Home

AlphaCom Architects and Engineers Specification

image

Contents

1. PRESET GROUP CONFERENCE lt shall be possible to set up a group conference by dialling a 4 digit code then a group number followed by the conference number System shall allow up to 50 conference groups Dialling the preset group conference number shall include all members of the group and all members of the group shall be able to hear whoever is talking Each group member shall be able to speak to the group by holding down the simplex button on his master station It shall be possible to have a preset conference automatically activated by a remote alarm contact One person at a time shall talk in an individual conference Gertain stations can be programmed with the ability to override and take control of talking into or feeding the conference OPEN DUPLEX CONFERENCE It shall be possible to set up an open duplex conference by dialling a four digit code It shall be possible to have 20 different open duplex conferences Upon dialling the code the station will start ringing enter the conference by lifting the handset leave the conference by placing handset back on hook dial the four digit code to rejoin the open duplex conference It shall be possible to include a preset group of stations in an open duplex conference It shall be possible to program DAK keys on stations to allow for single button dialling to enter conference and also start a preset conference The number of participants in an open duplex conference
2. e S y BONS IR SENSE 7080 000 Dimensions W x D x H 124 x 344 x 63 mm 4 9 x 9 5 x 2 5 inch 33 Aug 2007 Architectural and Engineering Specification ei STENTOFON NOISE CANCELLING INDUSTRIAL MASTER STATION A B Io nm C m e Shall have access to all features in the exchange This industrial master station shall be weather resistant and designed for humid dirty and outdoor conditions The exterior casing shall be comprised of a chip resistant orange Macrolon with foil keyboard The stations shall include a keyboard foil with dialling buttons 0 9 manual M button for speech control and other functions cancel C button There shall be preset volume control and always privacy switch inside the station The station shall have a red LED indicator for incoming calls and station in use indication The station shall have an IP65 classification Temperature and humidity range must be 20 50 C 4 122Ff and 1096 85 RH shall include a noise cancelling microphone Shall include a preamplifier with 1000 ohm output impedance and greater than 40 dB signal to noise ratio Output power to external 20 70 Ohm loudspeaker shall be 1 5 W Output power from built in VOX operated power amplifier shall be 10 W in 8 20 Ohm separate 12 VAC 2 A power supply required Frequency response of input and output shall be 500 5 000 Hz Shall have connections for optional handset with microphone impeda
3. Dimensions W x H x D 10 x 230 x 263 mm 0 4 x 9 0 x 10 3 inch Available languages XX Nor 01 Fin 02 Dan 03 Ger 04 Eng 05 Fre 06 Swe 11 Programming tool AlphaVoC 42 Aug 2007 Architectural and Engineering Specification ei STENTOFON 5 2 4 DIGITAL NETWORK BOARD AE1 A This board shall provide independent E1 T1 interfaces to intercom exchanges B It shall be possible to use the board in different configurations to link modules and or nodes via digital links C The board shall match standard E1 T1 cables and CAT5 building cabling systems The board shall also provide fractional E1 T1 multiplexing capabilities E The capacity shall be 2 E1 T1 links with 32 audio time slots 7 RS232 ports for free use and 1 RS232 PC serial port F Frequency range shall be 300 3 400 Hz G 711 a law or u law coding G Data on RS232 shall be 9 600 and 38 400 baud speed E1 T1 2 048 1 536 Mbit sec H Impedance shall be 120 Ohm on E1 100 Ohm in CAT5 mode and 100 Ohm on T1 Shall include 2 red green amber LED indicators for board and link status The STENTOFON AC board for AlphaCom type 9305 000 complies with the above specifications Dimensions are W x H x D 10 x 230 x 268 mm 0 4 x 9 x 10 3 inch 5 2 5 POWER DISTRIBUTION BOARD PDB A The PDB board shall be used when it is necessary to supply additional equipment with power from the intercom exchange B The power board shall provide 5 V
4. K Shall include a 1 5 W built in loudspeaker Output power to external 20 70 Ohm speaker shall be 1 5 W M Output power from built in VOX operated power amplifier shall be 10 W in 8 20 Ohm separate 12 VAC 2 A power supply required N Frequency response of input and output shall be 500 5 000 Hz Shall have connections for optional handset with microphone impedance 200 600 Ohm P Shall include 3 x PG9 glands The following STENTOFON Industrial Sub Stations comply with the above specifications 7083 000 7085 000 3 buttons 1 button Dimensions W x D x H 160 x 260 x 92 mm 6 3 x 10 1 x 3 6 inch 36 Aug 2007 Architectural and Engineering Specification ei STENTOFON 5 1 7 CONTROL ROOM MASTER STATION The Control Room Master station shall be a compact desktop console with 1 4 modules Control Room Master Station unit CRM always required Handset unit DAK unit 1 or 2 CRM UNIT A B cg mmo oO EL mg Master station shall have access to all features in the STENTOFON AlphaCom exchange Shall include the following controls Dialling buttons 0 9 Manual M button for speech control and other functions Cancel C button Privacy switch Variable volume control Shall include 4 direct access keys DAK each containing two programmable LEDs Shall include a red Station on LED Shall include a 4 line 20 character alohanumeric LCD display with backlight Shall include a 3 1 6 watt
5. STENTOFON ARCHITECTURAL AND ENGINEERING SPECIFICATION AlohaCom E Integrated Security Audio and Building Communication System P 61 3 9729 6600 F 61 3 9729 0099 W www stentofon com au STENTOFON Communications Australia Pty Ltd 2 670 Mountain Highway Bayswater Vic 3153 E sales stentofon com au Architectural and Engineering Specification ei STENTOFON Table of Contents 1 1 1 1 2 1 3 ON d HN 4 SCOOPE OF WOpk ttt ttt ttt ttt ttt ttt ttti 4 QUALITY ASSURANCE AND WARRANTY eett tette 4 SIT Tue EEN 5 SYSTEM OPERATIONS REQUIREMENTS 1 eese rere rene nnn 6 SYSTEM PLANNING ssssssssiisssssseettiresseetttrrssbket intreb krtn rres annt r errs etane nrnna saarn rrna saanen rrna aaner rra aane 6 SYSTEM INSTALLATION TESTING AND TRAINING s 6 SYSTEM OPERATION AND USAGE ttt ttt 6 SYSTEM SUPPORT AND SPARES tette ttti 6 SYSTEM e A TE 7 AUDIO STATIONS s sissssseiiieeseseetttitrssstnttittssbbtttt tresa bbt trnns sebat ernn raS Aten nS S Sannen nrasane nenns saanen r rrans 7 INTEGRATION WITH IP IT ADMINISTRATION 9 INTEGRATION WITH OTHER BUILDING SECURITY SYSTEMS ssseee 10 Oe PIED ta EO Eel KE 10 miM eT B B imu NN ET T E T T TIT 11 TA ONAT RADI EE 11 FIRE ALARM ee P 11 VIDES URVEILANC E 11 POOE o gO ONE O EE 11 ALA
6. 000 Hz Output power shall be 1 W I Wall mount stations shall be in anodized aluminum suitable for wall mounting in flush or surface mount back box J Station may include 8 direct access keys DAK K Station may include a two lines 16 character information LCD display L Station may be equipped with a noise cancelling gooseneck microphone SUBSTATION WALL A Like Master Standard station without keyboard B Shall have one doorbell button pre programmed for call to one master station C Shall have internal preset volume control D Shall be IP54 protected The following STENTOFON Wall Mount Stations comply with the above specifications eeeertebooce Segggeeegeg 2 9 9 9 7040 000 7042 000 7043 000 7046 000 Master Standard Master Display Master Console Substation Wall Display Display 1 call button 8 DAK keys 8 DAK keys IP54 protected Gooseneck mic Dimensions for all stations are W x H x D 125 x 280 x 58 mm 4 9 x 10 9 x 2 1 inch Flush mount back box 6020 000 Surface mount back box 6030 000 31 Aug 2007 Architectural and Engineering Specification ei STENTOFON 5 1 4 Zomm DO EL m OZEgrm OPERATING ROOM MASTER STATION Master station shall have access to all features in the exchange Master stations shall include the following controls Dialling buttons 0 9 Manual M button for speech control and other functions Cancel C button Shall have preset variable volume
7. 8 40 C ALARM OVERIDE System shall allow priority calls and voice alarm messages to override standard intercom calls and come through speaker at full volume even when handset is in use privacy switch on and volume set low TONE TEST System shall have the capability to do a tone test of entire system This tone test shall test the speaker and microphone circuits of all standard stations This test can be performed automatically every day at a certain time or can be manually started to provide a system evaluation for troubleshooting purposes The results of the tone test are sent to the Syslog file HOTLINE CALL System shall have the ability to perform a hotline call from any master station This hotline call shall be performed by lifting the handset on a master station which in turn will place a call to a pre programmed station or feature for default 5 seconds Timer shall be system wide programmable for all stations EVENT HANDLING System shall be capable of providing programmable ASCII data strings to interface with external data systems such as CCTV Card Access etc These data strings shall be fully programmable to meet the needs required by the external systems It shall be possible to transmit ASCII data strings either on IP or serial link as desired 49 SYSTEM OPERATION 4 9 1 A 4 9 2 MASTER TO MASTER CALLS All master stations shall be able to call all other stations in the system unless specifically
8. Display 168 x 75x 176 mm 225 x 75x 176 mm 6 6 x 2 9 x 6 9 inch 8 9 x 2 9 x 6 9 inch Desk or wall mount Desk or wall mount 7001 210 7001 310 7070 090 Handset Handset Display Handset Display 112 x 132 x 260 mm 112 x 132 x 260 mm 112 x 132 x 260 mm 4 4 x 5 2 x 10 2 inch 4 4 x 5 2 x 10 2 inch 4 4 x 5 2 x 10 2 inch Desk mount Desk mount Desk mount Note to specifier Specify station type as desired 29 Aug 2007 Architectural and Engineering Specification ei STENTOFON 5 1 2 DUAL DISPLAY MASTER STATION A Master station shall have full access to all features in the exchange B Master station shall include the following controls Dialling buttons 0 9 Manual M button for speech control and other functions Cancel C button Privacy switch Variable volume control C Shall include up to 4x10 direct access keys with information text for each DAK on a 10 lines display D The direct access keys and DAK display text shall be easily programmed from the station and changed at any time Status information guidance and menus shall be shown on a large 4 lines graphic display Shall have 4 navigation keys for quick access to system menus and directory entries Shall include a red Station on LED IT omm Shall include a 2 1 6 watt speaker mounted in an acoustic baffle Shall include an electret microphone with 100 300 mV output and sensitivity 65dB 1KHz c Shall include a preamplifier with 1000 ohm o
9. Distribution Board PDB if relay is used Iro mm Current consumption shall not exceed 30 mA when the relay is active Board shall be fastened to mounting rail in the AlphaCom exchange The STENTOFON MADER board for AlohaCom type 9960 100 complies with the above specifications Dimensions W x H 70 x 100 mm 2 7 x 3 9 inch 5 2 9 REMOTE IN OUT CONTROL RIO A The RIO unit shall be included where auxiliary devices need to be operated from the intercom system and or where external alarm conditions need to be displayed as text or voice message given on intercom stations Shall operate on point to point connections RS232 or on a multi drop bus RS485 Each RIO unit shall have 8 inputs and 18 outputs All inputs and outputs shall be programmable from the intercom programming tool The outputs shall be connected to relay boards with 6 relays each It shall be possible to connect up to 30 RIOs to one intercom exchange It shall be possible to chain up to 10 units on one RS485 bus comm oO D It shall be possible to mount RIOs up to 1 km from the exchange when using RS485 There shall be status LED on the board and built in error indication The RIO units shall be monitored by the intercom exchange and error messages shall be displayed on the system station in case of device error The STENTOFON RIO board for AlphaCom type 9970 500 complies with the above specifications SM Dimensions W x H x D 225 x
10. For STENTOFON CRM IV Control Room Master Station Single Back box 135 x 320 x 75 mm 5 3 x 12 6 x 2 9 inch type 7006 180 Double Back box 265 x 320 x 75 mm 10 4 x 12 6 x 2 9 inch type 7006 181 Two Housing Mounting Kit single double or double double back boxes type 7006 182 5 1 8 TAMPER RESISTANT STATIONS HEAVY DUTY TAMPER RESISTANT SUBSTATIONS A Shall be used where vandalism is a threat to the equipment B Shall have one or two large call in buttons pre programmed for call request to master station or program distribution source Shall have internal preset volume control Shall include a red Station on LED Shall include a 3 1 6 W loudspeaker Shall include an electret microphone with 100 300 mV output and sensitivity 65dB 1 KHz o nimuoso Shall include a preamplifier with 1000 ohm output impedance and greater than 40 dB signal to noise ratio H Frequency response of input and output shall be 300 to 5 000 Hz Output power shall be 1 4 W J Stations shall be in Lo anodized aluminum suitable for wall mounting in flush or surface mount back box with tamper proof screws K Loudspeaker and microphone grille shall be protected with no penetration barrier L Temperature and humidity range shall be 10 to 40 C 50 to 104F 1096 85 RH The following STENTOFON Tamper Resistant Stations comply with the above specifications 7060 1010 Dimensions W x H x D 190 x 140 x 63 mm 7 5 x 5 5 x 2
11. Specification ei STENTOFON 4 9 3 4 9 4 When call is answered the following shall occur A connection tone is heard at both the receiving and calling station The flashing green LED illuminates solid on the appropriate button if direct dial unit is used The number and text of the station that is connected appears in the display An in use LED illuminates on the calling substation Clear two way communication shall take place Other calls from substations to the Control Room Master station during conversation shall each flash their appropriate direct access button LED if direct dial unit is used and sound the call in tone CALL FROM A CONTROL ROOM MASTER STATION TO ANY OTHER STATION A call shall be placed from a CRM station to any other station in the system by dialling the station number on the digit keypad or pressing the direct access key programmed for the actual station The display on the CRM station shall indicate the number and text of the called station When calling any other master station duplex hands free loud speaking communication shall be possible between the two stations When calling an elevator car or other security substation the press to talk button shall be used to control the conversation if needed for security purposes or privacy GROUP CALL FROM A CONTROL ROOM MASTER STATION A group call shall be initiated at a CRM station by dialling the number assigned to a pre programmed group of stati
12. and Building Communication Node from the IT administration network 9 Aug 2007 Architectural and Engineering Specification ei STENTOFON 3 3 INTEGRATION WITH OTHER BUILDING SECURITY SYSTEMS The Security Audio System shall be configured as a part of the entire Security Management System and provide seamless integration with systems like access control intrusion detection and alarm systems emergency notification audio paging and radio paging two way radios PBX system and public telephone networks video surveillance system fire alarm systems T reuny CCTV Multiplexer PA System anagemen EN UMS oubstation Entry Access ven WEM Private Hadio Star wire and or IP Network Private Radio Voice Interface j o o i Security Audio Node Fire Alarm Master Station Control Room 1 Figure 3 Main Systems for Building Security Management 3 3 1 OPEN INTEGRATION POINTS The Security Audio and Building Communication Node shall support the following types of open integration points Switches and relays Serial data protocols TCP IP protocols Analogue audio 0 dB 600 Ohm VolP audio using SIP Traditional telephone interfaces ISDN and analogue ET Security Management dE Server JE o IP Network Relay Switches
13. blocked or restricted through programming by touch dialling a 1 6 digit number or by using direct access buttons Once dialled both stations shall be able to converse hands free All standard features shall be available to all master stations in the node or over a network CALL FROM SECURITY SUBSTATIONS TO CONTROL ROOM MASTER STATION A call request shall be initiated from a substation by activating an alarm button or the call in button on the substation The call request shall indicate to the calling party with a flashing green LED and an audible call acknowledgment voice message to comply with ADA see options It shall be possible to start an external strobe light see options This call request shall be annunciated at the Control Room Master station as follows The display will show a call request from a station indicated by station number and associated text and type of call priority f several call requests are received without being answered they should be stored in a queue sorted on priority and time Arapidly repeating tone signal sounds and the direct access button associated with the calling station flashes if direct dial unit is used Call request shall be answered at the Control Room Master station by pressing the appropriate direct access button or by scrolling the displayed queue and pressing the direct access button pre programmed to answer call requests 26 Aug 2007 Architectural and Engineering
14. is typically 4 stations but by programming an open duplex conference can have more stations if desired PRIORITY AND CLASS OF SERVICE System shall have 4 levels of priority to allow or deny access to features such as voice or pocket paging all call group calls preset conferences telephone lines special interfaces groups of stations and text display of alarm messages System shall include 16 classes of service which shall allow customization of features and functions available to stations DO NOT DISTURB All master stations shall be equipped with a privacy open switch to permit any user to put his station in the Privacy mode 22 Aug 2007 Architectural and Engineering Specification ei STENTOFON 4 8 23 4 8 24 When in the privacy mode an incoming call shall sound a unique privacy ring tone at both the initiating station and station being called Call may be answered by momentarily pressing the M button It shall be possible to program selected stations with Privacy Override whereby calls will be heard even if stations are in the privacy mode STATION NUMBERING System shall have a true flexible numbering plan feature whereby any number from 0 to 999999 may be assigned to stations or feature codes Dialling between remote exchanges shall be transparent System shall be factory programmed with an auto load numbering plan of up to 650 separate numbers that may be changed on site as required It shall be p
15. local log files software and configuration The Security Audio and Building Communication Node shall support optional FLASH cards with at least 4 GByte of memory in order to add future services PROM memory shall not be used for storing software or configuration Note An IP environment is a dynamic environment which requires regular updates of the servers to support the latest technologies A solution with PROM memory would then demand high operational costs Hard disk drivers HDD shall not be used for storing software and configuration files Note HDD has moving parts and a normal life length of 3 years The Call Capacity of the Security Audio and Building Communication Node shall be above 10 000 calls per hour The phone cards should manage at least 6 phones per card The intercom cards should manage at least 6 intercoms per card There shall be an option of additional audio boards which each has a capacity of minimum 6 programming and audio channels configurable as input or output There shall be an option for additional Input Output boards in the Security Audio and Building Communication Node with at least 8 inputs and 8 outputs The Security Audio and Building Communication Node shall have at least 2 serial ports The Security Audio and Building Communication Node shall have at least 2 Ethernet ports The Security Audio and Building Communication Node shall have a capacity of up to 30 channels for interconnection to othe
16. non selective radio systems One channel shall be equipped with relays and opto couplers for non selective radio keying and control Both channels shall have filter for the 40 kHz data carrier used in display stations that might cause amplifier overheating on common PA systems Audio input level shall be 5 mV 1 5 V Audio output level shall be 0 7 V Input and output impedance shall be 600 Ohm Shall be powered from 24 V on the Power Distribution Board if relays are used Current consumption shall not exceed 20 mA with both relays active Board shall be fastened to mounting rail in the intercom exchange The STENTOFON FBSAR board for AlphaCom type 9505 000 complies with the above specifications Dimensions are W x H 100 x 100 mm 3 9 x 3 9 inch 44 Aug 2007 Architectural and Engineering Specification ei STENTOFON 5 2 8 MICROPHONE AMPLIFIER FOR DYNAMIC amp ELECTRET MIC MADER A This board shall be used for two way communication through external loudspeaker B It shall be possible to make announcements by use of a dynamic or electret microphone C It shall be possible to use the microphone s On Off button to activate pre programmed loudspeaker zones for announcement D The RCO input driver and relay must accept both high and low activation input selected by a switch The microphone level must be adjustable It must be possible to select bass boost by a switch Shall be powered from 24 V on the Power
17. 125 x 50 mm 10 4 x 5 0 x 2 4 inch 45 Aug 2007 Architectural and Engineering Specification ei STENTOFON 6 ANNEXA 6 1 REFERENCES Ref 1 Stentofon Network Design Guide 2006 Ref 2 Owen D D and RS Means Engineering Staff Building Security Strategies amp Costs Reed Construction Data Kingston MA 2003 Ref 3 Craighead G High Rise Security and Fire Life Safety Elsevier Woburn MA 2003 46 Aug 2007 Architectural and Engineering Specification ei STENTOFON 6 2 STATION TABLE EXAMPLES 6 2 1 CONVENTIONAL non IP STATIONS This table can be filled in to indicate station ID and relationship between stations peripheral cabinets system cabinets and network backbone SECURITY AUDIO AND BUILDING STATION PATCH CABINET ID COMMUNICATION NODE ID f Network Cabinet Room Segment VLAN 6 2 2 IP STATIONS This table can be filled in to indicate station ID and relationship between stations cabinets and network backbone SECURITY AUDIO AND BUILDING STATION PATCH CABINET ID COMMUNICATION NODE ID e Network Network 47 Aug 2007 Architectural and Engineering Specification STENTOFON 48 Aug 2007
18. 15 V 24 V and 32 V C All power outputs shall be fuse protected by 1 A D Board shall be fastened to mounting rail in the intercom exchange The STENTOFON PDB board for AlohaCom type 9971 000 complies with the above specifications pee Dimensions W x H 130 x 100 mm 5 7 x 3 9 inch NOTE PDB can not be used in AlphaCom E7 43 Aug 2007 Architectural and Engineering Specification ei STENTOFON 5 2 6 o mm D RELAY BOARD MRBD Shall be used where relay control is needed to activate devices such as alarm bells door locks and CCTV camera control from an intercom system The board shall be equipped with 6 relays with dual change over contacts The relays shall be activated by programmed general output ports in the intercom exchange by a RIO unit or other general outputs in the system The RCOs shall be triggered on low or high level input selected by switches The relays shall be powered from 24 V on the Power Distribution Board PDB Current consumption shall not exceed 60 mA with all relays active The board shall be fastened to mounting rail in the AlohaCom exchange The STENTOFON MRBD board for AlohaCom type 9970 200 complies with the above specifications I 0D nim go Dimensions are W x H x D 100 x 100 mm 3 9 x 3 9 inch FILTER BOARD AND SPEECH ADAPTER WITH RELAY FBSAR This board shall include two audio channels to act as a galvanic interface between the intercom exchange and external PA or
19. 24 4 8 27 CALL REQUESTS TO MULTIPLE MASTER GIATIONGS nene ne mre rese rie serere pases spere rennen 24 4 8 28 TRANSFER OF CALL REQUES TS tero tha spina pee xk s Yu Eu Sea a Yu RENERT NENNEN CY xk EYx REENEN NEE 24 4 8 29 TRANSFER OF STANDARD CAUSE 24 4 8 30 CAMP ON BUS MEER 24 4 8 31 TEXT CALL BACK MESSAGE 24 4 8 32 VOICE GALL BACK MESSAGE E 24 4 8 39 CON MR p m 25 4 8 34 CALL REQUEST TIRANGSEERDRESET sensre serere sere re tre se ree se re sre peres serere ren 25 4 8 35 SOFTWARE PROTEGTIQOD EE 25 4 8 36 EMERGENCY ALARM CAL 25 4 8 37 WAKE UP REMINDER CAS 25 4 8 38 FAULT ALARM LOGGING EE 25 4 5 39 ALARM OVERRIDE 26 RS ee ter CERN CRT 26 4 8 41 HOTLINE e EE 26 4 8 42 EVENT HANDLING EE 26 49 SYSTEM OPERATION 26 491 MASTER TO MASTER AT WEE 26 4 9 2 CALL FROM SECURITY SUBSTATIONS TO CONTROL ROOM MASTER STATION 26 4 9 3 CALL FROM A CONTROL ROOM MASTER STATION TO ANY OTHER STATION eem RH mmm 27 4 9 4 GROUP CALL FROM A CONTROL ROOM MASTER STATION 27 4 9 5 PROGRAMMING BUTTONS ON THE CONTROL ROOM MASTER STATION een nemen 27 4 9 6 CONTROL DESK PC MANAGING PROGRAM 27 5 eldlu lpeetem e O 28 E STATIONS EE 28 5 1 1 STANDARD MASTER GIATIONS nr nro nonor on
20. 5 inch Required back boxes flush mount type 6297 00 or surface mount type 6298 00 7060 1020 38 Aug 2007 Architectural and Engineering Specification ei STENTOFON TAMPER AND VANDAL PROOF SUBSTATIONS A Shall be used where vandalism is a threat to the equipment and where advanced safety solutions are required Shall have one call in button pre programmed for call request to a master station Shall have internal preset volume control Shall include a red Station on LED moo IH The five button version shall in addition have Cell light toggle button Entertainment source selector in 8 steps Entertainment program display Entertainment volume up down buttons Shall have built in tamper switch with tamper alarm and warning for station and line fault Shall be possible to arm for button touch alarm scream alarm and time out alarm gt af Shall include two programmable general purpose outputs and three inputs Shall include an electret microphone with 100 300 mV output and sensitivity 65dB 1 KHz c Shall include a preamplifier with 1000 ohm output impedance and greater than 40 dB signal to noise ratio Frequency response of input and output shall be 200 to 10 000 Hz Output power shall be 1 W in a built in loudspeaker Shall include outputs for redundant light signalling system e Ser zA Station front shall be in 2 5 mm stainless steel suitable for wall mounting in flush mount back box with 6 t
21. Audio and Building Communication Node 14 Aug 2007 Architectural and Engineering Specification ei STENTOFON J 4 1 2 A B C The Security Audio and Building Communication Node shall be able to connect Analogue telephones Master stations Control room station Dual Display station Substations IP substations IP master stations SIP based telephones SECURITY AUDIO AND BUILDING COMMUNICATION NODE SUBSCRIBER BOARDS All subscriber boards shall be identical and interchangeable Malfunction of one subscriber board shall not affect more than six stations Malfunction of one wire to a subscriber board shall not affect more than one station 42 CAPACITY OF SECURITY AUDIO AND BUILDING COMMUNICA TION NODE A B The Security Audio and Building Communication Node shall have a general processor with minimum 200 MHz frequency The Security Audio and Building Communication Node shall have a media processor DSP with minimum 200 MHz frequency and above 1 000 MIPS in performance The RAM on the Security Audio and Building Communication Node shall be higher than 100 MByte The Security Audio and Building Communication Node shall have at least 1 MByte of Non Volatile RAM that will survive re start and power outage Important information such as time xxx shall be stored in the Non Volatile RAM The FLASH memory on Security Audio and Building Communication Node shall be higher than 32 MByte for storing of
22. Audio and Building Communication Node shall be protected with a login procedure F Software packages that are installed in the Security Audio and Building Communication Node shall be verified with a digital signature in order to prevent downloading and installation of tampered software and reducing risks of viruses G The system shall at least support the following IP standards IPv4 Internet Protocol version 4 TCP Transmission Control Protocol UDP User Datagram Protocol SNMP Simple Network Management Protocol Syslog System logging HTTP HyperText Transfer Protocol XML eXtensible Markup Language NTP Network Time Protocol SIP Session Initiated Protocol RTP RTCP Real Time Protocol Real time Transport Control Protocol DiffServ Differentiated Services IP ToS IP Type of Service 48 STANDARD SYSTEM FEATURES 4 8 1 MASTER CALLS A Acall shall be placed from any master station to any other station in the system unless specifically blocked by dialling the appropriate number of the desired station or using one of the direct access buttons B Either party can cancel call by pressing the C button C Master stations with graphic displays shall provide individually programmable menu functions and subscriber directory with alohanumeric search for numbers names 4 8 2 SUBSTATION CALLS A Each substation shall be programmed to call a specific master station by pressing a button 19 Aug 2007 Architectural an
23. It shall be possible to dispatch calls between the private radio system and the PBX system the public telephone system as well as intercom stations lt shall be possible to transfer private radio calls from an intercom station to the PBX and public telephone system FIRE ALARM The Security Audio System shall be able to integrate with lt product name gt Fire Alarm System The manufacturer shall be able to document installation and references of integration with lt product name gt upon request When a fire alarm is activated the Security Audio System shall automatically establish a call from the control room to the area where the fire alarm was generated The guard can then verify with people in the neighbourhood whether this is a valid fire alarm and the severity of the fire The Security Audio and Building Communication Node shall be able to use information from the fire alarm detectors to provide safe automatic voice guided evacuation VIDEO SURVEILANCE The Security Audio System shall be able to integrate with product name video surveillance system The manufacturer shall be able to document installation and references of integration with product name or similar product upon request It shall be possible to associate intercom stations with the active camera to give the guard a listen or talk option using a single touch button It shall be possible to select a camera from the guard intercom station When the guard is in conve
24. Ltd assume no responsibilities for any errors that may appear in this publication or for damages arising from the information in it No information in this publication should be regarded as a warranty made by STENTOFON Communications Australia Pty Ltd The information in this publication may be updated or changed without notice Product names mentioned in this publication may be trademarks they are used only for identification 3 Aug 2007 Architectural and Engineering Specification ei STENTOFON 1 GENERAL 1 1 SCOOPE OF WORK A B Scope of work shall include the on site Security Audio and Building Communication Node including all intercom stations The Security Audio and Building Communication Node shall be configured as a part of the Security Management System and provide seamless integration with the following systems Access control intrusion detection and alarm systems Emergency notification audio paging and radio paging Two way radios PBX system and public telephone network Video surveillance systems Fire alarm systems The Security Audio and Building Communication shall be able to be operated as part of the IT operation system including support for Network monitoring servers SNMP Syslog Network time servers E mail notification Remote system programming Remote system upgrade See chapter 3 2 for more details D The system shall be designed around a life cycle concept start
25. O O Security Management Server 1st Generation 2nd Generation 3 Generation Figure 4 Overview Open Integration Points 10 Aug 2007 Architectural and Engineering Specification ei STENTOFON 3 3 2 3 3 5 3 3 6 A B PUBLIC ADDRESS The Security Audio System shall be able to interface lt product name gt Public Address System The manufacturer shall be able to document installation and references of integration with lt product name gt or similar product upon request It shall be possible to dispatch PA calls from the intercom stations lt shall be possible to switch and network the PA calls over the internal network between the Security Audio and Building Communication Node with a minimum bandwidth of 7 kHz The Security Audio and Building Communication Node shall be able to interface up to 6 PA zones TWO WAY RADIO The Security Audio System shall be able to interface lt product name gt Private Radio System The manufacturer shall be able to document installation and references of integration with lt product name gt or similar product upon request lt shall be possible to set up multiple intercom system to listen to a radio group lt shall be possible to talk into the radio channels from the intercom stations
26. RM MANAGEMENT SY EE 12 EXTERINALTEEEPHOBNE NE EW ORI ee merisead EEEE RENE NE EERE SE ENERE i 12 VOIP TELEPHONE PDAS AND e 12 REQUIREMENTS OF DAILY SECURITY ROUTINES sscsssssesssssessssssssssecssssesssseessseeessteeesseeeen 13 SYSTEM REQUIREMENTS eegene 14 GENERAL SYSTEM PROFILE sessssesssssessssseesssesssssessssessstesssseesssistssesrssestssisesstessssnensneeesseses 14 SECURITY AUDIO AND BUILDING COMMUNICATION NODE PROFILE eese 14 SECURITY AUDIO AND BUILDING COMMUNICATION NODE SUBSCRIBER BOARD 15 CAPACITY OF SECURITY AUDIO AND BUILDING COMMUNICATION NODE 15 SYSTEM MONITORING amp LOGGING sseteettett ttt ttti 16 LINE amp BOARD Vis ING EEN 16 AH See EE 16 SYS IEM MONITORING EE 17 SYSTEM MAINTENANCE AND CONFIGURATION PROGRAMMING s 17 NETWORKING ttn tte ot 18 NETWORKING BETWEEN SECURITY AUDIO AND BUILDING COMMUNICATION NODES nninnnannnnnnsnnnnnnsnnnnrnsnrrenn 18 CLUSTERING OF SECURITY AUDIO AND BUILDING COMMUNICATION NODES eese 18 AUDIO EUNCTIONS tette tte ttt ttt tte ttti 18 IP SERVICES AND SECURITY ssss iiisssssesriierssseetriirrssstrirerssenerrrrrssetnrrrrrssentrrrrrssantnrrrrrssnnr rns 19 STANDARD SYSTEM FEATURES tente 19 JredBznresiss c n 19 wee TION CALS oso uu 19 DIRE GT ACCESO KEYS DAK 20 ned c EE 20 CRO
27. TV control IP Substation Entry Access IP E Substatior IP Substation Figure 2 A generic separation of Security Audio network and Administration network There shall be a dedicated IP network for the building security application security audio CCTV access control etc This security IP network shall be separated from the other IP networks in the building Note The supervision and fault handling of hardware is often undertaken by the IT department That means that if there is a Security Audio and Building Communication Node or a station which are not functioning correctly the IT department will handle the issue The security functions of the building can then focus on the security application and not whether or not there is a fault in the system The Security Audio and Building Communication Node shall have a separate IP management interface allowing integration to the IT administration network and application The Security Audio and Building Communication Node shall be able to integrate into the IT network monitoring servers by means of SNMP and syslog It shall be possible to monitor and log the status of the Security Audio and Building Communication Node and all Audio Stations from the IT administration network The software on the Security Audio and Building Communication Node and all IP Audio Station shall be able to be upgraded using a standard Web browser It shall be possible to configure and program the Security Audio
28. UPE GALI sane 20 GiisrazlREIICICsA Aai 20 AUTOMATIC SEARG 20 REPLY A ET iz M P 21 DUPLEX MANUAL el a VC MN 21 REMOTE CONTROL FUNCTIONS 21 ge REI SEES HR 21 TONE SIONAL eae P eadenhens 21 eue acr zu AR HE 21 GALL FOLD INQUIRY S TRANS FEM E 21 STANDARD CONFERENOE f T e Mn 21 aims iECSB ILES l1m iec 22 OPEN DUPEECODNFERENGEw omit S ORT nT en TOT Ros ua Sc IN REO UE MULA ne ton None eer rece err emer EU 22 PRIORITY AND CLASS OF c 1 9 2 EET 22 peg CUE Slog LN la APP T a 22 STANON NOUM BERIN G EE 23 MUSIC DISTRIBUTII IN ME 23 INFORMA TION CHANNEL reri se tet REPRINT IET 23 REMOTE SET UP TEE 23 RS TNE S SA E er A E E EE EEE EEE E E E 23 2 Aug 2007 Architectural and Engineering Specification ei STENTOFON 4 8 25 TECHNICAL ALADMG serre se rer retpeseesee serere pere ie pese re se pe sre pe see rre nnne 23 4 5 26 AUDIO ALERT OF TEXT MESSAGE ta ntt dp aav rim sue
29. accessible in front shall have volume override facility Shall go in standby mode to preserve power when no signals are present Shall include set and reset keys for programming and service of the amplifier Impedance level for line monitoring time between tests and error detection limits shall be programmable Shall include monitoring of amplifier and output for automatic change over to standby amplifier Shall be in closed housing complying with IP20 classification finger proof Shall meet IEC65 EN60950 requirements Up to 6 units shall be mounted in a 3U 19 rack The STENTOFON InterGuard IG60 Amplifier type 9971 000 complies with the above specifications lurt amp Guago 0 ata oe lI o nim E E x Dimensions W x H x D 70 mm x 3U x 220 mm 2 7 inch x 3U x 8 6 inch GENERAL PURPOSE AUDIO INTERFACE AGA Shall be used for feeding 16 audio program channels into and or out of the intercom exchange under software control One or two boards in one exchange Shall be fed from any analogue audio program source Shall be used to provide 8 channels for two way speech communication between modules in a multi module system One two or three boards in each module Shall have galvanic isolated inputs outputs via 600 Ohm 0 dB transformers Shall have plug in terminals on the board Shall have individual adjustable sensitivity 100 mV 1 V controllers for all channels Shall have a frequency range of 40 18 500 Hz S
30. amper proof screws Buttons shall be vandal proof capacitive touch type with back light Loudspeaker and microphone grille shall be protected with no penetration barrier The station shall have IP65 front access classification Temperature and humidity range shall be O to 40 32 to 4 104 f 10 85 RH The following STENTOFON Tamper and Vandal Proof Stations comply with the above specifications Do UO ee ee Bee oe 9 CE E E O E E 999999 995929225925 LEL EE EE JE SE SE I eeseeaee eee LSW 7061 000 7063 000 Dimensions W x H x D 128 x 264 x 51 mm 5 0 x 10 4 x 2 4 inch Required back box with anchors flush mount type LBB 7073 76 39 Aug 2007 Architectural and Engineering Specification ei STENTOFON 5 1 9 WEATHER AND VANDAL RESISTANT IP SUBSTATIONS A Weather and Vandal Resistant IP substations shall be designed to deliver CCoIP Critical Communication over IP B The stations shall have a 2 mm stainless steel faceplate which can be fastened to a back box with four tamper proof screws C The loudspeaker and microphone are protected by a tamper and vandal proof grid D The stations have two RJ45 connectors with a 10 100 Mbps switch and can be configured with fixed or dynamic IP addresses The codecs are either standard G 711 or the higher quality G 722 The unit can tag priorities DiffServ ToS at the Ethernet packets and it has acoustic echo cancellation and adaptiv
31. ancel C button Privacy slide switch Variable volume control Shall include 10 true direct access buttons subsets or multiple keystrokes shall not be acceptable Shall include a red Station on LED Shall include a 3 1 6 watt soeaker with 88 dB sensitivity mounted in an acoustic baffle Shall include an electret microphone with 100 300 mV output and sensitivity of 65 dB 1 KHz Shall include a preamplifier with 1000 ohm output impedance and greater than 40 dB signal to noise ratio Frequency response of input and output shall be 300 to 10 000 Hz Output power shall be 1 W Master stations shall be in a modern grey or black plastic housing suitable for desk or wall mounting and have a 2 m 6 foot cord with plug Master stations may have a lightweight handset with coiled cord and magnetic hook switch for confidential conversations Master stations may have a two line 16 character information LCD display 28 Aug 2007 Architectural and Engineering Specification ei STENTOFON The following STENTOFON Standard Master Stations comply with the above specifications 7036 210 7034 210 7036 310 7034 310 Basic Handset Display Handset Display 168 x 75x 176 mm 225 x 75 x 176 mm 168 x 75 x 176 mm 225 x 75 x 176 mm 6 6 x 2 9 x 6 9 inch 8 9 x 2 9 x 6 9 inch 6 6 x 2 9 x 6 9 inch 8 9 x 2 9 x 6 9 inch Desk or wall mount Desk or wall mount Desk or wall mount Desk or wall mount 7071 090 7072 090 Display Handset
32. ands free conversation with the person who initiated the page by simply pressing an answer code on any convenient master station in the group System shall allow multiple page reply functions simultaneously The max waiting time shall be programmable DUPLEX MANUAL OPERATION Once a call connection is established normal conversation shall take place in duplex mode whereby each person may talk hands free Each master station shall have a manual simplex button that when used shall control the direction of the conversation press to talk release to listen Momentarily depressing the simplex button shall restore duplex mode REMOTE CONTROL FUNCTIONS Each station port in the exchange shall include 1 RCO Remote Control Output to be freely used for control of external equipment A Relay Board may be required The RIO Remote In Out unit shall be monitored by the exchange for connectivity and is reported as fault of device if disruption occurs VOLUME CONTROLS The volume of each station shall be adjustable by programming the appropriate subscriber board in the exchange either from the station or from PC programming In addition each master station shall have an adjustable volume control Adjustments shall allow a total range of 14 dB to 16 dB Outgoing volume shall be automatically increased by 6 dB when using the simplex key for press to talk TONE SIGNALS All features and functions such as off hook call conn
33. bility to initiate group call shall be restricted to designated stations A station may be programmed for membership in several groups It shall be possible to program up to 100 groups There shall be no limitations to the number of stations in any group It shall be possible to program up to 4 adjacent stations out of a group call so as to eliminate audio feedback The system shall be able to send out several group calls simultaneously There shall be up to 4 levels of priority each group priority shall be programmed to one of 4 call announce chime tones Answer function is done by dialling a code on any station in the called group OVERHEAD PAGING All master stations shall be able to dial or use direct access into one or more voice paging system s for zoned and or department paging over amplified speakers unless specifically restricted through programming AUTOMATIC SEARCH Each station shall have a pre programmed list of actions that can automatically take place when their station is called when they are either busy in private or absent System shall allow call to be automatically rerouted to another station leave a call request initiate a group call etc Each station can have up to 3 different search call numbers 20 Aug 2007 Architectural and Engineering Specification ei STENTOFON 4 8 8 4 8 13 4 8 14 4 8 15 REPLY FEATURE A person hearing a page or group call shall be able to begin an immediate normal h
34. control inside station May include 4 direct access keys DAK May include a two lines 16 character information LCD display The display may have back light powered from a separate supply shall include a red Station on LED Shall include a 3 1 6 W speaker with 88 dB sensitivity mounted in an acoustic baffle Shall include an electret microphone with 100 300 mV output and sensitivity 65dB 1 KHz Shall include a preamplifier with 1000 ohm output impedance and greater than 40 dB signal to noise ratio Frequency response of input and output shall be 300 to 5 000 Hz Output power shall be 1 W Shall have a Mylar covered aluminium front plate for wipe down sterilisation Surface must be resistant to common washing and sterilisation detergents Must be wall mounted in flush or surface mount back box The following STENTOFON Operating Room Stations comply with the above specifications TTT gae Oste GER uni ag WR iol E panon 6036 600 7036 600 Flush mount back box 0602 000 Surface mount back box 0603 000 Dimensions W x H x D 125 x 280 x 66 mm 4 9 x 10 9 x 2 6 inch 32 Aug 2007 Architectural and Engineering Specification ei STENTOFON 5 1 5 INDUSTRIAL MASTER STATIONS LIGHT INDUSTRIAL MASTER STATION A Shall have access to all features in the exchange B The light industrial master station shall be splash proof and designed for humid dirty and outdoor conditions C The exterior casing
35. cribers 80 subscribers 138 subscribers Security Audio and Building Communication Nodes in the STENTOFON AlphaCom E series comply with all specifications in this document A The system shall support dual networking for stations 2 pair wiring and IP based stations B The exchange shall be backward compatible with older systems and equipment of the same brand C The system shall be capable of automatic duplex hands free operation without the use of handsets at both the initiating and receiving station D System capacity shall include at least one Security Audio and Building Communication Node cabinet wired and equipped for stations numbers and speech channels See details in Annex A E Each exchange system shall be expandable to stations by adding plug in boards and additional Security Audio and Building Communication Node modules F Thecentral exchange shall include at least simplex conference channels at least programmable group calls per exchange and global group calls in network configuration Note to specifier indicate size and capacity of exchange G Iftemporarily blocked and a high priority call is initiated the system shall automatically disconnect the call with the lowest priority and setup the call with the higher priority H The exchange shall support IP based audio communication without additional hardware l There must be an interface between the conventional and the IP network infrastructures in the Security
36. d Engineering Specification ei STENTOFON 4 8 3 4 8 5 JE IE ei 1H Q 4 8 6 4 8 7 Pressing button on substation shall provide call request verification by blinking LED on station and giving voice message with optional voice board A substation call request call shall be identified on a display master station with text message or flash an associated LED and sound a unique tone on a CRM type control room master station DIRECT ACCESS KEYS DAK All Desk Master stations shall include 10 direct access keys programmable for single button speed dialling to other stations to execute features or to get access to telephone lines Dual Display Master stations shall be capable of at least 20 direct access key functions Control room master stations type CRM shall have direct access key modules available in 48 button size each station capable of up to 96 direct access keys Station user shall easily program direct access keys at any time ALL CALL All master stations shall be able to initiate an all call page to all other stations in the system lt shall be possible to remove stations through programming from receiving all call and restrict any station from initiating an all call Selected stations shall receive all call announcements at full volume regardless of station volume setting GROUP CALL All master stations shall be able to initiate selective paging to predetermined groups of stations in the system A
37. e in the network shall have support of E1 T1 and IP infrastructure for networking D All features of the Security Audio and Building Communication Node shall be operational across the total network High Priority calls shall release lower priority calls if all channels are occupied The Security Audio and Building Communication Node shall not delay any audio flow through itself with more than 5 ms when it is serving as a transit switch G Alternative routing of calls shall be supported 4 5 2 CLUSTERING OF SECURITY AUDIO AND BUILDING COMMUNICATION NODES A It shall be possible to set up up to four Security Audio and Building Communication Nodes as an exchange cluster in order to add more capacity for more legacy subscriber extensions B The exchange cluster shall be managed as one exchange enabling easy configuration and management C The signalling and audio communication between the Security Audio and Building Communication Nodes in the cluster shall go over IP D All features shall be operational across the Security Audio and Building Communication Node in the cluster 4 6 AUDIO FUNCTIONS A Malfunction of one speech channel shall not affect operation of the system B Every speech channel shall include compression circuits to automatically control and limit sound volume audio distortion and clipping during conversation C Audio power output to each station shall be adjustable up to 1 Watt D Frequency response for bo
38. e jitter buffer G The station can be supervised from the IP network and it can be configured from a central exchange or by using the integrated web server H The unit has one relay output l The station is delivered in two versions With one mushroom or stainless steel button for mounting in flush mount 3 gang back box With one or two tamper proof stainless steel button s for mounting in flush mount back box 8098 100 or on wall back box 8098 000 The following STENTOFON Weather and Vandal Resistant IP Substations comply with the above specifications 77775 8041100 8051 000 Dimensions 8041 100 W x H x D 92 x 180 x 54 mm 3 6 x 7 1 x 2 1 inch Dimensions 8051 000 W x H x D 114 x 160 x 63 mm 4 5 x 6 3 x 2 5 inch 40 Aug 2007 Architectural and Engineering Specification ei STENTOFON 5 2 OPTIONS 5 2 1 A QU un OW 2 ch L M N O 60 W AMPLIFIER The amplifier shall be used for distribution of audio for information calls background music and evacuation messages Audio input shall be an intercom exchange subscriber line and or other audio sources The intercom wire input shall have priority over the AUX input The output shall be 60 W on a 100 V line There shall be line monitoring on the loudspeaker output Status indicators in the front shall show error type line error amplifier error load error overheating GND fault and overload Volume and bass treble control shall be
39. e synchronized in time with the central network clock Note In an IP network a failure in on sub system can spread across the network in a matter of milliseconds It is therefore essential to synchronise the clocks on all equipment in order to find what fault that happen first thus finding what started the failure situation NTP is able to synchronize the clocks across the network with accuracy less than 10 milliseconds 4 3 3 SYSTEM MONITORING The system shall provide the following important system status information for monitoring A G H General node information Node states HW configuration SW configuration HW identity MAC address Station status List of all stations Status per station Status internal networking List of AlphaNet links Status per link Network delay for VoIP AlphaNet links Status external VoIP networking SIP List of SIP trunks with destination address Number of licenses pr SIP trunk List of SIP users with destination address Status per user VoIP audio statistics List of VoIP links Connections Packet loss Network delay Other VoIP statistics The Security Audio and Building Communication Node shall have a Web server where it is possible to read all important system status information The Security Audio and Building Communication Node shall be able to provide important system information over SNMP The Security Audio and Building Communicati
40. ection busy call forward all call group call etc shall be accompanied or preceded by a distinguishable tone All group call tone signals shall be programmable and tones shall be harmonic and undistorted lt shall be possible to customize and change the length and frequency of all group call tones MICROPHONE MUTE During conversation a person shall be able to momentarily block the microphone on own master station by holding down one button the 0 key CALL HOLD INQUIRY amp TRANSFER Once a call is connected it shall be possible to place the call on hold by pressing one button digit 2 dialling and conversing with a third party switching back and forth or transferring the call by pressing one button digit 3 STANDARD CONFERENCE It shall be possible to establish and or join a conference by dialling a standard or programmable digit code It shall be possible to include any number or all stations in a conference 21 Aug 2007 Architectural and Engineering Specification ei STENTOFON 4 8 18 A 4 8 19 A The system shall allow 50 different simultaneous conferences Voice control shall be manual press to talk release to listen In a standard conference intercom and paging announcements shall temporarily interrupt the conference One person at a time shall talk in an individual conference Stations can be programmed with the ability to override and take control of talking into or feeding the conference
41. ergency conditions The following system spares shall be made available locally within 8 hours of notification _1_ Central exchange spare parts kit _1_ Desk master station 1 Tamper resistant substation _1_ Wall master station Note to specifier Indicate items needed 6 Aug 2007 Architectural and Engineering Specification ei STENTOFON 3 SYSTEM OVEREVIEW 3 1 AUDIO STATIONS Master Station Security Audio Control Room 1 Node A Master Statior Star wire and or IP Network Substation Ly zl 2 WLAN PDA WLAN PDA 4 W Voice Client Master Statior Voice Client SE Ze IP Substation r3 Star wire and or IP Network Substation Sremo AphaCam E7 Security Audio Node B IF Master Statior Substation Control Room 2 Figure 1 A generic building with Integrated Security Audio Network The Integrated Security Audio Network in a generic building shall have Security Voice stations in many of the functional locations in the building see Ref 2 Owen etc The station type shall be selected according to use and environment as specified in the list below In most rooms which need special security attention it is recommended that there should be at least two stations One master station in the operating area of the room One alarm substation at the door on the inside of
42. hall contain a red green amber indicator LED Shall have coded connector to ensure correct positioning in the module Shall be a Hot plug in plug out device 41 Aug 2007 Architectural and Engineering Specification ei STENTOFON The STENTOFON AGA board for AlohaCom type 9303 001 complies with the above specifications m r om S TAS Dimensions are W x H x D 263 x 230 x 10 mm 10 3 x 9 x 0 4 inch STORED VOICE PLAYBACK BOARD ASVP This board shall be used for pre recorded voice messages in the intercom system English French German Norwegian Swedish Danish and Finnish messages shall be available Other languages shall be delivered on request Standard alarm messages shall be available on the boards with English Norwegian German and Swedish speech messages It shall be possible to store 9 different alarm messages It shall be possible to order custom specified messages or to customize messages with special programming tool Up to 30 minutes of digital speech shall be stored in FLASH memory It shall be possible to play back 8 channels simultaneously Speech coding shall be 64 kbit sec ADPCM Audio bandwidth shall be 300 6 800 Hz Sampling rate shall be 16 kHz Shall have LED at the front to indicate status Shall be mounted in an empty exchange card slot Shall be a Hot plug in plug out device The STENTOFON ASVP board for AlohaCom type 9304 0XX complies with the above specifications
43. hen answer the call by pressing a key The Security Audio System shall be able to initiate a scream alarm when it is high noise in an area It shall be possible to associate intercom stations with alarm calls The guard is given a single key touch listen and talk option to the area where the alarm was initiated EXTERNAL TELEPHONE NETWORK The Security Audio and Building Communication Node shall be able to interconnect with a PBX system and the public telephone systems The interconnection to external telephone systems shall be done by Analogue telephone lines FXO ISDN BRI ISDN PRI Session Initiation Protocol SIP VoIP trunking The Security Audio and Building Communication Node shall support up to 30 channels to the external telephone systems Calling number presentation shall be supported between the PBX system and Security Audio System The Security Audio and Building Communication Node shall be able to share a private number plan with the external PBX system The Security Audio and Building Communication Node shall have possibility to undertake SIP based trunking to Cisco Call Manager PBX VoIP TELEPHONE PDAs AND PCs The Security Audio and Building Communication Node shall support standard VoIP telephones using SIP The Security Audio and Building Communication Node shall be able to place calls to PDAs and PCs using SIP The Security Audio and Building Communication Node shall support up to 50 VoIP teleph
44. ing with the needs of users and the organization in which it will be placed regulations and the financial ambitions from there to features and system planning and then to operations system changes and maintenance System shall be capable of adding optional features capacity equipment and interfaces listed in the specifications even if not initially included or shown on the plans 1 2 QUALITY ASSURANCE AND WARRANTY A B C All equipment shall be new in current production and standard products of a manufacturer of intercom equipment Manufacturer shall be certified as complying with the standards of ISO 9001 for quality control Manufacturer shall guarantee availability of parts for a minimum of 5 years from date of shipment If required manufacturer shall be able to demonstrate features functions operating characteristics and clarity of sound to owner System shall include a factory warranty that equipment is free from defects in design material manufacturing and operation Factory warranty period shall be for 12 months from date of shipment Installing communications contractor shall guarantee the equipment connections cabling and installation for 12 months from date of acceptance The manufacturer shall have more than 20 years experience with security audio systems and upon request it shall document comparable installations and references hereof The manufacturer shall upon request be able to docume
45. initiate priority alarm calls to groups of stations in the system Alarm calls shall override all conversations in progress override station volume settings and be heard even if handset is off hook on desk master stations Stations can be exempted from receiving the emergency calls It shall be possible to initiate an alarm call from external equipment and give an automatic voice message 4 8 37 WAKE UP REMINDER CALLS A The system shall allow up to 200 separate automatic date and time calls that will cause individual stations to ring at preset times This wake up time is entered at the selected station itself The duration and number of rings shall be programmable After initiation dialling a digit or lifting the handset shall cancel the ring 4 8 38 FAULT ALARM LOGGING A The system shall be able to archive activities fault and alarm conditions via a Syslog file Fault conditions within the system can be faulty boards wiring or software External alarm conditions input through the intercom system will be printed as time and source of alarm Calls between intercom stations in the entire system will be logged It shall be possible to view the contents of the log file via AlohaWeb It shall be possible to use an OEM Syslog viewer to send the logged events to an external IP or e mail address for remote monitoring of the system 25 Aug 2007 Architectural and Engineering Specification ei STENTOFON 4 8 39 4
46. itectural and Engineering Specification ei STENTOFON 4 8 33 GROUP HUNT A B C D The system shall allow programming of multiple Hunt groups whereby calls to a group number will search and connect to the first available station in the group The feature may be programmed to have a rotational or fixed start point Feature shall allow substation calls to be directed to a primary master but if it is busy search for an available master in the group Group Hunt shall allow automatic transfer on busy 4 8 34 CALL REQUEST TRANSFER PRESET A Stations shall be allowed to automatically divert call request calls to pre selected station or group of stations by dialling a standard or programmable digit transfer code then the station number or group number 4 8 35 SOFTWARE PROTECTION A B All software and programmable information including customer on site changes shall be retained in FLASH memory When instaaling new software on the Security Audio and Building Communication Node the software file packages shall have a digital signature The digital signature shall be checked in order to verify that no one has tampered with the software from the manufacturer It shall be possible to store the program on a PC using AlphaPro and also be able to download the contents of the FLASH memory as a file for troubleshooting via AlohaWeb 4 8 36 EMERGENCY ALARM CALLS A B C D Selected stations shall be able to
47. l be 10 W in 8 20 Ohm separate 12 VAC 2 A power supply required Frequency response of input and output shall be 500 5 000 Hz Shall have connections for optional handset with microphone impedance 200 600 Ohm Shall include 2 x PG7 and 2 x PG9 glands The following STENTOFON Heavy Duty Industrial Maser Station complies with the above specifications 7086 000 Dimensions W x D x H 160 x 260 x 100 mm 6 3 x 10 2 x 3 9 inch 35 Aug 2007 Architectural and Engineering Specification ei STENTOFON 5 1 6 INDUSTRIAL SUBSTATIONS HEAVY DUTY INDUSTRIAL SUBSTATIONS ONE OR THREE BUTTONS A This industrial substation shall be weather resistant and designed for humid dirty and outdoor conditions B The exterior casing shall be comprised of a chip resistant orange silumin C The stations shall include one large programmable call button D In addition the station may include an M button for speech control and other functions and a cancel C button There shall be preset volume control and always privacy switch inside the station The station shall have a red LED indicator for incoming calls and station in use indication The station shall have an IP65 classification Temperature and humidity range must be 20 50 C 4 122F and 1096 85 RH Shall include a noise cancelling microphone ro mm 2 Shall include a preamplifier with 1000 ohm output impedance and greater than 40 dB signal to noise ratio
48. m requests Time and date for all transfer functions System log level shall minimum include the following information Software errors Hardware errors Line errors Alarms Remote input on off The Security Audio and Building Communication Node shall be able to send the different types of log to multiple remote destinations This destination could be T helpdesk Security control room in the same building Security control room at remote sites System responsible for the Security Audio and Building Communication Node The Security Audio and Building Communication Node shall be able to output the log events to Local file system Syslog Standard used by main IT network monitoring servers and tools E mail SNMP trap standard used by main IT network monitoring servers and tools The system shall be able to perform filtered logging conditioned upon destination like Alarms only The Security Audio and Building Communication Node shall have a web interface where it is possible to retrieve the local log file as well as search and retrieve in the different log files Time synchronization of events among nodes and other systems 16 Aug 2007 Architectural and Engineering Specification J K STENTOFON All Security Audio and Building Communication Nodes in the network shall get time information from a defined NTP server Network Time Protocol All log events shall b
49. n E AEDEP ED AEREA EREDE DEDEDE EEEEEEE SERERE E EEEE Ennn 28 5 1 2 DUAL DISPLAY MASTER STATION dreeges ereeeee ENEE EE EEN ENEE 30 5 1 32 WALL MOUNTS TATIONS EN 31 5 1 4 OPERATING ROOM MASTER STATION 32 5 1 5 INDUSTRIAL MASTER GSIATIONG ccc cccccceccecceccecceeeeeeeeeceeeeceeaeeneeaesaeseeceeceeaeeeeeaecaeeaeseesaeseeaeeaeeaesaesneseeseeaeeaeeaeseeeaees 33 5 1 6 INDUSTRIAL SUBS EA He IC LEE 36 5 1 7 CONTROL ROOM MASTER STATION 37 DNR Se E EC SEH ETC IECH ER H LE 38 5 1 9 WEATHER AND VANDAL RESIGTANTIPGSURBGSTIATIONG II HI meme nm nne menn merenti neret sre perenne 40 MES e e 41 cU MENOR uz E m 41 5 2 2 GENERAL PURPOSE AUDIO INTERFACE AGA isoxtenis canit n raa caa ERE FE Ira bas E e Ege e Gam ecd pU RES Ecos ex REX xad duaCx da ada 41 5 2 3 STORED VOICE PLAYBACK BOARD AS eer See Eege 42 5 2 4 DIGITAL NETWORK EE eeh dee 43 5 2 5 POWER DISTRIBUTION BOARD PDB eegene eege Ee 43 5 2 6 RELAY BOARD EE 44 5 2 7 FILTER BOARD AND SPEECH ADAPTER WITH RELAY EBGAD 44 5 2 8 MICROPHONE AMPLIFIER FOR DYNAMIC amp ELECTRETMICIMAIDERT 45 5 2 9 REMOTE IN OUT CONTROL RIO casicccscnvasesssancveteetecevecevecsadealeetiacetacsawacawarcssdedoiitet Ganecdiasadawessieetee siemens 45 6 ANNEX EEN 46 6 1 REFERENCES nete a e aaen AAE EEEE BE ETE EARE 46 6 2 STATION TABLE ESAMDLES 47 6 2 1 CONVENTIONAL non IP STATION uiuere f otudad aene u ptu deed EE 47 6022 IP SIATIONS EEN 47 STENTOFON Communications Australia Pty
50. nce 200 600 Ohm Shall include 2 x PG9 glands The following STENTOFON Light Industrial Maser Station complies with the above specifications 7082 000 Dimensions W x D x H 160 x 240 x 137 mm 6 3 x 9 5 x 5 4 inch 34 Aug 2007 Architectural and Engineering Specification ei STENTOFON I op nm Ce p e HEAVY DUTY INDUSTIAL MASTER STATION Shall have access to all features in the exchange This industrial master station shall be water and dust proof and designed for humid dirty and outdoor conditions The exterior casing shall be comprised of orange silumin with brushed aluminium front The stations shall include a keyboard with large rubber buttons for dialling buttons 0 9 manual M button for speech control and other functions cancel C button 4 direct access keys DAK There shall be preset volume control and always privacy switch inside the station The station shall have a large red indicator light for incoming calls and station in use indication The station shall have an IP65 classification Temperature and humidity range must be 20 50 C 4 122Ff and 1096 85 RH Shall include an electret microphone with 100 300 mV output and sensitivity 65dB 1 KHz shall include a preamplifier with 1000 ohm output impedance and greater than 40 dB signal to noise ratio Output power to external 20 70 Ohm loudspeaker shall be 1 5 W Output power from built in VOX operated power amplifier shal
51. nt the fulfilment of all certifications 4 Aug 2007 Architectural and Engineering Specification ei STENTOFON 1 3 SUBMITTALS A Shall include an equipment list data sheets system description and block diagrams on equipment to be furnished B Shall include all data necessary to evaluate design function quality and configuration of proposed equipment and system s C Shall include technical manual s relevant to the installed equipment and user manual s related to the use of functions in the intercom system 5 Aug 2007 Architectural and Engineering Specification ei STENTOFON 2 SYSTEM OPERATIONS REQUIREMENTS 2 1 SYSTEM PLANNING The manufacturer shall provide an IP Network Planning Guide see Ref 1 Stentofon 2006 2 2 SYSTEM INSTALLATION TESTING AND TRAINING A B C The system shall be installed by qualified technicians Wiring shall be uniform and in accordance with national and international electric codes and manufacturers instructions All cable runs at the main terminal board and in all junction boxes shall be tagged and identified Installation of the communication systems shall be coordinated with the installation of other related systems such as Local Area Network LAN and external IP network WAN CCTV video switching audio paging radio paging access control two way radio alarm and telephone systems Directory numbers feature codes and special programming shall be documented pri
52. nted and made available to owner System shall be completely tested to assure that the exchange and all components stations speakers and accessories are connected and in working order System shall be pre tested by contractor and certified to function in accordance with plans and specifications System shall be tested in presence of owner s representative Installation contractor shall conduct up to 4 hours of instruction in use and operation of the system to designated owner representatives within 30 days of system acceptance Installation contractor shall conduct up to 4 hours of technical training in programming troubleshooting and service of the system to designated owner representatives within 30 days of system acceptance Contractor shall provide owner with 2 copies of standard factory prepared operation installation and maintenance manuals Contractor shall provide owner with 2 copies of any risers layouts and special wiring diagrams showing any changes to standard drawings if required on project 23 SYSTEM OPERATION AND USAGE A B It shall be possible for owner to print directory number plans for distribution to users Manufacturer shall conduct periodic technical training seminars and make them available to those responsible for on going maintenance of the system 2 4 SYSTEM SUPPORT AND SPARES A B On site maintenance and repair service shall be available locally and within 8 hours of notification for em
53. o call or transfer calls to the forwarded station It shall be possible to redirect calls while at the receiving station Follow Me by dialling a two digit code plus the number of the forwarded station The system shall be able to simultaneously handle up to 100 call forward commands CAMP ON BUSY The system shall include ability to call a busy station or feature hear a busy tone reduced in volume after 5 seconds wait for a preset time and automatically connect when the called station or feature is free Upon connection both parties shall hear the normal connection tone Number of camp on calls in the system shall be unlimited TEXT CALL BACK MESSAGE If the calling party does not wish to remain camped on it shall be possible to place the call in memory and display a call back message on the called party s station by dialling a digit code The message shall be registered on the display It shall be possible to leave up to 9 pre set text messages on the display of the called station The number of call back messages on any one station or in the whole system shall be unlimited VOICE CALL BACK MESSAGE It shall be possible to leave a pre set audio voice message by dialling a voice message code on the initiating intercom station The audio message shall be played back at the receiving station by dialling a two digit code Voice messages require a voice storage board in the exchange see options 24 Aug 2007 Arch
54. on Node shall support SNMP MIB II 44 SYSTEM MAINTENANCE AND CONFIGURATION PROGRAMMING A B C The system shall have an easy to use configuration and programming tool The configuration and programming tool shall have context sensitive online help The configuration tool shall be able to connect to the Security Audio and Building Communication Node over the IP network It shall be possible to perform remote system upgrade of the Security Audio and Building Communication Node using a standard Web browser The upgrade procedure must take less than 2 minutes 17 Aug 2007 Architectural and Engineering Specification ei STENTOFON E It shall be possible to perform remote system upgrade of all IP stations connected to the system Note An IP environment is a dynamic environment which requires regular updates of the servers to support the latest technologies F System configuration and database shall be possible to back up and restore via a standard Web browser 4 5 NETWORKING 4 5 1 NETWORKING BETWEEN SECURITY AUDIO AND BUILDING COMMUNICATION NODES A The total system x number of Security Audio and Building Communication Nodes and stations phones shall easily be networked up to 100 nodes sites B The communication signalling and audio communication between the nodes shall be able to take place on IP network with private or public addresses or a mix of the two C Each Security Audio and Building Communication Nod
55. ones and clients The Audio Security Node shall be able to send an e mail notification to PDAs and PCs when an alarm or event is triggered 12 Aug 2007 Architectural and Engineering Specification ei STENTOFON E It shall be possible to include a click to call link in the e mail which will set up a call from the PC or PDA to the intercom that is associated with the alarm or event 3 4 REQUIREMENTS OF DAILY SECURITY ROUTINES The system shall support the following daily security routines A Transfer of responsibility from Guard Station to Central Control Room Shall be done by simple button pressing on Master Station Shall let all calls go to Master Station in Central Control Room B Transfer of responsibility from Central Control Room 1 to Central Control Room 2 for example by time of day or weekend Shall be done by simple button pressing on Master Station OR Shall be done by pressing of buttons on web interface C Simple analysis of alarms every 4 hours It shall be possible to print and read directly all alarms for the last 12 hours 13 Aug 2007 Architectural and Engineering Specification ei STENTOFON 4 SYSTEM REQUIREMENTS 41 GENERAL SYSTEM PROFILE 4 1 1 SECURITY AUDIO AND BUILDING COMMUNICATION NODE PROFILE The Security Audio System shall be able to provide communications both under normal circumstances and in emergencies Ref Craighead 2003 AlphaCom E7 AlphaCom E20 AlphaCom E26 36 subs
56. ons or pressing the direct access key programmed for the actual group This shall sound an alert tone and allow paging to all stations in the group There shall be no limitation to the number of stations in a group Group calls shall have priority over other conversations in progress PROGRAMMING BUTTONS ON THE CONTROL ROOM MASTER STATION Direct access buttons on the CRM station shall be easily programmed and changed by the station user Once programmed the button assignments shall remain in memory This feature is valid if CRM is equipped with direct access button modules CONTROL DESK PC MANAGING PROGRAM It shall be possible to use a PC with installed control managing program like AlphaVision to manage all incoming call requests and outgoing calls by pointing and clicking on icons on the site map on the screen The geographical location call status and call priority of any station shall be clearly visible on the map on the screen A call priority list and call log shall be available on the screen Note to specifier Describe other desired operations 2 Aug 2007 Architectural and Engineering Specification STENTOFON 9 EQUIPMENT 5 1 STATIONS 5 1 1 A B ommo STANDARD MASTER STATIONS Master stations shall have access to all features in the exchange Master stations shall include the following controls Dialling buttons 0 9 and Manual M button for speech control and other functions C
57. ossible to change numbers at any time through programming with access codes without any rewiring MUSIC DISTRIBUTION Standard system shall allow up to 6 channels E20 E26 or 2 channels E7 of music to be distributed to all stations Each master station may select a desired channel by dialling a three digit code Music shall be interrupted during intercom calls and return automatically upon completion of the call System shall also include a channel step function 32 additional channels shall be available through optional boards with a total of 38 channels of music possible INFORMATION CHANNEL System shall allow one or more audio channels to be programmed to distribute audio information that is pertinent to the operation of the facility Channel shall be accessed and operated as described for music distribution REMOTE SET UP OF PROGRAMS It shall be possible to individually program stations or groups of stations to receive a channel from a remote master control station TEXT MESSAGES The system shall allow multiple alpha numeric text messages to be stored in queue on each master station The sequence of display shall be based on the priority of each message System shall include 9 absent 9 functional and 3 alarm messages TECHNICAL ALARMS It shall be possible to activate a preset 16 character text message on a selected display master station or group of master stations or activate an audio message on the informa
58. r Security Audio and Building Communication Nodes 15 Aug 2007 Architectural and Engineering Specification ei STENTOFON Q The Security Audio and Building Communication Node shall have a capacity of up to 30 lines for interconnection to legacy PBXes 43 SYSTEM MONITORING amp LOGGING 4 3 1 A B C D 4 3 2 LINE amp BOARD TESTING The system shall automatically test the wiring to legacy station wiring and detect faults within one second The system shall automatically test the link to every IP station every 5 seconds and detect a fault within 10 seconds The system shall have possibility of periodic tone testing of station i e loudspeaker and microphone The system shall have possibility of automatic and periodic board testing SYSTEM LOGGING The system shall provide the following types of log Statistics and call log System log The system log provides technical events for monitoring the health of the system Debugging log The debugging log includes low level system events that software engineers and support personnel use for troubleshooting The statistics log shall provide an event for each function that is requested and executed by the Security Audio and Building Communication Node This shall include events and information like Call detail information including VoIP statistics and time and duration of call Time and details for all call request Time and date for all alar
59. rsation with a station he shall have a single touch option to switch on the camera associated with that intercom station ACCESS CONTROL The Security Audio System shall be able to interface product name Access Control system The manufacturer shall be able to document installation and references of integration with product name or similar product upon request 11 Aug 2007 Architectural and Engineering Specification ei STENTOFON 3 3 7 3 3 8 3 3 9 When a door fails to open using an access card and or access code the station in proximity to the door shall be turned on and the guard can ask what the trouble is The guard shall then be able to open the door by pressing a key There should be an intercom substation next to any door access control By pushing the substation button the visitor will make a call request to a guard The guard shall then be able to be in voice conversation with the visitor by pressing a key The door can be opened by the guard by pressing a key ALARM MANAGEMENT SYSTEMS The Security Audio System shall be able to interface product name Alarm Management System The manufacturer shall be able to document installation and references of integration with product name or similar product upon request There should be a vandal proof intercom station in locked areas like prison cells etc By pushing the station button the locked up person will make a call request to a guard The guard shall t
60. shall be comprised of a flame and chip resistant Bayblend plastic with a UV cured chemical resistant PVC front panel D The stations shall include a keyboard foil with dialling buttons 0 9 manual M button for speech control and other functions cancel C button There shall be preset volume control and always privacy switch inside the station The station shall have a red LED indicator for incoming calls and station in use indication The station shall have an IP54 classification Temperature and humidity range must be 0 50 32 4122 and 10 85 RH Shall include a 3 1 6 W loudspeaker I op nm EL xc Shall include an electret microphone with 100 300 mV output and sensitivity 65dB 1 KHz Shall include a preamplifier with 1000 ohm output impedance and greater than 40 dB signal to noise ratio L Output power shall be 1 W to internal loudspeaker sound pressure at 1 m from internal speaker should be 66 db M Output power to external 20 70 Ohm loudspeaker shall be 1 5 W N Output power from built in VOX operated power amplifier shall be 10 W in 8 20 Ohm separate 12 VAC 2 A power supply required Frequency response of input and output shall be 500 5 000 Hz JM Shall have connections for optional handset with microphone impedance 200 600 Ohm shall include 1 x PG9 and 1 x PG11 glands The following STENTOFON Light Industrial Maser Station complies with the above specifications D t ee l K
61. speaker with 88 dB sensitivity mounted in an acoustic baffle Shall include a gooseneck microphone Shall include a preamplifier with automatic sensitivity adjustment 1000 ohm output impedance and greater than 40 dB signal to noise ratio Frequency response of input and output shall be 300 to 5 000 Hz Output power shall be 1 W Shall allow up to 100 call requests in queue with 256 priority levels and allow multiple parallel masters with transfer of command Front plate shall be in anodized aluminum suitable for flush mounting or desktop mount in back box HANDSET UNIT A Shall be lightweight handset with coiled cord and magnetic hook switch for confidential conversations B The handset should be mounted on an anodized aluminium plate suitable for flush mounting or desktop mount in back box DAK UNIT A Shall be a module with 48 programmable direct access keys each key containing two programmable LEDs B Oneortwo DAK units can be mounted in one console C Front plate shall be anodized aluminum for flush mounting or desktop mount in back box 3 Aug 2007 Architectural and Engineering Specification ei STENTOFON The following STENTOFON Control Room Master Station complies with the above specifications DAK 48 unit type 7006 110 CRM IV unit type 7006 101 Handset unit type 7006 190 125 x 280 x 30 mm 4 9 x 10 9 x 1 2 inch CRM BACK BOXES A Shall be used to mount 1 4 units to form one CRM IV desktop console
62. th input and output shall be a smooth curve through the audio range of 200 10 000 Hz for intercom 200 15 000 Hz on audio program channel E Crosstalk shall be less than 80 dB 1000 Hz and S N ratio shall be 80 dB during conversation F Audio technology used across a network shall support Wideband 7 kHz G 722 Narrowband 3 4 kHz G 711 18 Aug 2007 Architectural and Engineering Specification ei STENTOFON Utilize Adaptive Jitter Buffers Utilize Adaptive Time Synchronization G Audio technology used internally in the Security Audio and Building Communication Node for mixing and switching shall support High Resolution 1 bit audio Hi Fi 40 Hz 18 5 kHz 4 7 IP SERVICES AND SECURITY A The Security Audio and Building Communication Node shall have two independent IP network Ethernet ports in which one can be used as a separate management interface and one can be dedicated to the building security IP network B The Security Audio and Building Communication Node shall not provide IP forwarding between the two IP ports Note If IP forwarding is enabled between the two IP ports the node will be a backdoor between the two networks breaking standard security rules C The Security Audio and Building Communication Node shall have a built in firewall to prevent external attacks D The IP stations shall have a built in firewall to prevent external attacks E The IP stations and Security
63. the room Aug 2007 Architectural and Engineering Specification ei STENTOFON MASTER STATIONS SUBSTATIONS Vandal Resistant Wall and flush mount Location in Large Buildings Standard Desk Light Operation Tamper Industrial Resistant E CD Doors Entrances Stairways Corridors every 15 meter Manual fire alarm points Roof areas Elevators amp elevator entrances Elevator machine rooms Mail and parcel delivery rooms HEVAC amp machine rooms Loading docks every 10 meter Garbage collection areas Electrical switch amp patch rooms Cable patch rooms T rooms Parking entrance exit pay points Parking doors and help points Offices Campuses academic amp business Medical treatment rooms Operating Theatres Supplies amp storage rooms Rest rooms showers and changing rooms Shopping and service areas Guard locations Building control rooms Reception YES m CoD 8 Aug 2007 Architectural and Engineering Specification ei STENTOFON 3 2 INTEGRATION WITH IP IT ADMINISTRATION There should be two IP networks one for the building security audio system and one for the IT administration AlphaWeb M AlphaPrc Network monitoring Administration Network 9 c o Serial Data RS323 Security Audio Node Printer IP Substatior Security Network S TH CC
64. tion channel from remote alarm contacts Each message can be customized and set with a priority level through programming The system shall include 6 inputs E26 E20 or 2 inputs E7 for technical alarms 29 Aug 2007 Architectural and Engineering Specification ei STENTOFON 4 8 26 4 8 27 4 8 28 4 8 29 4 8 32 AUDIO ALERT OF TEXT MESSAGE System shall allow 4 distinct types of audible alert tones to sound at the master station when text messages are activated System shall also allow connection of external alarm indicators lamps buzzers or bells to sound for high priority messages in noisy environments CALL REQUESTS TO MULTIPLE MASTER STATIONS It shall be possible to program up to10 masters to simultaneously receive and display text message call requests from substations When a call is answered at one master station the message shall be deleted at all other stations TRANSFER OF CALL REQUESTS It shall be possible to transfer call requests from substations while allowing standard calls to different master stations by dialling a 4 digit transfer code plus the receiving station number TRANSFER OF STANDARD CALLS It shall be possible to redirect Call Forward all calls to another master station a pager number telephone number or group number by dialling a two digit code plus the redirected number When in the transferred mode only the station selected to receive the diverted calls shall be able t
65. utput impedance and greater than 40 dB signal to noise ratio K Frequency response of input and output shall be 300 to 7 000 Hz r Output power shall be 1 W to internal loudspeaker M Station shall be in a dark grey and black plastic housing suitable for desk mounting and have a 2 m 6 foot cord and plug N It shall be possible to equip the station with a noise cancelling gooseneck microphone The following STENTOFON Dual Display Stations comply with the above specifications 7007 000 7007 010 72 x 140 x 270 mm With gooseneck microphone 2 8 x 5 5 x 10 6 inch 72 x 140 x 2 0 mm 2 8 x 5 5 x 10 6 inch Desktop mount Desktop mount 30 Aug 2007 Architectural and Engineering Specification ei STENTOFON 5 1 3 WALL MOUNT STATIONS MASTER STANDARD A Master station shall have access to all features in the exchange B Master stations shall include the following controls Dialling buttons 0 9 Manual M button for speech control and other functions Cancel C button Privacy switch Variable volume control Shall include a red Station on LED Shall include a 3 1 6 watt soeaker with 88 dB sensitivity mounted in an acoustic baffle Shall include an electret microphone with 100 300 mV output and sensitivity 65dB 1 KHz moo Shall include a preamplifier with 1000 ohm output impedance and greater than 40 dB signal to noise ratio 2 Frequency response of input and output shall be 300 to 5