1. OFF OFF 4 8 port set as common straight through connection mode 1 2 pot set as common straight through connection mode WT 4 8 port set as set as redundant mode remote 1 2 pot set as common straight through connection mode m l ON 4 8 port set as set as set as redundant mode remote 1 2 port set as set as redundant mode local 1 DIP switch for property setting 4 8 port set as redundant mode local 1 2 port set as redundant mode local The DIP switch for setting of KIEN5000 has two positions namely T and F The corresponding relation between specific positions of DIP switch and equipment setting is shown in Table 3 2 A Attention In a redundant ring network only one end equipment should be set as local and others as remote 3 2 4 Bottom panel There is a threaded hole for grounding in the bottom panel of KIEN5000 M3 X8 screw and 3 cold pressed terminal for grounding free of charge will be delivered together with the main unit As shown in Figure 3 8 crimp one end of grounding conductor to the cold pressed terminal and then use the grounding screw to fix it at the grounding hole of the shell reliably connect the other end of grounding conductor to the ground The diameter of grounding cable should be less than 2mm 15 Cold Pressing Terminal Gr
2. Output Terminal of the Wrni ng Rel ay Power Input 2 Power Input 1 epa Ul pPo PG Arn ME P2 P1 CONSOLE Input 18 36VDC T AF ON 3 Attri bute oe Setting Swtch ministration Interface Figure 3 4 Top panel structure diagram Power input terminal KTEN5000 has redundant power input function It has two power input terminals P1 and P2 each allowed to be used singly or both to be used simultaneously to input power to KIEN5000 from two independent sets of external DC power supply systems so that when either of the two sets of power supply systems fails the equipment can operate uninterruptedly thereby increasing the reliability of network operation Three wire terminal with interval of 3 81 mm is used for power connection The diameter of power cable is less than 1 5 mm Connection sequence is shown in Figure 3 5 Connection and mounting procedures are as follows 12 13 1 Strip 5mm long sheath from power cable and twist the bare copper wires together into a bundle 2 Use a 2 5 mm one slot screwdriver to unscrew the power cable locking screw insert the power cable into the hole at the terminal tail and screw down the power cable locking screw 3 Insert the power terminal into the DC power socket of the equipment and use a 2 5mm one slot screwdriver to screw down the two
3. two kinds of mode One is straight through connection mode act as normal Ethernet interface another one is redundant ring mode and supports twisted pair redundancy technology with recovery time less than 300ms 3 Inline with meeting IEEE802 3 802 3U 802 3X 4 Meanings of RJ45 port indicator yellow lamp speed indicator on 100M off 10M Green lamp connection state indicator on effective connection of network off no connection 6 2 3 Service function Configuration and Management At KIEN5000 the settings queries and management can be realized for the whole switch or network system through CONSOLE interface Telnet and Web browner LED Indicator The LEDs indicate the port status correctly including transmission rate link status and system status VLAN The network can be divided into several VLANs according to ports through which the users in one VLAN can communicate each other The VLAN of KIEN5000 conforms to IEEE802 1Q and can realize the communication within one VLAN of different switches KIEN5000 supports up to 4094 VLANs based on IEEE802 1Q 802 1p Prioritization KIEN5000 conforms to 802 1p which is used the most widely in LAN environment The end users of KIEN5000 can make use of this function to configure the port based prioritization when 802 1p is not supported at user s end and different priority is necessary for different ports services Only the data package without Prioritization in
4. CTL C command after the operation is over 10 minutes this indicates that the operation is normal Chapter 6 Networking Mode and System Configuration 6 1 Networking mode KIENS5000 Industrial Ethernet Switch has 4 10Base T 100Base TX RJ45 Ethernet ports each can provide special link to directly connect end equipment or connect another industrial Ethernet switch or hub as a common link KIEN5000 Industrial Ethernet Switch also has 4 100Base T 100Base TX Ethernet RJ45 interfaces of uplink redundancy By using the uplink redundancy RJ45 interface a twisted pair redundant ring network can be formed The recovery time of the ring network redundancy is less than 300ms when the system is in fault It is widely applied in many fields such as electric power transportation energy water treatment automatic control of large factory and office scheduling etc The most typical network forming mode of KIENS5000 is redundant ring network and redundant double ring netowrk KIEN5000 can form a twisted pair redundant ring network as shown in Figure 6 1 in which one end unit is set as local one and the others as remote one When a twisted pair disconnection happens at any place communication can be resumed within 300ms Figure 6 1 twisted pair redundant ring network composed by KIEN5000 Double ring redundancy twisted pair network can be done in KIEN 5000 shows in Figure 6 2 When a twisted pair disconnection happens at any place communication
5. be equipped at both ends of the cable A Warning Don t insert a telephone plug into any RJ 45 port Only use twisted pair with RJ45 connectors at both ends conforming to FCC standard Fig A 1 Shows how the connector of RJ 45 is numbered please make sure that the inserting direction is correct Figure A 1 Connector of RJ 45 Pin distribution of 10Base T 100Base TX Unshielded twisted pair UTP or shielded twisted pair STP will be used for the connection of RJ 45 for the connection of 10Mbps category 3 4 and 5 of 100 ohm will be used and cat 5 of 100 ohm will be used for 100Mbps Additionally do make sure that the connecting length of any twisted pair shall not exceed 100 meter Port of RJ 45 supports automatic MDI MDI X operation PC or server may be connected with straight through cable or connect with other switch or hub In straight through cable pin 1 2 3 and 6 at one end of the cable are connected to pin 1 2 3 and 6 at the other end of the straight through cable respectively Cross over cable should be used for switch or hub with MDI X port The pin distribution of 10Base T 100Base TX is listed in the table A 1 Table A 1 Pin distribution of 10Base T 100Base TX Pin MDI X signal name MDI signal name Receiving data RD Output data TD Receiving data RD Output data TD Output data TD Receiving data RD L s Output data TD Receiving data RD 4 5 7 8 Un
6. er sunk Flat head Screws Figure 4 4 Mounting wall mounting plate 3 Select mounting position vertical wall or inner wall of cabinet If you select to mount on vertical wall you are recommended to use 96 plastic expansion bolts and tapping screws for equipment mounting According to the mounting dimensions marked in Figure 4 3 drill four 6 holes with an impact drill on the wall the depth of the holes should allow fully inserting the plastic expansion bolt fully insert the plastic expansion bolts in the holes on the wall screw down the tapping screws into the plastic expansion bolts with a cross head screwdriver but do not screw down thoroughly reserve a distance of around 5 mm if you select to mount on the inner wall of cabinet you are recommended to prepare four M3 threaded holes on the inner wall of cabinet when making the cabinet according to the mounting dimensions marked in Figure 4 3 or drill four 4 holes with a hand held electric drill on site and screw down four M3 X10 pan head screws with cross recess into the four holes with a cross head screwdriver if the holes are not threaded inside it is necessary to mount four M3 nuts on the back side Do not screw down the screws thoroughly reserve a distance of around 5 mm 4 After fastening the screws on the wall mount KIEN5000 in the selected position Pass the four screws through the four 65 holes on the wall mounting pl
7. the high temperature resistance of equipment Discarding the traditional form of axial fan heat dispersion reduces power consumption of the entire unit and increases the stability of the system The figuration of KIEN5000 case is shown in Figure 3 2 8 9 Its contour dimension excluding the dimensions of DIN rail and wall mounting components is 142 mmx55 4 mmx120 5 mm heightxwidth xthickness 142mm Figure 3 2 Outline drawing of KIEN5000 A Warning The shell of this switch is a part of the heat dissipation system of the unit It may get hot during working so never touch the shell when the equipment is working to avoid burning 3 2 2 Front panel The front panel of KIEN5000 industrial Ethernet switch has integrated four 10Base T 100Base TX RJ45 Ethernet ports and four system and port operation indicators Its structure is shown in Figure 3 3 POWER1 PO R2 I ndi cator for Pow Syst em Qper at i ng RUN St at us 4 KIEN Industrial Ethernet Switch 8 ndi cator for lt 7 n Port
8. 0 industrial Ethernet switch e Appendix C introduces abbreviations used in this manful Statement as product and technology upgrades and improves constantly the contents of this document may not completely accord with the actual product For product upgrading information please access our company s website or directly contact with our company s business representative Notice for Safety Operation This product offers reliable performances as long as it is used within the designed scope Artificial damage or destruction of the equipment should be avoided e Carefully read this manual and well preserve this manual for future reference Do not place the equipments near water sources or damp places Do not place anything on power cable which should be placed in unreachable places Do not tie or wrap the cable to prevent fire Power connectors and connectors for other equipments should be firmly interconnected and frequently checked In the following cases please immediately disconnect the power supply and contact with our company 1 Water gets into the equipments 2 Equipment damage or shell breakage 3 Abnormal operation conditions of equipment or the demonstrated performances have changed 4 The equipment emits odor smoke or noise Please keep optical fiber plugs and sockets clean During operation of equipments do not stare directly into the cross section of optical fiber Please keep the equipme
9. 30V MX Power Ground Figure 3 6 External alarming lamp of alarming relay output Network management interface CONSOLE The network management interface of KIEN5000 is shielded RJ45 connector and its interface communication standard is 3 wire RS232 Users can the network management cable with end bearing RJ plug and another end DB9F plug to connect the network management interface of KIEN5000 with the 9 pin serial port of the control computer Operating the local management software provided by KYLAND Telecom in the control computer allows configuration enquiry and management of the KIEN5000 equipment directly connected with the serial port of the control computer Connection of network management cable with the local terminal network management interface to operate the network management software provided by KYLAND Telecom in the control computer allows to realize the configuration enquiry and management functions of all KIEN5000 equipments within the entire network The wiring sequence for network management interface of KIEN5000 and the 9 pin serial port of PC computer is shown in Figure 3 7 PC 9 pin Serial Port KI E5000 CONSCLE SS Figure 3 7 KIEN5000 network management wiring diagram Table 3 2 Corresponding Relations between Specific Positions of DIP Switch and 14 Equipment Attribute Position of DIP Switch Position Sketch Logic position Attribute Implication WT i
10. KIEN5000 Industrial Ethernet S witch User s Manual KYLAND Telecom Technology Co Ltd KIEN5000 Industrial Ethernet Switch User s Manual Copyright 2005 KYLAND Telecom Technology Co Ltd All rights reserved No part of this documentation may be excerpted reproduced translated annotated or duplicated in any form or by any means without the prior written permission of KYLAND Corporation Publisher KYLAND Telecom Technology CO LTD Address 5 F Office Building Transport Center East of Xisanqi Bridge Haidian District Beijing China Website http www kyland com cn Postcode 100096 Tel 86 10 82900770 Fax 86 10 82900780 E mail marketing kyland com cn Version V1 Dec 2005 No e6t02050701 Preface KIEN5000 is a high performance network managed industrial Ethernet switch specially designed by KYLAND Telecom Technology CO LTD for industrial applications Its high performance switch engine solid and closed case design high efficient single rib shape case heat dispersion surface without fans overcurrent overvoltage and EMC protection at power input side and excellent EMC protection of RJ45 port allows KIEN5000 applicable in harsh and dangerous industrial environments The redundant function of optical fiber network independent entire network management channel redundant power input function and powerful entire network real time management system provides multiplex guarantee for reliable op
11. Speed 2 3 5 F H 10M 100M Indicator for Port Connecti on St at us Figure 3 3 Front panel diagram Uplink redundant Ethernet RJ45 port KIEN5000 has four uplink redundant 100Base T 100Base TX interface with port number of 2 and 4 8 1 and 2 are a pair 4 and 8 are a pair In the event of the system fault the recovery time of the redundant ring network is less than 300ms effectively enhancing the reliability of network operation Ethernet RJ45 port 10 KIEN5000 has four 10Base T 100Base TX RJ45 Ethernet ports numbering 3 5 6 7 Each RJ45 port has self adaptation function Straight through cable cross over cable can be used to connect the switch with end equipments servers hubs or other switches Each port supports IEEE802 3x self adaptation so the most suitable transmission mode half duplex or full duplex and data rate 10 Mbps or 100Mbps will be automatically selected the connected equipment should also support this characteristic If the equipment connected to these port does not support self adaptation the ports will send proper speed but the default transmission mode is half duplex LED indicator The indicators on the front panel of KIEN5000 can indicate system operation and port status helping detect and eliminate faults Table 3 1 describes the meanings of all indication lamps on the front panel Table 3 1 LED Indicator Descriptions 1 2 port and 4 8 port RUN st
12. antities of all cables comply with the construction drawing design and contract requirements Before cable wiring it is necessary to check whether there is damaged cable and whether the cables are accompanied by ex factory records and vouchers attesting their quality such as quality assurance certificate etc The specifications quantities route directions and laying position of the cables to be laid should meet the design requirements of construction drawings The laying length of each cable should be determined according to its actual position No intermediate break or joint is allowed for the cables to be laid User s cables and power cable should be laid separately Inside walkways the cables should be properly arranged in good order with uniform smooth and flat turnings Cables should be straightly laid in cable channels Extruding of cable from cable channels to block other outlet or inlet holes is not allowed The cables at the outlet part of cable channel or at turnings should be bundled and fixed If cables power line and grounding conductor are laid in the same channel cables power line and grounding conductor should be not folded or blended together If a cable line is overly long coil and place it in the middle of the cabling rack do not let it cover on other cables There must be the relevant marks at both ends of cable and the information on the marks should be explicit to facilitate ma
13. ate LED The 4 8 interface of the switch is set as redundant mode n the unit is set as central office devices The 4 8 interface of the switch is set as redundant mode and 4 8 port Blinking RUN the unit is set as remote The optical fiber interface of the switch is set as common OFF direction connection mode The 1 2 interface of the switch is set as redundant mode and the unit is set as central office devices The 1 2 interface of the switch is set as redundant mode and Blinking the unit is set as remote The optical fiber interface of the switch is set as common direction connection mode Power LED POWER 1 POWER 2 Ethernet RJ45 port state LED 11 Each RJ45 Ethernet port has two indicators a yellow lamp and a green lamp The yellow lamp indicates port speed and the green lamp indicates port link state 10M 100M On 100M working status i e 100Base TX Yellow lamp 10M working status i e lOBase T LINK ACT Effective network connection has been established for the green Blinking Network activities are available at the port No effective network connection has been established for the lamp Off port 3 2 3 Top panel The top panel of KIEN5000 industrial Ethernet has integrates two power input terminals for redundant power supply alarming relay output terminal RS232 management port DIP switch for switch attribute setting etc
14. ate and slip KIEN5000 downwards as shown in Figure 4 5 Fasten the four screws KIEN5000 has now been fastened on the wall or inner wall of cabinet E Ea pac 5 5 pac 7 LNWACT OU Lj 10M 100M 7 a O Coa Ds LNKJACT Figure 4 5 Schematic diagram for wall mounting process 4 3 Cable connection After properly mounting KIEN5000 it is ready for cable mounting and connection mainly including cable connection for the following interfaces 1 Service interface 22 4 4 Cable wiring 23 KIEN5000 provides 10Base T 100Base TX RJ45 Ethernet interface for the connection to end equipments in straight through way and to network equipments in cross over way Network management interface connection KIEN5000 is connected with the serial port of control computer via the CONSOLE port of the top panel Users can make a network management line with proper length according to Figure 3 7 Power connection Use 24V DC power supply for KIEN5000 equipment according to the indications on product label Connect power supply after finishing connection of all other cables Cable wiring should meet the following requirements 1 Before cable wiring check whether the specifications models and qu
15. can be re configured within 300ms 26 c Twisted pair Redundant Ring 1 Figure 6 2 twisted pair redundant double ring network composed by KIEN5000 A Attention When KIEN5000 is forming a redundant ring network connection of electrical port 4 and 8 are recommended namely the electrical port 4 of one end equipment shall be connected with the electrical port 8 of the other end equipment This is shown as the following figure ALLE Port4 Port Por t4 Port 8 Port4 Port 8 Port 4 Port 8 KIEN5000 KIEN5000 KIEN5000 KIEN5000 6 2 System configuration 27 KIEN5000 Industrial Ethernet Switch is an integrated structure the 4 10Base T 100Base TX Ethernet RJ 45 ports and 4 uplink redundant 10Base T 100Base TX RJ45 interfaces are fixed configuration The power supply voltage is DC 24V The specific configuration and its corresponding models are shown as Table 6 1 Table 6 1 Configuration table of KIEN5000 Product Model Product Description 4 10Base T 100Base TX RJ45 interface and 4 uplink redundant 10Base T 100Base TX RJ45 interface KIEN5000 8T 28 29 Appendix A Twisted pair and Pin Distribution For the connection of 10Base T 100Base TX the twisted pair must have two pair cable Each pair is distinguished with two different colors For example one strand is green and the other is the alternate of green and white stripes RJ 45 connector should
16. dads seeds e P ORE TRUE GEO E oped Sa asa Ts 8 3 22 Front panel ee ten ot uten ott eH aaepe RR 10 3 2 3 Top panel nne on ReU CRUDO ned a E DOPO 12 32 4 Bottom panel iti eee Ree ertet reo eere tres Pott eet eate isu hes detent 15 Chapter 4 Hardware Mounting eee e eese eese esent tenen so en sesenta suse tassa sss non ace corso 17 4 1 Mounting requirements scorre XR CREER UE REY pee 17 4 2 inguine PET 17 42 1 Rail MOUNUNE a ee erbe EU ES ries O PT evga Eee eet Id 17 4 2 2 Wal mounting aa ua apas is 19 4 3 Cable connection a Aa h a A a te tle eee oe rre 22 23 Chapter 5 Testing Method ccsscsscscscsscssssssscsssccsccsecssscssssssscssssscsssssscesceseesessssssesseeseceseesessssssessesscses 24 Dal Self testing process eos Ree IRURE RR UE 24 5 2 Testing of Ethernet interface osete Ea aE E eee eE e a a naq S trennen enne 24 5 3 Testing of uplink electrical ports nennen ener entente nente etre 24 Chapter 6 Networking Mode and System Configuration 26 6 1 Networking mode iia noir 26 62 System confi rurat ON td 27 Appendix Twisted pair and Pin Distribution 29 Appendix Cable Type and S
17. direction of the packing case and ensure its right side is facing upward so as to prevent KIEN5000 from falling apart after opening the case If a hard object is used to unclench the case do not overly extend the hard object into the case to avoid damage of the equipments inside the case After opening the case check the amount of KIEN5000 equipments including main unit of KIEN5000 parts of equipment user s manual customer service guideline according to the packing list and check the appearance quality of KIEN5000 A Warning For the built in precise parts of equipments please handle with care and avoid strenuous vibration to avoid affecting the performances of equipments Chapter 2 Performance Indexes 2 1 System indexes 5 The system performance indexes of KIEN5000 industrial Ethernet switch are shown in Table 2 1 Table 2 1 System Indexes System Indexes KIEN5000 Quantity of RJ45 port 4 x10Base T 100Base TX Quantity of uplink redundant RJ45 port 4 x10Base T 100Base TX System parameters Supporting standard IEEE802 3 IEEE 802 3x IEEE 802 3u IEEE 802 1p IEEE 802 1Q Store and Forward speed 148810 pps Max filtering speed 148810 pps Switching mode Store and Forward Switching bandwidth of system 5 6G MAC address list 8k Max VLAN quantity 4094 Electromagnetic compatibility interference EN55022 Electromagnetic compatibility immunity EN50082 2 Ethernet
18. e 4 2 Mounting KIEN5000 on DIN rail 4 2 2 Wall mounting 19 In some places wall mounting may be more suitable than DIN rail mounting KYLAND Telecom can provide the component wall mounting plate for mounting KIEN5000 on wall Wall mounting dimensions are shown in Figure 4 3 KIEN Industrial Ethernet Switch 1 5 10 100 7 LNK ACT Figure 4 3 KIEN5000 wall mounting dimensions A Attention Wall mounting plate is not included in standard configuration of KIEN5000 It should be ordered independently when ordering Wall mounting procedures for KIEN5000 1 Use a cross screwdriver to unscrew the two screws fastening the DIN rail connector socket on KIEN5000 equipment and remove the green DIN rail connector socket 2 Take out the wall mounting plate and the screws cross recessed 20 countersunk head screws M3 x6 for mounting wall mounting plate from the packing box Use a cross head screwdriver to mount the wall mounting plate in the position originally for mounting DIN rail connector socket The mounting direction of the wall mounting plate is shown in Figure 4 4 Val Hangi ng Pl ate Count
19. eration of the system The User s Manual for KIEN5000 Industrial Ethernet Switch mainly introduces the information technical principles performance indexes installation and commissioning network management etc to provide users with references in startup expansion and routine maintenance It is a practical teaching material that can be used by users in trainings and helps the relevant technical personnel to increase their knowledge and understanding of KIEN5000 industrial Ethernet switch This manual mainly includes the following contents e Chapter 1 introduces general description and system features of KIEN5000 industrial Ethernet switch e Chapter 2 introduces performance indexes and service functions of KIEN5000 industrial Ethernet switch e Chapter 3 introduces hardware structure of KIEN5000 industrial Ethernet switch e Chapter 4 introduces mounting process of KIEN5000 industrial Ethernet switch e Chapter 5 introduces network management of KIEN5000 industrial Ethernet switch e Chapter 6 introduces local management of KIEN5000 industrial Ethernet switch e Chapter 7 introduces field test methods for KIEN5000 industrial Ethernet switch e Chapter 8 introduces network forming modes and system configuration of KIEN5000 industrial Ethernet switch e Appendix A introduces twisted pair and pin distribution rules of KIEN5000 industrial Ethernet switch e Appendix B introduces cable types and specifications of KIEN500
20. et is 100Mbps bit per second It expresses the signaling rate which is defined as the change times of the Baud Rate MM P status for the electric or optical transmission medium within 1 second One of network equipments which run on the layer2 in the OSI layer7 model and it can be connected to the LAN or network segment which uses the same protocol It presents the automatic network address learning and network configuration function It is a congestion control mechanism The network equipment sends the data to the equipment which has overloaded and causes the port to congest Traffic Control The traffic control can prevent the data packet from loss and avoid the congestion for the port It is the Virtual Local Area Network which means that it takes the network management software to establish the point to point logic vom network which can cross different network segment and various network on the switching LAN One data packet is sent to all equipments on the network Restless forward broadcast frame or multicast frame on bridge caused by Broadcast storm the bridge ring Use switches to set up the point to point connection among nodes in the Full Duplex LAN and allow them to receive and send data packet at the same time The communication for two nodes can only move toward one direction at Half Duplex the same time but can not move toward both directions It is the Medium Dependent Inte
21. intenance Chapter 5 Testing Method 5 1 Self testing process As soon as the equipment is powered all the indicator of service ports at the front panel will blink once at the moment this indicates the operation of the ports is normal after this the corresponding POW will keep the light on the RUN lamp operation lamp will keep on light blink be off according to the attribute of attribute switch setting 5 2 Testing of Ethernet interface Power KIEN5000 as shown in Fig 5 1 make any two Ethernet interfaces connect with the network port of the two testing computers by straight through network cable transmit Ping command mutually both sides can correctly Ping to each other and no data package is lost At the same time the yellow lamp on the corresponding port should keep on computer network interface card operates in 100M state or keep off computer network card operates in 10M state and the green lamp on the corresponding port should flash This indicates the tested hardware of the two electrical operates normally The same testing method will be used to test all the rest Ethernet interfaces For detailed operation of the Ping command please refer to the following examples Testing Computer 2 Fig 5 1 Testing of Ethernet port 5 3 Testing of uplink electrical ports Let the equipment of KIEN5000 at both ends to form a fiber link network as 24 shown in Fig 5 2 connect any one Ethernet i
22. nctions can be configured functionally The alarming information is shown on management interface Chapter 3 Hardware Structure 3 1 System structure The hardware structure of KIEN5000 industrial Ethernet switch is shown in Figure 3 1 Switching gt Network Controller x T I Power Port EMC protections Hectric Hectric Electric Ports IK Port 4 Port 8 1 23567 Figure 3 1 Hardware structure The system hardware mainly consists of 1 The switch controller uses high performance ASIC chip technology and provides two layer linear speed forwarding of data packet 2 Industrial power supply with overcurrent overvoltage and EMC protection is used as the power supply 3 EMC protection is provided for all electrical interfaces and CONSOLE interface 3 2 Switch Structure 3 2 1 Case KTENS5000 case is a small DIN rail or wall mounting type structure The entire unit has a six side enclosed structure with protection class up to IP30 The case s left and right side plates made of ribbed aluminum profile are a part of the heat dispersion system of the entire unit The single rib structure can double heat dissipation area The heat generated when the unit is working is effectively dissipated into the environment via the ribbed heat dissipation surface in the form of radiation and convection greatly increasing
23. nt clean if necessary wipe the equipment with soft cotton cloth Do not repair the equipment by yourself unless it is clearly specified in the manual Explanation of Warning Marks This manual uses two kinds of noticeable warning signs to arouse special attention of users during operation The implications of these signs are as follows Warning pay special attention to the notes behind the mark N improper operation will result in serious damage of the switch or injury of operation personnel Caution attention warning danger remind the positions requiring attention during operation Contents Chapter 1 System Overview cccsscscsscssessesssscscssccssceseessscsscscsscsecsscescssssscsseeseessesescsessesssesseesecsesssesseses 2 Ll Product Overview eei etre RO EBD eH ee nen B gr ee 2 1 2 Features edet la 2 1 3 Packing list and unpacking check i ss a Ghee aaa asa Ae NAMA n etii ES 3 Chapter 2 Performance Indexes 5 21 System INGER EG EPOR 5 psal Mtra is 6 MESS TUNCHOD ET ERROR RE TUR T RR PR eee HR ders 7 Chapter 3 Hardware Structure ee e pk 8 3 System SUCIA tee serie ere in ib 8 IZ WIECB SEEUCLUES na eere ee Ple lever epit ert eset deret td eere ea 8 By ZAC ASC
24. nterface of each equipment to the testing computer by straight through network cable transmit Ping command mutually both sides can correctly Ping to each other and no data package is lost This indicates the tested hardware of the two electrical operates normally The same testing method will be used to test the other pair of uplink electrical ports For detailed operation of the Ping command please refer to the following examples ETEN5000 Testing Computer 1 Testing Computer 2 Figure 5 2 Uplink Electrical port testing Example of PING command The IP address of testing computer 1 is 192 168 100 10 and that of the testing computer 2 is 192 168 100 11 operating command in the Operation column of the Starting menu of the operating testing computer 1 is cmd or command WIN2000 system uses cmd WIN98 95 uses command respectively transmitting ping is 192 168 100 11 1 1000 t 1 refers to the number of byte t means continuously transmitting data operating command in the Operation column of the Starting menu of the operating testing computer 2 is cmd or command WIN2000 system uses cmd WIN98 95 uses command respectively transmitting ping is 192 168 100 10 1 1000 t testing computer 1 replies from 192 168 100 11 bytes 1000 time lt 10ms TTL 128 testing computer 2 replies from 192 168 100 10 bytes 1000 time lt 10ms TTL 128 If the lost package rate is 0 based on the statistic by using
25. ound Screw Ground Wire Figure 3 8 Grounding methods for KIEN5000 case 16 Chapter 4 Hardware Mounting 4 1 Mounting requirements KIENS5000 industrial Ethernet switch has a single body structure and can be directly mounted on standard 35 mm DIN rail or vertically mounted on the wall or inner wall of cabinet with wall mounting components Before mounting KIEN5000 first check whether the working environment meets the mounting requirements including power supply requirement adequate space the distance to other network equipments to be connected and whether other equipments are available Please ensure that the following mounting requirements are met 1 Power supply requirement standard KIEN5000 product uses redundant 24VDC power supply 18VDC 36VDC 2 Environment requirement temperature 35 C 75 C relative humidity 10 95 non condensable 3 Grounding resistance requirement 5 4 Check whether cable is laid properly 5 Avoid exposure to exposure to direct sunlight and keep away from heat source or places with strong electromagnetic interference 6 Standard KIEN5000 product only provides DIN rail mounting components so users only need to get DIN rail available If wall mounting is necessary users need to purchase additional wall mounting components Moreover users should also get available screws nuts and tools for wall mounting and ensure the mounting is reliable 7 Check whe
26. pecifications 32 Appendix C GIOSSALY d 33 Chapter 1 System Overview 1 1 Product Overview KIENS000 is a high performance managed industrial Ethernet switch specially designed by KYLAND Telecom Technology CO LTD for industrial applications Its high performance exchange engine solid and closed case design high efficient single rib shape case heat dispersion surface without fans overcurrent overvoltage and EMC protection at power input side and excellent EMC protection of RJ45 port allows KIEN5000 applicable in harsh and dangerous industrial environments The redundant function of optical fiber network independent full network management channel redundant power input function and powerful full network real time management system provides multiplex guarantee for reliable operation of the system KIENS5000 industrial Ethernet switch provides two mounting ways DIN rail and wall mounting On the front panel there are four uplink redundant 10Base T 100Base TX RJ45 interface In the event of system failure the recovery time of the redundant ring network will be less than 300ms It provides four 10Base T 100Base TX RJ45 ports Each RJ45 port has adaptive function capable of automatically configuring to 10Base T or 100Base TX status and full duplex or half duplex operation mode 1 2 Features High performance Indus
27. port Physical port shielded RJ 45 RJ 45 port 10Base T 100Base TX supporting automatic negotiation function Port standard in line with IEEE802 3 standard Transmission distance 100m CONSOLE interface Physical interface shielded RJ 45 Interface standard in line with RS232 standard 3 lines Interface speed 9600bps Power supply Input voltage double channeIDC24V DC 18V 36V Input power consumption lt 6W Overcurrent protection built in Mechanical parameter Physical dimensions heightxwidthxdepth 142 mmx55 4 mm x120 5 mm excluding the dimensions of DIN rail and wall mounting components Mounting mode DIN rail or wall mounting Heat removal method Ribbed aluminum casing heat dissipation without fan Outlet type front outlet for service top outlet for power supply and network management Shell protection IP40 Weight 1 kg Operating temperature 35 C 75 C Ambient conditions Storage temperature 45 C 85 C Humidity 10 95 non condensing 2 2 Service Interface 1 Four 10Base T 100Base TX RJ45 ports Each RJ45 port has self adaptation function capable of automatically configuring to 10Base T or 100Base TX state and automatically working in full duplex or half duplex operation mode supporting automatic MDI MDI X connection The transmission distance is less than 100m 2 Four uplink redundant 10Base T 100Base TX RJ45 interface include
28. rface in which one Ethernet port is taken as the receiving terminal to connect to the port of other equipment MDI X Medium Dependent Interface Cross over 33 Publisher Beijing KYLAND Telecom Technology CO LTD Address 5 F Office Building Transport Center East of Xisanqi Bridge Haidian District Beijing China Website http www kyland com cn Postcode 100096 Tel 86 10 82900770 Fax 86 10 82900780 E mail marketing kyland com cn DAVANTEL DESARROLLOS AVANZADOS EN TELECOMUNICACIONES S L BARCELONA MADRID C PARDO B BAJOS C ARTURO SORIA 320 08027 BARCELONA 28033 MADRID TEL 34 933 408 712 TEL 34 913 023 758 Fax 34 933 401 399 www davantel com info davantel com
29. terminal locking screws to firmly connect the terminal with the power connector o Termhnal Locki ng Scr eve Locki ng Screw for Pover SOS Cabl es Power G ound 424V Prot ect i on G ound Figure 3 5 Wiring diagram for DC power terminal Alarming relay output terminal The terminal is a group of normally open contacts of the alarming relay of equipment Its figuration is the same as that of power input terminal Alarming enabling message such as power failure alarming port link alarming network alarming etc can be set via network management In normal state without alarming the terminal is in open state when any alarming message appears the terminal is in closed state It can be externally connected to other switching value collecting equipments or alarming lamps or alarming buzzers so as to timely prompt the operation personnel in case alarming occurs The maximum withstand voltage of the relay terminal is DC30V and the maximum input power 24VA Figure 3 6 is the schematic diagram of the equipment when it is connected an alarming indicator and the wiring method for other applications is similar Its wiring and mounting procedures are the same as those of power terminal Warning Light 24VA MAX ra Hi Terminal Locking Screw amp LA LO Locking Screws for Power Cables DC
30. the Packet in the ports can be affected by this function Each port of KIEN5000 supports 2 levels high low prioritization Layer 2 Switching Switches work in two ways Cut Through and Store and Forward In Cut Through a data packet is immediately relayed further after detecting the target address in Store and Forward a data packet is first read in completely and checked for errors before the switch relays the same KIEN5000 employs Store and Forward that is a switching mode widely used IGMP IGMP means Internet Group Multicast Protocol KIEN5000 supports IGMP and query Setting for Working Mode of Port KIEN5000 is able to set the working mode of all ports through management full half duplex auto sensing enforced full half duplex enforced 10M 100M etc Broadcast Storm Control Broadcast storm is the ceaseless transfer of broadcast frame or multicast frame in bridge which is caused by loop and will waste much bandwidth The purpose of broadcast storm control is to optimize the performance of switch network KIEN5000 supports the broadcast storm based on percentage With the control percentage the broadcast flow of KIEN5000 will be monitored and controlled effectively The switch will filter out the over flow and ensure the flow percentage is normal once the bandwidth of broadcast flow exceed the limit Alarming KIEN5000 offers the alarming functions for power port link and network Through management software all the alarming fu
31. ther cables and connectors necessary for mounting are available 4 2 Main unit mounting 4 2 1 Rail mounting For most industrial applications standard 35 mn DIN rail mounting is very convenient when taken out from the packing box the rear panel of KIENS5000 has already fitted with a green plastic connector socket for DIN rail Rail mounting dimensions are shown in Figure 4 1 If it is necessary to mount KIEN5000 on DIN rail check the mounting conditions of DIN rail before mounting including the following two items 1 Whether DIN rail is firmly fixed whether any other equipment is fitted DIN rail whether there is adequate space for mounting 5000 Whether there is power inlet DIN rail suitable for KIEN5000 operation 128 5mm 142mm ETE DIN Rail connecting seat Figure 4 1 Rail mounting dimension of KIEN5000 After selecting the proper position for mounting KIEN5000 mount KIEN5000 on DIN rail according to the following procedures 1 Insert the lower part of DIN rail into the fixing slot with spring supporting in the lower part of the DIN rail connector socket Slightly rotate the equipment upwards from bottom panel of KIEN5000 as shown in Figure 4 2 a As shown in Figure 4 2 b clip DIN rail into the DIN rail connector socket and ensure that KIEN5000 equipment has been reliably mounted on DIN rail 18 P DIN Rail Spring Figur
32. trial Ethernet Switch 1 10 100Base T TX Ethernet ports adaptive full half duplex High speed redundant ring with recovery time 300ms Chinese management supports Telnet SNMP protocol Supports VLAN to control broadcasting domain and segment flow Alarm relay output power supply and port link o oc F e m Broadcast storm control Powerful Management Function 1 2 3 4 2 Manage system can be done in web browser or via Telnet Individual naming for each device in the network Setting and query of VLAN Setting and query for alarm of power and ports link Setting and query for port working mode prioritization and rate Industrial Power 1 2 3 Industrial power input of DC24V DC18V 36V Reliable protection for EMC and against over current over voltage Redundant power input Rugged Design 1 2 3 Ribbed heat removal design fanless operation at 35 C to 75 C Solid IP40 housing Easy DIN Rail mounting or optional wall mounting 1 3 Packing list and unpacking check 1 Packing list The packing case includes the following items KIEN5000 1 unit 3 core DC power terminal 2 pieces 2 core alarming output terminal piece User s Manual for KIEN5000 Industrial Ethernet Switch 1 copy Customer Service Guideline 1 copy 3 grounding cold pressed terminal M3 X 8 grounding screw piece each Unpacking check Before opening the case place it stably pay attention to the
33. used Unused Note denoting cable polarity Definition of straight through cable from RJ 45 8 pin to RJ 45 8 pin The connection sequence is in turn Orange white Orange Green white Blue Blue white Green Brown white and Brown Figure A 2 Cable sequence of straight through cable Definition of Cross cable from RJ 45 8 pin to RJ 45 8 pin xd The connection sequence is in turn Orange white Orange Green white Blue Blue white Green Brown white and Brown Pron White Green Orange white Blue Blue white Orange Brown white and rown 30 Figure A 3 Cable sequence of cross over cable Appendix B Cable Type and Specifications The cable type and specifications are shown as table B 1 Table B 1 Cable type and specifications Cable Type Max length Connector 10Base T Cat 3 4 and 5 100 ohm UTP 100m 328 foot RJ 45 100Base TX Cat 5 100 ohm UTP 100m 328 foot 32 Appendix C Glossary Twisted pair standard of Cat3 Cat4 and Cat5 in IEEE specification for 10Base T 10Mbps Ethernet Twisted pair standard of Cat5 or above in IEEE specification for 100Base TX 100Mbps Fast Ethernet A characteristic that is automatically configured to adaptive mode for the Adaptive speed duplex and traffic control port The information capacity that the channel can transmit For instance the Bandwidth bandwidth of the Fast Ethern