1. Intelligently digital conference system User Manual TS 0604M Before using the system please read this manual first This manual only as an instructions for user not for service purposes From the date of issue if the function or technical parameters change later another supply mentary instruction will be added the details can be inquired to the manufacturers This manual is a product manufacturer Copyright unauthorized and any entity or individual shall not take part or all the contents as commercial purposes This manual used for intelligent digital conference system N SAFETY OPERATIONAL GUIDANCE SSSSSSSESSESSSSESSSSSSESSSSSSSESESSSESESSSSESSESESSSESSESESESS In order to make sure the correct operation and safety using please comply with the following conditions when installation operating and maintenance 1 Make sure the connection of the ground wire is well enough when installation Do not use two core plug And make sure the input voltage of power supply is as same as the one marked on the main controller Do not open the cover of the unit without permission especially the high voltage components marked with AC 100V to 240V or there is risk of shock Do not put the unit in extremely cold or hot place The unit will be heating when working Please keep environment ventilation to avoid overheating Please power off the unit in wet weather or not in use Please disconnect the AC power wiring from the
2. power indicator light will be out 8 power indicator 3 2 Back Panel Q LINE ig a 1 2 3 4 5 6 7 8 9 1 POWER INPUT Input power support AC100V 240V input 2 SET ID conference unit ID set up switch use for set the conference unit s ID Complete ID set after 20 seconds before the next step 3 PC Connected to computer serial port PC software conference management function 4 CONTROL SYSTEM Connect the central control system controller or camera tracking controller automatic camera tracking function 5 DELEGATES Used to connect to conference unit each controller can connect to 128 unit maximum 6 ROUTE Extension socket connection can realize more hand in hand extension controller in series connection 7 OUT port Connect to a remote conference call terminal input including conference audio and line input audio 8 REC port Record output connect to monitor recording machine 9 IN port Line audio input such as background music or remote conference call terminal output 1 Unit 8 core air connector foot function description 8Pin MALE 485 1 1 485 8 SOS 8 GND 2 2 jM oam A 5 5 Ap de m B 7 7 24V 4 4 2 CONTROL SYSTEM COM foot position function description Foot Signal Descrip
3. AC power supply before the below operations A Remove or re assembly any parts of the unit B Disconnect or re connect any plug of the unit or other connection Non professionals without permission please do not attempt to open the enclosure do not repair in order to avoid the accident or exacerbation of equipment damage degree Don t take any corrosive chemical powders or liquids spilled in the equipment or in the vicinity of 1 Intelligent digital conference system overview About ITC intelligent digital conference system Intelligent digital conference system the control of products and multimedia audio and video matrix product after high tech professional product series which including discussion simultaneous interpretation the infrared voice distribution long distance telephone meeting voting and camera tracking system Always advocated the concept of a comprehensive system integration solutions which can do DCS digital conference system MCS multimedia central control system closely compatible between the two different systems formed a product of comprehensive intelligent conference system solution This manual is suitable for the intelligent conference system of master controller speech unit camera tracking system and telephone conference system 2 Function characteristics Conference controller can connect to 128 units at maximum through expanded controller A completed conference system can ac
4. cess to 4096 units Using special 8 core aviation plug connection Hand in hand concatenated model With audio input connector With multiple sets of the original sound channel output Speak limit function a unit quantity 1 2 4 6 adjustable chairman of the unit is not restricted Support FIFO NORMAL FREE APPLY a variety of conference model Support automatic camera tracking function Cooperate with phone couple can be remotely conference call Support sign in voting and data management capabilities Support for PC software conference management functions Controller use metal shell with 8000V antistatic ability Controller can be installed on the 19 standard rack 3 DSC controlled system Description of Product TS 0604M Conference master controller 3 1 Front Panel 9 81 e We o 85 o o o FIFO NORMAL FREE APPLY One T T sly 1 2 6 7 8 1 MODE Setting FIFO Mode The first open speech unit was shut down by later speech unit after reaching boot number Normal mode After reaching representatives spoke unit number if representative speak Automatic enter request to speak Only first speck unit is turned off the request to speak unit will be speaking Free mode 20 representatives spoke unit number at the same time open up allowed in
5. e sign in Recruit sign in Outout nroiection NOAHYTC 001 The first sign in W Stetsignin Close sign in Figure 4 5 connection example TS 0622A SB 9 5 0622 5 0622 5 0622 S 6 Technical parameters Technical parameters TS 0604M Supply power Switching power supply AC100 240V Quiescent dissipation 10W Maximum power 350W Output power lt 110W 24V every road Audio output Impedance 1000 way nonequilibrium MIC input impedance 100kQ electronic level 60 dB way nonequilibrium Frequency response 60 16kHz Signal to Noise 80dB Ratio S N Harmonic distortion 0 5 carrier distortion lt 1 Weight About 4 8Kg Size 484L x 305W x88H mm Color Black
6. he end of a voting voting is completed 5 Priority Chairman unit specific priority TS 0622 click this button may be can celled all speaking unit at any time And then open the MIC of the chairman of the unit 6 Headphone output and audio output Conference through computer input the background music when the unit TS 0622 TS 0622A without open MIC speech function TS 0622 0622A through own trumpet making noise Once open MIC speech function trumpet music stop output Without opening MIC speech function if an earphone or recording interface trumpet will be muted audio output from the headphones and audio Conference fie Preparation before meeting Start conference Sortafter meeting System administer Assistant Help Figure 1 8 Max number of active MIC O2 MIC mode setting NORMAL FREE APPLY MIC control Turn off all MIC j Volume control 2dB 008 2dB 0dB 208 6 VOLUME r 15dB 10dB SdB 3dB Figure 2 ListOfMemberAskngTea 2 D Status Figure 3 Key press sign control az Start key press sign in Start sign in Keep on sign in at eet Close sign in Control sign in Recruit sign in Output projection Check unsign in detail Long distance sign in control Start long distance sign in Start sign in keep on sign in Clos
7. hone control volume control and other functions After finish the installation click exit enter the main interface of software 3 Sign in before the meeting Open the PC software ON the computer Click the sign in control figure 1 and then enter the sign in control interface ON the right to choose sign in model check in then click the start check in figure 3 enter the sign in projection screen press F2 to computer the cursor moves to the lower left corner appears fast control menu select the check in option figure 4 where the red light ON the microphone and TS 0622 TS 0622A ON OFF lights flickered ON When press the microphone button ON OFF button the light is normally ON the key You can see the projection of the above data 7 have change Click the end of the sign in the sign in is completed 4 Proposal Voting Open the PC software ON the computer then click the sign in control figure 1 enter the sign in control interface ON the right to choose sign in model check in then click the start check in as shown in figure 3 enter the sign in projection screen Press F2 to computer the cursor moves to the lower left corner appears fast control menu choose proposal option as shown in figure 4 where the red light ON the microphone and TS 0622 TS 0622A ON OFF lights flickered ON When press the microphone button YES ON button the light is normally ON you can see the projection of the above data changed Click t
8. maximum Apply mode representatives spoke unit should get permission of the chairman or the operator to speak P S chairman Not restricted by the above model 2 ACTIVE MICRO S A number of restrictions adjustable to the number of delegates unit at the same time open for 1 2 4 6 FREE mode is not restricted by this feature the chairman on behalf of the unit is not restricted 3 BASS Bass output volume adjustment through the volume buttons to adjust the output volume increase and decrease press the volume increase decrease key to control the volume increase decrease volume after the maximum minimum to continue button is invalid 4 TREBLE Adjust output volume treble through the volume buttons to adjust the output volume increase and decrease press the volume increase decrease key to control the volume increase decrease volume after the maximum minimum to 3 continue button is invalid 5 VOLUME Adjust output volume through the volume buttons to adjust the output volume increase and decrease press the volume increase decrease key to control the volume increase decrease Maximum volume OFF after the continue button is invalid 6 OFF Main volume mute lamp when the volume adjustment choose to OFF position the mute indicator light the main volume be turned OFF 7 power switch can open close the controller power supply Switch on power the power light is display switch power supply shut down the
9. tion position 1 2 Control 3 TXD Transmitter System data 4 Z 5 GND Signal earth 3 PC COM foot position function 6 description 7 8 Foot Signal Description position 1 2 TXD Transmitter PC data 3 RXD Receive data 4 5 GND Signal earth 6 7 8 4 Operating Instructions According to the following basic equipment and cable connection system A PC computer 1 conference controller TS 0604M 1pc C Embedded Unit TS 0622 TS 0622A 2pcs D 2 meters reticle 2pcs After connection please open the controller 1 Set ID Open controller The SETID switch to ON then ID can be set up Then press ON OFF key of TS 0622 TS 0622A light flashing ON the microphone And then keep red show that the unit ID to succeed then press the unit ON OFF button Set up is completed SETID switch to OFF all the lights out on the microphone ID set successful 2 Control in before the meeting firstly open computer and conference controller PC via a serial port line connection open the PC software intelligent digital conference system click on the conference control Open the PC software on the computer Click the conference control figure 1 enter the conference control interface the interface on the right side of the operation button can control the controller function figure 2 you can set the open microphone maximum number set the microphone mode microp

Download Pdf Manuals

image

Related Search

Related Contents

1 Preparar 2 Conectar  Manual de Instalação e Configuração VPN Anima  KOHLER K-1337-HN-96 Installation Guide  User Manual  GREAT FOR ALL SEASONS!  Tiger AS LT MT XL Betriebsanleitung    easyTEMP temperature sensor for easyTRACK „F” module version  EFI Production Backlit Supernova  Enjoy it. - BLAUPUNKT  