USER`S MANUAL “IRIS” TILT SWITCH AND

image

Contents

1. A Powerful Control Device The firmware on the standard IRIS board has 5 user programmable thresholds When a tilt measurement is taken it is compared to each of these thresholds X tilt X tilt Y tilt Y tilt and tilt in any direction If the measurement exceeds one or more of the thresholds the corresponding output pin s in the H3 connector are set high SV as shown below If the threshold is not exceeded the output remains at 0 Volts The reference angle for the threshold measurement is selected using the autozero command Threshold checking may be turned off with a single firmware command when it is not needed The standard IRIS firmware also allows the user to set the hysteresis of the control thresholds The hysteresis is used as follows After an H3 output pin is set high it APPLIED GEOMECHANICS INCORPORATED is not set low again until the tilt reading has reached a level that is below the threshold by an amount equal to the hysteresis see diagram IRIS includes 3 additional control output pins in the H3 connector bringing the total to 8 The 3 additional pins are not active in the regular versions of the product but may be implemented for your application by custom programming by our engineers Each of the 8 control outputs is separately programmable Another custom option is normally high control output instead of the standard normally low output With normally high controls the voltage
2. A TeU A i TaU A B TUU A Tz The BAE output string is not clearly decipherable by HyperTerminal which sometimes hides characters that it has received and cannot understand Because of this it is difficult if not impossible to interpret data in this format The above output string shows four outputs taken from HyperTerminal This encoded output command is typically used to communicate with embedded systems as they can view raw data and perform fast translations The first synchronization byte is 0x55 the second is OxAA The X and Y bytes use 0 0000277 angular degrees per LSB hence the total output range of this output mode is limited to the model D711 2A 4X The temperature uses 0 004 degrees Celsius per LSB The serial number is a two byte integer The checksum byte is the result of ANDing bytes 2 7 with 255 APPLIED APPLIED N B 06 1001 Rev A 5 oe IRIS Tilt Switch and Controller BAE output mode reduces the total number of characters per output to 11 bytes while transferring the same data as the SIM output mode which requires 33 bytes BAE mode also includes checksum and frame synchronization bytes Refer to Appendix A Firmware Commands to decode the output 4 Firmware Commands Valid commands are listed below Some commands have more than one string to trigger the command tt stands for the target ID 99 and ss stands for the source ID 00 Settings stored in nonvolatile memory remain in effect unt
3. SPASHS XDR A x x D N A x xX D E C x x C T sn lt CR gt lt LF gt I Serial number Comment T for temperature Units C degrees C Temperature of tiltmeter Data Type C Temperatur Comment E for East West direction Units M microradians D degrees XxX E tilt value Data Type A Angular Comment N for North South direction Units M microradians D degrees Y N tilt value Data Type A Angular Example SPASH XDR A 00 920 D N A 00 210 D E C 030 045 C T N1212 TCM SPy y Rx x hh lt CR gt lt LF gt l l l l CheckSum Roll X tilt value in degrees Pitch Y tilt value in degrees Example SP 00 905R002 190 19 BAE abcdefghijk LILI Byte 10 k Checksum of bytes 2 7 ANDed with decimal 255 LILI Byte 8 9 i j3 Serial number in hexadecimal format Byte 6 7 g h Temperature in Deg C Bits 14 0 magnitude LSB bit 0 004 Deg C Bit 15 sign Byte 4 5 e f Y Axis Level Data Bits 14 0 magnitude LSB bit 0 0000277 degrees Bit 15 sign Byte 2 3 c d X Axis Level Data Bits 14 0 magnitude LSB bit 0 0000277 degrees Bit 15 sign Byte 1 b OxAA 2 Synchronization Byte Byte O a 0x55 1 Synchronization Byte Syntax ttssSO lt output format gt lt CR gt lt LF gt Error Strings ERR XY SO BAD PARAMETER lt output format gt was invalid ERR XY SO PARSE ERROR Could not parse lt output for
4. lt none gt XY SET CTRLTEST ON Sets the control pin high 5 VDC regardless of whether B 06 1001 Rev A control feature is on or off Convenient for testing control functionality regardless of tilt Syntax ttssxXY SET CTRLTEST ON lt CR gt lt LF gt Error Strings None Default Off Persistence Control pin stays high until the user issues the command XY SET CTRLTEST OFF or disconnects power Example command 9900XY SET CTRLTEST ON lt CR gt lt LF gt response lt none gt APPLIED 14 GEOMECHANICS INCORPORATED IRIS Tilt Switch and Controller XY SET CTRLTEST OFE Sets the control pin low 0 VDC If the control feature is on and the tilt falls above the positive threshold value minus the hysteresis value or falls below the negative threshold value plus the hysteresis value the control pin may go high again immediately XY SET CTRL OFF turns off the control feature altogether Syntax ttssxXY SET CTRLTEST OFF lt CR gt lt LF gt Error Strings None Default Off Persistence None If the control feature is on and the tilt exceeds the hysteresis value the control pin may go high again immediately Example command 9900XY SET CTRLTEST OFF lt CR gt lt LF gt response lt none gt XY SET THRESHOLD x x yt y Sets the control thresholds The parameter x is the positive threshold for the x axis
5. 13 Firmware Version 5 10 Rev D X Ch Gain 1 0000 Y Ch Gain 1 0000 Temperature Gain 1 0000 Output Mode Degrees Using RS232 Real Time Clock Not Installed External Flash Capacity 0 Bytes Not Installed Relay Thresholds Xpositive 1 0000 Xnegative 1 0000 Ypositive 1 0000 Ynegative 1 0000 Calibration method Dynamic Positive Limit 1 5000 Negative Limit 1 5000 Calibration Points 041 X Disabled Y Enabled Uniaxial x2 Sensor Type 2 ADC Channels Two B 06 1001 Rev A 17 APPLIED GEOMECHANICS INCORPORATED 5 WARRANTY and LIMITATION of LIABILITY Standard goods those listed in Applied Geomechanics published sales literature excluding software manufactured by Applied Geomechanics Inc AGI are warranted against defects in materials and workmanship for twelve 12 months from the date of shipment from AGI s premises with the following exceptions Series 900 analog or digital clinometers are warranted against defects in materials and workmanship for 90 days from the delivery date AGI will repair or replace at its option goods that prove to be defective during the warranty period provided that they are returned prepaid to AGI and a that the goods were used at all times for the purpose for which they were designed and in accordance with any instructions given by AGI in respect of them b that notice is received by AGI within 30 days of the defects becoming apparent and c that return
6. 699 000 071 020 330 N0000 S 00 699 000 071 020 348 N0000 S 00 700 000 070 020 360 N0000 XYC OFF Turns off XYC mode Syntax ttssxXYC OFF lt CR gt lt LF gt Error Strings None Default N A Persistence Setting is stored in nonvolatile memory Example command OQ100XYC OFF lt CR gt lt LF gt response 0100XYC OFF lt CR gt lt LF gt APPLIED B 06 1001 Rev A 13 oe IRIS Tilt Switch and Controller XY SET CTRL ON Enables control feature If the tilt exceeds either threshold in any direction the control pin will go high 5 VDC until the tilt falls below the positive threshold value minus the hysteresis value or falls above the negative threshold value plus the hysteresis value Syntax ttssxY SET CTRL ON lt CR gt lt LF gt Error Strings None Default On Persistence Setting is stored in nonvolatile memory Example command 9900XY SET CTRL ON lt CR gt lt LF gt response lt none gt XY SET CTRL OFF Disables control feature The control pin will remain at ground potential 0 VDC unless the user issues the command XY SET CTRLTEST ON or turns the control feature on again by issuing the command XY SET CTRL ON Syntax ttssxXY SET CTRL OFF lt CR gt lt LF gt Error Strings None Default On Persistence Setting is stored in nonvolatile memory Example command 9900XY SET CTRL OFF lt CR gt lt LF gt response
7. PASH ON Translates the Paros provided PASHS XDRP sentences to standard NMEA XDR format XY TR PASH OFF Turns off translation of PASHS XDR P sentences APPLIED SSS B 06 1001 Rev A 2 aoe IRIS Tilt Switch and Controller XY EP XY SP XY EE XY SE XY SET BAUDRATE x XY SET N SAMP x XY SET RSMODE x XY AUTOZ XY AUTOZOFF XYCx x 0 yal x 2 x 3 x 4 x 5 x 6 x 7 x OA x 1A x 2Aorx A XYC OFF XY SET CTRL ON XY SET CTRL OFF XY SET CTRLTEST ON XY SET CTRLTEST OFF B 06 1001 Rev A Enables power on message Disables power on message Enables echoing of global 99 commands Disables echoing of global 99 commands Sets baud rate to value of x in bits per second Selectable values include 9600 19200 28800 57600 115200 and 230400 baud Sets number of samples that are averaged before a reading is transmitted x may have any value from 1 to 1000 Changing this value may also change the output rate Selects serial output mode x 0 RS232 x 1 RS485 RS422 Turns on auto zero function Turns off auto zero function Continuously sends XY data where x determines output rate as follows 8 10 outputs per second 4 outputs per second 1 output per second default 1 output every 10 seconds 1 output every 60 seconds 1 output every hour 1 output every 12 hours 1 output every 24 hours Averaging of the 8 10 outputs per second data Averaging of the 4 outputs per second data Averaging of the 1 out
8. PASHS XDR A 004 261 D N A 004 280 D E C 021 288 C T N1346 PASHS XDR A 004 261 D N A 004 280 D E C 021 306 C T N1346 PASHS XDR A 004 261 D N A 004 280 D E C 021 298 C T N1346 PASHS XDR A 004 261 D N A 004 280 D E C 021 332 C T N1346 SO SIM default Simple X Y T SN output which returns the X and Y tilt angle in degrees and the internal temperature of the MD 900 T in C 00 619 000 023 018 910 NO000 00 619 000 023 018 923 NO000 00 620 000 024 018 932 NO000 00 620 000 023 018 951 NO000 SO XDR Standard NMEA XDR output string which returns the North South Y and East West X tilt angle in degrees and the internal temperature of the MD 900 T in C YXXDR A 000 034 D N A 00 625 D E C 021 651 C T N0000 47 YXXDR A 000 034 D N A 00 624 D E C 021 675 C T NO000 40 YXXDR A 000 034 D N A 00 624 D E C 021 686 C T NO000 4C YXXDR A 000 034 D N A 00 625 D E C 021 707 C T NO000 45 SO TCM Proprietary Trimble Navigation pitch Y tilt and roll X tilt output string which returns the tilt angle in degrees and a checksum P 00 907R002 186 1C P 00 906R002 183 18 P 00 908R002 191 15 P 00 908R002 191 15 P 00 905R002 190 19 SO BAE Advanced users only using the D711 2A 4X BAE Systems encoded 11 byte output which returns two synchronization bytes the X 2 bytes and Y 2 bytes tilt angle the internal temperature of the tiltmeter 2 bytes the serial number 2 bytes and a checksum byte U
9. authorization is received from AGI prior to the goods being sent back Should goods be damaged in transit to the Purchaser AGI will accept no liability unless the Purchaser can show that such damage arose solely from AGI s failure to pack the goods properly for shipment Software products are warranted to perform substantially in accordance with their documentation for 90 days following your receipt of the software AGI and its suppliers do not and cannot warrant the performance or results you may obtain by using the software or its documentation In respect of goods or parts thereof manufactured by others and resold by AGI AGI will pass on to the customer the benefit of any guarantee or warranty received by AGI from the original manufacturer insofar as such guarantee or warranty is assignable ANY OTHER CONDITIONS OR WARRANTIES WHETHER EXPRESS OR IMPLIED BY STATUTE OR OTHERWISE ARE EXCLUDED THE REMEDIES PROVIDED HEREIN ARE THE BUYER S SOLE AND EXCLUSIVE REMEDIES APPLIED GEOMECHANICS INC SHALL NOT BE LIABLE FOR ANY DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING LOST PROFITS OR LOST SAVINGS WHETHER BASED ON CONTRACT TORT OR ANY OTHER LEGAL THEORY THIS WARRANTY EXTENDS ONLY TO THE ORIGINAL PURCHASER AND IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES WHETHER OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR USE AND OF ALL OTHER OBLIGATIONS AND LIABILITIES OF ANY KIND AND CHARACTER THERE ARE NO WARRANTIES WHICH EX
10. in the current output units default is degrees and so on for parameters x y and y If the tilt xceeds either threshold on either axis and the control feature is on the control pin goes high 5 VDC until the tilt falls below the positive threshold value minus the hysteresis value or falls above the negative threshold value plus the hysteresis value Syntax ttssxY SET THRESHOLD x x y y lt CR gt lt LF gt Error Strings ERR XY SET THRESHOLD PARSE ERROR Default xt 1 x 1 ye Set y St Persistence Setting is stored in nonvolatile memory Example command 9900XY SET THRESHOLD 5 3 244 4 0 0 lt CR gt lt LF gt response lt none gt APPLIED B 06 1001 Rev A 15 ee IRIS Tilt Switch and Controller XY S ET HYST x Sets the control hysteresis hysteresis value in the current output units where the parameter x is the default is degrees If the tilt exceeds either threshold on either axis and the control feature is on the control pin remains high 5 VDC until the tilt falls below the positive threshold value minus the hysteresis value or falls above the negative threshold value plus the hysteresis value Syntax ttssxY SET HYST x lt CR gt lt LF gt Error Strings ERR XY SET HYST PARSE ERROR Default 0 Persistenc Setting is stored in
11. nonvolatile memory Example command 9900XY SET HYST 0 5 lt CR gt lt LF gt response lt none gt XY DUMP SETTINGS Dumps settings of device Syntax ttssXY DUMP SETTINGS lt CR gt lt LF gt Error Strings None Default N A Persistence N A Example command 9900XY DUMP SETTINGS response APPLIED GEOMECHANICS Tiltmeter Firmware V5 0 SN N2144 IDO1 01 Vbias 2047 000000000 2047 000000000 NaN NaN 01 Vgain 0 005000000 0 005000000 0 000610350 0 000610350 Ol Vmin 2 50 2 50 2290 2 50 01l Vmax 2 50 2 50 2 50 2 50 01 ad 0 00000 0 00000 0 00000 0 00000 0 00000 0 00000 0l al 0 00000 0 00000 0 00000 0 00000 0 00000 0 00000 Ol a2 0 00000 0 00000 0 00000 0 00000 0 00000 0 00000 01 a3 0 00000 0 00000 0 00000 0 00000 0 00000 0 00000 01 Tcoef 0 Ks 0 0003 Kz 0 Tcal 25 01 Tcoef 1 Ks 0 0003 Kz 0 Tcal 25 01 N_SAMP 1000 Xzero 0 00 Yzero 0 00 01 TR PASH OFF E99 ON SO NMEA SIM XY EP 9600 baud FV APPLIED GEOMECHANICS B 06 1001 Rev A 16 INCORPORATED IRIS Tilt Switch and Controller XY DUMP 2 Dumps extended settings of device OL Above 0 00 KZMinTemp kz 0 Below 0 00 KZMinTemp kz 2 oo holokolololononolololonone PRPPPREPRPRPRPEPPHPEPE H Syntax ttssXY DUMP2 lt CR gt lt LF gt Error Strings None Default N A Persistence N A Example command 9900XY DUMP2 response TBias 8 95 oll oo SN nw N N wr oll oo Sg oo mee re ADCDelay 310 PCA Model 84833
12. positive number Set x y a positive or a negative number When tilt gt x pin H3 8 goes high When tilt lt x and x gt 0 pin H3 8 goes high When x lt 0 only the positive threshold is used for the General Alarm Hysteresis Figure 6 is applied to all thresholds in the same manner Set the hysteresis using the XY SET HYST k command Caution Always verify that your control thresholds are functioning as intended before using your IRIS Tilt Switch amp Controller in critical applications Applied Geomechanics Inc shall not be liable for any direct indirect special incidental or consequential damages 3 Sample Data Using the XY Command When you use your IRIS circuit to collect tilt data the most commonly used command is the XY command which returns the X and Y tilt angles in degrees and the internal temperature of the MD900 T in C The format of the returned data depends on the setting of the SO command The returned data are averages of a series of readings The number of samples used in the average is set by the XY SET N SAMP command The following lines illustrate the format of the data returned by the XY command for the range of possible SO settings SO ASH Ashtech compatible NMEA output string which returns the North South Y and East West X tilt angle in degrees and the internal temperature of the MD 900 T in C APPLIED B 06 1001 Rev A 4 oe IRIS Tilt Switch and Controller
13. TEND BEYOND THE DESCRIPTION ON THE FACE HEREOF AGI s liability arising out of the sale of its goods is expressly limited to the repair and or replacement of defective parts or the cost of such repair and or replacement If software does not perform substantially in accordance with the documentation the entire and exclusive liability and remedy shall be limited to either at AGI s option the replacement of the software or the refund of the license fee you paid for the software Liability for any other form of loss or damage is hereby expressly excluded Customer shall indemnify AGI against any third party claim arising out of the use of goods and or services supplied by AGI including any claim arising directly or indirectly out of alleged negligence on the part of AGI its employees servants representatives or agents B 06 1001 Rev A 18 APPLIED GEOMECHANICS
14. USER S MANUAL IRIS TILT SWITCH AND CONTROLLER Serial No High Gain Version 10 degrees Standard Version 25 degrees Wide Angle Version 50 degrees APPLIED SS GEOMECHANICS INCORPORATED 1336 Brommer Street Santa Cruz CA 95062 USA Tel 831 462 2801 Fax 831 462 4418 applied geomechanics com www geomechanics com Copyright 2006 by Applied Geomechanics Inc All rights reserved Document No B 06 1001 Rev A APPLIED WN IRIS GEOMECHANICS Tilt Switch and Controller The IRIS Tilt Switch and Controller is a powerful control device that enables you to measure and respond to rotational movements in any direction with reference to the unchanging gravity vector Use IRIS to maintain platform levelness avoid tipover conditions prevent out of range movement and for many other control requirements IRIS detects angular position with an on board electrolytic tilt sensor which has no mechanical moving parts to break or wear out The standard firmware includes five user programmable set points for tilts in different directions When a selected threshold is reached the circuitry sets the output high on one of the pins in the H3 control connector Three additional control outputs are available for firmware upgrades in custom applications IRIS is also a multi featured inclinometer which format can be continuously output to external devices contributes to its powerful
15. control capabilities Data Firmware commands include averaging autozero and sampling rates which are also the threshold checking other powerful functions Call us for details or to place an rates are user selectable and inclination data in order ASCII High Gain Version Standard Version Wide Angle Version ANGULAR RANGE 10 degrees 20 degree span 25 degrees 50 degree span 50 degrees 100 deg span RESOLUTION 0 005 degree 0 012 degree 0 025 degree ACCURACY 1 of full span TIME CONSTANT T 150 msec output is proportional to 1 e where t time in seconds NATURAL FREQUENCY 7 Hz available with viscous sensor to filter vibrations TEMPERATURE COEF Span 0 03 C Zero 10 20 arc sec C typical SAMPLE RATES User selectable from 10 second to 1 hour DATA STORAGE 512 kB of nonvolatile Flash Memory available as an option SERIAL OUTPUT RS232 or RS422 485 full duplex Baud rate 9600 default 19200 28800 57600 115200 230400 DATA FORMATS Formats NMEA XDR Trimble proprietary Ashtech compatible Simple x y temperature serial number 8 TTL compatible CMOS control outputs 0 5 VDC 5 with user programmable set points 3 available for custom CONTROL OUTPUTS applications Each channel can source up to 20 mA not to exceed 100 mA for all 8 channels POWER REQUIREMENTS 7 28 VDC 27 mA 250 mV peak to peak ripple max reverse polarity and surge protected ENVIRONMENTAL 40 to 85 C operating and storage 90 humidity n
16. il disabled even after a power cycle XY Outputs a single tilt measurement depends on the setting of the SO command Syntax ttssxXY lt CR gt lt LF gt Error Strings None Default N A Persistence N A Example command response 9900XY lt CR gt lt LF gt SO are SIM Sx x y y t t sn lt CR gt lt LF gt l l l Serial number l Y tilt value in degrees X tilt value in degrees Example 00 920 00 210 030 045 N1212 XDR YXXDR A x x D N A X x D rxy Gt l l l l e F ma Comment Units M mi X Data Type Comment Units M microradians Y N tilt value Data Type A Angular Example SYXXDR A 00 920 D N A 00 210 D E A Angu B 06 1001 Rev A SYXXDR A 00 920 D N A 00 210 D E Selects the output format for the XY command Temperature of tiltmeter Units Temperature of tiltmeter Data Type p P N for North South The format of the output C 030 045 C T N1212 57 The possible formats sn hh lt CR gt lt LF gt Checksum Serial number Comment T for temperature C degrees C r C Temperatur for East West croradians F X direction D degrees E tilt value lar Y direction D degrees L C 030 045 C T N1212 57 APPLIED GEOMECHANICS INCORPORATED IRIS Tilt Switch and Controller ASH
17. level of the H3 pin is 5V until a threshold is reached at which time it switches to OV A ee VIEL AUK Yj In the regular versions of IRIS the control pins in connector H3 are all set high for approximately 150 milliseconds on power up after which they reset to their normally low value of OV until a tilt threshold is detected Connector Pinout Tables HiPin Function H2Pin Function 1 Power 7 28 VDC 1 Power 7 28 VDC 2 Ground 2 Ground 3 Tx RS 232 3 Ground 4 Rx R S232 4 Reserved 5 TxHRS422 5 Reserved 6 Tx RS 422 6 Reserved 7 Rx R5422 7 Reserved 8 Rx RS422 8 Reserved H3 Pin Function 1 X tilt threshold 2 X tilt threshold 3 Y tilt threshold 4 Y tilt threshold 5 Optional threshold 6 Optional threshold 7 Optional threshold 8 Threshold in any direction 9 Ground 10 3 3 VDC output Custom firmware only 1336 Brommer Street Santa Cruz CA 95062 USA Tel 831 462 2801 Fax 831 462 4418 applied geomechanics com e www geomechanics com B 06 1001 Rev A 2006 Applied Geomechanics Inc IRIS Tilt Switch and Controller APPLIED GEOMECHANICS INCORPORATED Figure 1 RIS dimensions Specifications are subject to change without notice as the result of ongoing development 1336 Brommer Street Santa Cruz CA 95062 USA Tel 831 462 2801 Fax 831 462 4418 applied geomechanics com e www geomechanic
18. lt CR gt lt LF gt Error Strings None Default On Persistence Setting is stored in nonvolatile memory Example command 0100XY response lt none gt T iE lt CR gt lt LF gt APPLIED B 06 1001 Rev A 10 aoe IRIS Tilt Switch and Controller XY SE Disables echoing of global 99 commands If the unit receives a command for ID 99 then the unit will respond but the unit will NOT echo the command when it is done Syntax ttssXY SE lt CR gt lt LF gt Error Strings None Default N A Persistence Setting is stored in nonvolatile memory Example command 0100XY SE lt CR gt lt LF gt response lt none gt XY SET BAUDRATE x Changes communications baud rate Maximum supported baud rate is 57 600 baud The parameter x is an integer with up to six places defining the baud rate as follows 9600 9600 baud 19200 19200 baud 28800 28800 baud 57600 57600 baud 115200 115200 baud 230400 230400 baud Syntax ttssXY SET BAUDRATE x lt CR gt lt LF gt Error Strings ERR XY SET BAUDRATE x PARSE ERROR Default 9600 Persistence Setting is stored in nonvolatile memory Example command 9900XY SET BAUDRATE 57600 lt CR gt lt LF gt response lt none gt XY SET N SAMP x Sets the number of samples that are averaged before a reading is transmitted The parameter x is an integer between 1 and 1000 equal to the
19. lt LF gt If you change the output protocol you will no longer be able to communicate with the tiltmeter unless you have the correct interconnect cable XY AUTOZ Turns autozero function on causing tiltmeter to subtract current X and Y readings from all subsequent X and Y readings Syntax ttssXY AUTOZ lt CR gt lt LF gt Error Strings None Default Off Persistence Setting is stored in nonvolatile memory Example command 9900XY AUTOZ lt CR gt lt LF gt response lt none gt XY AUTOZOFF Turns autozero function off causing tiltmeter to display B 06 1001 Rev A non biased unshifted position readings Syntax ttssXY AUTOZ OFF lt CR gt lt LF gt Error Strings None Default Off Persistence Setting is stored in nonvolatile memory Example command 9900XY AUTOZ OFF lt CR gt lt LF gt response lt none gt APPLIED 12 GEOMECHANICS INCORPORATED IRIS Tilt Switch and Controller XYCX Continuously sends XY data ven after power has been turned off and then on again Timing is determined by the microprocessor s crystal and is approximate The parameter x is an integer between 1 and 7 the letter A or OA 1A or 2A An A indicates the use of the moving average function in which the moving average of the data is output When the moving average function is used the first output is delayed until the first n readings have been taken where n is the number of readings t
20. mat gt Default SIM Persistence Setting is stored in nonvolatile memory Example command 9900SO XDR lt CR gt lt LF gt response lt none gt APPLIED GEOMECHANICS B 06 1001 Rev A 7 INCORPORATED IRIS Tilt Switch and Controller XY MEMS Stores the tiltmeter readings in simple format SO SIM at selected output rate in nonvolatile memory Syntax ttssxXY MEMS lt CR gt lt LF gt Error Strings None Default N A Persistence Subsequent tiltmeter readings stored in nonvolatile memory until memory is full Maximum of approximately 150 lines of data Example command 9900XY MEMS lt CR gt lt LF gt response lt none gt XY MEMD Downloads the tiltmeter readings in nonvolatile memory to PC Syntax ttssxXY MEMD lt CR gt lt LF gt Error Strings None Default N A Persistence Stored tiltmeter readings downloaded at rate of 1 per second to PC in ASCII comma delimited string Example command 9900XY MEMD lt CR gt lt LF gt response Sstart 11 11 1997 18 43 09 4 sec 000 699 01 022 025 116 N1028 000 699 01 022 025 116 N1028 000 698 01 021 025 110 N1028 000 698 01 022 025 122 N1028 XY M1 Sets the operation to Mode 1 This command groups several other commands together for convenience The commands that are issued are XY TR PASH ON XY SO XDR XY S XY SF U FI Syntax ttssxXY M1 lt CR gt lt LF gt Error Stri
21. n Figures 1 6 We have provided a short cable whip pigtail for each of these connectors as part of the normal IRIS product package assembly 98021 XX These whips include two serial cables each terminated with a DB9 connector One is for RS232 communications the other for RS422 485 All serial connections are made through H1 Power for the circuit is supplied using the power and ground pins on H1 or H2 The two grounds on H2 pins 2 and 3 are common on the IRIS printed circuit assembly Pins 4 8 of H2 are reserved for new product features that are not yet implemented Do not connect to or short pins 4 8 of H2 All control functions are provided through the H3 connector Pins 1 4 and 8 of H3 are switched outputs H3 pin 9 ground is common with the ground pins in H1 and H2 For control applications we recommend the use of H3 pin 9 as ground to avoid the possibility of ground loops H3 pins 5 7 are reserved for custom firmware versions When using the standard firmware do not connect to or short pins 5 7 of H3 2 Communicating with the RIS Tilt Switch and Controller The most common way of communicating with the IRIS Tilt Switch and Controller is using a terminal emulator program e g Terminal in Windows 3 1 or HyperTerminal in Windows 95 and later All communication are performed through the send transmit and receive wires of the serial port The default parameters for the serial port are set to no parity 8 bits and 1 stop bit with no hardwa
22. ngs None Default N A Persistence Setting is stored in nonvolatile memory Example command 9900XY M1 lt CR gt lt LF gt response AGI Model D711 2A 4X Firmware V2 2 SN N1212 IDO1 APPLIED B 06 1001 Rev A 8 ee IRIS Tilt Switch and Controller XYVR Displays the sign on string Syntax ttssXYVR lt CR gt lt LF gt Error Strings None Default N A Persistence N A Example command 9900XYVR lt CR gt lt LF gt response AGI Model D711 2A 4X Firmware V5 2 SN N1212 IDO1 ID This command is not currently supported Sets the ID of units in the daisy chain The first device in the serial chain sets its ID to the source ID plus one ss 1 and then outputs a the ID command to the next device with the source ID set to its new ID The target ID of this command must be 99 Syntax 99ssID lt CR gt lt LF gt Error Strings None Default 01 Persistence Setting is stored in nonvolatile memory Example command 9900ID lt CR gt lt LF gt response 9901ID lt CR gt lt LF gt XY TR PASH ON Translates the Paros provided S PASHS XDR P sentences to standard NMEA XDR format An example input PASH string would be SPASHS XDR P 1 000123 B SN123 C 22 12 C SN123 H 32 11 P SN123 lt CR gt lt LF gt The translated string would then be SWIXDR P 1 000123 B SN123 C 22 12 C N123 H 32 11 P SN123 hh lt CR gt lt LF gt Syntax ttssXY TR PASH ON lt CR gt lt LF gt Error String
23. number of samples that are averaged Syntax ttssxXY SET N SAMP x lt CR gt lt LF gt Error Strings None Default Depends on data output rate as specified by the XYCx command The default numbers of samples averaged for each data rate are XYCO 28 XYC1 100 XYC2 460 XYC3 500 XYC4 500 XYC5 500 XYC6 500 XYC7 500 If the number of samples specified exceeds the number listed above for XYCO XYC1 or XYC2 the microprocessor reduces the data output rate until it has enough time to collect and average all of the samples APPLIED B 06 1001 Rev A 11 aoe IRIS Tilt Switch and Controller Persistence Once initiated the same averaging remains in effect even with power cycle Setting is stored in nonvolatile memory Can be changed by reissuing the command with a different value for x or by changing the output rate with the XYCx command Example command 9900XY SET N SAMP 250 lt CR gt lt LF gt response lt none gt XY S CAUTION ET RSMODE x Sets output protocol to RS232 or RS485 RS422 as follows x 0 RS232 x 1 RS485 RS422 CI Syntax ttss XY SET RSMODE x lt CR gt lt LF gt Error Strings None Default Set in factory to customer specification Persistence Once initiated remains in effect even with power cycle Setting is stored in nonvolatile memory Example command 9900XY SET RSMOD response lt none gt BJ O lt CR gt
24. o be averaged After that the outputs occur at the same rate as the readings For example the command XYC2A outputs the moving average of the same data that would be output if the user issued the command XYC2 Since XYC2 outputs data once per second XYC2A also outputs once per second However the first output occurs after a four second delay in which the first four readings at a rate of 1 per second are averaged The second output is the average of readings 2 5 the third output is the average of readings 3 6 and so on creating an output rate equal to that of XYC2 The parameter x determines rate of continuous output as follows x 10 per second per second per second every 10 seconds every 60 seconds every 60 minutes every 12 hours 1 every 24 hours OA Average of 8 10 outputs sec data 10 readings are averaged 1A Average of 4 outputs second data 4 readings are averaged 2A or A Average of 1 output second data 4 readings are averaged YHOORWNEO PRPeRE wo Syntax ttssXYCx lt CR gt lt LF gt Error Strings None Default Off Persistence Once initiated continuous output remains in effect even with power cycle Setting is stored in nonvolatile memory Must be turned off using the XYC OFF command see below Example with SO SIM command 9900XYC1 lt CR gt lt LF gt response 00 699 000 070 020 290 N0000 S 00 699 000 071 020 309 N0000 S 00 699 000 071 020 313 N0000 S 00
25. oncondensing CONNECTIONS Three 60cm 2 ft cables included Signal H1 Power H2 Control Outputs H3 DIMENSIONS amp WEIGHT 67 x 67 x 25mm max 2 6 x 2 6 x 1 0 inches 31g 1 1 oz greater range available IRIS Tilt Switch Order Numbers Accessories amp Upgrades Part No Power Kit 100 240 VAC wall transformer Version RS232 RS422 485 pole cable WIN OETI 84091 High Gain 98021 03 98021 09 Critically damped sensor to filter vibrations VISCDAMP Standard 98021 01 98021 07 Mounting plate amp hardware 84089 Wide Angle 98021 02 98021 08 512 kB Flash memory upgrade 48543 1336 Brommer Street Santa Cruz CA 95062 USA Tel 831 462 2801 Fax 831 462 4418 applied geomechanics com e www geomechanics com B 06 1001 Rev A 2006 Applied Geomechanics Inc IRIS Tilt Switch and Controller A Full Featured Inclinometer IRIS is a versatile biaxial clinometer that measures rotational movement in two orthogonal vertical planes Serial ASCII data are output as either RS232 or RS422 485 signals for recording by an external terminal or computer Important features are firmware controlled and user selectable These include output data rates and formats signal averaging autozero nulling and internal data storage logging Several output data formats are provided all of which include X tilt Y tilt Temperature and Serial Number information
26. put per second data Once initiated continuous output remains in effect until turned off with the XYC OFF command see below Turns off XYC mode Enables control feature Disables control feature Sets the control pin high 5 VDC Sets the control pin low 0 VDC APPLIED NN GEOMECHANICS 3 INCORPORATED IRIS Tilt Switch and Controller XY SET THRESHOLD x x y y Sets the control thresholds The reference angle for threshold measurement is selected using the XY AUTOZ command XY SET HYST k Sets the control hysteresis XY DUMP SETTINGS Dumps settings of device XY DUMP2 Dumps extended settings of device 2 Setting the Control Thresholds The firmware commands for turning the control feature of IRIS on and off and for setting the control thresholds set points are summarized in Figure 6 and in Section 1 2 They are described in greater detail in Section 4 The reference angle for each control threshold is the zero angle as set by the autozero command XY AUTOZ If the unit is not autozeroed the reference angle is the zero angle set during the instrument s factory calibration If you plan to rotate IRIS in the X or Y direction only set the positive and negative X and Y thresholds using the XY SET THRESHOLD x x y y command If you need to detect a tilt threshold in any direction not just the X or Y direction set the General Alarm threshold H3 pin 8 Figure 6 in the following manner Set x y a
27. re or software flow control The baud rate is the only parameter that is user selectable The default baud rate is 9600 Baud rates up to 230400 are supported 1 1 Firmware Command Format The format of commands issued by the host is 9900 lt command gt lt CR gt lt LF gt Valid commands are listed in Section 3 The input output processing on the serial port of the IRIS circuit is as follows 1 Input is read until a lt CR gt or lt LF gt carriage return or line feed is received On a PC this usually means pressing the Enter or Return key 2 When a line is received it is parsed to see if it is a command of the device If it is not then it is echoed back out terminated with a lt CR gt lt LF gt and we go back to step 1 All strings that are not commands for the unit are echoed If the command is for the device we then go to step 3 3 The command is processed and we return to step 1 All incoming characters are buffered up to 1000 while the command is being processed If the command is for ID 99 and echoing of 99 commands is APPLIED SSS B 06 1001 Rev A 1 ae IRIS Tilt Switch and Controller enabled the command is echoed after the command result is transmitted Default output of the MD900 T running firmware version 5 and up is a simple SIM comma delimited string consisting of X tilt in degrees Y tilt in degrees temperature in C and the serial number of the device Optional outputs con
28. s None Default Off Persistence Setting is stored in nonvolatile memory Example command 9900XY TR PASH ON lt CR gt lt LF gt response lt none gt APPLIED B 06 1001 Rev A 9 GEOMECHANICS IRIS Tilt Switch and Controller XY TR PASH OFF Turns off translation of SPASHS XDR P sentences Syntax ttssxXY TR PASH OFF lt CR gt lt LF gt Error Strings None Default N A Persistence Setting is stored in nonvolatile memory Example command 9900XY TR PASH OFF lt CR gt lt LF gt response lt none gt XY EP Enables power on message Power on message is AGI Tiltmeter Firmware V5 2 SN N1212 IDO1 Where V5 2 is the firmware version SN N1212 is the serial number of the device and IDO1 is the target s ID Syntax ttssxXY EP lt CR gt lt LF gt Error Strings None Default On Persistence Setting is stored in nonvolatile memory Example command 0100XY EP lt CR gt lt LF gt response lt none gt XY SP Disables power on message Syntax ttssxXY SP lt CR gt lt LF gt Error Strings None Default N A Persistence Setting is stored in nonvolatile memory Example command 9900TR SP lt CR gt lt LF gt response lt none gt XY EE Enables echoing of global 99 commands If the unit receives a command for ID 99 then the unit will respond to the command and echo the command when it is done T Syntax ttssXY EE
29. s com B 06 1001 Rev A 2006 Applied Geomechanics Inc IRIS Tilt Switch and Controller H1 H1 CABLE SCHEMATIC H1 CABLE ASSEMBLY 2 GEOMECHANICS INCORPORATED Figure 2 H1 H1 CABLE SCHEMATIC H1 CABLE ASSEMBLY APPLIED GEOMECHANICS INCORPORATED Figure 3 1336 Brommer Street Santa Cruz CA 95062 USA Tel 831 462 2801 Fax 831 462 4418 applied geomechanics com e www geomechanics com B 06 1001 Rev A 2006 Applied Geomechanics Inc IRIS Tilt Switch and Controller H2 H2 CABLE SCHEMATIC APPLIED GEOMECHANICS INCORPORATED Figure 4 H3 CONTROL CABLE FOR IRIS PCA APPLIED NN ONTROL CABLE FOR GEOMECHANICS 7 INCORPORATED Figure 5 1336 Brommer Street Santa Cruz CA 95062 USA Tel 831 462 2801 Fax 831 462 4418 applied geomechanics com e www geomechanics com B 06 1001 Rev A 2006 Applied Geomechanics Inc IRIS Tilt Switch and Controller H3 PINOUT IRIS PCA i ma ea APPLHED ASS moe GEOMECHANICS INCORPORATED Figure 6 1336 Brommer Street Santa Cruz CA 95062 USA Tel 831 462 2801 Fax 831 462 4418 applied geomechanics com e www geomechanics com B 06 1001 Rev A 2006 Applied Geomechanics Inc IRIS Tilt Switch and Controller 1 Connectors and Pinouts Your IRIS Tilt Switch and Controller uses three connectors on the printed circuit assembly H1 H2 and H3 Pin assignments for the three connectors are shown i
30. sist of a Trimble Navigation proprietary ASCII string with X Roll and Y Pitch tilts in degrees and two output formats that follow NMEA Standard 0183 version 2 1 October 15 1995 This standard may be obtained from National Marine Electronics Association NMEA National Office P O Box 3435 New Bern NC 28564 3435 USA Tel 919 638 2626 Fax 919 638 4885 1 2 Firmware Command Summary The list below summarizes the most important user accessible firmware commands Precede these commands with the string 9900 See Appendix A for additional details XY Outputs a single tilt and temperature measurement The format of the output depends on the setting of the SO command SO xxx Selects the output format for the XY command xxx selects format as follows ASH Ashtech compatible NMEA format SIM Simple x y t sn output string default XDR NMEA XDR format TCM Trimble Navigation proprietary pitch Y and roll X string BAE BAE Systems encoded 11 byte string containing a sync packet x y t SN and checksum information Advanced users only typically for embedded system integration XY MEMS Stores tiltmeter readings at selected output rate in nonvolatile memory Versions 5 1 and higher XY MEMD Downloads data from nonvolatile memory Versions 5 1 and higher XY M1 Sets the tiltmeter to Mode 1 operation XYVR Displays the sign on string ID Sets the ID of units in the daisy chain not currently implemented XY TR