Home
Manual
Contents
1. Submarine Switch 125VAC 3A max 25 C to 85 C Microswitch Acceptable wire Copper Figure 4 Torque 1 8lb in 0 3kg cn CAUTION Do not attempt to open or tamper with the surge device in any way as this may compromise performance and will void the warranty Megger and hi potential tests may damage the device Disconnect all power supplying the equipment and isolate the device before testing Install for point of use The MA3100 can be used for Type 2 or 3 Class Il or Ill applications according to IEC 61643 1 Operating and storage temperature of this device must be within 25 C and 85 C For more information contact your local MTL rep www mtl inst com contact 801643 Rev C 01 08 10 a COOPER Crouse Hinds MTL INSTALLATION INSTRUCTIONS USER MANUAL MA3100 Series Surge Protection Devices CONGRATULATIONS YOU HAVE JUST PURCHASED THE BEST SURGE PROTECTION IN THE INDUSTRY Adhering to these instructions guarantees maximum performance of this protection device 1 INTRODUCTION These Surge Protective Devices SPD provide surge protection for electrical and automation cabinets They can be mounted on standard 35 mm rail near the incoming power source to isolate the cabinet from the outside environment This product is ideal for manufacturers requiring designed in power protection CAUTION 2 Hazard of EQUIPMENT DAMAGE e Megger or hi potential tests will damage this surge protective device Turn off all pow
2. er supplying the equipment and isolate the surge protective device before testing e Not for use on ungrounded systems Failure to follow these precautions can result in equipment damage 3 INSTALLATION NOTE Follow mounting steps for all 1 Pole 2 Pole and 4 Pole modules e Mount SPD as shown in Figure 1 The MA3100 is designed to mount onto a 35mm DIN rail or top hat rail standard EN 50022 BS 5584 set in the horizontal position To install first hook the line side over the 35mm DIN rail and then push in the load side until the spring loaded mounting clip clicks onto the rail with the label text shown in the upright position reading left to right Confirm SPD is rated for your system by comparing the L N voltage measurements to the Service Voltage Un on the product label e Connect wires as shown in Figure 2 keeping lead lengths as short as possible e Acceptable wire size 14 6 AWG 2 13mm Copper Solid or stranded Maximum torque to be applied to terminal screws is 14 75lbs in 2 6kg cm NOTE Keep conductor length as short as possible with no sharp bends Do not loop or coil wires Figure 1 Mounting Distance D1 D2 20 in 50 cm Figure 2 Lead Lengths 4 REMOVAL lf the blown indicator tab is visible on any of the multiple pole units then the entire unit has reached the end of its life and must be replaced To remove push up on the unit and rock the top off the 35mm DIN rail See Figure 3 Visual Ind
3. icator Figure 3 5 TROUBLESHOOTING Diagnostic Operation e Flag Indicator Fault Check line voltage breakers and connections If OK replace unit e Remote Monitoring Dry Contact option see Figure 4 A three pin socket and plug are provided to allow the customer to wire a set of normally open NO and normally closed NC Dry Contacts to a remote monitoring indicator The customer must provide power for this indicator keeping within the specifications shown in Figure 4 In event of a fault within the SPD the internal mechanical contacts change position NOTE The supplied three pin plug can accept 16 AWG 1 5mm to 30 AWG 05mm 4 wire Voltage Specifications Cat No Service Voltage Dry Un Contacts MA3145 120 1 R 120V Yes MA3145 230 1 R 230V Yes MA3145 120 2 R 120V Yes MA3145 230 2 R 230V Yes MA3145 120 4 R 208 Y 120V Yes MA3145 230 4 R 400 Y 230V Yes
Download Pdf Manuals
Related Search
Manual manual manualslib manual car manual timesheet manual transmission manuale digitale manually meaning manual wheelchair manual arts high school manually update your device drivers windows manual labor manual definition manual for courts martial manual muscle testing manual muscle testing grades manually register devices with autopilot manual keyboard manual blood pressure cuff manualidades manual lawn mower manual transfer switch manual transmission cars for sale manual therapy cpt code manual libs manual autopilot enrollment
Related Contents
Split-2 - Contest Ergotron StyleView® Vertical Lift, High Traffic Areas Using Infortrend EonStor FC-host Storage with HP referentiel de formation professionnelle - UNESCO 10T802-0198-B1 Sélection: Cylindre, culasse Novembre - Collège Notre Dame de Sion I CAMBRISTI ASBL PROCES-VERBAL de L`ASSEMBLEE EM-2511 取扱説明書 BENDIX BW7294S User's Manual Copyright © All rights reserved.
Failed to retrieve file