighted To fold unfold the groups click the 4 arrow in front of its name 61 Printed Documentation 3 4 Articulator 3 4 Articulator mn The Articulator option is activated with the Articulator button in the Visualization toolbar during the design process 1 Modify the arman of the jaws You can set the jaws in the desired positions by clicking the ocr ll button in the Virtual Articulation window and Virtual articulation moving the control points with the cursor for a better fit see the images below Occlusal change The indicated value of displacement in the occlusion direction is relative to the original static occlusal and Shown in millimeters It can be set directly by clicking the value and keying in the number directly or selecting it with the buttons next to the value Use the but
53. tons in the Virtual articulation window to undo your changes to the static occlusion 1 or update the static occlusion with the current alignment of the jaws when you are satisfied with the results 2 Occlusal change Optimize ocdusion Click the Optimize occlusion button to align jaws automatically The red control point allows to rotate the jaw The blue control point allows you to move the jaw up and down Set the alignment of the jaws 62 3 Interactive Tools y 2 Setup articulator model and adjust placement Click the button on the Virtual articulator window to start the setup Select the type of the articulator from the drop down menu clicking the arrow button It is possible to place the model in the articulator according to the Occlusion plane selected from the popup menu Set up the desired plan first in the Additional plane views section ACR Cartes compatible Bennett L 10 00 articulator model parameters they can be set by clicking the appropriate editboxes and entering their parameters manually or Bennett R 10 00 selecting them with the buttons next to the values L Bennett R Bennett L cond incl R cond incl are Ca a Inch L 34 00 The Auto placement 1 button allows you to customize the Cond incl A 34 00 default placement method and perform auto placement of the model Click it to open the Auto placement options window 63 Printed Documentation You w

Download Pdf Manuals

image

Related Search

Related Contents

mcd digital scroll system - Repuestos Clima Spare Parts Saunier  Manual de usuario del Panel de Parcheo UTP CAT 6 con 24 puertos  Power Delivery Network (PDN) Tool User Guide  Sony CDX-GT616U User's Manual  Philips CMS Patient Monitoring System  Hampton Bay 21709-012 Instructions / Assembly  Jøtul I 150 FL - Kominki norweskie  Inhaltsverzeichnis  