Home
MAINTENANCE & CARE OF YOUR SYSTEM
Contents
1. f pluas into socket here Terminal for extra low l voltage wires from inlets When the hose is plugged into the inlet valve inside the house the power unit is activated Exhaust Mounting outlet bracket for from power unit motor Pipe entry from house On Off switch for using the inlet at the vacuum unit Filter to protect motor and keep dust in the dust bucket Bucket clips Unlatch to remove dust bucket Dust bucket Filter screw to allow easy removal of filter for cleanng Cyclonic cone to direct dust into the bucket Direct Alarm Supplies DAS VAC User Guide MAINTENANCE amp CARE OF YOUR SYSTEM Your power unit is warranted against defective materials and workmanship but not against misuse There is a service charge for repairing or replacing damaged or misused components of the system or for unnecessary service calls 1 Do not suck up flammable and non flammable liquids chemicals cement lime and plaster powders 2 Do not leave the central vacuum system on unattended 3 Use only one inlet at a time to maintain maximum suction 4 Hold the inlet door open for five 5 seconds after removing the hose This will make sure that the unit has stopped and clear any residual dirt out of the pipe system 5 To empty the dust bucket undo both clips and lower the bucket Remove the cone and empty the bucket Replacement is the reverse of this procedure 6
2. DA Ducted Vacuum Congratulations You have joined the growing number of households to enjoy the many benefits of owning a DAS Ducted Vacuum System Your DAS Ducted Vacuum System is a lifestyle improvement for you and your family Follow these simple maintenance and care instructions for trouble free vacuuming for many years to come OPERATING YOUR DUCTED VACUUM SYSTEM Inside the Home 1 Plugin the cuff end of the hose into the nearest wall inlet inside your home and the power unit will automatically turn on ready for you to begin vacuuming 2 The power unit also has an on off switch which should be in the off position 3 When you have finished vacuuming simply unplug the cuff of the hose out of the inlet and hold the door of the inlet open for five 5 seconds until the suction subsides Note This vacuum is not intended for use by young children or infirmed persons without supervision Young children should be supervised to ensure that they do not play with the vacuum 1 Direct Alarm Supplies DAS VAC User Guide At the Vacuum Power Unit 1 Insert the hose cuff into the inlet adjacent to the vacuum power unit 2 Turn the unit on using the ON OFF switch When finished turn the switch to the OFF position again Note To use the inlets inside the house the switch must be in the OFF position Reset switch if system shuts down due to overload or high running temperatures 240 Volt AC IEC Power lead r
3. Each time you empty the bucket or if the suction is diminished you must clean or replace the filter To remove the filter remove the dust bucket to gain access to the filter Unscrew the filter holder anticlockwise and pull the filter down Replacement is the reverse of this procedure Sponge filters can be washed using cold water only Allow it to dry thoroughly before reinstalling If Cartridge filters are used you may attempt to remove excess dust by shaking and brushing If this is unsuccessful and the filter is unserviceable it should be replaced Please note a spare filter is supplied with your new vacuum 3 Direct Alarm Supplies DAS VAC User Guide Additional filters are available through your Installation Company The filter must be reinstalled before using your vacuum Using the vacuum without the filter could result in permanent damage to the motor and void any warranties 7 Empty dust bucket periodically or when dust reaches 5cm from bottom of cone 8 Do not store property on top of power unit as this will restrict the cooling airflow which may cause the motor to over heat Do not use the system if a blockage occurs 9 Read the Warranty Card 4 Direct Alarm Supplies DAS VAC User Guide WARRANTY This Ducted Vacuum has been built to DAS specification from quality materials It is warranted to be free of defects in materials workmanship and mechanical performance for a period of one 1 year from the dat
4. e of purchase for domestic installations and 500 hours operation for commercial installations This warranty is additional to any statutory requirements Warranty Conditions This warranty applies only to the DAS Ducted Vacuum unit It does not apply to piping and fittings All warranty claims must be accompanied by original proof of purchase The vacuum must have been used in accordance with the User Guide and maintenance instructions All costs associated with the transport of goods under warranty claim are the responsibility of the claimant DAS reserve the right to repair or replace goods at its own discretion DAS reserve the right to act as final arbiter in all warranty claims Their warranty does not apply if the defect occurs as a result of Misuse neglect or accidental damage Scratches dents or blemishes which occur after the purchase date The unit being used for any other purpose other than that for which it was designed 5 Direct Alarm Supplies DAS VAC User Guide
Download Pdf Manuals
Related Search
Related Contents
Orion CO154S subwoofer TV TDT 9” y TV LCD Analógico Samsung Blu-ray-spelare BD-F8900N Bruksanvisning ADNK-2133 - Digi-Key ExecuTech Model 616 and 616B Installation Copyright © All rights reserved.
Failed to retrieve file