Home
        Instruction Manual
         Contents
1.    Approx  4 6 cm  B  X 9 3 cm  H  X 5 7 cm  D   Ambient temperature  10  C to 40  C  50  F to 104  F   30   85    Ambient temperature   20  C 60  C   4  F  140  F   30   95    Storage case  Instruction Manual  probe covers   10 pieces    A probe cover is already attached to the main unit   Probe cover exclusively for GentleTemp 510    series  MC PROBE TYPE J       13    GentleTemp 510 English    Subject to technical modification and specifications may be changed  without prior notice     Special Note  If used privately no calibration is needed  For professional use it is  recommended to check once a year     o  C    0197 A    scent    Manufacturer  OMRON HEALTHCARE Co   Ltd   24  Yamanouchi yamanoshita cho  Ukyo ku  Kyoto 615 0084  Japan    EU Representative   OMRON HEALTHCARE EUROPE B V   Kruisweg 577   2132 NA Hoofddorp   The Netherlands   Telephone   31  0  20 3548200  Facsimile   31  0  20 3548201  www omron healthcare com    14       Affiliate Companies   OMRON HEALTHCARE UK LTD   Opal Drive   Fox Milne  Milton Keynes MK15 ODG  United Kingdom   Telephone   44  0  1273 495 033  Facsimile   44  0  1273 495 123    OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH  WindeckstraBe 81a   D 68163 Mannheim   Germany   Telephone   49  0  621 83348 0   Facsimile   49  0  621 83348 30   E Mail  OHGD Info eu omron com  www omron medizintechnik de   PZN  2585192   Artikel Nummer  086 000 000    OMRON Sant   France   14  rue de Lisbonne   F 93561 Rosny sous Bois Cedex  France    
2.    Display    What to check     How to correct        Nothing is displayed  even after   pushed  the blue button           Is the battery flat     Replace the battery  with a new one        Are the polarities of  battery    and     placed incorrectly     Replace the battery  with correct polarities              The battery is    Replace the battery                               Age Normal ear temperature in   C and   F    almost  flat  with a new one    Babies 36 4  C     37 5  C 97 5  F     99 5  F   Children 36 1  C   37 5  C 97  F     99 5  F Is the probe cover Replace the probe  Teens Adults 35 9  C     37 5  C 96 6  F     99 5  F dirty  cover with a new one   Elderly 35 8  C     37 5  C 96 4  F     99 5  F  x  Is the infrared sensor  Clean the infrared sensor       4 3 Ear temperature compared to other types of body temperature        The normal temperature is not the same everywhere        Even after   insert  unit in the ear  the    0       mark is not displayed     dirty     with a cotton swab        Is your ear filled  with earwax     Remove the earwax  with a cotton swab           o O             The temperature of  the main unit is 34  C   93 2    For above        If you insert the unit  in the ear and push the  blue button  you can  measure in 1 second   At this time  you cannot  use the    Information  Mode       11    GentleTemp 510 English                or Did you forget to  re attach the probe cover         Attach the probe cover   then measure        The mea
3.   An ear temperature   unlike an oral temperature  is unaffected by factors such as talking  drinking   and smoking     10       4 2 Normal and raised temperature       We recommend that you practice with the GentleTemp 510   on yourself and  family members    This way you can improve your technique and feel more confident of the  measurements you take when a family member is ill  You will also be able  to tell when a reading is higher than normal     As ambient temperature  sweat  or saliva easily  affects body temperature measured under the arm  or the tongue  readings may be lower than the core  temperature    Tympanic temperature measurement accurately  reflects the brain temperature and can lead to a  quicker detection of fever        Eardrum i             arn   3 4 117   Infrared sensor       Infrared rays        Eardrum Measure point    External auditory canal    GentleTemp 510 English    In order to make a correct judgement of suspected fever conditions  it is  important to learn the normal temperatures of family members by measuring  their temperatures when they are in good physical condition     The temperature measured in the ear is different to that measured rectally   Please use the normal as the standard for understanding the temperature  difference during fever     One speaks of normal body temperature if the measurement value lies with   in a certain range  Body temperature varies however according to age        5 SOLVING PROBLEMS    5 1 Troubleshooting       
4.   for a long time or the thermometer is used  more than three times in a row        How many times can   measure consecutively    You can measure consecutively up to three times  The main unit will then   be warmed up and may not be able to measure correctly  If you are going to  measure more than three times  wait for ten minutes  then measure again     The temperature indicated is rather high    1 The probe cover may be faulty    2 You may have used the thermometer that has been stored in a cool or  cold place  Measure the temperature after leaving the unit in the room  where you are going to use for more than thirty minutes  If you store the  unit in the room where you are going to measure the temperature  you  can use the thermometer promptly     GentleTemp 510 English    Is the temperatures measured in the right ear different from that  measured in the left ear    Among healthy people  there should be no significant difference in the  measurement results  Differences may be caused by the following reasons   1  The infrared sensor is not inserted in the same way    2  Measurement is not conducted by inserting the unit in a stable manner in  the same angle  Try to measure in either ear that can show the highest  measurement value constantly  In accordance with the    10 seconds mode      the unit detects the highest temperature   Refer to paragraph 3 2      The temperature shown is rather low   1 The probe cover is dirty   2 The infrared sensor is dirty   3 You removed the
5.  unit from the ear before the measurement is finished   4 The ear is cold  The temperature tends to indicate low when you use  an ice bag or an ice pack  or immediately after coming in from the  cold in winter   The thermometer is not inserted deep enough in the ear   6 The infrared sensor is not directed towards the eardrum    Use the 10 seconds measurement mode  Refer to paragraph 3 2      a    6 SPECIFICATIONS    Name  GentleTemp 510    Model  MC 510 E2   Voltage  3V DC  lithium battery CR2032   Power consumption  0 05 W    Battery life    Sensor    Temperature indication   Precision     Celsius     Precision    Fahrenheit     Measurement range   Weight   External dimensions     Operating environment     Relative humidity   Storage environment   Relative humidity   Accessories     Options        With a new battery approx  5000 measurements  Thermopile   In 3 digits of    C  every 0 1  F or   C   According to NEN EN 12470  5 Clinical  thermometers     Part 5 Performance of infra red  ear thermometers  with maximum device    34  C   42 2  C   0 2  C   Based on the measurement of the standard black  body at the room temperature of 25  C  RH 50     According to NEN EN 12470  5 Clinical  thermometers     Part 5 Performance of infra red  ear thermometers  with maximum device   93 2  F     108  F   0 3  C   Based on the measurement of the standard black  body at the room temperature of 77  F  RH 50     34  C   42 2  C  93 2   108  F    Approx  50 g  1 8 02   including the battery
6. OLG dwejaue5 E          Digital Ear Thermometer    Instruction Manual  Gebrauchsanweisung  Gebruiksaanwijzing  Mode d   emploi   Manuale de instruzione  Manual de instrucciones    page  Seite  pagina  page  pagina  pagina    2 14  15 27  28 40  41 53  54 66  67 79    GentleTemp 510 English       Congratulations with purchasing the GentleTemp 510   Instant Ear Thermometer  an excellent choice  This remarkable instrument offers comfortable   safe  accurate and quick temperature measurement from the eardrum  this corresponds to the core body temperature      Please read this instruction manual first so that you can use this thermometer safely and correctly  Please retain this instruction manual for future  reference  If you have questions about the meaning of a specific temperature  please consult your doctor        TABLE OF CONTENTS    1 General 4 To interpret the measured results 10  1 1 Safety precautions 4 1 Measurement from the ear 10  1 2 Care and storage 4 2 Normal and raised temperature 10  1 3 The components of the product 4 3 Eardrum temperature compared to   2 Preparation before measurement other body temperatures 11  21 A clean probe cover 5 Troubleshooting 11  22 Move the unit in the ear 5 1 Solving problems 11  2 3 Measuring the temperature of an infant 5 2 Question and answer 12  2 4 To change the temperature from Celsius to Fahrenheit 6 Specifications 13    2 5 Recommendations  3 Usage of the GentleTemp 510    3 1 Mode 1  the fast measurement  1 3 seconds  in 7 s
7. ar the unit    e Do not disassemble  repair  or modify the unit    e The main unit is not waterproof  Be careful when handling this unit so that  no liquid  alcohol  water  or hot water  will get into the main unit     1 2 Care and storage       When the measurement is finished  clean and store the unit    Lightly wipe off any dirt from the main unit with a soft dry cloth    Never wash the unit or clean the unit with a cleaner containing an abrasive  thinner or benzene     When the infrared sensor becomes dirty  wipe it lightly with a soft dry cloth  or a cotton swab  Do not wipe the infrared  sensor with tissue paper or a paper towel     After cleaning the unit  attach the probe cover  and store the unit in the storage case    It is convenient to store the unit in the place  where you are going to use it so that you can          use it promptly  Do not store the unit in direct sunshine  where the  temperature and humidity are high  in dusty environments  near a fire   or where vibration and or shock can be applied easily     1 3 The components of the thermometer       Infrared sensor Infrared sensor    O    Probe Probe cover Probe    Button                      Display    Probe covers are consumables   If the supplied probe covers are used up  please purchase new ones     GentleTemp 510 English       2 PREPARATION BEFORE MEASUREMENT       2 1 A clean probe cover       Confirm that a clean probe cover is attached to the main unit    3  a External auditory  Replace the probe c
8. has a sharp small tip  such as a toothpick to remove the battery   Do not use metal tweezers or a screwdriver     Replace the new battery  with the plus     side on  the top     El Close the batteries cover  and tighten the screw     e     gt        To protect the environment  discard the used batteries in  accordance with the local regulations regarding waste disposal  procedure Disposal can be done at your retail store or at  appropriate collection sites     GentleTemp 510 English    4 TO INTERPRET MEASURED RESULTS    4 1 Temperature measurements taken within the ear       The GentleTemp 510   instant ear thermometer detects the infrared heat  given off by the eardrum and surrounding tissues  and it converts this heat  into an equivalent ear temperature     The GentleTemp 510  is less threatening to a child than a rectal  thermometer  It   s faster  safer and easier to use than an oral thermometer   Being digital  there s no worry about the hazard of broken glass or mercury  ingestion  Measurements can even be taken while a child is sleeping    For adults  the GentleTemp 510   Instant Ear Thermometer offers fast   convenient and accurate readings without the delay of a conventional  thermometer     Clinical research has shown that the ear is an ideal site for taking body  temperature  The eardrum shares blood vessels with the hypothalamus    the part of the brain that controls body temperature  Therefore  the ear is an  accurate indicator of internal  core  body temperature
9. he symbols on the display a Insert the probe in the ear as far  illuminate       C    flashes  as it comfortably goes in the  direction of the eardrum and  a a slightly move the unit   Ince   lt i   Leh Lee  tF  t  Wait for two beeps  El When the unit has beeped    twice  push the blue button  leaving the unit in the ear     J       GentleTemp 510 English    3 3 To measure repeatedly       3 5_ Battery replacement       Wait until      C    flashes again  after approximately 10 seconds     Continue with step 4 for  the fast measurement mode   paragraph 3 1  and for the  10 seconds measurement       mode  paragraph 3 2      ro       You can measure your temperature repeatedly up to three times   Further repeated measurements may not be possible due to the main unit  being warmed up     If you want to measure more than four times  wait for 10 minutes or longer   then start the measurement again  If the probe cover becomes dirty or    someone else uses the unit  replace the probe cover with a new one     3 4 To finish the measurement       After approximately 1 minute  the unit will be turned off automatically   The unit cannot be turned off manually even if you push the button     The GentleTemp 510   Instant Ear Thermometer detects the infra red heat  given off by the eardrum and surrounding tissues  and it converts this heat  into an equivalent oral temperature in one second     El Move the screw  and then remove the battery  cover     Remove the battery   Use something that 
10. over in the following cases   o canal   e When it is dirty  broken  or damaged   e After somebody else has used it        Slightly move the  unit inside the ear          1 Remove the probe cover  2 Attach a new probe cover        Infrared rays Eardrum    2 3 Measuring the temperature of an infant                                  Insert the probe cover Sa  until it clicks  Measuring on a lying Measuring on a sitting When the ear is too  baby  baby  small to insert the  Lightly support the Lightly support the probe   2 2 Move the unit in the ear child   s body  child   s body and While slightly pulling  Slightly pull the ear the ear towards the  To obtain a correct measurement it is important to move the unit towards the back  back  cover the external  inside the ear  auditory canal with the  probe without forcibly  trying to insert the    probe  5    GentleTemp 510 English    2 4 To change the temperature from   C to   F       2 5 Recommendations       The thermometer default is set to Celsius   C  It is possible to measure the  temperature in   C or   F  To change the unit of temperature from   C   Centigrade  to   F  Fahrenheit  follow the procedure shown below        i The GentleTemp 510   is off and the display is blank           Press and hold the blue button for approx  4 seconds   During this period all the symbols on the display illuminate        ra          Next a large C flashes on the LCD     Remove your finger from the blue button        a Each time the button is p
11. r     Correct measurement results may not be obtained    e If dirty probe covers are used    e If the ear is cold wait until the ear is warmed up before taking a  temperature measurement    e The measured result may indicate low when you use an ice bag or an ice  pack or immediately after coming in from the outside in winter    e If there is any temperature difference between the places where the unit  is stored and where you are going to measure  leave the unit in the room  where you are going to use it for more than thirty minutes to allow it to  reach room temperature first  then measure     Do not forcibly insert the probe in the ear    e If you feel discomfort such as a pain during the measurement  stop using  the unit immediately  It may injure the external auditory canal      Do not use the GentleTemp 510 6 if suffering from ear disease such as  otitis externa or otitis media  It may worsen the condition    e Do not use the unit when the external auditory canal is wet such as after  swimming or taking a bath  It may injure the external auditory canal    e Do not throw batteries into a fire  The battery may explode     GentleTemp 510 English    General Advice   e When you inform your doctor of your temperature  make sure you state  that you measured the temperature in the ear    e Do not use this unit other than for measuring the temperature in the  human ear    e Do not apply a strong shock to  drop  step on  or vibrate the main unit    e Do not use a portable phone ne
12. ressed a large C or a large F is F  displayed alternatively        B Remove your finger from the blue button        g Five   5  seconds after pressing  the thermometer turns  off automatically  The display is blank              The thermometer is now set for the Fahrenheit    F  mode  sdr          To select Celsius    C  mode  start from Step 1     Store the unit in the room where you are going to use it     If the unit has been stored in a cool  cold  room  allow it to reach ambient  temperature before using  temperature of the environment needs to be  above 10   C or keep the thermometer at least 30 minutes in the place  where you are going to use it   Do not warm the unit by placing it near a fire   Instead  place it in the room where you are going to use it to allow it to  reach the room temperature     Start measurement after the body  ear  is warmed up    The measurement may indicate a lower temperature than the actual  temperature in the following cases    e Immediately after returning to your home  especially in winter     e In a cool or cold room    e When the head  ear  is cooled by an ice bag     Confirm the measuring method by familiarizing yourself with the best way   to insert the unit in the ear  Do this during normal body temperature periods    e Note the angle you are holding the thermometer at when the highest  measurement value is indicated    e the measurement value may differ for each ear  Try to measure the  temperature using the ear that shows the highe
13. st temperature in stable  conditions     GentleTemp 510 English       3 USAGE OF THE THERMOMETER    3 1_ Mode 1  the fast measurement  1  3 seconds  in 7 steps        Insert the probe cover until E Push the blue button  After all the symbols on the El Insert the probe in the ear as far   it clicks  The thermometer is turned on  display illuminate       C    flashes  as it comfortably goes in the  direction of the eardrum and  slightly move the unit        1    En  SS  oe       w  E                          d      E L  t  When it beeps once  you can g Push the blue button leaving When the unit beeps four times   start the measurement  the unit in the ear  the measurement is finished     The measured temperature is    y shown on the display   Y       GentleTemp 510 English    3 2 Mode 2  the 10 seconds measurement in 9 steps           This function is recommended when the direction of the eardrum may be difficult to find such as measuring the temperature of an infant     E Insert the probe cover until Push the blue button     it clicks  The thermometer is turned on        Do not press the blue button if g Slightly move the GentleTemp    the beep sounds only one time  510    while the unit tries to  The measurement will start detect the temperature of the  automatically  eardrum for a maximum of    10 seconds        El When the unit beeps four times   the measurement is finished   The highest measured tempera   ture is shown on the display                             After all t
14. sured result is  below 34  C  93 2  F    the measurement  was finished           L t       Did you remove the  thermometer before    Remove the thermo   meter from the ear  after the measurement  is finished        The measured result Is the infrared  exceeds 42 2  C  108 0  F     sensor broken        Return to the selling  point        1 t                Is the probe  cover broken        Replace the probe  cover with a new one        The temperature of the  main unit may be below  10  C  50  F      om  iL    correctly when the  temperature of the             ranges           The temperature of the  main unit may be above  40  C  104  F      Ai                   12    You cannot measure    main unit is in these       Measure the temperature  after leaving the unit in  the room where you are  going to measure so  that the unit is accus   tomed to the tempe   rature of that room   between 10  C   40  C   50  F   104  F     If you store the unit   in the room where you  are actually going to  measure  you can  measure quickly                             If the    Er 1    is Wait for the unit to  E 1  displayed again  turn off  then turn on  EP  1 the unit may the unit again    be faulty    This occurs when the device is moved from   one space to another and the difference in   temperature is more than 10  C  Wait for at   pa least five minutes until    AA    mark is not   on    we displayed anymore              5 2 Question and answer    Might be caused when the probe is grasped
15. teps  3 2 Mode 2  the 10 seconds measurement in 9 steps  3 3 To measure repeatedly  3 4 To finish the measurement  3 5 Battery replacement    0000 Y  0000000420    GentleTemp 510 English    1 GENERAL    1 1 Safety precautions       Warning   Conducting self diagnosis based on the measurement results and or  treatment can be dangerous  Please follow the instructions of your doctor   Self diagnosis may worsen the symptoms     Do not touch the infrared sensor with a finger or breathe on it    e The infrared sensor may become dirty and the correct measurement result  may not be obtained    e If the infrared sensor becomes dirty  lightly wipe it with a soft dry cloth    e If you wipe it with a tissue paper or a paper towel  the infrared sensor will  be damaged and may not be able to measure correctly     Only use probe covers that are especially designed for this unit    e Do not use a probe cover after someone else has used it  This can lead to  cross infections such as otitis externa    e If the probe cover becomes dirty with earwax or other substances   replace it with a new one    e Correct measurement result may not be obtained if dirty probe covers  are used        Store the unit out of children   s reach    result may not be obtained if dirty probe covers are used  Store the unit out  of children   s reach  Children may try to measure by themselves and may  damage the ear  In an emergency case if a child swallows a battery or a  probe cover  immediately consult with a docto
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
SV7220-2A BIOS User Manual  DSC-F717  Yamaha DVD-S795 Operating Instructions  Audio Research REFERENCE 150  le chemin desÉtoiles  Avaya B5800 Release Notes  GV-Hot Swap DVR System V5    Copyright © All rights reserved. 
   Failed to retrieve file