Contents

1. CONNECT EQUIPMENT TO UPS Now connect your lour load to be protected computer monitor etc to the AC Output receptacles at the rear of the UPS Reference the figure 4 HU Figure 4 Enable the UPS by turning on the Power ON OFF switch which is situated on the front panel The UPS is now ready to use Switch on your equipment BATTERY MAINTENANCE BATTERY CHARGING AFTER SHIPMENT FROM THE FACTORY THE BATTERY WILL NEED A FULL RECHARGING OF AT LEAST 12 HOURS IF NOT USED FOR A LONG PERIOD OF TIME THE BATTERY WILL START SELF DISCHARGING WHICH MAY RESULT IN A SHORTER SERVICE LIFE OF THE BATTERY OR MAY EVEN CAUSE DAMAGE TO IT DURING THE WARRANTY PERIOD CARE SHOULD BE TAKEN TO AVOID EXCESSIVE TEMPERATURE AROUND THE UPS WHICH COULD ALSO RESULT IN REDUCING SERVICE LIFE OF THE BATTERY TO ACHIEVE MAXIMUM SERVICE LIFE FROM THE BATTERY THE ABOVE INSTRUCTIONS SHOULD BE FOLLOWED The UPS battery charges whenever the UPS is connected to utility power amp is switched ON It typically requires twelve hours to charge fully Operating runtime is reduced until the battery is fully charged TEST THE UPS To test UPS on battery back up disconnect the power cord and observe backup Indicator lights Your PC or other connected equipment should continue to function normally until the UPS battery is drained of power UPS Indicators and Controls
2. AC NORMAL green light 9 AC NORMAL green light _C_ CHARGING yellow light O BACKUP yellow light O BACKUP red light O FAULT red light O POWER POWER Figure 8 LED display mode 1 Figure 9 LED display mode 2 E Operating by the LED display mode 1 Reference the figure 8 1 ON OFF BUTTON Turn ON this button to supply power to the UPS outlets To switch off power to the UPS outlets turn OFF the switch This switch is situated on the front panel of the UPS 2 AC NORMAL INDICATOR Green light continuous The UPS is supplying conditioned utility power to 1ts outlets 3 CHARGING INDICATOR yellow light continuous The UPS is supplying conditioned utility power to its outlets and the battery is charging 4 BACKUP INDICATOR red light slow blinking The indicator starts slow blinking when utility power is outside acceptable limits The battery is powering the UPS outlets 5 SLOW BEEPPING A one second duration tone is sounded two seconds after utility power loss has occurred The UPS will continue to run with an audible alarm until a low battery condition is reached 6 LOW BATTERY INDICATOR Red light fast blinking The indicator starts fast blinking whenever the battery is near the end of its runtime 7 FAST BEEPING The UPS is near the end of its battery runtime promptly save your data and exit all applications and shutdown the operating sys
3. e Under direct sunlight or close to heating facilities e Place of strong vibrations 8 In the event of fire occurring in the vicinity please use dry powder fire extinguishers The use of liquid fire extinguishing agents may cause electric shock INSTALLATION AND OPERATION Before installation please read and understand the following instructions Inspect the following items inside box User Manual UPS UNPACKING AND INSPECTION Examine the packing carton for damage Notify your dealer immediately if damage is observed Store the packing in a safe place for possible future shipment of the UPS PLACE THE UPS Position the UPS on a sturdy dry surface in a well ventilated area away from direct sources of heat Leave at least 100mm clearance all around the UPS to provide adequate ventilation Reference figure 1 Figure 1 Figure 2 The UPS is intended for indoor use only Although your UPS is very rugged its internal components are not sealed from the environment Please kindly note the following Reference figure 2 Avoid direct sunlight Avoid excessive heat Avoid excessive humidity or liquids Avoid excessive dust CONNECT THE UPS TO A 110VAC POWER OUTLET Connect the Power Cord to a verified grounded 3 wire receptacle Do not power the UPS using a surge suppressor or power strip Switch the main supply SWITCH ON Reference figure 3
4. DI UPS SERIES DT UPS 500 DT UPS 1200 For assistance contact our DataTronix Technicians at 610 429 1511 1 1 Description of Commonly Used Symbols Some or all of the following symbols may be used in this manual and may appear in your application process Therefore all users should read the form carefully and thoroughly Symbol amp Description Symbol Description Caution danger Danger electric shock Alternating current AC Direct current DC Protective ground Recycle ls Do not dispose with ordinary trash 1 2 Safety Instructions Read this manual carefully and thoroughly before operation the UPS and save this manual properly for future reference N Do not tear up or shatter the alarm table on the UPS and pay attention to it Please do not overload the UPS The UPS contains large capacity batteries The case of the UPS must not be opened by untrained personnel Pp Otherwise it may cause electric shock 5 Do not short the positive and negative electrodes of battery Otherwise it may cause electric shock or fire 6 Do not plunge or insert any objects into the air vents and other inlets 7 Do not store or use the device in the following environment O Where there is inflammable gas corrosive agents or heavy dust e Where the temperature is very high or low above 40 C 104 F or below 0 C 32 F or the humidity is very high more than 90
5. as from original purchase Any claim under the warranty must include dated proof of purchase or invoice In any event the Company s liability for defective hardware is limited to repairing or replacing the hardware This warranty is contingent upon proper use of the hardware by Original Purchaser and does not cover if damage is due to Acts of God including fire flood earthquake storm hurricane or other natural disaster accident unusual physical electrical or electromechanical stress modifications neglect misuse operation with media not approved by the Company tampering with or altering of the hardware riot war invasion act of foreign enemies hostilities regardless of whether war is declared civil war rebellion revolution insurrection military or usurped power or confiscation terrorist activities nationalization government sanction blockage embargo labor dispute strike lockout or interruption or failure of electricity air conditioning or humidity control internet network or telephone service The warranties given herein together with any implied warranties covering the hardware including any warranties of merchantability or fitness for a particular purpose are limited in duration to one year from the date of shipment to the Original Purchaser Jurisdictions vary with regard to the enforceability of warranty limitations and you should check the laws of your local jurisdiction to find out whether the above limit
6. of problem 3 Full description of problem TROUBLE SHOOTING CHART SYMPTOMS POSSIBLE CAUSE ACTIONS TO TAKE UPS can not turn ON 8 no UPS front panel switch not turned ON Turn ON UPS front panel switch Check input power at end of power cord indications no alarms No incoming utility line i 9 y and wall socket Otherwise call for service 1 Reduce the load and replace fuse vvith Rear panel input fuse open UPS suddenly turns to battery same rating mode in spite of utility line Input utility line too high or too low Check input line voltage at Frequency out of range Check input frequency This is not a fault The UPS is indicating Single beep Normal UPS operation that it is protecting the load during a momentary power loss Recharge the battery for at least 8 hours Back up time less than Specified Battery is not fully charged and re lest the backup time if problem persists call for service UPS is normal but the computer Computer input power cord is loose or not Reconnect computer input power cord wond turn on connected P Pup SERVICE DO NOT ATTEMPT TO SERVICE THE SYSTEM YOURSELF NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL ONLY Do not connect to Life Support systems We do not recommend the use of our UPS products for life support equipment or direct care where failure of a UPS product could cause failure of or diminished effectiveness of th
7. ation applies to you The Company shall not be liable to you for loss of data loss of profits lost savings special incidental consequential indirect or other similar damages arising from breach of warranty breach of contract negligence or other legal action even if the Company or its agent has been advised of the possibility of such damages or for any claim brought against your by another party Jurisdictions vary with regard to the enforceability of provisions excluding or limiting liability for incidental or consequential damages You should check the laws of your local jurisdiction to find out whether the above exclusion applies to you This warranty allocates risks of product failure between Original Purchaser and the Company The Company s hardware pricing reflects this allocation of risk and the limitations of liability contained in this warranty The warranty set forth above is in lieu of all other express warranties whether oral or written The agents employees distributors and dealers of the Company are not authorized to make modification to this warranty or additional warranties binding on the Company Accordingly additional statements such as dealer advertising or presentations whether oral or written do not constitute warranties by the Company and should not be relied upon This warranty gives you specific legal rights You may also have other rights which vary from one jurisdiction to another
8. e life support equipment of patient care DATATRONIX 1 Year Limited Warranty DATATRONIX the Company warrants to the Original Purchaser that the item purchased is free from defects in workmanship or material under normal use This warranty starts on the date of shipment of the hardware to the Original Purchaser During the warranty period the Company agrees to repair or replace at its sole option without charge to Original Purchaser any defective component To obtain service the Original Purchaser must return the item to the Company properly packaged for shipping All defective products must be returned to the Company within thirty 30 days of failure Products must be returned with a description of the failure and Return Merchandise Authorization RMA number supplied by the Company To receive a RMA number and a return shipping address on where to deliver the hardware call 610 429 1821 The shipping and insurance charges incurred in shipping to the Company will be paid by Original Purchaser and all risk for the hardware shall remain with the Original Purchaser until such time as Company takes receipt of the hardware Upon receipt the Company will promptly repair or replace the defective unit and then return said unit to Original Purchaser shipping prepaid The Company may use reconditioned or like new parts or units at its sole option when repairing any hardware Repaired products shall carry the same amount of outstanding warranty
9. ed equipment Turn off the UPS ON OFF Switch which is situated on the front panel of the UPS COLD START When the UPS is Off and there is no utility power it is possible to power essential equipment connected to UPS for a short period of time Make sure that only the most necessary equipment is connected to the UPS at this time 1 Turn ON the UPS ON OFF switch 2 Complete what you need to do with the powered equipment before the UPS battery is fully discharged 3 Shut off the connected equipment 4 Turn OFF the UPS ON OFF switch Technical specification Model 400 500 600 700 800 1000 1200 Power factor 0 6 Load type Personal computers and other PC peripheral devices Mains voltage range 140 290 5Vac or 70 145 5Vac Mains frequency range 40 70 1Hz Output voltage range Line mode 110Vac 120Vac 220Vac 230Vac 10 Sine wave Output frequency range Line mode Synch with mains input Output voltage range battery mode 110Vac 120Vac 220 Vac 230Vac 5 Square wave Output frequency range battery mode 50 60 1Hz frequency self adapt system Battery No load protection Auto protection The UPS will automatically shut down after 2min no load detected Transfer time lOms Battery backup time gt 6Min half load Battery protection Auto protection The UPS will automatically shut down when battery voltage is low or
10. high Battery charging time 8 hours to 90 Short circuit protection Auto protection Output shuts off and the buzzer beeps continuously Overload protection 110 lt load percentageO 120 buzzer beeps load percentage gt 120 output shuts off buzzer beeps continuously Operating temperature 0 C 40 C Storage temperature 15 C 45 C Relative humidity 0 90 No condensation water Noise B5dB im from front panel 230190 291 90 Size LxWxH mm 330 90 145 340x122x190 145 145 Net weight Kgs 4 4 5 14 5 5 52 84 94 Note The specification listed above is subject to change without notice SAFETY THE UPS CONTAINS VOLTAGE WHICH IS POTENTIALLY HAZARDOUS QUALIFIED SERVICE PERSONNEL SHOULD PERFORM ALL REPAIRS THE UPS HAS ITS OWN INTERNAL ENERGY SOURCE BATTERY THE OUTPUT RECEPTACLES MAY BE LIVE EVEN WHEN THE UPS IS NOT CONNECTED TO AN AC SUPPLY TROUBLE SHOOTING The trouble shooting chart covers most of the difficulties that you may encounter under normal working conditions If the UPS fails to operate properly please review the following steps before calling the service center 1 Is the UPS plugged into a correct working outlet 2 IS the line voltage within the rating specified 3 Is the fuse circuit protector on back panel open Please submit the following information when you call for service 1 Model No amp Serial No 2 Date
11. tem H Operating by the LED display mode 2 Reference the figure 9 1 ON OFF BUTTON Turn ON this button to supply power to the UPS outlets To switch off power to the UPS outlets turn OFF the switch This switch is situated on the front panel of the UPS AC NORMAL INDICATOR Green light continuous The UPS is supplying conditioned utility power to its outlets BACKUP INDICATOR yellow light slow blinking The indicator starts slow blinking when utility power is outside acceptable limits The battery is powering the UPS outlets The expected runtime for a typical personal computer PC is about 10 to 20 minutes SLOW BEEPPING A one second duration tone is sounded two seconds after utility power loss has occurred The UPS will continue to run with an audible alarm until a low battery condition is reached FAULT INDICATOR Red light fast blinking The indicator starts fast blinking whenever the battery is near the end of its runtime FAST BEEPING The UPS is near the end of its battery runtime promptly save your data and exit all applications and shutdown the operating system Manual Shutdown When the UPS is operating on battery the procedure below can be performed to conserve battery charge and not allow the connected equipment to have power removed without being properly shut down 1 2 3 4 5 Save important working files Exit all applications Exit the operating system Shut down the connect