1. Proper maintenance is important to achieve optimum performance from the heat pump The ability to properly perform maintenance on this equipment requires certain mechanical skills and tools If you do not possess these skills contact your dealer for maintenance Consult your local dealer about the availability of maintenance contracts Routine maintenance should include the following Regular Cleaning A CAUTION DO NOT touch any of the internal electrical components while cleaning the unit The area around the unit and the vicinity of any other appliances must be kept clear and free of combustible materials gasoline and other flammable vapors and liquids Do not store or use flammable items such as gasoline paint varnish or strippers in the vicinity of the unit Inspect the condensate drain at the beginning of each cooling season Remove any debris Annually inspect the physical support of the unitto ensure that itis physically sound without sagging cracks gaps etc e Air Filters A WARNING Never operate the unit without a filter in the return air system Dust and lint in the return air can build up on the internal components resulting in loss of efficiency equipment damage and possible fire risk Inspect and clean or replace air filters at the beginning of each heating and cooling season or more frequently if required A clogged filter could cause airflow related problems and reduce the overall efficiency
2. desired temperature level The compressor outdoor fan and blower motor will cycle on and off to maintain the indoor temperature at the desired heating level NOTE If the temperature level is re adjusted or the system mode is reset the fan and compressor in the outdoor unit may not start immediately A protective timer circuit holds the compressor and the outdoor Temperature Selector Figure 1 Digital Thermostat fan off for approximately three minutes following a previous operation or the interruption of the main electrical power Emergency Heat Some thermostats may include a system mode called EM HT or AUX HT etc This is a back up heating mode that should only be used if a problem is suspected With the mode set to EM HT etc the compressor and outdoor fan willbe locked off and supplemental heat electric resistance heating will be used as a source of heat Sustained use of electric resistance heat in place of the heat pump will result in an increase in electric utility costs Operating the Heat Pump for Automatic Cooling amp Heating 1 Set the thermostat system switch to AUTO and the thermostat fan switch to AUTO See Figure 1 NOTE Thermostats will vary Some models will not include the AUTO mode and others will have the AUTO in place of the HEAT and COOL and some will include all three 2 Setthe thermostat temperature to the desired heating and cooling temperature level s The outdoor unit and the indo
3. of your unit Always replace disposable filter s installed in your system only with the same size dimensional filters that are being replaced System Integrity e The unit should be kept closed and sealed Check integrity of panel tubing seals Make sure all panels are in place e Check integrity of tubing insulation Both tubing lines between the unit and indoor air handler should be fully covered with foam insulation TROUBLESHOOTING Before you call a Technician check the following e Check the thermostat setting Make sure the system mode and temperature settings are correct e Check the electrical panel for tripped circuit breakers e Check the filters for dust accumulation e f the items above don t resolve your problems then call your nearest service technician WARRANTY INFORMATION A warranty certificate with full details is included with the equipment Carefully review these responsibilities with your dealer or service company The manufacturer will not be responsible for any costs found necessary to correct problems due to improper setup improper installation adjustments improper operating procedure on the part of the user etc Some specific examples of service calls which are not included in the limited warranty are e Correcting wiring problems in the electrical circuit supplying the equipment e Resetting circuit breakers or other switches e Adjusting or calibrating of thermostat We Encourage
4. Professionalism LE etan Ko YOUR Y Y MEMBER EXPERTISE v MEMBER COMPANY Intertek Certification by NATE ale E gt ence NORDYNE f COMPLETE COMFORT GENUINE VALUE Specifications amp illustrations subject to change fl I I ll Il Without notice or incurring obligations 11 14 7097310 NEW
5. USER S MANUAL GEOTHERMAL HEAT PUMP IMPORTANT SAFETY INFORMATION WARNING To avoid possible equipment damage fire or death the following instructions must be observed regarding unit maintenance and operational procedures Please read all information in this manual thoroughly and become familiar with the capabilities and use of your appliance before attempting to operate or maintain this unit Pay attention to all safety warnings and any other special notes highlighted in the manual Safety markings are used frequently throughout this manual to designate a degree or level of seriousness and should not be ignored WARNING indicates a potentially hazardous situation that if not avoided could result in personal injury or death CAUTION indicates a potentially hazardous situation that if not avoided may result in minor or moderate injury or property damage Keep this literature where you have easy access to it in the future If a problem occurs check the instructions and follow recommendations given If these suggestions don t eliminate your problem call your servicing contractor Do not attempt to service this unit yourself To achieve optimum performance and minimize equipment failure it is recommended that periodic maintenance be performed on this unit The ability to properly perform maintenance on this equipment requires certain mechanical skills and tools Please consult your dealer for maintenance information an
6. d availability of maintenance contracts The area around the unit a must be kept clear and free of combustible materials gasoline and other flammable vapors and liquids Do not store or use flammable items such as paint varnish or strippers in the vicinity of the unit Do not use the area around the unit as a storage area This area must be kept clean and clear of loose or exposed insulation materials Examine the unit s area when it is installed or when insulation is added since some insulation materials may be combustible Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water Familiarize yourself with the controls that shut off the electrical power to the unit If the unit needs to be shut down for an extended period of time turn off electrical power at the circuit breaker For your safety always turn off the electrical power before performing service or maintenance on the unit Panels should be kept in place at all times Only trained qualified personel should remove the panels when servicing or performing maintenance A WARNING e Under no circumstances should the appliance owner attempt to install and or service this equipment Some local codes require licensed installation service personnel for this type of equipment Improper service adjustment or maintena
7. maintenance on this equipment requires certain tools and mechanical skills OPERATING INSTRUCTIONS Thermostat styles vary Some models may not include the AUTO mode and others will have the AUTO in place of the HEAT and COOL Others may include all three Please refer to the thermostat s User Manual for detailed programming instructions The thermostat should be mounted about 5 feet above the floor on an inside wall and not on an outside wall or other location where its operation may be adversely affected by radiant heat from fireplaces sunlight or lighting fixtures and convective heat from warm air registers or electrical appliances oe Operation Only Set the thermostat s system mode to COOL or AUTO and change the fan mode to AUTO See Figure 1 2 Set the temperature selector to the desired temperature level The outdoor fan compressor and blower motor will all cycle on and off to maintain the indoor temperature at the desired cooling level NOTE If the temperature level is re adjusted or the system mode is reset the fan and compressor in the outdoor unit may not start immediately A protective timer circuit holds the compressor and the outdoor fan off for approximately three minutes following a previous operation or the interruption of the main electrical power Taare Operation Only Set the thermostat s system mode to HEAT or AUTO and change the fan mode to AUTO See Figure 1 2 Set the temperature selector to the
8. nce may cause explosion fire electrical shock or other hazardous conditions which may result in personal injury or property damage Read these instructions thoroughly before using the equipment Follow all precautions and warnings contained within these instructions and on the unit Improper installation adjustment alteration service or maintenance can cause personal injury or property damage For assistance or additional information consult a qualified installer or service agency Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance DO NOT DESTROY PLEASE READ CAREFULLY amp KEEP IN A SAFE PLACE FOR FUTURE REFERENCE ABOUT THE SYSTEM Geothermal heating cooling systems operate via sub surface conductive heat transfer using the naturally renewable temperature of the earth s crust as a heat source in the winter and as a heat sink in the summer This unit has been tested for capacity and efficiency and will provide many years of safe and dependable comfort providing it is properly installed and maintained With regular maintenance this unit will operate satisfactorily year after year Abuse improper use and or improper maintenance can shorten the life of the appliance and create unsafe hazards Toachieve optimum performance and minimize equipment failure it is recommended that periodic maintenance be performed on this unit The ability to properly perform
9. or blower will then cycle on and off in either the heating or cooling mode of operation as required to automatically maintain the indoor temperature within the desired limits Operating the Indoor Blower Continuously The continuous indoor blower operation is typically used to circulate the indoor airto equalize a temperature unbalance due to a sun load cooking or fireplace operation Set the thermostat fan mode to ON Figure 1 The indoor blower starts immediately and will run continually until the fan mode is reset to AUTO The continuous indoor blower operation can be obtained with the thermostat system mode set in any position including OFF Shutting the Heat Pump Off Change the thermostat s system mode to OFF and the fan mode to AUTO See Figure 1 NOTE The system will not operate regardless of the temperature selector setting HEAT PUMP MAINTENANCE WARNING This heat pump contains liquid and gaseous refrigerant under pressure Installation and servicing should only be attempted by qualified trained personnel thoroughly familiar with the equipment and safe responsible refrigerant handling procedures Failure to comply with this warning could result in equipment damage personal injury or death WARNING To prevent electrical shock personal injury or death disconnect all electrical power to the unit before performing any maintenance or service The unit may have more than one electrical supply

Download Pdf Manuals

image

Related Search

Related Contents

Panasonic DMC-ZS8S + 16GB MC  HP SureStore Optical 160ex (C1150J#ABA) External Magneto  Manual do utilizador HeartSine samaritan® PAD SAM 350P  Operating Instructions Mode d'emploi Manual de  Technovit 7200_7210_7230 - bei Heraeus Kulzer Technik  取扱説明書  Bluetooth+NFC搭載アウトドアスピーカー MXSP  Bryant CD5A User's Manual  