Home

Software User Manual - SurgeX Energy Intelligence

image

Contents

1. ll Using the Software 1 Physical Connections a Plug the USB side of the Data Interface Cable into an available USB port b Plug the RJ 11 side of the Data Interface Cable into the RJ 11 OUT jack labeled Data Port on the enVision enabled unit which is the jack closest to the LCD c Note The enVision PCS must be powered by AC Mains for communications with the software to operate 2 Start the Software a Double click the desktop shortcut labeled enVison or use the ESP SurgeX enVision PCS Start Menu shortcut located at Se Start All Programs ESP SurgeX enVision PCS aisian 2014 Electronic Systems Protection Inc Technical Support 1 800 645 9721 espei com energy intelligence CSPG SURGEX envVisien S oftware User Manual 3 Configure the Data Interface Cable and COM Port a Click the COM Port Setup button labeled COM fan ESP SurgeX enVision PCS ri x 3 d Lee Ene ss ED 170 160 200 740 220 A E D gt H 5 10 15 20 25 30 E o D 400 BOO 1200 1600 2000 2400 2800 3200 TE D eve me Oo 04 D i 17 14 16 18 I Clear io Reset ou envisien ire a a t a b Click Configure i The auto configuration process will automatically set the correct device parameters of the Data Interface Cable to operate properly with the software and enVision e Note This process only needs to be done once for each new Data Interface Cable installed on the PC e
2. en B ESP SurgeX enVision PCS enVision E i AS FSP SurgeX enVision PCS enVision 2277 gt DNI RADAS IDDI DODAT RAADI AODAN DOREN KEDDI RAA z 119 21 v BE Gs One Shot D 40 SO 170 160 20 240 780 La f A Chi 100V Div 4 0 004 A es Over 0 5 10 15 20 AS 20 A cow WE ER ov v o 400 800 1200 1600 2000 2400 2800 3200 0 324 V Ch3 100W Div 4 0 1 2 3 4 5 6 7 8 9 10 l A UVrec 59 99 Hz E 59 bb Kn SH KK PI bi b7 h B4 BS Uvolf 0 878 PF o 0 2 0 4 oe 0 8 1 ro 1 410 CF WE 0 02 04 06 08 1 12 14 16 18 2 Clear wax 6ms Div el 0 0093 kWh Since 12 33 28 02 06 2014 Reset 0 17 5 0 0016 sno rgy intelligance envision Kc L Intelligence Software User Manual Software Version 1 0 O 2014 Electronic Systems Protection Inc TechnicalSupport 1 800 645 9721 espei com CSPG SURGEX envisi en S oftware User Manual energy intelligence NSTAL ANTON EE 2 1 COMPUTER REQUIREMENTS ccccececcececeececeeeecececeececeeaececeeaesecueaeaecueeaeceeeeaeeneaeaes 2 2 HARDWARE REQUIREMENTS ecececececececececececececececececucececucucucuseseceeeeeseeeseeeeeenenees 2 3 Download and Install Software rrorrrarnrnrnrnornvnnnrnenernrnnnenenenevernenenenenenennenenenenenenn 2 4 Install Data lntertaceCable occ cccccecececececeecececececaeaeaececeeueueavaeaeseneeneananas 3 USING THE SOFTWARE 8 nrrnenarnenarnannenannenannenarnenarnennrnennenennenennsnannsnennennrnannsnenne
3. ej Erase 08 49 71 09 19 20 D Average Power W 0 Maximum Power Draw W 118 43 Average Recorded Voltage VRMS 120 Maximum Recorded Voltage VRMS 117 Minimum Recorded Voltage VRMS 0 008 Maximum Recorded Current ARMS E 08 19 21 08 49 21 D Average Power A D Maximum Power Draw W 117 89 Average Recorded Voltage VRMS Average Voltage Graph 118 Maximum Recorded Voltage VRMS 116 Minimum Recorded Voltage VRMS Max Min Graph 0 008 Maximum Recorded Current ARMS re US Oust he CSP O SURGEX enVisien Import Historical Data energy nilelligensa Six electrical parameters are logged e Average Power Watts The average real power draw of connected equipment during the 30 minute recording interval Maximum Power Draw Watts The highest real power draw measured during the 30 minute recording interval Average Recorded Voltage Vrms The average line voltage during the 30 minute recording interval Maximum Recorded Voltage Vrms The highest line voltage measured during the 30 minute recording interval Minimum Recorded Voltage Vrms The lowest line voltage measured during the 30 minute recording interval Maximum Recorded Current Arms The highest current draw measured during the 30 minute recording interval After the historical electrical parameter data has been downloaded it may be saved to a file or graphically displayed by pressing one of the 3 Grap
4. Data AA ESP SurgeX enVision PCS enVision Erase Import Historical Data Erase WM envisien f Settings Mode i The Settings mode enables the specification of the user configurable parameters of enVision When this mode is entered it displays the parameters currently in use D ESP Sungex envision PES envio 02 06 14 16 03 32 d 150 Over Voltage Shutdown Set Clock Auto Set Clock 140 OI 135 Over Voltage Restore enVision 105 Under Voltage Restore Update ID 95 Under Voltage Record Update Limits Limits 280 d Under Voltage Shutdown Battery 100 2 99 ii Auto Set Clock ETE sets the internal clock to the current date and time iii Set Clock Sets the internal clock to a date and time manually specified in the date time field 2014 Electronic Systems Protection Inc Technical Support 1 800 645 9721 espei com 15 CSPG SURGEX enVisien Software User Manual energy intelligence iv Update ID Sets the product identifier specified in the text box 10 character limit v Update Limits Sets the 6 voltage thresholds specified by the voltage threshold selection fields Limit When Activated Action Over Voltage V gt OVshutdown Outlets turned Off and 150 280 Fvl Ma Jensen Over Voltage OVshutdown gt V gt OVrecord Outlets stay On and 145 270 eg TL dd Over Voltage V lt OVrestore After OVshutaown Outlets turned On and 140 260 seg Ice crew fe Under
5. Note This process edits Windows registry values and so may be blocked by MS Windows User Account Control UAC in Windows Vista 7 8 When using these operating systems it may be necessary to exit the software and restart it with administrative rights by right clicking the software shortcut and choosing Run As Administrator SZ ESP SurgeX enVision PCS gt al g espe Soap enVisien anergy intalligane 2014 Electronic Systems Protection Inc Technical Support 1 800 645 9721 espei com CSPG SURGEX enVislen Software User Manual energy intelligence c Click Detect i The auto detect process will automatically detect the COM Port number assigned to the Data Interface Cable li If the auto detection process is successful click Save The software is now properly configured and ready for use iii If the auto detection process is not successful verify that the Data Interface Cable device drivers are properly installed and that the physical connections between the enVision and the PC have been made correctly fay FSP SurgeX enVision PCS 3 3 Done Save enVisien 4 Software Modes The enVision Software is organized into several operational modes The modes are activated by clicking the corresponding button at the bottom of the software interface Press the Help Button in the upper right for additional information on the features available in the current mode Hovering the mouse cursor ov
6. Over Voltage Cutoff Line voltage exceeded the over voltage shutdown threshold and connected equipment was turned off Over Voltage Record Line voltage exceeded the over voltage record threshold and connected equipment was not turned off Under Voltage Record Line voltage dropped below the under voltage record threshold and connected equipment was not turned off Under Voltage Cutoff Line voltage dropped below the under voltage shutdown threshold and connected equipment was turned off Power Outage Loss of AC power Turn On The enVision outlets were turned on Turn Off Cycle A power cycle was initiated by a received command Turn Off Software Outlets were turned off by a received command Turn Off Button Outlets were turned off by the pushbuttons Turn Off Loss of Ground Outlets were turned off due to the loss of the safety ground conductor at the wall receptacle 2014 Electronic Systems Protection Inc Technical Support 1 800 645 9721 espei com 12 CSPG SURGEX energy intelligence envisien Software User Manual Historical Electrical Parameter Data Every 30 minutes enVision stores a snapshot of 6 electrical parameters measured over the prior 30 minute interval The internal memory can store 138 days of data Press the Import Historical Data button to download the data ay ESP Surgex enVision PCS enVision IS 28 2014 P 5 February Import Time Stamped Data
7. Voltage V gt UVrestore After UVshutdown Outlets turned On and 105 190 Peil kiss dl EI H Under Voltage UVshutdown lt V lt UVRecord Outlets stay On and 100 180 Ped ks rd sd TT Under Voltage V lt UVshutdown Outlets turned Off and 160 Fred sm Jesse g COM Port Setup Mode i The COM Port Setup mode is used to configure new Data Interface Cables for use Kl ESP Surgex enVision PCS 3 Detect Contigure Save CSPG SURGEX enVisien anergy intaliiganes li Detect Automatically detect the COM Port when the enVision Data Interface Cable and PC are properly connected and powered up lil Configure Automatically configure the advanced settings of the Data Interface Cable May require running the software with elevated permissions right click program shortcut and choose Run As Administrator on Windows Vista 7 8 with UAC User Account Control enabled iv Save Saves the COM Port selection 2014 Electronic Systems Protection Inc Technical Support 1 800 645 9721 espei com 16
8. aw Watts Neutral Ground Voltage AC RMS Volts Neutral Ground Line2 Ground Line Frequency Hertz Load Power Factor Line Voltage Crest Factor Energy Usage kWh of connected equipment since date and time of last manual usage reset 2014 Electronic Systems Protection Inc Technical Support 1 800 645 9721 espei com CSPG SURGEX enVisien energy intelligence Software User Manual d Outlet Control Mode i The Outlet Control Mode enables control of the AC outlets and provides information about wiring faults and abnormal line voltage GE oer enon RS en I Outlets are On Press to turn Off I Press to perform Power Cycle CSPG SURGEX envisien anergy intalliganes FREE SRR HIRE EFIT ESP SurgeX enVision PCS enVision Outlets are Off I No Ground Ba UL C CSPE SURGEX enVisien li Use the green On Off button to manually turn the AC outlets on and off e Pressing the blue Power Cycle button will result in the execution of a power cycle When commanded the outlets will turn off and then back on after a 90 second delay The Power Cycle indicator will be illuminated while a power cycle is active 2014 Electronic Systems Protection Inc Technical Support 1 800 645 9721 espei com 10 energy intelligence CSPS SURGEX enVisien Software User Manual e Historical Data Mode The Historical Data Mode allows for the retrieval and display of the power quality event and elec
9. er items will also display additional information Scope Mode Chart Mode and Historical Data Mode include a Save function Press the Save button to save data to a CSV file Time Stamped data may also be saved as a report in PDF format 2014 Electronic Systems Protection Inc Technical Support 1 800 645 9721 espei com CSPG SURGEX energy intelligence Software User Manual D Da DA D OE 1 13 LA LE LE pr Clear i dm L TREE z BBE a jas a Le S Reset au ESPG amp SURGEX enVision Fe eee ee ee E COM Port Setup Settings Historical Data kode Cutlet Control kode Chart Mode Scope Mode Multimeter Mode a Multimeter Mode i The Multimeter Mode provides information traditionally acquired from one or more handheld digital multimeters as well as an overview of the recorded power quality events and energy consumption of connected equipment 2 Measurement Accuracy fee FSP SurgeX enVision PCS enVision 1921 BE 0 40 a0 120 160 200 240 280 0 004 H 5 10 13 20 23 20 ov 0 400 800 1200 1600 2000 2400 2800 3200 0 324 V 0 1 H 3 4 5 6 7 8 9 10 59 99 Hz 5 Sb SF S 59 60 61 62 0 828 PF 1 410 CF 0 0093 kWh Since 12 33 38 02 06 2014 017 0 0016 PG zech enVisien 2014 Electronic Systems Protection Inc Technical Support 1 800 645 9721 espei com CSPG SURGEX energy intelligence envisisn Software User Manual li Real time display of 8 electrical paramete
10. h buttons 2014 Electronic Systems Protection Inc Technical Support 1 800 645 9721 espei com 13 CSPG SURGEX enVisien Software User Manual energy intelligence 1 Average Power Graph Pressing the Average Power Graph button will display a bar graph of the average real power draw of connected equipment during each 30 minute recording interval S i ESP Surgex envision PCS envision SHE 2 Import Time Stamped Data Average Voltage Graph Max Min Graph WM envision 2 Average Voltage Graph Pressing the Average Voltage Graph button will display a bar graph of the average line voltage during each 30 minute recording interval Ca gt B ee ESP Surgex envision PCS envision TE LL EEE EEE a AE EE JE 3 import Time Stamped Data Crase Import Historical Data Erase Average Power Graph Average Voltage Graph Max Min Graph CSRG suRGEX envision 2014 Electronic Systems Protection Inc Technical Support 1 800 645 9721 espei com 14 CSPG SURGEX enVisien Software User Manual energy intellige 3 Max Min Graph Pressing the Max Min Graph button will display line graphs of maximum voltage minimum voltage maximum current draw and maximum power draw during each 30 minute recording interval Pressing the V Max V Min I Max or P Max buttons will enable or disable the display of the corresponding parameter H Import Time Stamped
11. nennene 3 1 PYSICAL CONNECTIONS cccccecececececeececececeeeeaececececueaeaeaececuceeaeaeaesecueneeeaeaeaeetenentaeas 3 2 START THE SOFTWARE onnnnnannnnnnnnnnnnnnnnnnnnannnnnnennnnnnennnnenannnnnnannnnnnannnnnnannnnnnennnnnnennnne 3 3 CONFIGURE THE DATA CABLE AND COM bon 4 4 SOFTWARE MODES ve 5 a MULTIMETER Mon 6 See PENE 7 C CHART le 9 d OUTLET CONTROL Mont 10 e HISTORICAL DATA MODE EE 11 f GETTINGSMopnE 15 0 COM PORT EP Er 16 2014 Electronic Systems Protection Inc Technical Support 1 800 645 9721 espei com CSPG SURGEX enVisien Software User Manual Il Installation 1 Computer Requirements a Minimum 133MHz Pentium processor or equivalent minimum 64MB of RAM minimum 10MB free hard drive space VGA or higher resolution monitor keyboard mouse CD or DVD drive minimum screen resolution of 1024x768 Microsoft Windows XP Vista 7 8 2 Hardware Requirements a For use with enVision enabled products and Data Interface Cable XG PCS 1C 1 3 Download and Install Software a Download the Software Installer from www espei com b Unzip and run the installation utility c Follow the on screen instructions to complete installation of the software o ESP SurgeX enVision PCS Setu e Options Selectthe options you want and click Nextto continue Please select from the following options Launch ESP SurgeX enVision PCS C Install Interface Cable Driver Note You may select as many op
12. pressing the Wait button will freeze the currently displayed waveform vi One Shot Trigger Function e The scope may be set to acquire and hold a waveform display triggered by either Voltage or Current level e Press the One Shot button above the desired channel A trigger level cursor will appear on the display e Next Drag the trigger level cursor to the desired amplitude and press the Wait button Ch1 100V Div p A bi dl i Cha 100W Div 4 6 ms Div aj OSP mech enVisien ser e Ifthe Voltage of Current exceeds the trigger level the scope will hold the display as ESP SurgeX enVision PCS enVision WS H One Shot Chi 100V Div A h Ch3 100W Div Y Wait 888 CH tT 6 ms Div MP CSP SURGEX enVision 2014 Electronic Systems Protection Inc Technical Support 1 800 645 9721 espei com CSPG SURGEX energy intelligence c Chart Mode enVisien Software User Manual i The Chart Mode enables a chart style data logging function of 8 electrical parameters Data point measurements are acquired once per second The measured parameters may be enabled or disabled by pressing the corresponding button ae ESP SurgeX enVision PCS enVision l TL CS RES ee CSPG SURGEX enVisien li Chart display of 8 electrical parameters Line Voltage AC RMS Volts Line Neutral Line1 Line2 Load Current Draw AC RMS Amps Load Power Dr
13. rs Line Voltage AC RMS Volts Line Neutral Line1 Line2 Load Current Draw AC RMS Amps Load Power Draw Watts Neutral Ground Voltage AC RMS Volts Neutral Ground Line2 Ground Line Frequency Hertz Load Power Factor Line Voltage Crest Factor Energy Usage kWh of connected equipment since date and time of last manual usage reset iii Number of recorded power quality events b Scope Mode Surge Events SG Overvoltage Events with turn off of connected equipment OV off Overvoltage Events with no turn off of connected equipment OVrec Undervoltage Events with no turn off of connected equipment UVrec Undervoltage Events with turn off of connected equipment UV off Power Outage Events PO i The Scope Mode enables a real time voltage current and power oscilloscope which incorporates many functions available in standalone oscilloscopes 4kHz Oscilloscope Bandwidth li Ch1 Ch3 buttons toggle waveform displays Ch1 button toggles line voltage trace Ch2 button toggles load current trace Ch3 button toggles load power trace 6 ms Div EI m enVision 2014 Electronic Systems Protection Inc Technical Support 1 800 645 9721 espei com eSP SURGEX enVisien Software User Manual energy intelligence ii Up A and Down V Arrow buttons adjust the vertical axis scaling of each channel iv Left lt and Right gt Arrow buttons adjust the horizontal time axis scaling v While in normal operation
14. tions as you want 2014 Electronic Systems Protection Inc Technical Support 1 800 645 9721 espei com CSPG SURGEX enVisien Software User Manual energy intelligence 4 Install Data Interface Cable a Automatic Installation Requires Internet connection i Plug the USB side of the Data Interface Cable into an available USB port li Windows will automatically detect and install appropriate device driver files for the Data Interface Cable e Ifa Found New Hardware pop up box appears follow the on screen instructions and allow Windows to search online for driver files e The installation could take several minutes to search for and download appropriate driver files Once the files are found follow the on screen instructions to install e Note The driver installation process will first install USB Serial Converter driver files and then will install USB Serial Port drivers separately b Manual Installation In the event that the automatic driver installation process was not successful or if no internet connection is available the Data Interface Cable driver files may be installed manually e Select Install Drivers during the Software Installation process e Orrun enVision PCS Interface Setup from Start All Programs ESP SurgeX ESP enVision PCS c Once the Data Interface Cable has been successfully installed it will appear in Device Manager as USB Serial Port COMx under Ports COM amp LPT
15. trical parameter data stored in the enVision internal memory a ESP SurgeX enVision PCS enVision l OX 5 Import Time Stamped Data Erase Import Historical Data Erant B Uk OL BE CSPG SURGES enVisien ry brite di qance i Time Stamped Power Quality Event Data e enVision is able to store and timestamp the 512 most recent power quality events in its internal memory Press the Import Time Stamped Data button to download the event data 12 46 45 Surge 10 46 22 Turn On AS ESP SurgeX enVision PCS enVision EE 2014 z Z E January 30 2 16 34 50 Power Outage 16 34 47 Surge 16 34 41 Turn On 16 32 51 Power Outage 16 32 51 Turn Off Loss of Ground ee a oe re 2013 288 CSPG SURGEXN enVisien preses iganee ETTE O 2014 Electronic Systems Protection Inc TechnicalSupport 1 800 645 9721 espei com 11 CSPG SURGEX energy intelligence enVisien Software User Manual e Twelve types of events are logged Overload Load current draw has exceeded 25A Surge enVision has been exposed to a transient voltage in one of the 3 possible modes between Live and Neutral between Live and Ground between Neutral and Ground with a peak amplitude of 500V or higher and a frequency of 20 kHz or higher 500V surge voltage amplitude applies to IEEE C62 41 Category B Impulse surge voltage amplitudes necessary for detection of other surge types may vary