Cerberus CerGas Software tool SWE60 User manual

image

Contents

1. General Control unit File Edit Parameters for a new system are set under File New All directories on the diskette previously pro duced using the SWUDSK program are listed in the file selector box The directory in which the in stallation data is to be stored must first be selected The system number without an extension must then be entered in the input window The control unit number is then the name of the file in which the system data is stored 11 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 The following input screen appears once a file has been opened General Control unit File Edit OPEN FILE The missing data must now be added and the window closed by pressing lt Enter gt with the cursor on the OK button 3 5 2 Open General Control unit File Edit SAVE FILE An existing system is opened under Open The directories present on the system diskette are listed in the file selector box When the directory to be used has been selected the existing systems control unit numbers are listed The system is opened by selecting the Open button and confirming with lt Enter gt Note opening a system can take up to 5 minutes 12 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 5 3 Save General Control unit File Edit PRINT OUT Systen no A Date 2770471998 Control unit DEHO Type List to Docunent X Printer Parts List
2. e1369e 10 2002 3 5 6 Delete General Control unit File Edit DELETE FILE DK lt CANCEL gt Existing systems can be can be deleted with function Delete You must first select the appropriate di rectory before a system can be deleted The relevant control unit number can be selected within the directory and deleted by confirming the Open button by pressing lt Enter gt 15 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 6 Menu Edit General Control unit File Edit Control Zones A gas detection system is actually configured in the menu Edit This menu will not be active unless a new system first has been created or an existing system has been 3 6 1 Operation General A parameter must be selected using the lt Tab key gt if you wish to edit it lt Shift gt and lt Tab gt takes you back one parameter Within an editable parameter you can use the lt Cursor keys gt to select the setting desired which you can then confirm with the lt Spacebar gt The confirmation is indicated by a point next to the setting selected Where a number of settings are possible for a parameter but not listed on the screen an appropriate selection can be displayed by pressing the lt Spacebar gt 16 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 6 2 System parameters All control unit specific system data and all system times are configured under
3. 24 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 ENABLE blocked can be used to lock the selected detector out Caution A detector must be set to Lock No for it to function With Sensitivity you can define the value in of the calibration value below which a detector is considered to be outside the tolerance during the test using calibration gas and is recorded as too in sensitive Important It must not be changed Init commissioning and Next change are entry of the corresponding data The periodicity of sensor change can be found in the maintenance documentation Last calibration can not be changed 3 6 6 5 Inversion of alarms General Control unit File Edit INVERSION OF ALARMS Type normal Normal Inverse J Printer DHS Fault Xx x Warning 1 x1 Prealarn x Alarm X Xx FE 101 lt lt CANCEL gt This menu defines whether a detector is to be operated in the inverse e g O2 You can also define which event levels are to be transmitted to the printer or to the DMS Make the selection by pressing the lt Spacebar gt 25 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 6 6 6 Alarm release FA WA PA AL General Control unit File Edit ALARH RELEASE FAULT WARNING PREALARH ALARH FE 101 lt This function is used to enable or block the Fault Warning Pre alarm and Alarm event levels for e
4. Fire amp Security Products 10 2002 3 6 2 1 System times 18 General Control unit File Edit SYSTEM TIHES Systen tines Change time Day Night HH MM Date 27 04 1996 ist time 17 30 4th tine 24 00 Time 09 07 2nd tine 24 00 Sth tine 24 00 Con dat 27 04 1998 3rd tine 24 00 Aut det DN chang NIGHT Switchover dates Switchover dates Sunner Winter D N Y Winter Sumner Df H Y1 CAK Delay times 1st date 21 09 1995 1st date 21 03 1995 Invest time Wi sl 2nd date 21 09 1996 nd date 2170371996 Invest time U2 s 3rd date 21 09 1997 3rd date 21 03 1997 Warn exp U2 s 4th date 21 09 1998 4th date 21 03 1998 Ren aud sig sl sth date 21 09 1999 sth date 21 03 1999 Hains fail delay O sec Tine dat check 10 00 CHH HH systime System times is used to set the current date the time of day and the date of commissioning in the control unit The Change time Day Night define when the switch over from day to night operation CAK is to take place With Aut det ON chang Night is possible to configure whether detectors that have switched off are to be switched on automatically during the switch over from day to night Note never switch on detectors automatically The Switch over dates define the Summer Winter and the Winter Summer switchover times At least one switchover data must be defined for each occasion otherwise a fault will be signaled on the control unit The Cerberus Alarm Concept is set up using the CAK Del
5. lt CANCEL gt The system currently open is saved to disk with Save The directories present on the system diskette are listed in the file selector box Once the directory has been selected the configuration must be sto red under the same file name control unit number as it was opened Caution it s forbidden to use file names with special signs like 3 5 4 Convert This function is not yet implemented 13 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 5 5 Create list A listing for the system currently opened may be created using this function General Control unit Open Save Convert Create List Delete Itis only necessary to check the menu File if you wish only to create a data file The Printer func tion must also be checked if you wish to print the system data Caution menu General Control unit File Edit System no A Control unit DEMO Type List Document Cx Parts List 1 PRINT OUT 27704 19986 to Printer lt CANCEL gt The window illustrated below only appears if you are printing via the serial port CWPrint V2 0 5495 DEVICE Parallel PRN Seriell COW1 Seriell COHN2 Netz LPT2 3 14 Fal UCTU Zeichensatz IBM Zeichensatz ASCII Zeichen No listing can be created if no port has been selected for the printer under the General Siemens Building Technologies Fire amp Security Products
6. Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 6 7 Copy function The Copy function function does not become active until all detector parameters have been de fined General Control unit File Edit DETECTOR COPY FUNCTION MASTER DETECTOR FE 101 Fron FE 101 FE1B1 lt lt CANCEL gt All detector parameters with the exception of the Assignment of the physical detector address to the logical FE address can be copied with the copy function Nor can the calibration data of the detectors be copied Zone parameters and assignments cannot be copied Copy procedure Select the Master detector with the lt Tab key gt and specify the appropriate completely configured Master detector Then use the lt Tab key gt again to select the From FE To FE function where you will have to enter the FE addresses of the detectors into which the master data are to be imported The copy function is executed when the OK field is selected and confirmed with lt Enter gt Caution Detector parameters that have already been configured will be overwritten by the copy function 29 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 6 8 Control zones The function Control zones does not become active until the detector parameters have been de fined General Control unit File Edit ZONES CONFIGURATION DETECTOR ASSIGNHENT RELAY ASSIGNMENT ON OFF DELAY lt Edi
7. Spacebar gt to define the zones or Relay capability 3 Pressing the lt Tab key gt again takes you to the Relay field in which the relay desired can be as signed to the selected group with the Cursor keys 4 Press the lt Tab key gt to select the Assignment field and confirm by pressing lt Enter gt Relay as sociations can be seen in the Assignments field Comment The assignment of zone to relay must be defined separately for each 3 and 4 must be repeated as many times as there are relays in a zone 32 relay i e steps Siemens Building Technologies Fire 8 Security Products e1369e 10 2002 3 6 8 3 On Off delay General Control unit File Edit ONES DELAY TIMES OnvA OffWA OnPA OffPA OnAL Of FAL 0 0 0 0 0 a Alarms Hin 10 1 ON Delay WA 0 ON Delay PA 0 ON Delay AL 0 OFF Delay WA 0 OFF Delay PA 0 OFF Delay AL 0 20 1 lt Ok gt lt CANCEL gt The on and off delays per zone and per event level are defined in this function The lt Cursor keys gt are used to select the control zone control zone to be configured from the Zone field Pressing the lt Tab key gt takes the cursor to the selector box in which the times desired can be ente red in 6 second increment Once all times have been defined the OK field can be selected with the lt Tab key gt and the para meters accepted by pressing lt Enter gt The energizing delay times and release delay times are shown in the upper se
8. actual site drive 7 directory A start use key lt Ins gt Cor mouse to pull down menus End use command EXIT in MENU General to return quit Version 1 3 of 19 HNarch 97 The opening screen is displayed when the SWE60 system editor is started It includes all the instructi ons necessary for the functions of the SWE60 system editor These include e g the presence of the dongle M3C060 in the parallel port the installation diskette in drive A etc Siemens Building Technologies Fire 8 Security Products e1369e 10 2002 3 SWE60 system editor functions 3 1 General and Operation Press the lt F10 gt function key or the key combination lt Alt gt and lt hotkey gt to open a dropdown menu A menu item in a dropdown menu may be selected with the lt up down arrow key gt and opened with the lt Spacebar gt or the lt Enter gt key The parameters within a menu item available for editing may be selected with the lt tab key gt The edited data can be accepted by selecting the OK button and pressing the lt Spacebar gt or lt Enter gt To discard the parameters select the CANCEL button and press the lt Spacebar gt or lt Enter gt 3 2 SWE system editor menu interface General Control unit File Edit When the system editor is started a menu bar with the options General Control unit File and Edit is displayed The Edit option can only be activated after opening a new or existing system The function
9. follows 1 The appropriate FE address is first selected using the lt Cursor keys gt 2 Change to the selector box showing the Analogue outputs available using the lt Tab key gt then select the analogue output desired using the cursor keys 3 The Start value and End value of the analogue output can be edited by pressing the lt Tab key gt again 4 The resolution can thus be changed as for the bar display The function is saved by selecting the OK button and confirming with lt Enter gt 27 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 6 6 9 Calibration gas concentration General Control unit File Edit DETECTOR PARAMETERS ASSIGNMENT CONFIGURATION RETENTION CALIBRATION GAS Pos ZERO CAL GAS FE101 a 100 This function defines the concentration of the Zero gas purge and the concentration of the Cal Gas calibration gas bottle for each sensor 3 6 6 10 Set threshold values WA PA AL General Control unit File Edit DETECTOR PARAMETERS ASSIGNMENT CONFIGURATION RETENTION THRESHOLD VALUES Warning Prealarn Alarm FE 181 lt Ok The threshold values event levels for each detector are defined using this function The following threshold values can be defined for each detector Warning WA Prealarm PA Alarm AL Recommendations for the threshold values can be found in the maintenance documentation 28
10. to position S down 2 Configuration of the CC60 control unit for data backup 1 Release operation password 7000 2 F4 040 Service PC ON 3 F4 045 baud rate 9600 9 Siemens Building Technologies e1369e Fire 8 Security Products 10 2002 3 4 2 Data transfer SWE gt CC Data is transferred between the PC and the control unit to load control unit parameterization which has been configured on the PC To carry out control unit parameterization you use first the selector box select the file in the appro priate directory in which the control unit data are stored Caution Any existing control unit parameters will be overwritten when a control unit is configured through the PC General Control unit File Edit TRANSFER SWEGO gt gt CCOO lt CANCEL The remainder of the procedure is analogous to data backup subclass 3 3 1 3 4 3 Software update This function is not yet implemented 10 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 5 Menu File General Control unit File Edit Neu Open Save Convert Create List Delete In the File menu parameters are set for new systems under New existing systems are edited un der Open the data are saved to disk under Save existing system parameters converted to a hig her software version under Convert the system parameters are printed out under Create list and existing systems deleted under Delete 3 5 1 New
11. ALLY REMOTE Note The Detector lines function is used to define the gas detector lines This may be either a stub line or a loop line In addition you are able to define whether the detectors are fed from the control unit or whether the detectors are supplied from outside Detection lines Parameterization is carried out as follows 1 The lt Cursor keys gt are used to select the line interface to be configured this is confirmed with the lt Spacebar gt 2 Use the lt Tab key gt to select the selector box showing the possible line types Then you can se lect the line type required with the lt Cursor keys gt and confirm your choice with lt Enter gt 21 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 6 6 Detector parameters General Control unit File Edit DETECTOR PARAMETERS ASSIGNMENT CONFIGURATION RETENTION DETECTOR 7 FE BAR DISPLAY OF THE DISPLAY lt Edit gt lt Edit gt lt Edit gt GENERAL INVERSION RELEASE DETECTORS CONFIGURATION OF ALARMS CFASWA UAZAL lt Edit gt lt Edit gt lt Edit gt SENSOR TYPE CONFIGURATION CONCENTRATION ANALOG OUTPUTS CALIBRATION GAS lt Edit gt lt Edit gt lt Edit gt THRESHOLD VALUES SET CWA UA AL lt CONTINUE gt lt Edit gt Note All detector specific parameters are defined under this function The menu is used as follows Use the lt Tab key gt to select the field you wish to configure Confirming by pressing lt Ent
12. OAS LE EAA AE AL rra 5 3 2 SWE SYSTEM EDITOR MENU INTERFACE veiei t aer iriin ss antas Eriin PATA AAE PARLERAI ATAA AAKER PAARE ARTEA 5 3 3 IMENUSGENERAL ne a a A eden EAE AEAEE A EEA AREARE AAS EA ARAA 6 3 3 1 A NS 6 3 3 2 A O NO 7 SA MENU CONTROL UNIT osred iea na da ARIER 8 3 4 1 Data transfer CC gt SWE ala an Arne ine a dat dad L I ea iaar EaR 8 3 4 2 Data transfer SWE gt GE 2 ia 10 3 4 3 E AN 10 3 97 MENU E a 11 3 5 1 NW A a Rad 11 3 5 2 A a e a a a AO 12 3 5 3 SAVE a Ban ar Petes Er e 13 3 5 4 CONVE Me ee E ede e lee ee 13 3 5 5 Create A hae eA eect a aaa 14 3 5 6 Delta a Oe ance rr eo re eee as 15 30 MENU EDIT an 16 3 6 1 Op ration General 2 fs A 16 3 6 2 System parameters nn li asien anna need 17 3 6 21 System times isn na eddie 18 3 6 3 Hardware tn een add all onde eee tated 19 3 6 4 Interfaces cui Bee ae I ane ibe ee A ne dee 20 3 6 5 Detection NINOS cocina A ea ayia dees A taa 21 3 6 6 Detect rparamelers 0 2 2 een di ai 22 3 6 6 1 ASSIGNMENT DETECTOR FE ersnneeensnnennnennnnnnnnnnnnnnnnnnnnnnnennnnnsnennnnnnnnnnnnnnsnennnnnsnnnn nenn 22 3 6 6 2 Bar display CONfiguUratiON oooonnnnnccnnnnccccnnnocccnn conc ccnnnorc cnn nar c cnn rra 23 3 6 6 3 Alarm hold elle 24 3 6 6 4 General configuration nina nnd nannten nn 24 3 6 6 5 Inversion of alarmsS 44 n0u es een ann ae dd cda baaa 25 3 6 6 6 Alarm release FA WA PAJAL 2 u222s2nnsnnsnennennsennnnnn
13. ODEM AT CABLE 427667 AT cable 9f 25m L 0 25m 417279 Cable 25f 25m L 2m Ribbon 466453 AT modem cable 25m 9f L 4 5m 433842 MONITOR CABLE 9f 9m L 3m 1 5 Starting SWE 60 The program is always started from the CS menu shell SWE The program is started using the command SWE60 Cerberus specification batch file The program will not run unless the dongle M3 C060 CC60 462 075 CS specified is connected to the computer s printer port 1 6 Operation The program is operated through the keyboard using hotkeys function keys and the tab key The program optionally supports a mouse on the serial ports COM1 or COM2 The dialogue language is the national language of the installation country this can be selected in a configuration file See the Cerberus guidelines and the operating element listed in the documents PC Setup Installati on Operation e996a and SWUDSK e969a for further operations Documentation in SWTS 60 file 2 Siemens Building Technologies Fire 8 Security Products e1369e 10 2002 2 Starting SWE60 menu shell 2 1 Opening screen The opening screen appears once the SWE6O0 tool is started from the Cerberus menu shell The dropdown menus can be opened using the lt Ins gt key Vindous Allgemein Site Disk System Editor CERBERUS Command Shell Danger detection control unit CC60 actual site drive Y directory A Start use key lt Ins gt Cor mouse to pull down menus End use command EXIT
14. SIEMENS Cerberus CerGas Software tool SWE60 User manual Fire Security Products Siemens Building Technologies Data and design subject to change without notice Supply subject to availability O Copyright by Siemens Building Technologies AG We reserve all rights in this document and in the subject thereof By accep tance of the document the recipient acknowledges these rights and un dertakes not to publish the document nor the subject thereof in full or in part nor to make them available to any third party without our prior ex press written authorization nor to use it for any purpose other than for which it was delivered to him 1 o o cisticaceassd caienscinanecsansaasnstisinssaststasseiuauash anda beasdisaaansendudoas al anaa TEASA EAn Eai ata anarika aapt 1 isk PURPOSE rnr OE A E R A E 1 122 USERINTERRACE ae Rue A EOE A REE EA 1 EI USER PRO E radio 1 1 4 SYSTEM REQUIREMENTS cotas 2 1 4 1 Ordering information ici 2 1 9 STARTING OWE DU nn at eure dia 2 EG OPERATIONS A A Ea 2 2 STARTING SWE60 MENU SHELL ia 3 21 OPENING SCREEN comicidad eai ii a iea dt d ia dd 3 2 2 MENU GENERAL vi nendra eri Rn aa doaeh budaatayl He E 3 2 3 MENU SYSTEM DISK anna nr nie eins a it einen 4 2 4 SWE 60 SYSTEM EDITOR nr hr need rue 4 3 SWE60 SYSTEM EDITOR FUNCTIONS uusrzesnanennennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnsnnnnnnn anne 5 3 1 GENERAL AND OPERATION aesaat E
15. System parameters General Control unit File Edit SYSTEH DATA Language selection Mains freq Hat language 5OHz English 0 60Hz J J Passuord Level 6 70001 7001 70021 Validity Level 1 7100 7101 7102 Validity Level 2 72001 72011 72021 Validity UDGO Query withou passu Ye Ho Access authoriz F1 F2 LEVEL 0 lt SYSTEM TIMES gt lt CANCEL gt Language selection This can be used to select the language to be used when working with the control unit You always have the option of selecting between the Default language of English and the national language stored in the text EPROM in the control unit Mains freq Setting the mains frequency according to national mains ratings Password The control unit has three levels of hierarchy each with three individually editable passwords Level O Service engineer Level 1 Unrestricted authority Level 2 Restricted authority It is also possible to specify the duration of the release 4 99 min or 999 for infinite VD60 Query without passw This can be used to select whether the control unit parameters should be visible for viewing on the control unit display VD60 or not without entering a password Access authoriz F1 F2 is used to define from which password hierarchy on the control unit de tector on off and detector test can be released Recommended User with all rights 17 Siemens Building Technologies e1369e
16. Yes 19 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 6 4 Interfaces General Control unit File Edit INTERFACES SU service PC Remote display On On 1 off C Off Baudrate 9600 Baudrate Printer Management Systen HOT CONNECTED NOT CONNECTED Location Adr 0 Baudrate 2400 Baudrate _ 30 2400 lt CANCEL gt The Interfaces function defines the interfaces on SU 60 Service PC function specifies whether the Service PC interface is to be active or inactive You also define the corresponding transmission rate which must be identical on the PC and the control unit A selection box can be opened by pressing lt Space gt Remote display function is used to indicate whether further terminals CT 60 are connected to the control unit not currently available The Printer function is used to specify whether a Cerberus printer a third party printer or no printer is connected to the control unit A selection box can be opened by pressing lt Space gt With the Management system function is the same way as for the printer you can define whether the control unit is to communicate with a management system A selection box can be opened by pressing lt Space gt 20 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 6 5 Detection lines General Control unit File Edit DETECTOR LINES Detector LOOP LOCALLY LOCALLY gt LOC
17. ach detector The selection is made with the lt Spacebar gt Note Enable all event levels Reporting of events can be suppressed in the zone definition if it is not required 3 6 6 7 Sensor type General Control unit File Edit DETECTOR PARAHETERS ASSTGNHENT CONFIGURATION RETENTION SENSOR TYPE FE101 Sensor types FE 101 GSP68 01 Horn GSE60 06 H0 GSE60 O2 CO GSE60 O7 CL2 GSE60 O8CNO2 GSE60 14 03 GSE60 13CETO GSE60 11 NH3 GSP60 01 Horn GSP60 02 Lead GSP60 03 Spec Sensor type is used to assign an application specific sensor type to the detector The FE address required is first selected using the lt Arrow keys gt Select the sensor selector box with the lt Tab key gt then select the Sensor type required with the lt Cursor keys gt The selection must then be confirmed with lt Enter gt The relevant sensor is shown next to the FE address 26 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 6 6 8 Analogue outputs configuration General Control unit File Edit DETECTOR PARAMETERS ANALOG OUTPUT ASSIGNMENT AK6O Start End AK60 output 0 0 Position AK6O Start value End value A A A A A A A A Note The Analogue outputs function is only enabled if an analogue card AK60 has been defined in the function Hardware see 3 6 3 An analogue output 4 20 mA can then be assigned to each detector Parameterization operates as
18. ay times With Mains fail delay the event of mains failure can be edited 0 10000 sec The Time dat Check specifies when any check on switch over times has to be carried out Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 6 3 Hardware General Control unit File Edit HARDWARE DEFINITION BUS slots Front elements Keyb f fire stat AKGO lt CANCEL gt E46030 E46040 Note Hardware specifies the hardware configuration to the control unit The Bus slots is used to configure the plug in cards plugged into the sub rack bus G3E010 Pa rameterization must be carried out as follows 1 The lt Cursor keys gt are used to select the BUS number to be configured this is confirmed with the lt Spacebar gt 2 Use the lt Tab key gt to select the selector box showing the possible cards Then you can select the card required with the lt Cursor keys gt and confirm your choice with lt Enter gt The Front elements specifies to the control unit how many FE 60 are located on the control unit Later in the assignment of the physical to the logical detector address only those logical addresses will be released that have been selected with the display elements The Keyb for fire stat indicates whether a fire department control panel is fitted in the control unit Note The E4G030 controller cards are automatically set on bus no 18 and 19 if fire department control panel is set
19. e to the CS standard MODULA 2 mode interface Thus the tool is defined to be usable with an SAA window oriented user interface Deviations from standard CS operation are described in this user manual The user interface has been developed to allow extremely simple language adaptations 1 3 User profile The user group is defined as consisting of the service engineers project members and construction site supervisors The user interface has thus been defined according to the CS standard The project member and construction site supervisor will typically use the tool in the office to pre program a gas detection system The service engineer will typically use the tool on the customer s site for servicing and commissioning work on gas detection systems 1 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 1 4 System requirements The tool requires the following platform as a minimum configuration Computer IBM AT or compatible Operating system MS DOS PC DOS v6 2x RAM at least 550 KB free memory EM 368 exe gt disabled Smart drive gt disabled Mass storage HD FD Screen CGA EGA VGA Keyboard PC XT AT mouse optional Interfaces 1 x RS232 1 Centronics Copy protection protected by dongle on LPT1 Accessory B3D021 modem with data cable 1 4 1 Ordering information Item Part no Designation SWE 60 01 gt OSS Parameter editor for SWE 60 M3C 060 462088 DONGLE D FULL B3D 021 505259 V24 DUAL M
20. er gt then ta kes you to the relevant submenu Recommendation Parameterization must be carried out in sequence first from left to right and then from top to bottom 3 6 6 1 ASSIGNMENT DETECTOR FE General Control unit File Edit 9 13 21 DETECTOR PARAMETERS ASSIGNHENT DETECTORS Z FE Detector position Det nunber phys lt lt Assign lt lt gt Renove gt gt lt CANCEL gt ASSIGNMENT DETECTOR FE is for the assignment of a physical detector address to a logical address on the FE 60 display Select with the lt Cursor keys gt the detector position which a physical detector address is to be as signed After them you must use the lt Tab key gt to switch to the Detector number phys selector box 22 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 Use the lt Cursor keys gt to select the physical detector address required Pressing the lt Tab key gt again selects the Assign field and the function is concluded by pressing lt Enter gt The assignment is now indicated at the detector position An assignment is deleted in exactly the same way except that the Remove field is selected instead 3 6 6 2 Bar display configuration General Control unit File Edit DETECTOR PARAMETERS ASSIGNHENT CONFIGURATION RETENTION BAR DISPLAY CONFIGURATION Stat Start End FE181 norm 0 7 100 Normal Inyerse Start val 0 End value 100 FE 101 lt Ok
21. he detector which is to be assigned to the zone 4 Press the lt Tab key gt to select the Assign field and confirm by pressing lt Enter gt Assignment to a zone is indicated in the Assign field Note If the Splitting Flag has been released in the CC60 you can shift to the Zone capability using the lt Tab key gt The lt Cursor keys gt and the lt Spacebar gt can then be used to define the zone capability The assignment of detectors to a zone must be defined separately for each detector i e steps 3 and 4 must be repeated as many times as there are detectors ina zone 31 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 6 8 2 Relay assignment General Control unit File Edit ONES RELAY ASSIGNMENT cone capability Relay messag Relay 1 WPAA Warning Prealarm XI Alarm 1 Assignments 0 01 REL 1201 1201 PA lt lt Assignment lt lt gt gt Remove gt gt g rel Relays located on relay cards on the control unit BUS can be assigned to the processes of defined control zones using the function Relay assignment Itis only possible to assign relays which have been defined under the function Hardware see 3 6 3 Parameterization is carried out as follows 1 Use the lt Cursor keys gt to select the zone number to be configured 2 Use lt Tab key gt to switch to the Zone capability field Then you can use the lt Cursor keys gt and the lt
22. ile Edit Data transfer CC gt SWE Data transfer SWE gt CC SW Update The Control unit menu is used for communication with the CC60 control unit Communication can ta ke place in both directions Data can be transmitted from the control unit to the PC and vice versa Data transfer CC gt SWE Data is transferred from the control unit to the PC to back up the data on the system In order to carry out the backup procedure you must first use the selector box to specify the file in the appropriate di rectory in which the control unit data will be saved General Control unit File Edit TRANSFER CC60 gt gt SWEGO lt CANCEL Note If you choose an existing file the existing parameters will be overwritten Siemens Building Technologies Fire amp Security Products e1369e 10 2002 Once you have selected the file and confirmed with lt Enter gt you are automatically to the port definiti on In this function you must select the serial port Com no and specify the Baud rate on the PC General Control unit File Edit SERIAL PORT COM no 1 Baud rate 9600 Note A percentage bar representing the data transfer will appear on screen if the communication between the control unit and the PC is in order Requirement for data transmission 1 PC connection for data backup CC60 M3C060 Parallelport RS232C Com1 Note If the B3D021 modem is used Input A1 A2 Output K1 K2 Switch S1 S2
23. in MENU General to returnsquit Version 1 3 of 19 March 97 2 2 Menu General An information box can be opened under the General menu The User Manual is opened under Manual SWE60 is also closed by selecting End in this menu Allgemein Info Handbuch CERBERUS Command Shell Danger detection control unit CC66 actual site drive Y directory A Start use key lt Ins gt Cor mouse to pull down menus End use command EXIT in MENU General to return quit Version 1 3 of 19 March 97 3 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 2 3 2 4 4 Menu System Disk Windows Allgemein Site Disk System Editor Prepare site disk Start SWUDSK Directory of disk List all files Hake a copy of disk Format disk 720KB CERBERUS Command Shell Danger detection control unit CC60 actual site drive directory A start use key lt Ins gt Cor mouse to pull down menus End use command EXIT in MENU General to return quit Version 1 3 of 19 March 97 A system disk must first be created using the SWUDSK program before the SWE60 system editor can be started The functions of the SWUDSK program are described in document SWUDSK e969a SWE 60 system editor Windows Allgemein Site Disk System Editor System Editor SWE60 Start Editor SWE60 Up and Download Utility CC60 Start CC 66 CERBERUS Command Shell Danger detection control unit CC60
24. l zone which is to be configured Pressing the lt Tab key gt changes to the Configuration field where the criterion required can be spe cified by pressing the lt Spacebar gt The definition is saved by pressing lt Enter gt with the cursor in the OK field Parameterization must be carried out separately for each control zone PRT Printer DMS Management system None No output Important every control zone used must be set to Active Yes in the Configuration field otherwise the control zone has no function There must be at least 1 zone with all detectors so that the relays on the SU60 become active in the event of a WA PA AL activity 35 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 Siemens Building Technologies AG Alte Landstrasse 411 CH 8708 M nnedorf Tel 41 1 922 61 11 Fax 41 1 922 64 50 www cerberus ch Document no e1369e Edition 10 2002 Manual CG60 Section 6
25. lector box The times must be defined separately for each zone 33 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 6 8 4 Alarm hold General Control unit File Edit ZONES SELF HOLD self hold Warning Prealarm Alarm lt CANCEL gt The holds for the zones are configured in this menu It is possible to specify for each zone whether Warning Pre alarm and Alarm are self holding or automatically resetting once the value has fallen below a relevant threshold value The control zone which is to be configured is selected in the Zone field using the lt Cursor keys gt Pressing the lt Tab key gt changes into the Self hold field where the hold at each threshold value can be configured by pressing the lt Spacebar gt The definition is stored by pressing lt Enter gt when the cur sor is in the OK field 34 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 6 8 5 Zone activity Alarm outputs General Control unit File Edit ZONES ACTIVITY ALARH ones WA PA AL ACT Configuration eD 1 OD D H Warning Prealarn PRT 1 PRT 1 DHS X DHS X NONE 1 NONE J Alarm PRT zone active lt CANCEL gt This function is used to specify where the zone and relay messages are to be sent You may choose between no output message message to the printer and message to DMS Use the lt Cursor keys gt to select from the Zone field the contro
26. lt CANCEL gt Bar display configuration is used to define the resolution of the concentration indicator on the FE 60 for each gas detector The resolution can be increased or reduced with a start value and end value This is done by first se lecting the FE address desired in the selector box The bar display can also be set up to the inverse This is useful if a purge process e g O2 is to be displayed 23 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 6 6 3 Alarm hold General Control unit File Edit DISPLAY RETENTION Fault self hold Warning self hold Prealarm self hold Alarm self hold FE 101 lt The Retention of the Display function is used to program whether the indication on the FE display is to be holding not holding for each event level and detector The following event levels for each detector can be programmed as holding or nat holding Faults FA Warning WA Prealarm PA Alarm AL Caution Hold relates only to the display and has no impact on the relay controllers 3 6 6 4 General configuration General Control unit File Edit GENERAL DETECTOR CONFIGURATIO Pos Configuration FE 101 enabled ENABLE blocked Sensitivity 707 Init comnissioning 27 04 1998 Next change Ef Last calibration Of FE 101 lt lt CANCEL gt The General configuration function is used to define the calibration parameters for the gas detec tors
27. nnennnnnnnnnnnnnnnannnnnnnennnnnnnennnnnnnennnnn nennen nn 26 IS A O 26 3 6 6 8 Analogue outputs configuration oon ooccnnnnnccnnnnococcnnnonccnnnnorccnnnnorc carr nrn cnn narrar rra 27 3 6 6 9 Calibration gas concentration sso keare e E nono EEE EEE E E EE EER 28 3 6 6 10 Set threshold values WA PA AL 00occcnnnncccnnnoccccnnnoccccnnnonncnnn non carr nn cnn rca rr 28 3 6 7 Copy TUNC IOM 2 a ica 29 3 6 8 GOntrOl ZONES taa A A nern ie antenne a 30 3 60 91 Deteclor ssignment n nu ia tea teureren 31 3 6 8 2 Relay ASSIM italian 32 3 6 8 3 On gt OTT delay ii 33 30 04 Alarm holde ridad 34 3 6 8 5 Zone activity Alarm OPUS e n E E src 35 l Siemens Building Technologies 10 2002 Fire amp Security Products Modifications Version Date Description e1369c 04 2000 SIEMENS layout new Section 1 4 Ordering information modified e1369d 08 2002 Information about saving e1369e 10 2002 Design Siemens Building Technologies Fire 8 Security Products e1369e 10 2002 1 Introduction 1 1 Purpose SWE 60 is an application which runs on the CW 1100 03 Cerberus Service tool notebook laptop The tool supports configuration and parameterization and also data backup for the CC 60 gas detec tion system control unit The program is largely linked into the existing CS menu shell SWE menu and has been adapted to this specification 1 2 User interface The user interface is adapted as far as possibl
28. s for the various options are described below 5 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 3 Menu General General Control unit File Edit About Setup Quit ALT Q This menu includes the functions About for the SWE60 system editor Setup and Quit which you can use to leave the system editor 3 3 1 Setup Use the Setup function to change the screen from monochrome to color display Any printer port will be configured here General Control unit File Edit About Setup Display Mono Display Colour Quit ALT A Printer 6 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 3 2 Printer The parallel or serial port is configured under the function Selection General Control unit File Edit About Setup Display Hono Display Colour Quit ALT A Printer Selection Setup Printer The port can be selected under the function Port General Control unit File Edit SELECT PRINTER Printer Port EPSON compatible LPT 1 3 CERBERUS serial lt CANCEL gt The port desired can be selected using the lt cursor keys gt and confirmed with the lt Tab key gt by selecting OK Note The printer driver CWPRINT EXE which is located in c swe60 sys will be used for printing 7 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 4 3 4 1 8 Menu Control unit General Control unit F
29. t gt lt Edit gt lt Edit gt ALARM HOLD ZONE ACTIVITY ALARM OUTPUT lt Edit gt lt Edit gt lt CONTINUE gt All detector zone specific parameters are defined under the function Control zones The menu is used as follows Use the lt Tab key gt to select the field you wish to configure Then confirming by pressing lt Enter gt takes you to the corresponding submenu Note Parameterization must be carried out in sequence i e first from left to right and then from top to bottom 30 Siemens Building Technologies e1369e Fire amp Security Products 10 2002 3 6 8 1 Detector assignment General Control unit File Edit ZONES DETECTOR ASSIGNMENT Zone capability Associations Warning Warning Prealarm Alarm Prealarm All Alarn Assignments cO 101 lt lt Assign lt lt gt gt Renove lt CANCEL gt The individual detectors are assigned to the control zones under detector assignment Parameterization is carried out as follows 1 Use the lt Cursor keys gt to select the zone number to be configured 2 Pressing the lt Tab key gt again takes you to the Associations field in which the number of detectors which must reach the corresponding threshold value for the corresponding zo ne activity must be entered Caution At least 1 must be entered to allow a zone to be activated 3 The lt Tab key gt is pressed again to select the Items field where the lt Cursor keys gt can be used to select t