Home

Motif Fresco User Manual

image

Contents

1. architectural f by blizzard lighting IR remote DMX512 equipped Q IP65 rated TABLE OF CONTENTS Motif Fresco 1 1 Getting Started 3 What s In The Box 3 Getting It Out Of The Box 3 Optional Accessories 3 Powering Up 3 Getting A Hold Of Us 3 Safety Instructions Don t Stick Your Hand In The Toaster 4 2 Meet The Motif Fresco 5 Features 5 DMX Quick Reference 5 The Motif Fresco Pin up Picture 6 3 Setup 7 Fuse Replacement 7 Connecting A Bunch Of Motif Fresco s 7 Data DMX Cables Wi Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 4 Operating Adjustments 10 The Control Panel 10 Control Panel Menu Structure T1 DMX Mode 11 Slave Mode 11 Static Colors 12 Built In Programs 12 Auto Mode 12 Manual Color Adjustments 12 Restore Factory Settings 12 Using the Remote Control 13 DMX Values In Depth 15 5 Appendix 16 A Quick DMX Lesson 16 Troubleshooting 16 Keeping Your Motif Fresco As Good As New 17 Returns Gasp 18 Shipping Issues 18 Tech Specs 19 Page 2 Motif Fresco Manual Rev A Copyright c 2014 Blizzard Lighting LLC 1 GETTING STARTED What s In The Box e 1 x Motif Fresco LED Fixture e 1 x IP Rated AC Power Cord with Cable Cap e This Lovely User Manual Optional Accessories sold separately The following accessories are available for this fixture But being the lone wolves that the
2. That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service But like any complex piece of equipment designed and built by humans once in a while something doesn t go as planned If you find yourself with a fixture that isn t behaving like a good little fixture should you ll need to obtain a Return Authori zation RA Don t worry this is easy Just send an email to support blizzardlighting com and we ll issue you an RA Then you ll need to send the unit to us using a trackable pre paid freight method We suggest using USPS Priority or UPS Make sure you carefully pack the fixture for transit and whenever possible use the original box amp packing for shipping When returning your fixture for service be sure to include the following 1 Your contact information Name Address Phone Number Email address 2 The RA issued to you 3 A brief description of the problem symptoms We will at our discretion repair or replace the fixture Please remember that any shipping damage which occurs in transit to us is the customer s responsibil ity so pack it well Shipping Issues Damage incurred in shipping is the responsibility of the shipper and must be reported to the carrier immediately upon receipt of the items Claims must be made within seven 7 days of receipt Pa
3. d512 then hit lt SETUP gt again to confirm your choice 2 You can now use the lt UP DOWN gt buttons to scroll through your choices of 3 ch 5 ch or 7ch Press lt MODE gt to confirm your choice Slave Mode 1 To use as a slave unit simply use the lt MODE gt button to scroll to SLAu This fixture will now be in slave mode and follow the master unit which is the fixture in the DMX chain Page 1 Motif Fresco Manual Rev A Copyright c 2014 Blizzard Lighting LLC Static Colors 1 To use any of the built in static colors use the lt MODE gt button to scroll to Pr 01 and hit lt SETUP gt Use the lt UP DOWN gt buttons to scroll through the static color choices Push the lt SETUP gt button to confirm your choice 2 Now you can adjust the strobe speed by selecting the strobe speed adjustment set tings of FSOO FS99 slow lt gt fast Built in Programs 1 To set the fixture to run a single built in program use the lt MODE gt button to scroll to Pr and press the lt SETUP gt button Then use the lt UP DOWN gt buttons to scroll through the built in program choices of PrO2 Pr07 and push the lt SETUP gt button 2 Now you can adjust the speed of the program by using the lt UP DOWN gt buttons and choose from SPO1 SPFL slow lt gt fast and push the lt SETUP gt button To conclude setup you now have the option to adjust the strobe speed of the program by selecting the strobe adjustment
4. normal conditions Check the fixture or device carefully to make sure that if a voltage selection switch exists that it is set to the correct line voltage you will use Warning Verify that the voltage select switch on your unit matches the line voltage applied Damage to your fixture may result if the line voltage applied does not match the voltage indicated on the voltage selector switch All fixtures must be connected to circuits with a suitable Ground Earthing Getting A Hold Of Us If something is wrong just give us a call or send an email We ll be happy to help honest Blizzard Lighting N16 W23390 Stoneridge Dr Ste E Waukesha WI 53188 USA www blizzardlighting com 414 395 8365 Email support blizzardlighting com Disclaimer The information and specifications contained in this document are subject to change without notice Blizzard Lighting assumes no responsibility or liability for any errors or omissions that may appear in this user manual Blizzard Lighting reserves the right to update the existing document or to create a new document to correct any errors or omissions at any time You can download the latest version of this document from www blizzardlighting com Last Edited Page 3 Motif Fresco Manual Rev A Copyright c 2014 Blizzard Lighting LLC SAFETY INSTRUCTIONS Please read these instructions carefully They include important information about the installation usage and maintenance of
5. Copyright c 2014 Blizzard Lighting LLC Figure 1 The Motif Fresco Pin Up Picture DMX Out AC Power TRI Color RGB LEDs Out AC Power In Figure 2 The Remote Control sold separately R G B Dimming Buttons Blackout Auto Run Select Program a DMX Mode Speed SA is not available for this Slave Mode ee Set Address Buttons 0 9 Buttons Page 6 Motif Fresco Manual Rev A Copyright c 2014 Blizzard Lighting LLC 3 SETUP Before replacing a fuse disconnect power cord ALWAYS replace with the same type and rating of fuse Connecting A Bunch of Motif Fresco Fixtures You will need a serial data link to run light shows using a DMX 512 controller or to run shows on two or more fixtures set to sync in master slave operating mode The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support Fixtures on a serial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data link is 32 fixtures Data DMX Cabling To get a DMX signal into or out to standard 3 pin DMX cable a Blizzard DMX adapter cable set CABLE Motif DMX S
6. ET must be used to convert the standard DMX plug to mini DMX plug or vice versa And when linking between any Motif Series units a 3 meter mini DMX extension is available if nessecary for your application CABLE Motif Data3M Both of these items are sold separately Please contact your authorized Blizzard Lighting dealer to order either of these items All of your data cables should be a high grade cable that can carry a strong signal making them less prone to electromagnetic interference For instance Belden 9841 meets the specifications for EIA RS 485 applications Standard microphone cables will probably be OK but note that they cannot transmit DMX data as reliably over long distances In any event the cable should have the following characteristics 2 conductor twisted pair plus a shield Maximum capacitance between conductors 30 pF ft Maximum capacitance between conductor amp shield 55 pF ft Maximum resistance of 20 ohms 1000 ft Nominal impedance 100 140 ohms Page 7 Motif Fresco Manual Rev A Copyright c 2014 Blizzard Lighting LLC Cable Connectors Cables must have a male XLR connector on one end and a female XLR connector on the other end Duh A Word on Termination DMX is a resilient communication protocol however errors still occasionally occur Termination reduces signal errors and therefore best practices include use of a terminator in all circumstances If you are experiencing pro
7. ation where the source connects to the input of the first device the output of the first device connects to the input of the next device and so on The standard allows for up to 32 devices on a single DMX link Each receiving device typically has a means for setting the starting channel number that it will respond to For example if two 6 channel fixtures are used the first fixture might be set to start at channel 1 so it would respond to DMX channels 1 through 6 and the next fixture would be set to start at channel 7 so it would respond to channels 7 through 12 Troubleshooting Solution Fixture Auto Check the fan in the fixture If it is stopped or moving slower than Shut Off normal the unit may have shut itself off due to high heat This is to protect the fixture from overheating Clear the fan of obstructions or return the unit for service Beam is Dim Check optical system and clean excess dust grime Also ensure that the 220V 110V switch is in the correct position if applicable No Light Output Check to ensure fixture is operating under correct mode IE sound active auto DMX Etc if applicable Contact service for more infor mation Chase Speed Too Check to ensure proper setup of speed adjustment Fast Slow No Power Check fuse AC cord and circuit for malfunction No Response to Verify that the fixture is in Sound Active mode Audio Adjust Audio Sensitivity If Applicable Fixture Not Make sure all con
8. blems with erratic fixture behavior especially over long signal cable runs a terminator may help improve performance To build your own DMX Terminator Obtain a 120 ohm 1 4 watt resistor and wire it between pins 2 amp 3 of the O last fixture They are also readily O available from specialty retailers j 120 ohm 1 4 watt resistor CAUTION Do not allow contact between the common and the fix ture s chassis ground Grounding the common can cause a ground loop and your fixture may perform erratically Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other 3 Pin 5 Pin Huh If you use a controller with a 5 pin DMX output connector you will need to use a 5 pin to 3 pin adapter They are widely available over the internet and from specialty retailers If you d like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female 5 Pin Male Output Input Ground Shiel TET eS Take It To The Next Level Setting Up DMX Control Step 1 Connect the male connector of the DMX cable to the female connector output on the controller Step 2 Connect the female connector of the DMX cable to the first fixture s male connec tor input Note It doesn t matter which fixture address is the first one connected We recommend connecting the fixtures in terms of their proximity to the controller rat
9. color table 2 Enter a 3 digit DMX address 001 512 3 Now you ll see the LEDs flash 3 times per digit you enter and notably they will flash the assigned static color that corresponds to that digit For example setting the fixture to the DMX address of 010 the flashes would be white zero red one white zero See static color table You can use the remote control while in DMX mode to switch to any other mode Press the lt D gt button on the remote to return to DMX mode Static Colors To use fixture in static color mode press either the lt R gt lt G gt or lt B gt buttons and then one of the numeric buttons 0 9 The color table below shows the static color for each number Static color table Button 0 Button 1 Button 2 Button 3 Button 4 Button 5 Button 6 Button 7 Button 8 Button 9 Po oen tue rule rk vew DMX Mode The Motif Fresco will automatically recognizes a DMX signal when connected to a controller and will function in 3 channel RGB color mixing mode If the DMX signal is lost the fixture will revert to its previously set mode You can use the remote control while in DMX mode to switch to any other mode Then to return to DMX mode press the lt D gt button Page 13 Motif Fresco Manual Rev A Copyright c 2014 Blizzard Lighting LLC Blackout The blackout button on the remote control lt B gt will turn off the LEDs regard less of what mode you a
10. e is enough room for ventilation It is important never to obstruct the fan or vents pathway Mount the fixture using a suitable C or O type clamp The clamp should be rated to hold at least 10x the fixture s weight to ensure structural sta bility Do not mount to surfaces with unknown strength and ensure properly rated rigging is used when mounting fixutres overhead Adjust the angle of the fixture by loosening both knobs and tilting the fixture After finding the desired position retighten both knobs e When selecting installation location take into consideration lamp replacement access if applicable and routine maintenance e Safety cables MUST ALWAYS be used e Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation Page 9 Motif Fresco Manual Rev A Copyright c 2014 Blizzard Lighting LLC 4 OPERATING ADJUSTMENTS The Control Panel All the goodies and different modes possible with this fixture can be accessed by using the control panel on the side of the fixture There are 4 control buttons below the LED display which allow you to navigate through the various control panel menus MODE SETUP DOWN O000 Is used to navigate the various modes lt MODE gt lt SETUP gt Is used to enter into the selected mode setup lt UP gt Scrolls through menu items and numbers in ascending order lt DOWN gt Scrolls th
11. ge 17 Motif Fresco Manual Rev A Copyright c 2014 Blizzard Lighting LLC Tech Specs Width Weight Operating Voltage 100 240VAC 50 60 Hertz Power Consumption 44W 68A LED 14x 3 watt TRI color LEDs 100 000 hours Beam Angle 28 degrees Luminous Intensity All Red 2m 515 820 900 2 010 Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Coolness Factor Muy Fresco 2 year limited warranty does not cover Warranty malfunction caused by damage to LED s Page 18 Motif Fresco Manual Rev A Copyright c 2014 Blizzard Lighting LLC Dimensional Drawings Fixture casing dimensions 1181n lt gt 29 6 cm r 4 73 in 12cm a OR LI TING Pointing the Motif Fresco straight up lights up brackets to face 5 32 in 13 5 cm we sincerely appreciate you choosing our products so from all of us everything in this manual is copyright 2014 blizzard lighting IIc motif fresco and blizzard are TM and or A blizzard lighting IIc trees are beautiful and finite please recycle this manual if you aren t going to bother reading it 3 NO HUCLA
12. her than connecting the lowest fixture number first and so on First Fixture in Chain Next Fixture in Chain Step 3 Connect other fixtures in the chain from output to input as above Place a DMX terminator on the output of the final fixture to ensure best communication DMX IN DMX OUT To Next Fixture Page 8 Motif Fresco Manual Rev A Copyright c 2014 Blizzard Lighting LLC Fixture Linking Master Slave Mode 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming from the first fixture which will have a female 3 pin connec tor to the input connector of the next fixture con sisting of a male 3 pin connector Then proceed to connect from the output as stated above to the input of the following fixture and so on A quick note Often the setup for Master Slave and Standalone operation requires that the first fixture in the chain be initialized for this purpose via either settings in the control panel or DIP switches Secondarily the fixtures that follow may also re DMX IN DIC OUT quire a slave setting First Fixture in Chain DMX IN Next Fixture in Chain To Next Fixture Check the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting and Rigging This fixture may be mounted in any SAFE position provided ther
13. iceable parts inside the unit Do not open the housing or attempt any repairs yourself In the unlikely event your unit may require service please contact Blizzard Lighting at sup port blizzardlighting com Page 4 Motif Fresco Manual Rev A Copyright c 2014 Blizzard Lighting LLC 2 MEET THE MOTIF FRESCO MAIN FEATURES e Exceptional color mixing from 14x 3 watt TRI color LEDs e Advanced heat sink design for zero fan noise e Multiple built in color presets and auto programs e User adjustable program speed amp fade times e 0 100 variable electronic dimmer e Variable electronic strobe e Durable cast aluminum housing and mounting brackets e Tempered glass lens and watertight internal gaskets e Built like a rock It hits the gym regularly e USITT DMX 512 3 channels e 3 pin Input Output e Easy to use IR remote control sold separately DMX Quick Reference 3 Channel Mode Channel What is does Red Intensity 0 lt gt 100 Green Intensity 0 lt gt 100 Blue Intensity 0 lt gt 100 DMX Quick Reference 5 Channel Mode Channel What is does a Blue intensity gt 400 5 srove Sow lt gt reso OOOO DMX Quick Reference 7 Channel Mode Channel What is does Master Dimmer 0 lt gt 100 Red Intensity 0 lt gt 100 Green Intensity 0 lt gt 100 5 euen Programs SSCS fs _ Speed Slow lt gt Fast OOOO Page 5 Motif Fresco Manual Rev A
14. ill increase the intensity and lt gt button will decrease the intensity Slave Mode To set the fixture to run in slave mode push the lt SL gt button The fixture is now in slave mode Restore Factory Settings To restore the Motif Fresco back to its factory installed settings with the remote control first press the blackout button lt BL gt to turn off the LEDs Then press the numeric keys lt 9 gt lt 8 gt and lt 7 gt in that order Page 14 Motif Fresco Manual Rev A Copyright c 2014 Blizzard Lighting LLC DMX Values In Depth 7 Channel Mode Channel Channel Value What it does 000 lt gt 029 Channels 1 4 Dimmer Red Green Blue 030 lt gt 059 Auto Mode 060 lt gt 089 Program 2 090 lt gt 119 Program 3 120 lt gt 149 Program 4 150 lt gt 179 Program 5 180 lt gt 209 Program 6 210 lt gt 255 Program 7 000 lt gt 255 Speed Slow lt gt Fast 7 000 lt gt 255 Strobe Slow lt gt Fast DMX Values In Depth 5 Channel Mode Channel Channel Value What it does 000 lt gt 255 Blue Intensity 0 lt gt 100 000 lt gt 255 Strobe Slow lt gt Fast DMX Values In Depth 3 Channel Mode Channel Channel Value What it does 000 lt gt 255 Red Intensity 0 lt gt 100 000 lt gt 255 Green Intensity 0 lt gt 100 000 lt gt 255 Blue Intensity 0 lt gt 100 Page 15 Motif Fresco Manual Re
15. nectors are seated properly and securely Responding Use Only DMX Cables Responding Er Install a Terminator ratically Check all cables for defects Reset fixture s Page 16 Motif Fresco Manual Rev A Copyright c 2014 Blizzard Lighting LLC Heeping Your Motif Fresco As Good As New The fixture you ve received is a rugged tough piece of pro lighting equip ment and as long as you take care of it it will take care of you That said like anything you ll need to take care of it if you want it to operate as designed You should absolutely keep the fixture clean especially if you are using it in an environment with a lot of dust fog haze wild animals wild teenagers or spilled drinks Cleaning the optics routinely with a suitable glass cleaner will greatly improve the quality of light output Keeping the fans free of dust and debris will keep the fixture running cool and prevent damage from overheating In transit keep the fixtures in cases You wouldn t throw a prized guitar drumset or other piece of expensive gear into a gear trailer without a case and similarly you shouldn t even think about doing it with your shiny new light fixtures Common sense and taking care of your fixtures will be the single biggest thing you can do to keep them running at peak performance and let you worry about designing a great light show putting on a great concert or maximizing your cli ent s satisfaction and wow factor
16. re currently running Push the blackout lt B gt button again to return to its previous mode Built in Programs To run one of the six built in programs press the lt SPR gt button You will see the LEDs flash yellow prompting you to then select a program number from buttons lt 2 7 gt on the numeric keys You can also access static color mode from here by pressing button lt 1 gt Built in programs Button 2 Button 3 Button 4 7 Color Fade 3 Color Fade Fantasy Color Fade Button 5 Button 6 Button 7 7 Color Snap 3 Color Snap Various Color Snap Now you can adjust the program speed and flash strobe by pushing their corresponding buttons lt SP gt button for speed and the lt FL gt button for flash Then use the lt gt buttons to adjust the rate The lt gt button will increase the speed and lt gt button will decrease the speed Auto Mode In auto mode the fixture will run the built in programs 2 7 in sequence Press the lt AR gt button to start auto mode Speed and flash setting will be inherited from your settings in program mode Manual Color Adjustment This allows you to adjust the color balance of the fixture These settings are global they will effect all modes To adjust the intensity levels of red green or blue 0 100 press either the lt R gt lt G gt or lt B gt buttons on the remote control Then use the lt gt buttons to adjust the intensity The lt gt button w
17. rough menu items and numbers in descending order The control panel LED display shows the menu items listed on the control panel menu structure on page 11 Use the lt MODE gt button to navigate your choices To edit a setting push the lt SETUP gt button then use the lt UP gt and lt DOWN gt buttons again to scroll through your options Page 10 Motif Fresco Manual Rev A Copyright c 2014 Blizzard Lighting LLC Control Panel Menu Structure Note The menu will automatically LOCK after 10 seconds of inactivity To unlock the menu press and hold lt MODE gt lt SETUP gt for 2 seconds dog i dog i d5 id To choose the DMX address dH To choose 3 channel DMX mode S TH To choose 5 channel DMX mode LH To choose 7 channel DMX mode G Au gt Sets the fixture to run in slave mode Blue Intensity 0 lt gt 100 Pr I Static colors 1 Programs 2 7 PO i SPFL Speed adjustment slow lt gt fast 00 F599 strobe speed slow lt gt fast Lolr rode 255 Red Intensity 0 lt gt 100 Oo 25 Green Intensity 0 lt gt 100 G00 b255 marr FUL LA gt Auto mode DMX Mode Allows the unit to be controlled by any universal DMX controller 1 The default mode for the fixture is DMX which appears as dOO1 on the LED read out To select a different DMX address hit the lt SETUP gt button and use the lt UP DOWN gt buttons to select the your desired starting DMX address ranging from d0O1
18. settings of FSOO FS99 slow lt gt fast Auto Mode 1 To set the fixture to run in auto mode use the lt MODE gt button to scroll to AUTO and hit lt SETUP gt Manual Color Adjustment Allows the user to adjust the color balance of the fixture These settings are global they will effect all modes 1 Use the lt MODE gt button to navigate to Colr and hit the lt SETUP gt button 2 From here you can navigate to r255 9255 or b255 and use the lt UP DOWN gt buttons to adjust the global intensity of red green or blue from 000 255 Restore Factory Settings 1 First unplug the power to the fixture so the fixture is off 2 Press and hold down the lt MODE gt and lt SETUP gt buttons together 3 While still holding down the two buttons plug the power back in Data restoration will initialize resetting the unit back to its original factory settings Page 12 Motif Fresco Manual Rev A Copyright c 2014 Blizzard Lighting LLC Using The Remote Control All the goodies and different modes possible with the Motif Fresco are also acces sible by using the IR remote control sold separately Setting the DMX Address 1 To set the starting DMX address push the lt S gt button You ll see the LEDs flash 3 times in a sequence of colors that indicate the currently set DMX address For example if the DMX address is currently 001 the flashes would be white zero white zero red one See static
19. this product e Please keep this User Guide for future use If you sell the unit to someone else be sure that they also receive this User Guide e ALWAYS make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on the de cal or rear panel of the fixture e Make sure there are no flammable materials close to the unit while operating e The unit must be installed in a location with adequate ventilation at least 20in 50cm from adjacent surfaces Be sure that no ventilation slots are blocked e ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type e ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles e DO NOT operate at ambient temperatures higher than 104 F 40 C e In the event of a serious operating problem stop using the unit immediately NEVER try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized tech nical assistance center Always use the same type spare parts e NEVER connect the device to a dimmer pack e Make sure the power cord is never crimped or damaged e Never disconnect the power cord by pulling or tugging on the cord e Avoid direct eye exposure to the light source while it is on Caution There are no user serv
20. v A Copyright c 2014 Blizzard Lighting LLC 5 APPENDIX A Quick Lesson On DMX DMX covers and is an abbreviation for Digital Multiplexed signals It is the most common communications standard used by lighting and related stage equipment DMX provides up to 512 control channels per data link Each of these channels was originally intended to control lamp dimmer levels You can think of it as 512 faders ona lighting console connected to 512 light bulbs Each slider s position is sent over the data link as an 8 bit number having a value between 0 and 255 The value 0 corresponds to the light bulb being completely off while 255 corresponds to the light bulb being fully on DMX data is transmitted at 250 000 bits per second using the RS 485 transmission standard over two wires As with microphone cables a grounded cable shield is used to prevent interference with other signals There are five pins on a DMX connector a wire for ground cable shield two wires for Primary communication which goes from a DMX source to a DMX receiver and two wires for a Secondary communication which goes from a DMX receiver back to a DMX source Generally the Secondary channel is not used so data flows only from sources to receivers Hence most of us are most familiar with DMX 512 as being employer over typical 3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configur
21. y are they need to be purchased separately Contact your favorite Blizzard Lighting dealer for pricing Motif Fresco Remote IR Remote Control CABLE_MotifData3M 3M IP Rated DMX Extension CABLE_MotifDMXSET 1M IP Rated DMX IN OUT Set CABLE_MotifPower3M 3M IP Rated Power Extension Getting It Out Of The Box Congratulations on purchasing one of the brightest cutest little outdoor rated fixtures anywhere Now that you ve got your Motif Fresco or hopefully Fresco s you should carefully unpack the box and check the contents to ensure that all parts are present and in good condition If anything looks as if it has been damaged in transit notify the shipper immediately and keep the packing material for inspection Again please save the carton and all packing materials If a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing Powering Up All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the fixture you receive is suitable for your local power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under

Download Pdf Manuals

image

Related Search

Related Contents

User manual Fire alarm system EBL128 EBL128  020-499-UK LH 500 Tractor monitor operators manual  le sylvopastoralisme ou comment allier agriculture et sylviculture      Qware AC Power adapter  Intel Celeron 440  User manual of DS-2CC52A2P(N)-IT3  Divar - Digital Versatile Recorder  D-Series Clamps - Cascade Corporation  