Smoke Alarm User`s Manual IMPORTANT SAFETY INFORMATION
Contents
1. plate by turning counterclockwise at the back of the smoke alarm To later engage tamper resist feature twist out and set aside one of the pins moulded into plate Both pins are exactly the same 2 Install the mounting plate to ceiling or wall with mounting screws UJ Pull the plastic tab at the back of the smoke alarm to activate the battery 4 Position the smoke alarm into the mounting plate and turn clockwise to lock into place To engage tamper resist feature insert the pin into notch on edge of the smoke alarm after the alarm is properly positioned in the base 5 Push test button to test smoke alarm See section TESTING THE SMOKE ALARM OPERATING YOUR SMOKE ALARM Once the smoke alarm has been installed A RED indicator light LED should flash approximately once a minute to indicate the battery is healthy and the unit is operating properly If smoke is detected the unit will emit a loud pulsating alarm and a RED indicator light LED will be flashing quickly until the air is clear The HUSH feature can mute the detector if it has been inadvertently triggered by holding down the TEST HUSH button for a few seconds The smoke alarmwill be muted 10 minutes and then reset into normal mode after this period NOTE If the smoke density increases during this time the smoke alarm will be triggered into alarm again TESTING THE SMOKE ALARM 1 Test each smoke alarm to be sure it is installed correctl
2. the device away from the source of the fumes If for some reason the alarm continues to sound without smoke or heat being present due to insect infestation or contamination build up for example the unit can be silenced by disconnecting power and removing the unit for cleaning See CLEANING HUSH FEATURE This smoke alarm has a combined Test Hush button to help you control nuisance false alarms 1 To cancel a false alarm press the Test Hush button located on the cover The alarm will automatically switch to a reduced sensitivity condition very large levels of smoke from a nearby fire will override the Hush on the smoke alarms This condition allows unwanted alarms to be silenced for a period of approximately 10 minutes The unit will flash the red light every 10 seconds instead of the normal 40 seconds to indicate the sensitivity is reduced On interconnected alarms pressing the Test Hush button on the one sensing smoke i e the one with the red light flashing every second will silence all alarms Pressing the Hush Button on any other alarm will not cancel the alarm 2 The unit will reset to normal sensitivity at the end of the silenced period If additional silenced time is required simply push the Test Hush button again MAINTENANCE AND CLEANING In addition to weekly testing this smoke alarm requires periodic cleaning to remove dust dirt and debris BATTERY REPLACEMENT Battery replacement is not requi
3. Family First PHOTOELECTRIC SMOKE ALARM MODEL FFP9VH 102 Smoke Alarm User s Manual Please read and save this manual Photoelectric smoke alarms are generally more effective ke at detecting slow burning fires m m ke which smoulder for hours before bursting into flame eg cigarettes burning in couches P E E or bedding MAIN FEATURES DC operated photoelectric type smoke alarm Photoelectric sensor for slow smouldering fires 9V Lithium 10 year sealed battery Self Test button Hush feature Insect proof enclosure Environmentally friendly non radioactive technology High and stable sensitivity Quick fix mounting bracket for easy installation Fitting and battery tamper resist feature LED operation indicator Extra loud alarm sound over 85 dB Low battery and battery missing warning indicator VV VV VV VV VV VV VV Auto reset when smoke clears SPECIFICATIONS Model Number FFP9VH10Y2 Detection Type Photoelectric Chamber Power Source 9V DC Lithium Battery Standby Current 15uA max Alarm Current 30mA max 85 Decibels at 3 meters 5 C to 45 C 10 90 3 0 6 0 Obs m 110mm diameter Alarm Sound Level Operation Temperature Ambient Humidity Sensitivity to Smoke VV VV VV VV VV Compact size IMPORTANT SAFETY INFORMATION 1 This smoke alarm requires constant working 9 volt battery to operate properly This smoke alarm WILL NOT work if DC power is not connected or has failed or been interrupted for any
4. ke alarms may not alert every household member every time The alarm sound is loud in order to alert individuals to a potential danger However there may be limiting circumstances where a household member may not hear the alarm i e outdoor or indoor noise sound sleepers drug or alcohol usage hard of hearing etc If you suspect that this smoke alarm may not alert household members install and maintain specialty smoke alarms Household members must hear the alarm s warning sound and respond to quickly reduce the risk of damage injury or death that may result from fire If a household member is hearing impaired install special smoke alarms with lights or vibrating devices to alert occupants 8 Smoke alarms can only sound their alarms when they detect smoke Smoke alarms detect combustion particles in the air They do not sense heat flame or gas This smoke alarm is designed to give audible warning of a developing fire However many fires are fast burning explosive or intentional Others are caused by carelessness or safety hazards Smoke may not reach the smoke alarm QUICKLY ENOUGH to ensure safe escape 9 Smoke alarms have limitations This smoke alarm is not foolproof and is not warranted to protect lives or property from fire Smoke alarms are not a substitute for insurance Homeowners and renters should insure their lives and property In addition it is possible for the smoke alarm to fail at any time For this reaso
5. ll the home 3 Install a smoke alarmin each room that is divided by a partial wall 4 Install a smoke alarm in lived in attics or attics which house electrical equipment like furnaces air conditioners or heaters gt 300mm Heat and gt Besthere A S smoke F from fire p gt Dead air space Do Not install here b Dead air space 900mm min Do Not install here gt DO NOT INSTALL SMOKE ALARMS NEAR 1 Areas near appliances or where normal combustion regularly occurs near furnaces hot water heaters Use a specialised smoke alarm with unwanted alarm control for these areas 2 Areas with high humidity like bathrooms near dishwashers or washing machines Install at least 3 metres 10 Feet away from these areas 3 Air returns or heating and cooling supply vents Install at least 900mm 3 Feet away from these areas The air could blow smoke away from the detector interrupting its alarm 4 Rooms where temperatures may fall below 5 C or rise above 45 C 5 Extremely dusty dirty or insect infested areas where loose particles interfere with smoke alarm operation WARNING Incorrect orientation will result in a decrease in operational effectiveness HOW TO INSTALL THIS SMOKE ALARM h hareng Sits j irera Ea WARNING Smoke alarm installation must be in accordance with the requirements of the national electrical code and any local codes that may apply 1 Remove the mounting
6. mbers outside the building WHAT TO DO IN CASE OF FIRE Do not panic stay calm Leave the building as quickly as possible Touch doors to feel if they are hot before opening them Use an alternate exit if necessary Crawl along the floor and do not stop to collect anything N RB 3 Meet at a pre arranged meeting place outside the building 4 Call the fire department from outside the building 5 Do not go back inside a burning building Wait for the fire department to arrive These guidelines will assist you in the event of a fire However to reduce the chance that fires will start practice fire safety rules and prevent hazardous situations TEN YEAR LIMITED WARRANTY Master Distributors Pty Ltd warrants to the original consumer purchaser that each new smoke alarm is free from defects in material and workmanship under normal use and services for a period of ten 10 years from the date of purchase Master Distributors Pty Ltd agrees to repair or replace at its option any defective Smoke Alarm provided it is returned personally or by prepaid delivery with a copy of proof of purchase Do not post This warranty does not cover damage resulting from accidents misuse or abuse or lack of reasonable care of the product The purchaser s attention is drawn to rights it may have under the Trade Practices Act 1974 and similar state and territory legislation which cannot be excluded Subject to those non excluded rights and provi
7. n you must test the smoke alarm weekly and replace it every 10 years Note For best protection we recommend that you install a smoke alarm in every room SMOKE ALARM PLACEMENT Typical single story home Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 9 metres 30 ft long install a smoke alarm at each end If there is a basement Install a smoke alarm on the basement ceiling at the bottom of the stairwell KITCHEN O DINING ROOM O LIVING ROOM BEDROOM SINGLE STORY RESIDENCE APARTMENT MOBILE HOME Typical Multi story or split level home Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 9 metres 30 ft long install a smoke alarm at each end Please install a smoke alarm on the top of a first to second floor stairwell O A LIVING ROOM KITCHEN i af ter KEY MULTI STORY RESIDENCE Minimum required smoke alarm locations O Recommended additional smoke alarm locations Z Smoke alarms with hush features recommended for additional protection IMPORTANT SMOKE ALARM PLACEMENT AND EXCEPTION INFORMATION 1 Place as close to the centre of the ceiling as possible or at least no closer than 300mm to any wall or corner 2 Install a minimum of two smoke alarms in every home no matter how sma
8. reason the battery is removed drained or improperly connected DO NOT use any other kind of battery except as specified 2 DO NOT connect this smoke alarm to any other type of smoke alarm or auxiliary device except those listed inthis manual The Test button accurately tests all smoke alarm functions Do not use any other test method Test the smoke alarm weekly to ensure proper operation 3 DO NOT remove or disconnect battery to silence unwanted alarms This will remove your protection Open windows or ventilate the smoke alarm to silence it 4 This smoke alarm may be installed by a licensed qualified electrician Observe and follow all local and national electrical and building codes for installation 5 This smoke alarm is designed to be used inside a single unit dwelling only In buildings with several dwellings each individual living unit should have its own smoke alarms Do not install in non residential buildings This smoke alarm is not a substitute for a complete alarm system 6 Install a smoke alarm in every room and on every level of the home Smoke may not reach the smoke alarm for many reasons For example if a fire starts in a remote part of the home on another level ina chimney wall roof or on the other side of a closed door smoke may not reach the smoke alarm in time to alert household members A smoke alarm will not promptly detect a fire except in the area or room in which it is installed 7 Smo
9. red and the battery cannot be removed CLEANING Clean the smoke alarm at least once a month to remove dust dirt or debris Using the soft brush or wand attachment from a vacuum cleaner vacuum all sides and cover of smoke alarm Be sure all the vents are free of debris If necessary use a damp cloth to clean smoke alarm cover IMPORTANT Do not attempt to remove the cover to clean inside the smoke alarm This will void your warranty WARNING DO NOT disconnect battery to silence an unwanted alarm This will remove your protection Ventilate the unit or opena window to remove smoke or dust TROUBLESHOOTING Smoke alarm does not sound when tested PRACTICE FIRE SAFETY If the smoke alarm sounds its alarm horn and you have not pushed the test button it is warning of a dangerous situation Your immediate response is necessary To prepare for such occurrences develop family escape plans discuss them with all household members and practice them regularly 1 Expose everyone to the sound of asmoke alarm and explain what the sound means 2 Determine two exits from each room and an escape route to the outside from each exit 3 Teach all household members to touch the door and use an alternate exit if the door is hot Instruct them not to open the door if the door is hot 4 Teach household members to crawl along the floor to stay below dangerous smoke fumes and gases 5 Determine a safe meeting place for all me
10. second pause and felt then repeats AS3786 Lic 21554 SAI Global
11. sions and the above warranty Master Distributors Pty Ltd will not be liable for any injury to persons or damage to property or for any special direct or indirect or consequential loss or damage whatsoever and whether as a result of negligence or fault on the part of Master Distributors Pty Ltd or its servants agents suppliers and contractors or otherwise arising out of or resulting from whether directly or indirectly the use installation or maintenance of the smoke alarm and any warranties or representations are excluded unless given by Master Distributors Pty Ltd in writing If this Smoke Alarm is installed for use by others please leave this document or a copy for the end user 1 Check if the plastic tab is removed 2 Clean the smoke alarm See CLEANING NOTE Push test button for at least five seconds while testing Smoke alarm beeps about once a Low battery sign The smoke alarm should be replaced minute Smoke alarm sounds unwanted alarms intermittently or when residents are cooking taking showers etc The alarm sounds different than I m used to It starts and stops 1 Clean smoke alarm See CLEANING in the maintenance and cleaning section oS m 2 Move the smoke alarm to a new location E See SMOKE ALARM PLACEMENT The alarm is operating correctly This alarm features the 3 internationally recognised horn signal for evacuation The alarm sound pattern is 3 short beeps followed by a 2
12. y and operating properly 2 The push to test button accurately tests functions Do not use an open flame to test this smoke alarm You may ignite and damage the smoke alarm or your home 3 Test smoke alarms weekly and upon returning from vacation or when no one has been in the household for several days 4 Stand at arm s length from the smoke alarm when testing ke p Test amp Hush Button TEST ALL SMOKE ALARMS WEEKLY WITH THE FOLLOWING STEPS 1 Firmly push the TEST HUSH button and the smoke alarm will sound a loud beep The alarm will stop sounding after releasing the TEST HUSH button 2 If smoke alarm does not sound please retest the smoke alarm DANGER If the alarm sounds and smoke alarm is not being tested the smoke alarm is sensing smoke THE SOUND OF THE ALARM HORN REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION NUISANCE ALARMS If there is a nuisance alarm simply press the test hush button on the alarm to silence the unit for 10 minutes If when the alarm goes off there is no sign of smoke heat or noise to indicate that there is a fire you should get your family into a safe place before you start investigating Check the house carefully in case there is a small fire smouldering somewhere Check whether there is some source of smoke or fumes for example cooking fumes being drawn past the smoke alarm by an extractor If there are frequent nuisance false alarms it may be necessary to re locate
Download Pdf Manuals
Related Search
Related Contents
Auto Circuit Tracer Detector トマトジュースメーカー ファビオ Manual Mass Combi FR-SX 性能が快適な空間をつくる。 クラリオンの観光バス用機器 Mobile Mapping Software Option Getting Started Guide (4 languages) Neff D99W44 cooker hood EXEMPT CHILD CARE PROVIDER INFORMATION Procrastination I - metacontrol ingenieros MW_introduction_mono_1.01 Copyright © All rights reserved.