1.  the cable is not connect to each other  no short circuit  especially E  and  E    otherwise it will damage the transmitter    3 Except the adjustable electronic potentiometer  please do not change other organ of the transmitter    4 The transmitter should be installed in the place without any surge impact  Installation must be stable    and try to avoid bump  shouldn   t have strong corrosive gas around it     7  Judge troubles and trouble shooting    Please make sure the right connection and debugging according to the operating instruction   Please reference graph 1   If the users judge there is something wrong with the transmitter   s organ or the circuit board has been    damaged  please send the product back for repairing     8  Notice    1 Generally  the transmitter is matched with our strain type load cells  so there is a fixed inner    connection  and every potentiometer is sealed  If the user wants to connect or debug  please let us know   usually do not open the transmitter    2 The transmitter is not suitable for using in the insulation environment or powerful humid  environment    3 If the users want to connect the wire or debug by themselves  please reference the operating  instruction    4 The transmitter that is connected and debugged by our company  we can repair it when the  transmitter has troubles under normal use in one year     5 If you have some special requirement  please contact with us directly        Trouble Trouble shooting       NO Output   1  Chec
2. FD 4 Transmitter    User   s Manual    XIAMEN ELANE ELECTRONIC CO LTD    Dear users     Thank you for buying our product  FD 4 transmitter   please read this manual carefully  before use  and you are welcomed to contact with our technician when you meet some  problems     Summary    FD 4 is designed to match with our strain type load cells  can be widely used in the non   electrical measurement  situations that use strain type load cells  High precision  stable performance and easy use is our product characteristics    1 Suitable for strain type load cells    2 Can connect 1 4 load cells directly    3 Can protect reverse connect of voltage  and protect output    4 Two options  Electrical current voltage output    5 Multiple options of output capacity     Please indicate the type  current or voltage transmitter  and the output capacity when you order our transmitters     1  Specifications    1  Power supply  DC15V 24V     150mA MAX  2  Output  current 4 20mA or 0 10mA  Voltage 0 5V or 1 5V  3  Accuracy  Excelled 0 1 FS  4  The total sensitivity of connecting sensors   1 1mV V 2 2mV V   5  Resistance of load   lt 3509  current output    gt 250 2  voltage output    6  Operating temperature     20  C   85  C   7  Protection class  IP65    2  Electronic principle figure    Stable    voltage switch           TI GVOT       UV ous    1110119 019Z 1sn py    GND    3  Connection and potentiometer distribution       Figure      XS1 XS4  sensor end  the definition of each connection term
3. inal  from left to right  is as follows     E         excitation voltage positive pole  red   E          excitation voltage cathode  black   S          signal      white    S         signal      green     SHIE       shield  gray     RP1 RP4  Balanced potentiometers and the corresponding load cells are as follows     RP1        XS   RP3        XS3  RP2       XS2  RP4       XS4  XS5  output end  the definition of each connection terminal  from left to right  is as follows   V          power positive      red   V            power negative ground  black     SHIE       shield  naked wire    GND       ground  white    I   V        Current  voltage output positive  green   RPS  fully scale output adjustable potentiometer    RP6  initial output adjustable potentiometer    4  Connection of test system    Please see the figure 2   DColtage    TRANSMITTER             R   load resistance    gsl    gt    lt   2   O  SN   gt   D  O      e      n    Indicator and othe  equipment       Fig  2  Notice  When you order our voltage transmitter with the relevant sensor  you do not need to adjust  again  because we have adjusted it before leave our factory  please connect the test system directly  if    you only buy the transmitter  please connect the wire and adjustment as per the operating instrument     5  Adjustment    Open the cover  you can find the potentiometer and the terminal  see figure 1   Connect with  transducers  and put the transmitter into the system of measurement  figure 2   The
4. k power supply  2  Check voltage of E  and E   if power supply is good but  no excitation voltage please send back to our company  3  If the load cell has  excitation voltage but no output signal  please change load cell  4  For the current    transmitter  audion damage will also cause no output  please send back to company        No 1  Check voltage of E  and E  or S  and S   if load cell has excitation voltage   Reaction on   please change load cell  2  Check if sensitive output under real load is in the range   load if not  please change load cell  3  Calculating amplifier or V I or tracker damaged     please send back to the company           Output 1  Check if the load cell parameter changed  if changed  please readjust the  Abnormity   transmitter  2  Leach capacitor damaged or voltage switch circuit trouble  please    send back to the company  3  If load cell is abnormal  please change load cell              
5. n link the power  and turn it on    A  balanced adjustment   1 Load each sensor separately  and record the current  voltage output of each sensor under the load  condition    2 Count the average output  and use these data as a benchmark when adjust    3 Load on each sensor again separately  adjust the balanced potentiometer  RP1 RP2   and make  sure the output of sensor is the same with the benchmark    4 Repeat the step 1   3 mentioned above  there are some influence between each other when adjust the  potentiometer   until the output of sensor is the same the benchmark when load    B Output adjustment  after balanced adjustment    1 When the system is unloaded  adjust the preliminary output and the potentiometer  RP6   and make   the output reached the preliminary output    2 When the system is fully loaded  adjust the full output of potentiometer  RP5   make the output   reached the full scale output    3 If the output do not reached the preliminary output after the system is unloaded  adjust full scale load   may affect the preliminary output   repeat step 1  2 mentioned above  until the full scale output and    the preliminary output reach the standard     6  Installations and Usage    1 Connect strictly as per the definitions  especially pay attention to distinguishing transducers end and   output end  wrong connection will result in no output and damage    2 If there are any redundant cable conductors which connect to the sensor  you must tie up the  wire and make sure
    