Home
Installation and User Guide
Contents
1. 87 Fig 2 a ee a a F 20 0 VAa i m 3 35 8 5 Mounting Hole Dimensions inches amp cm 22 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 3 2 Connecting Ethernet Media and Special Strain relief feature Note see also Cable Strain Relief Feature Section 3 4 The Magnum P62 Series Ethernet Switches P62F model illustrated here can be connected to the following three media types 1 OOBASE TX 10BASE T and 100BASE FX CAT 5 cables should be used when making 100BASE TX connections When the ports are used as 10BASE T ports CAT 3 may be used In either case the maximum distance for unshielded twisted pair cabling is 100 meters 328 ft For fiber port LOOBASE FX multi mode 50 125 or 62 5 125 microns cabling can be used whereas for single mode 9 125 microns cabling should be used Fiber cabling supports much longer cable distances and higher bandwidth than copper wiring Media IEEE Standard Connector Twisted Pair CAT 3 or 5 10BASE T RJ 45 Twisted Pair CAT 5 100BASE TX RJ 45 Fiber Multi mode 100BASE FX SC Fiber Single mode 100BASE FX SC NOTE 1 It is recommended that high quality CAT 5 cables which work for both 10 Mbps and 100Mbps be used whenever possible in order to provide flexibility in a mixed speed network since P80 series switch ports are auto sensing for either 10 and 100Mbps Note that the auto sensing function does not sense the cable typ
2. The serial Console port is provided on the right front of the Managed mP62 Switch to use the Console Management Interface CMI to manage all functions of the switch In addition the Link Loss Learn feature patent pending in mP62 s allows rapid operating recovery from a link loss The Link Loss Learn feature of the Magnum mP62 Ethernet Switch addresses issues that can occur when mP62 s are used in redundant network configurations such as when Spanning Tree Protocol STP is in use With the Link Loss Learn feature Magnum mP62s are better able to handle some fault recovery situations and they may improve network reliability and provide faster fault recovery accordingly Thus the immediate re learning of the addresses of the attached devices results in fast re routing of traffic in mP62s See http www garrettcom com mp62 htm for additional information and application information Without a redundant network topology the Link Loss Learn feature is of no known benefit and should be turned off Developed using unique thermal techniques patent pending mP62 s operate smoothly to a max of 75 C which is 5 C more than the P62F product ratings of 70 C Equipped with high thermal dissipation features patent pending power supply flexibility management MNS mP software capability and a convection cooled sealed case the mP62s are ideal for power utility plants substations roadside traffic control stations unheated or high tem
3. 100BASE TX CAT 5 UTP 100 m 328 ft 100BASE FX full duplex multi mode 2 0 km 6 562 ft 100BASE FX full duplex single mode 20 0 km 65 620 ft 100BASE FX full duplex single mode long 40 0 km 131 240 ft Operating Environment Ambient Temperature 40 F to 170 F for mP62 160 F for P62F 40 C to 75 C for mP62 70 C for P62F Cold start down to 20 C Storage Temperature 40 to 185 F 40 C to 85 C Ambient Relative Humidity 5 to 95 non condensing Altitude 200 to 50 00 ft 60 to 15 000m Plenum rated for above the ceiling installation in office areas IEC 529 rated IP51 holds out dust vertical water Operating Shock and Vibration Meets Bellcore GR 63 CORE Conformal coating tropical humidity protection optional request quote www GarrettCom com 3 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 Power Supply Internal 24VDC and 48VDC Power Supply Power Input Voltage 20 to 60 VDC auto ranging GND Power Consumption 10 watts typical DC DC Converter Rating 5VDC 2Amps Power Supply Ext 125VDC amp 250VDC PSX T for P62 Series 5V only Power Input Voltage 100 to 275 VDC nominal rating of 125 250VDC Power Consumption 15 watts typical DC DC Converter Rating 5VDC 3Amps Power Supply External AC Power Supply PSX A for P62F 5V and mP62 5V AC Power Connector IEC type male recessed at rear of Power Supply chassis Input Voltage 85
4. Magnum P62F AC 1MISSC Same as P62F AC 2MSC except one fiber port is 20km single mode SC includes PSX A unit Magnum P62F AC 2SSC Same as P62F AC 2MSC except both fiber ports are 20km single mode SC includes PSX A unit Magnum P62F AC NOF P62F DC Ethernet Switch six 10 100 RJ 45 and no fiber ports Has 16KB address table and 1 0MB packet buffers AC power input 85 260vac 47 63Hz worldwide auto ranging via PSX A Power Source Extended Temp a separate unit Steel case used as a heat sink designed for use in environmentally auto ranging Steel case used as a heat sink designed for use in environmentally challenged locations such as outdoors with extended temperatures Magnum P62F 2MSC 8 port Ethernet Switch with two 100Mbps full duplex switched fiber ports multi mode SC type connector and six half or full duplex switched RJ 45 10 100 auto negotiating ports Includes store and forward switching that filters and forwards data moving between the ports The internal switch has 16K nodes address table and 1MB packet buffers DC power input 20 60VDC auto ranging Steel case acts as a heat sink Rated for extended temperature Magnum P62F 1M1SSC Same as P62F 2MSC but with one multi mode SC type and one 20Km single mode SC fiber connectors Magnum P62F 2SSC Same as P62F but with two 20Km sgl mode SC type fiber ports Magnum P62F NOF P62F DC Ethernet Switch six 10 100 RJ 45 and no fiber ports Has 16KB address table and 1 0MB pack
5. board ships cell towers data communication huts and pedestals aeronautical installations and military sites A Magnum P62 Series hardened Switch is easy to install and use Addresses of attached nodes are automatically learned and maintained adapting the switching services to network changes and expansions Top mounted LEDs provide extra advantage for the user to observe the status information of each port The Magnum P62 Series Hardened Switches generate high www GarrettCom com 9 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 performance plug and play operation in a rugged package The high strength steel enclosure gives extra protection Each P62 Series Hardened Switch is non blocking on all ports and has large packet buffers and a 4K node address table for advanced performance A Magnum P62 Series Switch with store and forward switching ability filters all faulty packets to minimize traffic congestion 2 2 1 Magnum P62 Series chassis w fiber SC m m or s m connectors Magnum P62F 5V Magnum P62F The Magnum P62 Series chassis houses one main PC board The front side of the chassis has a half dozen RJ 45 twisted pair ports and two 100Mbps full duplex fiber ports one on each side of the RJ 45 ports as shown in the adjacent picture The fiber ports operate in full duplex mode only to provide higher bandwidth and longer distances on fiber All the LEDs are mounted on the top cover to convenient
6. case which acts as a heat sink Internal chip temperatures are only about 10 C above case ambient at steady state operation LED Indicators PWR Steady ON when power applied SPEED when LINK is ON ON 100Mbps OFF 10 Mbps LINK ACT Steady ON for LINK with no traffic blinking indicates port is transmitting receiving F H RJ 45 ports only ON full duplex OFF half duplex www GarrettCom con ss 4 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 MTBF Bellcore method Over 10 years MTBF Email sales GarrettCom com for details Agency Approvals UL Listed UL 60950 cUL CB CE Low Volt Dir amp Electro Magnetic Comp IEEE P1613 Class 2 Environmental Standard for Electric Power Subs See also Note for Power Substations in Section 2 2 5 and 3 2 1 Emissions meets FCC Part 15 Class A and ETSI Warranty Three years return to factory Made in USA Magnum P62 Series Hardened Switches Installation and User Guide 05 05 1 2 Ordering Information Magnum P62 Series 10 100 Ethernet Switch Magnum P62F AC 2MSC P62F AC Ethernet Switch with six 10 100 RJ 45 and two 100Mb FDX fiber multi mode SC type ports Has 16KB address table and 1 0 MB packet buffers AC power input 85 160vac 47 63Hz worldwide auto ranging via PSX A power source Extended Temp a separate unit Steel case used as a heat sink designed for use in environmentally challenged locations such as outdoors with extended temperatures
7. e over approx 400 meters can be achieved only if the following factors are both applied e The 100Mb fiber segment must operate in full duplex FDX mode and e The worst case OPB of the fiber link must be greater than the fiber cable s passive Attenuation Attenuation Cable loss LED aging loss Insertion loss safety factor 3 2 6 Connections to NICs which support Auto Negotiation RJ 45 ports The copper ports of Magnum P62 Series Hardened Switches will function properly with NICs Network Interface Cards which support Auto Negotiation and the Fast Link Pulse FLP coding for the LOOBASE TX signaling system When connecting a NIC to a P62 it may be necessary to reload the NIC drivers on the user device if the NIC has been communicating with a protocol other than 1OOBASE TX such as 1OBASE T When 100Mb speed is agreed and in use the 10 100 LED is steady ON It is OFF if there is no traffic or if 10 Mbps traffic 3 3 Powering the Magnum P62 Series Hardened Switch 3 3 1 Power P62F and mP62 models for 48V and 24V DC pwr input Each Magnum Model P62 Series Hardened Switch requires a DC power source from 20 60VDC The wide range of power input qualifies this product for use both in 24VDC as well as 48VDC environments The 24VDC or 48VDC power input provides an Ethernet networking product utilizing a special type of power supply with a proven high reliability record 29 6699 DC Power Terminals floating
8. option for P62 Series The Magnum P62 Series Ethernet Outdoor Switches are designed to operate in extended temperature applications and are suitable for use in environments with inhospitable high low temperatures In order to mount the P62 Series on a flat panel or wall see Section 3 1 2 above In order to mount the P62 Series on a DIN RAIL track order the optional bracket Model DIN RAIL P62 and use the DIN Rail mounting bracket procedure as illustrated in the picture below See also the GarrettCom web site at http garrettcom com dinrail htm Because of the hardened steel enclosure of the P62 Series it is heavy 3 5 Ib or 1 6 kg and it needs a robust DIN Rail bracket and proper care while mounting The Model DIN RAIL P62 mounting bracket has a latch for clip on attachment and will grasp the DIN RAIL track strongly If you are using the External AC Power Supply Model PSX order one of the Model DIN RAIL P62 mounting brackets for it also and mount it on the DIN Rail beside of the P62 Series base unit Because the P62 Series are closed boxes dist and dirt in the area are OK The DIN Rail option allows the P62 Series to easily mount on a DIN Rail track on a wall or in a metal enclosure for Industrial or extended temperature applications The DIN Rail kits are optional and need to be ordered as separate items e g Model DIN RAIL P62 30 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 This se
9. or 6 5ft to the m P62 F It is not recommended to use these ports in substation applications to interface to field devices across distances which could produce kigh greater than 2500V levels of ground potential rise GPR during line to ground fault conditions The m P62 F passes the 1613specifications for zero packet loss with fiber ports amp with RJ45 ports used as indicated here Connecting Fiber Optic SC type Snap In The following procedure applies to installations using SC type fiber connectors This procedure applies to ports using multi mode SC fiber connectors Before connecting the fiber optic cable remove the protective dust cap plug from the end of the fiber connectors exposing the ports opening Save the dust cover plug for future use in case the fiber cable needs to be unplugged for service Wipe clean the ends of the dual connectors with a soft cloth or lint free lens tissue dampened in alcohol Make certain the connectors are clean before connecting Then insert the square male connector into the SC female jack of the Fiber port connector until it clicks and secures Note One strand of the duplex fiber optic cable may be coded using color bands at regular intervals you should use the color coded strand on the associated ports at each end of the fiber optic cable segment Connect the Transmit TX port on the Magnum Fiber port to the Receive RX port of the remote device Begin wi
10. power output cord comes with a military style screw lock female plug for secure attachment to the P62 5V Switch Input Voltage 85 264 VAC 47 63HZ Auto ranging AC Power Connector EC type male recessed Wiring Pin out P62F 5V Power Adaptor Pin 1 gt ve voltage white wire in the cable Pin 2 gt ve voltage black wire in the cable Pin 3 gt chassis ground green wire in the cable 27 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 Pin 4 gt not used Power Output 5VDC 3Amps max Input Fuse for overload and short protection 3AG type 0 5 Amp spare is included Power Capacity 15 watts output 70 min efficiency Surge Protection over 150 joules with clamping at 800V 50A min Operating Shock and Vibration meets Bellcore GR 63 CORE Sections 4 4 1 and 4 4 3 NOTE For best results at high temperature fasten the metal case of the PSX A unit to be in contact with a vertical surface such as pedestal that has good heat conducting properties Remove rubber feet if present to enhance metal to metal contact and provide the best heat transfer away from the PSX A unit 3 3 3 Power the P62 5V w DC Pwr Supply PSX T at 125 250 VDC The rugged Magnum P62 5V Hardened Switch also supports 125V 250 VDC power through a separate Power Source unit the PSX T The wide range of AC power input qualifies this product for use worldwide in almost any temperature environment The 125 250 VDC powe
11. 0 0 eeeeeseeeeeeee 29 4 0 OPERATION srca iaraa SNS LETEA 4 1 Dual Speed Functionality and Switching seeesceeeeeeeeeeeneteeneees 4 2 Auto negotiation and Speed sensing 4 3 LED s for P62 Series Hardened Switch 4 4 Auto Cross MDIX Auto negotiation and Speed sensing on mp62 model only 33 5 0 TROUBLESHOOTING u ccssssssssesscssecssccnecessssesscessssessssesessssnessssserssseseosses 34 5 1 Before Calling for Assistance m 5 2 When Calling for Assistance cceeesessesesseeseeeeeessecseeseescesseeseeseenesaeeneegs 35 5 3 Return Material Authorization RMA Procedure cccceessessseeeseeeseeeees 35 5 4 Shipping and Packaging Information APPENDIX A WARRANTY INFORMATION Magnum P62 Series Hardened Switches Installation and User Guide 05 05 REVISIONS Rev J 05 07 Minor updates to power substation notes and logo change Rev J 05 05 minor updates Auto cross MDIX on RJ 45 ports DIN Rail mounting wording Rev I 11 03 Console port pin assignments added Rev H 08 03 The DC Power input range is corrected from 20 70VDC to 20 60VDC Rev G 03 03 This revision adds the DIN RAIL mounting options amp UL requirement for DC Rev F 11 02 This revision adds the Managed mP62 models Rev E 06 02 Changed Altitude spec and added Mechanical mounting drawing in 3 1 2 Rev D 01 02 This revision changes the installation proc and operating Temp range Rev C 11 01 This revision includes the mag
12. Int amp 125V 250VDC ext through PSX T The P62 Series switch is designed to support 20 60 VDC auto ranging power input int as well as 125V 250VDC through external PSX T DC power is highly reliable and convenient in out of the way locations Managed mP62 s with MNS mP software for Managed network The New managed mp62 armed with management functions including SNMP QoS STP Port based VLAN Port settings Password security BootP DHCP etc MTBF over 10 years per Bellcore calculation method Email sales garrettcom com for MTBF detail 17 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 2 6 Applications The P62 Series is designed specifically for harsh temperature environments and brings future proof fiber and widely used copper connectivity to out of the way sites Example 1 Magnum P62F In this example a Magnum P62F Hardened Switch performs roadside real time traffic data collection and transmits it to a remote control station over fiber Since multiple traffic control sites are long distances apart they are all connected in series to each other and to the central station Some local users using RJ 45 ports may operate at 100Mbps and some users and utility devices may run at 10 Mbps A Magnum P62 Series Hardened Switch serves this requirement economically and efficiently The six full and half duplex switched ports make the required setup simple for collection of traffic data The uncontrol
13. LED is steady ON to indicate LINK and blinking to indicate transmitting receiving The 10 100 LED is ON for 100Mbps and OFF for 10 Mbps when LINK is made For fiber ports the LEDs are the same except there is no F H LED because 10Mb is not possible There must be a device connected to the Magnum P62 Series unit via a cable A proper link LK light must be made between both devices at each end of the cable in order for each LINK LED to provide a valid indication of operating conditions 2 4 Frame Buffering and Latency The Magnum P62 Series Hardened Switch is a store and forward switch Each frame or packet is loaded into the Switch s memory and inspected before forwarding can occur This technique ensures that all forwarded frames are of a valid length and have the correct CRC i e are good packets This eliminates the propagation of bad packets enabling all of the available bandwidth to be used for valid information While other switching technologies such as cut through or express impose minimal frame latency they will also permit bad frames to propagate out to the Ethernet segments connected The cut through technique permits collision fragment frames which are a result of late collisions to be forwarded to add to the network traffic Since there is no way to filter frames with a bad CRC the entire frame must be present in order for CRC to be calculated the result of indiscriminate cut through forwarding is greater t
14. V NOF Same as mP62 NOF except w 5VDC input using military type screw lock connector Magnum PSX 5V CBL spare 2ft power cord with military type screw lock connector spare for PSX to mP62 5V power cord MST Conversion Special Item convert one standard P62 2MSC w two MSC fiber ports to two MST fiber ports PSX unit or equal required to supply 5VDC input For more information see the PSX datasheet Magnum P62 models with other fiber connector types and combinations available request quote GarrettCom Inc reserves the right to change specifications performance characteristics and or model offerings without notice Magnum P62 Series Hardened Switches Installation and User Guide 05 05 2 0 INTRODUCTION 2 1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product notify the carrier of any damage that you believe occurred during shipment or delivery Inspect the contents of this package for any signs of damage and ensure that the items listed below are included This package should contain 1 Magnum P62 Series Hardened Switch P62F xxx or mP62 xxx 1 Installation and User Guide 1 Product Registration Card Optional if AC power 1 PSX A Power Source Extended Temp unit 1 6 ft long AC Power chord for PSX A Unit only Optional PSX T 125 or 250VDC 1 PSX T Power Source Extended Temp unit Remove the Magnum P62 Series Hardened Switch from the shipp
15. a metal surface is necessary to allow the thermal heat transfer from the case achieving rated ambient temperature specifications The mP62 s can be mounted on any material 3 1 2 Mounting dimensions Each Magnum P62 Series Hardened Switch is normally mounted with screws in a vertical cables at the bottom position The base plate of the unit has screw holes cut out two top and two bottom The spacing for the mounting screws is a rectangle 3 35 x 7 92 8 5cm x www GarrettCom con lt s ss 21 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 20 1cm center to center Four user supplied screws 14 max diameter attach the P62 S base plate to the vertical mounting surface The PSX Power Source mounting is similar The mechanical drawings in Figures 1 amp 2 below provide the mounting holes measurement information for the PSX unit mounted on top if present and for the Magnum P62 Series unit 1 44 3 35 8 5 1 an M j Fig 1 6 18 sa 15 7 5 BAG r Magnum PSX A Power Source Extended Temp AC Input f m 3 35 8 5 1 64 3 35 8 5 E 4 2 7 Magnum P62F Ethernet Switching Hub 7
16. aged Fiber Switches Gigabit 100 and 10 Mbps fiber and copper ports mix and match Features SFF fiber for up to 25 fiber ports in a 1U unit Configurable 4K Series Switches 100 and 10 Mbps copper ports with optional 100Mb fiber ports regular and Reverse rack mount models AC and DC power options heavy duty specs Quad Series Fiber Switches 100 amp 10Mbps fiber and copper ports mixed speed and mixed media types full switching performance AC and DC power options P62 Series Outdoor Ethernet Switches for temperature uncontrolled applications 6 10 100 and 2 100Mb fiber ports managed and unmanaged models all fiber types Mixed Media Fiber Hub 16 port Stackable 10 100 auto sensing AC and DC power Dual Speed 8 port and 16 port Stackables 10 100 auto sensing AC and DC power cPCI Blade 12 port 10 100 hub on a card for Compact PCI chassis rear I O ITS Blade 8 port 10 100 switch on a card for Model 2070 Traffic Controller Chassis Stackable Hubs SNMP Optional 10Mb series and 100Mb series both w optional port modules AC and DC power Personal Switches 10 100Mb 8 port dual speed Auto negotiable with fiber option Personal Hubs 100Mb or 10 100Mb 8 port with two switched ports 1 fiber built in Personal Hubs 10Mb series 8 port AUI stackable to 5 high optional BNC of fiber port 8 or 9 port and 4 or 5 Port Personal Hubs w man up link sw Media Converters 10Mb and 100Mb series for offices and Harde
17. and email address listed below GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 7437 Phone 510 438 9071 Fax 510 438 9072 Website http www GarrettCom com email support garrettcom com Federal Communications Commission Radio Frequency Interference Statement This equipment generates uses and can radiate frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the users at their own expense will be required to take whatever measures may be required to correct the interference ll Magnum P62 Series Hardened Switches Installation and User Guide 05 05 MAGNUM ETHERNET CONNECTIVITY PRODUCTS DESIG NED AND MANUFACTURED IN THE USA Overview GarrettCom Inc offers the Magnum line of Ethernet LAN connectivity products with industry standard functionality Magnum products are heavy duty feature fiber built in ports and have AC and DC power options to make them suitable for a variety of Industrial and Carrier Class applications 6K25 Man
18. anty card as this acts as a product registration and mail it to GarrettCom within two weeks of your purchase www GarrettCom com 36
19. be adhered to in order to conform to UL requirements Minimum 18 AWG cable for connection to a Centralized DC power source Minimum 14 AWG cable for connection to earthing wiring Use only with Listed 10 A circuit breaker provided in building installation Complies with FDA radiation performance standards 21 CFR subchapter J or equivalent 5 Fastening torque of the lugs on the terminal block 9 inch pound max a Centralized DC Power Source cable securement use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block te ol de 3 3 2 Power the P62 5V models w Ext AC Power Supply PSX A The rugged Magnum P62 5V Hardened Switch mainly used in outdoor Ethernet applications at extended temperatures also supports universal AC power input from 85 275 vac 50 60Hz through a separate Power Source unit the PSX A The wide range of AC power input qualifies this product for use worldwide in almost any temperature environment The AC power source PSX A provides a rugged power supply enclosed in a metal case that also acts as a heat sink enabling extended application temperatures to be accommodated The PSX A also includes surge protection to withstand AC power input upsets such as might result from nearby lightening strikes Shock and vibration characteristics enable use in transportation applications such as road side boxes for traffic control The DC
20. carefully It is recommended that you use the original container if available Units should be wrapped in a bubble wrap plastic sheet or bag for shipping protection You may retain all connectors and this Installation Guide CAUTION Do not pack the unit in Styrofoam popcorn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping container 3 GarrettCom is not responsible for your return shipping charges Ship the package to GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 7437 Attn Customer Service APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants its products to be free from defects in materials and workmanship for a period of three 3 years from the date of shipment by GarrettCom During this warranty period GarrettCom will repair or at its option replace components in the products that prove to be defective at no charge other than shipping and handling provided that the product is returned pre paid to GarrettCom This warranty will not be effective if in the opinion of GarrettCom the product has been damaged by misuse misapplication or as a result of service or modification other than by GarrettCom GarrettCom reserves the right to make a charge for handling and inspecting any product returned for warranty repair which turns out not to be faulty Please complete the warr
21. ce The P62 Series advertises its capability for 10 or 100 Mbps speed and the device at the other end of the cable should similarly advertise respond and both sides will agree to the speed being used Depending upon the device connected this will result in agreement to operate at either 10 Mbps or 100Mbps speed When the LK ACT LED is ON steady ON indicates LINK with no traffic blinking ON indicates the port is transmitting receiving The port has auto negotiated for operation If a P62s RJ 45port is connected to a non negotiating device it will default to 10 Mbps speed and half duplex mode per the IEEE 802 3u standard 32 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 Magnum 4 3 LED s for P62 Series Hardened Switch POWER Illuminates GREEN steady on when power applied SELF TEST Indicates the self test at power up was not successful F H ON Full Duplex and Link OFF Half Duplex and or no Link LK ACT Per port steady ON for LINK with no traffic blinking indicates port is transmitting and receiving 10 100 Per port ON 100Mbps OFF 10 Mbps when LINK is made 4 4 Auto Cross MDIX Auto negotiation and Speed sensing on mp62 model only The RJ 45 ports on managed mp62 support auto cross MDI or MDIX in the auto negotiation mode according to the IEEE 802 3u standard No crossover cables are needed when connecting the 10 100 copper port of mp62 s to other unmanaged switches
22. ction describes the function and operation of the Magnum P62 Series Switches 4 1 Dual Speed Functionality and Switching The Magnum P62 Series Hardened Switch provide six 10 100 RJ 45 switched ports and two 100Mb fiber ports The architecture supports a dual speed switching environment with two built in full duplex future proof fiber ports The six RJ 45 copper ports equipped with auto negotiation capability The switched RJ 45 ports are full half duplex and auto sensing for speed See section 2 2 When the connected device is 10 Mbps P62s obey all the rules of 10 Mbps Ethernet configurations The 10 Mbps users share a 10 Mbps traffic domain and can communicate with 100Mbps users as well as 100Mbps domain Similarly the 100Mbps traffic obeys the rules of 100Mbps Ethernet and can communicate with 10Mb domain too All Magnum P62 units are plug and play devices There is no software configuration to be done at installation or for maintenance The Half full duplex mode for the RJ 45 switched RJ 45 ports is user dependent and changes by auto negotiation to full or half duplex as the unit attached with these ports The internal functions of P62 Series Switch is described below Switching Filtering and Forwarding www GarrettCom com 31 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 Each time a packet arrives on one of the switched ports the decision is taken to either filter or to forward
23. d download from Garrettcom s FTP site Or please visit www GarrettCom com techsupport index htm software and look for Magnum mP62 s MNS mP software support information Users can also email support GarrettCom com for further information 2 2 4 Connecting the Console Terminal to Magnum mP62 Management Use a DB 9 null modem cable to connect the Magnum mP62 Console Port the RS 232 port on the mP62 Switch to your PC so that your PC becomes the mP62 s Console Terminal Note The DB 9 cable is not included with the mP62 unit package Console port Fig 2 2 4 Front View of Magnum mP62 Console port is located on the extreme right of the Hardened Switch Note For a detailed description of Managed Network Software MNS mP and Magnum mP62 Hardened Switch configurations for Network Management please refer to the Magnum mP62 Software Manual available on GarrettCom s FTP site Information about MNS mP software is also available in Section 2 2 1 above of this manual 13 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 2 2 5 RS 232 DB 9 Console Com port pin assignments DB 9 Console port connector Pin Signal Description 1 CD Carrier detect not used 2 RXD Receive Data input 3 TXD Transmit Data output 4 open not used 5 GND Signal Ground 6 9 open not used The above provided information enables a managed station a PC or Console terminal to connect directly to the sw
24. diesasssdeestenansvdiasdegdesassassisusseats 14 2 4 Frame Buffering and Latency 0 cece escesesceeceeeeecseeseeseesceesseeesaeeseeaeeaeees 15 2 5 Features and Benefits ss i ectsssaied sesstavssesscagistassivvessoedvisasscostvedsssadeessvasssecesivats 17 2 6 Applications ee 3 0 INSTALLATION cccccssssssssssscssscssscnscessssesscesscsscssecsssnsssssesscssesnesssssessssesoosses 21 3 1 Locating Magnum P62F Series 10 100Mb Ethernet Switches 0 ee 21 3 1 1 Mounting position and materials eee eee eeeeeee wl 3 1 2 Mounting dimensions cece eee eeeseeeeeseeseeseeeeeeeeeeaee 3 2 Connecting Ethernet Media and Special Strain relief feature 23 3 2 1 Connect Twist Pair RJ 45 CAT 3 or CAT 5 Unshielded or Shield 23 3 2 2 Connecting Fiber Optic SC type Snap In 3 2 3 Connecting Fiber Optic ST type Snap In Optional 3 2 4 Connecting Single Mode Fiber Optic cece eeeeseeseeeeeceeeseeneeeeeees 3 2 5 Power Budget Calculations for P62 Series Fiber Media 0 ce 25 3 2 6 Connections to NICs which support Auto Negotiation RJ 45 ports 26 3 3 Powering the Magnum P62 Series Hardened Switch ccc eeeeteeeeeeee 26 3 3 1 Power P62F and mP62 models for 48V and 24V DC pwr input 26 3 3 2 Power the P62 5V models w Ext AC Power Supply PSX A 0 27 3 3 3 Power the P62 5V w DC Pwr Supply PSX T at 125 250 VDC 28 3 4 Cable Strain Relief Feature on all P62 Series models 0 0
25. e 3 2 1 Connect Twist Pair RJ 45 CAT 3 or CAT 5 Unshielded or Shield The following procedure describes how to connect a 1OBASE T or 1OOBASE TX twisted pair segment to the RJ 45 port The procedure is the same for both unshielded and shielded twisted pair cables ww GarrettCom com s _ gt 23 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 Using standard twisted pair media insert either end of the cable with a RJ 45 plug into the RJ 45 connector of the port Note that even though the connector is shielded either unshielded or shielded cables and wiring may be used Connect the other end of the cable to the corresponding device Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established If this does not help ensure that the cable is connected properly and that the device on the other end is powered and is not defective For Port 1 or 1SW if the LINK LED is not illuminated move the switch which has a cross over or up link for linking to another hub or Switch NOTE for Power Substations Jn support of the IEEE 1613 Class 2 standard GCI advises 3 2 2 3 2 3 that for substation applications the RJ 45 ports are intended for connectivity to other communication equipment such as routers or telecommunication multiplexers installed in close proximity i e less than 2 meters
26. eo GarrettGom Industrial Networking at Its Best Magnum P62 Series P62F and managed mP62 models Hardened Ethernet Switches Installation and User Guide www GarrettCom com 5 00 USD Magnum P62 Series Hardened Switches Installation and User Guide 05 05 Magnum P62 Series P62F and managed mP62 models Hardened Ethernet Switches Installation and User Guide Part 84 00092Z Rev J 05 05 Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom Magnum Personal Switch S Ring Redundancy Manager patent pending and Link Loss Learn patent pending are trademarks and Personal Hub is a registered trademark of GarrettCom Inc Important The Magnum P62 Series Hardened Ethernet Switches contain no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void If problems are experienced with a Magnum P62 Series Hardened Switch product consult Section 5 Troubleshooting of this User Guide Copyright 2005 GarrettCom Inc All rights reserved No part of this publication may be reproduced without prior written permission from GarrettCom Inc Printed in the United States of America Magnum P62 Series Hardened Switches Installation and User Guide 05 05 Contacting GarrettCom Inc Please use the mailing address phone and fax numbers
27. et buffers DC power input 18 60VDC auto ranging Steel case used as a heat sink designed for use in environmentally challenged locations such as outdoors with extended temperatures Parts Magnum P62F 5V 2MSC Same as P62F 2MSC except with 5VDC input using military type screw lock connector Magnum P62F 5V 1M1SSC Same as P62F 1 1SSC except with 5VDC input using military type screw lock connector Magnum P62F 5V 2SSC Same as P62F 2SSC except with 5VDC input using military type screw lock connector Magnum P62F 5V NOF Same as P62F NOF except with 5VFC input via PSX A using military type screw lock connectors Magnum PSX 5V CBL spare 2 ft power cord with military type screw lock connector spare for PSX to P62F 5V power cord Magnum PSX A P62F 5V Power Source for Extended Temperature nominal AC input 115 240vac at 47 63HZ auto ranging 15 watts 5VDC output at 3Amps Steel case used as a heat sink Extended temperature rated Output power cord has military style screw lock plug Mounts as a separate unit adjacent to a Magnum Model P62F 5V Switch Magnum PSX T Same as PSX A except 125VDC to 250VDC input terminal lugs for and GND www GarettCom com 6 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 Managed P62 Series mP62 Hardened Switches Magnum mP62 AC 2MSC mP62 AC Managed Switch with six10 100 RJ 45 and two 100Mb FDX fiber multi mode SC type ports Software inc
28. ets to cause flow control This tells the sending devices to temporarily stop sending traffic which allows a traffic catch up to occur without dropping packets Then normal packet buffering and processing resumes This flow control sequence occurs in a small fraction of a second and is transparent to an observer See Section 4 6 for additional details Another feature implemented in Magnum P62 Series Hardened Ethernet Switches is a collision based flow control mechanism when operating at half duplex only When the Switch detects that its free buffer queue space is low the Hardened Switch prevents more frames from entering by forcing a collision signal on all receiving RJ 45 half duplex ports in order to stop incoming traffic The latency the time the frame spends in the Hardened Switch before it is sent along or forwarded to its destination of the P62 Series Hardened Ethernet Switch varies with the port speed types and the length of the frame is a variable here as it is with all store and forward switches For 10 Mb to 10 Mb or 10 Mb to 100Mb or 100Mb to 10 Mb forwarding the latency is 15 microseconds plus the packet time at 1OMb For 100Mb to 100Mb forwarding the latency is 5 microseconds plus the packet time at 100Mb 16 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 2 5 Features and Benefits 100Mb switching services for high performance Ethernet LANs Magnum P62 Series Switches provide Fast E
29. ing container Be sure to keep the shipping container should you need to ship the unit at a later date To validate the product warranty please complete and return the enclosed Product Registration Card to GarrettCom Inc as soon as possible In the event there are items missing or damaged contact your supplier If you need to return the unit use the original shipping container Refer to Chapter 5 Troubleshooting for specific return procedures Magnum P62 Series Hardened Switches Installation and User Guide 05 05 2 2 Product Description The Magnum P62 Series Ethernet Outdoor Switches are designed to operate in extended temperature applications and are suitable for use in environments with inhospitable high low temperatures Magnum P62 Series Hardened switches provide two built in 100Mb full duplex switched fiber ports so that several units can be daisy chained These fiber ports are coupled with the convenience of six switched 10 100Mb copper RJ45 ports for easy connectivity to local nodes and devices All these features come in one compact rugged unit The Magnum P62 Series hardened Switches are available in a wide variety of options including our Managed mP62 version The Managed mP62 can be easily deployed in an existing and mixed vendor Ethernet network because of its features and capability The Managed mP62 equipped with MNS mP software supports managed edge switch functions including Menu driven User Interface fo
30. internally GND Terminal for earth or ground wire connection to the P62 chassis Input Voltage 20 to 60 VDC Input current 0 7 amp max Power Consumption 10 watts typical P62 48V 24VDC INSTALLATION This section describes the proper connection of the 48VDC leads or 24VDC leads to the DC power terminal block on the Magnum P62 Switch as shown in Figure above The DC terminal block on the Magnum P62 Series Hardened Switch is located on the left front of the unit and is equipped with three 3 screw down lead posts The power terminals are identified as positive and negative and they are floating inside the unit so that either may be grounded by the user if desired The chassis is earth or ground GND 26 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 The connection procedure is straightforward Simply insert the DC leads to the Switch s power terminals positive and negative screws The use of Ground GND is optional it connects to the Switch chassis Ensure that each lead is securely tightened NOTE Always use a voltmeter to measure the voltage of the incoming power supply and figure out the ve potential lead or ve potential lead The more ve potential lead will connect to the post labeled ve and the rest to the ve The GND can be hooked up at the last When power is applied the green PWR LED will illuminate UL Requirements The following must
31. itch using a straight through cable Note The Null Modem DB 9 cable is optional and can be order from the factory along with the unit NOTE for Power Substations Jn support of the IEEE 1613 Class 2 standard GCI advises that for substation applications the serial RJ 45console_ports are intended for temporary connectivity to other equipment such as PCs Since the console port connection is temporary it is excluded from IEEE 1613 packet loss testing per the 1613 standard defined test procedure 2 3 Fiber port SC Connectors The Fast Ethernet fiber switched ports on the Magnum P62 Series operate at fixed 100Mb speed and full duplex mode for the best performance The P62 s fiber ports are factory built as either a multi mode or single mode SC connector A yellow label on the fiber port ww GarettCom com I 14 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 connector will indicate if it is single mode Otherwise it is a multi mode port Each 100Mbps fiber port performs as a switched port and as a traffic domain providing a high bandwidth backbone connection that supports long up to 20km single mode or 40km special long reach fiber cable distances for installation versatility A fiber port of a P62F is shown here On Magnum P62 Series units there are three LED s for each of the RJ 45 switched ports The F H indicates full duplex when ON or half duplex when OFF The LK ACT
32. led outdoor temperature feature and high reliability of the P62F make it suited to the site The two 100Mbps full duplex fiber ports easily fulfill the long distance connection and provide high bandwidth for fast movement of data The advance design of sealed P62F takes care of it cooling method The mechanical design of the Magnum P62F also enables it to be easily placed in a NEMA 4 enclosure to provide an all weather outdoor solution Ce A V T Wt NEE y Figure 2 6 1 A P62F connects combinations of 10 Mbps and100Mbps network devices and provides a Fast Ethernet fiber backbone for access to the central control station Magnum P62 Series Hardened Switches Installation and User Guide 05 05 Example 2 The Magnum P62F fits very well in high temperature locations control rooms experiencing a need to scale its LAN quickly and cost effectively With its half full duplex switching capability the P62F provides a very economical high bandwidth solution at each copper cable user access point The 10 100 dual speed functions to support a mixed environment of 10 Mbps and 100Mbps users and devices The switching capability on all ports provides bandwidth for high performance The ruggedness of the P62F steel case and the high reliability of the design over 10 years of MTBF complements the temperature controlled packaging to provide an exceptional Ethernet product Server Figure 2 6 2 Three P62F connects together to pro
33. legacy hubs managed switches media converters etc Please note that there can be conditions with managed switches where the switch manager fixes the port settings via software and the result of the auto negotiation is changed in the managed switch by the manager commands In such cases the 10 100 speed or the F H mode may be affected but auto cross in themp62 Switches will still work The auto cross function can be disabled through software When an RJ 45 cable connection is made and each time LINK is enabled auto negotiation takes place except for legacy products which do not have auto negotiation and which go to the default state accordingly The Magnum Switch advertises its capability for 10 or 100 Mbps speed and F H duplex mode and the device at the other end of the cable should similarly advertise respond Both sides will agree to the speed and mode to be used per the IEEE 802 3u standard Depending upon the devices connected this will result in agreement to operate at either 10 Mbps or 100Mbps speed and full or half duplex mode ww GarrettCom com s s 33 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 5 0 TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments The installation Magnum P62 Series Hardened Switch is a straightforward procedure see INSTALLATION Section 3 the operation is also straigh
34. ludes menu driven user interface for ease of use SNMP QoS Telnet Security STP VLAN BootP DHCP Has 4Knodes address table and 256K packet buffers AC power input 85 260vac 47 63Hz worldwide auto ranging via PSX A Power Source Extended Temp a separate unit Steel case used a s a heat sink designed for use in environmentally challenged location such as outdoors with extended temperatures Magnum mP62 AC 1MISSC Same as mP62 AC 2MSC except one fiber port is 20km single mode SC includes PSX A Magnum mP62 AC 2SSC Same as mP62 AC 2MSC except both fiber ports are 20km single mode SC includes PSX A Magnum mP62 AC NOF mP62 AC Ethernet Switch w six 10 100 RJ 45s no fiber ports Magnum mP62 2MSC mP62 DC Ethernet Switch six 10 100 RJ 45 and two 100Mb FDX fiber multi mode SC type ports Software and buffers same as mP62 AC 2MSC Dc power input 20 60VDC auto ranging Magnum mP62 1MISSC Same as mP62 2MSC except one fiber port is 20km single mode SC No PSX unit required Magnum mP62 2SSC Same as mP62 2MSC except both fiber ports are 20km single mode SC No PSX unit required Parts Magnum mP62 5V 2MSC Same as mP62 2MSC except with 5VDC input using military type screw lock connector Magnum mP62 5V 1M1SSC Same as mP62 1M1SSC except w 5VDC input using military type screw lock connector Magnum mP62 5V 2SSC Same as mP62 2SSC except w 5VDC input using military type screw lock connector Magnum mP62 5
35. ly indicate operating status of all ports There is a power on PWR indicator and a SELF TEST self test at power up in progress or failed for the unit For each RJ 45 ports 2 7 there are Link and Activity LK ACT LEDs indicating traffic 10 100 ON for 100Mbps LEDs indicating speed and full half F H duplex indicators The fiber ports 1 and 8 have LK ACT indicators only The rugged design of the case using high strength rugged 18 gauge steel enables this product to withstand environments with inhospitable high low temperatures and makes it suitable for outdoors temperatures road side pedestals control rooms and military use For DC powered models the DC power plug connector or jack is in the left front of the chassis The DC Magnum P62 Series Model is typically used for power input of 24VDC or 48VDC only The DC input power supports a wide range from 20 60 VDC auto ranging DC power input is featured for high reliability and convenience in out of the way locations www GarrettCom com 10 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 The Magnum P62 5V models are available with an External Power Source Optional for power input of universal AC power using the Magnum PSX A unit The 125 250 VDC model PSX T input power supports a range of 100 275VDC and comes with input safety shield fuses and is diode protected against accidental reverse polarity connection The AC Power So
36. ned models for industrial applications All media combinations incl fiber ST SC mm single mode The X line of configurable MiXed Media products Stackable Concentrators SNMP optional 13 Ports Repeater Port Modules RPMs 6 types for Ethernet media Bridge Port Modules BPMs 4 types for segment isolation Transceivers 10Mb series Mini Transceivers and Coax Models May 05 111 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 TABLE OF CONTENTS PAGE 1 0 SPECTBICATIONG cscsssssssssscssssssscsscsssssssessssssssenecssssesssseseossessesssssersssessesseses 3 1 1 Technical Specifications c iicccccs csssssiscestacssaseconssesacesssatesgcesoasesatseasosesvevsevaseoase 3 1 2 Ordering Tniforimati onic sscsccicscccsticsscsscicisdsstaeioesscosscasaetuvenssuadived sanate caensseieseeseciiaid 6 2 0 INTRODUCTION cinnara iiser sene s aL EEEE 8 2 1 Inspecting the Package and Product cee eeseseeseeseeeceeceecseeseeeeeeeseeeraeeaeees 8 2 2 Product Description sisssissccsisesascsassssisasesehs cacesssasioasscasasinetaveaassssaiinasebesane aes 9 2 2 1 Magnum P62 Series chassis w fiber SC m m or s m connectors 10 2 2 2 Managed mP62 chassis with fiber SC m m or single mode ports 11 2 2 3 Managed Network Software MNS mP for Magnum mP02 12 2 2 4 Connecting the Console Terminal to Magnum mP62 Management 13 2 3 Fiber port SC Comme ctorsss aissiccaisescsedtiesccsats hecss
37. num P62F NOF and metal mounting Rev B 08 01 This revision includes the update of additional power source Rev A 04 01 This revision is the initial release of the P62F Hardened Switches user manual Magnum P62 Series Hardened Switches Installation and User Guide 05 05 1 0 SPECIFICATIONS 11 Technical Specifications Ports Performance Fiber and when an auto negotiating port is operating at 100Mbps Data Rate 100Mbps When an RJ 45 auto negotiating port is operating at 10 Mbps Data Rate 10 Mbps For mP62 models RJ 45 ports are S W controlled for speed and F H duplex crossover MDI MDIX is automatically handled Network Standards 100Mb Ethernet IEEE 802 3u LOOBASE TX 1OOBASE FX 10 Mb Ethernet IEEE 802 3 1OBASE T Auto sensing for speed IEEE 802 3u 802 3x flow control For managed mP62 models IEEE 802 1p QoS and 802 1d Spanning Tree For mP62 management software see Section 2 2 3 Packet Processing Between Domains is non blocking Filtering and Forwarding Rate from 100Mbps ports 148 800 pps max Filtering and Forwarding Rate from 10 Mbps ports 14 880 pps max Processing type Store and Forward Auto learning 4K address table 16K on P62F shared for all ports Packet buffers 256KB dynamically shared on all domains Latency not including packet time 100 to 10 Mbps Sus 10 to 100Mbps Sus Path Delay Value 50 BT on all ports Maximum Ethernet Segment or Domain Lengths 10BASE T Unshielded twisted pair 100 m 328 ft
38. ode SC The same procedures as for multi mode fiber apply to single mode fiber connectors Follow the steps listed in Section 3 2 2 above 3 2 5 Power Budget Calculations for P62 Series Fiber Media Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget To calculate the power budget of different fiber media installations using Magnum products the following equations should be used OPB Optical Power Budget P min Pr min where Pr Transmitter Output Power and Pp Receiver Sensitivity Worst case OPB OPB 1dB for LED aging 1dB for insertion loss Worst case distance Worst case OPB in dB Cable Loss in dB Km where the Cable Loss for 62 5 125 and 50 125um m m is 2 8 dB km and the Cable Loss for 100 140 Multi mode is 3 3 dB km and the Cable Loss for 9 125 Single mode is 0 5 dB km The following data has been collected from component manufacturer s HP s and Siemens web sites and catalogs to provide guidance to network designers and installers Fiber Speed Std km Port Mode fdx Module Std hdx P62 100Mb Multi 2 62 5 125 xMSC_ FX mode 0 4 50 125 P62 100Mb Single 20 xSSC FX mode 0 4 0 Long TT ap 4 mode Reach 0 4 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 Note The use of either multi mode or single mode fiber to operate at 100Mbps speed over long distances i
39. ood or metal surface or in free air Designed primarily for specific applications such as roadside traffic data collection and control stations unheated and or high temperatures locations above the ceiling mounts in commercial buildings industrial boiler rooms mines and quarries irrigation and pipeline facilities on board ships cell towers data communication huts and pedestals aeronautical installations and military sites the Magnum P62s support DC power input for high reliability and AC power for convenience in out of the way locations Locate the P62 Series unit near any AC power or any 20 60VDC three wire GND power source for DC models that is within the range of the unit When installing the unit be sure to maintain an open view of the top surface to visually monitor the status LEDs 3 1 1 Mounting position and materials The Magnum P62 Series Hardened Switch should be securely mounted in a vertical position with appropriate screws Rubber feet if any that would insulate the case from metal to metal contact with the mounting surface should be removed The full temperature rating of the P62F unit cannot be achieved if it is not properly mounted on metal The Magnum P62 Series Hardened switches are quite heavy 3 5 Ibs 1 6 Kg because of its 18 gauge high strength steel case enclosure Because of its weight it is very important to select a sturdy place and carefully attach it to metal surface Attaching P62F s to
40. perature industrial plant locations commercial building above the ceiling locations data communications huts and pedestals and military field operation sites When mounted in the field an mP62 is typically fastened vertically to a wall or pedestal with cables connected at the bottom to provide protection of the connectors from dirt and dust The managed mP62 Switch s package is IEC 529 rated IP51 and while not waterproof it can be placed in NEMA 4 boxes IP65 enclosures and similar waterproof enclosures to provide an all weather outdoor solution The AC DC Power Supply options for the Managed mP62 Hardened Switches are the same as for the other P62F models For detailed descriptions of Power Supply options see Section 3 3 2 2 3 Managed Network Software MNS mP for Magnum mP62 Magnum mP62 s come with licensed MNS mP software which allows a user to configure the Magnum mP62 as a Managed Hardened Switch and activate the Software features For additional information about MNS mP see the Magnum mP62 s Software User guide in pdf www GarrettCom com 12 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 format a separate document normally accessed via the web browser ftp ftp garrettcom com or FTP client program by ftp GarrettCom com using user mpuser password mpuser All the MNS mP Software related information and NEW releases related to MNS mP Software and Hardware for mP62 s can be accessed an
41. r source PSX T provides a rugged power supply enclosed in a metal case that also acts as a heat sink enabling extended temperatures to be accommodated The PSX T also includes reverse polarity protection to prevent damage in case the unit is accidentally hooked up backwards The DC power output cord comes with a military style screw lock female plug for secure attachment to the P62 5V Hardened Switch 29 6699 DC Power Terminals connection to the PSX T chassis Input Voltage 100 to 275VDC Power Output 5VDC 3Amps Input Fuse 3AG type 0 5 Amp spare is included Power Capacity 15 watts output 70 min efficiency Operating Shock and Vibration meets Bellcore GR 63 CORE Sections 4 4 1 and 4 4 3 PSX T INSTALLATION This section describes the proper connection of the 125V 250 VDC leads to the 125 250 VDC power terminal block on the PSX T Power Source as shown in Figure above The 125 250 VDC terminal block on the External PSX T is located on the left side of the unit and is equipped with three 3 screw down lead posts covered by a removable safety shield or internally floating GND terminal for earth or ground wire cover The power terminals are identified as positive and negative and they are floating inside the unit so that either may be grounded by the user The chassis is earth or ground GND The connection procedure is straightforward Simply insert the DC leads to the PSX T s power
42. r ease of use SNMP QoS Telnet Password Security Port Settings Control Spanning Tree Protocol Port based VLAN BootP DHCP etc The two built in fiber ports are designed with full duplex 100Mbps switched capability The six copper RJ 45 ports come with full half duplex 10 100 auto negotiating ability The Magnum P62 Series Hardened Switches provide the switching speed and the reliability to smoothly support multiple workgroups at 100Mbps or 10Mbps speed The optional fiber ports are normally configured and tested with Magnum P62 units in the factory and come available in multi mode and single mode SC type fiber connectors For special fiber port types request quote Designed specifically to operate in uncontrolled temperature applications the hardened Magnum P62 s high strength steel case functions as a heat sink to draw away the heat from the internal electronics and dissipate it The efficient design of P62 Series high strength steel cases can easily handle the extreme heat of 75 C 170 F mP62 or 70 C 160 F P62F and extreme cold of 40 C 40 F when properly installed see Sec 3 0 Applications for Magnum P62 Series Hardened Switches include roadside traffic data collection and control stations unheated and or high temperatures locations above ceiling plenum spaces see sect 3 3 1 for details and ceiling mounts in commercial buildings industrial boiler rooms mines and quarries irrigation and pipeline facilities on
43. raffic congestion especially at peak activity Since collisions and bad packets are more likely when traffic is heavy the result of store and forward operation is that more bandwidth is available for good packets when the traffic load is greatest To minimize the possibility of dropping frames on congested ports each Magnum P62 Series Hardened Switch dynamically allocates buffer space from an 1MB memory pool ensuring that heavily used ports receive very large buffer space for packet storage Many other switches ww GarrettCom com 15 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 have their packet buffer storage space divided evenly across all ports resulting in a small fixed number of packets to be stored per port When the port buffer fills up dropped packets result This dynamic buffer allocation provides the capability for the maximum resources of the Magnum P62 Series unit to be applied to all traffic loads even when the traffic activity is unbalanced across the ports Since the traffic on an operating network is constantly varying in packet density per port and in aggregate density the Magnum P62 Series Hardened Switches are constantly adapting internally to provide maximum network performance with the least dropped packets When the P62 Series Switch detects that its free buffer queue space is low the Switch sends industry standard full duplex only PAUSE packets out to the devices sending pack
44. terminals positive and negative screws The use of Ground GND is optional it www GarrettCom con TT 28 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 connects to the PSX T chassis Ensure that each lead is securely tightened then replace safety shield When power is applied the green PWR LED will illuminate NOTE 1 Always use a voltmeter to measure the voltage of the incoming power supply and figure out the ve potential lead or ve potential lead The more ve potential lead will connect to the post labeled ve and the rest to the ve The GND can be hooked up at the last NOTE 2 For best results at high temperature fasten the metal case of the PSX unit to be in contact with a vertical surface such as pedestal that has good heat conducting properties Remove rubber feet if present to enhance metal to metal contact and provide the best heat transfer away from the PSX unit UL Requirements The following must be adhered to in order to conform to UL requirements Minimum 18 AWG cable for connection to a Centralized DC power source Minimum 14 AWG cable for connection to earthing wiring Use only with Listed 10 A circuit breaker provided in building installation Complies with FDA radiation performance standards 21 CFR subchapter J or equivalent 10 Fastening torque of the lugs on the terminal block 9 inch pound max Centralized DC Power Source cable securement
45. tforward and is discussed in Section 4 Should problems develop during installation or operation this section is intended to help locate identify and correct these types of problems Please follow the suggestions listed below prior to contacting your supplier However if you are unsure of the procedures described in this section or if the Magnum P62 Series Hardened Switch is not performing as expected do not attempt to repair the unit instead contact your supplier for assistance or contact GarrettCom Customer Support 5 1 Before Calling for Assistance 1 If difficulty is encountered when installing or operating the unit refer back to the Installation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable Ds Check the cables and connectors to ensure that they have been properly connected and the cables wires have not been crimped or in some way impaired during installation About 90 of network downtime can be attributed to wiring and connector problems 3 Make sure that an AC power cord is properly attached to each Magnum P62 Series Hardened Switch unit Be certain that each AC power cord is plugged into a functioning electrical outlet Use the PWR LEDs to verify each unit is receiving power 4 If the problem is isolated to a network device other than the Magnum P62 Series Hardened Switch product it is recommended that the problem device is replaced
46. th the color coded strand of the cable for this first TX to RX connection Note the two male square end SC cable strands may be fastened together to plug as a unit Connect the Receive RX port to the Transmit TX port of the remote device Use the non color coded fiber strand for this The LINK LED for the fiber connector will illuminate when a proper connection has been established at both ends and when power is ON in the unit If LINK is not lit after cable connection the normal cause is improper cable polarity Swap the fiber cables at the fiber connector to remedy this situation Connecting Fiber Optic ST type Snap In Optional The following procedure applies to installations using ST type fiber connectors i e using 24 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 multi mode ST When connecting fiber media to ST connectors simply twist on the two round male connectors into the ST female jacks of the Fiber connector until it clicks and secures 3 2 4 Connecting Single Mode Fiber Optic When using single mode fiber cable be sure to use single mode fiber port connectors Single mode fiber cable has a smaller diameter than multi mode fiber cable 9 125 microns for single mode 50 125 or 62 5 125 microns for multi mode where xx xx are the diameters of the core and the core plus the cladding respectively Single mode fiber allows full bandwidth at longer distances about 20Km with the single m
47. the packet Packets whose source and destination addresses on the same port segment will be filtered constraining them to one port and relieving the rest of the network from processing them A packet whose destination address is on another port segment will be forwarded to the appropriate port and will not be sent to the other ports where it is not needed Packets needed for maintaining the operation of the network such as occasional multi cast packets are forwarded to all ports The Magnum P62 Series Hardened Switch operate in the store and forward switching mode which eliminates bad packets and enables peak performance to be achieved when there is heavy traffic on the network Switching Address Learning The Magnum P62 Series units have an address table capacity of 4K node addresses and are suitable for use in large networks They are self learning so that as nodes are added or removed or moved from one segment to another the P62 Series automatically keeps up with node locations An address aging algorithm causes least used addresses to fall out in favor of new frequently used addresses To reset the address buffer cycle power down and up 4 2 Auto negotiation and Speed sensing All six RJ 45 ports independently support auto negotiation for speed in 1OBASE T and 100BASE TX modes Operation is according to the IEEE 802 3u standard When a RJ 45 cable connection is made and each time a LINK is enabled auto negotiation takes pla
48. thernet switching on all ports They perform high speed filter forward operations on the traffic giving each port s segment a full 100Mb or possibly 10 Mb for RJ 45 ports of bandwidth Two future proof fiber ports with SC connectors Built in fiber ports may be ordered with 100Mb full duplex multi mode SC single mode SC and special order SSCL type connectors The fiber ports are set to full duplex mode No Media Converters needed All RJ 45 ports are auto negotiating support 10 100 full half duplex The auto negotiating RJ 45 ports on P62 Series with 10 or 100Mb speed and full half duplex mode selected by Ethernet standard IEEE 802 3u Top mounted LEDs for convenient viewing The LEDs that indicate operating status are on the top of the unit for easy viewing in any situation As the units are normally vertical for wall or pedestal mounting top surface viewing is most convenient Installation is Plug n Play operation is transparent to software The Magnum P62 Series forward packets from each domain that are needed on the other domains Internal address tables are self learning enabling users to change port connections or 10 100 domains without affecting operations Thermal design enables P62S to be used in temp uncontrolled applications The P62 s advanced thermal technique enclosed in rugged 18 gauge high steel used as a heat sink is designed specifically for uncontrolled applications 24VDC and 48VDC
49. to 264 VAC auto ranging Input Frequency 47 to 63 Hz auto ranging Power Consumption 15 watts typical Power Supply Rating 3Amps at SVDC Network Cable Connectors 6 RJ 45 shielded female ports and 2 fiber port 100Mbps Category 5 UTP STP fiber 50 125 62 5 125 mm or single mode at 9 125 micron 10 Mbps Category 3 4 5 UTP Note auto sensing does not sense cable type Full duplex Half duplex on copper RJ 45 switched Ports 2 to 7 All the RJ 45 ports support Full Half duplex and 10 100 speed each inde pendently auto negotiating on P62F models S W controlled on mP62 models Fiber Ports 1 and 8 The switched fiber ports 1 amp 8 are fixed at full duplex only 100Mb speed Mechanical Enclosure Rugged 18 gauge high strength steel case Metal mounting plate included Suitable for stand alone shelf pedestal or wall mounting The case also serves as a heat sink The metal mounting base is included 13 guage steel Without the base the box size is only 7 high Mounting holes in the base plate are a rectangle that measures 3 35 x 7 92 8 5 x 20 1 cm center to center See Section 3 1 2 for additional mounting details Dimensions wall mounted 1 70 in D x 5 75 in W x 8 8 in H 4 3 cm x 14 6 cm x 22 4 cm Weight 3 5 1b 1 6 kg Cooling method Convection with case operating as a heat sink Note Internal thermal materials and techniques patent pending conduct heat from the electronic elements inside to the steel
50. ulfill the network requirement The Managed mp62 equipped with STP VLAN QoS etc features provide a very economical and efficient solution to this requirement The advanced Link Loss Learn feature will provide a very secure and effective solution in this particular kind of environment The advanced Link Loss Learn feature along with Spanning Tree Protocol efficiently control the ring topology environment with faster fault recovery and thus will improve the network reliability The managed mp62 Hardened Switch is specially designed to operate in uncontrollable temperature applications and its wide variety of AC DC options also qualify this hardened Switch to deploy in harsh applications www GarettCom com 20 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 3 0 INSTALLATION This chapter provides instructions for installing Magnum P62 Series units 3 1 Locating Magnum P62F Series 10 100Mb Ethernet Switches The location of a Magnum P62 Series Hardened Switch is dependent upon the physical layout of the network The rugged 18 gauge sheet steel case that acts as a heat sink will normally protect the P62 Series from accidental damage in any application setting Install P62F models so that the metal case of the unit is in contact with a metal surface such as a pedestal in the earth or an equipment enclosure box which does not exceed the ambient rating of the unit Install mP62 models mounted vertically attached to any w
51. urce PSX A is equipped with a worldwide range of 85 264vac 47 63Hz and is auto ranging with SVDC 3Amp Power output For both models the military style screw lock plug provides a secure connection See Section 3 3 for detail description of the PSX A and PSX T external power sources 2 2 2 Managed mP62 chassis with fiber SC m m or single mode ports Magnum mP62 5V mP62 5V with the PSX A AC model The Managed mP62 model is equipped with industry standard network management and utility software operating features to make this Switch suitable to deploy in mission critical applications and in harsh environments It also has internal components rated at 85 C so that it can operate at higher 75 C ambient temperatures than the P62F models The MNS mP software supports managed edge switch functions including menu driven user interface SNMP QoS VLAN STP Port settings control Password security and BootP DHCP etc The virtual LAN supports the Port based VLAN only and is easily setup on the managed MP62 Switch to provide a secure and highly efficient network to its users The MENU driven MNS mP CLI software is user friendly and easily operated by the network user to configure the network as per their needs The neat appearance of the MENU driven MNS mP is specially developed to have its function configured easily by the users www GarrettCom com 11 Magnum P62 Series Hardened Switches Installation and User Guide 05 05
52. urn Material Authorization RMA Procedure All returns for repair must be accompanied by a Return Material Authorization RMA number To obtain an RMA number please use this URL https rma garrettcom com rma rma_request_noaccount php to fill out the form Please have the following information readily available Name and phone number of your contact person Name of your company institution Your shipping address Product name Serial Number or Invoice Number Packing List Number or Sales Order Number Date of installation Failure symptoms including a full description of the problem www GarrettCom com 35 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 GarrettCom will carefully test and evaluate all returned products will repair products that are under warranty at no charge and will return the warranty repaired units to the sender with shipping charges prepaid see Warranty Information Appendix A for complete details However if the problem or condition causing the return cannot be duplicated by GarrettCom the unit will be returned as No Problem Found GarrettCom reserves the right to charge for the testing of non defective units under warranty Testing and repair of product that is not under warranty will result in a customer user charge 5 4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom please follow these instructions 1 Package the unit
53. use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block 3 4 Cable Strain Relief Feature on all P62 Series models LENA The Magnum P62 Series Hardened Switches are designed to use in extended temperature environments which qualifying them to be used in roadside traffic data collection and control stations above the ceiling locations in commercial buildings etc They are usually mounted vertically so that the cables hang out the bottom There is a cable strain relief feature provided as part of the package n rr eee Sioa E design The Magnum P62 Series Hardened Switches have 207p ype a tie wrap holder as part of the base plate of the unit for cable a a strain relief The strain relief feature is applicable to power cables as well as to Ethernet cables both twisted pair copper and fiber Cable tie wraps can secure the cables and can be www GarettCom com 29 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 attached to the base plate HOOK provided at the bottom front of the unit In the event that the attached cable is pulled the tie wrap cable strain relief feature protects the cable connection from coming loose This feature provides a more reliable and robust installation and operation The figure above of a P62F model illustrates the strain relief feature using tie wraps 3 5 DIN Rail mounting
54. vide 10 Mbps and100Mbps network with Fast Ethernet backbone In this example the extended temperature rated P62F takes care of the LAN connectivity requirement in a harsh temperature environment mounted above the ceiling in the building The non conductive fiber cabling inter connects these switches through their fiber ports providing a protected Ethernet network facility as part of the building infrastructure The steel enclosure and 20 60VDC power input qualifies the Magnum P62F to provide a dependable solution for any temperature un controlled location environments The rugged enclosure with cable strain feature gives extra protection and security to the cabling to hold the copper and fiber cable more securely with the Switch ports www GarrettCom com 19 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 Example 3 Magnum mP62 i penina ica Fig 2 6 3 The Magnum Managed mP62 in a ring topology application In an uncontrolled temperature environment where the data mining needs to be securely collect in a repository connected to the same Ethernet network its best to develop a redundant network path in a ring topology so that all the important data mining should not be interrupted by any faulty disconnect of any cabling The area covered for this ring Topology network is 12Km The managed mp62 loaded with MNS mP software with its two fiber ports can be easily deployed in a ring topology application to f
55. with a known good device Verify whether or not the problem is corrected If not go to Step 5 below If the problem is corrected the Magnum P62 Series Hardened Switch and its associated cables are functioning properly 5 If the problem continues after completing Step 4 above contact your supplier of the Magnum P62 Series Hardened Switch unit or if unknown contact GarrettCom Inc by fax phone or email support garrettcom com for assistance 34 Magnum P62 Series Hardened Switches Installation and User Guide 05 05 5 2 When Calling for Assistance Please be prepared to provide the following information 1 A complete description of the problem including the following points a The nature and duration of the problem b Situations when the problem occurs c The components involved in the problem d Any particular application that when used appears to create the problem 2 An accurate list of GarrettCom product model s involved with serial number s Include the date s that you purchased the products from your supplier 3 It is useful to include other network equipment models and related hardware including personal computers workstations terminals and printers plus the various network media types being used 4 A record of changes that have been made to your network configuration prior to the occurrence of the problem Any changes to system administration procedures should all be noted in this record 5 3 Ret
Download Pdf Manuals
Related Search
Related Contents
Kyocera FS-C8500DN User's Manual TRBOnet Dispatch Software User Guide Yamaha TSX-80 PDF-Bedienungsanleitung - KOMETEC, Online Samsung WF9654SQR 用户手册 PMDX Optical Sensor User`s Manual Revision 0.4 Da-Lite Professional Electrol 13'6" x 18' Splash Drone Quick Guide MANUAL DE USUARIO - Inicio Ventanilla Única Copyright © All rights reserved.