Home

HWg-STE plus MANUAL

image

Contents

1. Iw Check if new IP address is empty Apply changes e Disconnect the power jack connect the jumper near the RJ11 sockets power up the device and wait 15 seconds Then disconnect the power and disconnect the jumper The device is ready in its factory default configuration Page 5 www HW group com HW group HWg STE plus manual WF Conley 220 0 for AY grup products wvewdim griupotunm 3 WWW interface of the device e To open the WWW interface of the device o Enter the IP address into a web browser Harare S mena eH arom Config uty fo the HW group devices o Click the IP address in UDP Config Show detail settings of device o Click the underlined IP address in UDP Ili m 2 z SETUP pen ECUP LCAIMEC on por Load default values e The WWW page displays current states of inputs and outputs IP address DHCP Outgoing e mail Sensors settings Device IP address setup parameters General Mozilla Firefox Soubor Upravy fobrazeni Historie Z lo ky Nastroje Nap veda G General 192 168 33 20 HWg STE Plus SNMP Email Time Inputs Sensors Portal System Home Graph General Setu General Base Information HWg STE Plus 12 29 48 Dat 22 07 2013 Sensors State Name Type Current value En Qu Sensor 6313 Humidity 30 6 RH j NORMAL mpn puto Comet 1 Gosed V NoRMAL Input2 Input Dry Cont
2. mobile application 0 405 A 0 441 A 2 594 A 4448 557 kWh Energy 23820 9 kWh 4136442 Wh 0 Reload Sensors Page HLVoroup Page 20 www HW group com Contact details HW group s r o Rumunska 26 122 Praha 2 120 00 Tel 420 222 511 918 Fax 420 222 513 833 http www HW group com
3. 59 01 FF B 00 04 59 03 11 9B 00 04 59 01 D6 42 00 04 59 01 DF 2F 00 04 59 00 CF 3C 00 04 59 03 1B 28 00 04 59 00 CF 26 00 04 59 00 D0 11 00 04 59 00 D0 35 00 04 59 00 D0 66 D0 04 53 00 D1 23 DO 04 59 00 CF C3 D0 04 53 00 D0 4C 00 04 59 00 D0 4D 00 04 59 00 D0 81 00 04 59 00 D1 70 00 04 59 00 D2 C5 00 04 59 01 E7 C3 00 04 59 00 D4 29 00 04 59 00 D1 E6 00 04 59 00 D 2 45 00 04 59 01 F6 FC 00 04 59 01 F8 1F 00 04 59 00 D2 4B MAC Name NNI D7 SH4 Cabinet 001 HWwg STE Push Hiwg STE Push Poseidon 3268 Damocles 1208 Poseidon 3266 Poseidon 3266 Poseidon 3266 Poseidon 3266 Poseidon 3266 Poseidon 3266 Poseidon 3266 HWg STE Push SH3 Hwg STE Hadice HWgSTE Pip Device type Pot Parameters 192 168 1 52 IP Watchdog industrial 99 TCP setup Y DHCP Y 192 168 1 69 SH4 TCP setup N DHCP N 192 168 1 72 Poseidon 4001 81 TCP setupzY DHCP N 192 168 1 90 HWwg STE Push 80 TCP setup Y DHCP Y 192 168 1 93 HWwg STE Push 80 TCP setup Y DHCP N 1921681100 Poseidon model 3266 80 TCP setup Y DHCP N 1921681165 Damocles model 1208 80 TCP setup Y DHCP Y 1921681217 Poseidon model 3266 80 TCP setup Y 192 168 1 218 Poseidon model 3266 80 TCP setup Y 192 168 1 219 Poseidon model 3266 80 TCP setup Y 192 168 1 220 Poseidon model 3266 80 TCP setup Y 192 168 1 221 Poseidon model 3266 80 TCP setup Y 192 168 1 222 Poseidon model 3266 80 TCP setupzY 192 168 1 223 Poseidon model 3266 80 TCP setup Y 192 168 1 225 Po
4. 0 amp ZonE true A y m C g Google Portal rea em http sensdesk com portal php Portal Enable Disable Time in Sec 0 Disable Time in Sec 0 Disable IP Address or DNS Name p HWg STE Push f HW group Sensor s autopush config ID name Current vale 6313 Sensor 6313 40 7 RH 7313 Sensor 7313 23 3 9C Save Manual Push HWg STE Push For more information try www hw group com Autopush Delta 4 This will get you to a Portaltab and at the same time the portal function will be activated By clicking the link SensDesk com register your IP sensor a login window on www Sensdesk com will be show a HWg STE Push 5ancDesk Manila Firetex iiber ES Subai pige Eebrapeni Hite Zdo ty H sroje M paynda Tac HS STE Push Sensfesk E L Gi radek com ceni B A E 8 BSerpek a HWg STE Push Address 193 158 2 4 Lserminen Popis Paar Ip habe Sensor Hime Heslnaka Unit Acting ity ETS o Senses 6313 AD 2 RH lm 100 579 o Eensor 7313 25 3 Lm Isec aga Sensors with unit 58H AZ te Senspesk a sud Username Password Kegeiber to Portal iy reset password or Lapin 2 1 tensor wih uni C Page 17 B Sensor 7313 www HW group com HWg STE plus manual HW group 5 In case you already have a user account please enter your login details and the device will be automatically assigned to your account In case you do not have a SensDesk acco
5. 53 00 AC 48 00 04 53 00 AC 43 00 04 59 00 48 FB 00 04 59 03 0E AF 80 250 21 87 Unspecified device Unspecified device Unspecified device Damocles model MINI TCP setup Y TEA N NYT Y TCP setup Y TEA N NYT Y TCP setup Y TEA N NYT Y TCP setup N TCP setup Y TCP setup Y TCP setup Y Poseidon model 1250 Poseidon model 1250 Damocles model 2404 80 250 21 84 192 168 1 148 80 250 21 86 00 04 59 03 0C 2C 00 04 59 03 10 04 00 04 59 03 0C 4B Jan test 485 e To search for devices click the Find Devices icon The program looks for devices on your local network Double click a MAC address to open a basic device configuration dialog Searching modules done Configure network parameters e P address HTTP port 80 by default e Network mask IP address 80 250 21 85 80 MAL 00 D 55 03 OD D Fw version 3 0 2 Device type Poseidon model 3255 DHCP Nat supported Be Open in V EB Browser M ask 255 255 255 240 Gateway 80 250 21 1 Enable IP access filter e Gateway IP address for your network e Device name optional Click the Apply Changes button to save the settings iw Enable TCP setup Open 0 0 0 0 m Restoring factory defaults e Right click on the device MAC address and select Load default values Within 60 seconds after powering up the unit factory defaults can be restored using UDP Config Default values
6. HLVoroup HWg STE plus HWg STE plus PoE MANUAL HWg STE plus manual HW group Page 2 www HW group com HWg STE plus manual HW group HWg STE plus connectors ETHERNET 100 Mbps SENSORS S1 and S2 ports for connecting temperature or humidity sensors PoE power only for HWg STE PoE Max distance 60m for both sensors in total POWER input LED indicators 5V DC power supply Green Power amp Mode Use the supplied power Yellow Link amp Activity adapter Digital Inputs 2x Digital input with LED signalization for connecting dry contact door contacts or relay outputs Setting the device to its factory default 1 Turn the device off unplug the power adapter 2 Open the unit and set the marked jumper 3 Turn on the device for 30 seconds only to set the device back to defaults 4 Turn off the device 5 Remove the jumper set in step 2 Ethernet Power 6 Turn on the device Factory defaults settings is restored enw EEE RJ11 RJ11 Sensors Page 3 www HW group com HWg STE plus manual HW group Recommended connection options Ethernet SensDesk com Online portal Sensors connection options HWg STE plus HWg STE plus HWg STE plus ss sso pie the e Combined Temperature amp Humidity sensor Humidity probe 2x Temperature Sensor in daisy chain Smoke sensor connection HWg STE plus ae Power
7. act open Y Portal Message You can see this page even in Mobile version HWg STE Plus For more infgrmation try www hw group com Sensors overview User defined text for service purposes Current sensor reading Page 6 www HW group com HWg STE plus manual HW group Device configuration H Wg 6 TE Plus Device name Identifies the device in e mails and SNMP Home Graph General Setup SNMP Email Time Inputs Sensors General Setup __ A Description User defined HWg STE Plus 0 to 16 characters footer For HWg STE Plus For more information try a href http www hw group com gt www hw group com lt a gt example administrator s contact details WWW Info Text Temperature unit Celsius Celsius Fahrenheit Ke Periodic restart a Temperature unit for display and alarm inputs Automatic refresh period of web page Sae Network Name Vaue Description Password for configuration 0890 Security Device Admin wmm 7 device configuration changes HWg STE Plus For more information try www hw group com P Admin username password for The configuration password is required for every page except the main page Without entering the password it is then possible to read the current connected sensors values Page 7 www HW group com HWg STE pl
8. adaptor 12V ft Original Power adaptor 5V Page 4 www HW group com HWg STE plus manual HW group 1 Connecting the cables e Connect the unit to the Ethernet patch cable to a switch or a cross over cable to a PC e Plug the power adapter in to a power outlet and connect it to the HWg STE plus power connector e The green Power amp Mode LED in the RJ45 connector lights up e Ifthe Ethernet connection works properly the LINK yellow LED lights up after a short while and then flashes whenever data transfer takes place activity indication e After power up the LINK LED flashes rapidly to indicate IP address negotiation over DHCP 2 Configuring the IP address UDP Config UDP Setup 2 2 0 for HW group products www hw group com A UDP Config utility root directory of the supplied CD Windows and Linux versions Available for download at www HW Your PC network settings 192 168 1 214 255 255 255 0 192 168 1 253 Hw group www hw group com Version H Ir 221 www HW group com IP address Netmask Find Devices Setup utility for the H group devices Gateway group com Device list ooftware UDP Config M M TCP setup Y TCP setup Y TEA N NYT Y TCP setup Y TEAZN NVTzY Poseidon model 3265 Unspecified device 80 250 21 85 192 168 1 61 Unspecified device e Click the icon to launch UDP Config The program automatically looks for connected devices 00 04
9. e measured values Mouse over to show the time and value at the point Safe range threshold set for the sensor The next reload in 898 seconds HWg STE Plus For more information try www hw group com Page 12 www HW group com HWg STE plus manual HW group System HWg STE Plus SNMP Email Time Inputs Sensors Portal System SNMP MIB Text list of most frequent SNMP variables System En Ps Backup configuration HWg STE Config bin N Online values in XML EN SNMP MIB Table HWg STE mib HWg STE OID txt 2 min Demo Mode Enable Proch zet Upload Soubor nevybr n Firmware or Configuration Factory Default System Restart Default Page 13 www HW group com HWg STE plus manual HW group Technical specifications ETHERNET Interface Supported protocols SNMP RJ45 10 100BASE T IP ARP TCP IP HTTP SNTP SMTP HWg Push UDP IP SNMP Version fully supported partially Version2 m X m JJ lt gt m O m U O JJ o Port connector 1 S2 RJ11 1 Wire Two external temperature or humidity sensors One combined temperature and humidity sensor Only HW group s r o sensors Max 2 sensors Max 60m in total for both sensors Can connect Sensor types sensors range DIGITAL INPUTS Dry Contact Inputs Digital Input supports NO NC Dry contact 1 On 0 500 Q R
10. ight pin on the terminal block can be connected to 12V GND woo Power Supply PoE Power over Ethernet RJ45 IEEE 802 3af only with HWg STE plus PoE version LED POWER status Green power OK status DHCP Local alarm LINK amp Activity Yellow Ethernet connectivity JUMPER ITI Load defaults Power on with jumper ON for 30 seconds switch off and remove jumper Other parameters Operating temperature 10 to 60 C operating temperature range does not have to correspond with sensors range Dimensions Weight 65 x 80 x 30 mm 500 g EMC CE FCC Part 15 Class B EN 55022 EN 55024 EN 61000 L lt Q O c D Q 3 Page 14 HWg STE plus manual Mechanical dimensions HW group 79 0 71 0 63 0 c En c tt E Page 15 www HW group com HWg STE plus manual HW group Connecting HWg STE plus and STE Push to SensDesk portal 1 Connect the device to your network and set the network parameters First Steps chapter in the user manual UDP Config 4 13 0 for HW group products www hw group com H A rrr 413 0 www HW group com Version Config utility for the HW group devices Your PC network settings IP address 192 168 1 200 Netmask 255 255 252 0 Gateway 192168 1 254 HW group www hw group com Device list 00 04 5 D 00 04
11. igital Input ID Cn Alarm settings active disabled HWg STE Plus For ma LogO Log1 state names Inputs For example fuel tank Full Empty or front door Open Closed Sends an email in case of alarm if ticked Page 9 www HW group com HWg STE plus manual HW group Sensors HWg STE Plus Home Graph General Setup SNMP Email Time Inputs Sensors Portal Inactivity period before and after each alarm Sensors Sensor list urrent Sensor qe ee 2 Ed Sensor 633 30 6 RH 30 0 ra 80 0 10 0 26a91800590a00fb EI Find Sensors 7 zs WV more information try www hw group com Safe Range device sends xx an email when this Deletes the sensor from the list threshold is exceeded 10 0 60 0 Find Sensors Scans for changes in connected sensors Note After connecting a new sensor or exchanging an existing one always click Find Sensors Hysteresis Hysteresis prevents receiving tens and hundreds of alarm messages about start and ending of alarm while the value oscillates around the Safe Range threshold Set the value in C or RH mostly using 1 to 4 C or approximately 5 RH is enough You can find more on HWg websites in AN35 Poseidon Preventing false alarms og Fd aot FX SEN a of fs P E 7 r F r ke Pg gu s EM s a ri i B S eu Alarm state Time Page 10 ww
12. ntifies the device in communication with your account and in communication of mobile applications with SensDesk The password cannot be changed and for a security reason it is different to the login password tater Upp t Meret emsDesh E radsi com C Desk Castoomd Desce CL TL Derce yox attempt Mester to Page 19 www HW group com HWg STE plus manual HW group PUSH Device Password can be used in devices to skip the logging procedure during assigning a device to your portal account without going through the logging process Portal Mozilla Firefox a amp eubnr Uprey Zekrareni Historie Falpsiy Marge Mipoy ds fe attempt SensDesk af Penal d S d tiiki yu partaba By ayr DOS tf HWg STE Push E Home Graph General Setup SNMP Email Time Sensors Portal System Portal Portal Message Portal config Mame Value l m A Portal Enable Disable Push Period a id Tmein5ec 0 Disable Cea nj TT UN hitn sensdesk oompertal php BW eaAddress or DNS Kame RTE TT Usemame 7 nom TN ETE NER NETT NEP INR MELLE NN Sensor s autopush config m Mame CurrentValue Feu eeu ET i m mua seen max X20 7 HWg STE Push For mone mformaton Try yarenler oup paT Using the mobile phone Application HWg Sensors Username and PUSH Device Password can be used also for setting the
13. seidon model 3266 80 TCP setup Y 192 168 1 227 Poseidon model 3266 80 TCP setup Y 192 168 1 228 Poseidon model 3266 80 TCP setup Y 192 168 1 230 Poseidon model 3266 80 TCP setup Y HW9STE Push 80 TCP setup Y DHCP Y 192 168 2 15 SH3 80 TCP setup N DHCP Y 1921682110 Poseidon model 3266 80 TCP setup Y 1921682111 Poseidon model 3266 80 TCP setupzY 1921682113 Poseidon model 3266 80 TCP setup Y 1921682153 HWgSTE Hadice 80 TCP setup N DHCP Y 192 168 3 58 Hwg STE 80 TCP setup N DHCP Y 4 About Find Devices Searching modules done 2 Then open the WWW setup of the device Page 16 General Mozilla Firefox Soubor Upravy Zobrazen Historie Z lo ky N stroje N pov da d General Si 192 16824 Le g m n C J Google HWg STE Push Home Graph General Setup SNMP Email Time Sensors Portal System General Base Information HWg STE Push 09 38 36 23 08 2013 Portal Message You can see this page even in Mobile version HWg STE Push For more information try www hw group com www HW group com HWg STE plus manual 3 On the Home tab click the Activate button in Portal Message section cma Soubor pravy Zobrazen Historie Z lo ky N stroje N pov da P Portal ES Portal Message Portal config Log Period Server Address Portal Mozilla Firefox St 192 168 2 4 cgi bin sys portal asp Portal Activate amp ZonT 1
14. unt yet click the Register to Portal link and a registration form will be shown Seebor Use c Martes Page dia Se Uteh et Sere E lt e srode cor H P 4 co 6 Enter the login details for your new account and a correct e mail address E mail address has to be unique for the server cannot be already registered under another account Company name field allows you to create your own 3rd level domain usually company sensdesk com A user name will be used if the Company name field is left empty After clicking Create new account button a user account will be created and at the same time a confirmation email is sent to the entered e mail address This e mail contains a confirmation link which has to be used in order to activate the account Page 18 www HW group com HWg STE plus manual HW group 7 By activating the account you will be redirected to the Invitation page At this moment the data sending period is set to 10 seconds to show the sensors functionality This page is active only for approximately 15 minutes after the activation then the logging period changes to 15 minutes puba puany Dope plies Tuigiiy pure Ny Ge bre STE Bach Soros r Tr Ets oes za e Lopa Hiara Messages LES eur IP sensors portal Daath Sensors pere paard Ceres HWg STE Push In your user account configuration My Account link you can find your Push Device Password This password together with your login name ide
15. us manual HW group SNMP LOT LE Plus Port for SNMP polling Graph General Setup SNMP Email Time Inputs Sensors Portal System SNMP SNMP device identification same as the device name eM STE Oto 16 EET ee VL HUig STE Plus For more information try http www hw group com General SNMP C System Contact Download MIB file Show OID keys table HWg STE Plus For more information try www hw group com Email HW q STE Plus SMTP server to use for sending e mails Graph General Setup SNMP Email Time Inputs Sensors Portal System Email Email Settings an SS Se 7 Authentication Enable Disable ss em rn FROM user domain com com Subject Beginning of email subject es com Send Test Email Device email address Sends a test e mail to all entered recipients HWg STE Plus For more information try www hw group com Page 8 www HW group com HWg STE plus manual HW group Time HWg STE Plus SNMP Email Time Inputs Sensors Portal System Home Graph General Setu Time SNTP Setup Name Vawe Description 1 Number 12 13 Summertime HM last Sun Mar 2 00 last Sun Oct 2 00 Sae Digital Inputs SNMP Email Time Inputs 54 Input Dry Contact N D
16. w HW group com HWg STE plus manual Portal HWg STE Plus Home Graph General Setup SNMP Email Time Inputs Sensors Portal System Portal communication Po rtal Message a Portal oun Description Portal Enable Disable Time in Sec 0 Disable Target portal settings with login details Time in Sec 0 Disable hti IF Address or DNS Name RE EE wem RC a Portal username and passwort sant autopush config eS eee mput2 Open T Enable Disable Sensor s autopush config e oo MEL TE AutoPush function and sensitivity settings delta value change HWg STE Plus For more information try www hw group con Portal function periodically sends data to a remote server Sending period depends on the time set on a server that operates the portal AutoPush is a function allowing sending of measured data in case of value increase decrease larger than AutoPush delta parameter Page 11 www HW group com HWg STE plus manual HW group Graph HWg STE Plus Home Graph General Setup SNMP Email Time Inputs Sensors Portal System Choose a sensor to show its graph Values are stored on RAM memory Nb Setup ame Seno 13 7 900 SER Time in Second 0 Disabled Name Sensor 6313 Type Humidity Descriptio Graph actualization period s Graph of th

Download Pdf Manuals

image

Related Search

Related Contents

AED Pro Op Guide (0350-02 Rev D).book  Arecont Vision MegaBall™ Installation Manual - Surveillance  HARVIA 20 GF  P 227 - PH 227  Platinum Retroviral Expression System, Pantropic  Topcon GTS-823A User's Manual  N-Tron 105TX Ethernet Switch Manual  GE 14 Refrigerator User Manual  IPEMB2FI & IPEMT2FI User Manual  Anleitung DTA 25-2_SPK2  