Home

USER MANUAL - Kramer Electronics

image

Contents

1. K Figure 3 Local Area Connection Properties Window 4 Highlight either Internet Protocol Version 6 TCP IPv6 or Internet Protocol Version 4 TCP IPv4 depending on the requirements of your IT system 5 Click Properties The Internet Protocol Properties window relevant to your IT system appears as shown in Figure 4 or Figure 5 FC 10ETH Configuring the FC 10ETH Ethernet Controller General Alternate Configuration You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Use the following IP address IP address Subnet mask Default gate Obtain DNS server address automatically Use the following DNS server addresses Preferred DNS server Alternate DNS server El Validate settings upon exit Figure 4 Internet Protocol Version 4 Properties Window cen You can get IPv6 settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IPv6 settings Obtain an IPv6 address automatically Use the following IPv6 address IPv6 address Subnet prefix length Default gat D Obtain DNS server address automatically Use the following DNS server addresses Preferred DNS server Alternate DNS server C Valid
2. LEGAL THEORY Some countries districts or states do not allow the exclusion or limitation of relief special incidental consequential or indirect damages or the limitation of liability to specified amounts so the above limitations or exclusions may not apply to you Exclusive Remedy TO THE MAXIMUM EXTENT PERMITTED BY LAW THIS LIMITED WARRANTY AND THE REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES REMEDIES AND CONDITIONS WHETHER ORAL OR WRITTEN EXPRESS OR IMPLIED TO THE MAXIMUM EXTENT PERMITTED BY LAW KRAMER ELECTRONICS SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IF KRAMER ELECTRONICS CANNOT LAWFULLY DISCLAIM OR EXCLUDE IMPLIED WARRANTIES UNDER APPLICABLE LAW THEN ALL IMPLIED WARRANTIES COVERING THIS PRODUCT INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY TO THIS PRODUCT AS PROVIDED UNDER APPICABLE LAW IF ANY PRODUCT TO WHICH THIS LIMITED WARRANTY APPLIES IS A CONSUMER PRODUCT UNDER THE MAGNUSON MOSS WARRANTY ACT 15 U S C A 2301 ET SEQ OR OTHER APPICABLE LAW THE FOREGOING DISCLAIMER OF IMPLIED WARRANTIES SHALL NOT APPLY TO YOU AND ALL IMPLIED WARRANTIES ON THIS PRODUCT INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR THE PARTICULAR PURPOSE SHALL APPLY AS PROVIDED UNDER APPLICABLE LAW Other Conditions This limited warranty gives you specifi
3. on your FC 10ETH The Kramer VSPM software lets you emulate virtual ports which normally would be present in the machine hardware After setup the virtual port lets you control Kramer machines via your PC ica FC 10ETH Controlling Machines via the Ethernet using the FC 10ETH 5 1 2 Setting an Ethernet Connection If the control application can directly connect to the Ethernet driver select the host IP and port number according to your FC 10ETH configuration as illustrated in Figure 10 Remote Connection Remote Settings RemoteHost 192 168 0 40 RemotePort 5001 Figure 10 The Port Window Selecting a Remote Connection 5 2 Controlling a Kramer Machine via a Serial Controller To control a Kramer machine via serial controllers in the Active routing mode as illustrated in the example in Figure 11 do the following For passive and active routing modes see Section 4 4 1 Connect the FC 10ETH A 12V DC power adapter to the power socket and connect the adapter to the mains electricity 2 Configure the FC 10ETH A to the Passive routing mode see Section 4 4 1 3 Disconnect unit A Unit A is configured to the Passive mode 4 Connect the FC 10ETH B 12V DC power adapter to the power socket and connect the adapter to the mains electricity 5 Configure the FC 10ETH B to the Active routing mode see Section 4 4 2 and then Disconnect unit B Make sure that the Destin IP set in unit B is ide
4. Configuring the FC 10ETH Ethernet Controller 4 2 FC 10ETH Configuring the FC 10ETH Ethernet Controller Installing and Configuring the FC 10ETH To configure the FC 10ETH via the ETHERNET do the following 1 Connect the FC 10ETH as described in Section 4 1 see Figure 7 2 Click the appropriate shortcut in the Start menu s Programs folder The FC 10ETH Configuration Manager window see Figure 8 opens 3 Click the Search button to automatically search for devices or the Search Board command on the Action menu The MAC Address for the found FC 10ETH appears in the Device List 4 Change the settings according to your network requirements and then click the Config button or the Config command on the Action menu to apply the settings Note that clicking the Config button will alter the IP settings of the FC 10ETH To a Kramer Machine To a Kramer Machine LL DANADDAADADANAAAANAJI gt 4 i OS A Figure 7 Connecting the FC 10ETH for Configuration 4 3 Defining the Kramer FC 10ETH Manager I KRAMER FC 10ETH MANAGER t 2 FC 10ETH seting bai Firmware Version 221 lt a a E Mac Address 0010 560081 58 Network Settings IP Address 2 162 oo os lt _ __ 7 Subnet 255 255 000 000 Gateway 192 168 001 001 Channel 1 Channel 2 Local iP pert 5000 Local IP port 5001 UART Speed 9800 iv UART Speed 9800 oO UART Parity None i UART
5. FC 10ETH 5 1 Controlling a Machine via a Computer 5 2 Controlling a Kramer Machine via a Serial Controller 6 Flash Memory Upgrade 6 1 Upgrading Version 1 Devices 6 2 Upgrading Version 2 Devices 7 Technical Specifications Figures Figure 1 FC 10ETH Ethernet Controller Figure 2 Underside of the FC 10ETH Ethernet Controller Figure 3 Local Area Connection Properties Window Figure 4 Internet Protocol Version 4 Properties Window Figure 5 Internet Protocol Version 6 Properties Window Figure 6 Internet Protocol Properties Window Figure 7 Connecting the FC 10ETH for Configuration Figure 8 FC 10ETH Manager Window Figure 9 Connecting the FC 10ETH in the Passive Routing Mode Figure 10 The Port Window Selecting a Remote Connection Figure 11 Connecting the FC 10ETH in the Active Routing Mode Figure 12 The KFR Programmer Window N oP WONMNYD Introduction Welcome to Kramer Electronics Since 1981 Kramer Electronics has been providing a world of unique creative and affordable solutions to the vast range of problems that confront video audio presentation and broadcasting professionals on a daily basis In recent years we have redesigned and upgraded most of our line making the best even better Our 1 000 plus different models now appear in 11 groups that are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GRO
6. FC 10ETH data buffer is limited to 128 bytes Control of two RS 232 devices or one RS 232 device and one RS 485 device via Ethernet from a PC set to the Passive routing mode or other protocol compatible remote controller Device control from up to five Ethernet points PCs or remote controllers Windows based Configuration Management software for configuring the FC 10ETH unit including routing mode settings network settings serial settings and destination device settings Internet system remote control requiring only a dedicated IP address and a modem in the remote location whether it is a standalone PC or a LAN system A 128 byte data buffer making it compatible with most non Kramer protocols The FC 10ETH includes the Virtual Serial Port Manager Kramer VSPM for compatibility with applications based on COM port communication The virtual serial port Makes the FC 10ETH compatible with all Windows based applications that work through an actual COM port This includes all versions of K Router and other Kramer control applications It lets you operate all RS 232 and RS 485 controllable devices via Ethernet LAN using their existing PC software Operates like an actual hardware port that is a logical COM that behaves like a standard hardware COM but in reality transparently reroutes the data using the TCP IP network to the FC 10ETH interface via a Virtual null modem connection which you can emulate over the Ethernet or Intern
7. KRAMER ELECTRONICS LTD USER MANUAL MODEL FC 10O0ETH Ethernet Controller P N 2900 000086 Rev 3 Elb E FC 10ETH Quick Start Guide This guide helps you install and use your product for the first time For more detailed information go to http www kramerelectronics com support product_downloads asp E to download the latest manual or scan the QR code on the left Step 1 Check what s in the box FC 10ETH Ethernet Controller s Rubber feet A A 1 Power supply 12V DC 1 Quick Start sheet Step 2 Install the FC 10ETH Attach the rubber feet and place on a table or mount the FC 10ETH in a rack using an optional RK 3T rack mount Step 3 Connect the inputs and outputs Kramer Computer Kramer Machine Controller Machine Step 4 Connect the power Connect the 12V DC power adapter to the FC 10ETH and plug the adapter ff into the mains electricity Step 5 Operate the FC 10ETH Configure the FC 10ETH using Kramer s Configuration Manager software Contents 1 Introduction 2 Getting Started 2 1 Achieving the Best Performance 2 2 Safety Instructions 2 3 Recycling Kramer Products 3 Overview 3 1 Defining the FC 10ETH Ethernet Controller 4 Configuring the FC 10ETH Ethernet Controller 4 1 Operating via Ethernet 4 2 Installing and Configuring the FC 10ETH 4 3 Defining the Kramer FC 10ETH Manager 4 4 Routing Data 5 Controlling Machines via the Ethernet using the
8. Kramer machines FC 10ETH A Connect the 12V DC power adapter to the power socket and connect the adapter to the mains electricity FC 10ETH B Connect the 12V DC power adapter to the power socket and connect the adapter to the mains electricity The serial controllers A connection is established after the user sends the first command from the serial controller to the serial controlled device 7 eo qe x i P ees 148 FC 10ETH Controlling Machines via the Ethernet using the FC 10ETH Serial Controller KRAMER TOOLS Ethernet Controller Serial Controller STATUS STATUS COM 1 COM 2 m Kramer Machine 2 RS 232 ETHERNET RS 232 ABG COM 1 COM2 RS 485 KRAMER TOOLS K Ethernet Controller FC 10ETH STATUS STATUS ON COM 1 COM2 Figure 11 Connecting the FC 10ETH in the Active Routing Mode FC 10ETH Controlling Machines via the Ethernet using the FC 10ETH 19 6 6 1 6 1 2 Flash Memory Upgrade The FC 10ETH firmware is located in FLASH memory which lets you upgrade to the latest Kramer firmware version in minutes Upgrading Version 1 Devices The process involves e Downloading the upgrade package from the Internet see Section 6 1 1 e Connecting the PC to the RS 232 port COM 1 see Section 6 1 2 e Upgrading the firmware see Section 6 1 3 Downloading from the Internet You can download the up to date file from the Internet file names are liable to change from time to time To
9. Parity None B 12 aes 43 Destination 192 168 001 O47 Destination iP 182 168 001 042 Port 5000 Port 5000 i Figure 8 FC 10ETH Manager Window l Feature l Function DEVICE Search for all connected devices Upload configuration to device same as button 4 1 SETTINGS Sets the broadcast address and the broadcast network interface Displays software development information including the software version 2 Search Button Seeks the FC 10ETH devices that connect to the PC via the ETHERNET port and displays them and their corresponding settings Device List Displays the MAC Addresses for the FC 10ETH devices Menu Bar gt W O Cc j connected via the selected port LAN or COM and the version V1 and V2 of the device FC 10ETH Setting VERSION SUBNET A 32 binary digit number obtained from your Network Administrator which combined with the IP Address identifies which network your FC 10ETH device is on UPLOAD TO DEVICE Press to upload the displayed configuration to the device MAC ADDRESS Displays the MAC Addresses for the FC 10ETH devices connected via the selected port LAN or COM GATEWAY A network position serving as an entry to another network or to the Internet only relevant in the Active Routing mode FIRMWARE Displays the firmware version IP ADDRESS A 32 binary digit number obtained from your Network Administrator that identifies the FC 10ETH device that is currently being configured
10. UP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9 Room Connectivity GROUP 10 Accessories and Rack Adapters and GROUP 11 Sierra Video Products Congratulations on purchasing your Kramer FC 10ETH Ethernet Controller which is ideal for use with Ethernet RS 232 interfaces and or Ethernet RS 485 interfaces 2 1 2 2 Getting Started We recommend that you e Unpack the equipment carefully and save the original box and packaging materials for possible future shipment Review the contents of this user manual Go to http www kramerelectronics com support product_downloads as to check for up to date user manuals application programs and to check if firmware upgrades are available where appropriate Achieving the Best Performance To achieve the best performance e Use only good quality connection cables we recommend Kramer high performance high resolution cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables e Do not secure the cables in tight bundles or roll the slack into tight coils e Avoid interference from neighboring electrical appliances that may adversely influence signal quality e Position your Kramer FC 10ETH away from moisture excessive sunlight and dust This equipment is to be used only inside a buil
11. ate settings upon exit Figure 5 Internet Protocol Version 6 Properties Window FC 10ETH Configuring the FC 10ETH Ethernet Controller Es 6 Select Use the following IP Address for static IP addressing and fill in the details as shown in Figure 6 For TCP IPv4 you can use any IP address in the range 192 168 1 1 to 192 168 1 255 excluding 192 168 1 39 that is provided by your IT department You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address m m 1 2 Subnet mask 255 255 255 0 Default gateway IE Obtain DNS server address automatically Use the following DNS server addresses Preferred DNS server Alternate DNS server E Validate settings upon exit Figure 6 Internet Protocol Properties Window 7 Click OK 8 Click Close Connecting the Ethernet Port via a Network Hub or Switch You can connect the Ethernet port of the FC 10ETH to the Ethernet port on a network hub or using a straight through cable with RJ 45 connectors Control Configuration via the Ethernet Port To control several units via Ethernet connect the Master unit Device 1 via the Ethernet port to the Ethernet port of your PC Use your PC provide initial configuration of the settings see Section 4 1 FC 10ETH
12. ate the repair of any defective parts within a reasonable period of time free of any charge for the necessary parts and labor to complete the repair and restore this product to its proper operating condition Kramer Electronics will also pay the shipping costs necessary to return this product once the repair is complete 2 Replace this product with a direct replacement or with a similar product deemed by Kramer Electronics to perform substantially the same function as the original product 3 Issue a refund of the original purchase price less depreciation to be determined based on the age of the product at the time remedy is sought under this limited warranty What Kramer Electronics will not do Under This Limited Warranty If this product is returned to Kramer Electronics or the authorized dealer from which it was purchased or any other party authorized to repair Kramer Electronics products this product must be insured during shipment with the insurance and shipping charges prepaid by you If this product is returned uninsured you assume all risks of loss or damage during shipment Kramer Electronics will not be responsible for any costs related to the removal or re installation of this product from or into any installation Kramer Electronics will not be responsible for any costs related to any setting up this product any adjustment of user controls or any programming required for a specific installation of this product How to Obtain a Remedy unde
13. c legal rights and you may have other rights which vary from country to country or state to state This limited warranty is void if i the label bearing the serial number of this product has been removed or defaced ii the product is not distributed by Kramer Electronics or iii this product is not purchased from an authorized Kramer Electronics reseller If you are unsure whether a reseller is an authorized Kramer Electronics reseller please visit our Web site at www kramerelectronics com or contact a Kramer Electronics office from the list at the end of this document Your rights under this limited warranty are not diminished if you do not complete and return the product registration form or complete and submit the online product registration form Kramer Electronics thanks you for purchasing a Kramer Electronics product We hope it will give you years of satisfaction For the latest information on our products and a list of Kramer distributors visit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com KRAMER E mail info kramerel com SAFETY WARNING Disconnect the unit from the power supply before opening and servicing P N 2900 000086 Rev 3
14. ces refer to the K Upload User Guide available at http Awww kramerelectronics com support product_downloads asp 7 Technical Specifications ETHERNET INTERFACE 10 100BaseT Ethernet SERIAL INTERFACES 2 RS 232 connectors signals RX TX RTS CTS Ground on 9 pin D sub ports 1 RS 485 on a detachable terminal block connector NETWORK PROTOCOLS ICMP ARP ping TCP UDP POWER CONSUMPTION 12V DC 140mA DIMENSIONS 12cm x 7 5cm x 2 5cm 4 7 x 2 95 x 0 98 W D H WEIGHT 0 3kg 0 25lbs approx ACCESSORIES Power supply mounting bracket OPTIONS RK 3T 19 rack adapter Specifications are subject to change without notice Go to our Web site at http www kramerelectronics com to access the list of resolutions FC 10ETH Technical Specifications LIMITED WARRANTY The warranty obligations of Kramer Electronics for this product are limited to the terms set forth below Whatis Covered This limited warranty covers defects in materials and workmanship in this product What is Not Covered This limited warranty does not cover any damage deterioration or malfunction resulting from any alteration modification improper or unreasonable use or maintenance misuse abuse accident neglect exposure to excess moisture fire improper packing and shipping such claims must be presented to the carrier lightning power surges or other acts of nature This limited war
15. ding It may only be connected to other equipment that is installed inside a building Safety Instructions Caution There are no operator serviceable parts inside the unit Warning Use only the Kramer Electronics input power wall adapter that is provided with the unit Warning Disconnect the power and unplug the unit from the wall before installing 2 3 Recycling Kramer Products The Waste Electrical and Electronic Equipment WEEE Directive 2002 96 EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled To comply with the WEEE Directive Kramer Electronics has made arrangements with the European Advanced Recycling Network EARN and will cover any costs of treatment recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN facility For details of Kramer s recycling arrangements in your particular country go to our recycling pages at Attp www kramerelectronics com support recycling Overview The high performance FC 10ETH Ethernet Controller is an easy to use bidirectional hardware and software interface system for controlling Kramer and also non Kramer RS 232 and or RS 485 controllable machines via Ethernet LAN as well as via the Internet In particular the FC 10ETH features Network connectivity that lets you connect a Kramer or other device via its RS 232 or RS 485 port to the Ethernet LAN network The
16. download 1 Go to our Web site at http www kramerelectronics com and download the file f 10eth_11 zip from the technical support section 2 Extract the file f 70eth_11 zip package which includes the KFR Programmer application setup and the s79 firmware file to a folder for example C Program Files KFR Upgrade 3 Install the KFR Programmer Application Connecting the PC to the RS 232 Port Before installing the latest Kramer firmware version on the FC 10ETH do the following 1 Connect the RS 232 9 pin D sub port COM 1 on the FC 10ETH to a null modem adapter and connect the null modem adapter with a 9 wire flat cable to the RS 232 9 pin D sub COM port on your PC 2 Set the PROG dipswitch to ON 3 Connect the power on your machine 6 1 3 Upgrading the Firmware Follow these steps to upgrade the firmware 1 Double click the KFR Programmer desktop icon The KFR Programmer window appears see Figure 12 T KFR Progra 215 x COM PORT C coM1 m C CoM2 Send C COM3 ain C coM4 Figure 12 The KFR Programmer Window 2 Select the required COM Port to which the FC 10ETH is connected on your PC 3 Press the File button to select the s79 firmware file included in the package 4 Press the Send button to download the file The Send button lights red 5 Wait until downloading is completed and the red Send button turns off 6 2 Upgrading Version 2 Devices To upgrade the firmware of Version 2 devi
17. et Can be created in any quantity on your PC and does not occupy an actual serial port 3 1 Defining the FC 10ETH Ethernet Controller 12V DC RS 232 ETHERNET RS 232 COM 1 COM 2 Ethernet Controller FC 10OETH STATUS STATUS COM 1 COM 2 Eq 914N09 o Figure 2 Underside of the FC 10ETH Ethernet Controller FC 10ETH Overview Feature Function 12V DC 12V DC connector for powering the unit 2 RS 232 COM 1 Port Connects to the RS 232 9 pin D sub port on the Kramer or other device 1 or PC ETHERNET Port Connects to your LAN 4 RS 232 COM 2 Port Connects to the RS 232 9 pin D sub port on a Kramer or other device 2 or PC A Kramer device can be connected to either the RS 232 COM 2 port or to the RS 485 terminal block port but not to both 5 RS 485 Terminal Connects to the RS 485 port on a Kramer or other device Block Port A Kramer device can be connected to either the RS 232 COM 2 port or to the RS 485 terminal block port but not to both PIN A connects to the A PIN PIN B connects to the B PIN and PIN G connects to the G Ground PIN if necessary The connection to G is usually not necessary for RS 485 STATUS COM 1 LEDs Lit when a signal is transmitted or received from port 1 mostly used for troubleshooting 7 STATUS COM 2 LEDs Lit when a signal is transmitted or received from port 2 mostly used for troubleshooting ON LED Lit when receiv
18. in the Ethernet or Internet FC 10ETH Configuring the FC 10ETH Ethernet Controller 4 4 4 4 1 FC 10ETH l Feature l Function LOCAL IP PORT An address for the local ports COM 1 and COM 2 on the FC 10ETH device that is currently being configured which provides a direct route from another Ethernet point application UART SPEED Choose the appropriate baud speed 1200 2400 4800 9600 19200 38400 57600 or 115200 UART PARITY Choose the required parity None Odd Even Mark or Space ACTIVE Checkbox When cleared activates the Passive mode see Section 4 4 1 When selected activates the Active mode see Section 4 4 2 Note Only appears for V1 devices not present for V2 devices DESTINATION IP_ A 32 binary digit number that identifies the destination FC 10ETH device in the Ethernet or Internet PORT A pre assigned address of the destination FC 10ETH device that provides a direct route to its Transport layer The Destination Settings area is active only when the Active Mode check box is selected Routing Data D amp E o 2 o fa fa oO O s oO a There are two versions of the FC 10ETH version 1 V1 and version 2 V2 The version is shown on the Device List entry see item 3 on Figure 8 e V1 devices use passive see Section 4 4 1 and active Section 4 4 2 routing modes The Active checkbox see item 13 on Figure 8 is displayed only for V1 devices e 2 devices only use the passive ro
19. ing power RESET Button Press to reset the machine Turns the machine off and on again while retaining its definitions identical to disconnecting the power adapter and then connecting it again 10 RS 485 TERM Button Press for BUS termination Set to OFF if the RS 485 terminal block port is not connected Set to ON if the RS 485 terminal block port is connected FACTORY RESET Press to reset to factory default definitions Button First disconnect the power adapter and then connect it again while pressing the FACTORY RESET button The unit will power up and load its memory with the factory default definitions PROG Switch Switch ON to upgrade firmware CONFIG Switch Not used set to OFF FC 10ETH Overview 4 4 1 Configuring the FC 10ETH Ethernet Controller This section describes e How to connect the FC 10ETH for configuration via its ETHERNET port see Section 4 1 e How to install and run the Configuration Manager software see Section 4 2 e The Configuration Manager Window features see Section 4 3 Operating via Ethernet You can connect to the product via Ethernet using either of the following methods e Directly to the PC using a crossover cable see Section 4 1 1 e Via a network hub switch or router using a straight through cable see Section 4 1 2 Note If you want to connect via a router and your IT system is based on IPv6 speak to your IT department for specific installation instructions Con
20. necting the Ethernet Port Directly to a PC You can connect the Ethernet port of the FC 10ETH directly to the Ethernet port on your PC using a crossover cable with RJ 45 connectors This type of connection is recommended for identifying the FC 10ETH with the factory configured default IP address After connecting the FC 10ETH to the Ethernet port configure your PC as follows 1 Click Start gt Control Panel gt Network and Sharing Center 2 Click Change Adapter Settings 3 Highlight the network adapter you want to use to connect to the device and click Change settings of this connection ynfiguring the FC 10ETH Ethernet Controller The Local Area Connection Properties window for the selected network adapter appears as shown in Figure 3 Sharing Connect using Intel R 82579V Gigabit Network Connection This connection uses the following items 0M Client for Microsoft Networks M Z Microsoft Network Monitor 3 Driver dZ QoS Packet Scheduler iS File and Printer Sharing for Microsoft Networks Bd Intemet Protocol V 4 Intemet Protocol Version 4 TCP IPv4 Link Layer Topology Discovery Mapper 1 0 Driver 4 Link Layer Topology Discovery Responder Install Uninstall Properties Descripti TCP IP version 6 The latest version of the intemet protocol that provides communication across diverse interconnected networks K S K lt K
21. ntical to the IP address on unit A Destination Settings Area for CHANNEL 1 and CHANNEL 2 of unit B are set to be identical to the Port numbers in the Local Ports on CHANNEL 1 and CHANNEL 2 or according to the connections we want to establish with unit A FC 10ETH Controlling Machines via the Ethernet using the FC 10ETH 17 Unit B is configured to the Active mode 6 Connect units A and B to your network or Ethernet router as illustrated in Figure 11 7 Connect up to two machines that is the RS 232 COM 1 port of the FC 10ETH A to the RS 232 port of your machine 1 for example a Kramer machine via a null modem adapter COM 2 port of the FC 10ETH A to the RS 232 port of your machine 2 for example a Kramer machine via a null modem adapter alternatively you can connect the RS 485 port of unit A to the RS 485 port of your Kramer machine To connect the RS 485 port connect PIN A to the A PIN and PIN B to the B PIN 8 Connect up to two serial controllers to unit B Connect the RS 485 terminal block of the serial controller 1 to the RS 485 terminal block port on the FC 10ETH B Alternatively you can connect an RS 232 output terminal block of the serial controller to the RS 232 COM 2 port of the FC 10ETH Connect the RS 232 port of the serial controller 2 to the RS 232 COM 1 port on the FC 10ETH B 9 Connect the power on each of the devices as follows The
22. r this Limited Warranty To obtain a remedy under this limited warranty you must contact either the authorized Kramer Electronics reseller from whom you purchased this product or the Kramer Electronics office nearest you For a list of authorized Kramer Electronics resellers and or Kramer Electronics authorized service providers please visit our web site at www kramerelectronics com or contact the Kramer Electronics office nearest you In order to pursue any remedy under this limited warranty you must possess an original dated receipt as proof of purchase from an authorized Kramer Electronics reseller If this product is returned under this limited warranty a return authorization number obtained from Kramer Electronics will be required You may also be directed to an authorized reseller or a person authorized by Kramer Electronics to repair the product If itis decided that this product should be returned directly to Kramer Electronics this product should be properly packed preferably in the original carton for shipping Cartons not bearing a return authorization number will be refused Limitation on Liability THE MAXIMUM LIABILITY OF KRAMER ELECTRONICS UNDER THIS LIMITED WARRANTY SHALL NOT EXCEED THE ACTUAL PURCHASE PRICE PAID FOR THE PRODUCT TO THE MAXIMUM EXTENT PERMITTED BY LAW KRAMER ELECTRONICS IS NOT RESPONSIBLE FOR DIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION OR UNDER ANY OTHER
23. ranty does not cover any damage deterioration or malfunction resulting from the installation or removal of this product from any installation any unauthorized tampering with this product any repairs attempted by anyone unauthorized by Kramer Electronics to make such repairs or any other cause which does not relate directly to a defect in materials and or workmanship of this product This limited warranty does not cover cartons equipment enclosures cables or accessories used in conjunction with this product Without limiting any other exclusion herein Kramer Electronics does not warrant that the product covered hereby including without limitation the technology and or integrated circuit s included in the product will not become obsolete or that such items are or will remain compatible with any other product or technology with which the product may be used How Long Does this Coverage Last Seven years as of this printing please check our Web site for the most current and accurate warranty information Whois Covered Only the original purchaser of this product is covered under this limited warranty This limited warranty is not transferable to subsequent purchasers or owners of this product What Kramer Electronics will do Kramer Electronics will at its sole option provide one of the following three remedies to whatever extent it shall deem necessary to satisfy a proper claim under this limited warranty 1 Elect to repair or facilit
24. rt of the FC 10ETH to the RS 232 port of your Kramer non Kramer machine 1 via a null modem COM 2 port of the FC 10ETH to the RS 232 port of your Kramer non Kramer machine 2 via a null modem alternatively you can connect the RS 485 terminal block port of the FC 10ETH to the RS 485 port of your Kramer non Kramer machine To connect the RS 485 block port Connect PIN A to the A PIN and PIN B to the B PIN 4 Connect the ETHERNET port of your FC 10ETH to a LAN using a straight through cable with RJ 45 connectors You can control from up to 5 computers three via COM1 and two via COM 2 each with its control software 5 Run the Kramer Windows based control software to control the Kramer machine from each computer When working with a non Kramer device use that device s PC software 6 Select either A virtual COM port if the control application cannot directly connect to the Ethernet driver see Section 5 1 1 or An Ethernet port connection if the control application can directly connect to the Ethernet driver see Section 5 1 2 Power 1zv0C RS 232 COM 1 KRAMER TOOLS ETHERNET RS 232 COM 2 Ethernet Controller STATUS COM 2 Figure 9 Connecting the FC 10ETH in the Passive Routing Mode 5 1 1 Seiting a Virtual Port If the control application cannot work with an Ethernet driver download the Kramer VSPM from our Web site to set a virtual port for each local port
25. s there is data to be sent The data is always sent to a specific destination as defined by the Destination IP address and the Destination Port Number Settings of the FC 10ETH To configure the FC 10ETH to the Active mode connect it and do the following Press the Search button to find the device connected to the PC Set the IP address number according to your network requirements Select the Active Mode check box in the configuration manager Set the Destin IP and Port in the Destination Settings Area for CHANNEL 1 and CHANNEL 2 Press the Config button to accept changes gt 10ETH Configuring the FC 10ETH Ethernet Controller 5 1 FC 10ETH Controlling Machines via the Ethernet using the FC 10ETH i Controlling Machines via the Ethernet using the FC 10ETH You can use your FC 10ETH to control a Kramer or non Kramer RS 232 RS 485 machine e From computers that connect to a LAN as well as via an Internet connection see Section 5 1 e Via a controller as well as via an Internet connection see Section 5 2 Controlling a Machine via a Computer To control a Kramer machine via five computers as illustrated in the example in Figure 9 do the following 1 Connect the 12V DC power adapter to the power socket and connect the adapter to the mains electricity 2 Configure the FC 10ETH to the Passive routing mode see Section 4 4 1 3 Connect up to two machines that is connect the RS 232 COM 1 po
26. uting mode see Section 4 4 1 No Active checkbox is displayed for V2 devices The Passive Routing Mode for V1 and V2 Devices In the Passive routing mode the FC 10ETH never opens the Ethernet communication first and only replies to the connection requests coming from the active remote stations Serial data that is received at the serial port of the FC 10ETH before the remote station contacts the FC 10ETH is discarded In the Passive mode the FC 10ETH will work with any station on the network that contacts it but not more than five stations simultaneously three via COM 1 and two via COM 2 as the example in Figure 9 illustrates Configuring the FC 10ETH Ethernet Controller 13 4 4 2 To configure the FC 10ETH to the Passive mode connect it and do the following Only for V 1 devices because this is the default mode V 2 has no configuration 1 4 Press the Search button to find the device connected to the PC Set the IP address number according to your network requirements For V1 devices clear the Active Mode check box if selected in the configuration manager This does not appear for V2 devices Press the Config button to accept changes The Active Routing Mode for V1 Devices Only In the Active routing mode V1 devices only the FC 10ETH does not wait for the remote station to send the connection request first it sends the connection request and routes the data in the destination device direction as soon a

Download Pdf Manuals

image

Related Search

Related Contents

Little GIANT 505350 Instructions / Assembly  CP62 Datasheet - Mouser Electronics  Guía de configuración rápida  Guida dell`utente - Old Organizers Collection  Instruções de utilização  Hotpoint TS16BCR Refrigerator User Manual  Les facteurs internes à la coopération, influencent-ils l`activité  Base de restauration postérieure fluide à placement en masse  Manuale Uso e Manutenzione Sistema Blocco  3208 - Notice adoucisseurs NSC14-17-25ED  