SurgeX SA-82-AR / XF2
Contents
1. eee 21 PAYLOADS see 23 Vill FIRMWARE UPGRADES 1 9 3 A9 9 OA IX RESET BUTTON A39 A X SPECIFICATIONS 25 SURGE SA 82 AR XF2 AR User Manual Page 1 Introduction The Su rgeX SA 82 AR XF2 AR is a network attached IP addressed web controlled AC surge protector and power conditioner The SA 82 AR XF2 AR may be used to switch up to 8A at 120V The simple web server structure allows basic control of two outlets The extensive programming and setup capabilities are accessed by a web browser through a Device Management Utility DMU or through a Command Line Interface CLI The SA 82 AR XF2 AR features SurgeX Series Mode surge protection Impedance Tolerant EMI RFI filtering and Over Voltage Shutdown Hemote reboot any device monitors routers servers kiosks etc The remote device need not be network attached Conserve energy by powering down equipment when not in use Telnet access uses the Command Line Interface CLI structure and syntax to completely configure and control the SA 82 AR XF2 AR This Axess Ready AR device also supports the DxP protocol which allows software developers to integrate the unit into custom applications Up to 2 systems can be continuously monitored with AutoPing with automatic power control upon loss of contact Reboot crashed systems or provide auto power up or down for environmental controls and notification systems The SA 82 AR XF2 AR utilizes
2. Online Help Opens a web browser to online help resources About Displays DMU version information SURGE SA 82 AR XF2 AR User Manual Page 5 energy intelligence II Initial Set Up continued Setting the IP Address ARs are configured with a factory default IP address of 192 168 1 254 To set the AR s IP address using one of the following methods the computer and AR must be on the same local network DMU Follow the steps in the preceding subsection to set the IP address using the Device Management Utility DMU CLI These are the basic commands to set the network parameters After setting these parameters the AR will need to be rebooted for the settings to take effect Any command that requires rebooting of the AR will provide a prompt to do so All commands may be entered as required before rebooting Manually specifying the IP address via CLI automatically sets the address as static Example Telnet to default IP address of 192 168 1 254 on default Port 23 SurgeX Axess Ready v1 01 41 User gt admin Password Axess Ready gt set ipaddress 10 1 2 69 Ok Axess Ready Reboot Required gt set subnet 255 255 255 0 Ok Axess Ready Reboot Required gt set gateway 10 1 2 1 Ok Axess Ready Reboot Required gt reboot The CLI command set ipmode dhcp followed by a reboot command may be used to configure the AR to automatically acquire its network settings from a DHCP server A DHCP server will automatical
3. SURGEX energy intelligence AXESS Ready Hardware Installation Guide Axess Ready Surge Protector Power Conditioner SA 82 AR XF2 AR SOFTWARE VERSION 1 01 41 FIRMWARE VERSION 1 01 06 SurgeX 517 North Industrial Drive Zebulon NC 27597 Customer Service 800 645 9721 Technical Support 800 645 9721 Fax 919 269 0454 www surgex com Table of Contents I INTRODUCTION 2 ll INSTALLATION 3 ETHERNET CONNECTION 5 5 5 5 LLLI 3 AC POWER CONNECTIONS U 0 3 LED INDICATORS 9 5 5 9 9 9 9 9 9 9 9h 9 9 95h LLLI 3 III INITIAL SETUP 4 DEVICE MANAGEMENT UTILITY DMU eee 4 SETTING THE IP ADDRESS itit u 6 IV OUTLET ON LED INDICATOR 7 V WEBSERVER 8 PASSWORD 8 CONTROL AND STATUS PAGE LLL LLL 8 SETUP PAGES LLL 9 DEVICE eee 9 NETWORK eee 10 AUTOPING eee 11 SCHEDULE 1 5 LLL 13 PASSWORD 14 VI COMMAND LINE INTERFACE CLI PROTOCOL 15 PROMPTS 0 0 0000000 0000000 022200 2 15 CONTROL COMMANDS LLL 15 DEVICE COMMANDS si 15 NETWORK COMMANDS Lue 16 AUTOPING COMMANDS J eee 17 USER COMMANDS _ 5 9 9 9 5h LL a snn 17 EVENT COMMANDS 5 5 5 9h 9 9 9h LLL LLLLLLLLLLLLL L LL 18 VII DxP PROTOCOL 19 OVERVIEW eee 19 HELLO HANDSHAKE 211 2 LLL 19 DXP PACKET 5 5 5 5 5 5 95 9 95 95 9h 9h LLL 20 COMMANDS LLL 21 DESCRIPTORS
4. lt new gt repeat Sets the password of the User or user ME admin Administrator SURGEN SA 82 AR XF2 AR User Manual Page 17 energy intelligence Vi Command Line Interface CLI Protocol continued Event Commands Command j Descipion CS Admin Fact Def get events Returns all scheduled events currently in use Example NO Date Time Repeats Action 12 22 2011 14 00 every 2 Hour s Cycle every On I every every I every every I every every get time Returns the current time and time server Example No Current Time 10 14 17 12 20 2011 Server 10 1 2 12 Ok set time server lt dotted decimal gt Sets the IP address of a Network Time Server 64 90 182 5 5 set time enable lt yes no gt Enables or disables the use of a time server and scheduled evenis set event lt 1 8 gt date lt mm dd yyyy gt Sets the scheduled event s starting date g set event lt 1 set event lt 1 8 gt time lt hh mm ss gt gt time lt hh mm set event lt 1 8 gt time lt hh mm ss gt gt Sets the time the scheduled event will occur in 24 hour format the time the scheduled event will Sets the time the scheduled event will occur in 24 hour format in 24 hour format set event 1 8 repeat day hour Sets the repetition interval type for the selected event minute gt set event lt 1 8 gt mult lt 0 999 gt Sets the number of repetition intervals for the selected event
5. 2 levels of password security with only the administrative account having access to setup and configuration Located on the rear panel are the input IEC power plug network connection RJ 45 8A circuit breaker and output receptacles The front panel contains the Outlet On LED Self Test LED System On LED and Reset button SURGEX SA 82 AR XF2 AR User Manual passe energy intelligence pa ll Installation Ethernet Connection The RJ45 connector for 10 100 Ethernet is situated on the rear panel beside the input power plug The default IP Address is 192 168 1 254 AC Power Connections Connect the device to be powered On and Off to the output duplex receptacle Ensure that the total combined load of all controlled devices does not exceed 8 Amps Connect Equipment Connect one end of the supplied power cord to the connector labeled AC Input and the other end to a properly grounded AC outlet LED Indicators uswa NN The green Self Test LED indicates that the internal surge protection circuitry is fully functional The red Outlet On LED indicates that power is being supplied to the two receptacles The red System On LED indicates that the Axess system is On This indicator will turn off if the AC voltage rises above 145V and AC power will be removed from the output receptacles in order to protect connected equipment When the AC voltage returns to below 135V power will au
6. For example 20 days 30 minutes 24 hours etc set event lt 1 8 gt action lt on off cycle gt Sets the action to be performed at the scheduled time Yes del event lt 1 8 gt Deletes the scheduled event Yes SUR GEX SA 82 AR XF2 AR User Manual Page 18 energy intelligence 1 2 3 4 5 6 7 8 O 2 Vil DxP Protocol Overview The DxP Protocol is a packet based protocol designed to be extensible This protocol is transmitted over TCP on a user defined port The factory default DxP port is 9100 The protocol uses a Hello handshake to establish unique sequence numbers to allow for advanced security when AES encryption is used With AES enabled all messages must be encrypted with the AES Passphrase set in the device After the Hello a Command and Response sequence follows Any number of Command Response sequences are permitted after Hello Hello Handshake The client sends a Hello message in the form of a text string hello O00 The DxP enabled device will respond with a packet containing the unsigned 16 bit sequence number This sequence number is incremented by the client and server with each correct packet sent Example hello 000 Server 1234 seq 1234 Response Response Command seq 1237 w __ FPuwww lt Ss seq 1235 Z C L e SURGE SA 82 AR XF2 AR User Manual VI DxP Protocol Continued DxP Packet The packet is broke
7. cycle press either Power On or Power Off and the outlets will assume that status If the AutoPing feature is in use this page will also display the current status OK or Failed for each AutoPing a counter of how many times the ping failed and a counter of how many times the defined action was triggered Reset buttons for the Fail and Trigger counters are available for the admin login Use the Refresh button to update the page with the most current status Use of the browser s refresh button may lead to inadvertent power switching If an NTP time server is being used the time of the last refresh will be displayed in the upper right corner SURGEX SA 82 AR XF2 AR User Manual Page 8 energy intelligence uM Web Server Continued Setup Pages Setup pages are only available while logged in with Administrator credentials Press Save to save the new settings If the new settings require the AR to be rebooted a Reboot button will appear at the bottom of the page Settings requiring reboot will not take effect until the unit is rebooted Device Location ID Specifies a name label up to 20 characters that will be displayed at the top of all pages Assigning unique names is helpful for management of multiple units Cycle Time Specifies the length in seconds of a power cycle 1 999 seconds This is the amount of time the outlet will temporarily be On or Off depending on the initial outlet state Upgrade Enable Enables
8. 3 MHz 50 dB 30 Filter MHz Common Mode 50 O 18 dB 300 kHz 30 dB 1 MHz 50 dB 5 MHz 50 dB 220 load MHz Compliance w s UL cUL UL60950 Listed l T E File No E225914 UL 1449 3 Edition In Progress Directives 89 336 EEC 92 31 EEC and 93 68 EEC EN 60950 3 Edition EN55022 1998 Class B FCC Part 15 Class B Network S O Internal HTTP Web Server 1 2 x 50 us pulse industry standard combination wave surge as per IEEE C62 41 SURGE SA 82 AR XF2 AR User Manual Page 25 energy intelligence
9. Cmnd get eCmnd io eCmnd keepAlive eCmnd rss eCmnd rcu eCmnd Cmnd null This is a null command and should not be sent to the server C 0 je L Server Server Cmnd io client to validate the communications path to the server This command class is used to control the RSS nest using the RCU Note Project specific command Not for general use eCmnd rcu This command class is used to update the display of the RCU O Note Project spectic commana Not for general use Descriptors Descriptors are used to describe the individual command within a command class and the payload that the packet contains All of the descriptors and their payloads are outlined by command class below eCmnd set The descriptors for this command class will be product specific eCmnd get The descriptors for this command class will be product specific SURGEX SA 82 AR XF2 AR User Manual Pada energy intelligence VI DxP Protocol Continued eCmnd io typedef enum elO_ null elO_changeRelay elO_changeRelays elO_getRelay elO_getRelays elO getlnput elO getlnputs elO pulseRelay elO elO changeRelay This command is used to change the status of an 0 Successful individual relay It carries the TChangeRelay payload 1 Error see the Payloads subsection for details elO changeRelays This command is used to set all of the relays in a device 0 Successful It carries the TChangeRelays paylo
10. SURGE energy intelligenc Examples e e Server monitor AR is installed with the device it monitors and automatically reboots if there is no response Ideal for Kiosks and Servers Service monitor AR is installed with ulum the device to be rebooted but pings a B remote host to test the communication nc channel Ideal for DSL Cable Modem AutoPing Service Verification verification AR monitors a network device and powers up an alarm or redundant O_ o EENE system when there is no response m Il Ideal for Hot Standby Servers E Environmental Control Alert for any AutoPing Alert Generator network failure IP Address 1 and 2 Enter the IP address es of the device s to be pinged Frequency 1 and 2 Enter the desired ping frequency in seconds for the device s to be pinged 1 999 seconds Fail Count 1 and 2 Enter the number of times the ping must consecutively fail 1 999 before the selected action is triggered Mode Select the logic to be used AND OR or Single With AND logic both AutoPings must exceed their fail count to trigger the action With OR logic the action will be triggered if either AutoPing exceeds its fail count With Single only AutoPing 1 is used SA 82 AR XF2 AR User Manual Page 11 m O V Web Server Continued e Action Select the action to be triggered None changed via web telnet or DxP response returns AR will power off c
11. ad see the Payloads 1 Error subsection for details elO getRelay This command has not yet been implemented DJ elO getRelays This command is used to get the status of all the relays Byte Array on the server containing status of each relay elO getlnput This command has not yet been implemented LC elO getlnputs This command is used to get the status of all inputs on Byte Array of each input elO pulseRelay This command is used to pulse a relay It carries the 0 Successful und occ LA details eCmnd keepAlive typedef enum eKeepAlive null eKeepAlive eKeepAlive null This is the only valid descriptor that the keep alive 0 Successful command supports It is defined as null as it carries no 1 Error payload SURGE SA 82 AR XF2 AR User Manual Page 22 energy intelligence VI DxP Protocol Continued Payloads TChangeRelay typedef struct unsigned char relay unsigned char state TChangeRelay Where relay is the number of the relay to be affected 1 For example 0 for relay 1 and 1 for relay 2 and state sets the state of the relay 1 Energize 2 Relax TChangeRelays typedef struct unsigned char relayStates 32 TChangeRelays Where relayStates is an array of relay states as defined below define NO CHANGE 0 define ENERGIZE 1 define RELAX 2 This payload is supported by devices that support the DxP protocol with 2 32 controllable relays TPuls
12. eRelay typedef struct unsigned char relay the relay to be pulsed unsigned char state the state to pulse uint16 pulseWidth the pulse width in seconds TPulseRelay Where relay is the number of the relay to be affected state is the state to pulse and pulseWidth is the time to pulse in seconds SURGEX SA 82 AR XF2 AR User Manual Page 23 energy intelligence Vill Firmware Upgrades The AR can be upgraded via the network if the upgrade feature has been enabled To perform a field upgrade follow the steps below Important Upgrading the firmware with a minor upgrade For example 1 01 xx to 1 01 yy will not alter the user defined settings Major upgrades may or may not reset the AR to factory defaults Check the release notes for the upgrade before making any changes 1 Download the latest firmware version and Device Management Utility DMU from the SurgeX website http www surgex com 2 Enable the upgrade feature Use the CLI set upgrade enable yes command via telnet or check the Upgrade Enable box on the Device web page 3 Run the DMU If the AR you would like to upgrade is not visible in the list box either e Select Device Discover from the menu to locate the ARs on the local network e Select Device Add from the menu to manually add the AR by IP address Once the device is displayed in the list highlight it 4 Select Manage Upgrade Firmware Enter User Name admin and the password f
13. en set to 0 the DxP service is disabled May not be disabled when Web and Telnet are both disabled set timeout 0 999 gt Sets the automatic network timeout in minutes SUR GE SA 82 AR XF2 AR User Manual Page 16 energy intelligence 192 168 1 254 255 255 255 0 192 168 1 1 Vi Command Line Interface CLI Protocol continued AutoPing Commands Command I Deseription ____________ Admin Fact Det get autoping Returns all AutoPing settings currently in use Example AutoPing 1 AutoPing 2 IP Address 10 1 2 36 0 0 0 0 Frequency 60 Fail Count 3 Status OK Trigger Count 0 Mode Single On Latch set autoping lt 1 2 gt ipaddress lt dotted decimal gt the IP address to be pinged for AutoPing 1 or 0 0 0 0 set autoping lt 1 2 gt frequency lt 1 999 gt Sets the frequency how often the ping is sent for AutoPing 1 or 2 in seconds set autoping lt 1 2 gt failcount lt 1 999 gt Sets the number of consecutive failures the AutoPings must detect before the AutoPing considers the pinged device to be failed set autoping mode lt single and or gt Sets single AutoPing AutoPing 1 or two AutoPing Yes relationship AND or OR set autoping action lt none on latch on follow off Sets the action to be performed when the AutoPing Yes None latch off follow cycle cycle once gt is triggered User Commands set password lt user admin gt lt old gt
14. hanged via web telnet or DxP response returns AR will power on Power Cycle Upon triggering AR will cycle the power AR will then wait for Ping Frequency x Fail Count seconds if the response does not return the power will be cycled again This will repeatedly continue until the ping response returns or AutoPing is turned off Ensure that the AutoPing frequency is longer than the time required to reboot the device Power Cycle Once Upon triggering AR will cycle power one time It will not cycle again automatically until the ping response returns and is lost again QU f 10 1 116 set ap html Vi Attached to Axess Ready AutoPing Settings AutoPing 1 AutoPing 2 IP Address 10 1 2 12 Schedule Frequency 20 10 Passwords Fail Count 3 B Home x Mode Action Save Reset Surgex Axess Ready v1 01 41 SURGEN SA 82 AR XF2 AR User Manual page energy intelligence Schedule The AR can schedule up to 8 recurring power events For each event you may define the starting date and time the action to be taken and the repetition interval optional Important A Network Time Server NTS must be specified and enabled in order to use the time scheduling feature A list of public time servers is available at hito www ntp org Enable Checking the Enable box enables the time scheduling feature Time Server Enter the IP address of the Network Time Server to be used Time Zone Spec
15. ifies the local time zone relative to GMT For example the setting for EST is 5 Date Set the initial date for the event in mm dd yyyy format Time Set the initial time for the event in hh mm ss format Hours are specified in 24 hour format for example 8 05 00 pm would be entered as 20 05 00 Hepeat Optional Set the repetition interval 0 999 Days Hours or Minutes Action Set the action to be scheduled On Off or Cycle Clear Deletes a schedule Attached to Axess Ready Schedule Settings Enable Iv 08 07 07 07 13 2012 Time Server 64 90 182 55 Time Zone 5 Date Time Repeat Action o Day s On Clear SurgeX Axess Ready v1 01 41 SURGEN SA 82 AR XF2 AR User Manual pana energy intelligence SURGEN energy intelligence Passwords Two passwords are used by the AR The User password allows control of the AC receptacle state but provides no access to Setup functions The Administrator password allows full control and setup of the AR Passwords may be up to 20 characters long and are case sensitive e Old Password Enter the password currently in use e New Password Enter the new password to be used e Confirm Password Enter the new password to be used again Default credentials Role Username fixed Password user set Administrator admin admin User user user X surgeX Axess Ready lt C fi 10 1 2 116 set_pass html Attached to Axess Ready Password Set
16. ly assign an IP address dynamic address as well as the Subnet Mask and Gateway To determine what IP address has been automatically assigned by the DHCP server you will need to use the Discover feature of the DMU or query your DHCP server and locate the MAC address of the AR in the DHCP server s IP MAC table Web To set the IP address using a web browser navigate to the current IP address of the AR 192 168 1 254 if the unit is in a factory default state Enter the administrator credentials Factory Default User admin Password admin click on Setup then click on Network and follow the directions in the Web Server Network Setup section of this manual SURGE SA 82 AR XF2 AR User Manual Page 6 energy intelligence The Outlet On LED functionality is as follows LED State On Solid On Blinking Off SURGEX energy intelligence The outlets are On button will restore the AR to a factory default state The outlets are Off The Reset button has been pressed for 5 or more seconds Releasing the SA 82 AR XF2 AR User Manual Page 7 pet E V Administrator admin admin User user user Web Server The Axess Ready web interface provides the easiest means of operating the outlet and changing configuration parameters To access the web interface open a web browser and enter the IP address of the AR into the address bar The factory default IP address is 192 168 1 254 Pass
17. n number the current IP a address and the MAC address Factory 4 as ps po 7 defaulted ARs will display with the name New SX iPD and have either the factory default IP address of 192 168 1 254 or an xi IP address that was automatically 2 ce assigned by the DHCP server on your Co network If the IP address was assigned by a DHCP server no changes to the IP address are required IP address successfully set The IP address field also indicates the port for web access that is currently in use by the AR The standard port for web browser accessibility is factory default Port 80 Add Manually add an AR by IP address Clear Clear the list SURGEN SA 82 AR XF2 AR User Manual paged energy intelligence II Initial Set Up continued Manage Set Exit Help Open Browser Opens the web browser interface for the selected AR Upgrade Firmware Starts the Firmware Upgrade dialogue Firmware Upgrade requirements Valid firmware file Administrative login credentials Upgrade Enable must be set to yes set via web page or CLI IP Address Changes the IP address of the selected AR Factory Defaults Return the selected AR to a Factory Default state This action must be performed within the first 2 minutes after powering up the unit Local Address Select the IP address to Discover on This may be necessary for computers with multiple network connections Exits the DMU program
18. n up into 2 parts the Header and the Payload Header The header is used to carry general information such as is shown in the C programming structure below typedef struct eCmnd command char 21 uName char 21 password uChar desc uChar param uint16 seq THeader sent See the Commands subsection for a full list of command classes Reserved for future use It will contain the user name of a user on the iplO that is being accessed Reserved for future use It will contain the password of the user above different set of descriptors for each command class see the Descriptors subsection for a full list of descriptors by command class param Reserved for future use Optional parameter that may be passed to the server in addition to the descriptor The packet s sequence number Used as part of the security scheme desc Command descriptor that describes the individual command within a command class By extension it lets the server know what the payload is There is a Payload The payload is determined by a combination of the command class and the descriptor The payloads are described with the descriptor see the Descriptors subsection for details SURGEX SA 82 AR XF2 AR User Manual ON energy intelligence VI DxP Protocol Continued Commands There are currently 7 command classes All classes are defined in the C programming enumerated type definition below typedef enum eCmnd null eCmnd set e
19. or the Administrator Enter the filename of the new firmware or click Browse and navigate to the firmware file to be used AR firmware files use the file extension g2u If no files of that type are displayed ensure that the Files of Type box is set for SX iPD or All Files Click OK when all details are entered 5 he upload will begin and a progress bar will be displayed 6 When the firmware upload is complete the AR will automatically reboot and will be ready for use IX Reset Button The recessed reset pushbutton located on the front panel performs 3 functions as detailed below E Soft Reset Will not affect outlet state then release powering up address of 192 168 1 254 SURGE SA 82 AR XF2 AR User Manual Page 24 energy intelligence Physical 00 S OSOS 5 to 95 R H non condensing AC CO Load Rating 8 Amps 120 Volts Power Requirement no load 10 Watts UL 1449 2 Adjunct Classification 1000 surges 6000 Volts 3000 Amps C1 pulse measured Test Results suppressed voltage 290 Volts no failures Maximum Applied Surge Pulse Unlimited due to current limiting 8 x 20 us Joule Rating Maximum Applied Surge Pulse 6000 volts 1 2 x 50 us pulse industry standard rating Voltage Maximum Applied Surge Pulse Unlimited due to current limiting 8 x 20 us Current Endurance Pulses Overvoltage Shutdown EMI RFI Normal Mode 50 Q load 40 dB 100 kHz 50 dB 2300 kHz 50 dB
20. rmat This field will be automatically set if using DHCP Gateway Enter the Gateway in dotted decimal format This field will be automatically set if using DHCP HTTP Port Specify the port the web server will be accessed on If the port is changed from the default value of 80 the AR may be accessed by specifying the new port number in this format http IPADDRESS NEWPORT Example Navigate to http 192 168 1 254 8000 for an IP address of 192 168 1 254 on port 8000 Telnet Port Specify the port to use for telnet access default 23 DxP Port Specify the port to use for DxP protocol default 9100 C f 10 1 2 116 set_net html Ww Attached to Axess Ready Network Settings IP Mode Static IP Address 012436 Subnet Mask 2552552550 Gateway HTTP Port fo Telnet Port Ps DxP Port Bio Surgex Axess Ready v1 01 41 SA 82 AR XF2 AR User Manual Page 10 j I V Web Server Continued AutoPing The AutoPing feature allows the AR to automatically detect failed equipment and perform a timed reboot or other power control function like turning on an indicator or siren First specify one or two IP addresses to be periodically pinged When the AR no longer receives a response from these addresses the programmed power control function is actuated AND or OR logic can be applied to the two addresses so that both AND or either OR must fail in order to trigger the selected action
21. s the upgrade enable status Disabled set upgrade enable lt yes no gt Enables or disables the ability to upload new firmware Ye logout Terminates the telnet session IGNI SUR GEX SA 82 AR XF2 AR User Manual Page 15 energy intelligence Vi Command Line Interface CLI Protocol continued Network Commands get network Returns all network settings currently in use Example Mode DHCP IP Address 10 1 2 69 j D o Subnet 255 255 255 0 Gateway 10 1 2 1 HTTP Port Telnet Port DxP Port Timeout Ok set ipmode lt static dhcp gt Sets the IP address mode Static mode locks the IP Yes otatic address as set DHCP mode allows a DHCP server to assign the address set ipaddress dotted decimal gt Sets the IP address Yes set subnet dotted decimal Sets the Subnet Mask Yes set gateway dotted decimal Sets the Gateway address Yes set http port 0 65535 Sets the port that the internal Web server listens for Yes incoming connections on When set to 0 the web server is disabled May not be disabled when Telnet and DxP are both disabled set telnet port lt 0 65535 gt Sets the port that the internal Telnet server listens for Yes 23 incoming connections on When set to 0 the Telnet server is disabled May not be disabled when Web and DxP are both disabled set dxp port 0 65535 gt Sets the port that the internal DxP service listens for Yes 9100 incoming connections on Wh
22. the ability to upgrade the firmware of the AR Auto Logout Specifies the inactivity timer duration in minutes 0 99 minutes If there is no activity after the specified amount of time the user will be automatically logged out Setting the timer duration to 0 disables the timeout feature Important As the AR allows only one web user logged in at any time use caution when disabling the timeout feature as it is possible to lock out other users by forgetting to log out Closing the web browser will not log the user out and will lock out web access In this situation it will be necessary to access the AR via telnet and reboot the unit _ A 10 14 M 2 116 set device html p Attached to Axess Ready Device Settings Network Location ID Axess Ready _AutoPing Cycle Time 10 Seconds Schedule Upgrade Enable D Passwords Passwords Auto Logout P Minutes Home Save Reset SurgeX Axess Ready v1 01 41 SURGEN SA 82 AR XF2 AR User Manual Based energy intelligence W SURGE energy intelligenc V WebServer Continued Network e e IP Mode Select Static to manually set the IP address using the fields below or choose DHCP to allow the AR to automatically acquire its network settings from a DHCP server IP Address Enter a static IP address in dotted decimal format This field will be automatically set if using DHCP Subnet Mask Enter the Subnet Mask in dotted decimal fo
23. tings User Admin Old Password New Password Confirm Password Save Reset Surgex Axess Ready v1 01 41 SA 82 AR XF2 AR User Manual Page 14 Vi Command Line Interface CLI Protocol The Command Line Interface provides complete setup of all functions of the AR The CLI may be accessed through the Telnet protocol and requires a Telnet client program Some commands of the CLI require administrative rights these are indicated in the following tables Prompts Prompt CS Description 33 Prompts the user to enter the user name either user or admin SX iPD gt Prompt displayed while logged in SX iIPD Reboot Required gt Prompt displayed after changes have been made that require a reboot This prompt will remain active until the AR has been rebooted Control Commands Command Description 9 Admin FactDef get outlet Returns the current status of the outlet INI set outlet on off cycle gt Sets the outlet to the selected state INI Device Commands Command jDescipion Admin FactDe f get location Returns the location ID Yes New SA 82 AE s set location lt 20 character max gt Sets the location ID Y get cycle Returns the cycle time currently in use in seconds set cycle lt 1 999 gt Sets the cycle time in seconds Y get upgrade enable Return
24. tomatically be restored to the output receptacles and the System On LED will turn on SURGE SA 82 AR XF2 AR User Manual Page 3 energy intelligence Il Initial Set Up Device Management Utility DMU Y Device Management Utility I xl Device Manage Set Exit Help Th e S u rg eX D evice M an aQ ement U tl Ity D M U leady ES a Al x 116 80 CEHE F2 8F provides the easiest means to find and configure your AR for use The DMU can 1 Automatically discover multiple ARs on a local network 2 Display the current IP address of each AR 3 Allow the setting of a new IP address for each AR 4 Perform firmware upgrades 5 Return an AR to Factory Defaults DMU automatically discovers devices on the local network g j gt i Device Manage Set Exit Help The SurgeX Device Management Utility is available Z OEE RO on th e A R C D or on th e S u rg ex we bs ite at Axess Ready SX4PD 1 01 41 10 1 2 116 80 00 0D AD 01 F2 8F http www surgex com x Enter the new IP Address for SX iPD Axess Ready MAC Address 00 0D 4D 01 F2 8F Note The IP address can only be set within the first zn 2 minutes after powering up the AR The utility will ok ces only work with ARs on the same local subnet as the PC Enter new IP address for selected Axess Ready Device Discover Automatically discover all ARs on the local network The DMU will display the location name of the AR the product ID and versio
25. word The AR uses two username password credential sets one for normal power control user and one that also provides access to the Setup functions admin Default credentials Username fixed Password user set Authentication Required The server 10 1 2 116 80 requires a username and password The server says SurgeX Axess Ready UserName ss s Password Enter a valid username and password when prompted When the proper username password combination is received the Control and Status Page is displayed Control and Status Page Once a user is validated the Control and Status page is displayed 01216 Note Only one user may be logged in to the AR at a Attached to Axess Ready e isesza ciae Power ON Power OFF Cycle Power Press Power On or Power Off to turn the AC output ae On or Off In the event of a power outage the AC output will return to its last known state prior to the outage Press Cycle Power to temporarily change the state of the AC output for a specified cycle time factory default is 10 seconds The cycle operation performed will either be On Off On or Off On Off depending on the initial state of the AC output During the power cycle operation the Power Status bar will indicate the temporary status with a Blue background Once the cycle is complete the status bar will revert to its original condition To abort a power
Download Pdf Manuals
Related Search
Related Contents
2.4GHz ActivSlate Quick Start Guide Ethernet Dual SerialBridge™ Ethernet Fiber Dual DDL-8700 CONSIGNES DE SECURITE (FRANÇAIS) APC J25B uninterruptible power supply (UPS) RCA 25250RE1 User's Manual 取扱説明書 - M Sencor SLE 40F10M4 LED TV Diaphragm Valves Type 15 GE GSD5900 Dishwasher Copyright © All rights reserved.