GPRS/CSD/SMS security module GT7 User manual

image

Contents

1. ORVOS monitooring GPRS CSD SMS security module GT7 User manual Module version 1 26 Save a tree please don t print this document unless you really need to www orvos ee info orvos ee Security module GT7 transfers security control panel data to monitoring station via GSM network Primary alarm transmission channel to monitoring station either GPRS or CSD or SMS Back up alarm transmission channel to monitoring station either GPRS or CSD or SMS Signal strength and operating failure display Alarm transmission to monitoring station by 2 IP addresses and 2 GSM modem phone numbers Alarm transmission to up to 4 mobile phones by text SMS Remote configuration by GPRS connection is possible Remote uploading downloading of firmware by GPRS connection is fully supported Multilingual configuration software Simple installation by 4 wire serial connection Principles of operation Communicator GT7 receives data from Common bus Compatible with DSC PCS85 PC1565 PC5020 PC 1616 PC1832 PC1864 PYRONIX MATRIX 424 MATRIX 832 MATRIX 832 MATRIX 6 MATRIX 816 GE CADDX NX 4 NX 6 NX 8 Serial output Compatible with PARADOX SPECTRA SP5500 SP6000 SP7000 1727 1728 1738 PARADOX MAGELLAN MG5000 MG5050 PARADOX DIGIPLEX EVO48 EVO192 NE96 EVO96 PARADOX ESPRIT E55 728ULT 738ULT Telephonic communicator i e control panel transfers data to GT7 communicator through
2. Read after connection is checked configuration parameters will be automatically read after connection Click the button Restore in order to restore default parameters SN 000633 Ver 1 26 Connec ted www orvos ee info orvos ee 9 Select primary and back up data transmission channel in window Reporting GPRS amp GSM reporting and set parameters of network and receivers Pile Bs File About Disconnect F2 F8 Read Open Last F4 wite FE Open F3 Saes Select primary data transmission channel Pri mary ee amp GSM reporting Primary reporting Backup reporting GPRS E reporti n g 7 Text SMS reporting Server IP1 address Server IP2 address Z or Domain J Ja Select back up data transmission channel Backup reporting In active fields Enter receiver IP address Server IP address or Domain 195 22 175 1 Reaves Enter the receiver port Port m Enter GSM modem SIM card number Tel Order reer eee E 60239999 o country code without network operators code _ local number Enter access point name APN Fill fields User Name Password DNS1 and DNS2 by request of service provider or leave them blank Select transmission protocol from the list Protocol Enter a 6 digit data encryption code Encryption key Note this key has to be the same as entered into IP receiver Enter a duration of connection to the back up channel Return to primary aft
3. table Name Open Close Service Special oto Enter phone numbers T1 T2 T3 and T4 Order Text SMS relationships country code without network operator s code local number Enter object name Account this true name will be shown in the SMS message text when it is received Fill the list Partitions to start create texts of SMS messages transferred It s possible to change texts written in Area1 Area16 these true names will be shown in SMS message text when it is received If partitions are not created leave the list blank 12 Fill lists in window Reporting Users amp Zones to create SMS message texts transferred to mobile phone CE oix File About Connect Disconnect F2 F8 a toi em Enter user names by access codes who will have E Reportin Test SMS relaionstips possibility to arm disarm the security system User1 g GPRS amp GSM reporting UTEN ea ae User16 these true names will be shown in SMS Conga message text when it is received rae Enter names of security zones Zone1 Zone16 E these true names will be shown in SMS message text E 3 when it is received 13 Click icon Write or function key F6 to enter the set parameters into communicator s memory 14 Click icon Save or function key F5 to save the set parameters to file with extension gst 15 Click icon Disconne
4. user names partitions names event descriptions can be specified by the User Package content Security module GT7 the SIM card is not included GSM straight antenna 2 fittings DIN 7985 M3x6 Velcro type stick on two sided x10 cm Specifications Power supply DC 12 V up to 60 mA stand by running current up to 500 mA by alarm transmitting 850 900 1800 1900 MHz Primary reporting channel to CMS either GPRS or CSD or SMS www orvos ee info orvos ee Back up reporting channel to CMS either GPRS or CSD or SMS Alarm transmission to 4 mobile phones by text SMS up to 60 messages nput 1 NC type Output 1 OC type switching 30V DC and 100 mA Operating environment from 10 C to 50 C relative air humidity 80 when 20 C 85x65x25MmmMm Ci Dimensions 85 x65 x25 mm Description of the communicator GT7 GSM antenna connector GSM antenna connector LED indicators Terminal block SIM card holder USB socket Terminal block SIM card heider uur A USB socket y Nop Description of terminals block Meaning 12V supply clamp Common device ground clamp Synchronizing signal clamp Data signal clamp Input clamp NC type Output clamp OC type Operation of light indication Meaning No SIM card Configuration mode Registering to GSM network Communication has failed Data transmitting mode Stand by Number of red flashes indicates GSM signal level Fitting to control pan
5. C11 interface Outputs PGMs i e communicator transfers signal regarding the change of input state having received it through input expander CZ6 security module GT sends information received from the control panel to monitoring station by either GPRS or CSD or SMS If the connection has failed communicator will repeatedly attempt to restore it for n times number of attempts n can be set If the module GT7 fails to restore connection the module will automatically connect to the back up channel and send the unsent messages through it Duration of connection or attempts to connect to the back up channel can be set after which the communicator tries again to connect to the primary channel Security module GT7 sends signals PING for testing of communication Messages sent to monitoring station correspond to Contact ID table of codes Message receivers e Software based IP receiver AGSR Alarm GSM Signals Receiver Free AGSR receiver software available to operate with practically any central station software This software is designed to convert data received via GPRS to serial RS232 or Ethernet TCP IP The software emulates Surgard MLR2 DG This is free software and available with purchase of GT7 module Please contact us at info orvos ee e Hardware based receiver Linux AGSR10 Module can transform the data received from the security panel to text SMS messages and send them to up to 4 mobile phones Text of SMS message name of object
6. Flow control None s Yd onnection settings for module configuration and firmware updates Parity None Flow control None Click button Apply 6 Click icon Connect Disconnect 7 Click icon Read to read existing parameters Enter access code to allow configuration in the appeared window default 1234 8 Enter common communicator parameters in window Main alal l connect t F2 F8 Openia Save FS Enter account number Account Check box Hex to allow hexadecimal entering SIM Card PIN fo IZ GPRS ping time jos Enter SIM card PIN code SIM Card PIN If PIN code A 7 see g request is disabled leave it blank I Test ne p an Select the type of connected control panel from the list Backup reporting after 3 times Panel type Select a PING transmission to monitoring station channel GPRS CSD SMS ping time and enter PING transmission period Check the box Test time to activate message transmission Test function and specify the transmission Save access code Read after connection Restore defaults settings Restore F11 period Enter a number of attempts the communicator will try to restore primary communication after it has failed Backup reporting after After this number of attempts the communicator will try to connect to a back up channel for reporting Check the box Save access code in order for PC to remember the access code When the box
7. ct or function key F8 to disconnect from the communicator GT7 Click icon Open or function key F3 to open a saved configuration file Click icon F4 or function key F4 to open the last saved configuration file Setting operation parameters remotely when connected by GPRS connection Remote configuration can be done by using software ConfigGT7 when there is an active GPRS connection between IP receiver AGSR and the communicator GT7 Send an SMS message in appropriate form to activate GPRS connection Communicator will only respond to SMS messages if it receives a message from a phone whose number is entered into Main Settings CMS Phones list If the above discussed list is blank communicator will respond to SMS in an appropriate form from any mobile phone When GT7 receives this message it initialises the GPRS connection with IP receiver AGSR www orvos ee info orvos ee SMS structure CONNECT gpace1234spaceS ERVER 100 100 100 100spacePORT 1 0005 pace APN providerspaceUSR USEF space PSW PSWspaceENCR enc Description write the initial command word CONNECT write the 4 digit configuration access code default 1234 write the word SERVER and receiver IP address from which the configuration will be done instead of symbols 100 100 100 100 written in example write the word PORT and port of receiver from which the configuration will be done instead of 1000 write the word APN and acce
8. el s case 1 Set operation parameters see chapter Module configuration 2 Put activated SIM card into a holder as shown in the Note picture fe 1 Ask your GSM provider we eg about SIM card properties before transferring data via ty chosen channel 2 Disable PIN code request if 9 y necessary www orvos ee info orvos ee 3 Fit to control panel s case Drill holes on control panel s case 4 Screw on the GSM antenna 5 Connect wires to control panel See wiring diagrams 6 Switch on power supply 7 According to LED indications check GSM signal Note level Test data transmission If GSM signal level is not sufficient connect other type antenna Wiring diagrams fm il e oi iE nm 7 Wiring diagram to DSC Wiring diagram to Paradox Compatible with PC1616 PC1832 PC1864 Compatible with SPECTRA SP5500 SP6000 PC585 PC 1565 PC5020 SP7000 1727 1728 1738 MAGELLAN MG5000 MG5050 DIGIPLEX EVO48 EVO192 EVO96 NE96 ESPRIT E55 728ULT 738ULT a a rerai WG Sane eae a OUOU O NVIL Fy et AAA A c Z 7 e al BELL DAA COM POS COM ALK by m Tai O s JERR Sais aS i Wiring diagram to Pyronix Wiring diagram to Caddx Compatible with MATRIX 424 MATRIX 832 Compatible with NX 4 NX 6 NX 8 MATRIX 832 MATRIX 6 MATRIX 816 Module configuration Operational parameters can be set read modified and u
9. er When this time has expired communicator starts to restore connection to primary channel To modify and activate communicator generated messages list Special event codes open the window by double clicking on selected event s row and fill the appeared window Tel Event Subgroup 10 Enter 4 phone numbers by which monitoring station will be able to activate GPRS connection between communicator and IP receiver for configuration Fill fields Settings CMS Phones Box Slee a E jpen Last FA ite Fe OpenF3 Save IF Enter up to 4 phone numbers T01 T02 T03 T04 ai Sending a specified form SMS message from a phone which number is in this list allows activation of GPRS connection between communicator and IP receiver If fields are left blank this allows activation of GPRS connection by sending SMS out of every mobile phone Order country code without network operator s code local number www orvos ee info orvos ee 11 Specify distribution of the reports by type and user groups for the communicator to transfer control panel data to mobile phone by SMS in specific order Fill the window Reporting Text SMS reporting ioi xi File About PAEA Ta A TER omr sr Specify distribution of messages by type and phone an numbers i e to whom the what type of messages me ae m aE aamfede D O 0 T E should be transferred Check the
10. pdated by using configuration software ConfigGT7 Configuration is possible by two methods when communicator GT7 is connected to PC on site using USB cable and when communicator GT7 is remotely connected to IP receiver AGSR by GPRS connection www orvos ee info orvos ee Configuration software ConfigGT installation Download file ConfigGT7_ setup exe from www orvos ee and follow the installation wizard USB driver installation Microchip USB drivers mchpcdc inf are required for module GT7 USB connection to PC If Microchip USB drivers have never been installed to PC before Windows New Hardware Wizard window will appear To finish the installation choose Yes this time only click Next and follow the installation wizard www orvos ee info orvos ee Setting operation parameters when connecting by USB cable Switch on power supply Run the configuration software ConfigGT7 Choose the dialog language in window Main Settings Language Connect communicator to PC using USB cable Set parameters of comport in window Main Settings Comport ae ee cx Name write name of comport if its necessary eg File About Connec t Disconnec t F2 F 8 Read F7 Open Last Fa Write FB Open F3 Save F5 GT7_US B i Port select comport communicator GT7 is connected ie a to eg COM2 Port comm x Baudrate is Baudot rate E 1 15200 Data bits eb o M o Data bits 8 Paty None x Stop bit 1
11. ss point name APN instead of provider write the word USR and APN User name if required by the provider instead of user write the word PSW and APN Password if required by the provider instead of psw write the word ENCR and 6 digit data encryption code default 123456 instead of enc Notes 1 The word space Means space interval between symbols 2 If provider does not require APN User name and Password text space USR spacePSW space have to be written accordingly in the SMS message Actions after the SMS has been sent 1 Open the main window of IP receiver AGSR and select the row of communicator which parameters will be set 2 Run configuration software ConfigGT7 by right clicking on the appeared icon Config T7 Alarm GSM Signals Receiver AGSR 5 o x Fie Settings About Control Object state summary Refresh control Waiting for GPRS 1 m Refresh _Options ti Waiting for SMS 0 F Refresh every 5 4 seconds elres pien puons Summary Lost 0 Objects control Remove object oea ID l IP Phone number Communication state Level GPRS last ping GPRS ping interval GSM last ping GSM ping interval Device Waiting for GPRS message 9 12 01 409 22 51 41 30 N A N A G7 V Show incoming events V Show incoming PING s 12 01 09 22 51 37 PING Object 1234 Event code 760 Fe aba Click icon Connect in
12. the tool bar when the Connect Disconnect F2 F8 Read F7 Open Last FA Write F6 Open F3 Save F5 E z ConfigGT7 window will appear Word Connected a Disconnected indicates the state of GPRS SIM Card PIN IV GPRS ping time s connection Access Code I DATA ping time I SMS ping time ee Configuration procedure is the same as when BEENIE communicator is connected to PC on site using USB cable Filling fields and selecting parameters is anel type v i z necessary IV Save access code J Read after connection Restore defaults settings Disconnected