Home

USER MANUAL LL ARC FLEXI LINE

image

Contents

1. You can suffer a dangerous electric shock by using a high voltage AC DC power supply by touching the AC DC power supply wires inside LL ARC FLEXI LINE LLARC FLEXI LINE can be operated in two ways 03 3 1 LLARC FLEXI LINE connecting to DC POWER SUPPLY for switch ON OFF luminaries 03 3 2 LL ARC FLEXI LINE connecting to LL ARC DRIVER for intensity and colour control 03 3 1 Connecting to DC power supply Figure Nr 1 1 LL FLEXI LINE must be connected to the device MW power supply IN 100 260AC OUT 24V AC Power Supply Cord plug connections to MW Power supply Wire Colour Screw US L live brown yellow or brass N neutral blue silver Se ground earth 03 3 2 Connecting to LL ARC DRIVER Figure Nr 1 2 yellow green green For intensity and colour control is necessary connection with LLARC DRIVER It is not necessary to open fixture before connecting to LL ARC DRIVER Before installing of LL ARC DRIVER carefully read USER MANUAL for LL ARC DRIVER If you have any question please contact support leaderlight sk Order code Product name Current LL ARC FLEXI LINE One colour connecting to DIN POWER SUPPLY enables to switch ON OFF luminaries LL40 100 LLARC FLEXI LINE RGB 3x1 00A LL40 110 LLARC FLEXI LINE N 3x1 00A FLEXI LINE LL40 120 LLARC FLEXI LINE W 3x1 00A DIN oa POWER Accessories SUPPLY LL41 800 LL ACCESSORIES PACK FLEXI LINE 5xend cup 15xclip MW
2. Net weight Ambient temp Ta Cooling Materials and finish Installation Materials and finish Installation 5000mm 300 x RGB N W TOP LED Long 50 000 120 3 1 channels 24V dimming max 72W 24V DC PWM 1kg max 40 C Conventional High flefible plastic Surface mounting High flefible plastic Any position for ceiling wall and surface mounting Note Cutting distance 100mm TOP LED M R Red I G Green W B Blue N Neutral White 3000 K W White 6300 K Edition A 2010 03 INSTALLATION 03 1 Unpacking Unpack carefully This is electronic equipment and should be handled carefully Damaged delivered package or if are any mechanical parts broken it must be claim immediately by the transport company Photo pictures as evidence are valuable or future claim 03 2 Physical installation Loading capacity of bearing area has to be at least 10 times the weight of all device clusters luminaries clamps cables Hairbreadth from combustible materials is 0 5m LED strip fasten to the surface by the self adhesive 3M sticky tape or with clear clips distance cca 300mm end cup cca 310mm lt gt 5 a _V oo ooo o o oo o o o 2m O LO N clip clip width 0 5mm LL ACCESSORIES PACK 15xclear clips and 5xclear end cups 03 3 Electrical installation A To tackle all Safety Information 01
3. 240 FLEXI LINE DIN 24V max 10A 100 260V AC 1 1 LL ARC FLEXI LINE connecting to PWM DRIVER and DIN POWER SUPPLY enables to switch ON OFF luminaries and in addition intensity and colour control by DMX controller RGB LL ARC FLEXI LINE N W connecting to DC POWER SUPPLY enables to ON OFF z 100 260V AC DC 24V POWER a SUPPLY z DMX 9 CONTR FLEXI LINE RGB ELE i ss 3 A 5 ji B connect max 1 4A per GROUP Uy ij Lie ia FLEXI LINE RGB x H DC 24V DIN POWER MW 240 DIN 24V FLEXI LINE N W 100 260V AC LL ARC FLEXI LINE RGB connecting to controller and DC POWER SUPPLY 100 260V AC White 1 2 4 cor cable or 2 core cable 04 MAINTENANCE ZN To tackle all Safety Information 01 Damage caused by inadequate cleaning or maintenance is not coverd by warranty Regular cleaning is demand dust dirt High brightness TOP LED Product Colour LED QTY 1m Lumen 1m_ Voltage Power 1m D med 129 Maintenance policy R LL ARC FLEXI LINE RGB Green 60 240 DC24V 14 4 W Unplug mains before maintenance and at least 10 minutes cool off c BI 150 Appliance do not illegal open or demount amp B ue Clean up dust only from outer surface LLARC FLEXI LINEN Neutral White 60 1080 DC24V 14 4 W Use vacuum or dumpy duster warm water oS AR a SES Te NS Se
4. Te Bef installing to check failure f tate t parts LLARC FLEXI LINE W White 60 1170 Dc24v 14 4 W Poi ures ag ere weg ernie nts tenner Mase euzn Seen If you have any question please contact support leaderlight sk
5. Leader Light s r o M Gorkeho 33 SK 052 01 Spisska Nova Ves Slovakia www leaderlight eu USER MANUAL LEADER LICHT professional lighting products LL ARC FLEXI LINE LL40 100 LL40 110 COMPLIMENTS ON YOUR PURCHASE All dimensions are in milimeters n ik A oee 2 1 cutting distance 100mm Following items are included LL ARC FLEXI LINE with 5 m cable and 6pin LINE connector 1 pc User manual 1 pc Additional items needed LL ARC DRIVER DC power supply 24V Controller compatible with DMX LL ARC FLEXI LINE accessories end cups clips Self adhesive 3M sticky tape Content 01 SAFETY INFORMATION 01 1 Risk of eyes damage 01 2 Protection from electric shock 01 3 Fire prevention 02 PRODUCT SPECIFICATION 02 1 Technical Specification 03 INSTALLATION 03 1 Unpacking 03 2 Physical installation 03 3 Electrical installation 03 3 1 Connecting to AC DC power supply 03 3 2 Connecting to LL ARC DRIVER for intensity colour control 04 MAINTENANCE ENVIRONMENT H E Do not throw away the appliance with the normal household waste at the end of its life but hand it in at an official collection point for recycling By doing this you help to preserve the environment MMxX Leader Light All right reserved 01 SAFETY INFORMATION A WARNING Carefully read before installing powering or servicing Nothing to do if anything misunderstand Installation can be done
6. only by a qualified professional in accordance with relevant local codes 01 1 Risk of eyes damage A Do not look directly into LED lamps Do not look into light beam from a distance of less than 40 cm 16 inches 01 2 Protection from electric shock A Shut down power before installation or maintenance Luminaries Driver and recommended power supply must be installed by a qualified professional in accordance with relevant local codes Only acceptable source of power and frequency that complies with local building and electrical codes to use Do not use or do not connect the products if the power cable power plug or fixtures are any way damaged wet or if they are overheating Do not modify alter or attempt to service the LeaderLight appliance Doing so will void the warranty Before removing or installing any cover or part of appliance disconnect from power Operation only with DC 24V source By using a high voltage AC power supply danger of electric shock 01 3 Fire prevention A Follow all safety consideration Thermostatic switches or fuses never to bypass Device never shield minimum distance around fitting must be 50mm 2 in LEDs never direct cover with filters or other materials Allowing max ambient temperature is 40 C 104 F 02 PRODUCT SPECIFICATION 02 1 Technical Specification Lamp type Lifetime View Angle Control data input Input power Power connection

Download Pdf Manuals

image

Related Search

Related Contents

Installation and Configuration Manual  取扱説明書 パワーコンディショナ  Máquina de Hielo Serie VT  VA4x Vision Appliance User`s Reference  Panasonic TC-L32C3 LCD TV  RCA DRC279BK DVD Player User Manual  Audiovox ASH400 Diagram  

Copyright © All rights reserved.
Failed to retrieve file