Home
FLEX Access Exam Table Operator`s Manual
Contents
1. Figure 7 Raise Seat off of Brace To aid in preventing injury or product damage please observe the following cautions when removing the table from the pallet NOTICE NOTICE Avoid Pelvic Tilt and Upholstery Damage Do not lift or move table by pulling up on the seat upholstery figure 8 Lifting by the seat will damage the pelvic tilt mechanism if equipped and may damage the upholstery Avoid Backrest Actuator and Upholstery Damage Never push forward on the backrest to move table Pushing on the backrest will cause backrest actuator damage and may cause upholstery damage figure 9 Figure 8 DO NOT Lift by Upholstery Figure 9 DO NOT Push on Backrest NOTICE Avoid Stirrup Damage Do not lift or move table by using the stirrups as a hand hold Lifting or moving table by stirrups can damage the internal DO NOT LIFT indexer housing unit Figure 10 BY STIRRUPS If Equipped Lifting Hazard The table weighs approximately 315 Ibs Use enough personnel to remove the table from the shipping pallet Use proper lifting techniques Failure to do so could Figure 10 DO NOT lift by Stirrups result in serious injury Printed in USA 2015 T Document 2102861 RevA Brewer Brewer PLEX Sam tabie INSTALLATION continued 12 Raise the backrest to its full up position Fi
2. 5700 5701 5800 5801 Slide out Leg Support Foot Controls Figure 1 Component Overview Printed in USA 2015 3 Document 2102861 RevA Brewer Brewer FLE ACCess Exam Table SPECIFICATIONS Weight of Table 0 ceecceeeeeeeeeeeeeeaeeees 315 Ibs Load Rating maximum e Seat Back 5700 5701 5800 5801 00 700 Ibs Leg SUDO I ise we seetnase entero ceeieeeceatereeeatesiaeaseeeeasen 50 Ibs e Pass Through Work Surface optional 15 Ibs e Grab Bars optional ccccccccsseeeeeeeeeeeeeeeees 100 Ibs Range of Motion e Back Section Range 0 horizontal to 75 85 e Table Top Height Range 18 0 5 in to 37 1 0 in e Pelvic Tilt Range Models 5701 amp 5801 Only 0 horizontal to 5 up Upholstery Dimensions e Upholstered Top 24 to 28 in wide x 60 in long e Upholstered Leg Support 18 in long x 18 in wide e Overall Length of Upholstery c 60 in long e Upholstery with Leg Support Extended 78 in long Electrical Rating e 5700 5800 115 VAC nominal 60 HZ 6 0 amps e 5701 5801 W Outlet 115 VAC nominal 60 HZ 6 0 amps e Fuse Rating e Control Box Fuse Ratiing cccsseeeeeeeeees 250V 2 5A e Option Warmer amp Outlet Fuse Rating 250V 3 0A e Outlet Max Load cccccccseccceecceeeeeeeeeeeeeeeeeeeseeees 2 0A Duty Cycle 10
3. Adjusting the Rear Base Extension i a oerens After leveling the table the Rear Base Extension should be brought into contact with the floor Figure 16 1 Loosen the two Rear Base Extension adjusting screws 2 Lower plate until it contacts the floor Rear Base Support Plate 3 Tighten the two Rear Base Extension adjusting screws Figure 16 Adjusting the Rear Base Extension Printed in USA 2015 9 Document 2102861 RevA Brewer Brewer Installing the Power Cord di 2 Installing the Foot Control 1 Zs Installing Grab Bars Optional 1 FLE ACCess Exam Table INSTALLATION continued Remove the power cord from the front drawer Insert the female plug end of the power cord into the receptacle on the table Figure 17 Make Power Cord Foot Control sure the plug is fully seated Receptacle Remove the foot control from the front drawer Insert the male plug of the foot control cord into the receptacle on the table Figure 17 Make sure the plug is fully seated See Figure 6 for proper insertion of the foot control plug Failure to properly insert the foot control plug can cause Figure 17 Foot Control and Power Cord Receptacles some functions to not operate properly Remove grab bars from the carton banded to the pallet Grab Bar Grab bars are interchangeable and may be installed on either side Align pin on grab bar shaft with mating slot on side of table See Fi
4. P EEEE 2 minutes on 18 minutes off motor run time NOTICE Certifications This product has been evaluated with respect to electrical shock fire and mechanical hazards only in accordance with UL60601 1 CAN CSA C22 2 No 601 1 Model Configurations Power Cord e Length eee eee Extends 70 in from Table WG E E E E E ET A Detachable e CONGUCIONS in tiaresssaramnnnstusiernitedernne 18 AWG 3 Conductor OO ec eee ee A Hospital Grade Plug Type of protection against electrical shock e Model 5700 and 5800 Class 2 Double Insulated e Models 5701 and 5801 Class 1 Grounded e Patient applied parts all Models seesee essees Type B Type of protection against ingress of water Ordinary Paper Roll Sizes sail 16 6 2 eae ee ee ee Pere meee 18 in x 3 5 in 9 MONA arora A N E E ane eece 21 in x 3 5 in Certifications UL60601 1 CAN CSA C22 2 No 601 1 Operating Conditions e Temperature Range cccssccseseceseesseeees 65 to 85 F e Relative Humidity cccccceeeesseeeeeeeeeeens 10 to 90 Transportation and Storage e emperature cccccccccceccceeeeeeeeseeeeeeeees 20 F to 150 F el e E er 10 to 90 elie T o Classified in the United States and Canada per cM us the standards listed above NOTICE Electromagnetic Interference EMI This product is designed and built to minimize electromagnetic interference with other de
5. 2102894 5715 XX 100253 102031 Use Restrictions Covers hole created when user chooses to remove grab bars Plastic pan for disposing of debris during procedures located beneath leg support pad Stainless steel pan for disposing of debris during procedures located beneath leg support pad Replacement for a single pedal foot control Replacement for a 2 pedal foot control with return to chair feature only 3A drawer warmer outlet fuse qty 1 Contains two Replacement Grab Bars Used on tables currently having grab bars Replacement Knee Crutch Adapters on tables currently having adapters installed Replacement pull out metal support with slides and hardware Hardware kit for leg support Contains screws magnet tension springs etcetera Replacement upholstered leg support pad Contains Work Surface and hardware Provides surface for laptop paper work blood draw items etc Contains the black components screws and springs through which the stirrup beam passes Contains two Stirrups and hardware for replacing Stirrups on tables with outlets not currently having stirrups Contains two Stirrups and hardware for adding Stirrups to tables without outlets not currently having stirrups Replacement top with hardware for the 5700 5701 5800 and 5801 examination tables in 15 standard colors Includes upholstered foot pad Conveniently and safely disposes of and captures fluids during urology proc
6. Powered Backrest Models 5800 amp 5801 1 To lower the seat back depress and hold the Back Down pedal until the desired angle is achieved then release the pedal 2 To raise the seat back depress and hold the Back Up pedal until the desired angle is achieved then release the pedal Printed in USA 2015 18 Document 2102861 RevA Brewer Brewer Gee TABLE ADJUSTMENTS continued Manual Pelvic Tilt Models 5701 and 5801 The manual pelvic tilt feature sets the seat angle at 0 horizontal or 5 up position Pelvic Tilt Adjustment Bar Pull up on the front of the seat and the pelvic tilt automatically travels to the locked tilt position Figure 38 NOTICE Engaging the Pelvic Tilt Mechanism Pulling up with excessive force can damage the pelvic tilt mechanism Lift only with enough force to engage mechanism NOTICE Lowering the Pelvic Tilt Mechanism To lower seat lift the adjustment lever and lower the seat to the horizontal position Patient must be removed from table prior to lowering the pelvic tilt mechanism Front Drawer Warmer Models 5701 and 5801 Models 5701 and 5801 are equipped with a drawer warmer that is turned on by a switch located above the drawer Figure 39 NOTICE Drawer Warmer Models 5701 and 5801 Outlet Models 5701 and 5801 Proper Loading of the Front Drawer Do not stack instruments in the front drawer Place instruments in one layer in
7. the bottom of the drawer Outlet Models 5701 and 5801 Models 5701 and 5801 are equipped with an Outlet Figure 40 The maximum total load that can be plugged into the outlet is 2 amps NOTICE Maximum Outlet Rating Plugging a device into the outlet on the side of the table with rating higher than 2 amps may cause the fuse at the back of the table to blow Figure 40 Table Outlet Printed in USA 2015 19 Document 2102861 RevA Brewer Brewer FLEX SS o MAINTENANCE Preventative Maintenance Table Care For the latest in Cleaning Guidelines visit www brewercompany com NOTICE More Cleaning Instructions Available Inspect table every 6 months For the latest in Cleaning Guidelines visit e Periodically inspect the electrical and foot control www brewercompany com cords to ensure they are free of cuts or damage Loose Fasteners and Damaged Components Hazard Failure to perform periodic inspections of the table could result in personal injury or equipment damage e Inspect the mechanical functions to ensure satisfac tory operation e Check fasteners to make sure they are present and tightened securely e Lubricate the backrest hinge with a food grade silicon lubricant Figure 41 Cover surrounding area with cloth to protect from overspray and wipe excess Figure 41 Pelvic Tilt Adjustment SERVICE Drawer Warmer Fuse Replacement Models 5701 and 5801 1 Disconnect power cord Shoc
8. A Brewer Brewer FLEX ie OPERATION continued Foot Pad The foot pad can be slid beneath the seat with the leg support extended for easy access to the treatment pan Figure 25 Pushing the leg support back in will allow the glides on the foot pad to drop into slots The foot pad will once again come out with the leg support the next time it is pulled out Treatment Pan A removable treatment pan is built in underneath the leg support pad for use during examination Pull the leg support fully out and remove the leg support pad or slide it back under the seat Figure 26 to access the pan Figure 26 Remove the treatment pan for cleaning Front Drawer A storage drawer for supplies is located at the front of the table Models 5701 and 5801 are equipped with a drawer warmer that is turned on by a switch located above the drawer Figure 27 Printed in USA 2015 Treatment Pan Leg Support xd ee Front Drawer Drawer Warmer On Off Switch Models 5701 amp 5801 only Figure 27 Drawer Warmer Switch and Front Drawer 14 Document 2102861 RevA Pass Through Work Surface Optional A Brewer Brewer 1a Geen OPERATION continued Paper Roll Holder To change a paper roll remove old paper roll tube place the paper holder rod into the paper roll tube and place into paper roll holder J Hooks located on the rear of the seat back Figure 28 Pull the end of the roll over the
9. Brewer FLEX Table Installation amp Operation Manual Important Information Safety Information Table Adjustments Maintenance Component Identification Specifications Installation Operation Printed in USA 2015 Options and Accessories Common Service Parts The Brewer Company LLC N88 W13901 Main Street Suite 100 Menomonee Falls WI 53051 P 1 888 Brewer F 262 251 2332 www brewercompany com Document 2102861 RevA Brewer Brewer FLE ACcCess Exam Table IMPORTANT INFORMATION General Read and understand all operating instructions safety information and maintenance requirements contained in this manual prior to operating the table Become familiar with all of the table functions before using it with a patient The Brewer Flex Access Exam Table Models 5700 and 5800 Series are designed to provide positioning and support of patients during general examinations conducted by qualified medical professionals The Brewer Flex Access Exam Table is primarily used in examination rooms for general examinations and minor procedures The wide variety of positions provided by one or two powered motions and slide out leg support create a safe and convenient patient positioning table for use in the doctor s office The table is easily adjusted to a wide variety of positions using the convenient foot control provided with the table The table height can be adjusted from 18 to 37 The table seatin
10. able Failure to do so could result in unwanted motion injury and possible damage to the table Printed in USA 2015 NOTICE Optimum Table Performance For optimum table performance allow the table to reach room temperature before operating NOTICE Avoid Continuous Operation The table s control system includes a thermal overload safety switch to protect from overheating If the table is operated continuously causing the control to exceed its allowable operating temperature the thermal overload safety switch will shut off If normal operation ceases do not attempt to operate the table Allow the table to cool for 10 15 minutes before attempting to use again The thermal overload switch will automatically reset when it has reached a safe operating temperature NOTICE Fuse Protected The control system is protected by a fuse to prevent excessive current draw which could damage the system If operation does not resume after a cooling period of one hour contact Brewer 800 558 8777 NOTICE Actuator Travel Limit Protection Each control function will automatically stop moving when either the UP or DOWN travel limit is reached If the foot pedal is pressed with travel at its limit the actuator will not operate Sensors prevent the actuator motor from operating when travel limit has been reached preventing wear of the actuator NOTICE Proper Power Supply Do not use any power supply other than that listed on the rating la
11. bel Failure to do so may result in equipment damage NOTICE Avoid Foot Control Damage The foot control is moisture resistant and runs on low voltage eliminating shock hazards However to avoid temporary or permanent damage to the foot control do not immerse in water or liquids 11 Document 2102861 RevA Brewer Brewer FLEX Goeecere OPERATION continued BACK UP GREEN LIGHT Raises the back Lights when power to the foot control is ON RETURN TO CHAIR BUTTON STOP BUTTON RED BLUE Stops all functions Returns table to chair when pressed ees T position when pressed RETURN TO CHAIR V V TABLE UP Brewer Raises the seat upward TABLE UP TABLE DOWN BACK DOWN TABLE DOWN Raises the Lowers the seat Lowers the back Lowers the seat upward downward seat downward MODELS 5700 amp 5701 MODELS 5800 amp 5801 Figure 21 Foot Controls Models 5700 amp 5701 Models 5700 and 5701 are equipped with a single pedal foot control that controls the raising and lowering of the seat Models 5800 amp 5801 Models 5800 and 5801 are equipped with a dual pedal foot control that controls the raising and lowering of the seat and the raising and lowering of the seat back In addition the foot control features the following Return to Chair When pressed the table automatically returns to the low chair position The seat back will rise to the full up position and the table
12. brackets from levelers once bolts are removed Remove the 2 screws attaching the spacers on either side of the wooden U shaped brace located under the front corners of the cabinet Figure 3 Remove the 2 screws attaching the U shaped brace to the pallet Figure 3 Printed in USA 2015 NOTICE Proper Handling To avoid injury and damage to the table handle only as indicated in Figures 2 through 16 Do not handle as shown in Figures 8 through 10 NOTICE Avoid Self Activation Damage Plugging table into receptacle prior to the removal of all packaging materials may cause damage if self activation occurs D Figure 2 Remove Shipping Brackets Figure 3 Remove Spacer and U Brace Screws NOTICE Grab Bar Option If your table was purchased with the Grab Bar option remove the box from the back of the pallet Document 2102861 RevA Brewer Brewer FLEX SS o INSTALLATION continued NOTICE In order to prepare the table for moving you must power it up and change the position from the position 4 Cut the shipping strap and discard strap and foam tube Figure 4 5 Make sure all shipping materials except for wooden brace and spacers and packing foam are removed from the table pallet and surrounding area 6 Remove the foot control and power cor
13. d from the _ front drawer after packing materials have been Figure 4 Cut Shipping Strap removed 7 Insert the foot control cord into the receptacle at the bottom of the rear panel Figure 5 Note Power Cord Foot Control Make sure the tab on the plug is aligned with the Inlet Receptacle slot in the receptacle The plug may appear to be fully inserted and yet have some distance to go Wiggle the foot control plug while pushing it in firmly to ensure that it is fully seated Figure 6 8 Remove the gray power cord from the front drawer S NOTICE ae S j Confirm Voltage and Plug Type See Qla 31g yie RE table for electrical rating of this unit The three pronged grounding plug on the table power cord must be plugged into a matching three pronged grounded non isolated correctly polarized 115 VAC receptacle Foot Control Plug Even with or Above Receptacle Rim 9 Plug the power cord into the receptacle at the bottom of the rear panel Figure 5 Plug the power cord into a 115 Volt grounded receptacle Foot Control Plug not Fully Inserted Foot Control Plug Below Receptacle Rim aqno Foot Control Plug Fully Inserted Figure 6 Foot Control Properly Pugged In Printed in USA 2015 6 Document 2102861 RevA Brewer Brewer TLLA k INSTALLATION continued 11 Press lift up on the foot control to raise the seat approximately 1 Figure 7
14. edures For mounting of Welch Allyn IV light Light not included Factory Installed means that the table came from the factory with this option or accessory already built in Order this service part or kit to replace this component or hardware Printed in USA 2015 Document 2102861 RevA
15. erial Number Model Number Authorized Dealer Name Dealer Phone Number Dealer Address 2 Document 2102861 RevA Brewer FLEA ae SAFETY INFORMATION Safety Information Sa l This is the safety alert symbol It is used to The primary concern of The Brewer Company is a 7 alert you to potential physical injury hazards Brewer that the equipment is operated and maintained with the safety of the patient and healthcare staff nea i peered Teena aes an in mind To ensure safe and reliable operation a a a e Read and understand all instructions in this DANGER Indicates a hazardous manual before attempting to install or operate A DANGER situation that if not avoided will the unit result in death or serious injury Ensure that appropriate personnel are WARNING indicates a hazardous informed on the manual contents This is the situation which if not avoided could responsibility of the purchaser result in death or serious injury CAUTION indicates a hazardous situation which if not avoided could result in minor or moderate injury Ensure that this manual is located near the table or if possible permanently affixed to the table COMPONENT IDENTIFICATION Paper Roll Holder Back Release Handle Models 5700 5701 T O Pelvic Tilt Bar Models 5701 5801 only 2 Drawer Warmer Switch Models 5701 5801 only Z Front Drawer Treatment Pan SafeGlide located under Leg Support Pad
16. g surface on models 5701 and 5801 can be moved from the normal horizontal position to an angle of 5 The backrest can be adjusted from a flat lying down position to an 80 angle for seating In addition to the electronically controlled positions noted above several manual adjustments are available Standard Features e The SafeGlide leg support can be extended up to 21 for the patient prone position e Aremovable treatment pan is built in underneath the leg support pad for use during examinations e Astorage drawer at the front of the table may be used for supplies Optional Features e Stirrups may be manually extended through infinite positions and four lateral positions e Grab bars attached to each side of the table may be rotated out of position or removed for improved ac cess to the patient e Pass through work surface stored under the seat may be pulled out from either side of the table Printed in USA 2015 Service If you require assistance with the installation or operation of your Brewer table call the Brewer Customer Service Department at 1 888 Brewer1 Our trained staff will attempt to assist you in correcting the problem directly over the phone If service is required a factory authorized technician will be sent to your location Please fill in the following information for use when calling the Brewer Company or your distributor with questions regarding your unit Date of Purchase S
17. gure 11 Figure 11 Raise Backrest 13 Unplug foot control and power cord and place into front storage drawer Figure 12 14 Tilt table slightly to place the 4 slides under levelers Figure 13 Figure 13 Installing Leveler Slides Printed in USA 2015 8 Document 2102861 RevA Brewer Brewer FLEXA o ik INSTALLATION continued 15 Slide table partially off of pallet and stop when there is sufficient room to place furniture dolly beneath base of table Finish pulling table onto furniture dolly Figure 14 Leveling the Table Figure 14 Slide table off of pallet A leveling screw pad Figure 15 is located in four places under the table s base Adjust the four leveling pads to achieve a solid level installation NOTICE Prevent Leveler Damage Levelers must remain in the table and be fully engaged a minimum or 3 turns If levelers are not fully engaged in the base damage to the threading in the base and or leveler can occur Turn out or in to level NOTICE View of underside of base Prevent Floor Damage and Unwanted Table Movement Figure 15 Leveling Screw Pad located under table Make sure the rubber caps are present on all 4 levelers Missing caps can allow the table to slide and the exposed metal portion of the leveler can damage flooring Rear Base Extension
18. gure 18 Push grab bar all the way down and rotate to front of table Push grab bar down until it engages to prevent left Mounting Support or right movement Figure 18 Grab Bar Printed in USA 2015 10 Document 2102861 RevA Brewer Brewer TLIA k OPERATION Explosion Fire Hazard Do not use this table in an explosive or oxy gen rich atmosphere Failure to do so may result in serious personal injury or death Table Malfunction Hazard If table malfunctions immediately remove your foot from the controls unplug the power cord from the receptacle and assist the patient from the table Service the table prior to use Continuing to use a malfunctioning table may result in patient or personal injury or product damage Area Not Clear Hazard Before initiating power keep personnel and equipment clear of table before initiating movement to avoid personal injury or damage to the equipment Shock Hazard When performing cauterization or similar treatment the patient must be insulated from the metal portions of the table by non con ductive material Failure to do so may result in electrical shock Explosion Fire Hazard Do not use this table in an explosive or oxygen rich atmosphere Failure to do so may result in serious personal injury or death Unintended Operation Keep foreign objects away from foot control To avoid accidental operation be sure the foot control is NOT positioned below the front of the t
19. is 250V 2 5AT for 115 VAC F o Figure 45 6 Reassemble Figure 44 igure 45 eme Two Screw Remove Shroud Fuse Cover Control Box Fuse Replacement for tables with the seat in the down position Control Box Shock Hazard Disconnect power by removing plug from the power outlet before changing fuses 1 Remove the 2 screws that secure the rear cover Figure 46 2 Remove the rear cover by tipping the top of the shroud away from the table and lifting up 3 Swing the cover to the right using caution to not pull on the cabling 4 Apply upward pressure on the control box while unscrewing the control box securing screw Figure 47 5 Push inner shroud forward Figure 48 while sliding the control box off of the actuator Figure 49 6 See steps 3 amp 4 of the above set of instructions for control box fuse replacement 7 Replace fuses using spare fuses in fuse cover Fuse type is 250V 2 5AT for 115 VAC 8 Reassemble NOTE The control box and actuator have mating slots Be sure that the slots slide together to engage control box with actuator Figure 48 Figure 49 Printed in USA 2015 21 Document 2102861 RevA Brewer Brewer F LE ira iE Listed below are the options and accessories which are authorized for use with this table Description Order No Use Restrictions Armrest Hole Cap 101872 e hole created when user chooses to remove grab Debris Pan Stainless Steel Stainless s
20. k Hazard Disconnect power by removing plug from the wall receptacle before changing fuses 2 Remove fuse cap from back of table near the power cord Figure 42 a Insert flat bladed screwdriver into slot b Push in and turn counterclockwise 1 4 turn c Pull cap fuse from holder Fuse Cap 3 Replace fuse Fuse type is 5 x 20mm 250V 3 0A a Insert replacement fuse in cap b Insert cap fuse into holder c Push and twist 1 4 turn clockwise with screwdriver to lock 4 Connect power cord and check drawer warmer for proper operation Figure 42 Printed in USA 2015 20 Document 2102861 RevA Brewer Brewer FLEA ae Control Box Fuse Replacement for tables with the seat in the up position Shock Hazard Disconnect power by removing plug from the power outlet before changing fuses 1 Manually raise table and prop in raised position _CRUSH HAZARD using a support device intended for this purpose Failure to support seat See Figure 43 NOTE Your support device may vary section during service from example could result in death or severe injury 2 Remove shroud below seat to expose actuators and my control box See Figure 44 3 Locate fuse cover on control box See Figure 45 4 Pull out fuse cover with pliers NOTICE Prevent Fuse Cover Damage Pull fuse cover straight out DO NOT TWIST 5 Replace fuses using spare fuses in fuse cover Fuse T type
21. light to side of table Field Installed Light not included Work Surface Pass Through 2102896 Work surface that stows beneath seat upholstery passes Field Installed to either side providing a surface for lab paper work etc Field Installed means that the table did not come from the factory with this feature built in Order this option or accessory to add it to the table you currently have Printed in USA 2015 22 Document 2102861 RevA Brewer Brewer TLIA COMMON SERVICE PARTS Listed below are the common service parts and kits which are authorized for use with this table Description Armrest Hole Cap Debris Pan Plastic Treatment Pan Debris Pan Stainless Steel Treatment Pan Foot Control Single pedal for manual back models 5700 and 5701 Foot Control Two pedal with Return To Chair feature 5800 amp 5801 Fuse 3A Grab Bar Kit Factory Installed Knee Crutch Adapters Factory installed Leg Support Leg Support Hardware Leg Support Pad Pass Through Work Surface Factory Installed Stirrup Indexer Kit Stirrup Kit with Outlet Factory Installed Stirrup Kit without Outlet Factory Installed Upholstery Replacement Urology Tray w Hose amp Bucket Welch Allyn IV Light Bracket Factory Installed Order No 101872 2102836 2102848 2102858 2102490 2102891 100540 2102774 2102775 2102776 2102892 2102270 2102893
22. nued Seat Back The back can be adjusted to any angle between horizontal and 80 F MINIMUM HEIGHT 28 For lowering backrest to horizontal position Backrest Lowering Hazard Depressing the manual backrest release handle while a patient is seated on the table can cause the backrest to lower rapidly Lower the backrest in increments by depressing and releasing the handle Allowing the backrest to lower in a single motion could cause injury to the patient NOTICE To Lower Backrest Fully Table must be raised to a height of 28 before the backrest can be lowered to the horizontal position See Figure 37 Pneumatic Manual Backrest Models 5700 amp 5701 1 To lower the seat back push down on the seat back while pulling the release handle upward MODELS 2 To raise the seat back place hand on the backrest to 5700 amp 5701 5800 amp 5801 prevent it from rising rapidly while pulling the release handle upward The seat back will lock in the desired position when the handle is released Figure 37 Adjusting Seat Back NOTICE Power Back Actuator Push Only On power back models the back is positioned by a push only actuator that raises the back When lowered the actuator retracts and gravity causes the back to lower
23. ontinued Grab Bars Optional In the forward normal use position the grab bars lock into place preventing left or right rotation Pull up to rotate The grab bars can be rotated to the side of the table for Push down to improved access to the patient Pull up on the grab bar lock in place and rotate to the desired position The grab bar locks in the front and rear position Figure 34 The grab bar can be removed from the table by pulling up on the grab bar rotating it to the 90 position and then lifting it out of its holder Figure 34 Grab Bar Adjustment TABLE ADJUSTMENTS Table Height The table can be adjusted to any height between 18 to 37 Figure 36 1 To raise the table depress and hold the Table Up pedal until the desired height is achieved then release the pedal 2 To lower the table raise the backrest to the upright position then depress and hold the Table Down pedal until the desired height is achieved then release the pedal or press the Return to Chair button Figure 35 MODELS MODELS 5700 amp 5701 5800 amp 5801 Return to Chair button MODELS 5800 amp 5801 MODELS 5700 amp 5701 Figure 35 Lowering with Return to Chair Figure 36 Table Height Positioning Printed in USA 2015 17 Document 2102861 RevA Brewer Brewer PLEX Bam table TABLE ADJUSTMENTS conti
24. riction locking mechanism 2 Unfold stirrup upward to the fully open position 3 Adjust the stirrup to the desired length by sliding it in or out Locking Mechanism Stirrup Lateral Adjustment 1 Lift end of stirrup slightly and then rotate outward to ae desired position 2 When the desired position is achieved lower the stirrup to engage the lateral locking mechanism Figures 31 and 32 3 Check that lateral locking mechanism is engaged by attempting to move stirrup assembly side to side without lifting on the stirrup end Storing the Stirrup Fall Hazard Figure 31 Stirrups Failure to engage the lateral lock ing mechanism could allow patient to lose balance resulting in personal injury to patient Figures 31 and 32 Close Up of Locking Mechanism Figure 32 Stirrup Locking Mechanism Storing the Stirrups Figure 33 Affix No Attachments NOTICE Use Stirrup Only as Designed 1 To store the stirrups in the table grasp end of stirrup Do not use any part of the stirrup for attachment of any and pull straight out to its full extension device Figure 33 Warranty will be voided If knee crutches 2 Fold stirrup down against bar then rotate it to the are required for use order mounting adapters and clamps inner most lateral position and slide it back into the shown on last page stowed position Printed in USA 2015 16 Document 2102861 RevA Brewer Brewer FLEXA o ike OPERATION c
25. teel pan for disposing of debris during 98464 Treatment Pan procedures located beneath leg support pad Drawer Organizer Front 100407 Front drawer dividers for separation and organization Contains two grab bars decorative side shrouds and sockets for tables not currently having grab bars To replace existing grab bars see COMMON SERVICE PARTS All three items below are required for knee crutch use Purchase any item listed that is not currently on your table Knee Crutches Deluxe Articulating 99504 Grab Bar Kit Field Installed 2102895 Allows leg positioning for comfort and ease of examination cies g SEADE E 100550 Provides attachment point for Knee Crutch Clamps Knee Crutch Clamp 99502 To hold deluxe articulating knee crutches 1 clamp only Pass Through Work Surface Field Installed Stirrup Kit no Outlet Field Installed 2102898 Stirrup Kit with Outlet Field Installed 2102897 Contains Work Surface and hardware Provides surface for 2102896 laptop paper work blood draw items etc Contains two Stirrups and hardware for adding Stirrups to tables without outlets and not currently having stirrups Contains two Stirrups and hardware for adding Stirrups to tables with outlets and not currently having stirrups Urology Tray w Hose amp Bucket 100253 Conveniently and safely disposes of and captures fluids during urology procedures Welch Allyn IV Light Bracket 102032 For mounting of Welch Allyn IV
26. top of the seat back and place in the desired position Uses Paper Rolls 18 by 3 5 or 21 by 3 5 Figure 28 Paper Roll Installation pass through work surface stored under the seat Figure 29 may be pulled out from either side of Work Surface the table Grasp the edge of the work surface and pull until it is fully extended Push it fully in to stow after use Removing the Work Surface for Cleaning 1 2 3 4 Fall Hazard The work surface is rated for 15 Ibs and is not intended for use as a seat Sitting on work surface could cause it to bend or break or cause the table to tip creating a fall hazard leading to injury Figure 29 Pass Through Work Surface Push work surface in to reveal a white plastic stop screw Remove the white plastic screw Figure 30 Pull the work surface toward you and remove it Reinsert screw after replacing work surface Plastic Screw Figure 30 Location of White Plastic Stop Screw Printed in USA 2015 15 Document 2102861 RevA Brewer Brewer Pi Xo we OPERATION continued Adjustable Stirrups Optional Operating the Stirrups Figure 31 1 To operate the stirrups grasp end of stirrup and pull straight out of the table Lift up slightly while sliding the stirrup out NOTE Applying downward pressure when pulling stirrup from table may make it difficult to move Resistance PUAS ARTAR NE is normal and is part of the stirrup f
27. vices however if interference is noticed between another device and this product remove the interfering device from the room or plug this product into an isolated circuit Power Back Pneumatic Pelvic Tilt Drawer Return To Manual Back reo i x a a a 1 3 a sso XP S G S X S Printed in USA 2015 Document 2102861 RevA Brewer Brewer FLE ACCess Exam Table INSTALLATION NOTICE Inspect Carton and Contents Inspect all boxes and contents for damage Report any damage to the carrier immediately NOTICE No Sharp Tools To avoid damaging the table s upholstery or painted surfaces DO NOT use a knife or other sharp object to open the packaging Overview Perform the following sequence in order when setting up the table Uncrating the table Leveling the table Adjusting Rear Base Extension Installing Power Cord Installing Foot Control Installing Grab Bars Tools Required Drill Driver 7 16 socket bit or 7 16 wrench 9 16 wrench 2 Phillips bit side cutter and furniture dolly Uncrating 1 2 Remove stretch wrap surrounding table Remove the 4 steel shipping brackets securing the table to the pallet Figure 2 The brackets hook onto the table levelers to hold the table securely to the pallet Remove the 2 bolts from each bracket using a 7 16 socket or wrench Take care not to scratch the unit when using the driver or turning the wrench Remove
28. wering the seat e Models 5700 amp 5701 Raise the backrest manually to clear the switch When clear of the switch continue lowering the seat e Models 5800 amp 5801 Depress the BACK UP pedal Figure 21 to clear the switch When clear of the switch continue lowering the seat SafeGlide Leg Support The leg support is located under the seat cushion Figure 23 It can be extended 19 for the patient prone position Pull leg support out to the fully extended position To return the leg support to its stored position simply push the leg extension in Fall Hazard The leg support is rated for 50 Ibs and is not intended for use as a seat Sitting on leg support could cause it to retract bend or cause the table to tip forward creating a fall hazard leading to serious injury The SafeGlide Leg Support comes with the leg support adjusted for the least amount of resistance If you find it to glide too freely the resistance can be increased by turning the thumbscrews Figure 24 inward Turn both thumbscrews the same number of turns inward or outward until the desired resistance is obtained Printed in USA 2015 Safety Switch Located on the Top Shroud Safety Switches Located Inside Seat Back both sides Safety Switches Located on Seat Bottom Plate Figure 22 Seat and Backrest Safety Switches Figure 24 Leg Support Tension Adjustment 13 Document 2102861 Rev
29. will lower to the full down position and stop If the Emergency Stop or either pedal is pressed while the table is in motion the system will return to manual mode and all motion will stop Stop When pressed stops the Return to Chair function Green Light 2 pedal foot controls only indicates that there is power to the foot control NOTICE Unattended Return to Chair Operation Remain with and observe patient during Return to Chair operation Return to Chair feature may need to be momentarily interrupted for patient to readjust him or herself or for hazards to be removed before resuming motion Press the Return to Chair button to resume motion only when patient has situated him or herself or hazards have been removed Printed in USA 2015 12 Document 2102861 RevA Brewer Brewer FLEA co ike OPERATION continued Seat and Backrest Safety Switches Seat Switch All models are equipped with switches on the seat bottom Figure 22 which automatically stops the lowering function of the seat if any of the switches comes into contact with an object as the seat is lowering To continue lowering the seat press up on the TABLE UP pedal Figure 21 clear the obstruction and continue lowering the seat Backrest Switch All models are equipped with a switch on the top shroud Figure 22 which automatically stops the lowering function of the seat and back if the switch is contacted by the backrest To continue lo