1. eco dir www eco adir org TWO POSITION HEPA AIR PURIFIER WITH REMOTE CONTROL MODEL ECO 68801 RC WITT Nn THANK YOU FOR CHOOSING THE ECO 68801 RC AIR PURIFIER BEFORE OPERATING PLEASE READ THIS INSTRUCTION MANUAL Important Safety Instructions WARNING This appliance is intended for use in a domestic amp commercial environment only Any other use is not recommended by the manufacturer and may cause fire electrical shocks or other injury to person or property When using electrical appliances basic safety precautions should always be followed 1 Always operate the product from a power source of the same voltage frequency and rating as indicated on the product identification plate 2 Close supervision is necessary when any product is used by or near children Do not allow children to use it as a toy 3 Do not operate any product with a damaged cord or plug or after the product malfunctions is dropped or appears damaged in any way 4 To reduce the risk of electrical shocks do not expose the unit or flexible cord to moisture of any sort 5 Switch off and unplug from the power socket when not in use before assembling or changing filters and before cleaning 6 Do not place objects on the product or allow objects to obstruct the inlet or outlet openings or operate in close proximity to walls or curtains etc 7 The use of attachments or accessories not recommended or sold by the product distributor sh
2. ect ION button if ioniser is required 4 Press Timer to select required run duration 5 Press Power button to turn on or turn off Please note your air purifier can be operated lying down or upright depending on your chosen location 1 Side grid unfiltered air comes in through inlet 2 Pre filter collects large sized dust particles in air Scent Cartridge Fitting Press the scent cover 6 and insert CAUTION DISCONNECT FROM POWER SUPPLY BEFORE the cartridge after removing pull CLEANING cover Press again to close The unit can be used without scent if 1 Remove the dust from the ion outlet with dry brush as required preferred Please note that for the 2 Clean the pre filter with water every 2 months to remove dirt small number of asthmatics who are and odour replace with it is completely dry sensitive to perfumes etc they may have a similar reaction with the scent cartridge These people should use Mig the scent cartridge with caution a Replacement Filters e Replacement filters are available from our Help Desk on 020 8459 2458 e Replacement scent cartridges are available from our Help Desk on 020 8459 2458 Technical Data Product Disposal Information Concentration of anion 1 5 x 210 ions cc or above Do not mix products bearing the crossed out bin symbol below Air cleaning rate 290 with your general household waste For the correct collection Air flow H 3m s M 2m s L 1m s C E and
3. erminal which is marked with the letter E the earth symbole coloured GREEN OR GREEN YELLOW 4 Always ensure that the cord grip is positioned and fastened correctly lf a 13A BS 1363 fused plug is used it must be fitted with a 13A fuse If in doubt consult a qualified electrician Wiring for a 13 Amp Plug BS1363 Neutral N Blue Brown Three functions in one It can be used as air purifier ionizer and air fragrance to improve the air quality in office or home Efficiently cleans the air Using negative ion and multi layer HEPA filters to collect dust it can reduce indoor air pollution caused by pollen suspended particles hairs germs harmful gases formaldehyde smoke other odours and transportation of pollution Three speed settings set in high speed H to clean room air rapidly then turn to medium speed half an hour later to keep the air fresh and clean Use extra quiet low speed at night Safe It is safe and reliable with an auto shut off function There are 3 time setting modes and related indicator lights Function Guide loniser outlet Fresh air outlet Fragrance compartment optional Digital status display Air intake Time program button TIMER Speed control selector SPEED loniser function on off ION On off button POWER Each of the unit s function can be fully controlled via wireless remote 3 HEPA filter white stops small particles coming through with h
4. igh efficiency sterilizing and dust collection function 4 Activated carbon filter black absorbs smoke and odours 5 Tio2 coated photocatalyst filter grey kill germs bacteria and virus 6 Scent cover scent comes from the outlet 7 Upper cover emits clean air from outlet control The function keys include 1 Power loniser on off ION N Low speed iN Medium speed O1 Note HEPA means High Efficiency Particulate Air Two Position HEPA Air Purifier O 8 Hour time setting N 4 Hour time settin i You can use your Air Purifier upright as shown in diagram or lying down on its back whichever suits your chosen location 0 High speed 2 Hour time setting Remote control required 2 AAA 1 5V batteries not included Operation Guide Note Batteries contain materials which are hazardous to the environment 1 Remove cover 1 Replace pre filter and cover Your they must be removed from the appliance at the end of their life and filters will need replacing every 6 12 months depending on the disposed of safely environment and frequency of use On the filter there is a space for you to write the date you inserted into the unit The HEPA filter will go from white to a dark grey when it will need changing 2 Connect to power outlet and press Power button The default speed setting will be medium Manually select high or low if required 3 Manually sel
5. ould not be used 8 Do not attempt to disassemble the unit other than to replace filters or scent cartridge 9 Do not place the unit on a metal surface 10 Ensure the unit is placed on a firm level surface before operating 11 Do not use the unit in artificially hot or humid conditions or use in any hazardous environment 12 Do not clean the machine with organic solvent 13 Place the unit 90cm above floor level for best performance The unit should never be used at floor level if the room is carpeted 14 Set in high speed to clean room air rapidly and then turn to lower speed half an hour later When used at night set the speed at lower grade to keep the air fresh and clean 15 Do not wash the filter cartridge HEPA The cartridge is not washable and doing so will cause damage BS Plug Wiring Wiring Instructions Should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code BLUE NEUTRAL BROWN LIVE As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug proceed as follows 1 The BLUE wire is the NEUTRAL and must be connected to the terminal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 NEITHER WIRE must be connected to the t
6. to and does not affect your statutory rights For further information please contact 020 8459 2458 This product has been manufactured to comply with the EEC Directives73 23 EEC and 89 336 EEC Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice EcoAir 09 09 ys
7. treatment of these products take them to the collection points Input voltage 220 240V 50Hz designated by your local authority Alternatively contact the Rated power 40W retailer who sold you the product Working Environment Temperature 10 55 C 95 RH Net dimension 300 x 300 x 175 mm Net Weight 2 55kg Gross Weight 3 2kg 0 Effective area 15m oe ae eS Service amp Warranty e Do not operate any product with a damaged cord or plug or after the product malfunctions or is dropped or appears damaged in any way Return the complete product to the place of purchase for inspection repair or replacement e For your convenience record the complete Model Type Number located on the Product Identification Plate and the date you received the product below and attach your purchase receipt docket as proof of purchase e To ensure your product is covered by warranty the complete faulty product together with your purchase receipt should be returned to your retailer ONE 1 YEAR LIMITED WARRANTY SAVE THIS WARRANTY INFORMATION EcoAir guarantees this product free from defects in materials and workmanship for a period of one 1 year from the date of purchase This unit must be operated under conditions as recommended at voltages indicated on the unit Any attempts made to service or modify the unit will render this WARRANTY VOID The actual product may differ slightly from the illustration This warranty is in addition

Download Pdf Manuals

image

Related Search

Related Contents

libretto installazione, uso e manutenzione box  Honeywell XYR 5000 Wireless Temperature Transmitter User Manual  Pelco C2446M-D User's Manual  Deutsch - M&C TechGroup  1 - pdf.lowes.com  Kwikset 730PE 11P CP Installation Guide  403437-01 取表 [更新済み]  FUNAI EC313E TV VCR Combo User Manual    ノーマルフロントフォークディスクブレーキキット 取扱説明書  