Home

MODEL: DC10RCDH / DC12RCDH PORTABLE AIR CONDITIONER

image

Contents

1. The air conditioner is not level The distance between the remote control and the air conditioner is too far Move closer to the air conditioner Aim the remote control directly at the control panel Replace the batteries If you have any issues with your unit please contact Glen Dimplex on 1300 556 The remote control does not function The batteries are flat 816 for your nearest service agent Proof of purchase is required at the time of service 12 WARRANTY The warranty period is 24 months from the date of purchase Glen Dimplex Australia Pty Ltd Glen Dimplex New Zealand Ltd Unit 1 21 Lionel Road 38 Harris Road East Tamaki Mount Waverley VIC 3149 Manukau Auckland 2013 Australia New Zealand Ph 1300 556 816 Ph 09 274 8265 Fax 1800 058 900 Fax 09 274 8472 Web www dimplex com au Web www dimplex co nz DISPOSAL Do not dispose of electrical appliances as unsorted municipal waste Use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the ground water polluting the food chain and damaging health and well being 13 SPECIFICATION Model No DC10RCDH DC12RCDH 220 240V 50H2 200 240V 50H2 Power Consumption 1153W 967W 1346W 1129W EN14511 Rated Power EN60335 1280W 1100W 1480W 1300W Cooling Heatin
2. Fig 2 onto the unit s grille as shown in Fig 3 Attach the exhaust hose Fig 4 onto the exhaust hose attachment Fig 2 by rotating it in a clockwise direction Fig 2 Fig 4 Fig 5 Once complete ensure the outlet exhaust is attached to the window when using the heating function Reverse the process for cooling or dehumidification HUMIDIFYING When using the humidifying function remove the exhaust hose and fix the outlet grille on the unit 1 Fill the water filler and select humidifier function 2 The unit will stop automatically after four hours of operation Put water into the water filler to restart operation The unit will stop humidifying if the ambient humidity is equal to the pre set humidity WATER DRAIN Error code E4 When the air conditioner is used excess water condensation may be produced that will fill the water tank When the water tank is full the unit will stop working and display an E4 error code This means the unit will need to be drained as follows 1 Switch off and unplug the unit 2 Remove the water tank and pour out the water 3 Put the water tank back to original position 4 Restart the unit CONTINUOUS DRAINAGE To continually drain the unit in dehumidifying mode follow below steps 1 Switch off and unplug the unit 2 Remove the water tank and pour out the water 3 Remove drain plug Fig 1 4 Plug draining tube to draining hole Fig 2 5 Put the water tank back to or
3. er X lt Dimplex MODEL DC10RCDH DC12RCDH INSTRUCTION MANUAL U ii AANA PORTABLE AIR CONDITIONER IMPORTANT INFORMATION Carefully read this instruction manual before you install or use your portable air conditioner Please retain this manual for product warranty and for future reference CAUTION 1 Make sure the inlet and outlet vents are never blocked 2 Ensure the appliance is on a stable even surface when operating to avoid water leakage 3 Do not operate this unit in an explosive or corrosive atmosphere 4 When switched to cooling only operate this unit in ambient temperatures between 17 C and 43 C For heating only operate this unit in ambient temperatures between 5 C and 23 C 5 Clean the air filter frequently to ensure efficient operation 6 To prevent compressor damage when the unit has been operating and is turned off please wait at least 3 minutes before restarting 7 This unit needs to be plugged into 220 240V 50Hz AC 10 Amp power outlet 8 Do not use any extension cords with this unit 9 This unit is for indoor operation only 10 Open the adjustable air vent and extend the exhaust pipe and drain pipe if fitted to the closest window before using 11 Only ever have a professional technician manufacturer or service agent replace a damaged power cord 1
4. 2 The batteries from the remote control must be removed and disposed of safely before the appliance is scrapped 13 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety 14 Children should be supervised to ensure that they do not play with the appliance Important The air conditioner must always be stored and transported upright In case of doubt we suggest you wait for at least 24 hours before operation Please keep unit upright at all times PACKAGE CONTENTS Portable air conditioner Remote control User manual Extendable window kit PARTS 1 Control panel 2 Remote control receiver 2 3 Adjustable air vent 1 4 Window kit adaptor 3 5 Exhaust hose 6 Hot air filter 7 Hot air inlet 8 Home for remote control 9 Hot air outlet 10 Water filler for humidifying 15 function 9 11 Cool air filter 12 Cool air inlet 13 Water tank 14 Drain hole 15 Outlet grille for heating and humidifying 16 Exhaust hose attachment CONTROLS AND DISPLAY 6 8 5 7 2 3 1 4 1 POWER Press the POWER button to turn the unit ON or OFF The portable air conditioner is fitted with a compressor delay protection circuit This
5. adjusted the new setting is shown before the display returns to the current set temperature X The display is also used to show error codes should a fault occur see ERROR CODES 6 SPEED Press SPEED to select TURBO HIGH LOW or AUTO fan speed If AUTO fan speed is selected the unit operates at maximum capacity and turbo fan speed while the room temperature is more than 2 C from the set temperature When the room temperature is within 2 C of the set temperature the unit operates at HIGH fan speed Once the room temperature equals the set temperature the unit will operate at minimum capacity and low fan speed to efficiently maintain the desired temperature When TURBO HIGH or LOW speed is selected the unit operates at maximum capacity until the set temperature 4 7 TIMER 8 SLEEP is reached The fan operates at the selected speed ON OFF button for the programmable timer The timer can be used to turn the unit on automatically after a set time delay is complete 1 With the unit OFF press the TIMER button to set the desired time delay before you wish the unit to start 2 Choose the function desired cooling dehumidifier heating or humidifier 3 Once the set time delay is complete the unit will turn on automatically 4 If you press the POWER button before the time delay is complete the delay will be cancelled and the unit will turn on immediately The timer can be used to turn the unit off auto
6. aust hose 2 Remove the outlet grille and install the exhaust tube by rotating it clockwise onto the rear air outlet Please ensure fully inserted before use To remove the exhaust hose please rotate in an anti clockwise direction gt S 5 P3 j Fig 2 Locating the unit Install the portable air conditioner in a flat location with adequate space to ensure the air inlets and outlets will not be blocked Keep a minimum clearance of 50cm from walls and other objects Position the unit to allow the exhaust hose to reach a suitable window as shown Avoid sharp bends or kinks in the exhaust hose The optional adjustable window slider is included to ensure the exhaust hose is held in place in the window and prevents expelled hot air re entering the room The appliance should not be used in damp areas such as a laundry or bathroom Do not place the unit where it will be in direct sunlight as it may overheat and turn off ADJUSTABLE WINDOW SLIDER KIT The adjustable window slider kit is installed as shown below Window slider kit min 55cm max 100cm Window slider kit min 55cm max 100cm HEATING COOLING DEHUMIDIFYING When using the heating function remove the exhaust hose Fig 2 and replace the opening Fig 3 with the outlet grille as shown in Fig 4 Fig 2 Fig 4 the opposite end install the exhaust hose attachment
7. ease contact an authorized service centre if any of the above error messages are shown E4 Indicates the water tank is full Refer to WATER DRAIN If error code E4 persists please contact an authorized service centre 11 TROUBLE SHOOTING Never try to repair or dismantle the air conditioner yourself Unauthorized repairs may result in the loss of warranty and can endanger the user and their property The air conditioner does not Connect to a functioning power supply No power supply socket and switch on 2 Bis coge ae SNOWN Empty the internal water container Refer to indicating the internal water WATER DRAIN container is full operate The start timer function is Press the POWER button to deactivate the active TIMER function The air conditioner is in direct Bice th ciane sunlight Windows or doors are open Close windows and doors Clean the filters Remove the blockage Lower set temperature Place the air conditioner on an even solid surface The air conditioner does not seem to operate efficiently The filters are dirty The air inlets or outlets are blocked The room temperature is below the set temperature The air conditioner is noisy The Wait 30 minutes until the temperature has compressor The overheat protection is decreased then restart the air conditioner does not activated Note Compressor operation begins 3 work minutes after the unit is switched on
8. g 3000W 3000W 3500W 3500W Capacity Humidifying 0 2L H 0 2L H Capacity Moisture 50 L day 60 L day Removed Water Tank 2 4L 2 4L Capacity Refrigerant R410A R410A 330Wx477Dx630H 330Wx477Dx630H Net Weight 28KG 29 5KG 14
9. iginal position 9 6 Draining tube should be placed lower than the draining hole to allow the water to flow out effectively MAINTENANCE WARNING ALWAYS UNPLUG THE UNIT BEFORE MOVING OR CLEANING CLEANING Air filters The air filters are located on the left and right side of the unit To remove the air filters please follows the arrow directions below by pulling out the filters in an upward direction Clean only with warm soapy water Cabinet As with filters clean only with warm soapy water 10 CARE OF THE UNIT 1 Only plug the unit into a suitable 220 240V 50Hz AC 10 AMP power supply 2 Hold the plug when unplugging the unit never pull on the cord 3 Do not place the unit in direct sunlight This can fade the plastic case 4 Do not operate the unit in a confined space 5 Do not place objects on top of the unit This blocks the air outlet 6 Do not place the unit where the air inlets or outlets may be blocked by curtains or furniture 7 Keep the filters clean OVERHEAT PROTECTION This unit is fitted with an overheat prevention device If the unit overheats it will automatically turn off The unit can be restarted after 30 minutes ERROR CODES Error codes are shown on the display should a fault occur E1 Indicates open circuit or short circuit in the room temperature sensor E2 Indicates open circuit or short circuit in the pipe temperature sensor E3 Indicates a refrigerant leak Pl
10. matically after a set time period is complete 1 With the unit ON press the TIMER button to set the desired time for the unit to remain on 2 Once the set time period is complete the unit will turn off automatically If you press the POWER button before the time delay is complete the delay will be cancelled and the unit will turn off immediately Press the SLEEP button to select the sleep comfort mode When the unit is cooling and sleep mode is selected the unit will raise the set temperature 1 C each hour to a maximum of 2 C over two hours When the unit is heating and sleep mode is selected the unit will lower the set temperature 1 C each hour to a maximum of 2 C over two hours These temperatures will be maintained for the balance of the time set and help maximize sleep comfort When setting the sleep comfort mode please ensure that you set the number of hours required by using the TIMER function The hours set will be shown on the display by pressing either the TEMP or TEMP buttons REMOTE CONTROL FUNCTION a i 6 JOO 1 POWER On Off switch 2 FUNC Function MODE selector 3 TIMER Hourly programming 4 AUTO 9 Automatic fan speed 5 TURBO Turbo fan speed 6 amp High fan speed 7 LOW Low fan speed 8 SLEEP 0 Night operation selector 9 TEMP i Temperature selector INSTALLATION Unit Setup 1 Remove the water tank and take out the exh
11. protects the unit from possible damage due to rapid starting and stopping of its compressor Compressor operation begins 3 minutes after the unit is switched on or the mode is switched from dehumidify to air conditioning 2 FUNCTION Press this key to select cooling heating dehumidifying or humidifying Humidifier 1 The unit will stop automatically after four hours of operation Put water into the water filler 10 to restart operation 2 The unit will stop humidifying if the ambient humidity is equal to the pre set humidity 3 TEMP 4 TEMP In cooling mode this button raises the set temperature by 1 C each time it is pressed to a maximum of 30 C In heating mode this button raises the set temperature by 1 C each time it is pressed to a maximum of 25 C In cooling mode this button lowers the set temperature by 1 C each time it is pressed to a minimum of 17 C In heating function this button lowers the set temperature by 1 C each time it is pressed to a minimum of 15 C X The time taken to reach the desired set temperature will depend the environment and the size of the space in which the unit is operating in For example if the ambient temperature is too hot or the room is too large the rate at which the temperature descends will be slow as the cooling may be less effective 5 DISPLAY The display indicates the current set temperature or the timer setting When the timer or temperature is