Home
Part Numbers: 4521 USER MANUAL
Contents
1. any failure to conform to such specifications samples descriptions or illustrations shall not constitute any breach of Offshore Systems limited warranty WARRANTY RETURN PROCEDURE To apply for warranty claims contact Offshore Systems or one of its dealers to describe the problem and determine the appropriate course of action If a return is necessary place the product in its original packaging together with proof of purchase and send to an Authorized Offshore Systems Service Location You are responsible for all shipping and insurance charges Offshore Systems will return the replaced or repaired product with all shipping and handling prepaid except for requests requiring expedited shipping i e overnight shipments Failure to follow this warranty return procedure could result in the product s warranty becoming null and void Offshore Systems reserves the right to modify or replace at its sole discretion without prior notification the warranty listed above 10 of 11 8 TECHNICAL SUPPORT If you require technical support for any Offshore Systems products you can reach us using any of the following ways e Tel 44 0 1425 610022 e Fax 44 0 1425 614794 e Email support osukl com e Web www osukl com e Post Offshore Systems UK Ltd Unit 10 11 Milton Business Centre Wick Drive New Milton Hampshire BH25 6RH Bed on binge miah eet Te Up be t5 of eah type of Serer can ba bert EE A lt l
2. GNS 126464 PGN List 126996 Product Information 126998 Configuration Information Protocol PGNs 059392 ISO Acknowledge 059904 ISO Request 060928 ISO Address Claim 065240 ISO Address Command 126208 Complex Command Electrical and Mechanical Parameter Value Comment Operating Voltage 9 to 32 Volts DC Voltage Power Consumption 100mA Average Operating Load Equivalence Number 2 LEN Reverse Battery Protection Yes Indefinately Load Dump Protection Yes SAE J1113 Size 120x100x35mm Weight 160gm 7 of 11 8 of 11 Environmental Parameter Value IEC 60954 Classification Protected Degree of Protection IP40 Operating Temperature Storage Temperature 25 C to 50 C 40 C to 70 C Relative Humidity 93 RH 40 per IEC60945 8 2 Vibration 2 13 2Hz 1mm 13 2 100Hz 7m s2 per IEC 60945 8 7 Electromagnetic Emission Conducted and Radiated Emission per IEC 60945 9 Electromagnetic Immunity Conducted Radiated Supply and ESD per IEC 60945 10 Safety Precautions Dangerous Voltage Electromagnetic Radio Frequency per IEC 60945 12 9 of 11 WARRANTY Offshore Systems warrants this product to be free from defects in materials and workmanship for one year from the date of original purchase If within the applicable period any such products shall be proved to Offshore Systems satisfaction to fail to me
3. NMEA2000 4 CHANNEL TEMPERATURE MODULE Part Numbers 4521 fS OVE USER MANUAL ive CEE NMEA2000e TEMPERATURE MODULE 4 CHANNEL Part No 4521 NMEA2000 interface 9 32 V LEN 2 Made in the United Kingdom Offshore Systems UK Ltd Web www osukl com_ Tel 44 0 1425 610022 NMEA Connector NMEA IO E ermmereoples E Eo DE ae Revision 1 01 2 of 11 gy INTRODUCTION The Offshore System s NMEA2000 4 Channel Temperature Module part no 4521 measures temperatures using type K thermocouples and transmits standard NNMEA2000 temperature Introduction messages to the network Firmware Revision PEN l This unit is designed to operate in a protected marine environment such as an engine room Product Features or below decks It is very important that it is installed and set up correctly according to this i manual Please read and follow the installation and setup instructions carefully to achieve the Installation best results Unpacking the box The information in this manual corresponds to firmware revision 1 0 0 Choosing the mounting location Connecting the NMEA20000 Interface 1 1 Product Features The 4521 NMEA2000 4 Channel Temperature Module has the following features Connecting the thermocouple cables e NMEA2000 Interface e Panel Mount or DIN Rail mount enclosure NMEA2000 Device Instance e 4 temperature input channels e Has a blue LED to indicate transmission of temperature data Temperature Insta
4. elow and is worked out using this formula Device Instance No x4 Channel Number Temperature Instance Device Formula Channel Channel Channel Channel Instance 0 IMI OUILAIL WI YD OlSOI nN I ans ol RI wl ni 4 of 11 3 3 Temperature Channel Source FRONT PANEL INDICATORS Each of the four channels can have a source identity programmed to indicate the source of the temperature information These are as follows Each thermocouple connection has a red LED associated with it that will light if the thermocouple cable has been damaged or is not making a good connection If this occurs then check that the cable is seated correctly in the WAGO cage clamp and that the run of the cable is undamaged If the red LED is on after those checks then replace the temperature sender as it might have failed internally Temperature Source Config Value Sea Temperature Outside Temperature Inside Temperature Engine Room Temperature Main Cabin Temperature Live Well Temperature Bait Well Temperature Refrigeration Temperature Heating System Temperature Dew Point Temperature Wind Chill Temperature Apparent Wind Chill Temperature Theoretical Heat Index Temperature Freezer Temperature Exhaust Gas Temperature TAI MI DVLA WI YP oOlLoOI INI A o A wln i o Not in Use In order to set a temperature chan
5. et the above limited warranty such products shall be repaired or replaced at Offshore Systems option Purchaser s exclusive remedy and Offshore Systems sole obligation hereunder provided product is returned pursuant to the return requirements below shall be limited to the repair or replacement at Offshore Systems option of any product not meeting the above limited warranty and which is returned to Offshore Systems or if Offshore Systems is unable to deliver a replacement that is free from defects in materials or workmanship Purchaser s payment for such product will be refunded Offshore Systems assumes no liability whatsoever for expenses of removing any defective product or part or for installing the repaired product or part or a replacement therefore or for any loss or damage to equipment in connection with which Offshore Systems products or parts shall be used The foregoing warranties shall not apply with respect to products subjected to negligence misuse misapplication accident damages by circumstances beyond Offshore Systems control to improper installation operation maintenance or storage or to other than normal use or service THE FOREGOING WARRANTIES ARE EXPRESSLY IN LIEU OF AND EXCLUDES ALL OTHER EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE Statements made by any person including representatives of Offshore Systems which are i
6. kbone 3802 T Adaptor NMEA2000e TEMPERATURE MODULE 4 CHANNEL Part No 4521 NMEA2000 interface 9 32 V LEN 2 Made in the United Kingdom Offshore Systems UK Ltd Web www osukl com_ Tel 44 0 1425 610022 Thermocouples NMEA Connector NMEA meee ee Instance Config GIA Tx OOo 2 4 Connecting the thermocouple cables The thermocouple cables should be attached to the WAGO cage clamp terminal block being careful to connect the green wire to the terminal marked GR and the white wire to the terminal marked WH next to it The WAGO cage clamp terminals are opened by using a small screwdriver in the uppermost slot to open the cage clamp in the lower slot Insert a suitably stripped wire end into the cage clamp then release the cage clamp by removing the small screwdriver 3 of 11 CONFIGURATION id 3 1 NMEA2000 Device Instance NMEA2000 requires a unique Device Instance for each 4521 NMEA2000 4 channel Temperature Module on a single network This is settable from device instance 0 to Device Instance 15 using the left hand small rotary switch on the front panel labeled NMEA Instance This can be set at any time regardless if power is on or off The switch counts from 0 9 then A F being equivalent to Device Instance 10 15 3 2 Temperature Instance On setting the Device Instance 3 1 the Device Temperature Instance is determined as follows Temperature Instance number is shown the table b
7. nce e User configurable to temperature type without needing any external equipment e Has a red warning light for each channel to warn of damaged cables CONTIGUPAUION s cicssccudacessseccucesedestevscabesseaeeswences 4 Temperature Channel Source Front Panel Indicators Maintenance Technical Specification Warranty Technical Support 1 of 11 2 of 11 INSTALLATION lh 2 1 Unpacking the box The following items are in the 4521 shipping box 1 x 4521 NMEA2000 4 Channel Temperature Module 1 x pair DIN rail mounting clips 4x M3x6mm screws 1 x 4521 User Manual This document 2 2 Choosing the mounting location The unit is designed to be mounted on a panel or a DIN rail in an electrical cabinet with free air circulation in a dry location below decks The cabinet may be located in an engine room providing the ambient temperature does not exceed 50 C 125 F The location needs to allow for connection to the NMEA2000 interface cable and the thermocouple cables 2 3 Connecting the NMEA2000 Interface The NMEA2000 interface cable on the unit should be connected to a nearby NMEA2000 Tee connector part number 3802 The male end of the cable should be inserted into the female Tee connection noting the position of the keyway in the plug and the socket The unit can be connected with power on or off without any damage Ensure that the locking ring is securely tightened so that the connection remains sound NMEA2000 Network Bac
8. nconsistent or in conflict with the terms of this Limited Warranty shall not be binding upon Offshore Systems unless reduced to writing and approved by an officer of Offshore Systems IN NO CASE WILL OFFSHORE SYSTEMS BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES DAMAGES FOR LOSS OF USE LOSS OF ANTICIPATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE INNO EVENT SHALL OFFSHORE SYSTEMS AGGREGATE LIABILITY EXCEED THE PURCHASE PRICE OF THE PRODUCT S INVOLVED OFFSHORE SYSTEMS SHALL NOT BE SUBJECT TO ANY OTHER OBLIGATIONS OR LIABILITIES WHETHER ARISING OUT OF BREACH OF CONTRACT OR WARRANTY TORT INCLUDING NEGLIGENCE OR OTHER THEORIES OF LAW WITH RESPECT TO PRODUCTS SOLD OR SERVICES RENDERED BY OFFSHORE SYSTEMS OR ANY UNDERTAKINGS ACTS OR OMISSIONS RELATING THERETO Offshore Systems does not warrant that the functions contained in any software programs or products will meet purchaser s requirements or that the operation of the software programs or products will be uninterrupted or error free Purchaser assumes responsibility for the selection of the software programs or products to achieve the intended results and for the installation use and results obtained from said programs or products No specifications samples descriptions or illustrations provided by Offshore Systems to Purchaser whether directly in trade literature brochures or other documentation shall be construed as warranties of any kind and
9. nel to the desired channel source information follow these simple steps e Turn the NMEA Instance Switch to the chosen channel e Turn the Config switch to the desired source identity and press the Config button identity as per table e When you have configured the channels then reset the NMEA Instance Switch to it s original setting 5 of 11 6 of 11 5 MAINTENANCE 6 TECHNICAL SPECIFICATION e Clean the unit with a soft cloth As Offshore Systems are constantly improving their products as specifications are subject to e Do not use chemical cleaners as they may remove paint or markings or may corrode change without notice Offshore System s products are designed to be accurate and reliable the enclosure or seals however they should only be used as aids to navigation and not as a replacement for traditional e Ensure that the unit is mounted securely and cannot be moved relative to the navigation aids and techniques mounting surface If the unit is loose tighten the mounting screws e Check the security of the cables connected to the NNMEA2000 connector and the l i Design Standard WAGO connector and tighten if necessary Parameter Comment NMEA2000 Level B Maritime Nav and RadioComm Equipment IEC60945 CE and FCC Electromagnetic Compatibility NMEA2000 Transmitted Parameter Group Numbers PGNs Description PGN No PGN Name Temperature 130312 Temperature 130316 Temperature extended range Requested P
10. t i z Lit Lai W Lid it 3 Offshore Systems UK Ltd Unit 10 11 Milton Business Centre Wick Drive New Milton Hampshire BH25 6RH United Kingdom Tel 44 0 1425 610022 Fax 44 0 1425 614794 Email mail osukl com Web www osukl com OFFSHORE SYSTEMS PRODUCT MAP Copyright 2015 Offshore Systems UK Ltd All rights reserved Our policy is one of continuous product improvement so product specifications are subject to change without notice Offshore Systems products are designed to be accurate and reliable However they should be used only as aids to vessel monitoring and not as a replacement for traditional navigation and vessel monitoring techniques NMEA2000 is a registered trademark of the National Marine Electronics Association 11 of 11 12 of 11