1. ee EEEN E Arm Disarm Voice Prompt This product has this function when you arm disarm it it will give voice prompt system armed disarmed You can deactivate it if you do not need In setting status first input 83 then 0 1 and finally press to confirm The main unit will make a long beep and voice prompts setting completed please enter instruction Operating method 83 gt 0 1 gt 1 activate voice prompt for arm disarm factory default 0 deactivate voice prompt for arm disarm 19 27 28 For example Set arm disarm voice prompt OFF Operating method 83 gt 0 gt Voice Prompt for All Settings For all above settings you could hear the voice prompt such as setting completed please enter instruction delete completed You can deactivate the voice if you do not need them In setting status first input 84 then 0 1 and finally press to confirm The main unit will make a long beep and voice prompts setting completed please enter instruction Operating method 84 gt 0 1 gt 1 activate voice prompt for all operations factory default 0 deactivate voice prompt For example Set voice prompt OFF Operating method 84 gt 0 gt Note after you deactivate this function all the voice including arm disarm voice will not work Tamper Alarm Setting There is a tamper alarm button at the back side of the
2. Same ses Technical Parameters Power supply AC 220V 10 DC 12V Built in NI HI rechargeable battery Standby Current lt 60mA Alarming Current lt 450mA GSM band 850 900 1800 1900MHz Wireless Frequency 315 433 868MHz 0 5MHz Wireless receiving sensitivity 5mV m Anti interference 1V m Frequency range 20 1000MHZ Working Temperature 10 C 40 C Humidity lt 90 no fog Wireless detectors 99pcs Alarm Defense Zone Arm Home Arm Type Information aa Wired defense zone 95 98 Emergency alarm yes Operation Password 1234 Off Components List Main panel 1 pe Remote controller 2 pcs Siren 1 pc Wireless PIR sensor 1 pc Wireless Door sensor 1 pc Power adapter DC 12V 1 2A 1pc Back up battery Ipc User manual 1 pe Care and Maintenance The alarm system has excellent design and uses advanced technologies It shall be used with care The following suggestions are required to maintain your obligations under the warranty terms and for prolonging the service life of the system Place the control panel and all parts and accessories out of children s reach Keep the alarm system dry Rain humidity and various fluids or moisture all will corrupt the electronic circuit 28 lt V Do not use or place the alarm system in dirty locations otherwise the electronic elements will be damaged Do no place the system in excessively hot locations High temperature will shorten the ser
3. Pressing 0 means the panel will make coding signal to the siren this signal will last for 3 seconds So please make sure the siren is in coding status during this 3 second period Wireless Siren Coding Encryption In setup status use keypad to input 43 then input the number 0001 12 14 9999 and then input to confirm You will hear a long beep and a voice prompt setting completed Operating method 43 gt A gt A indicates the code number 01 99 For example set the wireless coding number as 10 Operating meth Sete casa ORR Si E a 143 iG E ee eee eee J Time Setting of Out Arm Delay Default 60 sec In setup status use keypad to input 44 then input delay time 01 99 and then input to confirm You will hear a long beep and a voice prompt setting completed Operating method 44 gt AA gt AA indicates the alarm delay time 01 99 seconds For example set the wireless coding number as 99 Operating method 44 gt 99 gt LCD display Note The setting is effective only with the panel keyboard operation The operation by remote controller or SMS is immediate arm without delay 15 Time Setting of Alarm Delay Default 40 sec In setup status use keypad to input 45 then input delay time 01 99 and then input to confirm You will hear a long beep and a voice prompt setting completed 13 16 17 Operating method 45 g
4. SPK Do not mix the two cables together when connecting Otherwise it will damage the transistor in the main panel Function Settings 1 Initialization Please insert SIM card and plug in power adaptor and then power on the 6 system the time clock displays 12 00 on the LCD screen the GSM starts flashing and the main panel starts to detect the GSM network until a long beep Then the GSM indicator goes out indicating the system comes into disarm status Enter Settings In the state of disarm input 4 digit password default 8888 by the keypad on the main unit and press button to confirm You will hear a voice prompt please enter instruction At the same time SET indicator is on without flashing and 0000 displays on the screen indicating the system enters setting status You can perform different settings repeatedly as long as the system keeps in setting status The system will exit setting mode and return to disarm status if you don t press any keypad button for 40 seconds Note In setting status press CALL button can delete the numbers input The system default password is 8888 Operating method XXXX gt XXXX indicates the 4 digit password Exit Settings Press and buttons the main unit emits a long beep and exits settings The SET indicator goes out and the system returns to disarm State Operating method x gt Factory Reset In disarm status use keypad to input 9
5. the LCD screen will display the exact alarming time of this defense zone Press 2 you can upturn to check the previous alarming record press 8 downturn to check and press to exit checking For example the 51st defense zone the 7th alarming alarming time 12 10 August Ist 2008 LCD display for one second g E 25 and then display the alarming time Te L You can also check the alarm records by SMS Max Latest 9 records SMS Check Command Remote Control Password Default 1234 3 Reply SMS Eg Alarm record NOI Zone 05 TIME 11 06 25 11 37 It indicates the first record wireless zone 5 alarm time NO9 Zone 19 Time 11 06 25 11 45 It indicates the ninth record wireless zone 19 alarm time 11 GSM Signal Checking Before installing the main unit you should check the signal of the installing place in order to ensure the unit can perform well In setup state input 81 gt the main unit will make a long beep and display 00 XX XX indicates the intensity of the GSM signal And the intensity should be within the range of 07 31 if it s less than 07 you should change place This icon Jl indicates the signal intensity When the intensity number is 0 7 this icon will not be shown when it s 8 15 this icon will be flashing when the number is larger than 16 this icon will be on the screen without flash For example if the signal intensity is 12 it will display as 26
6. panel If you install the panel with the bracket included in the standard pack this button will be pressed down When someone is trying to disassemble the panel the button will be loosen once the bracket is taken off and the system will make alarm at the same time In setting status first input 87 then press 0 1 and finally press to confirm The main unit will make a long beep and voice prompts setting completed Operating method 87 gt 0 1 gt 0 Tamper alarm OFF factory default 20 29 30 1 Tamper alarm ON For example Set Tamper alarm ON Operating method 87 gt 1 gt Note The alarm SMS is zone 99 emergency alarm IMEI Checking In setting status first input 88 and then press to confirm The 15 digit IMEI code will be displayed separately in 4 pages 2 seconds per page on the screen SMS Notification for Power Failure Recovery In Out Arm status if the main panel is powered off the built in battery will supply power and main unit will send SMS power charger off to all the three preset SMS receiving numbers In Out Arm status if the main panel recovers power it will send SMS power charger on to all the three SMS receiving numbers While in Disarm or Home Arm status it does not have this function Operation Instructions 1 System status There are 4 statuses as following Arm defense zone 1 99 will alarm when detectors are triggered lt gt Hom
7. 2 YEAR WARRANTY 007M2K User s Manual Profile For a better understanding of this product please read this user manual thoroughly before using it Contents Function Introduction 3 Alarm Host Diagram 3 Functions Settings 5 Initialization 5 Enter Settings 5 Exit Settings 6 Factory Reset 6 Coding of Remote Controller 6 Delete Remote Controller 7 Coding of Defense Zone 7 Delete Defense Zone 7 Change Password 8 Change Operation Password 8 Change Program Password 8 Clock Setting 8 Timing Settings 9 Timely Arm 9 Timely Disarm 9 Timing Control 10 Wireless Transmission Control Wireless Siren Coding Encryption Out Arm Delay Setting Alarm Delay Setting Alarm Number Setting 10 Delete Phone Number 11 SMS Number Setting 11 Delete SMS Number 11 SMS Notification for Arm Disarm Defense Zone Programming 12 Home Arm Defense Zone Setting 12 Voice Recording 13 Arm Disarm Siren Sound Setting Emergency Help Siren Setting Arm Disarm Voice Prompt Voice Prompt for All Settings IMEI Checking Siren Setting 13 Operation Instructions 14 System Status 14 Remote Controller Operate 14 Out Arm 14 Home Arm 15 Disarm 15 Answer Alarm Call 15 Remote Control 16 Emergency Help 17 System Dialing Function 17 Alarming Record Checking 17 GSM Signal Checking Function Instruction b BEG 4 wired and 99 wireless defense zones L
8. 34 Note the last five functions could be realized only when the GSM signal intensity reaches 20 35
9. 5175308246 and press to confirm all the LED indicators will be on for 2 seconds and you will hear a long beep The main unit gets all its settings cleared and restores 7 to its factory settings successfully Operating method 95175308246 gt 5 Coding of Remote Controller Extra remote controller has to be code to the alarm host in order to perform normally The one in the standard package has been coded In setup state use keypad to input 20 input the remote controller number 1 8 and then press to confirm The main unit emits a long beep and you will hear remote control coding The indicator is on without flashing press any button on the wireless remote controller the main unit makes a long beep and you will hear coding completed 8 indicator goes out indicating the remote controller succeeds in coding Operating method 20 gt A gt A indicates 1 8 remote controllers number You can add maximum 8 remote controllers LCD display a a cs es ees 6 Delete Remote Controller The remote controller can t control the main unit after it s deleted In setup state use keypad to input 21 then input the remote controller number 1 8 and then press to confirm The main unit emits a long beep and the Signal indicator flickers once You will hear a voice prompt delete completed Operating method 21 gt A gt A indicate
10. A gt XX indicates 01 99 is defense zone 1 to defense zone 99 A indicates 16 22 23 O no alarm under home arm status even the sensor is triggered 1 alarm under home arm status Example set sensor in defense zone 11 make alarm under home arm Status Operation 61 gt 11 gt 1 gt Example set sensor in defense zone 12 not make alarm even when it s triggered under home arm status Operation 61 gt 12 gt 0 gt After this setting when you home arm the system sensor in defense zone 55 will not work Note Home arm status is suitable for all defense zones including wired defense zones Voice Recording In setup state use keypad to input 701 and then press to confirm The main unit will emit a beep and the indicator is on and after 10 seconds countdown recording starts record at 30cm away from the main unit with moderate tone 10 seconds later the main unit will make a beep indicating the recording stops and the recorded voice will replay Operating method 701 gt LCD display a Ao J Arm Disarm Siren Sound Setting After you activate this function when you arm the system the external siren will sound one short beep and when you disarm it there will be two short beeps In setting status use keypad to input 75 then set siren sound OFF ON 17 by 0 1 button and finally press to confirm voice prompts setting comple
11. CD screen with time clock display Voice prompt for all operations 3 groups of timely arm and disarm Can store 6 phone numbers when alarming system will make alarm call to these numbers automatically Can store 3 SMS numbers when alarming system will send alarming SMS automatically One programmable 12V relay output Tamper alarm function there is a button at the back side of the panel it will make alarm once the button is loosen 10 second automatic message recording Built in artificial intelligent digital voice announcer Built in artificial intelligent English message Can send SMS to arm disarm check alarm record Can set arm and alarm delay time Built in wireless transmitter for convenient connection to wireless siren customized Users can make calls by using keypad on main unit just like a telephone One key control function Out Arm Home Arm Remote Arm SOS fire gas door hall window balcony and boundary places alarm Real time delay 24 hours bypass defense zones programming function Wireless coding easy to add additional wireless accessories Remote control Arm Disarm Monitor and Intercom by phone SMS alarm for power failure or recovery Built in NI HM rechargeable battery Alarm Host Diagram In order to make the main unit get the wireless signal well for all wireless accessories please put the alarm host at the central place of your defense area Make sure it s away from large met
12. EE gt FF gt AA indicates the last 2 digits of the present year BB indicates the 2 digits of the present month CC indicates the 2 digits of the present date DD indicates the 2 digits of the present hour EE indicates the 2 digits of the present minute FF indicates the 2 digits of the present second For example set the time as 15 35 40 Oct Ist 2009 Operating method 32 gt 09 gt 10 gt 01 gt 15 gt 35 gt 40 gt 10 11 Timing Settings 1 Timely Arm In setup status use keypad to input 33 35 then input the hour AA and minute BB of the time you want to set to arm and finally input to confirm You will hear a long beep and a voice prompt setting completed Operating method XX gt AA gt BB gt XX indicates the address code 33 34 35 of the timely arming AA indicates the hour of the setting time BB indicates the minute of the setting time For example set the arm time as 10 45pm Operating method 33 gt 22 gt 45 gt LCD display p 2 Timely Disarm In setup status use keypad to input 36 38 then input the hour AA and minute BB of the time you want to set to disarm and finally input to confirm You will hear a long beep and a voice prompt setting completed Operating method XX gt AA gt BB gt XX indicates the address code 36 37 38 of the timely disarming AA indicates the hour of the setting time BB indicates the minute of the se
13. Number Setting SMS Receiving number means when system is alarming it will send SMS to this mobile number You can set maximum 3 SMS numbers In setup state input 57 59 then input the SMS receiving number and then press button to confirm The main unit will make a beep the Signal indicator will flicker once and you will hear setting completed which indicate setup successfully Operating method XX gt YY YY gt XX indicates address codes of message receiving numbers from the first group to the third group 57 59 YY YY indicates the SMS receiving number For example setup 13822222222 as the first SMS receiving number Operating method 57 gt 138222222 gt Note the sms receiving number can be maximum 15 digits Delete SMS Receiving Number In setup state use keypad to input 57 59 and then press button to confirm The main unit will make a beep the Signal indicator will flicker once and you will hear delete completed which indicate SMS number is deleted successfully Operating method XX gt XX indicates address codes of SMS receiving numbers from the first group to the third group 57 59 For example delete the first SMS user number from the system Operating method 57 gt Defense Zone Programming 15 If you want to change the alarm attribute of defense zone such as turn off the siren when system alarms you can do it by defense zone programm
14. al objects and household appliances which may cause high frequency interference as well as barriers such as reinforced concrete wall or fire door etc Main panel front schematic diagram f ji 5 Status ma saai eifo as sos Indicator Speaker LCD display Alarm Fire Alarm Gas ma Window Alarm SOS Hall Alarm Balcony Alarm MIC Touch Keypad Out Arm Home Arm Call Out Emergency Back cover schematic diagram Back cover schematic diagram Tamper Alarm Button Fix Bracket Power Switch z DC 12V Input FARA EEEE Hii a g SIM Card Socket Lead Wire Slot PRARORNINSIADS PCB CHOI OO o Wired Ports Wired ports Positive of siren red cable Negative of siren black cable Positive of two way speaker red cable Negative of two way speaker black cable 5 Pl 12V output by remote control please refer to Operation Instruction part ooo oom ooo 7 P2 Linkage output port 2 There will be 12V output once the system is armed and be off once it s disarmed ex oom 9 fz Wired sensor 1 zone number 95 Note 1 LB and LB are to connect external speaker If you think the internal speaker is not loud enough please contact us for professional speakers 2 Connect one cable of the wired sensor to GND and the other to Z 1 Z2 Z3 Z4 3 Please pay attention to the siren connection SPK and
15. digit new password and then press to confirm The main unit will make a long beep and you will hear a voice prompt setting completed Operating method 30 gt XXXX gt XXXX indicates the new 4 digit password For example change the system password to 1012 Operating method 30 gt 1012 gt LCD display E 10 2 Change Program Password Program password is the password you should input in order to setup the system Default 8888 In setup status use keypad to input 31 then input the 4 digit new password and then press to confirm The main unit will make a long beep and you will hear a voice prompt setting completed Operating method 31 gt XXXX gt XXXX indicates the new 4 digit password For example change the system password to 2846 Operating method 31 gt 2846 gt LCD display pe 4 lee 46 C 4 Note the operation password and the programming password can not be set as the same number Clock Setting In setup status use keypad to input 32 then input the last 2 digits AA of the present year the two digits BB of the month the two digits CC of the date the two digits DD of the hour 24 hour system the two digits EE of the minute the two digits FF of the second and finally enter to confirm You will hear a long beep and a voice prompt setting completed Operating method 32 gt AA gt BB gt CC gt DD gt
16. e Arm in arm status the defense zone which is set as Home Arm will alarm when detectors are triggered lt Disarm defense zone 1 99 will not alarm when detector triggered except 24 hours defense zone lt System setup status In this status all defense zones will not alarm when detectors are triggered 2 Remote Controller Operation Users can use remote controller to set system as Out Arm Home Arm 21 Emergency Alarm Real time Disarm and etc lt Out Arm Press button lt Disarm Press button Home Arm Press 7 button lt Emergency Alarm Press A button system will alarm at once 3 Out Arm It means to guard all around your house while everyone is going out all the detectors of the host are always working when the detector is triggered by detecting source anti theft fire prevention gas leak etc the alarm system will sound the alarm Press ARM O button on keypad system will make a beep per second and totally 60 beeps The ARM indicator will be on without flashing It means Out Arm is set successfully Main unit operation Press ARM button the system will enter arm status 60seconds later or delay time set by user Remote controller operation Press MM button on remote controller system will enter OUT ARM mode immediately SMS remote operation The SMS command is Remote Control Password Default 1234 1 After the setting the host makes a Di sound ARM LED is on and you will receiv
17. e a SMS System armed Note SMS command can only be controlled by the preset three alarm SMS numbers LCD display 4 HomeArm 22 It means for the safety while somebody is at home you need to enable the peripheral door window balcony and boundary detectors of the alarm system while prevent from triggering the indoor detectors which may cause improper warning then you shall select Arm at Home let just part of the detectors work and disable the other parts Main unit Operation Press STAY button on keypad Remote Control Operation Press r button on remote controller once LCD display f 5 Disarm It means to stop the alarm when the main unit sounds the alarm or make the alarm system in the state of non warning After disarming even if you trigger the detector the main unit would not sound alarm excluding 24 hour defense areas Use keypad to input system password Default 1234 then press button ARM or STAY lights will be off It means disarm setting successful Main Unit Operation input system password Remote Control Operation Press Le button on remote controller SMS remote operation The SMS command is Remote Control Password Default 1234 2 After the setting the host makes Di Di sound ARM LED is off and you will receive a SMS System disarmed LCD display 6 Emergency Help Press SOS button on keypad or A button on remote controller or wireless pa
18. ing In setup state first input 60 then the defense zone number 01 99 then input defense zone type 1 4 then input alarm type 1 8 and then select siren on off 0 1 at last press to confirm You will hear the main unit emit a long beep and a voice prompt setting completed Operating method 60 gt AA gt B gt C gt D gt AA defense zone number 01 99 means zone 1 to zone 99 B defense zone type 1 real time defense zone 2 40 seconds delay defense zone 3 24 hours defense zone 4 bypass defense zone C alarm type 1 SOS Alarm 2 Fire Alarm 3 Gas Leak Alarm 4 Door Alarm 5 Hall Alarm 6 Window Alarm 7 Balcony Alarm 8 Boundary Alarm D siren ON OFF 0 OFF 1 ON For example set defense zone 12 to be 24 hour fire alarm and siren on Operating method 60 gt 12 gt 3 gt 2 gt 1 gt Note The programming is suitable for all defense zones including wired defense zones 21 Home Arm Defense Zone Setting Home arm defense sometimes for example when you are at home you want some of the sensors work while some do not you can do this setting In setup state use keypad to input 61 then choose the corresponding defense zone number 01 99 then choose Home Arm and then choose whether alarm 0 1 button and finally press to confirm The main unit will make a long beep and a voice prompt setting completed Operating method 61 gt XX gt
19. ion 1 SOS Alarm 2 Fire Alarm 3 Gas Leak Alarm 4 Door Alarm 5 Hall Alarm 6 Window Alarm 7 Balcony Alarm 8 Boundary Alarm D Siren ON OFF 0 OFF 1 ON 61 01 12 0 1 Home Arm Defense Zone Defense zone number 33 Setting O1 12 0 Home arm but not alarm 1 Home arm and alarm 70 1 4 Voice Recording 10 seconds 75 0 1 0 off default 1 on 76 0 1 Siren Setting in 0 off default 1 on Emergency Help mode 77 1 0 SMS Notification for Arm Disarm 81 GSM Signal Checking Intensity 07 31 if it s less than 07 you should change place 83 0 1 Arm Disarm Voice 0 off 1 on default Prompt 84 0 1 Voice Prompt for All 0 off 1 on default Settings 88 IMEI Checking 0 4 Alarming Record Press 2 upturn Checking Press 8 downturn Press Exit Dial telephone System Dialing Function number CALL 95175308246 Usesvilecaution operation password Arm by SMS Default operation 1 password 1234 operation password Disarm by SMS Default operation 34 password 1234 operation password Alarm Record Checking Default operation password 1234 operation password Turn on 12V output Default operation password 1234 operation password Turn off 12V output Default operation password 12
20. nic button the main unit will alarm and make call to the preset 23 user numbers 7 Answer Alarm Call When the main unit sounds alarm it will dial the preset numbers If no one answers the call the system will call the next user number automatically The system will call each preset numbers for 3 times in order If you answer the call you will hear the pre record voice You can set system via your telephone or mobile phone keypad If you hang up directly without answering the call the system will call each preset number for 3 times circularly Press Read the alarm information Press 1 Main unit stops alarming and Arm it stops calling users Press 2 Main unit stops alarming and Disarm it stops calling users Press 3 Siren off and monitors the scene for 60 seconds for continued monitoring press 3 again to monitor for another 60 seconds Press 4 Main unit starts a 60 second two way intercom It cannot be controlled by the mobile during the time of intercom Press 5 Linkage switch 1 12V output on Press 6 Linkage switch 1 12V output off 8 Remote Control Dial the number associated to the alarm main unit by phone mobile phone and after one ringing cycle you can hear a voice prompt Please enter password If the password is right you will here Press 1 to arm Press 2 to disarm Press 3 to Monitor Press 4 to Intercom If the password is wrong you will hear a prompt voice wrong passw
21. ord please re enter Press 1 arm if finished successfully you will hear a voice prompt System armed Press 2 disarm if finished successfully you will hear a voice prompt System disarmed Press 3 monitoring for 60 seconds to continue monitoring press 3 24 again to monitor for another 60 seconds Press 4 two way intercom for 60 seconds You can t operate the main unit during this time Press 5 Linkage switch 1 12V output on Press 6 Linkage switch 1 12V output off For the above operation of arm disarm and output control you could also send SMS to realize The SMS content format is operation password default 1234 1 2 5 6 Note for each number pressing it is valid only you hear a DI confirmation sound Please reenter it if you do not hear the sound And sometimes for weak gsm signal you need to input for several times 9 System Dialing Function In disarm status you can use the main unit to make any call just like a land line telephone Dial telephone number on keypad press CALL button the main unit will make a beep and the Signal indicator will be flashing After the call press CALL button again the main unit will be in disarm status 10 Alarming Record Checking In disarm state input 0 then the main unit will make a long beep and enters the state of alarm record checking After displaying the alarm and defense zone number indicator for 1 second
22. s 30 password 31 password 32 AA BB CC DD EE FF 33 35 AA BB 36 38 AA BB 39 0 1 41 0 1 Change Operation Password Change Password System Time Setting Timely Arm Timely Disarm Timing Control turn on off the function of timely arm disarm Wireless Transmission Control Defense Zones Number 01 99 Defense Zones Number 01 99 Default 1234 Program Default 8888 AA year BB month CC date DD hour EE minute FF second 3 groups of auto arm time AA hour BB minute 3 groups of auto disarm time AA hour BB minute 0 OFF 1 ON 0 OFF 1 ON 42 01 99 Wireless Siren Coding Siren coding number 3 2 44 01 99 Out Arm Delay Time Default 60seconds Setting 45 01 99 Alarm Delay Time Setting Default no delay 51 56 Phone Alarm Number Setting number 51 56 Delete Phone Number 57 59 Phone SMS Receiving Number number Setting 57 59 Delete SMS Receiving Number 60 AA B Defense C D 4 Programming 6 groups of alarming user number 3 groups of SMS receiving number AA Defense zone number 01 99 B Defense zone type 1 real time 2 40 seconds delay 3 24 hours 4 bypass C Defense zone locat
23. s 1 8 remote controllers number 7 Coding of Defense Zone Wireless detectors have to be coded to the main unit in order to trigger it alarm The wireless PIR and door sensor in the standard package have been coded In setup state use keypad to input 23 input the defense zone number you want to code 01 99 and then input to confirm The main unit 8 emits a long beep and the corresponding defense zone is displayed on the screen You will hear a voice prompt detector coding Then trigger a wireless detector to emit a wireless signal after receiving the signal the main unit makes a long beep and you will hear coding completed the indicator goes out at the same time Operating method 23 gt XX gt XX indicates 01 99 defense zones number LCD display A Delete Defense Zone The wireless detector can t control the main unit after it s deleted In setup state use keypad to input 24 then input the defense zone number you want to delete 01 99 and then input to confirm The main unit emits a long beep and the defense zone indicator flickers once You will hear a voice prompt delete completed Operating method 24 gt XX gt XX indicates 01 99 defense zones number Change Password 1 Change Operation Password Operation password is the password used to disarm or remote control Default 1234 In setup status use keypad to input 30 then input the 4
24. t AA gt AA indicates the code number 01 99 For example set the wireless coding number as 65 Operating method 45 gt 65 gt HN Note Alarm delay is effective only when the correspondent zone of the detector is set as alarm delay zone Alarm Number Setting In setup state input 51 56 then input the voice alarm receiving number mobile number or telephone number and then press to confirm The main unit will make a long beep the Signal indicator will flicker once and you will hear setting completed which indicate voice alarm receiving number is set successfully Operating method XX gt YY YY gt XX indicates the 1 6 alarming user number 51 56 YY YY indicates voice alarm receiving phone number For example set 13811111111 as the first voice call number Operating method 51 gt 13811111111 gt LCD display E Note the alarm receiving number can be maximum 15 digits Delete Phone Number In setup state input 51 56 and then press to confirm the main unit will make a long beep and the Signal indicator will flicker once and you will hear delete completed which indicate the alarming user number is deleted successfully Operating method XX gt XX indicates the 1 6 alarming user number 51 56 14 18 19 20 For example Delete the third alarming user number from the system l L J SMS Receiving
25. ted please enter instruction Operating method 750 gt or 751 gt 0 sound OFF system default 0 1 sound ON Example set arm disarm siren alarm sound ON LCD display y ee E z0 OAN 3 24 Siren Setting in Emergency Help Mode Press Emergency SOS button on the remote controller or the keypad the system will make alarm immediately You can choose to activate the siren sound or not In setup state use keypad to input 76 and then 1 0 finally press to confirm The main unit will make a long beep and a voice prompt setting completed Operating method 76 gt A gt A indicates 0 siren off in Emergency Help mode 1 siren on in Emergency Help mode System default 0 siren off For example Set Emergency siren ON Operating method 76 gt 1 gt LCD display eee ee ee ee EE me 18 25 26 SMS Notification for Arm Disarm Default OFF In setup state input use keypad to input 77 and then 1 0 finally press to confirm The main unit will make a long beep and a voice prompt setting completed Operating method 77 gt 0 gt or 77 gt 1 gt 0 no SMS for arm disarm to the 3 alarm receiving numbers default 1 SMS for arm disarm to the 3 alarm receiving numbers For example send SMS when arm disarm Operating method 77 gt 1 gt LCD display ee ee
26. tting time For example set the arm time as 7 45am Operating method 36 gt 07 gt 55 gt LCD display i 3 Timing Control In setup status use keypad to input 39 then input the number indicating 11 12 13 turning on timely arm disarm 1 0 and then input to confirm You will hear a long beep and a voice prompt setting completed The factory default is off Operating method 39 gt 0 1 gt Q turn off the function of timely arm disarm 1 turn on the function of timely arm disarm For example turn on the function of timely arm disarm Operating method 39 gt 1 gt Note If turning on timely arm disarm function the icon J will display on the screen If turn off the function the icon will not display Wireless Transmission Control In setup status use keypad to input 41 then input the number 1 0 and then input to confirm You will hear a long beep and a voice prompt setting completed The factory default is off Operating method 41 gt 0 1 gt O turn off the function of wireless transmission 1 turn on the function of wireless transmission For example turn on the function of wireless transmission Operating meth Be E J Note after activating this function do as follows to set the wireless siren with the main unit Input 411 and then make the siren you want to set into coding status finally press 0 on the panel
27. vice life of electronic equipment damage batteries deform or even melt some plastic parts Do not place the system in excessively cold locations Otherwise condensation many occur and damage the circuit board of the alarm system It is recommended that you check and test the alarm system periodically Check the main unit every three months 1 Whether it can arm disarm normally 2 Whether it can dial the number for alarm normally 3 Whether it can receive wireless detectors signal normally 4 Whether the back up battery can work normally Check the wireless detectors once a month 1 Trigger wireless detectors to see if system can alarm normally 2 Check all detectors batteries to see if it s in low voltage 3 Check whether wireless detectors can send signal to the main unit normally Check the SIM card 1 Check the use of SIM card such as network signal balance etc 2 Make sure the PIN code verification of the SIM card is closed 3 Please keep the password and SIM card number safe in case that other people remote control the system illegally Since the alarm system is continuously in operation or standby 29 mode the supply adaptor of the control panel shall be connected to a safe and reliable socket Do not place the system near your bedroom or office table because the siren will make high loudness sound in the case of alarm which may adversely affect your rest or work If the alarm system
28. will not be used for a long time please disconnect the system from the power supply Please do not disassemble repair or alter the products without permission or it may cause accidents and faults lt gt Do not drop this product on the ground or on hard objects as it may lead to massive impact to cause faults and damages Without approval and consent of relevant authorities please do not set 110 119 or the alarm phone number of police station for this main unit Please read the suggestions above carefully and follow the instructions herein If any of the equipment does not work properly please send it to the dealer or authorized service point for repair We will try our best to solve the problem for you as soon as possible The following accessories are optional 30 e Wireless Outdoor Flash Siren Signal Repeater Wireless Keypad m e Glass Sensor Panic Button Remote Controller o Wireless Pet Smoke Detector Gas Detector Immune PIR Detector Optional sensors detectors are packed separately You can choose according to your specific requirements Operation Function Description Remarks Commands Program Password Enter settings Default password 8888 WEA 20 1 8 Coding of Remote Max 8 remote controllers Controller 21 1 8 Delete Remote Controller 31 23 01 99 Coding of Defense Zones 01 24 01 99 Delete Defense Zone