Home
USER MANUAL/Installation Instructions TV-22 with 12
Contents
1. Sierra Ra l DENTAL PRODUCTS LLC USER MANUAL lnstallation Instructions TV 22 with 12 gallon VAS Tank 8 Low Voltage Controller 1931 W Gulf to Lake Hwy Lecanto FL 34461 800 240 5677 FAX 352 513 4801 Email Sierradentalproducts Outlook com Website WWW dentalvacuums com TABLE OF CONTENTS PELL TeL AOAN EO ETE Congratulations Customer support Warranty Policy Specifications Site requirements Product specifications Tank Specifications Chassis Specifications System layout E 0 Installation Operation Plumbing flow diagram Maintenance Troubleshooting 0 CONGRATULATIONS On the purchase of your Dual TRU VAC Dry Vacuum System This state of the art dry vacuum is a very powerful high volume efficient system With the benefit of 2 motors for complete backup recovery 230 volt motors provides plenty of vacuum on demand while maintaining multiple operatories Equipped with the Vortex Action Separator Tank VAS your dual TRU VAC dry vacuum system will ensure efficiency reliability and savings of up to 200 000 gallons of water usage per year Sierra Dental Products LLC www dentalvacuums com Sierra RANI DENTAL PRODUCTS LLC CUSTOMER SUPPORT We will be happy to help you with any questions or concerns you may have about your TRU VAC SYSTEM CONTACT US 24 HOURS A DAY 7 DAYS A WEEK Sierra Dental Products LLC 1931 W Gulf
2. WS ELBOWS Minimum Drain 1 flex pipe or 1 flex pipe or Line 1 Sched 40PVC 1 Sched 40 PVC 1 Schedule 40 PVC is recommended for main feed SUCTION lines running to operatories from the TRU VAC PRODUCT SPECIFICATIONS ELECTRICAL Voltage Operating Load Startup Load Frequency VAS TANK Max Operators Capacity ENVIROMENTAL CONDITIONS MAX Operating Temp Storage Temp Relative Humidity Cooling Fan DUAL TV 22 230 V AC 10 amps X2 14 amps X2 50 60 Hz DUAL TV 22 12 gallons 214 101 C 0 150 18 66 C 90 no condensation 115V AC Flammable anesthetic mixtures should not be located anywhere around this unit 1 TANK SPECIFICATIONS Frank weight eit wrath Depth cacy V A S 43 lbs 40 17 15 12 Gal 0 z O gt 2 a 0 8 0 0 I O z a 34 21 20 188lbs 2015 7 I ZE Hi LILIES SPS SSD IDES OSS a CESSES ESAS SS A ALAA ASS S SS FISIS DS POLONA SSIS ISS 34 20 10 SYSTEM LAYOUT TV 22 A Low Voltage Out To Operatories Controllers Vacuum Gauge Power Cord 1 2 3 HP 230 VAC 1 Motor Cooling Fan Check Valve Drain 115 VAC 1 PVC 11 INSTALLATION TV 22 1 You can mount your motor assemblies on top of each other
3. d a return material authorization RMA number must be obtained from Sierra Dental Products Returned units must be properly packaged for shipping We are not responsible for shipping damages or shipping charges Sierra Dental Products will at their discretion repair or replace defective parts Note there is a 25 re stocking fee on all returns SAFETY Use of the TRU VAC not in compliance with the instructions specified in this manual may result in permanent failure of the unit WARNING To prevent fire or electrical shock do not expose this unit to rain or moisture excessive heat or improper ventilation ATTENTION USERS Alerts users of important operating and maintenance instructions Read carefully to avoid any problems Warns users of a potentially hot surface and a danger of burns Warns users that uninsulated voltage is present and can cause electric shock SUB ASSEMBLIES Low Voltage Controller Vortex Action Separator VAS TANK Motor Assembly Motors tanks and controllers may be ordered separately 6 SPECIFICATIONS SITE REQUIREMENTS ELECTRICAL 230 8 SINGLE TV 12 DUAL TV 22 115 VOLTS Maximum Circuit 15 amp 15 amp Qty 2 Breaker Rating Or 30 amp Minimum Wire Size 14 gauge 14 gauge Qty 2 Or 8 gauge PLUMBING SINGLE TV 12 DUAL TV 22 Minimum Exhaust 1 steel pipe 1 steel pipe Vent Pipe DO NOT USE ANY DO NOT USE ANY 90 DEGREE 90 DEGREE ELBO
4. ding Wherever the exhaust leaves the building assure that outside elements such as rain snow amp or foreign debris cannot make its way into the exhaust This could potentially cause harm to the motor The easier the exhaust can flow out of the motor with minimum restriction the cooler the system will run This will prolong the life of the motor Keep this in mind when routing the exhaust excessive length and multiple turns will create more restriction 15 CONT INSTALLATION TV 22 A a 9 Route and connect the motor assembly power cord to a 230 colt source maximum circuit breaker rating 15 AMPS per motor FIG 6 Figure 6 8 SUPPLIED BY CUSTOMER BLUE WIRE one leg of 230 GREEN WIRE ground WHITE WIRE ground Connections are to be made by a certified electrician On the underside of the low voltage controller you will find three remote wires Red white amp blue Route these wires to a location were you will be mounting a remote switch to control the system Red 28 Volt power Blue Return White Illumination Lamp REMOTE WIRES 16 OPERATION Turn the toggle switch to the up on position to turn the pump on Or to down on Use the red rocker switch to turn the controller on amp off position is used to control the pump on off with a remote switch If the system will not turn on Always check this fuse first Only replace with 2 5 a
5. ers are to be mounted chair side in the operatory on the main line that feeds your HV lines and saliva lines Multiple fittings included with the product ensures an easy installation process These filters are a key in preventing contamination of bio hazardous waste in our water systems These filters can be easily removed recycled and replaced REPLACEMENT FILTERS available in packs of 3 Filters are a very important factor with your TRU VAC A dirty filter can cause loss of vacuum and motor damage Inspecting and replacing these filters ensures proper maintenance procedures and avoids down time or costly repairs
6. is recommended CONT INSTALLATION TV 22 REFER TO THE PLUMBING ILLUSTRATION 5 The RED outlined area shows the correct positioning for plumbing the motors together The BLUE outlined area shows a 90 elbow this will only be used if your VAS tank is mounted beside the two motor assemblies If this is the case then you will cut a section of flex hose that can reach from the motor inlet to the tank inlet Slip the yellow nipples in the hose ends and be sure to tighten these down with the provided hose clamps This will be the connection between your motors and your VAS tank f your system will have the VAS tank mounted above the two motor assemblies DON T use the 90 elbow Cut a big section of flex hose that can reach from the motor inlet to the tank inlet Slip the yellow nipples in the ends and be sure to tighten these down with the provided hose clamps This will be the connection between your motors and your VAS tank 14 CONT INSTALLATION TV 22 dh 6 Connect the preexisting operatory lines to the tank Fig 4 Unless you plan to run all new lines 7 We provide a 1 steel pipe exhaust Fig 5 route your exhaust with this same material or a FIG 5 heat flexible pipe to and outside vent DO NOT USE A 90 ANGLE 45 ANGLES ARE RECOMMENDED 8 Routing the exhaust to an outside vent is very important this reduces the heat significantly Also this will ensure that any odor will leave the buil
7. mp fuse 17 CONT OPERATION A For use with an alternate remote switch ensure that the red rocker switch is on and the toggle switch is in the down remote position this will allow you to control the system with a remote switch 18 PLUMBING FLOW DIAGRAM MAINTENANCE ALWAYS make sure that your filter is WHITE amp CLEAN a bi weekly check is highly recommended These micron filters are not reusable do not attempt to clean or alter the filterin any way Dirty filters should always be replaced with new ones every 3 6 months New filters can be purchased thru Sierra Dental Products LLC Contact us via phone email or visit us on the web FILTER Other than filter raplacenient your new TRU VAC is virtually maintenance free with its reliable oil less amp water less pump Your TRU VAC should be mounted in a clean environment dust and debris can potentially harm your unit and cause malfunction not covered under warranty The Vacuum relief valve pulls air from the environment so dust and debris can freely enter the motor if it is mounted incorrectly DO NOT ATTEMPT TO ADJUST THE VACUUM RELIEF VALVE The vacuum relief valve is a preset part Sierra Dental Products LLC has set the standard for this valve according to many variables Adjusting the vacuum relief valve will void your warranty Intermittently check to ensure that your cooling fan is still running If it is not on while the motor is running c
8. ontact us Intermittently check your drain connection on the bottom of the VAS tank to ensure that it is dry and not leaking 20 TROUBLESHOOTING NO SUCTION a Pump notturnedon a Turn pump on b Pump not running b Contact Sierra Dental c VAS tank is full Products LLC d Drain check valveis c Shut unit off for 20 clogged seconds and turn it back e Clogged drain on f Kinked or collapsed d Contact Sierra Dental suction hose Products LLC e Call your Local Plumber f Call Sierra Dental Products LLC Poor Or Low a Restricted air a Ensure that exhaust is Suction exhaust ran according to b Restricted air suction installation procedure Call Sierra Dental Products LLC b Dirty Filter Contact Sierra Dental Products LLC Pump Does a 230 Volt Circuit a Turn the circuit breaker Not Run breaker is OFF ON b Remote switch is OFF b Make sure your remote or not correctly is ON Contact Sierra connected Dental Products LLC c Electrical Problem c Call Sierra Dental Products LLC Feel free to contact us for any troubleshooting issues ACCESSORIES BIO PURE Complete evacuation system cleaner 100 Guaranteed to maintain suction amp eliminate trap hand cleaning This is an all natural proprietary microbial formula designed to eliminate odors amp digest organic waste HIGHLY RECCOMENDED CHAIRSIDE AMALGAM SEPARATOR These filters are designed to collect amalgam before it makes it to the drain These filt
9. to Lake Hwy Lecanto FL 34461 Call us 1 800 240 5677 TOLL FREE Karen Bennett 352 527 1975 ADMINISTRATOR Chuck Bennett 603 897 5042 OPERATIONS MANAGER Dave Rolerad 603 493 3635 DIRECTOR OF MATERIAL Matthew Ball 352 208 7317 Mgr TECH SUPPORT Hayden Tucker _ 916 330 7191 SALES MANAGER Email us Sierradentalproducts outlook com Visit us on the web www dentalvacuums com https www facebook com sierradentalpumps Sierra DENTAL PRODUCTS LLC WARRANTY POLICY Sierra Dental Products Limited Warranty Warranty for the TRU VAC Dry Vacuum System is limited to the original purchaser of the unit Sierra Dental Products is only obligated under this warranty to the repair or replacement of defective parts or materials The defect s must be reported to Sierra Dental Products within the valid warranty period Sierra Dental Products will examine the product to determine if the parts are defective Products that have been abused neglected or damaged by being improperly installed maintained are not covered by this warranty We are not responsible for work performed on the unit by any unauthorized service agents Warranty Period Warranty is valid only with the return of the warranty card within 30 days of purchase for a period of 10 years Warranty Service and Return Policy To obtain warranty service product must be returned to Sierra Dental Products for examination at the purchaser s expense All returns must be authorized an
10. with the VAS tank above or beside it optional Placement is all according to your specific location dimensions Contact us if you have any difficulty or concerns regarding installation The VAS tank can be installed in an alternate area if necessary 12 CONT INSTALLATION TV 22 1 Find a location that fits the required site specification 2 Whereveryou plan to mount motor assemblies be sure that 230 volt power source is readily available 3 Place your motor assemblies on the ground if the VAS tank is going to mounted on top of the motor chassis do so now Align the 2 holes on tank base to the 2 holes on motor chassis and secure with included hardware 4 Run PVC Flex Pipe from the top of the tank Fig 1 into the motor inlet Fig 2 See illustration for plumbing on the following page 5 Plumbing will be according to whether you mount the tank above or beside the motor assemblies All of the necessary plumbing is provided for you The difference between the 2 plumbing configurations is only the length of the flex pipe that makes the connection between the tank and the motor inlets NOTE required hoses clamps and adapters provided ALTHOUGH SCHEDULE 40 PVC MAY BE NEEDED FIG 2 Connect a proper drain to the bottom of the tank and route this to the sewer Assure that the tank drain is at a higher elevation than the sewer inlet to allow the tank to drain properly 1 Schedule 40 PVC
Download Pdf Manuals
Related Search
Related Contents
m68em05x4 emulator module user`s manual HDDを取り外す際のご注意 Smarty - Nordpeis SG BIGLUNAR SELIWEB Manuel d`installation Kensington SlimBlade Media Mouse, Black Samsung 730B User Manual TS-590S KENWOOD NETWORK COMMAND SYSTEM Setting Manual Untitled - Login frtx400h-fj™ user`s manual Copyright © All rights reserved.