1. applications Embedded in each device the Z Wave smart chip enables two way RF communication among hundreds of Z Wave enabled devices allowing products and services from multiple 4 Prepare the Controller to include a unit to the network by adding it to a group method manufacturers to work seamlessly of adding a node to the network Refer to controller instructions 5 If your Controller supports Network Wide Inclusion NWI locate the WAPIRZ 1 near Linear Z Wave products are easy to install and allow dealers to create an the proposed installation location If not skip to Step 7 integrated wireless network with nearly limitless expansion and interoperability 6 With your Controller in Inclusion mode you should see an indication on your with security and health monitoring systems energy management home entertainment appliances and more For indoor use only Retain instructions for future use Controller that the device was included in the network It should display binary switch Linear The LED will stop blinking Skip to Step 10 If the LED does not stop blinking relocate the WAPIRZ 1 to within 100 feet line of sight of a Z Wave device or your hub and repeat Step 6 If the LED continues to blink your Controller does not support NWI and continue with Step 7 7 Place the WAPIRZ 1 within 3 feet of the Controller 8 With your controller in Inclusion mode depress the Tamper switch for 1 second then TEMPERATURE MONI
2. ICES A Z Wave network can integrate devices of various classes and these devices can be made by different manufacturers just as the WAPIRZ 1 can be incorporated into existing Z Wave networks Copyright 2014 Linear LLC PACKAGE CONTENTS e WAPIRZ 1 with Wall mounting bracket e Double sided mounting tape e CR123A Battery e Installation Manual REGULATORY INFORMATION The WAPIRZ 1 is certified to comply with applicable FCC and IC rules and regulations governing RF and EMI emissions This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference received that may cause undesired operation FCC Notice This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipm
3. TORING The PIR uses the SENSOR_MULTILEVEL_V4 command class to report to the Z Wave Hub a change in the ambient temperature of 1 degree Every rise or release drop of 1 degree will trigger a notification to the Hub Itis up to the Hub and how 9 You should see an indication on your Controller that the device was included in the the consumer programs it to determine actions based on these notifications network It should display binary switch Linear The LED will stop blinking DETECTION PATTERN 10 The device will appear in the list of Switches v NOTE If you have trouble adding the WAPIRZ 1 to a group it may be that the Home ID and Node ID were not cleared from it after testing You must first RESET UNIT 750 with your controller to remove it from the network Although adding it to a group DETECTION includes it in the network removing it from a group does not remove it from the Hale ay ganea network If removed from a group it functions as a repeater only RESET UNIT SIDE VIEW removes it completely from the network 6 For Association with another device The motion detector supports one association group with up to 5 nodes 1 Set up the Z Wave Interface Controller into association mode and following its 3 instruction to associate the WAPIRZ 1 with another device 2 Open the motion detector case to wake the unit In the Controller associate the detector with the other device 0 3 Close the m
4. WAPIRZ 1 Radio Frequency Controlled Wireless Passive Infrared PIR Motion Detector near Building On Innovation Tamper Switch Tab to release cover Adhesive Tape W Keep the surface of sensor and lens clean Program Switch wipe with clean and soft cloth Battery NOTE This unit must be included in the Network only where it will be permanently installed The proper operation of this node in the mesh network is dependent on it knowing its location with respect to other nodes You cannot test bench configure this module then install WAPIRZ 1 WIRELESS PIR MOTION DETECTOR INSTALLATION Linear s family of Z Wave certified wireless lighting controls switches 1 Release the cover tab to open the cover dimmers outlets and plug in modules and Security devices alert sounder 2 Insert a CR123A battery into the battery compartment and LED will start to flash passive infrared sensor and door window transmitter brings a new level of slowly which means the sensor has not yet performed inclusion with the controller intelligent wireless capability to commercial and residential environments 3 Replace the cover For Inclusion to adding to a network Refer to your Controller operating instructions to add this module under the command of the Wireless Controller The Z Wave wireless protocol is an international wireless standard for remote home automation security and other
5. ent off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician to help e Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment WARRANTY This Linear product is warranted against defects in material and workmanship for twelve 12 months This warranty extends only to wholesale customers who buy direct from Linear or through Linear s normal distribution channels Linear does not warrant this product to consumers Consumers should inquire from their selling dealer as to the nature of the dealer s warranty if any There are no obligations or liabilities on the part of Linear Corporation for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property revenue or profit or cost of removal installation or reinstallation All implied warranties including implied warranties for merchantability and implied warranties for fitness are valid only until Warranty Expiration Date as labeled on the product This Linear LLC Warranty is in lieu of all
6. other warranties express or implied All products returned for warranty service require a Return Product Authorization Number RPA Contact Linear Returns at 1 855 546 3351 for an RPA and other important details IMPORTANT Linear radio controls provide a reliable communications link and fill an important need in portable wireless signaling However there are some limitations which must be observed e For U S installations only The radios are required to comply with FCC Rules and Regulations as Part 15 devices As such they have limited transmitter power and therefore limited range e A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies regardless of code settings e Changes or modifications to the device may void FCC compliance e infrequently used radio links should be tested regularly to protect against undetected interference or fault e A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer and these facts should be communicated to the ultimate users P2068 X3
7. otion detector case ote Sole renee et Pte For Exclusion from removing from a network ALL UNITS 1 Set up the Z Wave Interface Controller into exclusion mode and following its ARE IN FEET instruction to delete the WAPIRZ 1 from the controller 2 Press the Tamper switch of WAPIRZ 1 for 1 second and release to be excluded The LED light will flash continuously when the sensor is in the Exclusion condition Mounting The motion detector should be mounted on a wall or in a corner 6 feet above the floor Use the double sided tape supplied to mount the detector y NOTE The passive infrared sensor detects motion by sensing fast changes in temperature when a person moves through the detector s field of view DO NOT MOUNT THE DETECTOR IN A LOCATION WHERE HEAT SOURCES HEATERS VENTS ETC ARE IN THE DETECTOR S FIELD OF VIEW False activation may occur BASIC OPERATION e During normal operation without detecting any motion the detector s red LED will be off e When the sensor detects motion it will send a status of ON Basic Set Value OxFF and alarm report Type 07 Level OxFF to any associated nodes The red LED will flash once e When no movement is detected for 3 minutes adjustable by configuration setting the detector will send a status of OFF Basic Set Value 0x00 and alarm restore report Type 07 Level 0x00 to any associated nodes then the unit assumes sleep mode e The motion de
8. tector is equipped with a tamper switch If the cover of the detector is removed it will send an alarm report Type 07 Level OxFF and the red LED will light constant CONFIGURATION The WAPIRZ 1 supports the Configuration command The WAPIRZ 1 can be configured to operate slightly differently than how it works when you first install it Using the Configuration command you can configure the following Parameter 1 Re trigger Wait Time By default to conserve battery life after the WAPIRZ 1 detects motion it cannot be re triggered by motion again for 3 minutes Each time motion is detected even during this wait time the 3 minute timer starts over The length of the re trigger wait time can be adjusted with this setting e Parameter No 1 e Length 2 Bytes e Valid Values 1 255 minutes Default is 3 Default Setting The configuration Parameter can be set to its default setting by setting the default bit in the Configuration Set command See your controller s instructions on how to do this and if it supports it All configuration commands will be reset to their default state when the WAPIRZ 1 is excluded from the Z Wave network by using the controller to reset the node SPECIFICATIONS Battery CR123A Lithium Battery Frequency 908 42 MHz Operating Temp 5 F 140 F 15 C 60 C Repeater Yes Range Up to 100 feet line of sight between the Z Wave Controller and or the closest Z Wave Repeater INTEROPERABILITY WITH Z WAVE DEV