1. HANA ol NORTH AMERICA User Manual SOLENNE SERIES Wall mounted premix condensing boiler If you smell gas gt DONOT ACTIVATE ANY ELECTRIC SWITCHES TELEPHONES OR ANY OTHER DEVICE THAT MAY GENERATE ELECTRICAL DISCHARGES OR SPARKS OPEN DOORS AND WINDOWS IMMEDIATELY TO CREATE A CURRENT OF AIR THAT WILL RAPIDLY CLEAR THE ROOM gt gt CLOSE ALL GAS TAPS AND VALVES gt CALL FOR PROFESSIONALLY QUALIFIED PERSONNEL FROM A NEAR BY TELEPHONE User instructions ENGLISH USER INSTRUCTIONS BOILER OPERATING INSTRUCTIONS A Make sure that the authorized technician who tested the boiler has documented the test results including gas pressure CO2 flue gas temperature and safety device functions A The installation first start up regulation and maintenance operations must be carried out by qualified personnel Incorrect installation or maintenance can cause damage to property and injury to persons or animals for which the manufacturer will not be held responsible During the installation the technician must carry out the following checks The data on the data plate must correspond to that of the utility networks to which it will be connected gas electricity water The boiler must be regulated according to its designed use and performance The flue gas exhaust and combustion air intake system must be correctly installed and operational The exhaust gas discharge and ventilation syste
2. of the boiler In this respect the reading on the pressure gauge M fig 2 located on the lower part of the boiler must not be less than 1 bar 14 5 psi If there is insufficient water in the boiler the code H20 will flash on the display see fig 1 To bring the system back up to pressure open the external filling tap R fig 2 and use the pressure gauge M fig 2 to check that the system pressure reaches 1 bar 14 5 psi and that the code H20 lights up When the operation is complete close the fill tap Diagnostics Error codes This paragraph contains a list of error codes that the boiler may generate on the display 8 see Control panel together with the relative indications and the operations that the user can carry out to reset the boiler A If the problem re occurs after the following actions have been taken call for service 01_ lonisation block Code E01 lit continuously on the display Check that the gas valve on the boiler and gas meter are open and that there is gas in the mains supply or in the tank Switch off then switch on the appliance using switch 1 see Control panel on the control panel When the error code on the display disappears the boiler will restart If the problem persists Call for Service E02_ Safety Thermostat tripped Code E02 lit continuously on the display Call for Service E03 Flue Gas Thermofuse tripped Code E03 lit contin
3. ctricity and gas supplies connected and consequently the anti freeze function PNA Inc 34 Coffin Ave Brewer ME 04412 P 207 942 3636 F 207 942 3737 www pensotti pna com
4. ght the burner every time there is a demand for room heating or domestic hot water the functioning is signalled by the symbols m Regulating the heating temperature The heating temperature is regulated by knob 2 see fig 1 e Rotating the knob counter clockwise reduces the temperature e Rotating the knob clockwise increases the temperature e range of temperature settings for the central heating runs from a minimum of 86 F to a maximum of 176 F or in the case of low temperature operation from a minimum of 77 F to a maximum of 138 F USER INSTRUCTIONS m D H W temperature control The domestic hot water temperature is regulated by knob 3 see Control panel e Rotating the knob counter clockwise reduces the temperature e Rotating the knob clockwise increases the temperature e The range of temperature settings for the domestic hot water runs from a minimum of 95 F to a maximum of 160 F Topping up the system with water The water pressure in the central heating circuit must be checked during the entire period of operation
5. hing numbers on the display 8 see error codes If code H20 appears on the display 8 this denotes that there is no water in the boiler Consequently fill the system as described in section Filling the system m SUMMER mode To switch boiler operation to SUMMER mode press button 6 see fig 1 The boiler will only work for the D H W system The SUMMER mode setting of the boiler is Fig 1 signalled by the symbol lit continuously on the control panel The automatic ignition system will light the burner every time there is a demand for domestic hot water In this case the symbol ES on the control panel will flash m WINTER mode To switch boiler operation to WINTER mode press button 6 see fig 1 The boiler will only work for the central heating system The WINTER mode setting of the boiler is signalled by the symbol lit continuously on the control panel The automatic ignition system will light the burner every time there is a demand for room heating In this case the symbol on the control panel will flash m SUMMER WINTER mode To switch boiler operation to SUMMER WINTER mode press button 6 see fig 1 The boiler will work for both central heating D H W systems The SUMMER WINTER mode setting of the boiler is signalled by the symbols lit continuously on the control panel The automatic ignition system will li
6. ms must comply with the requirements of national and local standards regardless of whether the boiler is installed indoors outdoors or in its own cabinet see section Reference standards General warnings gt gt If there is any doubt as to whether the appliance has been tested by an authorised technician do not attempt to start it All maintenance and gas conversion operations MUST BE CARRIED OUT BY PROFESSIONALLY QUALIFIED PERSONNEL registered in accordance with current legislation Make sure that the requirements relating to the air intake and ventilation of the room in which the boiler is to be installed have been complied with The boiler is fitted with an antifreeze system If the boiler is installed in a location where there is a risk of freezing the anti freeze system will only come into operation if the power is on and the gas supply valve is open the frost protection is active even with the ON OFF switch in OFF position The manufacturer will not be held responsible for damage to the boiler caused by non compliance with this instruction Should any part of the boiler freeze up do not attempt to light it under any circumstances but instead call a qualified service company immediately The appliance s combustion system must be checked every one year This check includes testing the efficiency of the boiler and must be carried out by authorized personnel possessing the qualifications as required by current law Do n
7. ot obstruct the ventilation openings in rooms where there are gas burning appliances installed boiler cooker etc USER INSTRUCTIONS If you smell gas gt DONOT ACTIVATE ANY ELECTRIC SWITCHES TELEPHONES OR ANY OTHER DEVICE THAT MAY GENERATE ELECTRICAL DISCHARGES OR SPARKS gt OPEN DOORS AND WINDOWS IMMEDIATELY TO CREATE A CURRENT OF AIR THAT WILL RAPIDLY CLEAR THE ROOM gt CLOSE ALL GAS TAPS AND VALVES gt CALL FOR PROFESSIONALLY QUALIFIED PERSONNEL FROM A NEAR BY TELEPHONE Boiler controls Control panel LEGEND ON OFF SWITCH HEATING TEMPERATURE CONTROL KNOB D H W TEMPERATURE CONTROL KNOB D H W TEMPERATURE DISPLAY BUTTON KEEP PRESSED FOR 5 SECONDS TO DISPLAY OUTSIDE TEMPERATURE ONLY WITH OPTIONAL OUTDOOR SENSOR SERVICE BUTTON SUMMER WINTER OR SUMMER WINTER MODE SELECTION BUTTON TERMINAL BOARD FOR EXTERNAL WIRING TEMPERATURE ERROR CODE AND OPERATING STATUS DISPLAY Penn 110V 60Hz Fig 1 USER INSTRUCTIONS Starting up the boiler e Open the gas Isolation valve located under the 8 boiler e Switch on the boiler by placing the ON OFF switch 1 in the ON position see Control panel e The boiler will light automatically with the 0 0 0 WINTER mode selected and room thermostat connected e Check that there are no flas
8. uously on the display Call for Service h2o Water Pressure Switch tripped Code H20 lit continuously on the display Check the water pressure in the central heating circuit The reading on the pressure gauge M see fig 2 located on the lower part of the boiler must not be less than 1 bar Ifthe pressure is less than 1 bar 14 5 psi top up the system as described in paragraph Filling the system The boiler will restart automatically If the problem persists Call for Service USER INSTRUCTIONS E05 Heating Sensor malfunction Code E05 lit continuously on the display Call for Service E12_ D H W Storage Cylinder Sensor Malfunction Code E12 lit continuously on the display Call for Service E16 Electric Fan Malfunction Code E16 lit continuously on the display Call for Service E22_ Parameter programming request Code E22 lit continuously on the display Call for Service E35_ Flame Detection Malfunction Code E35 lit continuously on the display Call for Service E42_ Fan Speed P C B malfunction Code E42 lit continuously on the display Call for Service NOTE If the boiler is to be left unused for a long period of time the user must do one of the following Make the boiler safe by disconnecting all the power supplies electricity and gas and draining the heating system and the condensate trap Leave the boiler in standby leaving the ele
Download Pdf Manuals
Related Search
Related Contents
Manual de instrucciones Miele G 4760 SCVi Muvit MUPRBKCGTL2077 mobile phone case Document PDF Viagrow V300GAPOT ROOT POT PLANTER Instructions / Assembly Symantec™ Server Management Suite 7.5 SP1 powered by Altiris cf. Habitat Actualité n° 133 Bedienungsanleitung Manuel d`utilisation BK-DVD-7895TV SOSP Copyright © All rights reserved.