Home

GREAT FOR ALL SEASONS!

image

Contents

1. Always use parts that are supplied or approved by Airmax Inc Use of other parts may result in poor performance and could create a hazardous situation e Always unplug the system from the outlet and refer servicing to a qualified electrician under the following conditions 1 When the power cord is damaged or frayed 2 If the compressor is producing unusual noises or odors Your KoiAir compressor will need a maintenance kit KoiAir 1 Item 510145 KoiAir 2 Item 510146 every 12 36 months depending on operating depth air quality and operating temperature If your compressor is operating but there is no air coming out of the diffusers you will generally find that it is time to replace your diaphragm No maintenance required Replace membrane sticks 510168 if visibly damaged or if system has poor performance Unscrew the cover on the back of the compressor to expose the air filter Remove the air filter and brush away any dust particles Air filter should be replaced every 6 months KoiAir 1 510153 KoiAir 2 510149 The KoiAir Aeration Kit comes with a 3 Year Limited Warranty This limited warranty is extended exclusively to the original purchaser and begins from the date of original purchase receipt Membrain sticks airline and diaphragms are considered wear items and are not covered by this warranty Abuse or misuse of this product voids all warranty Any sign of water damage inside the unit voids all warran
2. ATION SYSTEM Connect the weighted airline to the outlet on the compressor as well as to the diffuser Use a clamp at both ends and securely tighten using a flat head screwdriver or 3 8 socket nut driver Decide on a location for the KoiAir compressor It s important to elevate the compressor a few inches above ground level making sure the compressor is above the pond s water surface If power is not available at the pond s edge the compressor may be located at the power source and extra airline can be added up to 100 to reach your desired diffuser location NOTE It is recommended that the compressor be covered and not exposed directly to the elements This can be accomplished by purchasing a small TrueRock cover Item 510330 If you decide to use your own cover make sure it will keep water from coming in direct contact with the compressor and that there is plenty of ventilation Find a location in your water garden to place the dif 4 KoiAir 2 ONLY fuser If you have two diffusers distribute them equally Adjust control valves to balance throughout the water garden Do not exceed the max depth airflow between diffusers if desired rating when placing your diffusers Depths in excess of this It is not necessary to have even airflow rating will greatly reduce airflow to the diffuser and cause between diffusers nor will it have any excess strain on the compressor reducing its life expectancy effect on the life expectan
3. cy of the In case of extreme tempetaures hot or cold it is recom compressor mened to relocate plates from the deepest points of your pond
4. ns on an ice covered water garden will cause open water areas even in freezing conditions Also the ice thickness around these open areas will be much thinner than the ice over the remainder of the pond Injury or fatality may result from falling through the ice Airmax strongly recommends that this danger of thin ice around the diffuser site be clearly posted at frequent intervals Owner assumes all responsibility for operating KoiAir Aeration Kit during winter months If you choose to turn off your system for the winter do the following e Unplug the system and remove the diffuser s airline s and compressor e Store in a dry area protected from the elements such as a garage or basement climate control recommended GETTING TO KNOW YOUR KoiAir AERATION SYSTEM ia D oy IE r 7 i LSN one M DS KoiAir 2 shown above KoiAir 1 KoiAir 2 for ponds up to 8 000 gallons for ponds 8 000 16 000 gallons KA20 KA40 17 Watts 115 Volts 35 Watts 115 Volts Includes control valves N A to balance airflow between both diffusers Includes 25 of Includes 50 of weighted airline weighted airline 1 KoiAir Diffuser 2 KoiAir Diffusers 4 Max Depth 4 Max Depth O High Efficiency Compressor O Control Valves EasySet Weighted Airline KoiAir Weighted Diffuser O Hose Clamps 2 Hose Clamps 4 Hose Clamps INSTALLING YOUR KoiAir AER
5. ty For warranty claims product must be returned to the original place of purchase with original receipt Airmax Inc Safe Simple Solutions WWww airmaxeco com 014_13 Important Information Winter Operations Getting to Know Your KoiAir Aeration Kit a Installing Your KoiAir Aeration Kit 2 Maintenance Safety 2 Regular Maintenance 3 Warranty Information IMPORTANT INFORMATION e Never connect to an extension cord This may result in equipment failure e Do not allow anything to rest on the power cord e Do not place the unit where people may step on the power cord e Never override electrical or mechanical interlock devices e Never attempt maintenance functions that are not specified in the user manual Never operate the system if unusual noises or odors are detected Disconnect the power cord from the outlet and call for service A DANGER A e Read the operating instructions carefully e To reduce the risk of electric shock connect only to a properly grounded grounding type receptacle e THIS UNIT IS TO BE USED IN A CIRCUIT PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER e This unit has not been investigated for use in swimming pool areas e Disconnect unit from power source before handling e Repair and exchange of cable must be carried through by the supplier manufacturer WINTER OPERATION A DANGER A Operating in freezing conditio

Download Pdf Manuals

image

Related Search

Related Contents

ダウンロード  SKY-ー35 GR  237 ARTÍCULO CIENTÍFICO - UNIVERSIDAD POLITECNICA  Questions fréquemment posées  Reunion directeurs  ASOLITE CX-35G  Manuel d'utilisation  H-Series - Quality Certification Services  JVC KD-S641 User's Manual  CRS87-IT ( mi )  

Copyright © All rights reserved.
Failed to retrieve file