Home

QFHPN High Power Optical Node Installation

image

Contents

1. Enhance HFC QFHPN High Power Optical Node with AGC Installation amp Operation Manual Although every effort has been taken to ensure the accuracy of this document it may be necessary without notice to make amendments or correct omissions Specifications subject to change without notice HFC Enhance is a registered trademark of ATX in the United States and or other countries Products or features contained herein may be covered by one or more U S or foreign patents Other non ATX product and company names in this manual are the property of their respective companies TABLE OF CONTENTS 1 IMPORTANT SAFEGUARDS 0 200 eee hh nan 1 1 2 INSTALLATION AND OPERATION eeeeee hh hn 2 1 2 1 IfiStallatiOn x x aee etes EXTR rb IE Roe Re ele MOE PaO Ga eRe 2 2 2 2 MO Unt G PEPPER TP LI 2 2 2 3 Grounding i cst shee en e e irent eec LLL UM DUE cp E 2 2 24 Connecting COAX i ciseoc br RE pere dx end mend xg Re d 2 2 2 5 Connecting Optical Fibers 0 006 cee 2 2 3 POWER UP AND TEST ose cia dues saad 3x kae TRADE XT QR ER Roh CR RU n 3 1 3 1 Connect the Power Adapter auaa 00 00 cece eee 3 1 3 2 Nerify Signal Levels iiia racer ecu A qup rie eed 3 1 3 3 Fine tuning the Compact Node to the RF Network 3 2 3 4 Changing the RF Attenuation llli 3 2 3 5 Changing the RF Equalization 0 00 0 cece eee 3 2 4 SPECIFICATIONS oerinoar ga
2. ENGTH OPTICAL OUTPUT POWER RETURN PATH RF INPUT POWER 22 to 35 dBmV FREQUENCY RESPONSE 0 75 dB 5 42 MHz RF TEST POINT 20 dB referenced to input ELECTRICAL amp ENVIRONMENTAL RF FREQUENCY 5 42 MHz DC POWER 5 8 VDC AC POWER ADAPTER DC POWER INPUT RANGE OPERATING TEMPERATURE DIMENSIONS 1 42 H x 6 43 W x 5 45 D 3 6H x 16 3W x 13 8D cm WEIGHT 1 1 Ibs 0 5 kg TOTAL POWER CONSUMPTION lt 6 5 watts HFC Enhance QFHPN High Power Optical Node with AGC Installation amp Operation Manual 4 1 CHAPTER 4 SPECIFICATIONS This page intentionally left blank 4 2 HFC Enhance QFHPN High Power Optical Node with AGC Installation amp Operation Manual CHAPTER 5 SERVICE amp SUPPORT SERVICE amp SUPPORT 5 5 1 5 2 Service amp Support Contact ATX Networks Please contact ATX Technical Support for assistance with any ATX products Please contact ATX Customer Service to obtain a valid RMA number for any ATX products that require service and are in or out of warranty before returning a failed module to the factory TECHNICAL SUPPORT Tel 905 428 6068 Toll Free 800 565 7488 USA amp Canada only gt Press 3 for Technical Support gt Then press 1 for Digital Video Products DVIS DigiVu UCrypt etc gt OR press 2 for All Other Products Email digitalvideosupport atxnetworks com for Digital Video Products Email jleskovar atxnetworks com for All Other Produc
3. a desired value 4 Click the return button to set the attenuation value into memory The display stops blinking The RF output level has now been changed and set Changing the RF Equalization The Equalization feature allows you to change the tilt on the RF output to compensate for the losses in the coax cable High frequency channels tend to be attenuated by the cable more than the low frequency channels Changing the tilt attenuates the lower channels but not the high channels to overcome the cable loss issues The attenuation can be applied in 1dB increments up to a maximum of 16 as follows 1 Using the arrow button select the EQ mode The current tilt setting will be displayed 2 Press and hold the return button until the display starts to blink 3 Use the arrow buttons to change the value shown on the blinking display to a desired value 4 Click the return button to set the equalization value into memory The display stops blinking The RF tilt has now been changed and set HFC Enhance QFHPN High Power Optical Node with AGC Installation amp Operation Manual CHAPTER 4 SPECIFICATIONS SPECIFICATIONS 4 Specifications SPECIFICATIONS QFHPN RECEIVER Forward Path WAVELENGTH OPTICAL INPUT POWER RANGE FREQUENCY RANGE FREQUENCY RESPONSE 40 44 dBmvV at 0 dBm optical input RF ATTENUATION CARRIER TO NOISE RATIO COMP 2nd ORD COMP TR BT RF TEST POINT TRANSMITTER Optional Return Path WAVEL
4. ect the values you want to view as follows Check RF Power Output Level Use the arrow control buttons to select the RF LEV mode When the compact node completes its initial diagnostics it will automatically be selected The display indicates the RF output power measured in dBmV Ch Note that the attenuation setting will directly affect the output power value for the compact node Using an RF Signal Meter confirm the RF downstream power level output The output level should be approximately 40dBmV per channel with an optical input of from 8 to 1dBmV o gt The RF level can also be measured from the RF output test port The level at the test port will be approximately 20 dB below the actual RF output level Check Optical Power Receive and Optical Output Levels Use the arrow control buttons to select the OP IN OUT mode Both the input and the output optical power levels can be viewed Enter the OP IN OUT mode by pressing the down arrow and the display shows the optical input power from the network The value on the display is shown in dBm and should be between 9 and 1 The ideal setting is 3 Pressing the down arrow button again shows the upstream optical output power level being generated by the compact node also measured in dBm This value should measure between 0 to 2 Using an Optical Power Meter verify that the downstream forward path signal on the fiber cable coming from the head end is between 9 and 1 dBm Usin
5. g an Optical Power Meter verify the upstream output of the compact node return path is between 0 and 2dBm QFHPN 2W only Check the Upstream RF Power Level QFHPN 2W only The compact node has no direct measurement of the upstream RF power it is receiving You will need to confirm the received RF power from a cable modem at the head end or at the RF test port on the CATV compact node e Using an RF Signal Meter verify the RF input to the compact node is between 23 dBmV and 35dBmV The measurement at RF upstream input test port will be 20 dB below the actual input level HFC Enhance QFHPN High Power Optical Node with AGC Installation amp Operation Manual 3 1 CHAPTER 3 POWER UP AND TEST 3 3 3 4 3 5 Fine tuning the Compact Node to the RF Network In some cases the output of the compact node may need to be adjusted The compact node has built in attenuation and equalization features that allow you to optimize the system Changing the RF Attenuation The attenuation feature allows you to reduce the RF output into the coax network in the case where overdriving is being experienced Attenuation can be applied in 1dB increments up to a maximum of 16db as follows 1 Using the arrow button select the ATT mode The current attenuation setting will be displayed 2 Press and hold the return button until the display starts to blink 3 Use the arrow buttons to change the value shown on the blinking display to
6. nting screw slot 9 Control buttons 10 3 digit Status display 11 Power ON alarm LED 12 Mode LED RF LEVEL power 13 Mode LED Optical in out power 14 Mode LED Attenuation settings 15 Mode LED Equalization settings tilt 7 Figure 41 QFHPN 2 way Compact Node 13 12 11 10 9 Downstream RF output port 1 Downstream RF output port 2 Downstream fiber input Power input 5 8VDC Grounding lug and screw Mounting screw slot Control buttons 3 digit Status display Power ON alarm LED 10 Mode LED RF LEVEL 11 Mode LED Optical in out power 12 Mode LED Attenuation settings 13 Mode LED Equalization settings tilt oouoostowmwzi l 4 Figure 2 QFHPN 1 way Receive Only Compact Node HFC Enhance QFHPN High Power Optical Node with AGC Installation amp Operation Manual 2 1 CHAPTER 2 INSTALLATION AND OPERATION 2 1 Installation The ATX Networks QFHPN compact node is designed to operate in a utility room or closet It must be placed in a location where it will not be directly exposed to liquid or to extreme temperatures Please refer to Figure 1 or Figure 2 above depending on model being installed for installation and operation 2 2 Mounting The compact node is designed to be mounted directly on a wall or other indoor surface It should be placed so an operator can view the status display for installation or troubleshooting Attach the compact node to a wall board with the connectors facing downwa
7. rd Use appropriate mounting hardware not included for the surface you are mounting it on The slots on the compact node will accommodate screw type fasteners from sizes 8 to 12 2 3 Grounding The compact node should be grounded to electrical utility ground using at least 10 solid ground wire This will minimize the risk of electrical shock and minimize the effect of noise on the coax cable inside the building Follow all electrical codes and standards that apply when installing this equipment 2 4 Connecting COAX Connect the building video coax wire to the output of the CATV compact node For best results the building should use RG6 coax cable or better with as short of runs as possible The compact node is designed to output 40dBmV of RF power 44 dBmV x2 on QFHPN D44 and includes the ability to compensate for long distance coax runs if long runs cannot be avoided Be sure that all electrical couplers are of the 2 way type or poor performance will result with cable modems and some set top boxes When attaching the coax cable to the CATV compact node use appropriate tools do not over tighten or you may damage the node A loose or damaged coax connection may also result in poor signal stability as temperature changes over time 2 5 Connecting Optical Fibers CAUTION NEVER look into the ends of a fiber optic cable that is connected to the network Communications systems use lasers that emit invisible infrared light which can do permanent damage
8. t node units may emit harmful invisible laser radiation if powered on and the case is opened or the beam path is exposed The ATX Networks QFHPN compact node is classified as Class 1M per IEC EN 60825 1 A2 2001 This product complies with FDA CDRH 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice No 50 dated 26 July 2001 Viewing the laser output with certain optical instruments for example eye loupes magnifiers and Miniscopes within a distance of 100 mm may pose an eye hazard Laser power up to 26 mW at 1310 nm could be accessible if optical connector is open or fiber is broken Lasers are Powered ON whenever the unit is powered A CAUTION Use of controls adjustments and procedures other than those specified herein may result in hazardous laser radiation exposure HFC Enhance QFHPN High Power Optical Node with AGC Installation amp Operation Manual 1 1 CHAPTER 1 IMPORTANT SAFEGUARDS This page intentionally left blank 1 2 HFC Enhance QFHPN High Power Optical Node with AGC Installation amp Operation Manual CHAPTER 2 INSTALLATION AND OPERATION INSTALLATION AND OPERATION 2 Installation and Operation 15 14 13 12 11 10 1 Downstream RF output level test port 20dB 2 Downstream RF output Upstream RF input 9 3 Upstream RF test port 20dB 4 Power input 5 8VDC 5 Upstream fiber output 6 Downstream fiber input 8 7 Grounding lug and screw 8 Mou
9. te ate ah aes 9 X Rcg ICE RUE Swale a ee dares or 4 1 5 SERVICE amp SUPPORT 0 ccc ccc eee hh hn 5 1 5 1 Contact ATX Networks 0 0 0 0 0 cc eee eee 5 1 5 2 Warranty IntormallOn used mex Rafa UE EE eee reat ER 5 1 HFC Enhance QFHPN High Power Optical Node with AGC Installation amp Operation Manual This page intentionally left blank HFC Enhance QFHPN High Power Optical Node with AGC Installation amp Operation Manual CHAPTER 1 IMPORTANT SAFEGUARDS IMPORTANT SAFEGUARDS 1 Important Safeguards ATX Networks strongly advises you to read the following safety instructions prior to installing and operating this equipment e Read These Instructions First All safety and operating instructions should be read before installing or operating this equipment e Retain This User Manual Safety and operating instructions must be retained for future reference e Ventilation The optical node should be kept at a distance from other objects to keep from overheating Maximum operating ambient temperature is 131 F 55 C e Power Sources The mains circuit should be a dedicated un switched supply Keep the unit away from high voltage or other interference creating devices such as motors compressors etc A CAUTION For continued protection against risk of fire replace circuit breakers fuses if necessary with one of only the same type and rating A OPTICAL OUTPUT SAFETY Optical compac
10. tical network jumper Insert the forward path fiber into the correct connector and confirm that the cable snaps into place Clean and inspect the upstream return path connector on the compact node and connect the return path fiber jumper Confirm that the return path connector snaps into place QFHPN 2W only 2 2 HFC Enhance QFHPN High Power Optical Node with AGC Installation amp Operation Manual CHAPTER 3 POWER UP AND TEST POWER UP AND TEST 3 3 1 3 2 3 2 1 3 2 2 3 2 3 Power Up and Test The compact node is now ready for power up Connect the Power Adapter Insert the 5mm power plug from the power converter into the power port of the compact node and plug the adapter into the 120VAC wall outlet The compact node will conduct a self test and the power LED will be flashing As the test proceeds each of the mode LEDs are lit in sequence When the self test is complete the output power LED is lit and the display shows the current RF output power level A green power LED indicates that the unit is operating correctly and the RF output is within acceptable limits See alarm indicator section if the SYS ALARM LED is not showing green Secure the low voltage cable from the compact node such that it does not become easily tangled or dislodged Verify Signal Levels The compact node is equipped with a built in power meter for the RF output and the optical input outputs Use the arrow control keys to sel
11. to your eyes Other general recommendations e Use only Single Mode Fiber SMF optic cable 9 125yuM Multi Mode Fiber MMF is incompatible with the equipment and will result in unacceptable performance and possible damage to the equipment e All fiber splices should be fusion type splices Avoid mechanical or compression type connections e nsure that you follow local practices when working with fiber optic cable as tight bends or excessive pulling on the fiber jumpers may damage the cable e For optimum performance fiber runs should be made directly from the transmitter to the receiver Minimize the use of adapters patch panels and additional points of failure and signal loss e n order to ensure return loss is maximized use only SC APC connectors Clean and inspect connectors and fiber end faces prior to installation and every plug in out cycle e Use only industry approved methods materials and solutions for cleaning Donotturn on the transmitter alone or without a protector cover at the unit connector end otherwise the laser can do harm especially to eyes This is especially critical because the laser is invisible Always turn off the laser prior to making connections to the transmitter Failure to do so may cause irreparable damage to the laser and transmitter Attaching the fibers to the CATV compact node Before connecting the optical fiber to the CATV compact node inspect and clean the optical connector before connecting the op
12. ts CUSTOMER SERVICE ATX Networks 1 501 Clements Road West Ajax ON L1S 7H4 Canada Tel 905 428 6068 Toll Free 800 565 7488 USA amp Canada only gt Press 1 for Customer Service Fax 905 427 1964 Toll Free Fax 866 427 1964 USA amp Canada only Web www atxnetworks com Email support atxnetworks com Warranty Information The ATX Networks QFHPN has a one year warranty and is subject to ATX Networks standard warrantee terms There are no user serviceable components inside the unit The warranty is void if the unit is opened or is damaged due to misuse HFC Enhance QFHPN High Power Optical Node with AGC Installation amp Operation Manual 5 1 1 501 Clements Road West Ajax ON L1S 7H4 Canada ATX Tel 1 905 428 6068 Toll Free 1 800 565 7488 Fax 1 905 427 1964 Toll Free Fax 1 866 427 1964 www atxnetworks com support atxnetworks com Rev 11 15 ANW1004 Printed in Canada